廣東某廠區(qū)地下管網(wǎng)安裝作業(yè)指導(dǎo)書(shū)_第1頁(yè)
廣東某廠區(qū)地下管網(wǎng)安裝作業(yè)指導(dǎo)書(shū)_第2頁(yè)
廣東某廠區(qū)地下管網(wǎng)安裝作業(yè)指導(dǎo)書(shū)_第3頁(yè)
廣東某廠區(qū)地下管網(wǎng)安裝作業(yè)指導(dǎo)書(shū)_第4頁(yè)
廣東某廠區(qū)地下管網(wǎng)安裝作業(yè)指導(dǎo)書(shū)_第5頁(yè)
已閱讀5頁(yè),還剩55頁(yè)未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

目錄1、工程概況········································································331.1工程概況況······································································331.2工程范圍圍及工程量·····························································31.3施工工期期······································································332、編制依據(jù)·······································································33、作業(yè)前的條條件和準(zhǔn)備····························································43.1技術(shù)準(zhǔn)備備······································································443.2作業(yè)人員員······································································553.3作業(yè)工機(jī)機(jī)具····································································73.4材料和設(shè)設(shè)備····································································83.5工序交接接·····································································1334、作業(yè)程序和和方法······························································134.1廠區(qū)室外外消防、工業(yè)業(yè)、生活給水水管道安裝施施工工序··························134.2廠區(qū)室外外生活污水管管道安裝施工工工序········································1194.3管溝施工工·····································································2004.4質(zhì)量控制制計(jì)劃································································2214.5施工過(guò)程程控制規(guī)范····························································245、質(zhì)量控制點(diǎn)點(diǎn)的設(shè)置和質(zhì)質(zhì)量通病預(yù)防防···········································245.1質(zhì)量目標(biāo)標(biāo)·····································································2445.2質(zhì)量控制制及質(zhì)量通病病預(yù)防····················································245.3室外管管網(wǎng)安裝的控控制點(diǎn)的設(shè)置置··············································2245.4質(zhì)量標(biāo)標(biāo)準(zhǔn)及要求······························································256、作業(yè)的安全全和作業(yè)的安安全危害因素素辨識(shí)和控制制································256.1作業(yè)的安安全要求······························································256.2施工危險(xiǎn)險(xiǎn)因素和環(huán)境境因素辨識(shí)及及對(duì)策表······································277、《二十五項(xiàng)項(xiàng)反措》和《強(qiáng)強(qiáng)條》要求及及保證措施································307.1《施工現(xiàn)現(xiàn)場(chǎng)臨時(shí)用電電安全技術(shù)規(guī)規(guī)范》··········································307.2《建筑機(jī)機(jī)械使用安全全技術(shù)規(guī)程》··············································3317.3《二十五五項(xiàng)反措》要要求及保證措措施···········································32廠區(qū)地下管網(wǎng)安安裝作業(yè)指導(dǎo)導(dǎo)書(shū)1、工程概況1.1工程概況況廣東某惠州大亞亞灣熱電一期期為2×300MW級(jí)燃煤機(jī)組工程程,我公司承承建輸煤系統(tǒng)統(tǒng)工程的施工工,本作業(yè)指指導(dǎo)書(shū)用于輸輸煤系統(tǒng)地下下管網(wǎng)的管道道及設(shè)備的安安裝工程。我公司承擔(dān)的廣廣東某惠州大大亞灣熱電一一期2×300MW級(jí)燃煤機(jī)組工程程輸煤系統(tǒng)地地下管網(wǎng)安裝裝主要包括消消防、工業(yè)、生生活給水、生生活污水管道道及附屬設(shè)備備的安裝。1.2工程范圍圍及工程量本項(xiàng)目的作業(yè)范范圍包括:消消防、工業(yè)、生生活給水、生生活污水管道道布置及安裝裝,及其附屬屬設(shè)備閥門(mén)的的安裝。工程量見(jiàn)施工材材料統(tǒng)計(jì)表。1.3施工工期期:管溝開(kāi)挖,廠區(qū)區(qū)室外消防、工工業(yè)、生活給給水及生活污污水管道布置置、安裝及組組合。共計(jì)40天。2、編制依據(jù)參考資料表序號(hào)資料名稱(chēng)編號(hào)備注1《輸煤系統(tǒng)施工工組織設(shè)計(jì)》2《電力建設(shè)安全全工作規(guī)程》3《火電施工質(zhì)量量檢驗(yàn)及評(píng)定定標(biāo)準(zhǔn)》4《電力建設(shè)施工工及驗(yàn)收技術(shù)術(shù)規(guī)范》5廠區(qū)室外消防給給水管道平面面布置圖6廠區(qū)室外消火栓栓管道系統(tǒng)圖圖7廠區(qū)室外生活污污水管道平面面布置圖8廠區(qū)室外生活污污水管道系統(tǒng)統(tǒng)圖9廠區(qū)室外工業(yè)水水、生活水管管道平面布置置圖10廠區(qū)室外工業(yè)水水管系統(tǒng)圖序號(hào)資料名稱(chēng)編號(hào)備注11廠區(qū)室外生活水水管系統(tǒng)圖12甲方委托、設(shè)計(jì)計(jì)變更等技術(shù)術(shù)圖紙、資料料13電力建設(shè)工程施施工質(zhì)量監(jiān)督督(安裝工程程)14設(shè)備安裝工程禁禁忌手冊(cè)15以往類(lèi)似工程的的施工技術(shù)資資料16《室外給水管道道附屬構(gòu)筑物物》17《室外消火栓安安裝》18《埋地鋼管的防防腐》19《溝槽開(kāi)挖及回回填、管道墊墊層》20《涂裝前鋼材表表面銹蝕等級(jí)級(jí)和除銹等級(jí)級(jí)》21《石油化工給排排水管道工程程施工及驗(yàn)收收規(guī)范》22《給水鋼絲網(wǎng)骨骨架塑料(聚聚乙烯)復(fù)合合管管道工程程技術(shù)規(guī)程》23《給水排水管道道工程施工及及驗(yàn)收規(guī)范》24《磚砌化糞池》25《排水檢查井》26《埋地高密度聚聚乙烯中空壁壁纏繞結(jié)構(gòu)排排水管道工程程技術(shù)規(guī)程》27《埋地硬聚氯乙乙烯排水管道道工程技術(shù)規(guī)規(guī)程》3、作業(yè)前的條條件和準(zhǔn)備3.1技術(shù)準(zhǔn)備備施工圖紙齊全,由由安裝技術(shù)負(fù)負(fù)責(zé)人組織技技術(shù)員進(jìn)行與與室外消防、工工業(yè)水、生活活水及生活污污水管道安裝裝施工相關(guān)的的圖紙審核,并并由項(xiàng)目部工工程管理部門(mén)門(mén)組織與室外外消防、工業(yè)業(yè)水、生活水水及生活污水水管道安裝相相關(guān)專(zhuān)業(yè)進(jìn)行行圖紙會(huì)審,圖圖紙經(jīng)審核無(wú)無(wú)誤。施工方案已確定定,并經(jīng)項(xiàng)目目部專(zhuān)業(yè)技術(shù)術(shù)負(fù)責(zé)人審核核批準(zhǔn)。組合平臺(tái)、起吊吊工具等施工工措施、方案案設(shè)計(jì)完畢,施施工圖、材料料預(yù)算等經(jīng)審審核批準(zhǔn)。作業(yè)指導(dǎo)書(shū)編制制完畢。技術(shù)人員按照施施工作業(yè)指導(dǎo)導(dǎo)書(shū),已對(duì)施施工人員進(jìn)行行技術(shù)、質(zhì)量量、安全交底底,并進(jìn)行交交底雙簽字。3.2作業(yè)人員員施工前應(yīng)建立健健全的質(zhì)量管管理體系和工工程質(zhì)量檢測(cè)測(cè)制度。