




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
Confidentiality Specification General Commissioning Instrumentation Testing&Commissioning Commissioning MonitoringofTestingand TradePackageMethod Commissioning&Testing CheckingProceduresforBuildingServicesInstallation ContractorTesting&Commissioning Mechanical Electrical FireServices BuildingManagementandControlSystem OperatingandMaintenanceManual TrainingOfOwner AppendixA-TenderResponseCheckAppendixB-ScheduleofFAT’sand2ConfidentialityAllinformation,whethersubmittedtotheContractorbyConfidentialityAllinformation,whethersubmittedtotheContractorbytheClientorproducedbytheProjectManager,M&EConsultantorCommissioningManageronbehalfoftheClient,mustbetreatedinthestrictestconfidence.UndernocircumstancesshallinformationregardingtheClient’sprojectbeusedforanyotherpurposes.BeforeenteringintoacontracttheContractorwillbeaskedtosignaConfidentialityShouldtheContractornotwishtosigntheagreementthentheClientreservesrighttoterminate3SpecificationAppleareproposingtoundertaketheexpansionSpecificationAppleareproposingtoundertaketheexpansionandfit-outofnewapplestoreinanewlydevelopedGuangzhouCentralParkShoppingMall.DuetotheemphasistheClientplacesontheimportanceoftestingandcommissioningoftheBuildingServicestoanInternationalStandard,theyhaveengagedtheservicesofanIndependentCommissioningManager,CommtechTestingTechnology(Shanghai)Co.Ltd,whohavebeenappointedtoco-ordinateandoverseethetesting,commissioningandintegrationprocessfortheAppleGZCPInordertoensurethatthetesting,pre-commissioningandcommissioningundertakenbytheContractorsisaccomplishedinalogical,orderlyandsystematicway,theCommissioningManagementproceduresimposecertainmanagementsystemsintheplanning,installation,testing,precommissioning,commissioningandmonitoringprocess.ThisSpecificationidentifiesthecriteriathattheCommissioningManagerrequires,theteststhatwillbewitnessedandthekeyactivitiesthatnecessitatetheattendanceoftheCommissioningManager.ThisSpecificationdoesnottaketheplaceoftheM&EConsultantspecificationsbutistosupport,expandandconfirmitsrequirements.ThisdocumentshallbereadinconjunctionwiththefollowingdocumentspreparedbytheProjectManagerandtheM&EConsultantProjectManager/QSContractM&EDesignConsultantContractTheTendereristoreadandfamiliarisethemselveswiththerequirementsoftheTestingandCommissioningSpecification,SchedulesandAppendicespriortoreturningthebiddocumentation.Thereturnbidshouldincludeaseparatesectionontestingandcommissioningwherethebiddershallincludethefollowingdetailsandattachments:DetailsoftheirProposedCommissioningExecutionPlan.OrganisationChartofProposedCommissioningTeam.CommissioningTeamResourceHistogramforProject.ListsofproposedCalibratedTestInstrumentation.SampleCommissioningMethodStatement/TestRecordSheet.SamplecoordinatedCommissioningProgramme.CopyofCompletedTenderResponseCheckSheet(Appendix4GeneralNothingcontainedwithinthisdocumentshallreleaseGeneralNothingcontainedwithinthisdocumentshallreleasetheContractorsfromresponsibilitiesunderanyclausecontainedwithinthecontractdocumentation.AlthoughtheCommissioningManagerisresponsiblefortheoverseeingandwitnessingoftheServicesContractorworks,itshouldbenotedthattheContractorisresponsiblefornotifyingtheCommissioningManagerinadvanceofallteststobeAminimumof3workingdays’notificationviaaRequest-for-Inspection(RFI)form,eitherwrittenorbyemailisrequired.Thisshallincludedetailsoftheteststobewitnessed,withallrelevantMethodStatementsandTestRecordSheetscompletedandsignedbyboththeContractorsCommissioningSupervisorandCommissioningTheContractorshouldundertakeallTesting,CommissioningandWitnessing(wherepractical)duringnormalworkinghours(MondaytoFriday8:00amto6:00pm).Whereworksarerequiredtobewitnessedoutsideofnormalhoursduetonoiserestrictions,safetytootherworkersetc.oneweek’snoticeistobeprovidedtoensurewitnessingstaffcanbeavailabletoattend.ShouldtheCommissioningManager,ProjectManagerorM&EConsultantsbeunavailableforthewitnessingofanyContractortesting,itshallbetheresponsibilityoftheContractortoensurethatthetestingandcommissioningisundertakeninaccordancewiththeapprovedMethodStatementforthoseworks,andthatallresultsarerecorded.AnyclarificationsofresponsibilitiesfortestingandcommissioningshouldbesoughtfromtheProjectManagerinadvanceofinstallationworkscommencing.AlldocumentsubmissionsrelatingtoequipmentorsystemstobecommissionedshallbeissuedtotheCommissioningManagerforinformation/approvalaspartofthecontractor/suppliers’generalsubmissionprocess;thisshallincludedrawings,specifications,performancedata,pre-commissioning&testinginformationandwarrantydetails.5 CommissioningEachContractorappointedontheApple CommissioningEachContractorappointedontheAppleGZCPprojectmustcomplywiththefollowingTheContractorisrequiredtoprovidecertainkeypersonnelthroughoutthetesting,commissioning,integrationtestingandhandoverphaseoftheproject.ContractorsshallnominateaCommissioningSupervisorforeachM&Epackage.ThismemberoftheContractorsstaffshallbeconversantinMandarinandEnglish,competentandshallbeauthorisedtocoordinatetheworkwithotherparties,toattendCommissioningprogressmeetingsandtogenerallyrepresenttheContractoronallissuesrelatedtothetesting,commissioning,integrationandhandoveroftheworks.Thecontractormustensurethatallpersonnelengagedtoperformtesting;commissioningandintegrationworksarequalifiedandhaveexperienceintesting&commissioningtheirinstallationstoarecognisedstandard.ThecontractorwillberequiredtosubmitdetailedcurriculumvitaeoftheproposedCommissioningSupervisorandtesting&commissioningpersonneltotheOwnersCommissioningManageraspartoftheirtenderreturn.Shouldanyofthepersonnelchangebetweenthetenderreturndateandcommencementofsiteworks,thenthedetailsofthosePersonnelshouldbesubmittedatleastone(1)weekpriortocommencingworks.ShouldtheContractorelecttoappointaspecialistsubcontractorCommissioningCompanytoundertakehistestingandcommissioningactivities,inparticularthetesting,adjustmentandbalancingofairandwatersystemswhereapplicable,andcablingtestingofElectricalsystems,detailsofsuchcompaniesmustbesenttotheCommissioningManagerwiththetenderreturns.ShouldthatsubcontractorCompanychangebetweenthetenderreturndateandcommencementofsiteworks,thenthedetailsofanynewlyappointedsubcontractorCompanyshouldbesubmittedatleastone(1)weekpriortocommencingworks.TheuseofaspecialistCommissioningCompanybyaContractorshallnotrelievehimofhisobligationtonameoneofhisownemployeesasthepersonresponsibleformanagingofhiscommissioning.TheCommissioningManagerreservestherighttointerviewthespecialistcompaniesandcandidatesproposedforthetesting&commissioningworkssoastoensuretheyarefamiliarwiththestandardsimposed,andcanoperatetherequiredinstrumentationcorrectly.Thecontractorisrequiredtoprovideallnecessarytoolsandequipmentforhiscommissioningpersonneltoundertaketheirpackageworks.Thisshallincludeappropriateaccessequipment,PPE,safetyequipment,protectivebarriersandwherenecessary,heatloads,two-wayradios,portablelightingandtasklighting.6InstrumentationAlltestinstrumentstobeusedbyInstrumentationAlltestinstrumentstobeusedbytheContractorsforbothfactoryandsitetestingontheprojectmustcomplywiththefollowing:BeproperlycalibratedtotheappropriateregionalorinternationalBecompletewithcalibrationcertificates,notmorethansix(6)monthsold,andissuedbyarecognisedindependenttestingauthority.Copiesofallcalibrationcertificates,togetherwithinstrumentserialnumbersshallbesubmittedtotheCommissioningManageraspartoftheContractorsMethodStatementforhisworkspriortotheiruseon-site.Befreefromdamage,andifdamagedduringtheprojectlifeshallberecalibrated,withnewcalibrationcertificatessubmitted.Becompletewithallmanufacturers’ItistheresponsibilityoftheContractortosupplyanyspecialistTestInstrumentationorequipmentrequiredtoperformtesting&commissioningworksinaccordancewithStatutoryCodesandRegulations.7Testing&CommissioningEachContractorwillTesting&CommissioningEachContractorwillberequiredtoproduceaprogrammedetailingeachelementoftheirworksfrominstallation,throughtesting&commissioningandIntegratedSystemstestingtohandoverandacceptance.EachTradeContractorprogrammeshalldetailtimedurationsforeachelementoftheirworks.TheCommissioningManagershallproduceanoveralltesting&commissioningtargetprogrammebasedonthecontractorprogrammedates.ThetargettestingandcommissioningprogrammewillbebasedontheagreedlogicdiagramsandContractorprogrammesandworksdurations.Itmustberecognisedthatinordertoproduceaco-ordinatedprogramme,thesequencingofthecontractorworkswillbeadjustedifrequiredtosuittheoverallprojecttargetdates.TheProjectM&Esystemsinstallation,testing,commissioningandIntegratedSystemsTestingwillhavetobecarefullycoordinatedbetweentheM&EContractorsworks,andduerecognitionofthismustbetakenintoaccountbytheContractorsinvolvedwhenprogrammingtheirworks.EachContractorwillberequiredtoupdatethestatusoftheirworksagainsttheirsubmittedinstallation,testingandcommissioningprogrammes.Thisdatawillbeusedtoupdatetheoveralltargettestingandcommissioningprogrammetoshowtheprogressoftheproject.8CommissioningTheCommissioningManagershallmeetwitheachContractorCommissioningSupervisoronaweeklybasisfromprojectcommencement.EachContractorCommissioningSupervisorwillreporttheprogressfortheirpackageattheseOnceservicesinstallationshavecommenced,therewillbeabi-weeklygeneralCommissioningmeeting,whichwillbecomeaweeklymeetingastheprojectprogresses,thatwillprovidetheforumfordiscussionofdesignandinstallationproblemsaffectingtestingandcommissioningoftheprojectservices.EachContractorCommissioningSupervisorwillbeexpectedtoattendeverycommissioningmeeting.EachContractorCommissioningSupervisorCommissioningTheCommissioningManagershallmeetwitheachContractorCommissioningSupervisoronaweeklybasisfromprojectcommencement.EachContractorCommissioningSupervisorwillreporttheprogressfortheirpackageattheseOnceservicesinstallationshavecommenced,therewillbeabi-weeklygeneralCommissioningmeeting,whichwillbecomeaweeklymeetingastheprojectprogresses,thatwillprovidetheforumfordiscussionofdesignandinstallationproblemsaffectingtestingandcommissioningoftheprojectservices.EachContractorCommissioningSupervisorwillbeexpectedtoattendeverycommissioningmeeting.EachContractorCommissioningSupervisorshallreporttheprogressoftheirworksandhighlightanyproblemstheyhaveencounteredandanyproblemstheyforesee.Progressoftheirworksshouldbedetailedonagreedinstallation;testingandcommissioningprogrammes(seeSection6.0–Testing&CommissioningAtthecommissioningmeetings,eachContractorwillgiveatwo(2)weeklookaheadfortheirworks.EachContractorshallreportrequirementsofinterfaceswithotherContractorse.g.MechanicalandBMCSinterfacesforcontrolvalveanddamperpositions,BMCSandElectricalInterfacesforPowermonitoringpoints.TheContractorCommissioningSupervisorshallalsoattendfocusmeetingsasrequiredforthediscussionandcoordinationofspecifictestingandcommissioningDetailsandrequirementsofanytestequipmentortemporarycableinstallationsthatrequirespecialaccessroutesorenvironmentalconditionsshallbesubmittedtotheCommissioningManageratleast14dayspriortorequiredinstallationonsite.9MonitoringofTestingandDuringthedurationoftheproject,MonitoringofTestingandDuringthedurationoftheproject,theContractorswillundertakeavarietyoftestingandcommissioningtasks.Thesewillincludeinitialtestingduringtheinstallationphaseoftheproject,pre-commissioningandfinalcommissioningofallM&EandLifeDuringtheinstallationphaseoftheproject,theContractorswillcarryoutinitialtestingandprecommissioningofallM&EandLifeSafetyServicesandsystems,followedbyfinalcommissioningandIntegratedTestingandEnvironmentalproving.ThisshallincludethePressuretesting,flushingandcleaningofpipework/ductwork,proportionalbalancingofairandwatersystemsforMechanicalsystems,testingofElectricalinstallationsbothbeforeandafterpowerhasbeenenabled,andcable/softwaretestingofLifeSafety,BMCSandcontrolsystems.ItisvitalthatduringtheseperiodsanaccuratestatusoftheprogressisdocumentedsothatthefollowingContractorscanproceedto‘closein’thefirstfixdistributionserviceswithoutdelay.Thetargettesting&commissioningprogramme,markedupdrawings,schematicsandfloorplanswillbeutilisedtomonitortheprogressofthetesting.ThesewillbemaintainedintheCommissioningManager’ssiteofficeandwillbeavailableforcheckingbyallparties.Colourhighlightedschematicservicesdrawingswillindicatewhereasystemhasbeentestedandcross-referencewillbemadetotherelevanttestcertificateThecontractorisrequiredtoassistthisprocessbyprovidingthefollowinginformationtotheProjectCommissioningManageronaweeklybasis:Simplebulletpointreportadvisingprogress/deviationfromprogramme/problemsandcausesfordelay.Listofmajorplant/equipment/panel–Delivery/Markedupschematics/drawingsshowingprogressofsuccessfulPressureTestofpipework,InsulationResistanceTestingofCables.UpdatedlistoftestingTradePackageMethodTheContractormethodstatementswillbethebasisTradePackageMethodTheContractormethodstatementswillbethebasisofallfactoryandon-siteThemethodstatementtobesubmittedmustbeprojectspecific,andnotastandardissuedocument.Asaminimum,themethodstatementshouldincludethefollowingTheprojecttitleandareaorAfullDetailsofthesystemstobeMethodsandproceduresofAlistofthespecifiedperformancecriteriatobePro-formatestTheseriesofcodesidentifyingthestandardtowhichtaskswillClear,detailedrequirementsfromotherTradeAscheduleofinstructionstobeThemethodstatementmustclearlyidentifytheCommissioningSupervisorfortheproject.ThispersonwillbeamemberofstaffotherthantheContractorProjectMethodstatementsaretobesubmittedforapprovaltotheCommissioningManager,allowingsufficienttimeforreview,commentandre-issue.TheMethodStatementsmustachieveapprovedstatuspriortothecommencementofanycommissioningandtestingactivities.ApprovalbytheprojectteamwilltaketheformofA,BorCstatus.Thesearedefinedbelow:AStatus–ApprovedbytheprojectteamandworkscanproceedinaccordancewiththeMethodStatement.BStatus–CommentsbytheprojectteamaretobeincludedintotheMethodStatementandresubmitted.CStatus–MethodStatementrequiresrevisinginfull,asitdoesnotmeetrequirement,andmustberesubmitted.Commissioning&TestingContractorsshalldevelopspecifictestingandcommissioningmethodstatementsandsubmitforapprovalbytheprojectteam.Allappendedtestrecordsheetsmustcontainallapplicablecorrectionfactors,andmustbeformattedtoincludethenameandsignatureoftheContractorCommissioningCommissioning&TestingContractorsshalldevelopspecifictestingandcommissioningmethodstatementsandsubmitforapprovalbytheprojectteam.Allappendedtestrecordsheetsmustcontainallapplicablecorrectionfactors,andmustbeformattedtoincludethenameandsignatureoftheContractorCommissioningSupervisor,Contractorcommissioningengineerandthedateofthetest.TestsheetsmustalsoincludeprovisionfortheClient’sCommissioningManagertosignoffthetestasacceptable.Priortoplantbeing‘settowork’,allmanufacturersliteraturerelevanttothesystemcommissioningshallbeavailable,andapreventativemaintenancescheduleTheContractorsshallarrangeforcopies(inbothMandarinandEnglish)ofthecertifieddatatobeavailable,sothattheCommissioningManagercanretaincopiesofalldocumentation.ShouldtheCommissioningManager,forwhateverreason,beunavailabletoattendatestdemonstration,theContractorshallutiliseTimeandDatestampedPhotographicrecordsoftestingandcommissioning.TheseshallbeproducedbytheContractorandsubmittedtotheCommissioningManageralongwithtestingandcommissioningrecords.AnytestsnotwitnessedbytheCommissioningManager,M&EConsultantsorProjectManager,andthathavenophotographicevidenceoftesting,mayhavetoberepeated.ThisshallbeatthediscretionoftheCommissioningManager.ItshouldbenotedthattheOwner,ProjectManagerandM&EConsultantmayalsobeinattendanceatkeystagesofthewitnessing.InadditiontothestandardsandcodesofpracticestatedelsewhereinthisdocumentandintheM&EConsultantTechnicalspecifications,theContractors’attentionisdrawntothefollowingpublicationsforCommissioningandtestingworks:HVCAGuidetogoodpracticeforsitepressuretestingofpipework–BSRIAApplicationGuideAG1/2001.1–Flushing&CleaningofWaterSystems-2004BSRIAApplicationGuideAG2/89.3-Commissioningofwatersystemsinbuildings–2002CIBSECodeW–WaterDistributionSystems–CIBSECodeR-Refrigeratingsystems–CIBSECodeA-AirDistributionsystems–HVCADW/143DuctworkLeakageBSRIACIBSECodeR-Refrigeratingsystems–CIBSECodeA-AirDistributionsystems–HVCADW/143DuctworkLeakageBSRIAApplicationGuideAG3/89.3-Commissioningofairsystemsbuildings–2001CIBSECommissioningCodeC:2001-AutomaticBSRIAApplicationHandbookAH3/92-Installation,commissioningmaintenanceofFireandSecuritysystemsPt1-3–1992&CIBSECommissioningCodeL:2003LightingGB50242-2002GB50243-2002GB50591-2010-GBJ148-90CECS100:98GB50169-2006GB50170-2006GB50173-92電氣裝置安裝工程35KVGB50171-92電氣裝置安裝工程盤,GB50312-2007GB50261-2005TheCommissioningManagershouldbeinformedofanyadditionalCodesand/orStandardsthattheContractorutilizesfortesting&commissioningpurposesviatheappropriateMethodStatementdocumentation.CopiesofanyclausesrelevanttothetestsbeingofferedshallbesubmittedtotheCommissioningManagerinEnglishLanguageforcomment.ThecontractorshouldnotethatwhereGB,CIBSEandBSRIAcodescrossover,thecodewiththehighestspecificationmustbeused.CheckingProceduresforBuildingServicesInstallationToensurethattheAirSystemsinstallationiscompleteCheckingProceduresforBuildingServicesInstallationToensurethattheAirSystemsinstallationiscompletetheContractorshallAirintakescreensandlouvresareunobstructedandFanandotherequipmentchambersarecleanandfreeofdustandconstructionFanshavebeencheckedforimpellerhousingclearanceandarefreeofforeignDampersarecleanandinthenormalfullyopenedorclosedpositions,(FreshAirandExhaustAirdampersfullyopen,Recirculationdampersfullyclosed).Ductingandotherairwaysarecleaned.DuctpressuretestingiscompleteandAllelectricalwiringcircuitsarecompleteandatthecorrectstageduringthecommissioningsequence.AdequatelightingisTheinstallationcontractorshallalsoensurethatallequipmenthasbeencheckedEquipmentrotation(Pulsedonly).Belttension.