![移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)_第1頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/21/5b3e0bac-12ec-47be-8b79-e1e44eb162f0/5b3e0bac-12ec-47be-8b79-e1e44eb162f01.gif)
![移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)_第2頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/21/5b3e0bac-12ec-47be-8b79-e1e44eb162f0/5b3e0bac-12ec-47be-8b79-e1e44eb162f02.gif)
![移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)_第3頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/21/5b3e0bac-12ec-47be-8b79-e1e44eb162f0/5b3e0bac-12ec-47be-8b79-e1e44eb162f03.gif)
![移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)_第4頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/21/5b3e0bac-12ec-47be-8b79-e1e44eb162f0/5b3e0bac-12ec-47be-8b79-e1e44eb162f04.gif)
![移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)_第5頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/21/5b3e0bac-12ec-47be-8b79-e1e44eb162f0/5b3e0bac-12ec-47be-8b79-e1e44eb162f05.gif)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
1、 移動本地光傳送網(wǎng)光纜線路工程施工技術(shù)要求(試行)一、 路由要求1、核對光纜路由的具體走向、敷設(shè)方式、防護措施、環(huán)境條件以及接頭的具體位置是否與設(shè)計一致。2、測試桿路的地面距離、桿位、桿長、桿型及桿上裝置,并核對基本桿距,基本桿距為50m。3、驗收時因環(huán)境變化而對原設(shè)計標準進行修改過地方,應(yīng)由設(shè)計單位提供相關(guān)的設(shè)計變更資料,建設(shè)單位予以確認。4、確認與其他建筑物保持必要的凈距,見下表:架空光纜線路與其他建筑物、樹木的最小凈距表名稱平行時交越時平行凈距(米)注垂直凈距(米)注街道4.55.5最低纜距地面胡同4.05.0最低纜距地面鐵路1.33h7.5最低纜距地面一般公路>205.5最低纜距
2、地面高速公路>404.5最低纜距地面房屋、建筑距脊0.6距頂1.5最低纜距屋脊或平頂河流1.0最低纜到最高桅桿頂市區(qū)樹木1.5最低纜距樹頂郊外樹木1.5最低纜距樹頂通信線路8.50.6雙方纜線間距電力線1KV10KV220KV110KV3154KV220KV4二、新設(shè)電桿的工藝標準1、洞深:見下表:水泥電桿桿洞洞深表桿長 (米)7.08.09.010.0洞深(米)綜合土、軟石1.41.51.61.7堅石1.01.11.21.3注:測量方法以斜坡洞的下沿為測量參照物。2、新設(shè)電桿及新設(shè)地錨埋設(shè)夯實:回土必須分層(30cm)夯實,培土高出地面1520cm,雜草、稀泥、凍結(jié)夾雪的土塊、大石塊不
