版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
數(shù)據(jù)中心基礎(chǔ)設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)目次1總則...........................................................................................................................22術(shù)語...........................................................................................................................33基本規(guī)定...................................................................................................................43.1運(yùn)行維護(hù)范圍.....................................................................................................43.2運(yùn)行維護(hù)基本要求.............................................................................................44運(yùn)行...........................................................................................................................54.1一般規(guī)定.............................................................................................................54.2電氣系統(tǒng).............................................................................................................54.3通風(fēng)空調(diào)系統(tǒng)...................................................................................................104.4消防系統(tǒng)...........................................................................................................114.5智能化系統(tǒng).......................................................................................................124.6環(huán)境參數(shù)...........................................................................................................135維護(hù).........................................................................................................................145.1一般規(guī)定...........................................................................................................145.2電氣系統(tǒng)...........................................................................................................145.3通風(fēng)空調(diào)系統(tǒng)...................................................................................................175.4消防系統(tǒng)...........................................................................................................205.5智能化系統(tǒng).......................................................................................................216制度.........................................................................................................................236.1一般規(guī)定...........................................................................................................236.2制度體系...........................................................................................................23本標(biāo)準(zhǔn)用詞說明.........................................................................................................24引用標(biāo)準(zhǔn)名錄.............................................................................................................2511總則1.0.1為實(shí)現(xiàn)數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備運(yùn)行維護(hù)的規(guī)范性、安全性和及時(shí)性,確保電子信息設(shè)備運(yùn)行環(huán)境的穩(wěn)定可靠,制訂本標(biāo)準(zhǔn)。1.0.2本標(biāo)準(zhǔn)適用于已投入運(yùn)行的數(shù)據(jù)中心。1.0.3數(shù)據(jù)中心基礎(chǔ)設(shè)施的運(yùn)行維護(hù)除應(yīng)符合本標(biāo)準(zhǔn)外,尚應(yīng)符合國家現(xiàn)行有關(guān)標(biāo)準(zhǔn)的規(guī)定。22術(shù)語2.0.1數(shù)據(jù)中心datacenter為集中放置的電子信息設(shè)備提供運(yùn)行環(huán)境的建筑場所,可以是一棟或幾棟建筑物,也可以是一棟建筑物的一部分,包括主機(jī)房、輔助區(qū)、支持區(qū)和行政管理區(qū)等。2.0.2基礎(chǔ)設(shè)施infrastructure數(shù)據(jù)中心內(nèi),為電子信息設(shè)備提供運(yùn)行保障的設(shè)施。2.0.3運(yùn)行operation對(duì)數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備進(jìn)行日常巡檢、啟??刂?、參數(shù)設(shè)置、狀態(tài)監(jiān)控和優(yōu)化調(diào)節(jié)。2.0.4維護(hù)maintenance為保證數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備具備良好的運(yùn)行工況,達(dá)到提高可靠性、排除隱患、延長壽命期目的所進(jìn)行的工作,主要包括預(yù)防性維護(hù)、預(yù)測性維護(hù)和維修等。2.0.5預(yù)防性維護(hù)preventivemaintenance為降低數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備發(fā)生失效或功能退化的概率,按預(yù)定的時(shí)間間隔或按既定的準(zhǔn)則實(shí)施的維護(hù)。2.0.6預(yù)測性維護(hù)predictivemaintenance通過各種技術(shù)手段進(jìn)行數(shù)據(jù)和信號(hào)的采集、分析,同時(shí)結(jié)合設(shè)備運(yùn)行的壽命期統(tǒng)計(jì)規(guī)律或歷史數(shù)據(jù),預(yù)測可能后果,提前采取的有針對(duì)性的維護(hù)活動(dòng)。2.0.7事件incident是指意外發(fā)生的導(dǎo)致或可能導(dǎo)致服務(wù)中斷或服務(wù)質(zhì)量下降的事態(tài)。2.0.8變更c(diǎn)hange是指在運(yùn)行和維護(hù)過程中對(duì)數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備所做的各種改變,包括狀態(tài)改變、增補(bǔ)、移除和其他變動(dòng)。33基本規(guī)定3.1運(yùn)行維護(hù)范圍數(shù)據(jù)中心基礎(chǔ)設(shè)施運(yùn)行維護(hù)范圍應(yīng)包括下列系統(tǒng):電氣系統(tǒng)、通風(fēng)空調(diào)系統(tǒng)、消防系統(tǒng)、智能化系統(tǒng)。電氣系統(tǒng)的運(yùn)行維護(hù)范圍應(yīng)包括:供配電系統(tǒng)、不間斷電源和后備電源系統(tǒng)、照明系統(tǒng)、配電線路布線系統(tǒng)、防雷與接地系統(tǒng)。通風(fēng)空調(diào)系統(tǒng)的運(yùn)行維護(hù)范圍應(yīng)包括:冷源和水系統(tǒng)、機(jī)房空調(diào)和風(fēng)系統(tǒng)。