1、N2 SeriesAdjustable FrequencyA.C. Motor DriveTAIA NN2-220V0.422KW( 1.233.2KVA )0.7522KW( 1.736.6KVA )N2-440VOperations ManualTable of ContentsForeword1Precautions for Operation2Operational Environment6General Introduction7Specifications9Wiring Rules11Keypad Operations21Parameter List22Functional Des

2、cription30Failure Codes60Maintenance Section65Filters66Dimensions70Breaker Resisters & Reactors74Trouble Shooting78ForewordTo fully employ all functions of this Taian T-verter, and to ensure the safety for its users, pleasethrough this operations manual in. Should you have any further questions,

3、 please feelto contact your local distributor or regional representative.PLEASE AND UNDERSTAND THIS MANUAL BEFOREOPERATING THIS T-VERTERThe T-verter is a power electronic device.For safety reasons, pleasecarefully thoseparagraphs with “WARNING” or “CAUTION” symbols. They are important safety precaut

4、ions to be aware of while transporting, installation, operating or examining the T-verter. Please follow these precautions to ensure your safety.nel injury may be resulted by improper operation.The T-verter or mechanical system may be damaged by improper operation.1CAUTIONl Do not attempt to perform

5、 dielectric strength test to internal components of the T-verter. There are sensitive semiconductor-devices vulnerable to high voltage in the T-verter.l Do not connect the output terminals: T1 (U), T2 (V), and T3 (W) to AC power inputl The CMOS IC on the primary PCB of the T-verter is vulnerable to

6、static electrical charges. Do not contact the primary PCB of the T-verter.WARNINGl Do not touch the PCB or components on the PCB right after turning off the power before the charging indicator went off.l Do not attempt to wire circuitry while power is on. Do not attempt to examine the components and

7、 signals on the PCB while T-verter operating.l Do not attempt to disassemble or modify internal circuitry, wiring, or components of the T-verter.l The grounding terminal of the T-verter must be grounded properly (200V class:Ground to 100 or less, 400V class: Ground to 10 or less).l This is a product

8、 of the restricted sales distribution class according to EN61800-3.In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.CAUTIONWARNINGPrecautions for operationExamination before installationEvery T-verter has been fully

9、tested and examined before shipment. Please carry out the following examination procedures after unpacking your T-verter.zCheck to see if the mthat you ordered.number of the T-verter matches the mnumber of the T-verterzCheck to see whether any damage occurred to the T-verter during shipment. Do not

10、connect the T-verter to the power supply if there is any sign of damage.Before turning ON power2CAUTIONl Do not attempt to transport the T-verter by the front of the cover. Securely hold the T-verter by the heat-sink mounting chassis to prevent the T-verter from falling, this may causenel injury or

11、damage to the T-verter itself.l Install the T-verter onto a firm metal base plate or another non-flammable type material. Do not install the T-verter onto or nearby any flammable material.l An additional cooling fan may need to be installed if several T-verters are installed into one control panel.

12、The inside temperature inside an en d panel should be below 40 degrees to avoid overheating.l Turn off the power supply before proceeding to remove or perform any work on any panel. Carry out installation procedures according to instructions given in order to avoid a situation resulting in an operat

13、ional malfunction.l This product is not provided with over speed.l Only intended for use in a pollution degree 2 macro environment or equivalentWARNINGSpecial care must be taken while wiring the primary circuitry terminals. The (L1) (L2) and (L3) terminals must be connected to the input power source

14、 and must not be mistakenly connected to (T1) (T2) or (T3) output terminals. This may damage the T-verter when the power is turned on.CAUTIONChoose the appropriate power source with correct voltage settings for the input voltage specification of the T-verter.When power is appliedUnder Operation3WARN

15、INGl Do not remove the front cover of the T-verter when the power is ON to avoid nel injury caused by electrical shock.l When the automatic restart function is enabled, the motor and machinery will be restarted automatically.WARNINGl Do not use a separate device to switch ON or OFF motor during oper

16、ation.Otherwise, the T-verter may experience an over-current breakdown.l When momentary power loss is longer than 2 seconds (the large of horse power, the longer of time), the inverter does not have enough storage power to control the circuit; Therefore, when power is regenerated, the operation of t