3、得填入洞內(nèi),市區(qū)地段應(yīng)回土夯實,恢復(fù)路面。3、桿根加固裝置:應(yīng)符合部頒及設(shè)計要求。4、電桿垂直:桿路在直線段上不得有眉毛彎,S彎,桿根左右偏差小于5cm;桿梢與桿身應(yīng)垂直,前后左右傾斜不得超過1/3梢徑;角桿桿根向內(nèi)角內(nèi)移半個桿根,桿梢向外角傾斜510cm;終端桿向拉線方向傾斜1020cm。5、桿號編寫:桿號應(yīng)面向道路一側(cè),字體及大小整齊一致,位置應(yīng)符合規(guī)定,用黑油漆噴涂或書寫,無堆積或流散。具體的編號順序應(yīng)與設(shè)計一致。6、拉線及撐桿A、拉線程式及規(guī)格:直線段上每816根電桿設(shè)一組雙方拉線,每3264根電桿設(shè)一組四方拉線。在水田里可用H桿代替雙方、四方拉線。100m以上長桿檔需要裝設(shè)雙方拉線。
4、角桿及其設(shè)置見下表:角桿允許的最大角深表: 單位:米吊線及光纜吊掛條數(shù)1條吊線架12條光纜2條吊線架24條光纜3條吊線架36條光纜4條吊線架48條光纜角深輕、中負荷區(qū)12121212重、超重負荷區(qū)10101010注:角深超出以上標準時需改為終端拉線或另選路由。在水泥電桿上架設(shè)光纜,角桿拉線程式如下表:角桿拉線程式表負荷區(qū)拉線 吊線及光纜程式角深(米)1條吊線架12條光纜2條吊線架24條光纜3條吊線架36條光纜4條吊線架48條光纜輕、中3.51×7/2.21×7/2.21×7/2.62×7/2.23.67.51×7/2.21×7/2.6
5、1×7/2.21×7/2.62×7/2.67.6101×7/2.61×7/2.21×7/2.62×7/2.62×7/2.610.1121×7/2.61×7/2.21×7/2.62×7/2.62×7/2.6重、超重3.51×7/2.21×7/2.61×7/2.21×7/2.61×7/2.21×7/2.63.67.51×7/2.61×7/2.21×7/2.62×7/2.6
6、2×7/2.67.6101×7/2.62×7/2.61×7/2.61×7/3.02×7/3.010.1122×7/2.22×7/2.62×7/3.02×7/3.0對于不適宜裝設(shè)拉線的轉(zhuǎn)交桿,可考慮撐桿來平衡轉(zhuǎn)角張力。見下表:坡度變更桿平衡拉線裝設(shè)表拉線程式 坡度變更負荷區(qū)2/102.9/103/103.9/10超過4/10輕、中負荷區(qū)1×7/2.21×7/2.6重、超重負荷區(qū)1×7/2.21×7/2.6另選路由B、拉線方位與纏扎規(guī)格:角桿、撐桿拉線位置應(yīng)在
7、角的平分線上,雙方拉及順線拉分別和線路進行方向垂直及平行。具體安裝工藝按照部頒規(guī)范執(zhí)行; C、拉線距高比:拉線距高比宜等于1;小于0.75或大于2時應(yīng)調(diào)整拉線程式;小于0.75或大于2時均應(yīng)加大拉線程式。D、撐桿裝設(shè):距高比宜為0.6,不小于0.5,撐桿位置在外角平分線上。E、拉線抱箍位置:抗風拉線及防凌拉線抱箍裝設(shè)在吊線抱箍下方10Cm處,其他拉線抱箍裝在吊線抱箍上方1520Cm處。7、新設(shè)吊線A、吊線規(guī)格:應(yīng)符合部頒及設(shè)計要求。B、架掛位置:吊線架掛位置為原有吊線的另一側(cè)。在利用原有吊線加掛光纜時,改道新建地段吊線與原吊線位置相同。吊線抱箍位置為距桿頂3540cm。C、吊線終結(jié):終端桿或分
8、線桿裝設(shè)頂頭平衡拉線,一條吊線裝設(shè)拉線一條,二條吊線裝拉線二條,拉線程式應(yīng)比吊線程式大一級;吊線終結(jié)規(guī)格與7/3.0拉線上把規(guī)格一致。D、吊線接續(xù):具體工藝按部頒及設(shè)計要求執(zhí)行;E、吊線輔助線裝置:坡度變更超過桿距的10%小于20%,3.5m<角深<7.5m時內(nèi)角時用4.0F圍電桿作普通扎法;坡度變更超過桿距的20%、7.5m<角深<15m時用7/2.2輔助結(jié)。見下表:坡度、角深變更輔助結(jié)裝置表坡度變化桿>1/5桿距仰俯角輔助裝置7/2.2鋼絞線角桿內(nèi)角桿角深7.4m4.0F捆扎加固4.0F(明線普通扎法) 角深>7.5m輔助結(jié)裝置7/2.2鋼絞線F、長桿檔
