健康樹木可持續(xù)發(fā)展性_第1頁(yè)
健康樹木可持續(xù)發(fā)展性_第2頁(yè)
健康樹木可持續(xù)發(fā)展性_第3頁(yè)
健康樹木可持續(xù)發(fā)展性_第4頁(yè)
健康樹木可持續(xù)發(fā)展性_第5頁(yè)
已閱讀5頁(yè),還剩45頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

健康樹木可持續(xù)發(fā)展性IntroductionAboutTCOTAboutmeAboutHealthyTreesAboutyouInfrastructureRenovationsfor23rdStreetMedianCrystalCity,VASessionOverviewWheredoHealthTreesbegin?GettingtotheRootoftheProblemDesignforSustainabilityNewTechniquesforSuccessinHealthyTreesQ&A“Ifsomedaywearetoknoweverythingthereistoknowabouttheabovegroundportionofthetree,wewillstillonlyknow…”

Dr.AlexShigoUSForestService“…h(huán)alfthestory!”HealthyTreesstartwithHealthyRoots-“MythBusters”Dotreeroots

reallyextendonly

tothedrip-lines?Whatabouttaproots,mirrorimages,&formulas…?“FirstAnnualNationalCapitolRootAppreciationDay”RockSpringPark,Bethesda,MD-November199215”HoneyLocust:rootradius=34feetAnotherrootmythdebunkedMythBusters4thAnnualNationalCapitolRootAppreciationDayManassasParkHighSchoolManassas,VA

Whydidweneednewmethods?

Howdowefindthem?

AndwhatdidtheCEOnotaskfor…?BaltimoreLifeHomeOffice,OwingsMills,MD1992and2008HealthyTreesinconstructioncomefromteamworkandbeginattheDesignTable

WhodoyouinvitetoyourTable?SustainableDesignvsDesignAfterthoughtsSupersonicAir-ToolsGeo-compositesforHealthyRootHealthySoilBiologyUSSenateParkPerimeterSecurityConceptualDesign/BuildTeamHowdoweusetreesasDesignElements?Oraretheymere“Afterthoughts”?Ifthetreesareadesignelement,notanafter-thought,thenyouhaveSustainableinyourDesign.5yearslater…“AreweSustainableyet?”“Wherearetheroots?”

Mach2SupersonicAir-tool(SSAT)forRootInvestigationQuestionfortheprofessors:“HowfastisMACH2?”RootInvestigationforSenateParkPerimeterSecurityDesignDocumentfindingsandpreparerecommendationsfordesignmodification.NorthernRedOak“Kwanza”FloweringCherryProposedUSCapitolSecurityBollards

Assessimpactanddeterminealternatedesign&constructionproceduresRootInvestigativeStudyReport

Objectives:DeterminegrowthcharacteristicsofrepresentativetreespeciesinLoudounCounty,VAbymeansofinvestigativedigginginrepresentativespecies,soilsandhydrologicalregime.TheresultsofthisStudyareusedtodeterminestrategiesindesignandconstructionaswellasprescribeappropriateprotectionmeasures&stressreductiontherapies.

BeginningSupersonicAirtool(SSAT)Investigationwithinproposedroadwayselectingrepresentativetreespecies:

WhiteOak,RedOak,Hickory,Ash.

Noterootsareverynearsurface.ThisisnotcharacteristicofwhiteoaksinMontgomeryCountyMDPiedmontinloamyclaymicarichsoils.Deeperrestrictivelayersareassumedtobethereason.Refertosoilsboringreportsforverification.TechnicalFindings23”WHITEOAK(whitepaintforphoto)TOTALROOTLENGTH(est.)=50’DIAM.ATDIST.FROMTRUNK3”@10’1”@20’.5-.75”@30’.25-.5”@40’ENDATEST50’ConceptDesignforProposedCorporateFinancialCenterNationalRuralUtilities,DullesTownCenter,VASeverallocationsatthePennsylvaniaStateCapitolSouthParkwereidentifiedwithtreeswhicharehavingpotentialdesignelementsinstalledorrenovatedwithintheirCriticalRootZones(CRZs)withpotentialformajorimpacts.Thesedesignelementsarestormdrainpipeandinfiltrationbeds,concretesteps,electricsitelightconduits,retainingwalls,waterlines,andwalkdemolitionandreconstruction.