17、he inverter is based on the setup of Fn_10/16 and the condition of external switch, this is considered to berestartin the following paragraphs.l When the momentary power loss is short, the inverter still has enough storage power to control the circuit; therefore, when power is regenerated, the inver

18、ter will automatically start operation again depends on the setup of Fn_31/32.l When restart the inverter, the operation of the inverter is based on the setup of Fn_10 and the condition of external switch (FWD/REV button). Attention: the restart operation is irrelevant with Fn_31/32/34/35.1. When Fn

19、_10=0, the inverter will not start after restart.2. When Fn_10=1 and the external switch (FWD/REV button) is OFF, the inverter will not start after restart.3. When Fn_10=1, the external switch (FWD/REV button) is ON, and Fn16= 0, the inverter will start automatically after restart. Attention: Base o

20、n safety reason, please turn off the external switch (FWD/REV button) after power loss to avoid possible damage to the machine and the human body after sudden regeneration of power.WARNINGDo not attempt to install or remove input or out put connectors of T-verter when the power supply is turned on.

21、Otherwise, the T-verter may be damaged due to the surge peak caused by the insertion or removal.When perforan examination or maintenanceOthers4WARNINGNever modify the product.Failure to observe this warning can result in an electrical shock oral injury and will invalidate the guarantee.CAUTIONThe en

22、vironment temperature should be within 10OC +40OC and humidity under 95% RH without condensing. Besides, the T-verter should befrom water dripor metal dust.CAUTIONDo not proceed with disassemble or examination procedure before ensuring that the power is off and the Power LED extinguished.CAUTIONl Do

23、 not touch the heat-sink base during operation.l The T-verter can be easily operated from a low-speed to high-speed range. Please reconfirm the operating range of motor and the machinery you are controlling.l Do not examining the signals on the PCB of the T-verter when it is under operation.l All T-

24、verters are properly adjusted and set before delivery.Taking Precautions:oilAvoid any direct sunlightKeep away from corrosive gas or liquidKeep away from oil grease and gasAvoid metal dust and dusty environmentsKeep away from saltyenvironmentsAvoid where environmental temperatures are too highAvoid

25、massive vibrationAvoid excessive direct heatKeep away from high electrical-magnetic waves or ultra-high waves.Keep away from radioactive matterKeep away from flammable material5Keep away from rain or where dripwater may get into the T-verterOperational EnvironmentThe installation site of the T-verte

26、r is very important. It relates directly to the functionality and the life span of your T-verter. Please carefully choose the installation site to meet the following requirements:zzzzzzzzzzMount the unit verticallyEnvironment temperature: -10OC +40OC(with cover removed: -10OC +50OC)Avoid placing Avo

27、id water dripto any heating equipment or humid environmentAvoid direct sunlightAvoid oil or salty corrosive gasAvoid contacting corrosive liquid or gasPrevent foreign dusts, flocks, or metal scraps from entering interior Avoid electric-magnetic interference (soldering or power machinery)Avoid vibrat

28、ion, if vibration cannot be avoided, an installed to reduce vibration.-rattle mounting device should bezIf the T-verter is installed in an end control panel, please add additional cooling using anexternal fan. This will allow additional airflow and cooling.Placement of external fans should be direct

29、ly over the top of the T-verter.For proper Installation of the T-verter you must place the front side of the T-verter facing front and the top of the T-verter in the up direction for better heat dissipation.Installation must be compliant to the following requirements.zzzT-verterVentilation-10OC +40O

30、C & Installation DirectionFront & Side Views6GeneralT-verter N2 series is a high performance general-purpose inverter that incorporates a high efficiencyPulse Width Modulated () design and advancedtechnology. The outputlyapproximates a sinusoidal current waveform to allow variable speed cont

31、rol of any conventionalsquirrel cage induction motor.ReceivingThis unit has been put through demanding tests at the factory prior to shipment.Before unpacking please check the following:1.Identify the description of the product found on the label with your purchase order.2.Inspect for transport dama