消防系統(tǒng)的運(yùn)行維護(hù)范圍應(yīng)包括:火災(zāi)自動(dòng)報(bào)警系統(tǒng)、消防聯(lián)動(dòng)系統(tǒng)、自動(dòng)滅火系統(tǒng)。智能化系統(tǒng)的運(yùn)行維護(hù)范圍應(yīng)包括:環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)。3.2運(yùn)行維護(hù)基本要求運(yùn)行維護(hù)團(tuán)隊(duì)宜參與基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備安裝、調(diào)試和驗(yàn)證的過程。數(shù)據(jù)中心正式投入使用前應(yīng)進(jìn)行綜合系統(tǒng)測試。數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備的運(yùn)行維護(hù)管理應(yīng)實(shí)現(xiàn)如下基本目標(biāo):1通過有效地計(jì)劃、組織、協(xié)調(diào)與控制,確保電子信息設(shè)備運(yùn)行環(huán)境穩(wěn)定可靠。2通過科學(xué)管理,實(shí)現(xiàn)數(shù)據(jù)中心基礎(chǔ)設(shè)施運(yùn)行維護(hù)服務(wù)與經(jīng)濟(jì)性的最優(yōu)化。數(shù)據(jù)中心基礎(chǔ)設(shè)施的運(yùn)行維護(hù)宜按不同設(shè)計(jì)或建設(shè)等級(jí)進(jìn)行。數(shù)據(jù)中心場地周邊的地質(zhì)災(zāi)害、水災(zāi)、火災(zāi)等隱患應(yīng)定期進(jìn)行檢查。電力、制冷和消防等各系統(tǒng)應(yīng)定期進(jìn)行聯(lián)動(dòng)測試。運(yùn)行維護(hù)人員發(fā)現(xiàn)基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備隱患、異常、故障、報(bào)警等問題,應(yīng)按照事件管理程序或既定處理措施處理?;A(chǔ)設(shè)施系統(tǒng)與設(shè)備故障和維護(hù)期間,應(yīng)有相應(yīng)的保障措施和應(yīng)急預(yù)案。數(shù)據(jù)中心運(yùn)行維護(hù)操作人員應(yīng)具備行業(yè)規(guī)定的職業(yè)資格。44運(yùn)行4.1一般規(guī)定基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備運(yùn)行應(yīng)包括值班、監(jiān)控、日常巡檢、運(yùn)行操作、報(bào)警和事件處理等內(nèi)容。A級(jí)數(shù)據(jù)中心應(yīng)24小時(shí)值班,B級(jí)和C級(jí)數(shù)據(jù)中心宜按照電子信息設(shè)備負(fù)載的重要性確定值班時(shí)間。消防系統(tǒng)和安全防范系統(tǒng)應(yīng)24小時(shí)保持正常工作狀態(tài),不得隨意中斷。運(yùn)行人員應(yīng)按照巡檢計(jì)劃、周期、規(guī)定路線對(duì)基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備及運(yùn)行環(huán)境進(jìn)行巡檢,巡檢記錄應(yīng)及時(shí)、完整、真實(shí)、清晰。A級(jí)數(shù)據(jù)中心每日現(xiàn)場巡檢次數(shù)不應(yīng)少于2次,B級(jí)和C級(jí)數(shù)據(jù)中心每日現(xiàn)場巡檢次數(shù)不應(yīng)少于1次。有能耗計(jì)量系統(tǒng)的數(shù)據(jù)中心,應(yīng)保證能耗計(jì)量裝置正常工作,數(shù)據(jù)完整有效。數(shù)據(jù)中心能耗數(shù)據(jù)應(yīng)定期進(jìn)行綜合分析,合理優(yōu)化電氣與通風(fēng)空調(diào)系統(tǒng)的運(yùn)行控制策略,提高整體電能使用效率。設(shè)備有備用或冗余的,應(yīng)輪換使用。4.2電氣系統(tǒng)I供配電系統(tǒng)高壓供配電設(shè)備應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控和報(bào)警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.1-1所列內(nèi)容,報(bào)警不應(yīng)少于表4.2.12所列內(nèi)容。表11234表212534高壓配電室或值班室內(nèi)應(yīng)設(shè)置數(shù)據(jù)中心供配電系統(tǒng)圖。主機(jī)房和非主機(jī)房使用的供配電設(shè)備應(yīng)有明確的標(biāo)識(shí)并宜進(jìn)行顏色區(qū)分。高壓供配電設(shè)備日常巡檢不應(yīng)少于表4.2.4所列內(nèi)容。表1性23456變壓器應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控和報(bào)警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.51所列內(nèi)容,報(bào)警不應(yīng)少于表4.2.52所列內(nèi)容。表1123表212變壓器日常巡檢不應(yīng)少于表4.2.6所列內(nèi)容。表1234低壓配電設(shè)備和列頭柜應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控和報(bào)警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.71和4.2.72所列內(nèi)容,報(bào)警不應(yīng)少于表4.2.73和4.2.74所列內(nèi)容。表16123456表212表312345表412低壓配電設(shè)備和列頭柜日常巡檢不應(yīng)少于表4.2.81和4.2.82所列內(nèi)容。表112345表2123II不間斷電源和后備電源系統(tǒng)UPS(不間斷電源系統(tǒng))室和直流電源室溫度宜保持在20~30℃,相對(duì)濕7度應(yīng)保持在20%~80%,不得結(jié)露。UPS應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控和報(bào)警系統(tǒng),報(bào)警內(nèi)容應(yīng)包括當(dāng)前報(bào)警和歷史報(bào)警,監(jiān)控不應(yīng)少于表4.2.10所列內(nèi)容。表1234UPS日常巡檢不應(yīng)少于表4.2.11所列內(nèi)容。表1234直流電源系統(tǒng)應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控和報(bào)警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.12-1所列內(nèi)容,報(bào)警不應(yīng)少于表4.2.122所列內(nèi)容。表1123表2123直流電源日常巡檢不應(yīng)少于表4.2.13所列內(nèi)容。表12345蓄電池室溫度應(yīng)保持在20~30℃。蓄電池應(yīng)設(shè)置運(yùn)行參數(shù)監(jiān)控系統(tǒng),監(jiān)控不宜少于表4.2.15所列內(nèi)容。表812蓄電池日常巡檢不應(yīng)少于表4.2.16所列內(nèi)容。表1234柴油發(fā)電機(jī)組運(yùn)行對(duì)象應(yīng)包括發(fā)動(dòng)機(jī)、發(fā)電機(jī)、控制系統(tǒng)、電氣系統(tǒng)、冷卻系統(tǒng)、燃油系統(tǒng)、潤滑系統(tǒng)、進(jìn)排風(fēng)系統(tǒng)和排煙系統(tǒng)。柴油發(fā)電機(jī)組日常巡檢不應(yīng)少于表4.2.18所列內(nèi)容。表12345678○○○○○注:日常巡檢內(nèi)容包括柴油發(fā)電機(jī)組待機(jī)和運(yùn)轉(zhuǎn)兩種狀態(tài)下的日常巡檢內(nèi)”代表不同狀態(tài)下需要檢查內(nèi)容的選項(xiàng)標(biāo)記?!餓II照明系統(tǒng)照明運(yùn)行對(duì)象應(yīng)包括正常照明、備用照明和消防應(yīng)急照明。照明設(shè)備日常巡檢不應(yīng)少于表4.2.20所列內(nèi)容。表192344.3通風(fēng)空調(diào)系統(tǒng)I冷源和水系統(tǒng)制冷機(jī)組、冷凍水泵、冷卻水泵、冷卻塔、電控水閥應(yīng)采取群控方式,根據(jù)系統(tǒng)負(fù)荷變化和機(jī)組特性制定運(yùn)行策略。在滿足除濕和供冷需求的條件下,制冷機(jī)組供水溫度宜適當(dāng)提高。具備冷卻塔供冷措施的空調(diào)系統(tǒng)在過渡季和冬季運(yùn)行時(shí),應(yīng)根據(jù)室外氣象條件進(jìn)行自然供冷與冷機(jī)供冷模式的切換。采用變頻控制的水泵和冷卻塔風(fēng)機(jī),當(dāng)電機(jī)無獨(dú)立散熱措施時(shí),頻率不宜低于30Hz。當(dāng)室外溫度低于冰點(diǎn)時(shí),冷卻水系統(tǒng)應(yīng)采取防凍措施。冷源和水系統(tǒng)運(yùn)行監(jiān)控不應(yīng)少于表4.3.6所列內(nèi)容。表1234泵率制冷機(jī)組應(yīng)進(jìn)行日常巡檢,巡檢不應(yīng)少于表4.3.7所列內(nèi)容。表12冷卻塔應(yīng)進(jìn)行日常巡檢,巡檢內(nèi)容應(yīng)包括風(fēng)機(jī)有無異常聲響、飄水、漏水和冬季結(jié)冰情況檢查。水泵應(yīng)進(jìn)行日常巡檢,巡檢不應(yīng)少于表4.3.9所列內(nèi)容。表12103空調(diào)水系統(tǒng)的定壓設(shè)施、補(bǔ)水箱、軟化水箱、管道、閥門附件應(yīng)進(jìn)行日常巡檢,巡檢不應(yīng)少于表4.3.10所列內(nèi)容。表123II機(jī)房空調(diào)和風(fēng)系統(tǒng)室內(nèi)氣流組織應(yīng)確保合理,防止局部過熱。運(yùn)行策略應(yīng)根據(jù)氣象條件和運(yùn)行環(huán)境變化適時(shí)調(diào)整,降低局部結(jié)露風(fēng)險(xiǎn)。設(shè)置了自然冷卻措施的機(jī)房空調(diào)和風(fēng)系統(tǒng)在過渡季和冬季運(yùn)行時(shí),應(yīng)根據(jù)室外氣象條件進(jìn)行自然供冷與壓縮機(jī)供冷模式的切換。采用變頻控制的風(fēng)機(jī),應(yīng)符合本標(biāo)準(zhǔn)第4.3.4條規(guī)定。