《水污染控制》課程設(shè)計報告系別:專業(yè)班級:學(xué)生姓名:指導(dǎo)教師:(課程設(shè)計時間:2011年4月25日——2011年4月29日)1目錄1.課程設(shè)計目的················································32.課程設(shè)計題目描繪和要求·····································33.課程設(shè)計報告內(nèi)容············································43.1污水辦理方案工藝比較········································43.2主要污水辦理修建物選型······································63.3污水辦理修建物的主要設(shè)計參數(shù)································6污水泵房··················································6格柵的設(shè)計計算·············································7沉砂池的設(shè)計計算···········································8一般輻流式積淀池(初沉池)設(shè)計計算·························10曝氣池的設(shè)計計算···········································11二沉池的設(shè)計計算···········································15消毒池····················································173.4污水辦理協(xié)助修建物設(shè)計······································173.5污水辦理廠平面部署設(shè)計······································183.6污水辦理廠高程部署設(shè)計······································193.7設(shè)計計算····················································194.總結(jié)·························································20參照文件························································212課程設(shè)計目的經(jīng)過污水辦理廠課程設(shè)計,穩(wěn)固學(xué)習(xí)成就,加深對《城市排水辦理》課程內(nèi)容的學(xué)習(xí)與理解,使學(xué)生學(xué)習(xí)使用規(guī)范、手冊與文件資料,進一步掌握設(shè)計原則、方法等步驟,達到穩(wěn)固、消化課程的主要內(nèi)容;鍛煉獨立工作能力,對污水辦理廠的主體修建物、協(xié)助設(shè)備、計量設(shè)備及污水廠整體規(guī)劃、管道系統(tǒng)做到一般的技術(shù)設(shè)計深度,培育和提高計算能力、設(shè)計和畫圖水平;在教師指導(dǎo)下,基本能獨立達成一其中、小型污水辦理廠工藝設(shè)計,鍛煉和提高學(xué)生剖析及解決工程問題的能力。2.課程設(shè)計題目描繪和要求2.1設(shè)計題目描繪設(shè)計題目某城市污水辦理廠工藝初步設(shè)計。設(shè)計內(nèi)容依據(jù)任務(wù)書所給定的資料,綜合運用所學(xué)的基礎(chǔ)、專業(yè)基礎(chǔ)和專業(yè)知識,設(shè)計一其中小型污水辦理廠。