1、CHECK LISTDate:Checked By:Villa EntryOPSProjectItemsRemarksDate Inspected:Inspected By:Date Inspected:Inspected By:All excess paint to be removed from access walkway.Remove all excess paint overspray on wall from bamboo screen treatment at entry doorway.No ground/earth wire provided to light fitting

2、.Exposed cabling, need to cover by installing wires in conduit and paint to match wall finish color.Entry door does not keep rain water out, floor very slippery when water inside and door rattles in wind at night and is disturbing.To provide a weather strip on bottom of door and a seal to be applied

3、 to the door frame to prohibit 'rattling' in wind.CHECK LISTDate:Checked By:Mechanical RoomOPSProjectItemsRemarksDateChecked By:DateChecked By:Aircon unit not installed properly, it is at an angle across the plant room and therefore air flow across the coils is not as good as it should be, a

4、dditionally the hot exhaust air is re-circulated inside the room and decreases efficiency of the unit.No cover on MATV junction box, individual circuits are not labeled either at the terminal box or inside the guest room wall plates for ease of identification.Exposed wiring and terminations to be re

5、placed and all terminations made in approved junction boxes.Electrical switch board circuits not labeled and no safety cover plate with circuit breakers identified.Voice and Data cabling not installed properly (blue cable).Hot and Cold water supply isolation valves not labeled.Air-conditioning scree

6、n not installed properly.CHECK LISTDate:Checked By:Room Inside/ Main Living RoomOPSProjectItemsRemarksDateChecked By:DateChecked By:Paint marked and stained on the wall beside TV.Water damage around window beside TV, suspect poorly installed window frame - to be inspected and addressed.TV cabinet da

7、mage.Mini bar not installed with good ventilation and unit operating very hot which will reduce service life of unit prematurely. Recommend to cut second slot for natural air circulation.Safety box to be secured by bolting down onto the drawer unit in the wardrobe.CHECK LISTDate:Checked By:BathroomO

8、PSProjectItemsRemarksDateChecked By:DateChecked By:Hand basin water leak.Bathroom and toilet entry doors - handles are corroding badly and finish is unacceptable. Recommend to replace all bathroom hardware fittings with better quality.Bathroom shower and toilet doors are of low quality finish, lamin

9、ate imitation wood veneer surfacing coming off doors Recommend doors are replaced with solid wood.Drain not connected properly.Note: Water pressure modulating, its not constant and needs to be addressed through the plant room domestic cold and hot water system checks.Bathroom tub drain not connected

10、 properly. Bathtub moving on floor inside bathroom and in most cases the drain connection is 'proud' of the floor so the tub floor is not flat and water 'ponds'.CHECK LISTDate:Checked By:Bathroom window - exterior screeningOPSProjectItemsRemarksDateChecked By:DateChecked By:External

11、window frame needs to be cleaned of over paint finish and properly painted.Excess wire noted on many exterior bathroom structures from construction, these need to be removed and the structures painted to a clean finish.CHECK LISTDate:Checked By:Ceiling space above bedOPSProjectItemsRemarksDateChecke

12、d By:DateChecked By:Coadunate drain line and drip tray not installed properly. If the condensate drain is not installed with a 'fall' from the catchment tray down to the main drain line then water will 'flood' the tray causing serious ceiling damage over time.Recommend that the trays

13、 and drains are tested during snagging by filling trays artificially with a water form a jug to ensure trays can drain before handover completed.CHECK LISTDate:Checked By:Deck AreaOPSProjectItemsRemarksDateChecked By:DateChecked By:Composite wood finish surrounding the Jacuzzi is not finished safely

14、.Recommend to change material for timber decking.Back terrace exterior light fitting rusting, cables exposed and to be installed inside conduit painted color as the wall finishes.External lights fitting crowded.Feature light no access to replace bulb, contractor provide method statement.Jacuzzi parts missing like headrests and overflow covers - these need to be replaced by contractor before handover.CHECK LISTDate:Checked By:Air condition

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論