機(jī)房空調(diào)和風(fēng)系統(tǒng)監(jiān)控不應(yīng)少于表4.3.15所列內(nèi)容:表/12/停34機(jī)房空調(diào)和風(fēng)系統(tǒng)應(yīng)進(jìn)行日常巡檢,巡檢不應(yīng)少于表4.3.16所列內(nèi)容。表12空調(diào)風(fēng)系統(tǒng)管道應(yīng)進(jìn)行日常巡檢,檢查保溫層有無破損、結(jié)露。4.4消防系統(tǒng)消防控制室值班人員,應(yīng)按要求記錄消防控制室內(nèi)消防設(shè)備的運(yùn)行情況,發(fā)現(xiàn)火警或設(shè)備故障時(shí)應(yīng)立即進(jìn)行確認(rèn),并進(jìn)行相關(guān)處理,必要時(shí)應(yīng)立即啟動(dòng)相關(guān)應(yīng)急操作程序。11消防日常巡檢不應(yīng)少于表4.4.2所列內(nèi)容。表123456789數(shù)據(jù)中心區(qū)域內(nèi)的動(dòng)火作業(yè)應(yīng)經(jīng)過批準(zhǔn),并采取防護(hù)措施。動(dòng)火區(qū)域巡檢不應(yīng)少于表4.4.3所列內(nèi)容。表效1234.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)環(huán)境和設(shè)備監(jiān)控系統(tǒng)應(yīng)設(shè)置合理的控制參數(shù)設(shè)定值和聯(lián)動(dòng)控制邏輯,并在實(shí)際運(yùn)行過程中進(jìn)行優(yōu)化。對(duì)大型數(shù)據(jù)中心,可分區(qū)域進(jìn)行電能使用效率分析,并結(jié)合環(huán)境監(jiān)控?cái)?shù)據(jù)和氣流組織情況進(jìn)行優(yōu)化。II安全防范系統(tǒng)數(shù)據(jù)中心區(qū)域應(yīng)根據(jù)重要等級(jí)和功能區(qū)劃分相應(yīng)的控制區(qū)域,出入權(quán)限應(yīng)實(shí)行分區(qū)、分級(jí)管理,對(duì)重要區(qū)域可設(shè)置多重認(rèn)證措施。12各控制區(qū)域出入口宜制定視頻聯(lián)動(dòng)控制方案,并根據(jù)需要適時(shí)調(diào)整。入侵報(bào)警系統(tǒng)宜制定視頻、照明聯(lián)動(dòng)控制方案,并根據(jù)需要適時(shí)調(diào)整。入侵報(bào)警系統(tǒng)應(yīng)根據(jù)防護(hù)需要及時(shí)調(diào)整入侵探測器參數(shù)和狀態(tài)。視頻監(jiān)控系統(tǒng)應(yīng)制定使用方案,優(yōu)先顯示重點(diǎn)監(jiān)控對(duì)象。視頻監(jiān)控系統(tǒng)應(yīng)建立視頻輪巡機(jī)制,確保每路視頻信號(hào)在一定時(shí)間內(nèi)都能夠顯示在監(jiān)控屏幕上,及時(shí)發(fā)現(xiàn)視頻監(jiān)控故障。4.6環(huán)境參數(shù)主機(jī)房應(yīng)對(duì)冷通道或機(jī)柜進(jìn)風(fēng)區(qū)域的溫度和相對(duì)濕度進(jìn)行在線監(jiān)測,溫度宜保持在18~27℃,相對(duì)濕度宜保持在35%~65%。主機(jī)房運(yùn)行應(yīng)始終維持正壓,主機(jī)房與相鄰區(qū)域的壓差不宜小于1Pa。主機(jī)房壁面、設(shè)備表面結(jié)露情況應(yīng)進(jìn)行日常巡檢,若出現(xiàn)結(jié)露現(xiàn)象,應(yīng)及時(shí)采取應(yīng)對(duì)措施。主機(jī)房運(yùn)行期間宜定期檢測表4.6.4所列的環(huán)境參數(shù)。表升在和~)2主機(jī)房和輔助區(qū)的照度應(yīng)滿足運(yùn)維監(jiān)控需求。有人值守的長期固定工作位置測量的噪聲值應(yīng)小于60dB(A)。有人值守的長期固定工作位置測量的室內(nèi)空氣中CO濃度不應(yīng)大于0.1%。2人員活動(dòng)區(qū)的游離甲醛、苯、氨、氡和TVOC等空氣污染物濃度符合現(xiàn)行國家標(biāo)準(zhǔn)的相關(guān)規(guī)定。135維護(hù)5.1一般規(guī)定維護(hù)工作應(yīng)包括預(yù)防性維護(hù)、預(yù)測性維護(hù)和維修等內(nèi)容。基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備應(yīng)進(jìn)行標(biāo)識(shí),標(biāo)識(shí)應(yīng)設(shè)置于顯著位置。保修期滿的設(shè)備應(yīng)采取措施確保維護(hù)保養(yǎng)服務(wù)的連續(xù)性?;A(chǔ)設(shè)施設(shè)備周圍應(yīng)保持整潔,無雜物堆放,確保維護(hù)維修通道通暢。數(shù)據(jù)中心維護(hù)管理人員應(yīng)定期對(duì)基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備的運(yùn)行狀態(tài)進(jìn)行風(fēng)險(xiǎn)分析與評(píng)估,根據(jù)評(píng)估結(jié)果進(jìn)行預(yù)測性維護(hù)。設(shè)有內(nèi)置時(shí)鐘的設(shè)備應(yīng)定期檢查并進(jìn)行校準(zhǔn),與標(biāo)準(zhǔn)時(shí)間同步。環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)宜定期對(duì)數(shù)據(jù)進(jìn)行備份,并對(duì)備份數(shù)據(jù)進(jìn)行驗(yàn)證。5.2電氣系統(tǒng)I供配電系統(tǒng)供配電設(shè)備維護(hù)操作應(yīng)遵守一人操作、一人監(jiān)護(hù)的原則。高壓供配電設(shè)備應(yīng)按照當(dāng)?shù)毓╇姴块T要求定期進(jìn)行檢測并出具報(bào)告。高壓供配電設(shè)備宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.3所列內(nèi)容。表12345A級(jí)數(shù)據(jù)中心高壓供配電系統(tǒng)宜每半年進(jìn)行1次供電中斷應(yīng)急演練,、C級(jí)數(shù)據(jù)中心依據(jù)自身需求確定。電力變壓器宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.5所列內(nèi)容。表12314456低壓配電設(shè)備宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.6所列內(nèi)容。表12345能678關(guān)9低壓配電柜體內(nèi)電纜、母排、接線端子、斷路器應(yīng)每半年進(jìn)行1次溫度測量,并對(duì)比前次測量結(jié)果。II不間斷電源和后備電源系統(tǒng)UPS宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.8所列內(nèi)容。表123456直流電源系統(tǒng)宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.9所列內(nèi)容。表123415蓄電池宜每季度進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.10所列內(nèi)容。表123456柴油發(fā)電機(jī)組應(yīng)每月進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.2.11所列內(nèi)容。表12345柴油發(fā)電機(jī)組應(yīng)每年進(jìn)行1次帶載測試,檢查機(jī)油壓力、冷卻液溫度、轉(zhuǎn)速、電氣工作狀態(tài)、負(fù)載均衡、ATS切換功能。柴油發(fā)電機(jī)組每2年或累計(jì)運(yùn)行250h應(yīng)進(jìn)行三濾、機(jī)油、冷凍液更換。III其他系統(tǒng)機(jī)房照度應(yīng)每年進(jìn)行檢查。備用照明設(shè)備宜半年進(jìn)行1次功能性檢查。配電線路布線系統(tǒng)宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不宜少于表5.2.16所列內(nèi)容。表123456母線槽連接處、電纜頭和電纜外皮應(yīng)每年進(jìn)行不小于1次溫度檢查。16浪涌保護(hù)器宜定期進(jìn)行功能檢查,對(duì)浪涌保護(hù)器的輸入開關(guān)進(jìn)行通斷試驗(yàn)。防雷與接地裝置的電氣連通性應(yīng)每年進(jìn)行1次檢測。接閃器應(yīng)每年進(jìn)行1次防銹、除銹維護(hù)。5.3通風(fēng)空調(diào)系統(tǒng)I冷源和水系統(tǒng)制冷機(jī)組應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.1所列內(nèi)容。表123季季月4年56季月78周季年年9水冷冷凝器、蒸發(fā)器應(yīng)根據(jù)端差進(jìn)行預(yù)測性維護(hù),板式換熱器應(yīng)根據(jù)運(yùn)行溫差或壓差進(jìn)行預(yù)測性維護(hù),維護(hù)內(nèi)容應(yīng)符合表5.3.2規(guī)定。表123冷卻塔應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.3所列內(nèi)容。表年1周23月季456年季年17水泵應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.4所列內(nèi)容。表序號(hào)12月水泵電動(dòng)機(jī)應(yīng)每半年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.5所列內(nèi)容。表1234水箱宜每月進(jìn)行1次表面清潔,宜每月檢查1次供水浮球閥及進(jìn)出閥門能否正常啟動(dòng)、關(guān)閉,如有銹蝕、失靈應(yīng)及時(shí)更換。定壓補(bǔ)水裝置宜每月進(jìn)行1次表面清潔和手自動(dòng)切換檢查,應(yīng)每年檢查1次電磁閥、安全閥。水處理系統(tǒng)宜每季度進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.8所列內(nèi)容。表1234空調(diào)水系統(tǒng)閥門、管道宜每半年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.9所列內(nèi)容。表12II機(jī)房空調(diào)和風(fēng)系統(tǒng)新風(fēng)機(jī)組、組合式空調(diào)機(jī)組、風(fēng)機(jī)盤管應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)不18應(yīng)少于表5.3.10所列內(nèi)容。表122345年季新風(fēng)機(jī)組、組合式空調(diào)機(jī)組空氣過濾器應(yīng)根據(jù)壓差進(jìn)行預(yù)測性維護(hù),表冷器應(yīng)根據(jù)運(yùn)行溫差或壓差進(jìn)行預(yù)測性維護(hù),維護(hù)內(nèi)容應(yīng)符合表5.3.11規(guī)定。表12新風(fēng)機(jī)組和組合式空調(diào)機(jī)組風(fēng)機(jī)電機(jī)應(yīng)每季度檢查1次電機(jī)傳動(dòng)皮帶,根據(jù)情況及時(shí)調(diào)整或更換,其他維護(hù)內(nèi)容應(yīng)符合本標(biāo)準(zhǔn)表5.3.5的規(guī)定??照{(diào)風(fēng)系統(tǒng)閥門、管道、風(fēng)口宜每年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.13所列內(nèi)容。表123事故排風(fēng)系統(tǒng)應(yīng)每半年進(jìn)行1次功能性測試。直接膨脹式和冷凍水型機(jī)房空調(diào)應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.3.15所列內(nèi)容。表季12345季年季年678季季年19機(jī)房漏水報(bào)警裝置應(yīng)每半年進(jìn)行1次有效性檢查,同時(shí)確保排水系統(tǒng)暢通。5.4消防系統(tǒng)數(shù)據(jù)中心消防系統(tǒng)應(yīng)按照《建筑消防設(shè)施的維護(hù)管理》GB25201要求進(jìn)行年度檢測。消防系統(tǒng)有效性宜定期委托有資質(zhì)的專業(yè)機(jī)構(gòu)進(jìn)行評(píng)估?;馂?zāi)自動(dòng)報(bào)警系統(tǒng)應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)內(nèi)容和周期應(yīng)符合現(xiàn)行消防國家標(biāo)準(zhǔn)的相關(guān)規(guī)定。消防水源、消防水泵、閥門、倒流防止器、消火栓、水泵接合器、過濾器等消防給水設(shè)施應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)內(nèi)容和周期應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB50974的相關(guān)規(guī)定。自動(dòng)噴水滅火系統(tǒng)的管線、閥門和控制功能等應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)的周期和內(nèi)容用應(yīng)符合《自動(dòng)噴水滅火系統(tǒng)施工及驗(yàn)收規(guī)范》GB50261、《細(xì)水霧滅火系統(tǒng)技術(shù)規(guī)范》GB50898的相關(guān)規(guī)定。氣體滅火系統(tǒng)及氣體探火管滅火系統(tǒng)應(yīng)定期進(jìn)行預(yù)防性維護(hù)。防排煙系統(tǒng)應(yīng)定期進(jìn)行預(yù)防性維護(hù)。防火卷簾、防火門、防火窗等防火分隔設(shè)施應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)的周期和內(nèi)容應(yīng)符合《防火卷簾、防火門、防火窗施工及驗(yàn)收規(guī)范》50877的相關(guān)規(guī)定。GB防火封堵系統(tǒng)應(yīng)結(jié)合防火封堵產(chǎn)品的要求進(jìn)行預(yù)防性維護(hù)。消防應(yīng)急照明與疏散指示系統(tǒng)應(yīng)定期進(jìn)行預(yù)防性維護(hù)。消防應(yīng)急廣播系統(tǒng)應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)的內(nèi)容和周期應(yīng)符合《火災(zāi)自動(dòng)報(bào)警系統(tǒng)施工及驗(yàn)收規(guī)范》GB50166的相關(guān)規(guī)定。建筑滅火器應(yīng)定期進(jìn)行預(yù)防性維護(hù),維護(hù)內(nèi)容和周期應(yīng)符合現(xiàn)行消防國家標(biāo)準(zhǔn)《建筑滅火器配置驗(yàn)收及檢查規(guī)范》GB50444的相關(guān)規(guī)定??諝猓ㄑ鯕猓┖粑鲬?yīng)每年進(jìn)行1次預(yù)防性維護(hù),檢查配置數(shù)量和有效期。205.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)環(huán)境和設(shè)備監(jiān)控系統(tǒng)應(yīng)每半年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.5.1內(nèi)容:表1233456環(huán)境和設(shè)備監(jiān)控系統(tǒng)維護(hù)過程中,應(yīng)采取必要的保護(hù)措施,確保被監(jiān)控系統(tǒng)與設(shè)備正常工作。II安全防范系統(tǒng)出入口控制系統(tǒng)應(yīng)每半年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.5.3所列內(nèi)容。表12345678入侵報(bào)警系統(tǒng)應(yīng)每半年進(jìn)行1次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.5.4內(nèi)容:表1234562178視頻監(jiān)控系統(tǒng)應(yīng)每半年進(jìn)行一次預(yù)防性維護(hù),維護(hù)不應(yīng)少于表5.5.5所列內(nèi)容:表123456789226制度6.1一般規(guī)定運(yùn)行維護(hù)團(tuán)隊(duì)?wèi)?yīng)制定運(yùn)行維護(hù)愿景和管理目標(biāo),并建立完整的運(yùn)行維護(hù)管理制度和程序。運(yùn)行維護(hù)管理應(yīng)明確物理范圍及邊界,并建立與周邊設(shè)施的協(xié)調(diào)機(jī)制及責(zé)權(quán)界限。運(yùn)行維護(hù)團(tuán)隊(duì)?wèi)?yīng)明確管理組織架構(gòu)和職責(zé)。運(yùn)行維護(hù)團(tuán)隊(duì)?wèi)?yīng)根據(jù)職責(zé)、工作范圍和工作任務(wù)配備相應(yīng)的人力、財(cái)務(wù)、物資和辦公資源。6.2制度體系運(yùn)行維護(hù)制度體系應(yīng)包括安全管理、運(yùn)行維護(hù)管理、質(zhì)量管理、應(yīng)急管理、能效管理、人力資源管理、財(cái)務(wù)管理、文件管理、績效管理、合規(guī)管理。安全管理內(nèi)容應(yīng)包括人員安全、職業(yè)健康、環(huán)境安全、信息安全。運(yùn)行維護(hù)管理內(nèi)容應(yīng)包括監(jiān)控管理、值班管理、巡檢管理、作業(yè)管理、供應(yīng)商管理、資產(chǎn)管理、變更管理、容量管理、事件管理和問題管理。質(zhì)量管理內(nèi)容應(yīng)包括質(zhì)量保證、質(zhì)量控制和持續(xù)改進(jìn)。應(yīng)急管理內(nèi)容應(yīng)包括風(fēng)險(xiǎn)識(shí)別、風(fēng)險(xiǎn)評(píng)估、預(yù)案制定、應(yīng)急演練。能效管理內(nèi)容應(yīng)包括能效數(shù)據(jù)的獲取、分析和運(yùn)行方案的優(yōu)化。人力資源管理內(nèi)容應(yīng)包括人員的選擇、培養(yǎng)、使用和發(fā)展規(guī)劃。財(cái)務(wù)管理內(nèi)容應(yīng)包括預(yù)算編制、預(yù)算執(zhí)行、核算和成本分析。文件管理內(nèi)容應(yīng)包括文件編制、審核、批準(zhǔn)、發(fā)布、使用、歸檔、變更、廢止和銷毀??冃Ч芾韮?nèi)容應(yīng)包括績效目標(biāo)制定和分解、績效監(jiān)控和評(píng)價(jià)、績效結(jié)果的應(yīng)用。合規(guī)管理內(nèi)容應(yīng)包括合規(guī)要求的識(shí)別、合規(guī)評(píng)估和處置。23本標(biāo)準(zhǔn)用詞說明1為便于在執(zhí)行本標(biāo)準(zhǔn)條文時(shí)區(qū)別對(duì)待,對(duì)要求嚴(yán)格程度不同的用詞說明如下:1)表示很嚴(yán)格,非這樣做不可的:2)表示嚴(yán)格,在正常情況下均應(yīng)這樣做的:3)表示允許稍有選擇,在條件許可時(shí)首先應(yīng)這樣做的:4)2……的規(guī)定”或“應(yīng)按……24引用標(biāo)準(zhǔn)名錄1234567《建筑消防設(shè)施的維護(hù)管理》GB25201《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB50974《自動(dòng)噴水滅火系統(tǒng)施工及驗(yàn)收規(guī)范》GB50261《細(xì)水霧滅火系統(tǒng)技術(shù)規(guī)范》GB50898《防火卷簾、防火門、防火窗施工及驗(yàn)收規(guī)范》GB50877《火災(zāi)自動(dòng)報(bào)警系統(tǒng)施工及驗(yàn)收規(guī)范》GB50166《建筑滅火器配置驗(yàn)收及檢查規(guī)范》GB5044425《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明中華人民共和國國家標(biāo)準(zhǔn)條文說明26《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明目次1總則.........................................................................................