網(wǎng)絡(luò)設(shè)備-工業(yè)交換機(jī)四方csc_第1頁(yè)
網(wǎng)絡(luò)設(shè)備-工業(yè)交換機(jī)四方csc_第2頁(yè)
網(wǎng)絡(luò)設(shè)備-工業(yè)交換機(jī)四方csc_第3頁(yè)
網(wǎng)絡(luò)設(shè)備-工業(yè)交換機(jī)四方csc_第4頁(yè)
網(wǎng)絡(luò)設(shè)備-工業(yè)交換機(jī)四方csc_第5頁(yè)
已閱讀5頁(yè),還剩66頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

CSC-187ZIndustrialEthernetThankyouforusingproductsofBEIJINGSIFANGAUTOMATIONCO..Forsafety,properandefficientusingofthisdevice.PleasebesuretonotethefollowingimportanttipsThisspecificationonlyapplytoCSC-187ZIndustrialEthernetswitchPleasereadthisspecificationcarefullyandfollowthespecificationfortheadjusting,testingandoperating,ifthereisaattached,pleaserefertoprevailwiththeinandtouchchipsandcomponentsonelectricbroadPleaseusequalifiedtestequipmentsfortestingandinspectingproductsIfproductsoperateabnormalorneedrepairservice,pleasecontactourservicehotlineintimeDevice Technical Environment Electricalinsulating Mechanical Electromagnetic Themaintechnical Production Basic Application Devicehardware System Hardware Backoutgoing Frontoutgoing PowerandAlarm Device Open-package Inspectionbeforepower Self- RJ-45port Opticalinterface DeviceWEB Basic Port Configuration Time switch Macaddressfico. baudrate(flooding EG.Forconfiguring delete QOS/Priority QOSport priority Redundancy Ring loopback trouble Port port CLI common port configuring configuringloopback configuring DeviceCSC-187Z,developedbyBEIJINGSIFANGAUTOMATION speciallydesignedforinligentsubstationwithhighreliability,availabilityandsecurity.Itcanbeinstalledinasmallinligentsubstationroom,switchcabinetandprefabricatestoragetoprovidereliableandsafesolutionforinligentsubstationCSC-187Zadoptsadvanceddesignconcept,fullyconsideredtheindustrialenvironmentinavarietyofharshconditionsandinterferencefactors,usingaunifiedhardwareplatformandsoftwareplatformtosupportvarioustypesofcommunicationinterfaces,modularinterfacetofacilitateoperationandmaintenance.Theuseofadvancedcoolingtechnologyandlowpowertechnologytoensurereliabledeviceoperatesat-40℃~+85℃environment,ahighlevelofEMCdesign,ensurethatthedevicecanadapttoavarietyofharshindustrialenvironment.Designedspecificallyforthepowerindustry,complywithIEC61850standard,applytothepowerindustryscenarios.Excellentanti-electromagneticinterferencecapabilityandtemperatureflexibility,canlong-termstableoperationinharshprovideindustrialwidevoltagepowersupplyredundantdualpowersupply,supportAC85~265V,DC110~330V。Switchforwarddelayislessthan3μs,ensuringdatafastSupportfront/rearpanelcableentryforelectricity6.1~28canbeconfiguredtoa10/100BaseTXor10/100BaseFX(ST//SFPoptional),ofwhich25~28canbeconfiguredasGigabitopticalinterfacesorGigabiectricalinterfacestoprovideuserswithaflexiblenetworking.SupportQOSfeature,provideflexibleapplicationsecuritytomeettheelectricityindustrylowdelay,andhighreliabilityrequirement.ProvideTrunkfunction,IGMPSnoo、IGMPV1/V2/V3,supportGMRPSupportSTP/RSTP,MSTP,privateringSupportport-basedvlanandtagvlanbaseonProvideportsecuritycontrol,broadcaststormcontrolandportmirroringfunctionProvideSNMPmanagement,Web-basedmanagementandCLIcommandlineIP40ingressprotection,stronganti-interferencedesign,highEnvironmentoperatingtemperature:-relativehumilityoperating/noAtmosphereingressElectricalinsulatinginsulationdielectricpowersupplyandwarmingvoltagetoground2KV,thecopperportvoltagetoground0.5KV