RenovationstoPennsylvaniaStateCapitolSouthParkLandscapeConstructionSuperintendentdocumentingsignificantrootdepthandlocationfordesignofgradebeam.RenovationsofprivateresidenceinPhiladelphia,PAUtilizeSSATforloweringgradewithinCRZsfornewsidewalkRootInvestigationduringdemolitiontodetermineneedforspecialdesignmodificationsforretaining38”Quercusphellos.IndependenceAvenueStreetscapeRenovationatthe

USCapitolHouseOfficeBuildingaka“LongworthOak”5yearslater….WorkinginsidethecriticalrootzonewithSSATInserting$3,000lightpolebasebetween2matureQuercusphellosatthehistoricHomewoodHouseJohnsHopkinsUniversityHomewoodCampusBaltimore,MDLandscapeRenovationsDesign/BuildSprinklerandlowvoltageelectricalcableinstallation“Butweareonlydigginglessthanafootdeep!”Architects:Crossout“Shallbehandexcavated”inyourMasterSpec!RootPruningwithSSAT/HandToolsforroots>1.5”diameterorwithininner?ofCRZradius.MethodofRootPruningtobedetermined….PerimeterSecurityforLafayettePark,PennsylvaniaAve&15thStreet,Wash.DC“SmithsonianLevel”RootPruning

attheHauptGarden,WashingtonDC

UtilizingtheSuperSonicShopVac(SSSV)Problem:SustainingHealthyTreesonaCampusorCommercialSitewithpoorsoilsorpedestriancompactionovertime.Nativehealthytopsoils=80%compaction;Urbansiteseasily90%-98%.Howcanyou“decompact”soilswithoutrootdamage?SSATtotherescue!RadialMulchingwithSSATto“De-compact”SoilsBackfillwith50%OrganicCompostExcellenttimeforCompost Teas/HumatesStandBack!ShadyGroveAdventistHospitalRenovations,Gaithersburg,MDSubsurfacebasal

decaycanbeverified

aswellas“Girdlingroot”

investigationcanbe

doneatsametimeSustainingtreesingradefillsinsitedesign48”DBHHickory

WheretoputPhaseIto

PhaseIIconnectingdrive?T.RowePriceFinancialCenterOwingsMills,MD1995GradefillsproposedwithintheCRZrequirespecialdesignmodificationandspecialconstructionprocedures“Rootfriendly”pavementsectionemployingthelatestingroundengagingtechnologiesSustainingTreesingradefillsinsitedesignButdoesitwork?10yearslater…“AreweSustainableyet?”RootAerationSystemsfrom1983-1993BaltimoreLifeInsuranceHomeOffice,OwingsMillsCorporatePark,MD199315yearslater…AndwhatquestiondidtheCEOnotask…?LatestRootAerationMat(RAM)from1996-2008SpecialtyTriplePlyGeocompositeFlexible,easeofinstallation,lessexpensiveCAUTION:ExperiencedGeotechnicalSpecialistprescribedforeachsoils&loadingpotential.Specification,layout,installation,onlyunderdirectionofCertifiedArborist/Foresterexperiencedinrootengagingtechnologies.RootAerationSystemDesignGuidelineforPreservingTreesinConstructionGradeFillsThishandoutwasdesignedtoassistsitedesignprofessionalsoragencyreviewingstaffwithbasicunderstandingofobjectives,limitations,andparameterstoconsiderintreepreservationdealingwithissuesofproposedgradefills.ThepurposeoftheRootAerationMat(RAM)istwo-fold:first,toprovidenecessaryair/gasexchangebetweentheatmosphereandthecriticalrootzonethatwillbecoveredbyaproposedgradefillsituation;andsecond,tospreadthisloadingandprovideastablebaseinconjunctionwithotherengineeredmaterialstosupporttheproposedstructuralornonstructuralfills.Rootsoftreesforthemostpartrequireporoussoilsof80%compactionasfoundinforestsoils.Evenfillsofafewinchesovertheexistinggradeofrootscanbringaboutsuffocationandtoxicbuildupinashorttime.RootAerationSystemshavebeenemployedsuccessfullyformanyyearsinawidevarietyofconstructionscenarios,includingretainingwalls,parkinglots,statehighways,andtoeofslopeconditions.Eachsiteandapplicationvariesthusmaterialsanddesignwillvary.TheCareofTrees,Inc.Forestersfamiliarwithtreerootstructureandfunctioninginrelationtospecies,soils,andmoistureregimeimpactedbyconstructionsituationswillreviewthedesignscenarioandsite,prescribespecifications,layoutandsuperviseinstallation.Ourlatestmethodsandmaterialsarebeyondthosefoundinstateorlocalmanuals.Caution:Onlylicensedprofessionalswithmuchexperienceinrootsysteminvestigationsandimpactfromdesignandconstructionimpactsshouldattempttospecifyandprescriberootengagingtechnologies.Tomeetstructuralconcernsanexperiencedgeotechnicalprofessionalshouldbeengagedinproductandmaterialsselectionsunderproposedpavingorcurbs.

