1、Good is good, but better carries it.精益求精,善益求善。FDA微生物化驗(yàn)室的檢查指南英文稿-GUIDETOINSPECTIONSOFMICROBIOLOGICALPHARMACEUTICALQUALITYCONTROLLABORATORIESNote:ThisdocumentisreferencematerialforinvestigatorsandotherFDApersonnel.ThedocumentdoesnotbindFDA,anddoesnotconferanyrights,privileges,benefits,orimmunitiesforo
2、ronanyperson(s).I.INTRODUCTIONTheGuidetotheInspectionofPharmaceuticalQualityControlLaboratoriesprovidedverylimitedguidanceonthematterofinspectionofmicrobiologicallaboratories.Whilethatguideaddressesmanyoftheissuesassociatedwiththechemicalaspectoflaboratoryanalysisofpharmaceuticals,thisdocumentwillse
3、rveasaguidetotheinspectionofthemicrobiologyanalyticalprocess.Aswithanylaboratoryinspection,itisrecommendedthatananalyst(microbiologist)whoisfamiliarwiththetestsbeinginspectedparticipateintheseinspections.II.MICROBIOLOGICALTESTINGOFNON-STERILEPRODUCTSForavarietyofreasons,wehaveseenanumberofproblemsas
4、sociatedwiththemicrobiologicalcontaminationoftopicaldrugproducts,nasalsolutionsandinhalationproducts.TheUSPMicrobiologicalAttributesChapterprovideslittlespecificguidanceotherthanThesignificanceofmicroorganismsinnon-sterilepharmaceuticalproductsshouldbeevaluatedintermsoftheuseoftheproduct,thenatureof
5、theproduct,andthepotentialhazardtotheuser.TheUSPrecommendsthatcertaincategoriesberoutinelytestedfortotalcountsandspecifiedindicatormicrobialcontaminants.Forexamplenaturalplant,animalandsomemineralproductsforSalmonella,oralliquidsforE.Coli,topicalsforP.aeruginosaandS.Aureus,andarticlesintendedforrect
6、al,urethral,orvaginaladministrationforyeastsandmolds.Anumberofspecificmonographsalsoincludedefinitivemicrobiallimits.Asageneralguideforacceptablelevelsandtypesofmicrobiologicalcontaminationinproducts,Dr.DunniganoftheBureauofMedicineoftheFDAcommentedonthehealthhazard.In1970,hesaidthattopicalpreparati
7、onscontaminatedwithgramnegativeorganismsareaprobablemoderatetoserioushealthhazard.Throughtheliteratureandthroughourinvestigations,ithasbeenshownthatavarietyofinfectionshavebeentracedtothegramnegativecontaminationoftopicalproducts.TheclassicalexamplebeingthePseudomonascepaciacontaminationofPovidoneIo
8、dineproductsreportedbyahospitalinMassachusettsseveralyearsago.Therefore,eachcompanyisexpectedtodevelopmicrobialspecificationsfortheirnon-sterileproducts.Likewise,theUSPMicrobialLimitsChapterprovidesmethodologyforselectedindicatororganisms,butnotallobjectionableorganisms.Forexample,itiswidelyrecogniz
9、edthatPseudomonascepaciaisobjectionableiffoundinatopicalproductornasalsolutioninhighnumbers;yet,therearenotestmethodsprovidedintheUSPthatwillenabletheidentificationofthepresenceofthismicroorganism.ArelevantexampleofthisproblemistherecallofMetaproterenolSulfateInhalationSolution.TheUSPXXIImonographre
10、quiresnomicrobialtestingforthisproduct.TheagencyclassifiedthisasaClassIrecallbecausetheproductwascontaminatedwithPseudomonasgladioli/cepacia.Thehealthhazardevaluationcommentedthattheriskofpulmonaryinfectionisespeciallyseriousandpotentiallylife-threateningtopatientswithchronicobstructiveairwaydisease