32、ge (serious damage of carton may lead to damage of the unit)Please check the followings after unpacking:a.Check if the specifications (current & voltage) on the front cover match yourapplication requirement.b.Check all the electrical connections and screws.c.Verify that there is no visible damag

33、e to any of the components.If any part of the T-verter or the box it came in is damaged, please notify the carrier and yourdistributor immediately.7General Introduction:LocationPicking the proper installation location for the T-verter is imperative in order to achieve the um specified performance &a

34、mp; operation from the Drive. The T-verter should always beinstalled in areas where the following conditions exist.*Good ambient operating temperature:-10 to 40 C (14 to 104 F), -10 to 50 C (14 to 122 F) with cover removed*IP Rating: IP 20 for all ms. If the T-verter is placed in another enclosure,

35、please provideaddition cooling using an external fan. Protected from rain & moisture.Shielded from direct sunshine.from metallic particles and corrosive gas. from excessive vibration. (Below 0.5G)*PositioningFor effective ventilation and maintenance purposes, sufficient clearance (as shown in fi

36、gure 2.1) around the T-verter is necessary. The T-verter must be installed with heat sink ribs oriented vertically.VO LT AM PzAllow 12cm clearance on bothsides of the enclosureFUN 0 100 zBe sure to allow the air to move ly through the heat sinkarea.8Installation:N2Series-2Input Voltage 2 : 200V Clas

37、s 4 : 400V Class01Capacity P5 : 0.5Hp30 : 30HpHSpecificationM : Standard type H : Advanced type3Phase of input power Blank : 1/3 phase3 : 3 phaseN4Enclosure Blank : IP20N4 : IP65(NEMA4)Note *1 (IP65) NEMA4 enclosure type only available for 0.5 10HP & below9N2- -*1401402403405408410415420430Horse

38、 Power12357.510152030Rated Motor KW0.751.52.23.75.57.5111522Rated Current (A)2.33.85.28.81317.5253248Output (KVA)1.72.94.06.79.913.319.124.436.6Input Voltage Max.( 3 Phase 380 480 Volts +- 10%) (50/60Hz +- 5%)Output Voltage Max.3 Phase 380 480 Volts (proportional to input voltage)IP20 Weight (Kg)2.4

39、2.53.84.07.07.312.312.513.5Power LossRide Through (s)1122222223 Phase 380 480 VoltsN2- *12P5201202203205208210215220230Horse Power1/212357.510152030Rated Motor KW0.40.751.52.23.75.57.5111522Rated Current (A)3.14.57.510.517.52635496487Output (KVA)1.21.72.94.06.79.913.318.724.433.2Input Voltage Max.(1

40、 / 3 Phase) (200240 Volts +-10%) (50/60Hz +-5%) (5 h.p. & above 3 Phase Only)Output Voltage Max.3 Phase 200 240 (proportional to input voltage)IP20 Weight (Kg)1.41.42.54.04.06.87.112.312.513.8Power LossRide Through (s)11222222221/ 3 Phase 200-240 VoltsMode No. IdentificationBasic Specification:l

41、 N2-205 and above capacity are not CE complied10Control CharacteristicsCarrier frequency1 - 12 KFrequency Control Range0.1 400 HzFrequency AccuracyDigital: 0.01% (-10 40 °C); Analog: 0.4% (25+-10 °C)Frequency Resolution0.01 Hz with computer or PLC control, 0.1 Hz with keypad control when f

42、req. above 100 HzFrequency Setting Signal(0-5VDC) (0-10VDC) (4-20mA) (0-20mA)Accel / Decel Time0.1-3600 SEC with (2) S-curvesBraking TorqueAbout 20% (built-in Braking transistor)V/F Pattern18 patterns, one curve programmableFunctionInstantaneous Over CurrentApprox. 200% rated currentOverloadT-verter

43、: 150% / 1 minuteMotor OverloadElectronic thermal overload relayOver voltage200V series: (DC bus exceeds 427V) 400v series: (DC bus exceeds 854V)Under voltage200V series: (DC bus drops < 200V)400v series: (DC bus voltage drops < 400V)Momentary Power Loss02 seconds: The T-verter can be restarte