thecopperportvoltagetoground1KVMechanicalVibrationdurabilitytomeetGB/T15153.2standardadegmclassforGB/TShockmeetGB/T15153.2standardCmlevel3)collisionmeetGB/T15153.2standardadeElectromagneticElectrostaticdischargeimmunitymeetGB/T17626.2-2006gradeRFEMSmeetGB/T17626.3-2006gradegrade4Surge(shock)immunitymeetsGB/T17626.5-2008gradeRFImmunitytoconducteddisturbances,inducedtomeetGB/T17626.6-2008grade4PowerfrequencymagneticfieldimmunitymeetGB/T17626.8-2006grade5DampedoscillatorymagneticfieldimmunitymeetGB/T17626.10-1998grade4PulsemagneticfieldimmunitymeetGB/T17626.10-1998gradeOscillatorywavesimmunitymeetGB/T17626.12-1998gradepowerinputportvoltagedips,shortinterruptionsandvoltagevariationsimmunityGB/T17626.29-2006requirementsSupportserrorsourceaddressfilteringonthesourceaddressbelongstoabroadcastaddressormulticastaddress.supportCRCerrorcheckcrash,restart,lossoffunctionorpacketloss.ThemaintechnicalIEEEIEEE802.3IEEE802.3u100BaseTXIEEE802.3abIEEE802.3xflowIEEE802.1dSTP/IEEE802.1wIEEE802.1qVLANIEEE802.1pSwitMacaddress4096Multicast256multicastbroadcast1)port-based2)Supportforbroadcast,unknownunicast,multicast,suchasdifferenttypesStormFlowDuplexflowcontrol.halfduplexflow1000MConfigure4copperportsandSFPfiberFastOptionallyconfiguredas10/100Baseectricalor10/100BaseFXfiberports(ST/SC/SFPoptional),powerporttransmissiondistanceislessthanorequalto100meters,theopticaltransmissiondistance2Km~100KmSystemRUN、ModuleWARMINGEthernetphysicalport:RJ-45 port:10Base-T/100Base-TX auto-negotiationfunctiondistance:<100Radiantpower:-20~-14dBm(MBmultimodeLCMBmultimodeSC/ST)-23.5~-14dBm(MBmultimodeLCMBmultimode-9.5~0dBm(GigabitmultimodemultimodeSC/ST)≤-31dBm(MBmultimodeLCMBmultimode≤-21dBm(GigabitmultimodeCompulsoryreceivingsensitivity:-25dBm(MBmultimodeLC)-12.5dBm(Gigabitmultimode-13.5dBm(Gigabitmultimodewavelength:1310nm(MBmultimodeLC),(GigabitLC,0.5K(GiabitPower-Storage-Relative5%~95%(NocondensationIndustrystandard19-inch1UlProtectionThermalFullyenclosed,fanlessdesign,airconvection,chassiscoolingProductcertificationelectric:IEC61850-3,IEEE1613industry:IEC61000-6-2,IEC61800-ProductionBasicstore-and-redundantdualpowerconfigurationdevice (memory,flash,eepom,rtc,mac/phyetc.)loopbacktest:forfactoryproductionApplicationindicationCSC-187ZindustryEthernetswitchdisplayportstatusbyfrontpanelLEDs,includetransmissionra inkstatus,powerandsystemstatus.PWRlight:green,systemispoweredsteadyrunled:green,systemisoperatingnormallyalmled:red,erroroccursduringprogramoperationbakled:offm/sled:speedled:green,portisoperatingat100/1000 led: green,activity,portissending/receivingdataPowerfailureCSC-187ZEthernetswitchhaveagroupofnormallyopenandnormallyclosedpowerfailurealarmcontactor,shownbelowRelayterminalsPhoenix3Signal123layer2switode:store-and-switchdelay:lessthanMACaddressmacaddresstablemacaddresslearningrate(>1000prioritynumber:framebufferVLANdivideanetworkintomultiplelogicalnetworks.DatapacketscannotbetransmittedbetweendifferentVLANstocontrolthebroadcastandsegmenttraffic,VLANcanimprovenetworkperformance,securityandIEEE802.1QAssigningVLANbaseonphysicalports,SupportforVLANIDsinthe1to4096rangeVLANQualityofservice,isanetworksecurityprotocol,inordertosolvenetworkissuessuchastrafficlatencyandcongestion.whennetworkisoverloadedorblocked,QOScaninsurecriticalapplicationnottobedelayedorabandoned,atthesametime,keenetworkoperationinaefficientway.IEEE802.1pisthemostwidelyusedpriorityprojectinlanenvironment802.1psupport4query、8prioritysupportstrictpriorityandrelativeportPortmirroringfunctioncansendthecopyofaportorseveralportsdatatooneswitchportforrealtimemonitoringflowCSC-187ZindustryEthernetswitchvianetworkmanagementcansetsendingandreceivingrateofallportsFastportisconfiguredrategranularityladder:128K、256K、512K、1M、2M、10M、50M100M.Gigabitportisconfiguredrategranularityladder:100M、500M、staticManualaddingstaticmulticastandmulticastparingtodynamicmulticast,advantagesofstaticmulticastaresimple,reliableandlow-delay,anddonotrequireprotocoltoparticipate.youcanconfigurestaticmulticastforwardingtabletoachievemulticastdataforwarding.usercanmanuallyconfiguremulticastgroup.staticgroupcommunicationandIGMPcannotberunningsimultaneouslyIGMPIsinternetgroupmulticastprotocol,CSC-187ZprovideIGMPmonitorandquery,packetscanbesenttoseveralstationstoproverloadprotection.thussolvingtheissuethatbroadcastpacketsoccupybandwidthConfiguringonause“activemode”tosupport“router-less”BychangingRSTPtopology,youcanrestoredatasupportupto256IGMPbroadcaststormWhentoomanybroadcastpacketsaresenttothenetwork,becausethesepacketstakeupmostofthetransmissioncapacitytoleadanetworktimeoutcircumstancecallednetworkstorm.CSC-187Zsupportsbroadcastmulticastpackets,andbroadcaststormcontrol,droppacketsthatexceedsauser-configuredtimelimitunknown-unicastmulticastbroadcaststormdroppacketsthatexceedsauser-configuredtimeredundancyprovideSpanningtreeprotocolandrapidspanningtreeprotocolTRN-ringloopprotocolprovideredundancyprotectioninEthernetnetwork,RSTPcanachieveallfunctionsofSTP’s,differentbetweenRSTPandSTPisdecreasedelay-timefromportblocktoportforward.assoonaspossibletorestorenetworkconnectivitySupportSTP/RSTP/MSTP,RSTPprotocol,restoring-timelessthanSupportCLI/WEB/SNMPconfigurationparameters/showSupportTRN-RING,protocolrestoreingtimelessthan30ms,support80Thisfeatureistherealizationofreal-timetransmissionschedulingdevicealarm.Alarmfunctionsincludeportalarm,ringalarm,etc.,avarietyofnetworkmanagementsoftwarecanenablethealarmfunction,thealarminformationdisplayonnetworkmanagementGUI..deviceswarming(loopbacknode,deviceinterface,poweralarm,undeterminedalarm)SupportCLI/WEB/SNMPconfigurationparameters/showSNMPSNMP(SimpleNetworkManagementProtocol)isthenetworkmanagementiswidelyusedinmanytypesofnetworkequipments,softwaresandsystems.SNMPhavemangadvantagessuchasitiseasytoimplement,isaopenfreeproductandcanbeusedtocontrolavarietyofdevices.soitiswidelyusedinthenetworkingindustry.GMRPismulticastregistrationprotocolbaseonGARP.isusedtooperateswitulticastregistrationinformation.allswitchessupportingGMRPprotocolcanreceivemulticastregistrationinformationfromotherswitches.anddynamicallyupdatinglocalmulticastregistrationinformation.butalsosendinglocalmulticastregistrationinformationtootherswitches.thisinformationexchangemechanisminsurethatswitchessupportingGMRPinsamenetworkmaintained multicastinformationconsistently.whenastationwanttojoinmulticastgroup,itwillsendGMRPjoinmessage.switchportreceivedmessageanaddGMRPjoinmessageintomulticastgroup.andbroadcastGMRPmessagefromtheportwheremessagesisreceived.multicastsourceinnetworkdiscoverexistentofmulticastmember.whenmulticastsourcesendmulticastmessagetomultigroup.switchonlysendmulticast group.thereby.layer2multicastinvlanisimplementedLLDPisanewprotocoldefinedby802.1ab,Neighbordeviceadvertiseitsstatusnotificationtootherdevices,meanwhile,eachportofalldevicesstoreowninformation.ifneeded,theycansendupdateinformationdirect-connectdevices,NeighbordevicecanstorageinformationinSNMPMIBsNetworkmanagementsystemcanquerynetworkprotocolforcurrentlayer-2linkstatus.ManagementBaseonconsole,deviceconfiguration/monitor/debugnet-baseddeviceconfiguration/monitor/debugWEB-baseddeviceconfiguration/monitor/debugCLIsupportsunifiedconfigurationmanagementmonitormonitoringSupportshow/clearcurrentportpacketSupportconsole/net/webshowSupportrunningstatusinformationtologSupportlogfunction,recorddeviceoperatingSupportlogSupportlogquery/clear/uploadSupportCLI/WEBconfigurationparameters/showsecuritySupportmulti-user,useradd/delete,modifySupportsettinguserlevel,eachlevelleadtodifferentSupportenable/unableport,unableaporttoblockdatainthisSupportmacbasedsecurityencryptiononaswitchinterfacetoauthorizeaspecificdeviceandmacaddressinformationtothroughthisNeedpasswordformanagementDevicehardwareCSC-187Zindustrialswitchingsystemstructureshowsinbelow,whichuseshigh-performanceindustrialEthernetswitchsingle-chipsolution,dataexchangeonallportsarebasedoninterexchange,soastoensurethatallportdatatransmissiondelaybasicallythesame,whileusingimportedpowerandintegratedchassiscoolingdesign,thisdesignensuresthatthedevicetemperaturecharacteristicsandEMCperformanceareconsistent.IntermsofitsimmunitytoIEC'sEMC/EMIhigheststandards,canbeadaptedtoavarietyofharshindustrialenvironmentcondition.Atathermaldesign,CSC-187Zusesadvancedcoolingtechnologyandlowpowertechnologytoensuretheequipmentwithallopticalportsisnormallyrunning(-40~+85℃).CSC-187ZindustrialswitchingsystemstructureCSC-187Zadoptsmodularinterfacedesign,toensuretheumflexibilityofconfiguration,insuretoapplytoadifferentsiterequirements.Itprovides28fullyconfigurableports,4Gbitportscanbeconfiguredas;integratedSNMPnetworkmanagementprotocol,IEC61850,Modbusandotherindustrialprotocols,supportsSTP,RSTP,MSTPandotherinternationalstandardsandprivateRINGringprotocolagreementswithindependentRINGproprietaryinlectualpropertyagreement,notonlyreducestherecoverytimeof"openloop",improvethetimeliness,butalsosupportsstar,ring,treeandothertopologies.HardwareCSC-187ZindustryEthernetswitchuses1Ustandardchassis,embeddeddevicedesign,front,rearcableentryoptionBackoutgoingPicture5-1Picture5-2Picture5-Picture5-FrontoutgoingCSC-187ZEthernetswitchsupportcablefrontentry,rearoutlet,whenusingfrontcableentry,switchPOW,RUN,ALARMledshowinfrontpanelBecaution:whenchoosingfrontcableentry,umconfigurationfastportnumberare22Picture5-PowerandAlarmCSC-187ZindustryEthernetswitchalarmterminalusePhoenixthreecoreterminal.powerterminalemployPhoenixsi Picture5-Power1PowerAC2PowerAC3PowerAC4PowerAC5not6GAlarmPhoenix31Normally2Relay3NormallyDeviceOpen-packageEquipmentintransport,storage,installationprocessmustbehandlewithcare.beforeinstall,devicerequirevisualinspectiontoensurethatnodamageexistsondeviceCSC-187ZindustryEthernetswitchcanmountonany19-inchracks.beforeinstallation.ensureaproperworkenvironment.includepowersupply.space,locationandotherdevicesimplement.pleasecheckfollowinginstallationrequirementsCSC-187Zproductmounton19-inchWhetherornothaveEnoughspaceforinstallationinCheckwhetherornotinstallrequiredwiringandpowerrequirementAvoiddirectsunlight.awayfromheatsourceandareaswithstrongelectromagneticinterferenceCheckthedevicechassisCheckwhetherthedeviceisproperlyCheckpowerwiringinstallingCheckthepowerinputvoltagemeetsthejobAfterpoweron,powerLEDisnormallyWhendevicepoweron.allportsLEDareonfor3seconds,thenLEDsturnoffLEDisoffRJ-45portUsingcabletoconnectdeviceEthernetportwithextradevice.portLEDsshouldbenormallyon.ifportLEDisoffthatmeanslinkhasnotsetup.afterconfiguringmanagementVLAN.usercaneachotherwithoutpacketslossonupport.inprocess.portLEDsshouldbeblinkingwhenpacketsaresendingorreceiving.whendevicecopperportsdisconnectoroperateabnormal.portLEDsshouldbeoffUsingfibertoconnectdevicefiberportandextradevicefiberport.notethedirectionoffiberoptictransceiver.onlyoneendcrossconnecttotheotherend.portlinkisup.sameascopperport.whenfiberopticportlinkestablish.portLEDshouldbenormallyon.meanwhile.usingprocesstocheckportconnectivityDeviceWEBCSC-187ZindustryEthernetswitchsupportWEBmanagement.byusingWEBmanagement,youcanviewswitchrunningstatus,basicinformationaswellasconfigureandupdateswitchonlineCSC-187ZindustryEthernetswitchprovideswebmanagement.thisWEBstructurebaseonJAVAenvironment.socomputerneedtoinstallJAVA(hasrecordedtoattacheddisk).switchdefaultconfigurationasfollowsDefaultDefaultDefaultDefaultsimple-Bydefault,followthesestepstomanuallyconfigureIPandloginUsecabletoconnectswitchwithcomputerEthernetpowerManuallyConfigurecomputerIPaddresstoOpenbrowser.enterswitchIPaddressinaddressbar.pressenterjum tothefollowingwebsiteEnterusernameandpassword,thenpressOKtoaccesstoswitchmanagementGUILeftsideisthemanagementtree pETC..presseachcategorytothenext BasicHit“basicconfiguration”innavbartoentertobasicconfigurationGUIshownasfigure4-3Hit”system”toentersystemconfigurationGUIshownasfigure4-4,thisGUIusesfordisplayingsystemstatus,configuringdevicename,location,andcontactETC.Name:thisbardisplaythemanagementnamedistrictedtomanagementLocation:displaydevicephysicalContact:displaythedescriptionofinformationofmanagementnodePower:displaytwodualpowersupplyrunningTemperature;settingdeviceoperatingtemperaturealarmlimits.andCurrentoperatingtemperatureHit”network”toenternetworkconfigurationGUIshownasfigure4-5ThisGUIusesformodifyingIPaddress,netmask,gateway.aftermodification,press“setting”,thenrebootswithtomakeSystemname:thisbardisplaydevicesystemIPaddress:configuresystemIPaddress,defaultisNetmask:configureanddisplaycurrentsystemnetmask,defaultisGateway:configureanddisplaycurrentsystemgatewayaddress,defaultaddressisMACaddress:displaydevicephysicalMACVLAN:displaysystemmanagementVLAN,defaultnumberisHit“software”toentersoftwareGUIshownasfigure4-6.thisGUIdisplayswitchsoftwareversionandupdateswitchbyTFTPSoftwareversion:displaycurrentsoftwareURLaddressbar,thenpresstftpupgradeNOTE:afterupgrading,youmustrebootPortHit“portconfiguration”toenterportconfigurationGUIshownfigure4-7.thisGUIusesforconfiguringportstatusandportPort,portdescription:representswitchlogicalportEnableport:configureaspecificportenabledorAuto-negotiation:usingforautomaticallynegotiatingportstatusenabledordisabledManualsetting:usingforconfiguringandviewingcurrentspeed/duplexmodestatus.configurerespectively:10Mbit/sHDX,10Mbit/sFDX,representhalf-duplex,FDXrepresentfull-duplex.connectedportsmusthavesameportconfiguration,otherwise,systemareunstableandabnormalforlong-termrunningLink/currentconfiguration:displayportlinkHit”reboot”toenterrebootconfigurationGUIshownas4-8.thisGUImainlyusesforoperatingswitchtocoldreboot,warmreboot,clearMACARPtableandportColdbooting:physicallycutdevicepowersupply,rebootWarmbooting:inswitchoperatingstatus.rebootClearMACaddresstable