施工組織應(yīng)設(shè)立立技術(shù)組、質(zhì)質(zhì)安組、管道道班、電氣焊焊班、開(kāi)挖班班、測(cè)量班等等。施工人員數(shù)量根根據(jù)工程規(guī)模模和工程量的的大小確定,一一般應(yīng)配備的的人員有:給給排水專(zhuān)業(yè)技技術(shù)人員,測(cè)測(cè)量工、管道道工、電焊工工、氣焊工、起起重工、油漆漆工等。作業(yè)人員配置、資資格序號(hào)作業(yè)人員工種數(shù)量資格要求資質(zhì)1技術(shù)員1能夠?qū)徢灞卷?xiàng)目目施工圖紙,領(lǐng)領(lǐng)會(huì)設(shè)計(jì)思想想,掌握施工工工藝,熟悉悉施工質(zhì)量和和安環(huán)要求。助工以上2班組長(zhǎng)2熟悉本項(xiàng)目施工工的工藝流程程,能有效組組織好施工人人員按照作業(yè)業(yè)指導(dǎo)書(shū)的要要求施工,熟熟悉施工質(zhì)量量和安環(huán)要求求。中級(jí)工3安裝工12熟練掌握本項(xiàng)目目的技術(shù)、工工藝要求,知知道施工質(zhì)量量、安環(huán)要求求。中、初級(jí)工4測(cè)量工2熟練掌握測(cè)量的的基本知識(shí)和和技能、施工工工藝精度要要求。中級(jí)工5焊工4熟悉焊接工藝及及相關(guān)要求,具具有與焊接項(xiàng)項(xiàng)目相符合的的焊工合格證證書(shū)。持證6起重工4熟悉所操作吊車(chē)車(chē)的機(jī)械性能能,技術(shù)熟練練。持證7油漆工4熟練掌握本項(xiàng)目目的技術(shù)、工工藝要求,知知道施工質(zhì)量量、安環(huán)要求求。中、初級(jí)工作業(yè)人員職責(zé)分分工和權(quán)限序號(hào)崗位名稱(chēng)職責(zé)分工和權(quán)限限1技術(shù)員全面負(fù)責(zé)輸煤系系統(tǒng)室外消防防、工業(yè)水、生生活水及生活活污水管道安安裝的技術(shù)工工作,參加相相關(guān)圖紙會(huì)審審,處理設(shè)計(jì)計(jì)變更,編制制施工作業(yè)指指導(dǎo)書(shū)、施工工預(yù)算、技術(shù)術(shù)、安全措施施,并主持技技術(shù)交底工作作。深入現(xiàn)場(chǎng)指導(dǎo)施施工,及時(shí)發(fā)發(fā)現(xiàn)和解決施施工中的技術(shù)術(shù)、質(zhì)量隱患患,按照指導(dǎo)導(dǎo)書(shū)的要求指指導(dǎo)施工。配合班組長(zhǎng)進(jìn)行行施工驗(yàn)收的的自檢工作。記錄、整理施工工記錄和驗(yàn)收收記錄。對(duì)違章操作,有有權(quán)制止,嚴(yán)嚴(yán)重者可令其其停工,并及及時(shí)向有關(guān)領(lǐng)領(lǐng)導(dǎo)匯報(bào)。2班組長(zhǎng)負(fù)責(zé)組織安排施施工人力,物物力。嚴(yán)格按按照作業(yè)指導(dǎo)導(dǎo)書(shū)的施工工工藝要求,質(zhì)質(zhì)量要求和安安全環(huán)境要求求進(jìn)行施工。全全面負(fù)責(zé)質(zhì)量量、安全工作作。做好輸煤系統(tǒng)室室外消防、工工業(yè)水、生活活水及生活污污水管道安裝裝的質(zhì)量自檢檢和工序交接接工作。施工過(guò)程中,圖圖紙不清不施施工,材料不不合格不施工工,技術(shù)、安安全不交底不不施工,上一一級(jí)工序驗(yàn)收收不合格不施施工。發(fā)生質(zhì)量、安全全事故立即上上報(bào),同時(shí)組組織本班級(jí)組組職工按照“三不放過(guò)”的原則認(rèn)真真分析。3作業(yè)人員嚴(yán)格按照作業(yè)指指導(dǎo)書(shū)的施工工工藝要求、質(zhì)質(zhì)量要求和安安全環(huán)境要求求進(jìn)行施工。愛(ài)護(hù)施工所用工工器具,嚴(yán)格格按照操作規(guī)規(guī)程作業(yè)。發(fā)生質(zhì)量、安全全事故應(yīng)保護(hù)護(hù)好現(xiàn)場(chǎng),并并迅速告知有有關(guān)領(lǐng)導(dǎo),做做好處理工作作。有疑難問(wèn)題有權(quán)權(quán)向技術(shù)人員員、班組長(zhǎng)請(qǐng)請(qǐng)示解決辦法法,對(duì)自己的的施工質(zhì)量全全面負(fù)責(zé),對(duì)對(duì)不正確、不不明確的指揮揮有權(quán)不執(zhí)行行。序號(hào)崗位名稱(chēng)職責(zé)分工和權(quán)限限4質(zhì)檢人員熟悉相關(guān)圖紙內(nèi)內(nèi)容和有關(guān)質(zhì)質(zhì)量標(biāo)準(zhǔn),參參加圖紙會(huì)審審,技術(shù)交底底。深入施工現(xiàn)場(chǎng),掌掌握工程進(jìn)度度及質(zhì)量情況況,按照質(zhì)量量標(biāo)準(zhǔn)進(jìn)行二二級(jí)質(zhì)量驗(yàn)收收工作,配合合項(xiàng)目部質(zhì)檢檢師,監(jiān)理完完成三級(jí),四四級(jí)質(zhì)量驗(yàn)收收。對(duì)工作要要一絲不茍,不不殉私情。對(duì)不能保證施工工質(zhì)量的方案案提出否決建建議,請(qǐng)有關(guān)關(guān)領(lǐng)導(dǎo)部門(mén)處處理。整理、匯總質(zhì)量量驗(yàn)收記錄。5安監(jiān)人員全面負(fù)責(zé)輸煤系系統(tǒng)水消防、噴噴霧、沖洗裝裝置安裝安裝裝工作的安全全。參加對(duì)指導(dǎo)書(shū)的的審核工作,參參加安全交底底雙簽字工作作,在工作中中認(rèn)真檢查指指導(dǎo)書(shū)的執(zhí)行行情況。深入現(xiàn)場(chǎng)施工一一線,及時(shí)發(fā)發(fā)現(xiàn)事故隱患患和不安全因因素,督促采采取防患措施施,有權(quán)責(zé)令令先停止工作作,并立即研研究處理。做好事故的調(diào)查查,分析和處處理工作。3.3作業(yè)工機(jī)機(jī)具(包括配配置、等級(jí)、精精度等)施工作業(yè)工機(jī)具具統(tǒng)計(jì)表序號(hào)機(jī)具名稱(chēng)稱(chēng)規(guī)格用途1電動(dòng)套絲機(jī)DN100套絲連接2砂輪機(jī)1.1KW切割管材3砂輪鋸φ300mm磨光4試壓泵0~4MPa電動(dòng)、手動(dòng)試壓壓5電焊機(jī)BX型焊接6手錘1.0kg、11.5kg打口7彎管器φ80mm彎管8捻鑿1#、2#、33#打口、自制序號(hào)機(jī)具名稱(chēng)稱(chēng)規(guī)格用途9液壓鑄管切割器器YZGJ-A天津塘沽機(jī)床附附件廠10空壓機(jī)6M3吹掃11套絲扳DN80mm套絲連接12管子割刀1~4#切割管材13倒鏈1t、2t、55t、提升14管鉗150~6000mm夾持管材15麻繩φ20捆綁16虎鉗15~115夾持管子直徑17鐵鍬2~4#挖溝18鐵鎬2.5~4Kgg挖溝19大錘5~8Kg挖溝20挖掘機(jī)50型挖溝21手動(dòng)葫蘆拉力器器>φ100mmm膠圈連接22熱熔式連接器與管子配套熱熔連接23活扳手100~6000mm緊固24角向磨光機(jī)φ150內(nèi)磨光25直向電動(dòng)砂輪機(jī)機(jī)φ100內(nèi)坡口其它小工具有::畫(huà)線筆、毛毛刷、板銼、鋼鋼鋸、板斧、撬撬杠等施工測(cè)量?jī)x器表表序號(hào)測(cè)量裝置名稱(chēng)規(guī)格型型號(hào)備注1水準(zhǔn)儀DSZ100、DS10測(cè)量標(biāo)高2經(jīng)緯儀J2測(cè)量角度3水平尺150~6000mm測(cè)量水平度4壓力表0~2.5Mppa、φ150水壓試驗(yàn)5鋼卷尺3m、5m、330m測(cè)量長(zhǎng)度6游標(biāo)卡尺0~300mmm、0.02mmm測(cè)量管材直徑7塞尺150A14測(cè)量膠圈接口3.4材料和設(shè)設(shè)備施工材料施工材料統(tǒng)計(jì)表表表1、室外消防防管道主要材材料匯總表序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料備注1可曲撓橡膠接頭頭DN300,PPN1.6MMpa,GJQQ(X)-DDF(Ⅱ)型個(gè)5成品2可曲撓橡膠接頭頭DN250,PPN1.6MMpa,GJQQ(X)-DDF(Ⅱ)型個(gè)2成品3鋼絲網(wǎng)骨架塑料料復(fù)合管dn315,PPN=1.66Mpa米248PE100配套電熔直接4鋼絲網(wǎng)骨架塑料料復(fù)合管dn250,PPN=1.66Mpa米186PE100配套電熔直接5鋼絲網(wǎng)骨架塑料料復(fù)合管dn160,PPN=1.66Mpa米33PE100配套電熔直接6鋼絲網(wǎng)骨架塑料料復(fù)合管dn110,PPN=1.66Mpa米228PE100配套電熔直接7電熔法蘭連接件件D315套10PE100配套PN1.66Mpa法蘭盤(pán)片配配套螺栓、螺螺母、墊片8電熔法蘭連接件件D250套4PE100配套PN1.66Mpa法蘭盤(pán)片配配套螺栓、螺螺母、墊片9電熔法蘭連接件件D160套2PE100配套PN1.66Mpa法蘭盤(pán)片配配套螺栓、螺螺母、墊片10電熔法蘭連接件件D110套12PE100配套PN1.66Mpa法蘭盤(pán)片配配套螺栓、螺螺母、墊片11電熔正三通D315個(gè)3PE10012電熔異徑三通D315×D1160個(gè)3PE10013電熔異徑三通D315×D1110個(gè)7PE10014電熔異徑三通D250×D1160個(gè)1PE10015電熔異徑三通D250×D1110個(gè)4PE100序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料備注16電熔90°彎頭頭D315個(gè)8PE10017電熔90°彎頭頭D250個(gè)2PE10018電熔90°彎頭頭D160個(gè)2PE10019電熔90°彎頭頭D110個(gè)10PE10020電熔45°彎頭頭D110個(gè)2PE10021電熔異徑直接D315×D2250個(gè)1PE10022磚砌圓形閥門(mén)井井Φ1500座7磚砌參見(jiàn)05S5002/16~25,配套重型型球墨鑄鐵支支座及鑄鐵井井蓋表2、室外消防防管道設(shè)備閥閥門(mén)匯總表序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料備注1管網(wǎng