Ductflexibleconnectionscorrectlyaligned.Keywayandsetscrewtightness.CleanVibrationisolationadjustmentandremovalofalltransitbolts.Fanimpellerbalancesatisfactory.CorrectoverloadrangeandamperageThelocationofallstop-start,disconnectionandcircuitinterruptiondevicesSatisfactoryperformanceconditionshavebeenachievedforfaninlet/outlet.Alloutsideair,returnairandspillairdampersareoperational(manuallyorAllfireandvolumecontroldampershavebeenfittedandhavebeenleftinthefullyopenposition.Firedampershavethecorrectfusiblelinkrating.Thesupplyairsysteminletanddischargeairchambershavebeenclearedoutpriortostartofequipment.Allplenumboxesandgrilleshavebeenfittedandtheirdampersleftfullyopen.Allfiltermediaisinstalledandclean.Theserviceinstallationswillbeundercontrolofthe‘permittowork’pre-commissioningcheckswillberecordedontherelevantsheetswithinthespecification.ThesewillbesignedoffandcertifiedbytheAllsystemswillhaveinitialreadingstakenandanydiscrepanciesdiscussedwiththeM&EConsultingEngineerandCommissioningManager.Thisshouldmitigatepotentialdelays.ToensurethattheWaterSystemsinstallationiscompletetheMainContractorshallcheckthat:ToensurethattheWaterSystemsinstallationiscompletetheMainContractorshallcheckthat:FloorgulliesandalldrainagetraysarecleanandAllcondensatepipeworkisinstalledandall‘U’or‘P’trapsarefittedandfilledwithwater.Coolerbatteriesarecleanandtheirfinscombedstraight.Coolingdriptraysareclean.PressuretestingandchemicalcleaningiscompletetothesatisfactionoftheM&EConsultingEngineer,ProjectManagerandCommissioningManager.Allelectricalwiringiscompleteandatthecorrectstageduringthecommissioningsequence.AdequatelightingisUninterruptedpowersuppliesareavailableattheelectricalpanelstoenablealltheconnectedequipmenttobesatisfactorilycommissioned.WhereapplicableallcontrolvalvesareelectricallydriventotheirfullflowWhereapplicableallstrainersarecleanandhaveremainedcleanduringsystemrunning(aperiodof5daysisrecommended).Whereapplicableallsystemshavebeenflushed,filledandWhereapplicableallFeedandexpansiontanksaretobesettoworksuchthatastablesystemismaintained,althoughfinalcommissioningcanbecarriedoutpostsystembalancing.WhereapplicableallWatertreatmentprocedureshavebeencarriedoutandarebeingmonitored.Condensatedriptrayoperationhasbeensuccessfullytestedandthespecification.ContractorTesting&CommissioningTheContractorwillberequiredtoliaisewithrespectivecommissioningteamsfromothervendorsandcontractorstoensurethattheoverallcommissioningprocessiscompletedinalogicalsequence.Theseinterfacesarelikelytoincludebutnotbelimitedtothefollowing:Cableterminations,ContractorTesting&CommissioningTheContractorwillberequiredtoliaisewithrespectivecommissioningteamsfromothervendorsandcontractorstoensurethattheoverallcommissioningprocessiscompletedinalogicalsequence.Theseinterfacesarelikelytoincludebutnotbelimitedtothefollowing:Cableterminations,finalcircuittests&energisation.FireAlarmSystemInterfaces.BMCSControls&PQMSLoadtestingwithcombinedtestswherepracticable.PowerFailureScenarioTestsIntegratedSystemTests–AFACause&TheContractorshallalsoberequiredtoprovideinterfacingwiththeClient’sexistingequipmentandsystems.AresponsibilitymatrixdetailingthevariousinterfaceswillbecollatedbyMechanicalTheContractorshallprovideadetailedinventoryMechanicalTheContractorshallprovideadetailedinventoryofallthecommissioningequipmentheldon-site,priortouse,totheCommissioningManagerforinspectionandRecommendedtestequipmentformechanicaltestingincludesbutisnotlimitedtothefollowing:AirflowBalometer/PitotTubeandElectronicMicromanometerElectronicVaneAnemometer(VelocityMeter)Clamp-onAmmeter(ACCurrent)Tachometer(RotationalSpeeds)PressureGauge/sMultimeter(Voltage/Resistance)PhaseRotationMeterDuctLeakagetestPre-CommissioningofMechanicalBeforeanypre-commissioningchecksarecarriedout,boththenominatedCommissioningSupervisorfromeachContractorandtheLandlord(Ifnecessary)shallformallycertifythattheinstallationiscompleteandreadyforpre-commissioningcheckstocommence.Pre-commissioningchecksshallgenerallybeasdetailedinthespecificMethodStatementforthattask.TheContractorsshallproducefinaldocumentationrecordingthatpre-commissioningcheckshavebeencarriedout.TheLandlordand/orContractorCommissioningSupervisorshallapprovethissigneddocumentationasacceptablebeforeitbeingofferedtotheCommissioningManagerforapproval.Nocommissioningshallbecarriedoutuntilallpre-commissioningcheckshavebeenrecordedandapproved.Allplantareasandequipmentshallbecleanbeforepre-commissioningandallequipmentshallbecheckedforthecorrectoils,greaseetc.beforestarting.Priortopre-commissioningchecks,defectsheetsshallbepreparedbytheContractorandsubmittedtotheCommissioningManagerforsignature.TheContractorswillcomplywithany‘permittowork’systemsand‘limitationsofaccess’systemsoperatedbytheClientortherelevantContractor,undertheoveralldirectionoftheProjectManager.AirDuctworkLeakageAirleakagefromductedairdistributionsystemsAirDuctworkLeakageAirleakagefromductedairdistributionsystemsisanimportantconsiderationintheoperationofairconditioningsystems.Asystemthathaslimitedairleakage,withinacceptablelimits,willensurethatthesystemdesignparameterscanbemaintained.Itisarequirementofthecontractthattheductedairdistributionsystemispressuretestedtomeasuretheamountofairleakage.ThisshallbecarriedoutinaccordancewiththerelevantStandardsandCodes.Leakageoccursfromsheetmetalductworkattheseamsandjointsandisproportionaltothetotalsurfaceareaoftheductworkinthesystemandtheairpressureinsidetheduct.Excessiveleakagefromductworkcancauseairnoiseandaffectthesystemperformance.TheContractorshallsupplyandinstallallrelevantblankingdevices(e.g.heavydutypolythenesheeting)andotherequipmentnecessaryforthefullandcompletetestingoftheselectedareasofductworktobetested.TheContractoristoensurethatalltestpointsandblankingdevicescanbereachedwithoutdifficulty.Oncompletionofsectionsoftheductworkinstallation,itshallbeleakagetestedbythecontractorasrequiredbytheSpecification.Beforeundertakingairleakagetesting,theContractorshallsubmitamethodstatementtotheCommissioningManagerdetailingtheproposedtestPrimaryAirHandlingUnit(PAU)/AirHandlingUnitsPAU/AHUandtheircontrolsystemsshallundergopre-commissioningandfullsitecommissioningtests.AlltestswillbecarriedoutbytheContractor.FanCoilAllfancoilunitsshallbetestedtoprovetheiroperationandperformance,includingsafetyinterlocks,BMCSsignalsandnoiselevels.Supply/ExtractFanAllsupplyandextractfanswillbeperformancetestedtoprovetheirProportionalBalancingofLowVelocityOncompletionofallworksassociatedwiththelowvelocityairinstallation,includingallairhandlingplant,terminalunitsandgrilles,theairsystemsshallbebalanced.Proporti
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 單位整修合同范本
- 2025年天津從業(yè)資格證貨運題庫答案大全
- 關(guān)于消防器材購買合同范本
- 企業(yè)聯(lián)營合作合同范本
- 醫(yī)美手術(shù)合同范本
- 單位公車出租合同范本
- 加高工程合同范本
- 農(nóng)戶合同范本
- 劇組服裝采購合同范本
- 共享單車租金合同范本
- 《體育開學第一課:體育常規(guī)教育》課件
- 上海市高新技術(shù)成果轉(zhuǎn)化項目認定申請書
- 休閑體育小鎮(zhèn)規(guī)劃方案
- 海南紅色拓展培訓方案
- 鎂合金汽車輪轂的研究與開發(fā)
- 新能源船舶動力系統(tǒng)的工程實踐
- SHAFER氣液聯(lián)動執(zhí)行機構(gòu)培訓
- 小學生守則、日常行為規(guī)范教育實施方案
- 湖南省六年級上冊數(shù)學期末試卷(含答案)
- 部編版小學六年級道德與法治下冊課堂達標檢測試卷全冊含答案
- 巖土工程中的非線性問題分析
評論
0/150
提交評論