Thefollowingarestepbystepguidelinesthatapplytoawidevarietyofsituations:1.TheProjectForesterorISACertifiedArboristwilldeterminethehealthandconditionoftreesinconsideration.

Willthetreewithstandaddedconstructionstress?Aretheyworthyofconsiderationforspecialpreservationmeasures?Whatispastmaintenancehistoryorpriorimpactsfromsitedevelopment?2.Baseduponaccuratetreesurveylocationincludinggradesatbaseoftree,determinetheappropriateCriticalRootZoneforthetree(s.

Investigativediggingmaybeneededsincerootsvaryinwidthanddepthwithspecies,soiltype,moisturelevel,andurbaninfrastructureinvolved.(RefertoCRZHandoutsheets)3.ProjectForesterwillreviewgradingandutilityplanswiththeappropriatedesignteam.

HowandwherewillcutandfillimpacttheCRZ?HowwillproposedutilitiesimpactCRZ?Arethereoptionsforutilityplacement?

4.DeterminehowmanysquarefeetofRootAerationMatareneeded?5.Nosoilshouldevercontactthatpartofthetreenormallyaboveground.

Howissoiltobekeptfromthetrunkorrootflare?Ifaretainingwallisneededwhatdesignandmaterialwillfitthetreerootsystembasedupontheinvestigativedig?6.Theprojectforesterwilldesigntheappropriateventingsystemtofitthesiteandobjectives.

HowwilltheRAMbeventedtoatmosphericconditionsfortheair/gasexchangetothesoilsurface?Willaretainingwall,curb,ortoeofslopebeused?7.Forinstallationunderstructuralfillsthereviewofageotechnicalprofessionalisrequired.Wewillnotinstallstructuralsystemsunlessageotechnicalhasreviewedandapproved.Ifnoneareavailablethatarefamiliarwiththissystemwecanprovidegeotechnicalanalysisandanswerdesignloadingquestions.

8.Forstructuralfillstypically24”isminimumneededbetweenexistinggradeandproposedfinishgradeofpavement.