11、,cysticfibrosis,andimmuno-compromisedpatients.Additionally,theseorganismswouldnothavebeenidentifiedbytestingproceduresdelineatedinthegeneralMicrobialLimitssectionoftheCompendia.TheUSPcurrentlyprovidesforretestsintheMicrobialLimitssectionhoweverthereisacurrentproposaltoremovetheretestprovision.Aswith
12、anyothertest,theresultsofinitialtestshouldbereviewedandinvestigated.Microbiologicalcontaminationisnotevenlydispersedthroughoutalotorsampleofproductandfindingacontaminantinonesampleandnotinanotherdoesnotdiscountthefindingsoftheinitialsampleresults.Retestresultsshouldbereviewedandevaluated,andparticul
13、aremphasisshouldbeplacedonthelogicandrationaleforconductingtheretest.Inordertoisolatespecificmicrobialcontaminants,FDAlaboratories,aswellasmanyintheindustry,employsometypeofenrichmentmediacontaininginactivators,suchasTweenorlecithin.Thisisessentialtoinactivatepreservativesusuallypresentinthesetypeso
14、fproductandprovidesabettermediumfordamagedorslowgrowingcells.Othergrowthparametersincludealowertemperatureandlongerincubationtime(atleast5days)thatprovideabettersurvivalconditionfordamagedorslow-growingcells.Forexample,FDAlaboratoriesusethetestproceduresforcosmeticsintheBacteriologicalAnalyticalManu
15、al(BAM),6thEdition,toidentifycontaminationinnon-steriledrugproducts.Thistestingincludesanenrichmentofasampleinmodifiedletheenbroth.Afterincubation,furtheridentificationiscarriedoutonBloodAgarPlatesandMacConkeyAgarPlates.Isolatedcoloniesarethenidentified.ThisprocedureallowsFDAmicrobiologiststooptimiz
16、etherecoveryofallpotentialpathogensandtoquantitateandspeciateallrecoveredorganisms.AnotherimportantaspectofproceduresusedbyFDAanalystsistodeterminegrowthpromotioncharacteristicsforallofthemediaused.Theselectionoftheappropriateneutralizingagentsarelargelydependentuponthepreservativeandformulationofth
17、eproductunderevaluation.Ifthereisgrowthintheenrichmentbroth,transfertomoreselectiveagarmediaorsuitableenrichmentagarmaybenecessaryforsubsequentidentification.MicrobiologicaltestingmayincludeanidentificationofcoloniesfoundduringtheTotalAerobicPlateCounttest.Again,theidentificationshouldnotmerelybelim
18、itedtotheUSPindicatororganisms.TheimportanceofidentifyingallisolatesfromeitherorbothTotalPlateCounttestingandenrichmenttestingwilldependupontheproductanditsintendeduse.Obviously,ifanoralsoliddosageformsuchasatabletistested,itmaybeacceptabletoidentifyisolateswhentestingshowshighlevels.However,forothe
19、rproductssuchastopicals,inhalantsornasalsolutionswherethereisamajorconcernformicrobiologicalcontamination,isolatesfromplatecounts,aswellasenrichmenttesting,shouldbeidentified.III.FACILITIES,EQUIPMENT,ANDMEDIABegintheinspectionwithareviewofanalysesbeingconductedandinspecttheplatesandtubesofmediabeing
20、incubated(cautionshouldbeexercisednottoinadvertentlycontaminateplatesortubesofmediaontest).Beparticularlyalertforreteststhathavenotbeendocumentedand“specialprojects”inwhichinvestigationsofcontaminationproblemshavebeenidentified.Thiscanbeevaluatedbyreviewingtheongoinganalyses(productorenvironmental)f
