00159Introduction of PONY LAB_第1頁(yè)
00159Introduction of PONY LAB_第2頁(yè)
00159Introduction of PONY LAB_第3頁(yè)
00159Introduction of PONY LAB_第4頁(yè)
00159Introduction of PONY LAB_第5頁(yè)
已閱讀5頁(yè),還剩19頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

1、may 11, 2004song wei1stinternational symposuim on green manufacturingponylabintroduction ofpony labsong weibeijing pony labmay 11, 2004song wei1stinternational symposuim on green manufacturingponylabbeijing pony center for physical and chemical analysispony lab is accredited by china national accred

2、itation board for laboratories and beijing bureau of quality and technical supervision respectively, to the international standard iso/iec 17025. accreditation certificate of cnal (no. l0412)song weicma certificate(2002) (z0407)certificate by motorolaponylabmay 11, 20041stinternational symposuim on

3、green manufacturingcertification of motorolapony labhas been appointed by motorola inc.to be the only one materials assay laboratory in china and was awarded motorolas best project cooperation matein 2003.may 11, 2004song wei1stinternational symposuim on green manufacturingponylabqa/qc in pony labin

4、ternal audits are organized by selecting appropriate test samples for a given test standard and given employee to check the testing result compliance.inter-laboratory comparisons are implemented to ensure the quality and reliability of test results, internal auditsand monitor the performance of our

5、labs.proficiency testingall equipment used for testing and inspection is regularly calibrated to ensure measurements are traceable to calibrationnational and international standards.trainingput great emphasis on the ability of all employees performing any testing or inspection task. accreditationmay

6、 11, 2004pony lab is accredited to the international standard iso/iec 17025 by cnal and bbqts.song wei1stinternational symposuim on green manufacturingponylabeu directives-the driving forceas the release of the well-known weee and rosh directives, all the electrical and electronic equipment covered

7、in weee can not contain hazardous substances( pb, hg, cd, cr(vi), pbb, and pbde ) mentioned in rosh since july 1st, 2006.according to the eu directives we have firstly begun to analyze these substances in electronic, home appliances, wiring and packaging materials for many multinational and chinese

8、companies.our ultimate purpose is to provide manufacturers with quick and accurate material testing services, to help the clientele develop newly environmental-friendly raw materials to improve the product export competency.song weimay 11, 20041stinternational symposuim on green manufacturingponylab

9、testing capabilitytesting itemscontentheavy metals inorganic chemicals chlorinated organic compounds brominatedorganic compounds organic tin compounds others cadmium and its compounds, lead and its compounds, mercury and its compounds, hexavalent chromium compoundssb, p, sn, as, ba, se, ti, ta, au,

10、ag, cu, zn, be, ni, br, clpcbs, pcts, pcns, cps, mirex, other organochlorine compoundspbbs, pbdes, tbbal-a-bis, other organobromine compoundsmonobutyl tin, dibutyl tin, tributyl tin, triphenyl tinasbestos, azo compounds, formaldehyde, polyvinyl chloride and its blends, paraffin hydrocarbons, halogen

11、ated hydrocarbons, polycyclic aromatic hydrocarbons, and other organic compounds etc.may 11, 2004song wei1stinternational symposuim on green manufacturingponylabtesting equipment and methodstesting itemspb and its compoundsmercury and its compoundscadmium and its compoundschromium(vi) compoundspbbs/

12、pbdespcbsorganic tin compoundsformaldehydeasbestosazo compoundspb,hg,cd and cr(vi)in packaging materialsequipmenticp-aesicp-aesicp-aesuv-visgc-msgc-ecd/ms gc-fpduv-vis / hplcft-irgc-ms / tlcicp-aes & uv-vissong weimethods & regulationsus epa 3050bus epa 3052en 1122:2001, 91/338/eecus epa 3060a & 719

13、6a83/264/eecus epa 8082, 89/677/eec89/677/eecen 120 / din 5331583/478/eec, 85/610/eec, 91/659/eec35 lmbg 82.02.2 / 35 lmbg 82.02.3 /35 lmbg 82.02.494/62/eecponylabmay 11, 20041stinternational symposuim on green manufacturingtesting scopeelectrical and electronic equipment covered in weeelarge househ