................................272術(shù)語.........................................................................................................................293基本規(guī)定.................................................................................................................303.1運(yùn)行維護(hù)范圍...................................................................................................293.2運(yùn)行維護(hù)基本要求...........................................................................................304運(yùn)行.........................................................................................................................324.1一般規(guī)定...........................................................................................................324.2電氣系統(tǒng)...........................................................................................................324.3通風(fēng)空調(diào)系統(tǒng)...................................................................................................334.4消防系統(tǒng)...........................................................................................................344.5智能化系統(tǒng).......................................................................................................354.6環(huán)境參數(shù)...........................................................................................................355維護(hù).........................................................................................................................395.1一般規(guī)定...........................................................................................................395.2電氣系統(tǒng)...........................................................................................................395.3通風(fēng)空調(diào)系統(tǒng)...................................................................................................395.4消防系統(tǒng)...........................................................................................................415.5智能化系統(tǒng).......................................................................................................446制度..........................................................................................................................466.1一般規(guī)定...........................................................................................................466.2制度體系...........................................................................................................4627《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明1總則1.0.1隨著大數(shù)據(jù)時(shí)代的到來,數(shù)據(jù)中心的發(fā)展出現(xiàn)了全新的局面。數(shù)據(jù)中心的數(shù)量和規(guī)模不斷擴(kuò)大,所面臨的管理與維護(hù)問題也越來越多,一旦出現(xiàn)管理不到位,或者運(yùn)行維護(hù)不及時(shí)的情況,就可能對(duì)業(yè)務(wù)帶來不可估量的損失。因此,精細(xì)化的運(yùn)行維護(hù)管理已成為數(shù)據(jù)中心運(yùn)行中不可或缺的重要一環(huán)。1.0.2運(yùn)行維護(hù)工作主要存在于已進(jìn)入正常使用階段的數(shù)據(jù)中心中,數(shù)據(jù)中心交付運(yùn)行維護(hù)團(tuán)隊(duì)前,應(yīng)為運(yùn)行維護(hù)團(tuán)隊(duì)順利接手進(jìn)行必要的準(zhǔn)備工作。28《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明2術(shù)語2.0.1本術(shù)語定義與《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB50174保持一致。2.0.2本術(shù)語定義與《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB50174保持一致。2.0.3運(yùn)行系指對(duì)數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備進(jìn)行的日常操作與狀態(tài)監(jiān)測,本標(biāo)準(zhǔn)將日常巡檢界定為運(yùn)行范疇,而將其他的周期性巡檢界定為維護(hù)范疇。運(yùn)行的目的是確保電子信息設(shè)備運(yùn)行環(huán)境的穩(wěn)定可靠,在此基礎(chǔ)上,數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備自身的安全高效運(yùn)行也必須得到保障。2.0.4在本標(biāo)準(zhǔn)中,將維護(hù)的內(nèi)容界定為預(yù)防性維護(hù)、預(yù)測性維護(hù)和維修,維修在國際上也有“糾正性維護(hù)”的叫法。2.0.5預(yù)防性維護(hù)是以預(yù)防故障和功能退化為目的,對(duì)設(shè)備進(jìn)行檢查、檢測、保養(yǎng),以確保數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備保持規(guī)定功能狀態(tài)所進(jìn)行的各種周期性維護(hù)活動(dòng)。2.0.6預(yù)測性維護(hù)是以運(yùn)行狀態(tài)為依據(jù)的維修與維護(hù)。在設(shè)備或系統(tǒng)運(yùn)行時(shí),對(duì)它的主要部位進(jìn)行定期或連續(xù)的狀態(tài)監(jiān)測和故障診斷,判定設(shè)備或系統(tǒng)所處的狀態(tài),預(yù)測其未來發(fā)展趨勢,針對(duì)可能發(fā)生的故障進(jìn)行維護(hù)活動(dòng)。預(yù)測性維護(hù)是構(gòu)成維護(hù)工作的內(nèi)容之一,但作為針對(duì)特定情況的維護(hù)活動(dòng),除制度一章有所要求外,在本標(biāo)準(zhǔn)中不對(duì)其具體工作內(nèi)容進(jìn)行規(guī)定。2.0.7事件是發(fā)生在數(shù)據(jù)中心基礎(chǔ)設(shè)施運(yùn)行維護(hù)過程中的任何計(jì)劃外的、不尋常的或者意外的事態(tài)。事件一般包括:1直接和立即影響數(shù)據(jù)中心基礎(chǔ)設(shè)施功能性的事態(tài);2危及數(shù)據(jù)中心基礎(chǔ)設(shè)施正常運(yùn)行的設(shè)備或者服務(wù)的故障。29《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明3基本規(guī)定3.1運(yùn)行維護(hù)范圍3.1.1本標(biāo)準(zhǔn)確定的運(yùn)行維護(hù)范圍是直接服務(wù)于電子信息設(shè)備的基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備,不包含一般性的建筑維護(hù)內(nèi)容。給水排水系統(tǒng)有關(guān)內(nèi)容分散于通風(fēng)空調(diào)系統(tǒng)與消防系統(tǒng)中。3.1.2本條所述供配電系統(tǒng)包括高壓供配電系統(tǒng)、低壓配電系統(tǒng)和變壓器,不間斷電源和后備電源系統(tǒng)系統(tǒng)包括UPS、直流電源系統(tǒng)、柴油發(fā)電機(jī)系統(tǒng),配電線路布線系統(tǒng)主要內(nèi)容為電纜和母線槽。