①確立污水辦理方法和工藝流程;②選擇各樣辦理修建物形式,并進行工藝設(shè)計計算(計算書中要附計算草圖);③估量各協(xié)助修建物的平面尺寸;④進行污水廠平面部署和高程部署。原始資料該城市位于湖北地域原始資料以下:①設(shè)計規(guī)模:近期:20萬人;遠期:40萬人;最大生活污水量為180-200l人天。.工業(yè)污水占最大生活污水量的1/3。按近期計算,預(yù)留遠期面積,用虛線畫出。②城市污水水質(zhì):SS=210mg/L,去除率為60%;0.82,0.9,1BOD=200mg/L,要求出水為25mg/L。3③當?shù)刈罡咚疁貫?0℃,。④夏天主導(dǎo)風向為東南風。⑤污水廠北面200米處有一條河流,最高洪水位為46.00米,常水位為42.00米。⑥污水廠地形平展,設(shè)計標高為48.00米;地下水位標高為42.00米,地基優(yōu)異。⑦城市污水總管從污水廠南面進入,干管終點水面標高為43.00米,管徑1200mm。2.2設(shè)計要求設(shè)計時間為一周。設(shè)計成就要求以下:設(shè)計說明書(含課程設(shè)計的目的、原始資料、工藝方案比較、污水辦理修建物選型及主要設(shè)計參數(shù)、污水廠的平面部署、高程部署及設(shè)計的心得領(lǐng)會等,A4紙打?。┰O(shè)計計算書(污水辦理修建物的設(shè)計計算、高程計算、草圖)污水辦理廠總平面圖一張(1號圖,1∶500或1:400);污水辦理廠高程圖一張(1號圖,坐標紙,橫向1∶500或1:400,縱向1∶100或1:50);圖紙要求:部署合理、圖面整齊、按畫圖規(guī)定制圖。3.課程設(shè)計報告內(nèi)容3.1污水辦理工藝方案比較城市污水辦理廠的主要任務(wù)就是對城市污水進行無害化辦理,使之達到國家規(guī)定的城市污水排放標準,而后排放或利用,達到環(huán)境保護的目的。在辦理工藝上力爭設(shè)備簡單,運行方便,辦理成本低,辦理成效明顯。當前國內(nèi)常用的城市污水辦理工藝有氧化溝、SBR(間歇式活性污泥法)、AB法(吸附-生物降解工藝)、A/O(缺氧-好氧工藝)法及A2/O法(厭氧-缺氧-好氧生物脫氮除磷工藝)等。(2)工藝比較①城市污水辦理廠的工藝選用往常要先考慮污水廠的規(guī)模。依據(jù)我國的詳細狀況,大概上分為大型、中型和小型污水辦理廠。規(guī)模大于10萬米3/天的為大型污水辦理廠,中型污水辦理廠的規(guī)模為10萬米3/天,規(guī)模小于1萬米3/天的4是小型污水辦理廠。大型城市污水辦理廠的精選工藝是傳統(tǒng)活性污泥法及其改良型A/O法、A2/O法。②在方案比選時,主要控制的條件實用地范圍、尾水排放、污泥出路、地質(zhì)條件、發(fā)展余地、管理水平、運行花費、工程投資、環(huán)境影響等諸方面。在知足出水水質(zhì)各項指標前提下,應(yīng)側(cè)重研究運行花費與管理水平。對擁有脫氮除磷功能的水辦理方法比較,中小規(guī)模污水辦理廠采納氧化溝、SBR法擁有顯然長處,而大型污水辦理廠A/O法及A2/O法還是首選方案。工藝種類氧化溝SBR法2/O法A技術(shù)比較1.污水在氧化溝1.辦理流程短,1.低成本,高效內(nèi)的逗留時間控制靈巧能,能有效去長,污水的混2.系統(tǒng)辦理修建除有機物合成效好物少,緊湊,2.能快速正確地2.污泥的BOD負節(jié)儉占地檢測污水辦理荷低,對水質(zhì)廠出入水質(zhì)的的改動有較強變化的適應(yīng)性經(jīng)濟比較可不獨自設(shè)二沉投資省,運行花費池,使氧化溝二沉低,比傳統(tǒng)活性污池合建,節(jié)儉了二泥法基建花費低沉池合污泥回流30%