)雙法蘭蝶閥閥DN300,PPN1.6MMPa,GD3341X-116Q型個(gè)62可曲撓橡膠接頭頭DN250,PPN1.6MMpa,GD3341X-116Q型個(gè)23室外地上式消火火栓DN100,PPN1.6MMPa,SS1100/655-1.6型套6詳見(jiàn)本冊(cè)-044圖,帶座90°雙法蘭彎頭頭,DN100(與消火栓栓配套供應(yīng))表3、室外生活活污水管道主主要材料匯總總表序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料備注1高密度聚乙烯雙雙壁波紋管DN200米4HDPE雙壁波紋管環(huán)剛度≥8kNN/m22鋼絲網(wǎng)骨架塑料料復(fù)合管dn75,PNN=1.6MMpa米259PE100配套電熔直接3電熔45°彎頭頭D75個(gè)16PE1004圓形磚砌污水檢檢查井Φ700座1磚砌參見(jiàn)02S5115/195重型井蓋及蓋座座Φ700套1球墨鑄鐵參見(jiàn)97S5001-1/441、436化糞池Z1-2S型座1磚砌參見(jiàn)02S7001/13、20表4、室外工業(yè)業(yè)、生活給水水管道主要材材料匯總表序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料重量備注單重總重1鋼絲網(wǎng)骨架塑料料復(fù)合管dn160,PPN=1.66Mpa米65PE100配套電熔直接2鋼絲網(wǎng)骨架塑料料復(fù)合管dn140,PPN=1.66Mpa米79PE100配套電熔直接3鋼絲網(wǎng)骨架塑料料復(fù)合管dn50,PNN=1.6MMpa米51.5PE100配套電熔直接4內(nèi)筋嵌入式襯塑塑鋼管DN32米12.5鋼塑5內(nèi)筋嵌入式襯塑塑鋼管DN25米7鋼塑6無(wú)縫焊接鋼管D426×9..0米6420#90.555923.27無(wú)縫焊接鋼管D159×6..0米7920#22.641788.68無(wú)縫焊接鋼管D89×4.55米12620#9.381181.99無(wú)縫焊接鋼管D76×4.55米17020#7.931348.110無(wú)縫焊接鋼管D57×3.55米11620#4.62535.911無(wú)縫焊接鋼管D45×3.55米320#3.5810.712電熔法蘭連接件件D160套1PE100配套PN1.00Mpa法蘭蘭盤(pán)片配套螺螺栓、螺母、墊墊片13電熔法蘭連接件件D140套1PE100配套PN1.00Mpa法蘭蘭盤(pán)片配套螺螺栓、螺母、墊墊片14電熔法蘭連接件件D50套2PE100配套PN1.00Mpa法蘭蘭盤(pán)片配套螺螺栓、螺母、墊墊片15鋼制法蘭DN150,PPN=1.00MPa片120#6.126.1202S403配配套螺栓、螺螺母、墊片序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料重量備注單重總重16鋼制法蘭DN40,PNN=1.0MMPa片220#1.713.4202S403配配套螺栓、螺螺母、墊片17電熔異徑三通D140×D550個(gè)1PE10018異徑三通DN400×DDN80個(gè)120#GB/T124459-2000519大小頭DN80×DNN65個(gè)120#GB/T124459-2000520大小頭DN65×DNN40個(gè)120#GB/T124459-2000521大小頭DN50×DNN40個(gè)220#GB/T124459-2000522大小頭DN32×DNN25個(gè)120#GB/T124459-2000523大小頭DN25×DNN20個(gè)120#GB/T124459-2000524電熔90°彎頭頭D160個(gè)4PE10025電熔90°彎頭頭D140個(gè)4PE1002690°無(wú)縫彎頭頭DN400個(gè)220#52.510502S403//872790°無(wú)縫彎頭頭DN150個(gè)520#5.0625.302S403//872890°無(wú)縫彎頭頭DN80個(gè)620#1.126.7202S403//872990°無(wú)縫彎頭頭DN50個(gè)1020#0.343.402S403//8730鋼塑過(guò)渡接頭D50個(gè)1PE10031快速接頭Dg40個(gè)1成品表5、室外工業(yè)業(yè)、生活給水水管道設(shè)備閥閥門(mén)匯總表序號(hào)名稱(chēng)規(guī)格及型號(hào)單位數(shù)量材料備注1手動(dòng)對(duì)夾式蝶閥閥DN40,PNN=1.0MMPaWBLX-00040-110型個(gè)12流量調(diào)節(jié)閥DN150,PPN=1.00MpaLT3341X-110型個(gè)1手動(dòng)調(diào)節(jié)材料要求1)工程所使用用的主要材料料、成品、半半成品、配件件和設(shè)備必須須具有中文質(zhì)質(zhì)量合格證明明文件。2)工程所使用用的材料、設(shè)設(shè)備的規(guī)格型型號(hào)和性能檢檢測(cè)報(bào)告應(yīng)符符合國(guó)家技術(shù)術(shù)標(biāo)準(zhǔn)和設(shè)計(jì)計(jì)要求。3)所有材料進(jìn)進(jìn)入施工現(xiàn)場(chǎng)場(chǎng)時(shí)應(yīng)進(jìn)行品品種、規(guī)格、外外觀驗(yàn)收。包包裝應(yīng)完好,表表面無(wú)劃痕及及外力沖擊破破損。4)主要器具和和設(shè)備必須有有完整的安裝裝使用說(shuō)明書(shū)書(shū)。5)管道使用的的配件的壓力力等級(jí)、尺寸寸規(guī)格等應(yīng)和和管道配套。塑塑料復(fù)合管材材、管件、粘粘接劑、橡膠膠圈及其它附附件等應(yīng)是同同一廠家的配配套產(chǎn)品。6)手拉葫蘆使使用前的檢測(cè)測(cè)①檢查轉(zhuǎn)動(dòng)部部分是否靈活活,有無(wú)卡鏈鏈現(xiàn)象,鏈條條是否有裂紋紋和斷節(jié);制制動(dòng)器是否安安全可靠,銷(xiāo)銷(xiāo)子是否牢固固。②發(fā)現(xiàn)下述情況況時(shí)需要更換換零件:齒輪輪裂紋、斷齒齒、齒面磨損損搭齒厚的330%;吊鉤鉤損壞達(dá)報(bào)廢廢標(biāo)準(zhǔn)。③檢查吊掛倒倒鏈之受力構(gòu)構(gòu)件的強(qiáng)度、剛剛度是否滿足足安全要求;;牽引、吊掛掛鋼絲繩及手手扳葫蘆自身身之鋼絲繩是是否滿足要求求,有無(wú)嚴(yán)重重?cái)嘟z、斷股股及其他外觀觀壓扁、扭曲曲、嚴(yán)重腐蝕蝕等物理化學(xué)學(xué)變形。④所吊物件是是否超載。只有確確認(rèn)以上幾條條均符合安全全要求后,方方可投入使用用。3.4.3安全全器具施工安全用具統(tǒng)統(tǒng)計(jì)表序號(hào)名稱(chēng)規(guī)格單位數(shù)量備注1安全帶條152安全帽頂213工具袋個(gè)203.5工序交接接管道施工區(qū)域內(nèi)內(nèi)的地面要進(jìn)進(jìn)行清理,雜雜物、垃圾棄棄出場(chǎng)地。管管道走向上的的障礙物要清清除。在施工前應(yīng)摸清清地下高、低低壓電纜、煤煤氣等管道的的分布情況,并并作出標(biāo)記。管道敷設(shè)前,所所有組合工作作完成,臨時(shí)時(shí)吊裝措施準(zhǔn)準(zhǔn)備并制作完完畢。管道敷設(shè)前,管管溝、墊層驗(yàn)驗(yàn)收完畢。管道安裝后及時(shí)時(shí)驗(yàn)收,為下下道工序作準(zhǔn)準(zhǔn)備。4、作業(yè)程序和和方法4.1廠區(qū)室外外消防、工業(yè)業(yè)、生活給水水管道安裝施施工工序給水管材質(zhì)量要要求1)主材的技術(shù)術(shù)標(biāo)準(zhǔn)主要材料的技術(shù)術(shù)標(biāo)準(zhǔn)表序號(hào)材料名稱(chēng)質(zhì)量驗(yàn)收標(biāo)準(zhǔn)備注1鋼絲網(wǎng)骨架塑料料復(fù)合管企業(yè)標(biāo)準(zhǔn)廠家提供2HDPE雙壁波波紋管企業(yè)標(biāo)準(zhǔn)廠家提供3鍍鋅鋼管GB/T81663-198874無(wú)縫鋼管GB/T81663-198875襯塑鋼管企業(yè)標(biāo)準(zhǔn)廠家提供2)材料的驗(yàn)收收給水管材及管件件的規(guī)格品種種應(yīng)符合設(shè)計(jì)計(jì)要求,管壁壁薄厚均勻,內(nèi)內(nèi)外光滑整潔潔,不得有砂砂眼、裂紋、飛飛刺和疙瘩。管管件應(yīng)造型規(guī)規(guī)矩,尺寸合合格,并有出出廠合格證。閥門(mén)、法蘭及其其它設(shè)備應(yīng)具具有質(zhì)量合格格證,且無(wú)裂裂紋、開(kāi)關(guān)靈靈活嚴(yán)密、鑄鑄造規(guī)矩,手手輪良好。電焊條、螺栓、螺螺母等應(yīng)具有有質(zhì)量合格證證。給水管道安裝裝作業(yè)條件管溝平直,管溝溝深度、寬度度符合要求,閥閥門(mén)井、表井井墊層,消火火栓底座施工工完畢。管溝溝底夯實(shí),溝溝內(nèi)無(wú)障礙物物。且應(yīng)有防防塌方措施。管溝兩側(cè)不得堆堆放施工材料料和其它物品品。4.1.3給水水管道安裝工工藝流程1)管道安裝鋪鋪設(shè)規(guī)定廠區(qū)室外工業(yè)水水管采用無(wú)縫縫鋼管,電焊焊連接,與閥閥門(mén)法蘭連接接;室外生活活水管采用鋼鋼絲網(wǎng)骨架塑塑料復(fù)合管,電電熔連接,與與閥門(mén)法蘭連連接;規(guī)格小小于DN50的室外生活活水管采用內(nèi)內(nèi)筋嵌入式襯襯塑鋼管,卡卡環(huán)連接。鋼鋼絲網(wǎng)骨架塑塑料復(fù)合管與與襯塑鋼管之之間采用鋼塑塑轉(zhuǎn)換接頭,電電熔連接。鋼鋼絲網(wǎng)骨架塑塑料復(fù)合管與與無(wú)縫鋼管之之間采用電熔熔法蘭連接。廠區(qū)室外工業(yè)、生生活水管上的的閥門(mén)井做法法參照《室外外給水管道附附屬構(gòu)筑物》(05S502)閥門(mén)井的做法施工,閥門(mén)井應(yīng)設(shè)集水坑。根據(jù)設(shè)計(jì)坐標(biāo)和和設(shè)計(jì)布置,施施放管道埋放放溝槽線,廠廠區(qū)室外消防防給水管道采采用鋼絲網(wǎng)骨骨架塑料復(fù)合合管,電熔連連接,室內(nèi)消消防管道采用用熱浸鍍鋅管管,室外與室室內(nèi)管道接口口處通過(guò)PN1.66Mpa的法蘭與室室內(nèi)管道法蘭蘭連接。管道穿越公路等等有荷載應(yīng)設(shè)設(shè)套管,在套套管內(nèi)不得有有接口,套管管宜比管道外外徑大兩號(hào)。