




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、User Instructions:SE 1734 Point I/O Faceplates with Descriptions01/09 Rev 1The SE 1734 Point I/O Faceplates files allow you to quickly load, configure, and use preconfigured status and diagnostic displays or faceplates for 1734 Analog and Digital I/O using RSView or Factory Talk View SE Edition.The
2、pictures below show examples of the on-top status and diagnostic displays or faceplates for both digital and analog 1734 I/O modules. These displays can be launched from Goto buttons you configure. These faceplates give users the option of adding I/O text descriptions next to each discrete I/O point
3、 or analog channel.Digital Faceplate ExampleAnalog Faceplate Example1System CompatibilityThe faceplate files are compatible with: RSLogix5000 V15 or laterRSView or Factory Talk View SE Edition 4.0 or later.The latest RSView Studio SE Edition 4.0 patches may be found within the Rockwell Automation Kn
4、owledgebase at the following website/ Answer ID: /knowledgebaseAnswer ID: 35779NOTE: These instructions are for Distributed I/O on EtherNet/IP and Control Net but not Device Net.The following modules are compatible with these instructions.Digital1734-IA21734-IB21724-I
5、B41734-IB81734-IM21734-IV21734-IV41734-IV81734-OA21734-OB21734-OB2E1734-OB2EP1734-OB41734-OB4E1734-OB81734-OB8E1734-OV2E1734-OV4E1734-OV8E1734-OW21734-OW41734-OX2Analog1734-IE2C1734-IE2V1734-IR21734-IT2I1734-OE2C1734-OE2VGeneral Setup1) After downloading your file, the following folder will be creat
6、ed: SE_1734_Digital&Analog_Faceplate_Files. This file will contain all of the required files needed for configuring the 1734 I/O faceplates in your application.Logix Configuration1) Open existing Logix file with RSLogix50002) Add and configure the desired Point I/O modules2a.For distributed I/O, rig
7、ht click the appropriate 1769 EtherNet/IP or Control Net Port (or if using the L4x controller, right click on the 1768 Bus) and select “New Module”.b.For the L3x controllers skip to step 2f.c.For the L4x controller, select the appropriate 1768 EtherNet/IP or Control Net Communications module.d.Give
8、the new Communications module a name, a description and enter the correct chassis size. For an ENBT give the IP address. For a CNB give the node number.e.Right click the Communication module you just configured and select “New Module” to add the appropriate network adapter.3f.Select the appropriate
9、adapter module for the distributed I/O you are using.g.Give the new Adapter module a name, a description and enter the correct chassis size. For a 1734-AENT set the IP address. For a 1734-ACNR set the node number.h.Right click the Adapter module for the intended Point I/O and select “New Module”. se
10、lect the appropriate Point I/O module.Then4i.Enter a distinct module name and description.j.Repeat steps 2h-2i for all input and output Point I/O modules.RSView SE Configuration1) Open your existing RSView SE application that you wish to add the Point I/O faceplate to.2) Add the appropriate “SE_1734
11、-Ixx_Faceplate.gfx” or “SE_1734-Oxx_Faceplate.gfx” file to your displaysa.Right-click on Displays, and select Add Component into Application. Browse to the SE_1734_Digital&Analog_Faceplate_Files folder and select the faceplate GFX file that matches the module you wish to create a faceplate for.53)Ad
12、d the faceplate parameter file “SE_1734_Parameter.par” to your RSView SE application.a.Right-click on Parameters, and select Add component to application. Browse to the SE_1734_Faceplate_Files folder and select the “SE_1734_Parameter.par” file and rename as you would like see it in your application
13、and click Open button.b.Now open the parameter file that you just added and edit the “parameter tag name” to match your application. The “parameter tag name” needs to include the RSLinx Enterprise “Device Shortcut” name of your systems controller and the Logix “tag name” of the intended Point I/O mo
14、dule to monitor.6i.Double-click on the faceplate parameter file, and edit the “Device Shortcut” name (in this example it is CLX-L43) to match the Logix controller that was previously configured in your RSLinx Enterprise Communication Setup.#1=:CLX-L43Network_Adapter:1ii. Enter the desired Logix “tag
15、 name” of the intended Point I/O module to monitor.(For modules that are distributed, this tag name will be the name of the I/O adapter followed by a “:” and the slot location of the module, i.e., Network_Adapter:1.)Close and Save changes.#1=:CLX-L43Network_Adapter:1To add parameter files for additi
16、onal Point I/O modules, simply repeat steps a. and b above, creating a unique parameter name and assigning the associated “Device Shortcut” and Logix “tag name” for each module.Example: #1=CLX-L43Network_Adapter_2:1 (“Network_Adapter_2” represents another unique name for an I/O adapter on the networ
17、k and “:1” represents the module in slot 1.)74) Add text descriptions to the Device Faceplate I/O.Revision 2 of the Device Faceplates has been designed to allow users to add optional text descriptions next to each discrete I/O point or analog channel on the faceplate.a.Open your display you wish to
18、add I/O descriptions to.b.Right click on the display and open the “Object Explorer”.c.Browse under the “Manual_Group” to find each group of I/O data, called “Data_x_x_Group”. (For analog or low count I/O modules, the grouping or data group name may be slightly different.)d.Find the “Txt_Desc_x” text
19、 object for the desired I/O you wish to add a text description to.8e.Double click to open the Text Properties box and enter your description.f.Click OK to complete. Verify your text appears as desired.g.Repeat steps 4c-4f for each I/O point or channel.95)Create the display navigation to open the Point I/O Faceplates at runtime.a.b.c.On a desired graphic display, create a new button for each I/O module. Double-click the button you created to ope
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 20以內(nèi)乘法除法口算練習(xí)題目1000道可打印
- 20以內(nèi)乘法除法口算練習(xí)材料1000道可打印
- 20以內(nèi)乘法除法口算練習(xí)題本1000道可打印
- 20以內(nèi)乘法除法口算練習(xí)冊(cè)1000道可打印
- 西羅莫司洗脫鐵基生物可吸收冠狀動(dòng)脈支架植入豬冠狀動(dòng)脈研究
- 新HSK五級(jí)短文閱讀理解測試的答題策略研究
- 科技綠色化助力商業(yè)的可持續(xù)發(fā)展
- 科技如何改變教育行業(yè)的培訓(xùn)方式
- 電子商務(wù)與智能物流的未來合作模式
- 資產(chǎn)評(píng)估合作投資協(xié)議書(2篇)
- 公對(duì)公打款合同
- 抗生素種類歸納分類
- 01-BUFR格式應(yīng)用指南(試用版)
- 體育測量與評(píng)價(jià)04心肺功能的測量與評(píng)價(jià)
- 提高意識(shí)風(fēng)險(xiǎn)防范化解能力體會(huì)發(fā)言
- 2023年度危險(xiǎn)作業(yè)安全監(jiān)護(hù)手冊(cè)
- 馬克思主義哲學(xué)十講
- 催化材料智慧樹知到答案章節(jié)測試2023年南開大學(xué)
- 中國故事英文版哪吒英文二篇
- GB/T 9846.1-2004膠合板第1部分:分類
- GB/T 32685-2016工業(yè)用精對(duì)苯二甲酸(PTA)
評(píng)論
0/150
提交評(píng)論