21、orpositivetestresults.Requesttoreviewthepreviousdaysplatesandmedia,ifavailableandcompareyourobservationstotherecordedentriesinthelogs.Inspecttheautoclavesusedforthesterilizationofmedia.Autoclavesmaylacktheabilitytodisplacesteamwithsterilefilteredair.Forsealedbottlesofmedia,thiswouldnotpresentaproble
22、m.However,fornon-sealedbottlesorflasksofmedia,non-sterileairhasledtothecontaminationofmedia.Inaddition,autoclavinglessthantherequiredtimewillalsoallowmediaassociatedcontaminantstogrowandcauseafalsepositiveresult.Theseproblemsmaybemoreprevalentinlaboratorieswithaheavyworkload.Checkthetemperatureofthe
23、autoclavesinceoverheatingcandenatureandevencharnecessarynutrients.Thisallowsforalessthanoptimalrecoveryofalreadystressedmicroorganisms.Theobviousproblemwithpotentialfalsepositivesistheinabilitytodifferentiatebetweeninadvertentmediumcontaminationandtruecontaminationdirectlyassociatedwiththesampletest
24、ed.IV.STERILITYTESTINGOn10/11/91,theAgencypublishedaproposedruleregardingthemanufactureofdrugproductsbyasepticprocessingandterminalsterilization.Alistofcontaminatedorpotentiallycontaminateddrugproductsmadebyasepticprocessingandlaterrecalledwasalsomadeavailable.Manyoftheinvestigations/inspectionsofth
25、erecalledproductsstartedwithalistofinitialsterilitytestfailures.FDAreviewofthemanufacturersproduction,controls,investigationsandtheirinadequacies,coupledwiththeevidenceofproductfailure(initialsterilitytestfailure)ultimatelyledtotheaction.TheUSPpointsoutthatthefacilitiesusedtoconductsterilitytestssho
26、uldbesimilartothoseusedformanufacturingproduct.TheUSPstates,Thefacilityforsterilitytestingshouldbesuchastooffernogreateramicrobialchallengetothearticlesbeingtestedthanthatofanasepticprocessingproductionfacility.Properdesignwould,therefore,includeagowningareaandpass-throughairlock.Environmentalmonito
27、ringandgowningshouldbeequivalenttothatusedformanufacturingproduct.Sinceanumberofproductandmediamanipulationsareinvolvedinconductingasterilitytest,itisrecommendedthattheinspectionincludeactualobservationofthesterilitytesteventhoughsomecompanieshavetriedtodiscourageinspectiononthegroundsthatitmaymaket
28、hefirmsanalystnervous.Theinspectionteamisexpectedtobesensitivetothisconcernandmaketheobservationsinamannerthatwillcreatetheleastamountofdisruptioninthenormaloperatingenvironment.Nevertheless,suchconcernsarenotsufficientcauseforyoutosuspendthisportionoftheinspection.Oneofthemostimportantaspectsofthei
29、nspectionofasterilityanalyticalprogramistoreviewrecordsofinitialpositivesterilitytestresults.Requestlistsoftestfailurestofacilitatereviewofproductionandcontrolrecordsandinvestigationreports.Particularly,forthehighriskasepticallyfilledproduct,initialpositivesterilitytestresultsandinvestigationsshould
30、bereviewed.Itisdifficultforthemanufacturertojustifythereleaseofaproductfilledasepticallythatfailsaninitialsterilitytestwithoutidentifyingspecificproblemsassociatedwiththecontrolsusedforthesterilitytest.Examinetheuseofnegativecontrols.Theyareparticularlyimportanttoahighqualitysterilitytest.Goodpracti