能耗低,營運花費較低,規(guī)模越大優(yōu)勢越顯然系統(tǒng)合用范圍中小流量的生活中小型辦理廠居大中型污水辦理污水和工業(yè)廢水多廠穩(wěn)固性一般一般穩(wěn)固本設(shè)計城市污水辦理廠的污水辦理采納A2/O。A2/O工藝將生物反響池分為厭氧池、缺氧池和氣氧池。在厭氧階段,從沉淀池排出的含磷回流污泥同原污水一同進入,聚磷酸菌開釋磷,同時部分有機物開始進行氨化。隨后污水進入缺氧反響器,本反響器的首要功能是脫氮,硝態(tài)氮是經(jīng)過內(nèi)循環(huán)由好氧反響器送來的,循環(huán)的混淆液量較大,一般為2Q(Q為原污5水流量)。混淆液從缺氧反響器進入好氧反響器——曝氣池,這一反響器是多功能的,去除BOD,硝化和汲取磷等項反響都在本反響器內(nèi)進行。這三項反響都是重要的,混淆液中含有NO3N,污泥中含有剩余的磷,而污水中的BOD(或COD)則獲得去除。流量為2Q的混淆液從這里回流缺氧反響器。積淀池的功能是泥水分別,污泥的一部分回流厭氧反響器,上清液作為辦理水排放。污水辦理廠A2/O工藝流程以下圖。工藝特色:工藝流程比較簡單;厭氧、缺氧、好氧交替運行,不利于絲狀菌生殖,無污泥膨脹之虞;無需投藥,運行花費低。3.2主要污水辦理修建物選型格柵采納的是機械清渣式平面格柵中的中格柵,沉砂池采納的是平流式沉砂池,積淀池為輻流式,曝氣池采納的是采納傳統(tǒng)曝氣A2O工藝,二沉池也為輻流式積淀池。3.3污水辦理修建物的主要設(shè)計參數(shù)污水泵房選泵依照:①設(shè)計水量應(yīng)按最大時水量Qmax考慮,并知足最大充滿度時大流量要求②選泵時應(yīng)盡量選擇同種類泵,以便于檢修,但還需知足底流量是的需要。③泵站修建物不允許地下滲透,應(yīng)設(shè)有超出地下水位0.5m的防水設(shè)備。6④污水泵站的集水池與機器合建在同一修建物內(nèi)時,兩者之間需要用防水墻分開,不允許漏水。格柵的設(shè)計計算格柵是由一組平行的金屬柵條或篩網(wǎng)制成,被安裝在污溝渠道、泵房集水井的入口或污水辦理廠的端部,用以截阻大塊呈懸浮壯或飄蕩壯的污物,如纖維、碎皮、毛發(fā)、木屑、塑料制品等,以便減少后繼辦理修建物的辦理負荷,并使之正常運行。人工清渣占地許多,且勞動強度大,而機械清渣不但占地少、維修方便,同時降低了勞動強度,并能推行自控。按形狀,可分為平面格柵和曲面格柵兩種;按柵條凈空隙,可分為粗格柵50~100mm)、中格柵(10~40mm)、細格柵(3~10mm)三種;按清渣方式,可分為人工消除格柵和機械消除格柵兩種。設(shè)計數(shù)據(jù)以下:20104180133560LsQmax(1)48000md0.56ms10003K=1.35設(shè)柵前水深h=0.5m,過柵流速取0.9m/s,中格柵,柵條空隙20mm,安裝角為60°。柵條空隙數(shù):Qmaxsin60o0.56sin60o58,nehv0.020.50.9柵橫寬度(取柵條寬S=0.01m):S(n1)en0.01(581),B取1800m。進溝渠道漸寬部分長度(取進溝渠寬1.3m,漸寬部分睜開角1=20°):此時進溝渠道內(nèi)的流速為0.86ms.l1BB10.69m柵槽與出溝渠連結(jié)處的漸寬部分長度:2tg2tg2001l2l10.690.35m過柵水頭損失:因柵條為矩形,取k=3.227h1v2sinks2ge
4v240.923k2.420.013030.103msin0.022sin602g9.81柵后總高度(取柵前渠道超高h2=0.3m):柵前槽高:H1hh20.80m.Hhh1h20.50.1030.3=0.90m柵橫總長度:Ll1l2H0.690.350.83.0mtg60otg60o每天柵渣量:0.07m310m3WQmaxW186400864002.51m3dK總10001.351000則采納機械清渣計算草圖以下:8沉砂池的設(shè)計計算沉砂池的功能是去除比重比較大的無機物顆粒,設(shè)于首次積淀池前,以減少積淀池負荷及改良污泥辦理修建物的辦理條件。常用的沉砂池有平流沉砂池、曝氣沉砂池、多爾沉砂池和鐘式沉砂池等。該污水廠就是采納的平流式沉砂池。