9、輔助線裝置:長桿檔、長桿檔跨越、飛線跨越的劃分標準見下表長桿檔、長桿檔跨越、飛線跨越的劃分標準表 單位:米桿距(m) 類別負荷區(qū)標準桿距一般長桿檔長桿檔跨越飛線跨越輕506775100100.1150150以上中506075100100.1150150以上重40608080.1100100以上超重2537.55050.1100100以上根據(jù)長桿檔在掛設(shè)光纜后增加的自重、風壓、冰凌各項負荷,確定其加固措施如下:a)一般長桿檔及長桿檔跨越:吊線程式加大一級,長桿檔電桿裝設(shè)7/2.6頂頭拉線。長桿檔跨越桿上裝設(shè)7/2.2雙方拉線、7/2.6的頂頭拉線,加大吊線程式一級并向前、后各延伸一檔。b)飛線跨
10、越:對長桿檔、外角桿、坡度變化較大(大于1/5)的電桿上的吊線,采取加固措施,其加固措施見下表:長桿檔、長桿檔跨越、飛線跨越加固措施表種類加固要求加固措施備注長桿檔76-150m更換吊線程式(加大1級)7/2.6鋼絞線151-200m正付輔助線7/2.6正吊線7/2.6輔助線201及以上正付輔助線7/2.6正吊線7/3.0輔助線201及以上正付輔助線7/3.0正吊線7/3.0輔助線8、吊線垂度本工程吊線垂度 重、負荷區(qū)吊線 原始垂度標準吊 線 程 式7/2.2 7/2.67/3.0 懸掛電纜重量W(千米/克)W1.46W0.574W2.52W1.224W3.89W2.31垂度 (厘米) 桿距
11、(米) 氣溫 C0)253035404550253035404550253035404550-202.23.96.96.49.313.92.44.07.26.710.015.32.34.07.06.810.115.6-152.34.17.46.79.814.82.54.27.87.110.616.52.44.27.57.110.816.7-102.54.37.97.010.415.92.64.58.47.511.317.82.54.48.07.511.518.0-52.64.68.67.411.117.12.74.89.17.912.119.32.64.78.78.012.219.502.74
12、.99.37.911.918.52.85.19.98.413.020.92.85.09.48.513.121.252.95.210.28.312.720.13.05.410.98.914.022.82.95.310.39.014.123.2103.05.611.28.913.722.03.25.912.09.515.125.13.15.711.39.615.325.5153.26.012.59.514.924.13.46.313.410.016.427.63.36.212.610.316.728.0203.46.613.910.216.216.63.66.915.011.018.030.03.
13、56.714.011.118.230.9253.77.215.711.017.629.33.97.517.011.919.833.53.87.315.812.120.134.1304.07.917.811.919.432.44.28.319.113.021.837.04.08.017.813.222.237.5354.38.820.213.021.535.74.59.221.714.224.240.54.48.920.214.424.641.1404.79.822.814.323.839.34.910.024.515.726.844.34.89.922.815.927.344.8中負荷區(qū)吊線
14、原始垂度標準吊 線 程 式7/2.2 7/2.67/3.0 懸掛電纜重量W(千米/克)W1.82W1.224W3.02W1.82W4.15W2.98 垂度 (厘米) 桿距 (米) 氣溫 C0)253035404550253035404550253035404550-202.33.45.38.68.612.42.43.75.69.48.411.92.43.85.68.89.013.1-152.43.65.69.29.113.12.53.95.910.18.812.62.64.05.99.49.513.9-102.53.85.99.99.614.02.74.16.310.89.313.32.74.