管道安裝和鋪設(shè)設(shè)工程中斷時(shí)時(shí),應(yīng)用木塞塞或其它蓋堵堵將管口封閉閉,防止雜物物進(jìn)入。給水管道上所采采用的閥門(mén)、管管件等其壓力力等級(jí)不應(yīng)低低于管道設(shè)計(jì)計(jì)工作壓力,且且滿足管道的的水壓試驗(yàn)壓壓力要求。在管道施工前,要要掌握管線沿沿途的地下其其它管線的布布置情況。與與相鄰管線管管線之間的水水平凈距不宜宜小于施工及及維護(hù)要求的的開(kāi)槽寬度及及設(shè)置閥門(mén)井井等附屬構(gòu)筑筑物要求的寬寬度,飲用水水管道不得敷敷設(shè)在排水管管道和污水管管道下面。2)管道敷設(shè)前前的準(zhǔn)備工作作管道鋪設(shè)應(yīng)在溝溝底標(biāo)高和管管道基礎(chǔ)檢查查合格后進(jìn)行行,在鋪設(shè)管管道前要對(duì)管管材、管件、閥閥門(mén)等作一次次外觀檢查,發(fā)發(fā)現(xiàn)有問(wèn)題的的不得使用。準(zhǔn)備好下管的機(jī)機(jī)具及繩索,并并進(jìn)行安全檢檢查。對(duì)于管管徑在1500mm以下的的金屬管道可可用撬壓繩法法下管,直徑徑大的要啟用用起重設(shè)備。管道安裝前應(yīng)用用壓縮空氣或或其它氣體吹吹掃管道內(nèi)腔腔,使管道內(nèi)內(nèi)部清潔。支敦設(shè)置支敦設(shè)置管道定位管溝驗(yàn)收管道清理管道連接(電熔連接、焊接、法蘭連接、卡環(huán)連接)試壓、沖洗、消毒管道防腐管道及閥門(mén)鋪設(shè)就位安裝準(zhǔn)備4.1.4管道道的敷設(shè)1)管道應(yīng)敷設(shè)設(shè)在原狀土地地基上或開(kāi)挖挖后經(jīng)過(guò)回填填處理達(dá)到設(shè)設(shè)計(jì)要求的回回填層上。對(duì)對(duì)高于原狀地地面的填埋試試管道,管底底的回填處理理層必須落在在達(dá)到支撐能能力的原狀土土層上。2)敷設(shè)管道時(shí)時(shí),可將管材材沿管線方向向排放在溝槽槽邊上,依次次放入溝底。為為減少地溝內(nèi)內(nèi)的操作量,對(duì)對(duì)焊接連接的的管材可在地地面上連接到到適宜下管的的長(zhǎng)度;電熔熔連接連接一一定長(zhǎng)度后用用彈性敷管法法下管。3)管道下管時(shí)時(shí),下管方法法可分為人工工下管和機(jī)械械下管、單節(jié)節(jié)下管和組合合下管等方式式。下管方法法的選擇可根根據(jù)管徑、管管長(zhǎng)和重量、管管材和接口強(qiáng)強(qiáng)度、溝槽和和現(xiàn)場(chǎng)情況及及擁有的機(jī)械械設(shè)備量等條條件確定。下下管時(shí)應(yīng)精心心操作,搬運(yùn)運(yùn)過(guò)程中應(yīng)慢慢起輕落,盡盡量不要使管管口處受力。4)管道施工中中須切割時(shí),切切割面要平直直。完成后應(yīng)應(yīng)將殘屑清除除干凈,不留留毛刺。5)管道安裝完完畢后應(yīng)按設(shè)設(shè)計(jì)要求防腐腐,如設(shè)計(jì)無(wú)無(wú)要求參照本本工藝質(zhì)量標(biāo)標(biāo)準(zhǔn)部分防腐腐。工業(yè)給水管道安安裝無(wú)縫鋼管運(yùn)至現(xiàn)現(xiàn)場(chǎng)后,首先先根據(jù)設(shè)備及及管件位置進(jìn)進(jìn)行排管,并并在現(xiàn)場(chǎng)將每每根鋼管的具具體長(zhǎng)度丈量量好,標(biāo)注具具體尺寸和排排列位置,以以便于接口時(shí)時(shí)對(duì)號(hào)入座,采采用吊車(chē)下管管,下管過(guò)程程中采用尼龍龍吊帶進(jìn)行吊吊裝,以管道道保溫層的保保護(hù)。1)修口、對(duì)口口修口集中在管道道出廠前加工工完成,為保保證焊接質(zhì)量量,焊接前均均進(jìn)行全面檢檢查、修正,使使管子端面、坡坡口角度、鈍鈍邊、圓度等等,均符合對(duì)對(duì)口接頭尺寸寸的要求,個(gè)個(gè)別鋼管需在在現(xiàn)場(chǎng)做坡口口處理時(shí),采采用氣焊切割割,清除熔渣渣后再用砂輪輪打磨平整。對(duì)口操作程序?yàn)闉椋簷z查接口接頭尺尺寸→清膛→確定并調(diào)整整鋼管縱向焊焊縫錯(cuò)開(kāi)位置置→第一次管道道找直→調(diào)整對(duì)口間間隙尺寸→對(duì)口找平→管道拉線找找直→點(diǎn)焊2)焊接接口焊接采用電電弧焊,一遍遍打底,二遍遍成活,每道道焊縫均一次次焊完,每層層施焊的引熄熄弧點(diǎn)須錯(cuò)開(kāi)開(kāi)。管節(jié)焊接前應(yīng)先先修口、清渣渣、管端端面面的坡口角度度、鈍邊、間間隙,應(yīng)符合合規(guī)范規(guī)定;;不得在對(duì)口口間隙夾焊幫幫條或用加熱熱法縮小間隙隙施焊。對(duì)口時(shí)應(yīng)使內(nèi)壁壁齊平,采用用長(zhǎng)300mm的直尺在接接口內(nèi)壁周?chē)鷩樞蛸N靠,錯(cuò)錯(cuò)口的允許偏偏查差應(yīng)為0.2倍壁厚,且且不得大于2mm。對(duì)口縱、環(huán)向焊焊縫的位置應(yīng)應(yīng)符合下列規(guī)規(guī)定:①縱向焊縫應(yīng)在在管道中心垂垂線上半圓的的45°左右處;②有加固的鋼管管,加固環(huán)的的對(duì)焊焊縫應(yīng)應(yīng)與管節(jié)縱向向焊縫錯(cuò)開(kāi),其其間距不應(yīng)小小于100mm;加固環(huán)距距管節(jié)的環(huán)向向焊縫不應(yīng)小小于50mm;③管道任何位置置不得有十字字形焊縫。定位焊時(shí),定位位焊縫所有焊焊條號(hào)(或牌號(hào))應(yīng)與正式焊焊接相同,但但焊條直徑可可選細(xì)一些。定定位焊縫的焊焊接電流要選選得比正式焊焊接時(shí)大一些些,通常大10%-15%,以保證焊焊透。管道的焊接:焊焊縫質(zhì)量必須須符合GB502268-977中4.2的有關(guān)規(guī)定定,焊縫應(yīng)平平滑,寬窄一一致,根部焊焊透,無(wú)明顯顯的凹凸缺陷陷及咬邊現(xiàn)象象,焊縫加強(qiáng)強(qiáng)面應(yīng)高出管管面約2毫米,焊出出坡口邊緣2-3毫米。管道與法蘭焊接接時(shí),管道應(yīng)應(yīng)插入法蘭三三分之二,法法蘭與管道應(yīng)應(yīng)垂直,兩者者的軸線重合合。①水平管道坡度度不小于0.3%。②焊接前應(yīng)檢查查施焊環(huán)境,焊焊接安裝設(shè)備備、焊接材料料的干燥及清清理,必須符符合規(guī)范及焊焊接操作規(guī)定定。③焊接雙面焊件件時(shí),應(yīng)清理理并檢查焊縫縫根部背面,清清理缺陷后,方方可施焊背面面焊縫。規(guī)定定清根的焊縫縫應(yīng)在清根后后進(jìn)行外觀檢檢查后方可施施焊。④管壁大于4mmm的管道焊接接前必須打坡坡口,坡口表表面不得有夾夾層、裂縫、加加工損傷、毛毛刺及焰切割割熔渣等缺陷陷。焊接后藥藥皮應(yīng)敲干凈凈,焊口應(yīng)呈呈現(xiàn)均勻的魚(yú)魚(yú)鱗狀,不得得有氣孔、夾夾渣、裂紋、焊焊瘤等現(xiàn)象,咬咬肉長(zhǎng)度應(yīng)在在規(guī)范要求內(nèi)內(nèi)。大于20mm的的放氣閥門(mén)采采用法蘭連接接,小于或等等于20mm的放氣閥門(mén)門(mén)采用螺紋連連接。管道轉(zhuǎn)彎、穿墻墻及支吊架處處,不應(yīng)有接接口和焊縫,管管道穿越墻壁壁應(yīng)預(yù)埋套管管,套管直徑徑應(yīng)比管道保保溫外徑大50mm。管道最高高點(diǎn)設(shè)放氣閥閥,最低點(diǎn)設(shè)設(shè)放水閥。4.1.6閥閥門(mén)的安裝1)閥門(mén)安裝前前應(yīng)核對(duì)閥門(mén)門(mén)的規(guī)格型號(hào)號(hào)和檢查閥門(mén)門(mén)的外觀質(zhì)量量。2)閥門(mén)安裝前前應(yīng)作強(qiáng)度和和嚴(yán)密性試驗(yàn)驗(yàn)。試驗(yàn)應(yīng)在在每批(同牌牌號(hào)、同型號(hào)號(hào)、同規(guī)格)數(shù)數(shù)量中抽查110%,且不不應(yīng)少于一個(gè)個(gè)。對(duì)于安裝裝在主干管上上起切斷作用用的閉路閥門(mén)門(mén),應(yīng)逐個(gè)作作強(qiáng)度和嚴(yán)密密性試驗(yàn)。閥閥門(mén)試壓宜在在專(zhuān)用的試壓壓臺(tái)上進(jìn)行。3)閥門(mén)的強(qiáng)度度和嚴(yán)密性試試驗(yàn),應(yīng)符合合下列規(guī)定::閥門(mén)的強(qiáng)度度試驗(yàn)壓力為為工稱(chēng)壓力的的1.5倍;;嚴(yán)密性試驗(yàn)驗(yàn)壓力為公稱(chēng)稱(chēng)壓力的1..1倍;試試驗(yàn)壓力在試試驗(yàn)持續(xù)時(shí)間間內(nèi)應(yīng)保持不不變,且殼體體填料及閥瓣瓣密封面無(wú)滲滲漏。閥門(mén)試試壓的試驗(yàn)持持續(xù)時(shí)間不應(yīng)應(yīng)少于下表的的規(guī)定。閥門(mén)試驗(yàn)持續(xù)時(shí)時(shí)間公稱(chēng)直徑DN(mm)最短試驗(yàn)持續(xù)時(shí)時(shí)間(s)嚴(yán)密性試驗(yàn)強(qiáng)度試驗(yàn)金屬密封非金屬密封≤5015151565~200301560250~450060301804)閥門(mén)法蘭的的襯墊不得凸凸入管內(nèi),其其外邊緣接近近螺栓孔為宜宜,不得安裝裝雙墊或偏墊墊。5)連接法蘭的的螺栓,直徑徑和長(zhǎng)度應(yīng)符符合標(biāo)準(zhǔn),擰擰緊后,突出出螺母的長(zhǎng)度度不應(yīng)大于螺螺桿直徑的11/2。4.1.7管道道水壓試驗(yàn)及及消毒1)一般規(guī)定(1)水壓試驗(yàn)驗(yàn)應(yīng)在回填土土前進(jìn)行。(2)水壓試驗(yàn)驗(yàn)前,對(duì)試壓壓管段應(yīng)采取取有效的固定定和保護(hù)措施施,但接頭部部位必須明露露。(3)水壓試驗(yàn)驗(yàn)管段長(zhǎng)度一一般不要超過(guò)過(guò)1000mm,超過(guò)長(zhǎng)度度宜分段試壓壓,并應(yīng)在管管件支敦達(dá)到到強(qiáng)度后方可可進(jìn)行。