31、ceforsuchtestingincludestheuseofknownterminallysterilizedorirradiatedsamplesasasystemcontrol.Alternatively,vialsorampulesfilledduringmediafillshavealsobeenused.Beespeciallyconcernedaboutthecasewhereamanufacturerofasepticallyfilledproductshasneverfoundaninitialpositivesterilitytest.Whilesuchsituation
32、smayoccur,theyarerare.Inonecase,amanufacturersrecordsshowedthattheyhadneverfoundapositiveresult;theirrecordshadbeenfalsified.Also,theabsenceofinitialpositivesmayindicatethatthetesthasnotbeenvalidatedtodemonstratethatthereisnocarryoverofinhibitionfromtheproductorpreservative.Inspectroboticsystemsoris
33、olationtechnology,suchasLaCalheneunitsusedforsterilitytesting.Theseunitsallowproductwithdrawalintheabsenceofpeople.Ifaninitialtestfailureisnotedinasampletestedinsuchasystem,itcouldbeverydifficulttojustifyreleasebasedonaretest,particularlyiftestcontrolsarenegative.Evaluatethetimeperiodusedforsterilit
34、ytestsampleincubation.Thisissuehasbeenrecentlyclarified.TheUSPstatesthatsamplesaretobeincubatedforatleast7days,andaproposalhasbeenmadetochangetheUSPtorequireaperiodof14daysincubation.Youareexpectedtoevaluatethespecificanalyticalprocedureandtheproductfortheproperincubationperiod.Sevendaysmaybeinsuffi
35、cient,particularlywhenslowgrowingorganismshavebeenidentified.Mediafill,environmental,sterilitytestresultsandotherdatashouldbereviewedtoassuretheabsenceofslowgrowingorganisms.Also,youshouldcomparethemethodsbeingusedforincubationtodetermineiftheyconformtothoselistedinapprovedorpendingapplications.V.ME
36、THODOLOGYANDVALIDATIONOFTESTPROCEDURESDeterminethesourceoftestprocedures.Manufacturersderivetestproceduresfromseveralsources,includingtheUSP,BAMandothermicrobiologicalreferences.Itwouldbevirtuallyimpossibletocompletelyvalidatetestproceduresforeveryorganismthatmaybeobjectionable.However,itisagoodprac
37、ticetoassurethatinhibitorysubstancesinsamplesareneutralized.Duringinspections,includingpre-approvalinspections,evaluatethemethodologyformicrobiologicaltesting.Forexample,weexpecttestmethodstoidentifythepresenceoforganismssuchasPseudomonascepaciaorotherPseudomonasspeciesthatmaybeobjectionalorpresenta
38、hazardtotheuser.Wherepre-approvalinspectionsarebeingconducted,comparethemethodbeingusedagainsttheonesubmittedintheapplication.Alsoverifythatthelaboratoryhastheequipmentnecessarytoperformthetestsandthattheequipmentwasavailableandingoodoperatingconditiononthedatesofcriticaltesting.TheUSPstatesthatanal
39、ternatemethodmaybesubstitutedforcompendialtests,providedithasbeenproperlyvalidatedasgivingequivalentorbetterresults.Youmayfindthatdehydratedmediaarebeingusedforthepreparationofmedia.Goodpracticeincludestheperiodicchallengeofpreparedmediawithlowlevelsoforganisms.ThisincludesUSPindicatororganismsaswel
40、lasnormalflora.Thecapabilityofthemediatopromotethegrowthoforganismsmaybeaffectedbythemediapreparationprocess,sterilization(overheating)andstorage.Theserepresentimportantconsiderationsinanyinspectionandinthegoodmanagementofamicrobiologylaboratory.VI.DATASTORAGEEvaluatethetestresultsthathavebeenentere