3.1.3通風(fēng)空調(diào)系統(tǒng)子系統(tǒng)的劃分,設(shè)計(jì)人員和一線運(yùn)行維護(hù)人員的習(xí)慣不同,為兼顧二者并具有一定的條理性,本標(biāo)準(zhǔn)對(duì)通風(fēng)空調(diào)子系統(tǒng)進(jìn)行了較為宏觀的分類,分為了冷源和水系統(tǒng)、機(jī)房空調(diào)和風(fēng)系統(tǒng)兩大類。本標(biāo)準(zhǔn)主要涉及了常用的冷凍水型和直接膨脹式空調(diào)系統(tǒng),其他類型系統(tǒng)可參考相關(guān)運(yùn)行維護(hù)內(nèi)容。3.1.5按照《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017的規(guī)定,智能化系統(tǒng)包括總控中心、環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)、火災(zāi)自動(dòng)報(bào)警系統(tǒng)、數(shù)據(jù)中心基礎(chǔ)設(shè)施管理系統(tǒng)等智能化系統(tǒng)。根據(jù)運(yùn)行維護(hù)工作的特點(diǎn),本標(biāo)準(zhǔn)智能化系統(tǒng)部分重點(diǎn)關(guān)注環(huán)境和設(shè)備監(jiān)控系統(tǒng)和安全防范系統(tǒng),火災(zāi)自動(dòng)報(bào)警系統(tǒng)相關(guān)內(nèi)容在消防系統(tǒng)部分進(jìn)行規(guī)定。3.2運(yùn)行維護(hù)基本要求3.2.1運(yùn)行維護(hù)團(tuán)隊(duì)參與基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備安裝、調(diào)試和驗(yàn)證的過程,有利于對(duì)系統(tǒng)和設(shè)備情況的了解與掌握,在條件允許的情況下宜及早介入。3.2.2數(shù)據(jù)中心正式投入使用前,應(yīng)模擬運(yùn)行或故障場景以驗(yàn)證系統(tǒng)功能和性能是否達(dá)到設(shè)計(jì)要求。3.2.4《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB50174將數(shù)據(jù)中心分為、、C三級(jí),本標(biāo)準(zhǔn)的數(shù)據(jù)中心分級(jí)采用相應(yīng)的分級(jí)標(biāo)準(zhǔn)。3.2.6數(shù)據(jù)中心投入使用后,再進(jìn)行綜合系統(tǒng)測試有一定風(fēng)險(xiǎn)隱患,但應(yīng)定期對(duì)關(guān)鍵系統(tǒng)進(jìn)行測試,根據(jù)實(shí)施條件各系統(tǒng)可單獨(dú)測試也可進(jìn)行聯(lián)動(dòng)測試,一般宜結(jié)合應(yīng)急演練進(jìn)行。30《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明3.2.7運(yùn)行維護(hù)過程中,通過日常巡檢、維護(hù)檢查、系統(tǒng)監(jiān)測等各種方式發(fā)現(xiàn)的隱患、異常、故障、報(bào)警等問題,應(yīng)及時(shí)采取應(yīng)對(duì)措施。3.2.8基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備維護(hù)保養(yǎng)、發(fā)生故障及維修期間,不能正常發(fā)揮作用,在此期間的突發(fā)狀況系統(tǒng)無法應(yīng)對(duì),因此應(yīng)制定相應(yīng)的保障措施和應(yīng)急預(yù)案。3.2.9運(yùn)行維護(hù)人員技能素質(zhì)對(duì)數(shù)據(jù)中心安全、穩(wěn)定、可靠運(yùn)行有至關(guān)重要的作用,對(duì)不同的崗位應(yīng)有各自的從業(yè)資格要求,例如:低壓巡檢人員應(yīng)具有低壓電工證,高壓巡檢人員應(yīng)具有高壓進(jìn)網(wǎng)許可證,消防運(yùn)行維護(hù)人員可參照129號(hào))的相關(guān)要求。31《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明4運(yùn)行4.1一般規(guī)定4.1.2本條規(guī)定了運(yùn)行維護(hù)值班的時(shí)間要求,消防控制室的值班應(yīng)按國家有關(guān)法規(guī)要求執(zhí)行。4.1.4本條規(guī)定是為了使運(yùn)行人員能夠及時(shí)發(fā)現(xiàn)問題和隱患,最大限度地降低事故發(fā)生率。巡檢記錄包括報(bào)警、問題及處理情況。4.1.5本條對(duì)現(xiàn)場巡檢次數(shù)進(jìn)行了規(guī)定,主要針對(duì)遠(yuǎn)程監(jiān)控?zé)o法識(shí)別的異常聲響、氣味、振動(dòng)、痕跡等情況,同時(shí)對(duì)遠(yuǎn)程監(jiān)控系統(tǒng)進(jìn)行校驗(yàn),可以由人工,也可以由機(jī)器人等技術(shù)手段完成。4.1.7電能使用效率是數(shù)據(jù)中心最為關(guān)注的能效參數(shù),應(yīng)持續(xù)監(jiān)測數(shù)據(jù)中心各部分能耗,統(tǒng)計(jì)分析數(shù)據(jù)中心電能使用效率。通過優(yōu)化運(yùn)行可有效降低電氣系統(tǒng)和通風(fēng)空調(diào)系統(tǒng)能耗,從而提高整體電能使用效率。電氣系統(tǒng)應(yīng)根據(jù)負(fù)載情況調(diào)整運(yùn)行策略;通風(fēng)空調(diào)系統(tǒng)應(yīng)根據(jù)氣候條件、動(dòng)態(tài)負(fù)荷及能源供應(yīng)等條件,經(jīng)技術(shù)經(jīng)濟(jì)比較,按安全可靠、節(jié)能環(huán)保的原則,制定合理的全年運(yùn)行策略。4.1.8輪換使用可有效延長設(shè)備壽命,同時(shí)保持備用設(shè)備的正常狀態(tài)。4.2電氣系統(tǒng)I供配電系統(tǒng)4.2.1關(guān)于高壓有不同的規(guī)定,本標(biāo)準(zhǔn)中高壓系指交流400V以上的電壓等級(jí)。4.2.2配電室或值班室內(nèi)設(shè)置數(shù)據(jù)中心供配電系統(tǒng)圖,對(duì)幫助值班人員快速掌握數(shù)據(jù)中心供電關(guān)系、方便討論運(yùn)行過程中遇到的問題、輔助判斷故障原因等都有積極作用。系統(tǒng)圖可以固定在高壓配電室或值班室明顯位置。對(duì)于設(shè)有高壓開閉站的大中型數(shù)據(jù)中心宜設(shè)置模擬屏。4.2.3本條文規(guī)定為了幫助判斷設(shè)備重要性等級(jí)、提高運(yùn)行維護(hù)效率。4.2.4本條規(guī)定了高壓配電設(shè)備巡視檢查的內(nèi)容,這些巡檢內(nèi)容能反映出設(shè)備是否正常運(yùn)行。通過巡檢及早發(fā)現(xiàn)運(yùn)行中的異常,及時(shí)處理,避免引發(fā)重大事故。32《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明II不間斷和后備電源系統(tǒng)4.2.9本條溫濕度參考了《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017和產(chǎn)品手冊(cè)要求的參數(shù)范圍,直流電源系統(tǒng)指電壓等級(jí)為直流48V、240V、336V的系統(tǒng)。溫度條件在設(shè)備允許的情況下可適當(dāng)放寬,有利于空調(diào)系統(tǒng)節(jié)能運(yùn)行,故用4.2.14本條蓄電池指UPS蓄電池、直流電源蓄電池,不包括其它蓄電池。蓄電池室溫度采用了《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017要求的參數(shù)。4.2.15A級(jí)數(shù)據(jù)中心應(yīng)對(duì)每一節(jié)蓄電池進(jìn)行監(jiān)控,B級(jí)、C級(jí)數(shù)據(jù)中心一般對(duì)每一組蓄電池進(jìn)行監(jiān)控。4.2.17本條運(yùn)行對(duì)象為固定式柴油發(fā)電機(jī)組。III照明系統(tǒng)4.2.19一般情況下,應(yīng)急照明包括備用照明,但對(duì)數(shù)據(jù)中心而言,主機(jī)房和輔助區(qū)備用照明較為重要,在《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017中對(duì)備用照明設(shè)置有明確規(guī)定,本條將其單獨(dú)列出。同時(shí)為便于區(qū)分,將“消防應(yīng)急照明”列為運(yùn)行對(duì)象,特指為人員疏散和消防作業(yè)提供的照明。4.2.20照度要求在有人工作時(shí)光線充足,無人工作時(shí)滿足視頻監(jiān)控要求。4.3通風(fēng)空調(diào)系統(tǒng)I空調(diào)水系統(tǒng)4.3.1冷機(jī)、冷凍水泵、冷卻水泵、冷卻塔、電控水閥需協(xié)調(diào)工作,其啟停順序、臺(tái)數(shù)控制、變頻調(diào)節(jié)、水閥開關(guān)和開度直接關(guān)系到系統(tǒng)安全與能效。機(jī)房群控是以機(jī)房總能耗最小為控制目標(biāo)的節(jié)能運(yùn)行方式,采用自動(dòng)控制系統(tǒng)對(duì)各設(shè)備進(jìn)行聯(lián)合控制,實(shí)現(xiàn)協(xié)同運(yùn)行。4.3.2制冷機(jī)組出水溫度的設(shè)定值是為了滿足除濕和供冷需求,制冷系統(tǒng)在全年動(dòng)態(tài)運(yùn)行過程中,絕大部分時(shí)間處于非設(shè)計(jì)工況,在滿足需求的前提下,提高制冷機(jī)組的出水溫度可以大大提高機(jī)組效率。4.3.3數(shù)據(jù)中心冷負(fù)荷穩(wěn)定,需全年供冷。在過渡季和冬季,室外氣象條件適合時(shí),可減少制冷機(jī)組運(yùn)行,采用冷卻塔供冷方式,有利于降低空調(diào)系統(tǒng)能耗,33《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明達(dá)到節(jié)能的目的。4.3.4水泵和冷卻塔風(fēng)機(jī)變頻可在保證需求的前提下降低電機(jī)功耗,頻率越低節(jié)能效果越好,但對(duì)于電機(jī)沒有獨(dú)立散熱措施的情況,頻率過低會(huì)影響設(shè)備安全性,根據(jù)實(shí)際工程經(jīng)驗(yàn)運(yùn)行頻率一般不宜低于30Hz。