:deletestaticaddressinMACClearARPtable:deleteARPResetportcounter:resetportcounternumbertoConfigurationHit“configurationmanagement”toenterconfigurationmanagementGUIshownasfigure4-9.thisGUIusesforrestorethefactorysettingandsavedevice,allconfigurationsonswitchrestoretofactorydefaultstatusSaveconfiguration:saveyourentriesandchangesintheconfiguration“Hit“security”→“password”toenterpasswordconfigurationGUIshownasfigure4-10.thisGUIusesformodifyingpasswordThisGUIusesformodifyingdevicepassword,respectivelyread-onlypassword(user)andwrite/readpassword(admin),enterandverifynewpasswordthenpress“setting”.andthenpress”saveconfiguration”in“basicsetting”tocompletepasswordchangeTimeHit“time”→“SNTP”toenterSNTPconfigurationGUIshownasfigure4-11,thisGUIusesforSNTPconfiguration4-11SNTPConfigureSNTPauthoritativeasEnableSNTPauthoritativeAfterbooting,switchcanenableSNTPservermodeandclientmodeatsametimeSwitchasatimesourcesynchronizetimeforotherdevicesAnexampleshowshowtoconfigureSNTPservicecanbeoneorseveraladdresses,Sendinginterval:1toDisabledservice:disableSNTPasatimesourcetoprovidesynchronizationfunctiontootherdevicesSynchronizeswitchbyauthoritativetimesourceExampleshowshowtoconfigureSNTPclientIPaddress:sourceIPaddressredundantipaddressrequestinterval:Requesttimeinterval,rangefrom1to3600ReceiveSNTPbroadcast.UTC:CoordinateduniversalPress“switch”toenterswitchconfigurationGUI,thisGUIincludeglobal,macaddressfico.r,baudratelimit,multicast,VLAN,showninfigure4-14ConfiguringswitacagingMacaddress:displayswitchvirtualmacAgingtime:MACagingtime,allportsinswitchhaveautomaticallylearnedaddressfunction,agingtimeisaparametertoeffectswitchlearningprocess.countingtimefromamacaddresswhenmacaddressjointomactable.ifallportsdon’treceivesourceaddressthatisnotfrommacdynamicforwardingaddresstable.andstaticmacaddresstableisnoteffectedbyagingtime Addresslearning:macaddresslearning,macaddresslearningdescribeLearningmacaddressservice.everyreceivedmacsourcemessagestoreinMactable.inordertoonlyforwardmessagetoaddressthatlinktoswitchAddressports.forwardingunlearnmessagetoallportsonswitchMacaddressfico.Displaymac-tableinThisGUIusesfordisplayingdynamicMACaddressthatswitchThePortwithtickindicatestheforwardingpermissionfromthisportisBaudrate(floodingUnknownunicas,multicast,broadcastandoutputlimit,thisGUIusesforconfiguringstorm-control,andrestrictionforunknownunicast,multicast,broadcastandoutputlimitHit“multicast”entermulticastconfigurationGUIshownin4-18.thisGUIusesforconfiguringIGMPandInternetGroupManagementProtocol(IGMP)isamulticastprotocolinthevarietyofinternetprotocols.IGMPusesforhostsreporttheirmembershipstatustothedirectneighborrouter.IGMPinformationencapsulatedinIPpacketsandIPprotocolnumberis2IGMPprotocolusedforhostsandmulticastroutersestablishingandmaintainingmulticastgroupmembership,butnotsupportgroupmemberrelationshipinformationthattransmitaroundmulticastrouter,multicastrouteprotocolwillcompletememberrelationshipinformationtransmission,AllhostsjointinmulticastmustsupportIGMPfeature.hostscanjoinandleaveatanytime.Thereisnorestrictiononthelocationornumberofmembersinamulticastgroup.routerdonotneedandimpossibletosaveallhostsinformation.itusesIGMPprotocoltodiscoverwhetherornotthereisareceiverthadresponsemessage.thisreceivercalledgroupmember.hostonlyneedtosaveinformationofwhichgroupithasparticipatedinIGMPsentbetweenhostandrouterisunsympathetic.hostneedtoresponseIGMPquerymessagefrommulticastrouter.itisIGMPmembershipreportRouterperiodicallysendquerymessagetoauthorizemember.thenaccordingtoresponsemessage,thatconfirmaspecificgroupwhethernotorhaveahostjointedin,andwhenhostreceivesaleavemessage,routersendaspecificgroupquerymessageforcheckingwhetherornotthereisaactivememberinthegroupIGMPGlobalconfiguration:configureIGMPfeatureenableorIGMPv1:Hostscanjoinmulticastgroup;nothaveleavemessage(leavemessages);routerusestimeout-basedmechanismtodiscoverthegroupwhichothermembersdonotconcernIGMPv2:Thisprotocolcontainsleavemessages,theprotocolallowsrapidreportgroupmemberstopstatustorouteprotocol,thisisimportantforhighbandwidthmulticastormulticastgroupmemberIGMPv3:Comparedwiththeabovetwoprotocols,themajorchanges:itallowsthehosttospecifythehoststoreceivetrafficFromotherhostsinthenetworktrafficisisolated.AlsosupportsIGMPv3hoststostopthosefromnon-desiredhos dingnetworkpackets.Unknownmulticast:configureunknownmulticasttobesentorKnownMulticasts:ConfiguresendingknownmulticasttowhichEnableGMRPchangeportwhichneedsGRMPfeaturetoVlanGlobal,currentstaticandportstatusVLAN-Showversioninformation,umvlanID,maxsupportedvlans,current4-25VLAN-全局VLAN-Showcurrentvlanconfiguration4-26VLAN-當(dāng)前界面Allportsareinvlan1bydefaultVLAN-Showandconfigure4-27VLAN-靜態(tài)Press“createarticle”tocreatenewvlan,entervlanU-Untag:invlan,dispatchpacketwithouttagM-Member:invlan,dispatchpacketwithF-forbidden:notinvlan,nooptionsetup,only-:notinvlan,justModifyportvlanIDandpacket4-29VLAN-端口Portvaluerangesfrom1to4095,admittedframeadmittedallmeansnomatterpacketwithtagornot,switchforwarditadmitOnlyVlanTaggedOnlythepacketwithtagcanthoughswitchFico.ruseforsettingwhetherornotadmitalltypesofpacketsEG.Forconfiguring 1123交換機(jī)交換機(jī)12344 Inswitch1,Port1though3areconfiguredwithvlan100,vlan200andvlan300.inswitch2,port1though3areconfiguredwithvlan100,vlan200andvlan300.port4onswitch1connecttoport4onswitch2.SwatchentervlanstaticHit”new”,creatingthreevlanwithvlanID100,200and4-32VLANAddport1tovlan100,propertyisAddport2tovlan200,propertyisU;port4tovlan200,propertyisMAddport3tovlan300,propertyisU;port4tovlan300,propertyisAftermodification,press(4)Openvlanport,modifyportvlanIDtoport1,2,and3,setport1onvlan.asshownbelowAftermodificationpressset,then,saveDeleteBeforetakinganytesting,needingtodeleteormodifyexistingModifyallportsvlanIdtoAftermodification,pressOpenvlanstaticweb,deletevlan100,vlan200andChoosingavlanthenpressdelete.afterconfiguration,don’tneedtosaveconfigurationQOS/PriorityQOSisqualityofservice,anetworksecurityprotocol,isatechniqueusingforsolvingproblem,suchasnetworkdelayingandcongestionETC.ifnetworkonlyapplytospecialnon-time-limitedapplicationsystem,QOSisnotnecessary.forexample,WEBapplication,settingetc.butforkeyapplication,QOSisnecessary.whenthereiscongestion,QOScanpreventkeyapplicationfromdelayingorabandoning,aswellasensurenetworkrunninginahighefficientsituationQOSportclick“QOS/priority”“portconfiguration”accesstoQOSconfigurationGUI,thisGUIisusedforportQOS/priorityconfiguration QOS端口配Port:AssigningswitchlogicportportSettingportpriority,systempriorityvalueranges(0--7)byschedulingpriority)STRICTmode(absolutepriority)PriorityQueue01122438Queueisabufferstructureonhardware,switchsupport4queues,queueIDnumberfromlowtohighis0,1,2,3.queueIDalsorepresentthequeuepriority,thehigherweightvalue,thehigher

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論