44、d using the speed search featureHeat Sink Fin OverheatProtected by thermisterGround FaultElectronic circuitOperation ConditionsInput SignalOperation signalsForward/Reverse operation, by keypad or hardwire contact, multiple individual dsResetReleasedwhile the protective function is operatingMultifunc

45、tion InputRefer to function illustration in Fn_56Output SignalMultifunction OutputRefer to function illustration in Fn_61Fault output250VAC 1A, 30VDC 1A or lessBuilt-in FunctionFrequency reference bias/gain; up/lower limit; manual torque boost; frequency meter calibrating gain; auto restart attempt;

46、 skip frequency; S-curve ACCEL/DECEL; Carrier frequency adjust.(1-12KHz)Communication link functionDigital operator monitorFrequencyd, output frequency, speed, output current, output voltage, P-N bus voltage, rotating directionAnalog Output MonitorAnalog output (0-10V), possible to select output fre

47、quency & setting freq. & output voltage & P-N bus voltageEnviron mentalLocationIndoor (protected from corrosive gas and dust)Ambient Temperature-10 degrees 40 degrees © 50 degrees with cover removedHumidity0-95%(non condensing)Vibration0.5GEnclosureIP20 / IP65 (NEMA4)EMCEN50081-1, E

48、N50082-2 (with optional filter)LVDEN50178ULUL 508CFunctional Specification:1.A.Notice for wiringScrewdriver torque: Connect cables with a screwdriver or other tools and follow the torque listed below.B.Power wiresPower wires are wires connected to L1, L2, L3, T1, T2, T3, P and R. Choose wires in acc

49、ordance with the following criteria:(1) Use wires with copper cores only. Decide diameters of wires based on working conditions at 105oC.(2) For nominal voltage of wires, the minimum voltage of 240VAC type is 300V, and 480VACtype is 600V.C.Control wireControl wire is connected to TM2 control termina

50、l. Choose the wire in accordance with the following criteria:(1) Use wires with copper cores only. Decide the diameter of the wire based on working conditions at 105.(2) For nominal voltage of wires, the minimum voltage of 240VAC type is 300V, and 480VAC type is 600V.(3) To avoid noise interference,

51、 do not route the control wire in the same conduit with powerwires and motor wires.D.Nominal electrical specifications of the terminal base: The following are nominal values of TM1:11Securing torqueHorsepowerPower source Max.Nominal torque for TM1 terminal0.5/1/2/3200 240V1.33 lbs.-ft16 lbs.-in1/238

52、0 480V5/7.5/10200 240V1.15 lbs.-ft13.8 lbs.-in3/5/7.5/10380 480V15/20/25/30200 240V1.83 lbs.-ft22 lbs.-in15/20/25/30380 480VWiring Rules:Note: Nominal values of input and output signals (TM2) follow the specifications of class 2wiring.2.Fuse typesTo protect the inverter most effectively, use fuses w

53、ith current-restraint function.12HorsepowerPower source Max.Rated fuse specifications2200 240V15A, 600VAC, 100KA, I.R.320A, 600VAC, 100KA, I.R.530A, 600VAC, 100KA, I.R.7.5/1060A, 600VAC, 100KA, I.R.15/20100A, 600VAC, 100KA, I.R.25/30150A, 600VAC, 100KA, I.R.1380 480V5A, 600VAC, 100KA, I.R.210A, 600V

54、AC, 100KA, I.R.315A, 600VAC, 100KA, I.R.520A, 600VAC, 100KA, I.R.7.5/1040A, 600VAC, 100KA, I.R.15/2070A, 600VAC, 100KA, I.R.25/30100A, 600VAC, 100KA, I.R.HorsepowerPower source Max.VoltsAmps0.5/1/2/3200 240V300201/2380 480V5/7.5/10200 240V600403/5/7.5/10380 480V15/20200 240V6006015/20/25/30380 480V2

55、5/30200 240V6001003.Use the circuit properly, and the carrying current does not exceed 5000 Arms.Theum output voltage is 240V for 200 240V ms when carryingcurrent is below 5000 Arms.Taian cannot guarantee safety for over-speed or similar situations. Do not connect the inverter to a controller or similar devices with cur

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論