14、old appliancessmall household appliancesit & telecommunication equipmentconsumer equipmentlighting equipmentelectrical and electronic toolstoysmedical equipment systemmonitoring and control instrumentsautomatic dispensersmay 11, 2004song wei1stinternational symposuim on green manufacturingponylabele

15、ctronic products and materials assaysong wei , jim liu , liang xia , qian chunyan , etc.beijing center for physical and chemical analysis beijing pony center for physical and chemical analysisbeijing, chinamotorola,inc.may 11, 2004song wei1stinternational symposuim on green manufacturingponylabresea

16、rch background and objectthe european parliament enacted directives weee and rosh for dealing with end-of-life electrical goods in order to reduce the content of hazardous substances in waste, to preserve, protect and improve the quality of the environment. relative chinese regulation “management me

17、thods for prevention control of pollutions from production of electronic information products” was released by china electrical information ministry to control harmful substances content in electrical and electronic products.our purpose is to establish a rapid, accurate, reliable analytical method f

18、or the four heavy metals ( pb, hg, cr, cd ) and pbbs / pbdes existed in real electrical and electronic products.song weimay 11, 20041stinternational symposuim on green manufacturingponylabdevelopment of analytical methodsmethods developed for:elemental analysis including pb, cr, cr(vi), cd, and hgsu

19、bstance analysis for phthalates, brominated flame retardants, and organotin stabilizersmethod for the localization of materials on a pwb that prevenrecyclingmaterial assay test methods for rapid sorting of plasticsincluding additiveson-site material assay test method for pb in cablessong weimay 11,

20、20041stinternational symposuim on green manufacturingponylabresearch content for heavy metal testingcompared common wet digestion and microwave digestion methodsoptimized microwave digestion procedurecompared aas and icp-aes as the two most commonly-used determination methodsmay 11, 2004song wei1sti

21、nternational symposuim on green manufacturingponylabcomparison of two digestion methodsresults of two different digestion methods. concentration were determined by icp-aes.elements method 1 recovery method 2 recovery(mg/l) (%) (mg/l) (%)pb cd cr hg 58.6 90.1 61.8 0.002 93.4 0.0036 112.40.25 89.7 0.4

22、5 99.7n.d. 87.6 0.005 108.994.8note: method 1 is the common wet digestionmethod 2 is microwave digestionsong wei.ponylabmay 11, 20041stinternational symposuim on green manufacturingcomparison of two microwave digestion proceduresdigestion programs 1 and 2 used with microwave digestionprogram power (

23、w) time (min)program 1(35min)step 1 500 step 2 1200 step 3 0 program 2 (50min)step 1 200 step 2 400 step 3 600 step 4 0 test result showed that program 1 has a higher extraction efficiency within a shorter time.song weimay 11, 20041stinternational symposuim on green manufacturing51515 5 102015ponyla

24、bcomparison of aas and icp-aes on the analysis of pb, hg, cd, crboth methods relied on combustion flames or electrothermalmethods to atomize and introduce the sample into the optical path and to free the analytes from other substances generally present in a solution. a sample solution was sprayed as

25、 an aerosol through a nebulizer into the flame. unlike other spectrometry methods for solutions or solids, both aas and icp-aes deal with extremely sharp spectra lines. the accuracy of aas was better than icp-aes while analysis time was shorter by icp-aes, especially for multiple elements.song weima

26、y 11, 20041stinternational symposuim on green manufacturingponylabmethod precisionprecision characterizes the reproducibility of the results.generally the relative standard deviation (rsd) is regarded as the criterion to evaluate the precision. herein the rsd was calculated by the software, so the r

27、sd was higher than ever. a t-test was carried out at each concentration to compare the mean with the true or given value. this showed if there were statistically significant differences. song weimay 11, 20041stinternational symposuim on green manufacturingponylabcalibration recovery for cdcdcdfound=

28、3.185e-5+0.955*x+epsfound=3.185e-5+0.955*x+epsgiven=0+1*x+epsgiven=0+1*x+eps.01.01.007.007.005.005.003.0030.0010.001-0.0010.0010.0030.0050.0070.009-0.0010.0010.0030.0050.0070.009given(wt %)given(wt %)0.0110.011foundfoundgivengivenfigure 1 - calibration recovery for cd (regression (blue) and ideal line (red) dotted line: confidence interval (95%) the ideal line was within the confidence interval. so the result of figure 1 shows that the measurements fo

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論