(4)試壓管段段不得采用閘閘閥做堵板,不不得與消火栓栓等附件相連連,已設(shè)置這這類(lèi)附件的要要設(shè)置堵板,各各類(lèi)閥門(mén)在試試壓過(guò)程中要要全部處于開(kāi)開(kāi)啟狀態(tài)。(5)管道水壓壓試驗(yàn)前后要要做好水源引引進(jìn)及排水疏疏導(dǎo)路線的設(shè)設(shè)計(jì)。(6)管道灌水水應(yīng)從下游緩緩慢灌入。灌灌入時(shí),在試試驗(yàn)管段的上上游管頂及管管段中的凸起起點(diǎn)應(yīng)設(shè)排氣氣閥將管道內(nèi)內(nèi)的氣體排除除。(7)水壓試驗(yàn)驗(yàn)的壓力表應(yīng)應(yīng)校正,彈簧簧壓力計(jì)的精精度不應(yīng)低于于1.5級(jí),最最大量程宜為為試驗(yàn)壓力的的1.3~1.5倍,表表殼的公稱(chēng)直直徑不應(yīng)小于于150mmm,壓力表至至少要有兩塊塊。2)試壓及消毒毒程序如下(1)按本標(biāo)準(zhǔn)準(zhǔn)有關(guān)工藝鋪鋪設(shè)連接試驗(yàn)驗(yàn)管道,進(jìn)水水管段,安裝裝閥門(mén)、試壓壓泵、壓力表表等。(2)緩慢充水水,沖水后應(yīng)應(yīng)把管內(nèi)空氣氣全部排盡。(3)空氣排盡盡后,將檢查查閥門(mén)關(guān)閉好好,進(jìn)行加緩緩慢加壓,先先升至工作壓壓力檢查,再再升至試壓壓壓力觀察,然然后降至工作作壓力讀表,符符合本標(biāo)準(zhǔn)質(zhì)質(zhì)量標(biāo)準(zhǔn)為合合格。(4)升壓過(guò)程程中,若發(fā)現(xiàn)現(xiàn)彈簧壓力計(jì)計(jì)表針擺動(dòng)、不不穩(wěn)、且升壓壓緩慢則氣體體沒(méi)排盡,應(yīng)應(yīng)重新排氣后后再升壓。(5)試壓過(guò)程程中,全部檢檢查若發(fā)現(xiàn)接接口滲漏,應(yīng)應(yīng)作出明顯標(biāo)標(biāo)記,待壓力力降至零后,制制定修補(bǔ)措施施全面修補(bǔ),再再重新試驗(yàn),直直至合格。(6)試驗(yàn)合格格后,進(jìn)行沖沖洗,沖洗合合格后,應(yīng)立立即辦理驗(yàn)收收手續(xù),組織織回填。(7)新建室外外給水管道于于室內(nèi)管道連連接前,應(yīng)經(jīng)經(jīng)室內(nèi)外全部部沖洗合格后后方可連接。(8)沖洗標(biāo)準(zhǔn)準(zhǔn)當(dāng)設(shè)計(jì)無(wú)規(guī)規(guī)定時(shí),以出出口的水色和和透明度與入入口處的進(jìn)水水目測(cè)一致為為合格。(9)飲用水管管道在使用前前的消毒用每每升水含200~30mg的游游離氯的清水水灌滿后消毒毒。含氯水在在管道中應(yīng)靜靜置24h以上,消毒毒后再用水沖沖洗。常用的的消毒劑為漂漂白粉,進(jìn)行行消毒處理時(shí)時(shí),把漂白粉粉放入水桶內(nèi)內(nèi),加水?dāng)嚢璋枞芙?,隨同同管道充水一一起加入管段段,浸泡244小時(shí)后,放放水沖洗。新新安裝的飲用用水管道可采采用下表選用用劑量。每100m管道道消毒用水量量及漂白粉用用量表管徑DN(mmm)15~5075100150200250300350400用水量(m3)0.8~568142232425675漂白粉用量(kkg)0.090.110.140.140.380.550.930.971.34.1.8室外外消火栓安裝裝1)室外消火栓栓質(zhì)量要求室外消火栓、閥閥門(mén)等產(chǎn)品型型號(hào)的選用應(yīng)應(yīng)遵守設(shè)計(jì)要要求。嚴(yán)格檢查消火栓栓各處開(kāi)關(guān)是是否靈活、嚴(yán)嚴(yán)密、吻合,所所配帶的附屬屬設(shè)備配件是是否齊全。產(chǎn)品要具有生產(chǎn)產(chǎn)合格證和消消防主管部門(mén)門(mén)的認(rèn)可證書(shū)書(shū)2)室外消火栓栓安裝工藝流流程水壓試驗(yàn)水壓試驗(yàn)安裝支管砌筑支敦連接管道防腐安裝消火栓管道穿井壁空隙的處理檢查消火栓等設(shè)備3)室外消火栓栓安裝操作工工藝室外消防火栓所所有外露消防防設(shè)施,均應(yīng)應(yīng)按規(guī)定油漆漆紅色。其消消防火栓的安安裝栓體支墩墩不要放在回回填土上,室室外消火栓距距路邊不應(yīng)大大于2m,如大于2m,則消火栓與管管之間加彎頭頭連接,以保保證消防栓與與路邊的距離離滿足要求,且且消防栓底部部應(yīng)設(shè)支墩。室外消火栓的安裝應(yīng)參照標(biāo)準(zhǔn)圖01S201、99S203。廠區(qū)室外消防給給水管道上的的閥門(mén)井做法法可參照(05S5002)閥門(mén)井的的做法施工,閥閥門(mén)井應(yīng)設(shè)集集水坑。埋入土中的管道道防腐按圖紙紙?jiān)O(shè)計(jì)要求,法法蘭接口涂瀝瀝青冷底子油油及瀝青漆各各兩道,并用用瀝青麻布或或0.2mmm厚底塑料薄薄膜包嚴(yán)。消火栓的水壓試試驗(yàn)和沖洗參參照與管網(wǎng)水水壓試驗(yàn)和沖沖洗。4.1.9埋埋地鋼管的防防腐1)防護(hù)層施工工環(huán)境應(yīng)在膠粘帶制造造商提供的說(shuō)說(shuō)明書(shū)推薦的的環(huán)境條件下下進(jìn)行,施工工時(shí)的溫度應(yīng)應(yīng)高于露點(diǎn)溫溫度3℃以上,在風(fēng)風(fēng)沙較大、雨雨雪天氣時(shí),沒(méi)沒(méi)有可靠的防防護(hù)措施,不不應(yīng)進(jìn)行現(xiàn)場(chǎng)場(chǎng)施工。2)鋼管表面預(yù)預(yù)處理鋼管表面除銹前前,應(yīng)清除鋼鋼管表面的焊焊渣、毛刺,并并用適當(dāng)?shù)姆椒椒▽⒏街谠阡摴芡獗砻婷娴挠?、油脂脂及任何其它它雜質(zhì)清除干干凈。鋼管表面除銹宜宜采用噴(拋拋)射除銹方方式。受現(xiàn)場(chǎng)場(chǎng)施工條件限限制時(shí),經(jīng)設(shè)設(shè)計(jì)選定,可可采用動(dòng)力工工具除銹方法法。采用噴(拋拋)射除銹時(shí)時(shí),其質(zhì)量應(yīng)應(yīng)達(dá)到《涂裝裝前鋼材表面面銹蝕等級(jí)和和除銹等級(jí)》GB/T88923規(guī)定的Sa2.5級(jí);采用電電動(dòng)工具除銹銹方法時(shí),除除銹等級(jí)達(dá)到到St3級(jí)。除銹后,對(duì)可能能刺傷防腐層層的尖銳部分分應(yīng)進(jìn)行打磨磨。并將附著著在金屬表面面的磨料和灰灰塵清除干凈凈。鋼管表面預(yù)處理理后至涂底漆漆前的時(shí)間間間隔宜控制在在4h內(nèi),期間應(yīng)應(yīng)防止鋼管表表面受潮和污污染。涂底漆漆前,如出現(xiàn)現(xiàn)返銹或表面面污染時(shí),必必須重新進(jìn)行行表面預(yù)處理理。3)底漆涂敷使用前,底漆應(yīng)應(yīng)充分?jǐn)嚢杈鶆颉0凑罩圃焐烫峁┕┑牡灼嵴f(shuō)明明書(shū)的要求涂涂刷底漆。底底漆應(yīng)涂刷均均勻,不得有有漏涂、凝塊塊和流掛等缺缺陷。待底漆表干后再再纏繞膠粘帶帶,期間應(yīng)防防止表面污染染。4)膠粘帶纏繞繞膠粘帶的解卷溫溫度應(yīng)滿足膠膠粘帶制造商商規(guī)定的溫度度。宜使用專(zhuān)專(zhuān)用纏繞機(jī)或或手動(dòng)纏繞機(jī)機(jī)進(jìn)行纏繞施施工。在纏繞繞時(shí),如焊縫縫兩側(cè)可能產(chǎn)產(chǎn)生空隙,應(yīng)應(yīng)采用膠粘帶帶制造商配套套供應(yīng)的填料料填充焊縫兩兩側(cè)。螺旋焊焊縫管纏繞膠膠粘帶時(shí),纏纏繞方向應(yīng)與與焊縫方向一一致。按預(yù)先選定的工工藝,在涂好好底漆的鋼管管上按照搭接接要求纏繞,膠膠粘帶始末搭搭接長(zhǎng)度應(yīng)不不小于1/4管子周長(zhǎng),且且不少于100mm。兩次纏繞繞搭接縫應(yīng)相相互錯(cuò)開(kāi)。搭搭接寬度遵照照設(shè)計(jì)規(guī)定,但但不應(yīng)低于25mm。纏繞時(shí)搭搭接縫應(yīng)平行行,不得扭曲曲皺褶,帶端端應(yīng)壓貼,使使其不翹起。工廠預(yù)制聚乙烯烯膠粘帶防腐腐層,管端應(yīng)應(yīng)有150mmm±10mmm的焊接預(yù)留留段。防腐管管應(yīng)按照SY/T00414-22007第7章的要求進(jìn)進(jìn)行質(zhì)量檢驗(yàn)驗(yàn),檢驗(yàn)合格格后方可出廠廠。5)預(yù)制防腐管管的標(biāo)志、堆堆放和運(yùn)輸合格的防腐管在在距管端約1m處作出標(biāo)志志,標(biāo)明鋼管管規(guī)格、材質(zhì)質(zhì)、防腐層類(lèi)類(lèi)型、等級(jí)、涂涂敷商名稱(chēng)、生生產(chǎn)日期和執(zhí)執(zhí)行標(biāo)準(zhǔn)等。防腐層吊架應(yīng)采采用寬尼龍帶帶或?qū)S玫蹙呔?,不能用損損傷防腐層的的吊具。采用用合理的吊裝裝方法,輕吊吊輕放,嚴(yán)禁禁損傷防腐層層。運(yùn)輸時(shí)應(yīng)采取相相應(yīng)的防護(hù)措措施防止損傷傷防腐層。6)補(bǔ)傷及補(bǔ)口口修補(bǔ)時(shí)先修整損損傷部位,并并清理干凈,涂涂上底漆。使用與管體相同同的膠粘帶修修補(bǔ)時(shí),宜采采用纏繞法;;也可使用專(zhuān)專(zhuān)用膠粘帶采采用貼補(bǔ)法修修補(bǔ)。纏繞和和貼補(bǔ)寬度應(yīng)應(yīng)超出損傷邊邊緣至少50mm。使用與管體相同同的膠粘帶修修補(bǔ)時(shí),防腐腐層結(jié)構(gòu)、等等級(jí)應(yīng)與管體體相同;采用用專(zhuān)用補(bǔ)傷帶帶時(shí),其防腐腐層性能應(yīng)不不低于管體防防腐層。補(bǔ)口帶與原防腐腐層搭接寬度度應(yīng)不小于100mm。補(bǔ)口處防防腐等級(jí)應(yīng)不不低于管體防防腐層。4.2廠區(qū)室外外生活污水管管道安裝施工工工序生活污水管材質(zhì)質(zhì)量要求1)顏色應(yīng)均勻勻一致,無(wú)色色澤不均及分分解變色線;;2)內(nèi)壁光滑、平平整、無(wú)氣泡泡、裂口、脫脫皮、嚴(yán)重的的冷斑及明顯顯的裂紋、凹凹陷;3)管材軸向不不得有異向彎彎曲,其直線線度偏差應(yīng)小小于1%,端口必必須平直其垂垂直于軸線;;4)管件應(yīng)完整整無(wú)損,無(wú)變變形、合??p縫、澆口應(yīng)平平整無(wú)開(kāi)裂;;5)管材、管件件的承插口工工作面應(yīng)平整整、尺寸準(zhǔn)確確,以保證接接口的密封性性能。