4.3.5在嚴(yán)寒和寒冷地區(qū)冬季運(yùn)行的冷卻水系統(tǒng)需要采取可靠的防凍措施,外露的閥門管道需要做好保溫,必要時(shí)在管道加裝電伴熱帶,開式冷卻塔集水盤設(shè)置電加熱器。4.3.7此處的制冷機(jī)組包含了水冷冷水機(jī)組、風(fēng)冷冷水機(jī)組、吸收式冷水機(jī)組。II機(jī)房空調(diào)和風(fēng)系統(tǒng)4.3.11氣流組織是經(jīng)過凈化和熱濕處理的空氣從進(jìn)入房間到離開房間過程中在空間上的分布狀態(tài),如果氣流組織不合理,不能保證足夠的風(fēng)量送達(dá)發(fā)熱點(diǎn),則會(huì)造成局部過熱現(xiàn)象,可通過調(diào)節(jié)送回風(fēng)量、送風(fēng)方向等措施解決。4.3.12室外氣象條件的急劇變化、室內(nèi)冷負(fù)荷的變化,都有可能引起局部結(jié)露。結(jié)露往往出現(xiàn)在冷橋部位、送風(fēng)口等部位。除做好針對(duì)性的保溫措施外,還應(yīng)從系統(tǒng)運(yùn)行策略角度控制結(jié)露風(fēng)險(xiǎn),如:控制新風(fēng)處理參數(shù)、控制送風(fēng)參數(shù)、適時(shí)開啟除濕機(jī)等。4.3.13對(duì)于設(shè)有全新風(fēng)運(yùn)行措施的風(fēng)系統(tǒng)、氟泵系統(tǒng)、帶乙二醇干式冷卻器/乙二醇(或水)自然循環(huán)節(jié)能冷卻器的機(jī)房空調(diào),均應(yīng)在室外氣象條件適合時(shí),進(jìn)行自然供冷和壓縮機(jī)供冷模式的切換。4.3.15一般情況下,設(shè)備廠商能夠提供常用的監(jiān)控信息,對(duì)于采用第三方專業(yè)監(jiān)控系統(tǒng)的,可根據(jù)項(xiàng)目實(shí)際需求增加運(yùn)行監(jiān)控內(nèi)容。上表中的報(bào)警包含了各種主要的保護(hù)報(bào)警:高低壓報(bào)警、氣流故障報(bào)警、溫濕度過高/過低報(bào)警、電加熱高溫報(bào)警、加濕器報(bào)警、濾網(wǎng)淤塞報(bào)警、系統(tǒng)斷水、漏水報(bào)警、電源故障報(bào)警等。4.4消防系統(tǒng)4.4.1消防控制室內(nèi)設(shè)置的消防設(shè)備應(yīng)包括:火災(zāi)報(bào)警控制器、消防聯(lián)動(dòng)控制器、消防控制室圖形顯示裝置、消防電話總機(jī)、消防應(yīng)急廣播控制裝置、消防應(yīng)急照明和疏散指示系統(tǒng)控制裝置、消防電源監(jiān)控器等設(shè)備,或具有相應(yīng)功能34《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明的組合設(shè)備。消防控制室的管理、值班記錄及應(yīng)急操作程序,應(yīng)符合《建筑消防設(shè)施的維護(hù)管理GB252012010)與《消防控制室通用技術(shù)要求》(GB255062010)的規(guī)定。對(duì)于火災(zāi)隱患的極早期探測,宜配置便攜式極早期火災(zāi)定位器,以便簡單、快速發(fā)現(xiàn)火災(zāi)隱患點(diǎn),并及時(shí)采取消除措施,最大限度地減少損失。采用氣體滅火系統(tǒng)的數(shù)據(jù)中心,宜配置消防鋼瓶爆裂預(yù)警探測系統(tǒng),以實(shí)時(shí)在線監(jiān)測消防鋼瓶自身的安全狀態(tài)。4.4.2本條提出的消防巡檢周期和內(nèi)容是基本要求,各單位可結(jié)合工作、生產(chǎn)、經(jīng)營等實(shí)際情況適當(dāng)增加巡檢周期和內(nèi)容。本條所列巡檢內(nèi)容主要參考以下標(biāo)準(zhǔn):1)《建筑消防設(shè)施的維護(hù)管理》GB2520120102)《消防控制室通用技術(shù)要求》GB2550620103)《火災(zāi)自動(dòng)報(bào)警系統(tǒng)施工及驗(yàn)收規(guī)范》GB5016620074)《火災(zāi)探測報(bào)警產(chǎn)品的維修保養(yǎng)與報(bào)廢》GB2983720135)《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB509746)《自動(dòng)噴水滅火系統(tǒng)施工及驗(yàn)收規(guī)范》GB5026120057)《氣體滅火系統(tǒng)施工及驗(yàn)收規(guī)范》GB20078)《細(xì)水霧滅火系統(tǒng)技術(shù)規(guī)范》GB5089820139)《防火卷簾、防火門、防火窗施工及驗(yàn)收規(guī)范》GB5087710)11)《建筑滅火器配置驗(yàn)收及檢查規(guī)范》GB504444.4.3動(dòng)火作業(yè)的火災(zāi)危險(xiǎn)性較大,應(yīng)該是巡查的重點(diǎn)。動(dòng)火作業(yè)應(yīng)有嚴(yán)格的審批制度;動(dòng)火作業(yè)過程中,應(yīng)保證配套消防設(shè)施和措施到位,現(xiàn)場監(jiān)管人員嚴(yán)格落實(shí)相應(yīng)管理制度;動(dòng)火作業(yè)完成應(yīng)恢復(fù)作業(yè)區(qū)域。對(duì)經(jīng)過批準(zhǔn)的動(dòng)火作業(yè),在動(dòng)火期間應(yīng)加強(qiáng)對(duì)動(dòng)火區(qū)域的巡檢。巡檢發(fā)現(xiàn)的問題應(yīng)立刻上報(bào)外,并責(zé)令動(dòng)火人即刻糾正,未糾正前應(yīng)責(zé)令停止動(dòng)火作業(yè)。4.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)35《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明4.5.1環(huán)境和設(shè)備監(jiān)控系統(tǒng)運(yùn)行參數(shù)和控制邏輯是機(jī)房環(huán)境穩(wěn)定可靠和通風(fēng)空調(diào)系統(tǒng)、電氣系統(tǒng)安全高效運(yùn)行的保證,應(yīng)根據(jù)相關(guān)標(biāo)準(zhǔn)由專業(yè)人員設(shè)置,并在運(yùn)行過程中根據(jù)實(shí)際情況和使用管理要求進(jìn)行優(yōu)化。運(yùn)行參數(shù)設(shè)定值和聯(lián)動(dòng)邏輯的修改應(yīng)遵循變更管理程序,并設(shè)置相應(yīng)權(quán)限,禁止擅自修改。4.5.21)數(shù)據(jù)中心因?yàn)镮T設(shè)備類型和IT業(yè)務(wù)量的不同,不同區(qū)域的電能使用效率可能會(huì)有較大差異。2)使用效率可和服務(wù)器負(fù)載、網(wǎng)絡(luò)流量等IT業(yè)務(wù)量綜合分析,建立多層次的評(píng)價(jià)體系。II安全防范系統(tǒng)4.5.3系統(tǒng)授權(quán)的審批、設(shè)置和執(zhí)行應(yīng)由互相獨(dú)立的崗位完成。應(yīng)對(duì)門禁系統(tǒng)的授權(quán)進(jìn)行核查,建立機(jī)制,確保使用人不再需要時(shí),能夠及時(shí)撤消門禁授權(quán)。4.5.4出入口的視頻監(jiān)控宜與門禁系統(tǒng)聯(lián)動(dòng)控制,當(dāng)有刷卡事件發(fā)生時(shí),確保相應(yīng)的視頻圖像切換至監(jiān)控屏幕。4.5.5入侵報(bào)警系統(tǒng)宜與視頻監(jiān)控系統(tǒng)和燈光控制系統(tǒng)聯(lián)動(dòng)控制,當(dāng)有入侵事件發(fā)生時(shí),確保開啟相應(yīng)區(qū)域照明,并將對(duì)應(yīng)視頻圖像切換至監(jiān)控屏幕。4.5.6調(diào)整探測器的靈敏度、探測范圍、探測角度,確保設(shè)備處在最好狀態(tài)或保持應(yīng)有效果。4.5.7視頻監(jiān)控系統(tǒng)重點(diǎn)監(jiān)控對(duì)象可根據(jù)需要適時(shí)調(diào)整,相關(guān)調(diào)整應(yīng)按照標(biāo)準(zhǔn)規(guī)范、技術(shù)手冊(cè)和使用管理要求,不得影響監(jiān)控效果。視頻監(jiān)控系統(tǒng)應(yīng)建立視頻輪巡機(jī)制,確保每路視頻信號(hào)在一定時(shí)間內(nèi)都能夠顯示在監(jiān)控屏幕上,及時(shí)發(fā)現(xiàn)視頻監(jiān)控故障。4.6環(huán)境參數(shù)4.6.1溫度和濕度是保證電子信息設(shè)備正常工作的重要環(huán)境指標(biāo),需要控制在一定范圍內(nèi)。雖然電子信息設(shè)備芯片對(duì)溫度的耐受范圍較大,但其工作溫濕度會(huì)對(duì)其壽命產(chǎn)生影響,長時(shí)間工作在不合理的溫濕度水平下會(huì)不同程度的降低其壽命及可靠性。本標(biāo)準(zhǔn)的溫度數(shù)值參考國家標(biāo)準(zhǔn)《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017,18~27℃的溫度范圍是綜合考慮暖通系統(tǒng)運(yùn)行能耗、電子信息設(shè)備維修費(fèi)用等各種因素而提出的。在空氣濕度方面,相對(duì)濕度過高會(huì)影響數(shù)據(jù)中心設(shè)備的安全運(yùn)行與設(shè)備使36《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明用壽命;而相對(duì)濕度過低時(shí),可能導(dǎo)致靜電充電,進(jìn)而損壞設(shè)備或影響其正常運(yùn)行。國家標(biāo)準(zhǔn)《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017規(guī)定了露點(diǎn)溫度與相對(duì)GB/T28872011中對(duì)B級(jí)機(jī)房的相對(duì)濕度規(guī)定為35%~65%。考慮到數(shù)據(jù)中心空氣濕度的在線監(jiān)測多為相對(duì)濕度、而非露點(diǎn)溫度,故本條提出了建議相對(duì)濕度范圍。結(jié)合調(diào)研,考慮到全國范圍適用性,本標(biāo)準(zhǔn)推薦相對(duì)濕度采用35%-65%的范圍。