41、dineitherlogbooksoronlooseanalyticalsheets.Whilesomemanufacturersmaybereluctanttoprovidetabulations,summaries,orprintoutsofmicrobiologicaltestresults,thisdatashouldbereviewedfortheidentificationofpotentialmicrobialproblemsinprocessing.Whensummariesofthisdataarenotavailabletheinspectionteamisexpected
42、toreviewenoughdatatoconstructtheirownsummaryofthelaboratorytestresultsandqualitycontrolprogram.Somelaboratoriesutilizepreprintedformsonlyforrecordingtestdata.Somelaboratorieshavealsopointedoutthattheonlywaymicrobiologicaltestdatacouldbereviewedduringinspectionswouldbetoreviewindividualbatchrecords.H
43、owever,inmostcases,preprintedformsareinmultiplecopieswithasecondorthirdcopyinacentralfile.Somecompaniesuselog-booksforrecordingdata.Theselogbooksshouldalsobereviewed.Additionally,manymanufacturersareequippedwithanautomatedmicrobialsystemfortheidentificationofmicroorganisms.Logsofsuchtesting,alongwit
44、htheidentificationofthesourceofthesample,arealsoofvalueintheidentificationofpotentialmicrobialproblemsinprocessing.Theutilizationofautomatedsystemsfortheidentificationofmicroorganismsisrelativelycommonintheparenteralmanufacturerwhereisolatesfromtheenvironment,watersystems,validationandpeoplearerouti
45、nelyidentified.MicrobiologistsinourBaltimoreDistrictareexpertontheuseofautomatedmicrobicanalyticalsystems.TheywerethefirstFDAlaboratorytousesuchequipmentandhaveconsiderableexperienceinvalidatingmethodsforthesepiecesofequipment.ContacttheBaltimoreDistrictlaboratoryforinformationorquestionsabouttheses
46、ystems.PlantswithheavyutilizationofthesepiecesofequipmentshouldbeinspectedbyindividualsfromtheBaltimoreDistrictlaboratory.VII.MANAGEMENTREVIEWMicrobiologicaltestresultsrepresentoneofthemoredifficultareasfortheevaluationandinterpretationofdata.Theseevaluationsrequireextensivetrainingandexperienceinmi
47、crobiology.Understandingthemethodology,andmoreimportantly,understandingthelimitationsofthetestpresentthemoredifficultissues.Forexample,amanufacturerfoundhighcountsofEnterobactercloacaeintheiroraldosageformproductderivedfromanaturalsubstance.SincetheydidnotisolateE.coli,theyreleasedtheproduct.FDAanalysisfoundE.cloacaeinmostsamplesfromthebatchandevenE.coliinonesample.Inthiscasemanagementfailedtorecognizethatmicrobiologicalcontaminationmightnotbeuniform,thatotherorganismsmaymaskthepresenceofcertainorganismswhenidentificationproceduresareperformed,andthatmicrobiologicaltestingisfarfroma
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 智慧農(nóng)業(yè)技術(shù)推廣實(shí)戰(zhàn)手冊(cè)
- 浙江廣告字施工方案
- 2025年人力資源制度:人事勞動(dòng)合同管理程序
- 定向井技術(shù)服務(wù)合同
- 設(shè)計(jì)和施工方案資質(zhì)
- 防彈玻璃施工方案
- 戶(hù)內(nèi)沉箱滲水施工方案
- TACCEM 129-2024 糧食環(huán)鏈刮板輸送機(jī)
- 鐵路伸縮縫圖片施工方案
- 威海鋁鎂錳屋面施工方案
- 2025年渭南職業(yè)技術(shù)學(xué)院?jiǎn)握新殬I(yè)技能測(cè)試題庫(kù)及答案一套
- 2025年貴州貴安新區(qū)產(chǎn)業(yè)發(fā)展控股集團(tuán)有限公司招聘筆試參考題庫(kù)附帶答案詳解
- 機(jī)械制造技術(shù)基礎(chǔ)(課程課件完整版)
- 煤礦崗位標(biāo)準(zhǔn)化作業(yè)流程
- 電子病歷及病歷信息標(biāo)準(zhǔn)化(第五講)
- 鐵路建設(shè)項(xiàng)目工程試驗(yàn)室管理標(biāo)準(zhǔn)TB104422009
- SPSS術(shù)語(yǔ)中英文對(duì)照詳解
- 第六章、光致抗蝕劑PPT課件
- 正泰電器低壓電器選型手冊(cè)
- 室內(nèi)電氣施工設(shè)計(jì)說(shuō)明
- 各種中西藥特效外敷方藥
評(píng)論
0/150
提交評(píng)論