生活污水管道道安裝作業(yè)條條件管溝平直,管溝溝深度、寬度度符合要求,閥閥門(mén)井、表井井墊層,消火火栓底座施工工完畢。管溝溝底夯實(shí),溝溝內(nèi)無(wú)障礙物物。且應(yīng)有防防塌方措施。管溝兩側(cè)不得堆堆放施工材料料和其它物品品。4.2.3生生活污水管道道安裝工藝流流程下管檢驗(yàn)下管機(jī)具和繩索檢查溝底標(biāo)高和管基強(qiáng)度接口閉水實(shí)驗(yàn)下管前管材檢驗(yàn)下管檢驗(yàn)下管機(jī)具和繩索檢查溝底標(biāo)高和管基強(qiáng)度接口閉水實(shí)驗(yàn)下管前管材檢驗(yàn)1)管道安裝鋪鋪設(shè)規(guī)定廠區(qū)室外生活污污水管道系統(tǒng)統(tǒng)采用重力流流與壓力流管管道相結(jié)合的的管道系統(tǒng),重重力流管道采采用HDPE雙壁波紋管管(接室內(nèi)排排水支管為PVC-U管),承插插彈性密封連連接(PVC-U管溶劑粘接接),壓力流流污水管采用用鋼絲網(wǎng)骨架架塑料復(fù)合管管,電熔連接接?;S池的做法及及安裝參見(jiàn)標(biāo)標(biāo)準(zhǔn)圖集《磚磚砌化糞池》(02S701)。廠區(qū)室外重力流流污水管道檢檢查井均采用用磚砌圓形檢檢查井,施工工參照標(biāo)準(zhǔn)圖圖集《排水檢檢查井》(02S5115)。廠區(qū)室外重力流流污水管道檢檢查井的井頂頂面標(biāo)高與所所在位置的場(chǎng)場(chǎng)地標(biāo)高一致致,井中采用用流槽連接,其其銜接方式原原則上采用管管頂平接,當(dāng)當(dāng)檢查井的進(jìn)進(jìn)出管管徑相相等時(shí),所注注標(biāo)高為檢查查井中心流槽槽底面標(biāo)高;;當(dāng)進(jìn)出管管管徑不同時(shí),則則所注標(biāo)高分分別為進(jìn)出水水管口的內(nèi)底底面標(biāo)高。對(duì)于鋼絲網(wǎng)骨架架塑料復(fù)合管管的管道連接接,由生產(chǎn)廠廠家提供技術(shù)術(shù)條件。2)閉水試驗(yàn)管道應(yīng)于充滿水水24h后進(jìn)進(jìn)行嚴(yán)密性檢檢查,水位應(yīng)應(yīng)高于檢查管管段上游端部部的管頂。如如地下水位高高出管頂時(shí),則則應(yīng)高出地下下水位。一般般采用外觀檢檢查,檢查中中應(yīng)補(bǔ)水,水水位保持規(guī)定定值不變,無(wú)無(wú)漏水現(xiàn)象則則認(rèn)為合格。4.3管溝施施工4.3.1管道道開(kāi)挖與回填填施工要求溝槽開(kāi)挖:開(kāi)挖挖溝槽設(shè)管道道的溝底標(biāo)高高,必須符合合設(shè)計(jì)要求,清清除堆積在溝溝槽的回填土土,準(zhǔn)確的將將地基整平至至規(guī)定標(biāo)準(zhǔn);;凹凸度必須須小于+50、-100mmm;個(gè)別地方方的超挖,應(yīng)應(yīng)用碎石和砂砂填補(bǔ)夯實(shí)。管管道施放須與與溝槽底開(kāi)挖挖線間凈距及及并排敷設(shè)管管壁間凈距必必須符合圖紙紙要求。管道的回填:為為了保證管道道外壁與周?chē)鷩寥懒己媒咏佑|,提高管管道承載能力力和安全運(yùn)行行,管道敷設(shè)設(shè)完并檢查后后,對(duì)溝槽內(nèi)內(nèi)回填土要嚴(yán)嚴(yán)格要求。回回填土料以輕輕亞粘土,不不得用粉砂、細(xì)細(xì)沙、淤泥、石石塊、磚塊凍凍土等,當(dāng)填填土?xí)r,不允允許用堅(jiān)硬的的純粘土回填填夯實(shí),回填填必須在管道道兩側(cè)同時(shí)分分層進(jìn)行,并并逐層夯實(shí),每每層回填土厚厚度為20~30厘米。管溝開(kāi)挖工藝流流程測(cè)量放線定位釘中心樁管溝回填測(cè)量放線定位釘中心樁管溝回填確定線路管溝開(kāi)挖(1)測(cè)量、定定位測(cè)量之前先找固固定好水準(zhǔn)點(diǎn)點(diǎn),并沿管道道線路設(shè)置臨臨時(shí)水準(zhǔn)點(diǎn)。測(cè)量管線中心線線和轉(zhuǎn)彎處的的角度,并與與當(dāng)?shù)毓潭ńńㄖ锵噙B。給水管道坐標(biāo)和和標(biāo)高偏差要要符合本標(biāo)準(zhǔn)準(zhǔn)的規(guī)定,從從測(cè)量定位起起就應(yīng)控制偏偏差值符合偏偏差要求。(2)溝槽開(kāi)挖挖按設(shè)計(jì)圖紙要求求及測(cè)量定位位的中心線,依依據(jù)溝槽開(kāi)挖挖計(jì)算尺寸,撒撒好灰線。挖掘管溝和檢查查井底槽時(shí),溝溝底留出155~20cm暫不不開(kāi)挖。待下下道工序進(jìn)行行前抄平開(kāi)挖挖,如個(gè)別地地方不慎破壞壞了天然土層層,要先清除除松動(dòng)土壤,用用砂等填至標(biāo)標(biāo)高,夯實(shí)。當(dāng)遇到有地下水水時(shí),排水或或人工抽水應(yīng)應(yīng)保證下道工工序進(jìn)行前將將水排除。敷設(shè)管道前,應(yīng)應(yīng)按規(guī)定進(jìn)行行排尺,并將將溝底清理到到設(shè)計(jì)標(biāo)高。采用機(jī)械挖溝時(shí)時(shí),應(yīng)由專(zhuān)人人指揮。為確確保機(jī)械挖溝溝時(shí)溝底的土土層不被擾動(dòng)動(dòng)和破壞,用用機(jī)械挖溝時(shí)時(shí),當(dāng)天不能能下管時(shí),溝溝底應(yīng)留出00.2m左右右一層不挖,待待鋪管前人工工清挖。(3)回填管道安裝驗(yàn)收合合格后應(yīng)立即即回填?;靥顣r(shí)溝槽內(nèi)應(yīng)應(yīng)無(wú)積水,不不得帶水回填填,不得回填填淤泥、有機(jī)機(jī)物及凍土。回回填土中不得得含有石塊、磚磚及其它雜硬硬物體。管道兩側(cè)及管頂頂以上0.55m部分的回回填,應(yīng)同時(shí)時(shí)從管道兩側(cè)側(cè)填土分層夯夯實(shí),不得損損壞管子和防防腐層,溝槽槽其余部分的的回填也應(yīng)分分層夯實(shí)。管管子接口工作作坑的回填必必須仔細(xì)夯實(shí)實(shí)。管道回填宜在管管道充滿水的的情況下進(jìn)行行,管道敷設(shè)設(shè)后不宜長(zhǎng)期期處于空管狀狀態(tài)。4.4質(zhì)量控控制計(jì)劃按《機(jī)械設(shè)備安安裝工程標(biāo)準(zhǔn)準(zhǔn)及驗(yàn)收規(guī)范范》4.4.1給給水管道安裝裝質(zhì)量標(biāo)準(zhǔn)1)一般規(guī)定室外消防、工業(yè)業(yè)、生活給水水管道采用鋼鋼絲網(wǎng)骨架塑塑料復(fù)合管、鍍鍍鋅鋼管、無(wú)無(wú)縫鋼管、襯襯塑鋼管,其其管材、管件件應(yīng)是同一廠廠家的配套產(chǎn)產(chǎn)品。2)主控項(xiàng)目(1)管道的接接口法蘭、卡卡口、卡箍等等應(yīng)安裝在檢檢查井或地溝溝內(nèi),不應(yīng)埋埋在土壤中。檢檢驗(yàn)方法:觀觀察檢查(2)管網(wǎng)必須須進(jìn)行水壓試試驗(yàn),試驗(yàn)壓壓力為工作壓壓力的1.55倍。檢驗(yàn)方法:管材材為鋼管時(shí),試試驗(yàn)壓力下110min內(nèi)內(nèi)的壓力降不不應(yīng)大于0..05Mpaa,然后降至至工作壓力進(jìn)進(jìn)行檢查,壓壓力應(yīng)保持不不變,不滲不不漏;管材為為塑料復(fù)合管管時(shí),試驗(yàn)壓壓力下,穩(wěn)壓壓1h壓力降降不大于0..05Mpaa,然后降至至工作壓力進(jìn)進(jìn)行檢查,壓壓力應(yīng)保持不不變,不滲不不漏。(3)鍍鋅鋼管管、鋼管的埋埋地防腐必須須符合設(shè)計(jì)要要求,如設(shè)計(jì)計(jì)無(wú)規(guī)定時(shí),可可按表《管道道防腐層種類(lèi)類(lèi)》的規(guī)定執(zhí)執(zhí)行。檢驗(yàn)方法:觀察察和切開(kāi)防腐腐層檢查。(5)給水管道道在竣工后,必必須對(duì)管道進(jìn)進(jìn)行沖洗,飲飲用水管道還還要在沖洗后后進(jìn)行消毒,滿滿足飲用水衛(wèi)衛(wèi)生要求。檢驗(yàn)方法:觀察察沖洗水的濁濁度,查看有有關(guān)部門(mén)提供供的檢驗(yàn)報(bào)告告。3)一般項(xiàng)目(1)管道的坐坐標(biāo)、標(biāo)高、坡坡度應(yīng)符合設(shè)設(shè)計(jì)要求,管管道安裝的允允許偏差應(yīng)符符合表《室外外給水管道安安裝的允許偏偏差和檢驗(yàn)方方法》的規(guī)定定。(2)管道連接接應(yīng)符合工藝藝要求,閥門(mén)門(mén)安裝的位置置應(yīng)正確。檢驗(yàn)方法:現(xiàn)場(chǎng)場(chǎng)觀察檢查。(3)給水管道道與污水管道道在不同標(biāo)高高平行敷設(shè),其其垂直間距在在500mmm以內(nèi)時(shí),給給水管管徑小小于或等于2200mm的的,管壁水平平間距不得小小于1.5mm;管徑大于于200mmm的,不得小小于3m。檢驗(yàn)方方法:觀察和和尺量檢查室外給水管道安安裝的允許偏偏差和檢驗(yàn)方方法項(xiàng)次項(xiàng)目允許偏差(mm)檢驗(yàn)方法1坐標(biāo)鑄鐵管埋地100拉線和尺量檢查敷設(shè)在溝槽內(nèi)50鋼管、塑料管、復(fù)復(fù)合管埋地100敷設(shè)在溝槽內(nèi)或或架空402標(biāo)高鑄鐵管埋地±50拉線和尺量檢查敷設(shè)在溝槽內(nèi)±30鋼管、塑料管、復(fù)復(fù)合管埋地±50敷設(shè)在溝槽內(nèi)或或架空±303水平管縱橫向彎曲鑄鐵管埋地40拉線和尺量檢查敷設(shè)在溝槽內(nèi)鋼管、塑料管、復(fù)復(fù)合管埋地30敷設(shè)在溝槽內(nèi)或或架空4)成品保護(hù)給水管道、管件件、閥門(mén)及消消火栓運(yùn)、放放要避免碰撞撞損傷。消火栓并及表井井要及時(shí)砌好好,以保證管管件安裝后不不受損壞。埋地管要避免受受外荷載破壞壞而產(chǎn)生變形形,試水完畢畢后要及時(shí)泄泄水,防止受受凍。管道穿公路基礎(chǔ)礎(chǔ)要加套管。地下管道回填土土?xí)r,為防止止管道中心線線位移或損壞壞管道,應(yīng)用用人工先在管管子周?chē)钔镣梁粚?shí),并應(yīng)應(yīng)在管道兩邊邊同時(shí)進(jìn)行,直直至管頂0..5m以上時(shí)時(shí),在不損壞壞管道的情況況下,方可采采用蛙式打夯夯稅夯實(shí)。