15、26.210.110.014.8-52.74.06.310.610.115.02.84.36.711.79.814.22.84.46.610.910.615.802.84.26.711.510.816.03.04.67.212.810.415.23.04.77.111.811.317.053.04.57.112.511.517.33.14.97.714.011.116.33.25.07.612.812.118.4103.24.87.713.712.318.73.35.28.315.411.817.63.45.38.114.012.920.0153.45.18.315.013.220.43.65
16、.69.017.212.719.03.65.78.815.413.921.8203.65.49.016.714.322.33.86.19.819.013.620.73.96.29.617.115.123.8253.95.99.818.615.524.54.06.610.721.314.722.74.26.710.519.116.426.2304.26.310.820.916.827.04.57.211.823.915.924.64.57.311.521.317.928.8354.56.912.023.418.529.84.97.913.226.717.427.24.98.112.823.819
17、.631.9404.97.613.326.420.433.05.48.714.729.719.130.05.48.914.326.721.735.1輕負荷區(qū)吊線 原始垂度標準吊 線 程 式7/2.2 7/2.67/3.0 懸掛電纜重量W(千米/克)W1.46W0.574W1.46W0.574W1.46W0.574 垂度(厘米) 桿距(米)氣溫(C0)253035404550552530354045505525303540455055-202.43.65.37.510.610.813.32.43.75.47.811.111.515.02.43.85.78.111.611.815.5-152.53
18、.85.68.011.411.414.12.53.95.78.311.912.215.92.54.05.98.512.412.516.4-102.64.05.98.512.112.114.92.74.16.18.812.712.916.92.74.26.29.113.313.317.5-52.74.26.29.012.912.815.92.84.36.59.413.713.718.02.84.46.69.714.314.118.702.94.56.69.614.013.616.93.04.66.910.114.814.619.33.04.77.110.515.515.120.053.14.77
19、.110.415.114.618.23.24.97.310.916.015.620.73.25.07.611.316.916.221.6103.35.07.611.216.515.619.53.45.27.911.817.516.822.43.45.38.112.218.517.423.3153.55.48.212.218.016.821.13.65.68.512.819.218.224.33.65.78.813.420.318.825.3203.75.88.913.320.018.222.93.86.09.314.021.219.726.43.96.29.614.722.520.527.62
20、54.06.39.714.721.919.724.94.16.610.115.523.521.428.84.26.710.416.225.022.330.2304.36.910.616.224.321.527.24.57.111.117.126.023.431.54.57.311.518.027.724.533.1354.77.511.818.027.023.529.84.97.812.319.128.925.734.55.08.112.820.130.527.036.2405.28.313.120.230.025.832.75.38.713.721.332.128.337.35.48.914