4.6.2主機(jī)房維持正壓的目的是為了防止外部空氣進(jìn)入主機(jī)房,以減少主機(jī)房外部空氣溫濕度及顆粒物對(duì)主機(jī)房室內(nèi)環(huán)境的影響。從實(shí)際運(yùn)行角度,只要主機(jī)房保持對(duì)相鄰區(qū)域的正壓即可滿足上述要求。4.6.3數(shù)據(jù)中心需要嚴(yán)格避免發(fā)生結(jié)露現(xiàn)象。結(jié)露產(chǎn)生的水就可能毀壞電子元件,帶來嚴(yán)重后果。4.6.5機(jī)房中會(huì)經(jīng)常有工作人員進(jìn)行調(diào)試、檢測、維護(hù)等技術(shù)操作,在進(jìn)行技術(shù)操作期間,機(jī)房內(nèi)需滿足此類技術(shù)操作所要求的照度水平,在其他無人員操作時(shí)間,機(jī)房內(nèi)需滿足系統(tǒng)監(jiān)控所要求的照度水平。4.6.6為了保護(hù)工作人員的聽力與健康,對(duì)于有人值守的主機(jī)房和輔助區(qū)且在長期固定工作位置的噪聲值進(jìn)行限制。限值參考國家標(biāo)準(zhǔn)《數(shù)據(jù)中心設(shè)計(jì)規(guī)范》GB501742017的規(guī)定。4.6.7本條滿足現(xiàn)行國家標(biāo)準(zhǔn)《室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)》GB18883中關(guān)于室內(nèi)空氣中二氧化碳日平均濃度的規(guī)定。數(shù)據(jù)中心雖然是以信息設(shè)備為主要服務(wù)對(duì)象的,但像控制室、值班室等有人長時(shí)間值守的區(qū)域應(yīng)該滿足符合人員健康要求的最基本衛(wèi)生標(biāo)準(zhǔn)。4.6.8數(shù)據(jù)中心雖然是以電子信息設(shè)備為主要服務(wù)對(duì)象的,但也有少量操作人員、測試人員、值班人員等,因此也應(yīng)該滿足室內(nèi)污染物濃度的要求。氡、甲醛、苯、氨、總揮發(fā)性有機(jī)物等五類物質(zhì)污染物的濃度限量應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)》GB/T18883的要求,詳見下表。表1333111苯CH6637《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明338氡38《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明5維護(hù)5.1一般規(guī)定5.1.3在實(shí)際操作過程中,很多運(yùn)行維護(hù)單位對(duì)保修期滿的設(shè)備,沒有及時(shí)采取應(yīng)對(duì)措施,導(dǎo)致兩個(gè)維保周期間出現(xiàn)空白期,需要延續(xù)維護(hù)保養(yǎng)服務(wù)的,應(yīng)及時(shí)購買。5.1.6各設(shè)備內(nèi)置時(shí)鐘隨著時(shí)間推移會(huì)產(chǎn)生誤差,為了保證設(shè)備報(bào)警時(shí)間與事件處理的一致性,需要定期校準(zhǔn)時(shí)間。5.2電氣系統(tǒng)I高低壓供配電系統(tǒng)5.2.1由于供配電設(shè)備操作的風(fēng)險(xiǎn)性,對(duì)重要的操作和維護(hù)有特殊的規(guī)定和要求,因此應(yīng)遵守國家、行業(yè)和地區(qū)相關(guān)安全法規(guī)和標(biāo)準(zhǔn)的規(guī)定。5.2.2各地供電部門對(duì)于高壓供配電設(shè)備的檢測時(shí)間和內(nèi)容有不同的要求,應(yīng)按當(dāng)?shù)毓╇姴块T要求執(zhí)行。一般檢測內(nèi)容宜符合表2規(guī)定。表21234567895.2.3本條規(guī)定了高壓配電設(shè)備的預(yù)防性維護(hù)時(shí)間和內(nèi)容,一般宜按本標(biāo)準(zhǔn)第5.2.2條的規(guī)定并結(jié)合供電部門檢測進(jìn)行。維護(hù)內(nèi)容中,絕緣管材包括穿墻套管材料、絕緣板、電纜頭封包材料、互感器絕緣材料等。39《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明5.2.5本條規(guī)定了電力變壓器的預(yù)防性維護(hù)周期和內(nèi)容。維護(hù)內(nèi)容中,接地檢查指檢查中性點(diǎn)和保護(hù)接地有無銹蝕、氧化、接地是否良好、端子有無松動(dòng)。II不間斷電源和備用電源系統(tǒng)5.2.12本條規(guī)定了柴油發(fā)電機(jī)的帶載測試周期和內(nèi)容,驗(yàn)證柴油發(fā)電機(jī)組的帶載能力、切換邏輯和負(fù)載均衡。帶載測試時(shí),應(yīng)采取必要的防護(hù)措施,避免高溫觸發(fā)消防自動(dòng)噴淋系統(tǒng)。III其他系統(tǒng)5.2.15對(duì)于備用照明的“功能性檢查”主要檢查照明設(shè)備是否能夠點(diǎn)亮。消防應(yīng)急照明應(yīng)按本標(biāo)準(zhǔn)第5.4.10條規(guī)定執(zhí)行。5.2.17本條規(guī)定了母線槽連接處、電纜頭和電纜外皮溫度檢查的周期,母線槽連接處測試溫度與前次測試結(jié)果比較應(yīng)無明顯變化,電纜頭和電纜外皮溫度應(yīng)符合現(xiàn)行電力行業(yè)標(biāo)準(zhǔn)《電力電纜線路運(yùn)行規(guī)程》DL/T1253的相關(guān)規(guī)定。5.2.18雷雨季節(jié)前宜檢查浪涌保護(hù)器和開關(guān)確保功能正常,雷雨季節(jié)浪涌保護(hù)器和開關(guān)可能失效,宜定期檢查更換。5.2.19測量接地電阻是檢測防雷與接地裝置電氣連通性的一種方法,應(yīng)由具有專業(yè)資質(zhì)的機(jī)構(gòu)進(jìn)行,并出具檢測報(bào)告。5.2.20接閃器包括接閃桿、接閃帶、接閃網(wǎng)等。5.3通風(fēng)空調(diào)系統(tǒng)I冷源和水系統(tǒng)5.3.1潤滑油系統(tǒng)保養(yǎng)內(nèi)容:檢查油泵、密封和油泵電機(jī)及油系統(tǒng)其他部件,如油冷卻器、過濾器和電磁閥等。冷媒管路的維護(hù)包括:(1)檢查機(jī)組本體各傳感器插入孔、連接處、閥門處有無制冷劑泄漏或潤滑油泄漏現(xiàn)象;檢查制冷劑保有量是否充足,并根據(jù)運(yùn)行情況進(jìn)行制冷劑的充放。(2)檢查制冷劑泄漏報(bào)警裝置是否運(yùn)行可靠,與報(bào)警裝置聯(lián)鎖的通風(fēng)系統(tǒng)運(yùn)轉(zhuǎn)是否正常。40《數(shù)據(jù)中心設(shè)施運(yùn)行維護(hù)標(biāo)準(zhǔn)》條文說明傳感器的校準(zhǔn)和更換:傳感器應(yīng)定期進(jìn)行校準(zhǔn),且其工作時(shí)段應(yīng)在校準(zhǔn)有效期內(nèi)。采用精度更高的儀器對(duì)相應(yīng)傳感器進(jìn)行讀數(shù)校準(zhǔn),使實(shí)測值與校核值一致,無法校準(zhǔn)的傳感器應(yīng)及時(shí)更換。同時(shí)還需檢查各接點(diǎn)是否牢固,探頭插接處是否密封良好。5.3.2水冷冷凝器和蒸發(fā)器需要根據(jù)端差來判斷是否需要進(jìn)行內(nèi)部清洗,一般當(dāng)排氣壓力對(duì)應(yīng)的飽和溫度與冷卻水出水溫度差值大于2.5~3℃時(shí)宜清洗冷凝器;當(dāng)吸氣壓力對(duì)應(yīng)的飽和溫度與冷凍水出水溫度差值大于2.5~3℃時(shí)宜清洗蒸發(fā)器。數(shù)據(jù)中心空調(diào)系統(tǒng)常用的是板式換熱器,當(dāng)根據(jù)運(yùn)行溫差或壓差判斷板式換熱器臟堵程度嚴(yán)重時(shí),需要拆開進(jìn)行清洗,并根據(jù)板片表面附著物的種類確定清洗方法。使用時(shí)間較長的板片還應(yīng)采用透光和著色法進(jìn)行檢測,以找出目測無法確定是否滲漏的板片。重新組裝后還應(yīng)進(jìn)行水壓試驗(yàn)確保能正常工作。II機(jī)房空調(diào)和風(fēng)系統(tǒng)5.3.14功能性測試內(nèi)容包括機(jī)房氣密性測試、氣體滅火系統(tǒng)的聯(lián)動(dòng)功能測試和高位泄壓閥性能測試。5.3.15機(jī)房空調(diào)的加濕器有多種形式,下面以常見的紅外加濕器、電極加濕器進(jìn)行說明。紅外加濕器的維護(hù)要點(diǎn)為:檢查加濕水槽水位;檢查接水盤內(nèi)礦
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024-2030年中國地毯行業(yè)市場發(fā)展趨勢及投資需求預(yù)測報(bào)告
- 2024-2030年中國回程車輛行業(yè)供需狀況發(fā)展戰(zhàn)略規(guī)劃分析報(bào)告
- 2024-2030年中國售電公司行業(yè)未來發(fā)展創(chuàng)新調(diào)研規(guī)劃研究報(bào)告
- 2024年版權(quán)許可與內(nèi)容分發(fā)合同
- 湄洲灣職業(yè)技術(shù)學(xué)院《特殊學(xué)校教材教法》2023-2024學(xué)年第一學(xué)期期末試卷
- 2024年某科技公司與某游戲公司關(guān)于游戲開發(fā)的合同
- 中國速滑“勞?!表n梅笑談冬奧
- 呂梁學(xué)院《信息界面設(shè)計(jì)》2023-2024學(xué)年第一學(xué)期期末試卷
- 2024年度結(jié)婚典禮拍攝合同
- 2024年標(biāo)志性樓頂LED燈光字安裝制作合作協(xié)議版B版
- 全生命周期成本管理與優(yōu)化
- 質(zhì)量損失培訓(xùn)課件
- 《維修車間管理》課件
- 北京市海淀區(qū)101中學(xué)2023年數(shù)學(xué)七年級(jí)第一學(xué)期期末經(jīng)典試題含解析
- 高處作業(yè)吊籃危險(xiǎn)源辨識(shí)及風(fēng)險(xiǎn)評(píng)價(jià)表
- 房地產(chǎn)開發(fā)項(xiàng)目 水土保持方案
- 八年級(jí)歷史上冊(cè) 第一學(xué)期期末考試卷(人教福建版)
- 人教版高中必修一(教案)Unit-2-Travelling-Around-Discovering-U
- 項(xiàng)目電氣工程師總結(jié)
- 陳赫賈玲小品《歡喜密探》臺(tái)詞劇本
- 部編版語文九年級(jí)下冊(cè)-第三單元古詩文默寫-理解性默寫(排版-附答案)
評(píng)論
0/150
提交評(píng)論