在管道安裝過(guò)程程中,管道未未捻口前應(yīng)對(duì)對(duì)接口處做臨臨時(shí)封堵,以以免污物進(jìn)入入管道。無(wú)縫鋼管焊接時(shí)時(shí)應(yīng)注意不要要在管道外壁壁面起弧,應(yīng)應(yīng)在坡口內(nèi)起起弧。以免擦擦傷,影響外外觀。不在現(xiàn)場(chǎng)組裝的的管段在運(yùn)輸輸過(guò)程中應(yīng)防防止擦傷,在在現(xiàn)場(chǎng)組裝的的管段,組裝裝后應(yīng)堆放在在有防護(hù)或遮遮蓋的場(chǎng)地,以以防銹蝕。焊后應(yīng)按要求做做防銹及保溫溫處理。4.4.2室外外消火栓安裝裝質(zhì)量標(biāo)準(zhǔn)1)一般規(guī)定室外消火栓的安安裝位置、形形式必須符合合設(shè)計(jì)要求。2)主控項(xiàng)目系統(tǒng)必須進(jìn)行水水壓試驗(yàn),在在試驗(yàn)壓力下下,10miin內(nèi)壓力力降不大于00.05Mppa,然后降降至工作壓力力進(jìn)行檢查,壓壓力保持不變變,不滲不漏漏。消防管道在竣工工前,必須對(duì)對(duì)管道進(jìn)行沖沖洗。檢驗(yàn)方法:觀察察沖洗出水的的濁度。消火栓的位置標(biāo)標(biāo)志應(yīng)明顯,栓栓口的位置應(yīng)應(yīng)方便操作。檢驗(yàn)方法:觀察察和尺量檢查查。3)一般項(xiàng)目室外消火栓的各各項(xiàng)安裝尺寸寸應(yīng)符合設(shè)計(jì)計(jì)要求,栓口口安裝高度允允許偏差未±20mm。檢驗(yàn)方法:尺量量檢查。4)成品保護(hù)定位控制樁,挖挖好的溝槽等等均應(yīng)有保護(hù)護(hù)措施給水管道敷設(shè)完完畢,管溝回回填之前,應(yīng)應(yīng)由保護(hù)措施施,以免管道道受破壞。冬季施工水壓試試驗(yàn)應(yīng)由保護(hù)護(hù)措施,試壓壓完畢后應(yīng)排排盡水,以免免管道凍裂。消火栓、消防水水泵接合器等等安裝完畢交交工之前施工工現(xiàn)場(chǎng)應(yīng)由保保護(hù)措施。4.4.3生活活污水管道安安裝質(zhì)量標(biāo)準(zhǔn)準(zhǔn)1)一般規(guī)定室外生活污水管管道采用鋼絲絲網(wǎng)骨架塑料料復(fù)合管和HDPE雙壁波紋管管。其規(guī)格及及質(zhì)量必須符符合現(xiàn)行國(guó)家家標(biāo)準(zhǔn)及設(shè)計(jì)計(jì)要求。2)主控項(xiàng)目排水管道的坡度度必須符合設(shè)設(shè)計(jì)要求,嚴(yán)嚴(yán)禁無(wú)坡和倒倒坡。管道埋設(shè)前必須須做灌水實(shí)驗(yàn)驗(yàn)和通水試驗(yàn)驗(yàn),排水應(yīng)通通暢,無(wú)堵塞塞,管接口無(wú)無(wú)滲漏。3)一般項(xiàng)目管道的坐標(biāo)和標(biāo)標(biāo)高應(yīng)符合設(shè)設(shè)計(jì)要求,安安裝的允許偏偏差應(yīng)符合下下表的規(guī)定。室外排水管道的的安裝的允許許偏差和檢驗(yàn)驗(yàn)辦法項(xiàng)次項(xiàng)目次允許偏差(mmm)項(xiàng)檢驗(yàn)方法1坐標(biāo)埋地100拉線尺量敷設(shè)在溝槽內(nèi)502標(biāo)高埋地±20用水平儀、拉線和尺量敷設(shè)在溝槽內(nèi)±204)成品保護(hù)污水管道、管件件、閥門(mén)運(yùn)、放放要避免碰撞撞損傷。閥門(mén)井要及時(shí)砌砌好,以保證證管件安裝后后不受損壞。埋地管要避免受受外荷載破壞壞而產(chǎn)生變形形。管道穿公路基礎(chǔ)礎(chǔ)要加套管。地下管道回填土土?xí)r,為防止止管道中心線線位移或損壞壞管道,應(yīng)用用人工先在管管子周?chē)钔镣梁粚?shí),并應(yīng)應(yīng)在管道兩邊邊同時(shí)進(jìn)行,直直至管頂0..5m以上時(shí)時(shí),在不損壞壞管道的情況況下,方可采采用蛙式打夯夯稅夯實(shí)。在管道安裝過(guò)程程中,管道未未捻口前應(yīng)對(duì)對(duì)接口處做臨臨時(shí)封堵,以以免污物進(jìn)入入管道。4.4.4管溝溝施工質(zhì)量標(biāo)標(biāo)準(zhǔn)1)一般規(guī)定冬季井室施工應(yīng)應(yīng)有防凍措施施,夏季施工工應(yīng)有防曬措措施。2)主控項(xiàng)目管溝的基層處理理和井室的地地基必須符合合設(shè)計(jì)要求。檢驗(yàn)方法:現(xiàn)場(chǎng)場(chǎng)觀察檢查。各類(lèi)井室的井蓋蓋應(yīng)符合設(shè)計(jì)計(jì)要求,應(yīng)有有明顯的文字字標(biāo)識(shí),各種種井蓋不得混混用。檢驗(yàn)方法:現(xiàn)場(chǎng)場(chǎng)觀察檢查。重型鑄鐵或混凝凝土井圈,不不得直接放在在井室的磚墻墻上,磚墻上上應(yīng)做不少于于80mm厚的的細(xì)石混凝土土。檢驗(yàn)方法:觀察察和尺量檢查查。3)一般項(xiàng)目管溝的坐標(biāo)、位位置、溝底標(biāo)標(biāo)高應(yīng)符合設(shè)設(shè)計(jì)要求。檢驗(yàn)方法:觀察察、尺量檢查查。管溝底溝底層應(yīng)應(yīng)是原土層,或或是夯實(shí)的回回填土,溝底底應(yīng)平整,坡坡度應(yīng)順暢,不不得有尖硬的的物體、石塊塊等。檢驗(yàn)方法:觀察察檢查。如溝為巖石、不不易清除的塊塊石或?yàn)榇T石石層時(shí),溝底底應(yīng)下挖1000~200mmm,填鋪細(xì)紗紗或粒徑不大大于5mm的細(xì)土土,夯實(shí)到溝溝底標(biāo)高后,方方可進(jìn)行管道道敷設(shè)。檢驗(yàn)方法:觀察察和尺量檢查查管溝回填土,管管頂上部2000mm以內(nèi)內(nèi)應(yīng)用砂子或或無(wú)塊石及凍凍土塊的土,并并不得用機(jī)械械回填;管頂頂上部5000mm以內(nèi)不不得回填直徑徑大于1000mm的塊石石和凍土塊;;500mmm以上部分回回填土中的塊塊石和凍土塊塊不得集中。上上部用機(jī)械回回填時(shí),機(jī)械械不得在管溝溝上行駛。檢驗(yàn)方法:觀察察和尺量檢查查。4.5施工過(guò)過(guò)程控制規(guī)范范室外消防給水管管道設(shè)計(jì)壓力力為1.2Mpa,試驗(yàn)壓力力為1.6Mpa;室外工業(yè)業(yè)水管的工作作壓力與驗(yàn)收收壓力分別為為0.65MMpa,1.2Mpa;室外生活活水管的工作作壓力與驗(yàn)收收壓力分別為為0.60MMpa,1.2Mpa。管道安裝及驗(yàn)收收標(biāo)準(zhǔn),按::《給水鋼絲網(wǎng)骨骨架塑料復(fù)合合管道工程技技術(shù)規(guī)程》(CECS1181.20005)《給排水管道工工程施工及驗(yàn)驗(yàn)收規(guī)范》(GB502268-977)《中華人民共和和國(guó)國(guó)家標(biāo)準(zhǔn)準(zhǔn)建筑給水排排水及采暖工工程施工質(zhì)量量驗(yàn)收規(guī)范》GB502442-20002《埋地高密度聚聚乙烯中空壁壁纏繞結(jié)構(gòu)排排水管道工程程技術(shù)規(guī)程》(DBJ/T15-333-20033)《室外給水管道道附屬構(gòu)筑物物》(05S5002)《室外消火栓安安裝》(01S2001)《鋼質(zhì)管道聚乙乙烯粘帶防腐腐層技術(shù)標(biāo)準(zhǔn)準(zhǔn)》(SY/T00414-22007)5、質(zhì)量控制點(diǎn)點(diǎn)的設(shè)置和質(zhì)質(zhì)量通病預(yù)防防5.1質(zhì)量目標(biāo)標(biāo)根據(jù)工程總體質(zhì)質(zhì)量目標(biāo)和專(zhuān)專(zhuān)業(yè)分項(xiàng)目標(biāo)標(biāo),本項(xiàng)目的的質(zhì)量目標(biāo)為為:分項(xiàng)工程程驗(yàn)收合格率率達(dá)100%。5.2質(zhì)量控制制及質(zhì)量通病病預(yù)防序號(hào)質(zhì)量通病預(yù)想預(yù)防措施1埋地管道斷裂做好管基處理,按按設(shè)計(jì)要求填填土夯實(shí)2閥門(mén)井深度不夠夠,地上消火火栓的頂部出出水口距井蓋蓋底部距離小小于400mmm準(zhǔn)確控制埋地管管道坐標(biāo)及標(biāo)標(biāo)高3管道沖洗數(shù)遍,水水質(zhì)仍達(dá)不到到設(shè)計(jì)要求和和施工規(guī)范規(guī)規(guī)定管道連接前,管管膛清掃干凈凈5.3室外管網(wǎng)網(wǎng)安裝的控制制點(diǎn)的設(shè)置序號(hào)控制點(diǎn)檢驗(yàn)單位班組施工隊(duì)項(xiàng)目部監(jiān)理控制點(diǎn)1定位放線★★★★W2溝槽開(kāi)挖★★★W3溝底處理★★★H4管道防腐★★★★H5管道安裝★★★★H6給水管道通水、試試壓★★★★S7排水管道灌水試試驗(yàn)★★★★S8管溝回填★★★★H9管道沖洗與消毒毒★★★★HR:記錄確認(rèn)點(diǎn)點(diǎn)W:見(jiàn)證點(diǎn)H:停工待檢檢點(diǎn)S:連續(xù)監(jiān)視視監(jiān)護(hù)5.4質(zhì)量標(biāo)標(biāo)準(zhǔn)及要求序號(hào)項(xiàng)目名稱(chēng)執(zhí)行驗(yàn)收標(biāo)準(zhǔn)備注1電力建設(shè)施工質(zhì)質(zhì)量驗(yàn)收及評(píng)評(píng)定規(guī)程第1部分:土建建工程DL/T52210.1-220052火電施工質(zhì)量檢檢驗(yàn)及評(píng)定標(biāo)標(biāo)準(zhǔn)(焊接篇篇)建質(zhì)[19966]111號(hào)3火電施工質(zhì)量檢檢驗(yàn)及評(píng)定標(biāo)標(biāo)準(zhǔn)(第十篇篇加工配置)(83)水電基基火字第137號(hào)4火電工程調(diào)整試試運(yùn)質(zhì)量檢驗(yàn)驗(yàn)及評(píng)定標(biāo)準(zhǔn)準(zhǔn)建質(zhì)[19966]111號(hào)5檢測(cè)方法6火電施工質(zhì)量檢檢驗(yàn)及評(píng)定標(biāo)標(biāo)準(zhǔn)6、作業(yè)的安全全要求和作業(yè)業