21、.322.534.129.739.8 三、敷設(shè)架空光纜及墻壁光纜1、光纜及掛鉤規(guī)格:應(yīng)符合下表要求。掛鉤程式選用表掛鉤程式光纜外徑(毫米)351318或掛2條光纜2512及以下2、光纜布放A、光纜驗收時應(yīng)注意檢查以下內(nèi)容: a)光纜盤外包裝檢查; b)光纜盤生產(chǎn)檢驗證明文件(或報告),并收管好; c)光纜盤生產(chǎn)編號、長度、記錄(原報告),并收管好; d)光纜使用段落、記錄(隨工填寫)。光纜布放應(yīng)通過滑輪牽引,牽引力應(yīng)不超過光纜允許張力的80,瞬間最大牽引力不得超過光纜允許張力的100,主要牽引力應(yīng)加在光纜的加強件(芯)上。布放過程中應(yīng)無扭轉(zhuǎn),擦傷,打小圈,浪涌,過度彎曲等現(xiàn)象發(fā)生,并禁止未經(jīng)訓
22、練的人員上崗和無聯(lián)絡(luò)工具的情況下作業(yè);掛鉤應(yīng)搭扣一致,托板齊全,均勻垂直吊掛,間距為50cm±3cm。B、預(yù)留處理重負荷區(qū)和超重負荷區(qū)架空光纜應(yīng)在每根桿上作預(yù)留,中、輕負荷區(qū)應(yīng)每間隔200m左右一處小預(yù)留;對角桿坡度變化桿(15桿距)、長桿(75100m)兩側(cè),增加小預(yù)留;每隔500米做68米大預(yù)留光纜;101200米長桿檔,兩側(cè)電桿上各預(yù)留光纜68米,200米以上長桿檔各預(yù)留12米;預(yù)留應(yīng)盤放整齊, 彎曲半徑不得小于光纜外徑的20倍。附下表:光纜預(yù)留長度表項 目自然彎曲增加長度人孔內(nèi)彎曲增加長度桿上小預(yù)留長度接頭重疊長度設(shè)備側(cè)預(yù)留長度架空預(yù)留(m)5/Km10.2 121012C、
23、光纜接續(xù)(管道和架空敷設(shè)方式)光纖接續(xù)采用熔接法,并應(yīng)用OTDR實時監(jiān)測。光纜接頭盒內(nèi)盤好后的光纖應(yīng)滿足工程和日后維護三次接續(xù)的需要,一般長度為1.5m。每個接頭損耗值應(yīng):測試波長為1310nm時0.08dB/個;測試波長為1550時0.06dB/個。D、架空、管道光纜接頭盒的安裝加強芯在盒內(nèi)應(yīng)固定牢固,并與盒內(nèi)金屬固件絕緣,盒內(nèi)光纜兩個端頭的加強芯及金屬護套不作電氣連通;終端盒內(nèi)的光纜和尾纖應(yīng)做好端別、纖序標志;接頭盒密封應(yīng)嚴實,安裝應(yīng)牢固、安全可靠。四、中繼段光纜傳輸損耗、色散要求本工程各中繼段光纜接頭損耗0.06dB,偏振模色散按附表要求。附表: 中繼段光纜傳輸損耗、色散要求表(一)名 稱單 位數(shù) 值中繼段長km工作速率Gb/s工作波長nm光連接器衰耗dB/兩端光纜衰耗系數(shù)DB/Km中繼段光纖衰耗dB接頭允許衰耗DB/個接頭個數(shù)個中繼段接頭衰耗dB光纜線路富余度dB中繼段線路衰耗dB光纖色散系數(shù)PS/nm.km中繼段總色散PS/nm單盤偏振模色散系數(shù)Ps/Km傳輸段偏振模色散Ps五、防護措施A、架空光纜的防護措施a)雷電防護:新設(shè)架空光纜吊線每隔1000米接地一次。接地體采用50×50×5mm型1.5米角鋼長,連接采用40×4m
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 產(chǎn)品合作加工協(xié)議合同范本
- 2025年度智能電網(wǎng)建設(shè)與運營合同范本
- 2025年鋼琴健盤項目投資可行性研究分析報告
- 學校采購合同范本
- 中介加盟合同范本
- 關(guān)于水暖維修合同范本
- 停車廠轉(zhuǎn)租合同范例
- 2025年度工礦產(chǎn)品綠色生產(chǎn)標準制定合同
- 2025年度酒水行業(yè)廣告代理合作協(xié)議范本
- 2025年度國際知識產(chǎn)權(quán)授權(quán)與使用合同范本
- 服裝廠安全生產(chǎn)培訓
- 城市隧道工程施工質(zhì)量驗收規(guī)范
- 2025年湖南高速鐵路職業(yè)技術(shù)學院高職單招高職單招英語2016-2024年參考題庫含答案解析
- 五 100以內(nèi)的筆算加、減法2.筆算減法 第1課時 筆算減法課件2024-2025人教版一年級數(shù)學下冊
- 2025年八省聯(lián)考陜西高考生物試卷真題答案詳解(精校打印)
- 2025脫貧攻堅工作計劃
- 借款人解除合同通知書(2024年版)
- 《血小板及其功能》課件
- 沐足店長合同范例
- 《既有軌道交通盾構(gòu)隧道結(jié)構(gòu)安全保護技術(shù)規(guī)程》
- 初中物理22-23人大附中初三物理寒假作業(yè)及答案
評論
0/150
提交評論