Geogridsandotherstabilizationmethodscanbeprescribedwhenlessthan24”isavailable.9.Resolveadditionalpertinentdesign/constructionissues:10.Whatwillbetheappropriatesequenceofeventstofacilitateconstructionbutnotcompromiseprotectionofthetreerootsystem? b.Willtheest.impacttothetreesrequirerelatedtreeprotectionitemssuchasrootpruningandsilt/treeprotectionfence?Howwillthosebesequenced? c.Willadditionalarboriculturespecificationsbeprescribedfortheimpactedtrees?Thesemayincludemulching;fertilization/soilconditioners;;crownpruning;cabling/lightningprotection;andIPMneeds. d.Howwillselectiveremovalofsaplings,brush,andvineswithintheprotectedCRZbeprescribed?11.AllworkwithintheCRZshallbelaidoutbytheprojectforesterorarboristandreviewedbythelandscapearchitect/civilandsitesuperintendent.InstallationshouldalwaysbebyISACertifiedArboristwithexperienceinthistypeofwork.Budgetnumberfortherootaerationmatsystemsisusuallybetween$2.00-3.00/squarefootinstalleddependingupondegreeofdifficultyandeconomiesofscale.Forasite/treeassessmentandplanreviewcontactoneofourlocaloffices.Foranin-officeeducationalpowerpointpresentationregardingtheseandotherstateofthearetreepreservationplanning,design,orconstructionmeasures,callthebelowoffice. TheCareofTrees,Inc.,theleaderin“rootengagingtechnologies”.SustainingRoots-DesignGuidelineforPreservingTreesinConstructionGradeFillsThepurposeoftheRootAerationMat(RAM)istwo-fold:1)Provideatmosphericgasexchange,2)Stabilizeandspreadtheload.RootsoftreesforthemostpartrequireporoussoilsNosoilshouldevercontactthatpart

ofthetreenormallyabovegroundTheprojectforesterwilldesigntheappropriate

ventingsystemtofitthesiteandobjectivesForinstallationunderstructuralfillsthereview

ofageotechnicalprofessionalisrequiredForstructuralfillstypically24”isminimumneededbetween

existinggradeandproposedfinishgradeofpavementResolveadditionalpertinentdesign/constructionissuesAllworkwithintheCRZshallbelaidoutbytheprojectforester

orarboristandreviewedbythelandscapearchitect/civiland

sitesuperintendentHowdowesustainrootsadjacenttobuildingexcavationsbutstillallowroomtobuild?

HealthyRootsattheedge-AsolutiontotheinterfaceofSuperSiltFenceLOD/TPFthatavoidscuttingrootsforSSFHowdowebuildamasonrystructure

between2prizedmaturetrees?IncorporateRootProtectionMatting(RPM)intothedesignandconstructionPrivateresidenceonHillmeadRd,Bethesda,MD.RootProtectionMatSpecificationsRootProtectionMatwithinCRZs(asdesignatedonTPAK):ObjectiveofRPMistoallowdesignatedconstructionactivitieswithinthetreesprotectedcriticalrootzonewithminimalcompactionorruttingtosurfacesoilsandrootsystem.MethodsandproceduresfordemolitionofRPMisjustascriticalastheproperinstallation.RPMspecificationsarealwaysafunctionofparentsoilmake-upandprojectedloading(staticVSdynamiccompaction)andfrequency/numberoftrips.Soilmake-upcanvarywithseasons(wetvsdry).Experiencedgeotechnicalrepresentativeshouldbeconsultedonceexactloadingpotentialisknown.Exactlocation/layoutofRPMtobeapprovedbyprojectforester.Storm&SanitarySewerExcavationwithsteeltrackedexcavator:-2layersRPMoverwoodchipswithAlturnamatWaterlineorconduitexcavationusingrubbertrackedmini-excavatorwithpsi4.2orlesswithoperatorandload):-2"mulch+TriplanerGeonet(doublesided)forequipmentoperationandsoilsstockpilewithinCRZofprotectedtrees.TemporaryMobileHome/ConstructionTrailerwithnovehicleparking--sameasabove.UseRubbertrackedskidsteerforinstallation.AllaccesswithinCRZsonRPM.Staging/StockpileAreaforheavyequipment/truckswithinCRZs--AmerdrainSoilDrainageMat+TriplanarGeonet+Bi-axilGeogrid+12"Crushedstonewithsiltfence(installedon-grade)perimeter.AboveStaging/StockpileoutsideCRZsuseonlyGeonetwithcrushedstone.AddGeogridifconcretetrucksorconstructionforkliftsareusedrepeatedly.RecommendinstallationonlybycontractarboristexperiencedinRootProtectionMattingf

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論