(yè)的安全危害害因素辯識(shí)和和控制6.1作業(yè)的的安全要求作業(yè)的安全要求求.1對(duì)參加施工工管理的操作作人員進(jìn)行施施工前技術(shù)、質(zhì)質(zhì)量、安全交交底,實(shí)行全全員簽字,施施工工期超過(guò)過(guò)1個(gè)月的重復(fù)復(fù)進(jìn)行技術(shù)、質(zhì)質(zhì)量、安全交交底,明確分分工和責(zé)任。.2現(xiàn)場(chǎng)施工區(qū)區(qū)均設(shè)立專(zhuān)職職安全員,進(jìn)進(jìn)行監(jiān)督檢查查,發(fā)現(xiàn)問(wèn)題題及時(shí)采取措措施。.3所有參加作作業(yè)人員必須須認(rèn)真遵守《電電力建設(shè)安全全工作規(guī)程》和和《電力建設(shè)設(shè)安全健康與與環(huán)境管理工工作規(guī)定》,杜杜絕“三違”現(xiàn)象(違章章指揮、違章章作業(yè)、違反反勞動(dòng)紀(jì)律)。.4進(jìn)入施工區(qū)區(qū)必須戴安全全帽,穿工作作服,不準(zhǔn)穿穿拖鞋、高跟跟鞋,非施工工人員不準(zhǔn)進(jìn)進(jìn)入施工現(xiàn)場(chǎng)場(chǎng)。.5嚴(yán)格按照施施工機(jī)械操作作規(guī)程施工,對(duì)對(duì)機(jī)械設(shè)備非非專(zhuān)業(yè)人員不不得動(dòng)用,機(jī)機(jī)械操作人員員必須持有效效的上崗證件件方可作業(yè)。.6各種工具(鍬鍬、鎬、鋤等等)必須堅(jiān)實(shí)實(shí),工具把柄柄應(yīng)用堅(jiān)硬的的木料制成,表表面必須刨光光。鍬、鎬、鋤鋤等應(yīng)有倒楔楔子使其安裝裝牢固,操作作人員在使用用這些工具時(shí)時(shí)一定要注意意前后方同時(shí)時(shí)作業(yè)的人員員的安全距離離,防止碰傷傷。.7所有電源設(shè)設(shè)備均應(yīng)設(shè)有有漏電保護(hù)器器,定期檢查查,防止觸電電。.8夜間施工應(yīng)應(yīng)有足夠的照照明,照明線線不得沿地面面敷設(shè),以防防機(jī)械壓斷,造造成事故。.9所有機(jī)械設(shè)設(shè)備必須做到到早晚都檢查查,確保機(jī)械械工作性能良良好,安全作作業(yè)。.14臨時(shí)用電電線路要絕緣緣良好,并且且施工用工機(jī)機(jī)具要安裝漏漏電保護(hù)器,使使用前要對(duì)漏漏電保護(hù)進(jìn)行行試驗(yàn)以保證證漏電保護(hù)器器的可靠性。.15下雨時(shí)時(shí)要做好防觸觸電工作,雨雨后及時(shí)清理理積水。.17電源閘箱箱下班后切斷斷電源并鎖上上,用電設(shè)備備要有防雨措措施,非電工工人員嚴(yán)禁私私接電源線。.18電焊機(jī)按按國(guó)華電廠要要求設(shè)置在電電焊機(jī)集裝箱箱內(nèi),并有可可靠的保護(hù)接接零、接地措措施。.19焊工要持持證上崗,作作業(yè)時(shí)要穿好好絕緣鞋,戴戴焊工手套,焊焊接時(shí)必須使使用專(zhuān)用電焊焊帽和防護(hù)罩罩。6.1.1.119凡屬一、二二、三級(jí)動(dòng)火火范圍的焊、割割作業(yè),未辦辦理火審批手手續(xù),不準(zhǔn)進(jìn)進(jìn)行焊、割。6.1.1.220焊工不不了解焊、割割現(xiàn)場(chǎng)周?chē)榍闆r,不得進(jìn)進(jìn)行焊、割。6.1.1.221焊工不不了解焊件內(nèi)內(nèi)部是否安全全時(shí),不得進(jìn)進(jìn)行焊、割。6.1.1.222各種裝裝過(guò)可燃?xì)怏w體,元?dú)馊家阂后w和有毒物物質(zhì)的容器,未未經(jīng)徹底清洗洗,排隊(duì)危險(xiǎn)險(xiǎn)性之前,不不準(zhǔn)進(jìn)行焊、割割。6.1.1.223用可燃材材料作保溫層層、冷卻層、隔隔熱設(shè)備的部部位,或火星星能盡濺到的的地方,在未未采取切實(shí)可可靠的安全措措施之前,不不準(zhǔn)焊、割。6.1.1.224有壓力力或密閉的管管道、容器,不不準(zhǔn)焊、割。6.1.1.225焊、割部部位附近有易易燃易爆物品品,在未作清清理或未采取取有效的安全全措施之前,不不準(zhǔn)焊、割。6.1.1.226附近有有與明火作業(yè)相抵觸觸的工種在作作業(yè)時(shí),不準(zhǔn)準(zhǔn)焊、割。6.1.1.227與外單單位相連的部部位,在沒(méi)有有弄清有無(wú)險(xiǎn)險(xiǎn)情,或明知知存在危險(xiǎn)而而未采取有效效的措施之前前,不準(zhǔn)焊、割割。吊裝工作區(qū)應(yīng)有有明顯標(biāo)志,并并設(shè)專(zhuān)人警戒戒,與吊裝無(wú)無(wú)關(guān)人員嚴(yán)禁禁人內(nèi)。起重重機(jī)工作時(shí),起起重臂桿旋轉(zhuǎn)轉(zhuǎn)半徑范圍內(nèi)內(nèi),嚴(yán)禁站人人或通過(guò)。嚴(yán)禁在被運(yùn)輸、吊吊裝的工件上上站人指揮和和放置材料、工工具。構(gòu)件必須綁扎牢牢固,起吊點(diǎn)點(diǎn)應(yīng)通過(guò)構(gòu)件件的重心位置置,吊升時(shí)應(yīng)應(yīng)平穩(wěn),避免免振動(dòng)或擺動(dòng)動(dòng)。起吊構(gòu)件件時(shí),速度不不應(yīng)太快,不不得在高空停停留過(guò)久,嚴(yán)嚴(yán)禁猛升猛降降,以防構(gòu)件件脫落。構(gòu)件就位后臨時(shí)時(shí)固定前,不不得松鉤、解解開(kāi)吊裝索具具。構(gòu)件固定定后,應(yīng)檢查查連接牢固和和穩(wěn)定情況,當(dāng)當(dāng)連接確定安安全可靠,才才可拆除臨時(shí)時(shí)固定工具和和進(jìn)行下步吊吊裝。消防管理.1凡有明火的的地方,必須須有用火準(zhǔn)用用證,設(shè)專(zhuān)人人負(fù)責(zé),常檢檢查,常督促促,特別是夜夜間,確保安安全,防止火火災(zāi)事故發(fā)生生。.2嚴(yán)格按照照《電力建設(shè)設(shè)安全工作規(guī)規(guī)程》(第1部分:火力力發(fā)電廠DJ50009.1-22002)中“防火防爆”的要求進(jìn)行行施工區(qū)域消消防器材的配配備及布置。6.2施工危危險(xiǎn)因素和環(huán)環(huán)境因素辨識(shí)識(shí)及對(duì)策表施工條件項(xiàng)目名稱(chēng):輸煤煤系統(tǒng)室外消消防、工業(yè)水水、生活水及及生活污水管管道安裝序號(hào)危險(xiǎn)點(diǎn)描述控制對(duì)策實(shí)施負(fù)責(zé)人確認(rèn)簽證人場(chǎng)地和環(huán)境1在施工現(xiàn)場(chǎng)照明明不足在每個(gè)作業(yè)點(diǎn)安安裝充足的照照明燈具并能能正常投入使使用。序號(hào)危險(xiǎn)點(diǎn)描述控制對(duì)策實(shí)施負(fù)責(zé)人確認(rèn)簽證人2電焊機(jī)露天擺放放露天擺放的電焊焊機(jī)放在干燥燥場(chǎng)所,有棚棚遮蔽或使用用電焊機(jī)專(zhuān)用用箱3臨時(shí)施工平臺(tái)搭搭設(shè)、使用不不合理專(zhuān)業(yè)人員搭設(shè),驗(yàn)驗(yàn)收合格并掛掛牌后,方可可施工,并不不得超載使用用。4施工中廢棄物不不集中回收施工中廢棄物及及時(shí)清理,不不得亂扔亂拋拋,并集中回回收到指導(dǎo)定定存放處。5梯子、欄桿、平平臺(tái)不完善在梯子、平臺(tái)、欄欄桿不完善處處加臨圍欄、蓋蓋板并掛警示示牌。6施工現(xiàn)場(chǎng)有孔洞洞、溝槽施工現(xiàn)場(chǎng)的孔洞洞、溝槽加蓋蓋蓋板、圍欄欄;下方鋪設(shè)設(shè)安全網(wǎng)。作業(yè)和人員1在吊裝物下接料料或逗留,墜墜物傷人禁止在吊裝物下下通過(guò)停留,接接料人員必須須按操作規(guī)程程施工。2大錘脫手傷人使用大錘時(shí)拴保保險(xiǎn)繩,且對(duì)對(duì)面嚴(yán)禁站人人。3作業(yè)人員施工態(tài)態(tài)度不端正施工人員嚴(yán)禁嬉嬉戲、打斗,嚴(yán)嚴(yán)禁酒后作業(yè)業(yè)。4私拉亂接電源嚴(yán)禁私拉亂接電電源,電源拆拆線、維護(hù)由由專(zhuān)業(yè)電工負(fù)負(fù)責(zé)。5鋼絲繩使用不當(dāng)當(dāng)鋼絲繩必須有88倍以下保險(xiǎn)險(xiǎn)系數(shù)并在與與吊物尖銳棱棱角接觸處墊墊關(guān)圓板。序號(hào)危險(xiǎn)點(diǎn)描述控制對(duì)策實(shí)施負(fù)責(zé)人確認(rèn)簽證人6吊掛物脫落鋼絲繩與管道接接觸處墊防滑滑物,吊掛生生根牢固并進(jìn)進(jìn)行二次保護(hù)護(hù)。7起重區(qū)域、起重重臂下吊裝通通道有人設(shè)警戒區(qū)域,設(shè)設(shè)專(zhuān)門(mén)監(jiān)護(hù)人人,拒絕任何何人通過(guò)。使用工機(jī)具1電焊機(jī)無(wú)可靠接接地電焊機(jī)外殼必須須進(jìn)行保護(hù)接接零和重復(fù)接接地。2電動(dòng)工具漏電使用前進(jìn)行檢查查,確認(rèn)電動(dòng)動(dòng)工具完好并并裝有漏電保保護(hù)器。4工機(jī)具不合格或或損壞使用前進(jìn)行檢查查、維修。5操作非本專(zhuān)業(yè)工工機(jī)具嚴(yán)禁操作非本專(zhuān)專(zhuān)業(yè)的工機(jī)具具。6施工觸電施工場(chǎng)所要干燥燥、電焊二次次線使用膠皮皮軟線。電源源線架空,或或埋入地下。7鎖具安全系數(shù)低低安全系數(shù)達(dá)到88倍以上。8手拉葫蘆使用不不當(dāng)使用前檢查,修修理合格;使使用中必須受受力均勻,不不超載使用;;手鏈必須備備牢,防止滑滑脫。6.2.2環(huán)境境條件項(xiàng)目名稱(chēng):輸煤煤系統(tǒng)室外消消防、工業(yè)水水、生活水及及生活污水管管道安裝序號(hào)危險(xiǎn)點(diǎn)描述控制對(duì)策實(shí)施負(fù)責(zé)人確認(rèn)簽證人1在施工現(xiàn)場(chǎng)照明明不足在每個(gè)作業(yè)點(diǎn)安安裝充足的照照明燈具并能能正常投入使使用。2施工中廢棄物不不集中回收施工中

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論