其設(shè)計數(shù)據(jù)以下:1)沉砂池水流部分長度(沉砂池兩閘板之間的長度)(取最大流速0.2m,水力逗留時間50s):Lvt0.25010m2)水流斷面面積:AQmax0.562v2.8m0.23)池總寬度(取有效水深1.0m):BA2.82.8m1h2864004.81042386400Qmaxtx110534)沉沙斗容積:v105K總1051.351.8m5)用四個沉砂斗,每個沉沙斗得體積:V1V1.80.45m344a=0.5m,去斗壁傾角60°、斗高’采納斗狀,其斗底邊長h3=0.65m20.650.51.25m則上面長:btg60o沉沙斗體積:V‘1h3'1.2520.520.53m30.45m3切合要求35)沉砂池總高度:hh1h2h32.18m6)驗算:QminOmin0.560.41m3sKz1.35vminQmin0.41(合格)nw11.4計算草圖以下:9一般輻流式積淀池(初沉池)設(shè)計計算積淀池按池內(nèi)水流方向的不一樣,可分為平流式積淀池,輻流式積淀池和豎流式沉淀池。本污水廠采納的是輻流式初沉池,其多為機械排泥,運行靠譜,管理較簡單;排泥設(shè)備已定型化但較復(fù)雜,對施工要求高。合用于大、中型污水辦理廠。其設(shè)計數(shù)據(jù)以下:1)積淀池表面積取q02.4m3m2h,n=2座A1Qmax2000416.7m2nq022.4D4A14416.723m,取D=23m2)池內(nèi)有效水深取積淀時間t=1h.h2q0t2.412.4m3)積淀池總高度每池每天污泥量計算W1SNt0.52010448.3m3100n1000224式中S取0.5l(p.d),因為機械刮泥,所以在斗內(nèi)儲存時間用4h。10污泥斗高度:h5r1-r2tg2-1tgom601.73污泥斗容積:V1h5221.73121212.7m33r1r1r2r2322底坡落差:h4R-r0.0514-20.050.6mV2h42Rr20.6214222143.3m2(Rr1)1433污泥總?cè)莘e:V1V212.7143.3156m38.3m3積淀池總高度(設(shè)h10.3m,h30.5m):H0.32.40.50.61.73m5.53m4)積淀池周邊的高度:h1h2h35)徑深比較核:D239.6合格(在9到12之間)h22.4計算草圖以下:曝氣池的設(shè)計計算本污水廠采納的是傳統(tǒng)活性污泥法中的A2OA2O生物脫氮工藝將傳工藝,統(tǒng)的活性污泥、生物硝化工藝聯(lián)合起來,揚長避短,更有效的去除水中的有機物。此法即是往常所說的厭氧-缺氧-好氧法,污水挨次經(jīng)過厭氧池-缺氧池-好氧池被降解。采納的曝氣方式是鼓風曝氣系統(tǒng)。在本設(shè)計中應(yīng)試慮曝氣池運行方式11的靈巧性喝多樣化。即:以傳統(tǒng)活性污泥法系統(tǒng)作為基礎(chǔ),又可按階段曝氣系統(tǒng)和重生-曝氣系統(tǒng)運行。其設(shè)計數(shù)據(jù)以下:a、曝氣池計算與各部分為尺寸確實定:BOD—污泥負荷確實定:Sa=200(1-25%)=150BOD5=7.1bXaCe0.09=6.4辦理水中BOD值:25-6.4=18.6mgL150-18.687.6%150NsK2Sef/K2值取0.0185;Se=18.6;fMLVSS/MLSS0.75;代入各值后得:Ns0.01855/(kgMLSSd)計算結(jié)果確證,Ns值取0.3適合。⑵確立混淆液污泥濃度(X):XRr106/[(1R)SVI]0.51.21063636mg/l3600mg/l(10.5)110⑶確立曝氣池容積:VQSa/(NsX)480001506667m30.33600⑷確立曝氣池各部位尺寸:設(shè)4組曝氣池,每組容積為:66673333m33池深:取4.5m,則每組曝氣池的面積為;F3333/4.5740.7m2池寬:取5m。B1.11m介于1-2之間,切合規(guī)定H池長:F/B740.7/5148.1mL/B148.1/529.610,切合規(guī)定。設(shè)五廊道式曝氣池,廊道長:L1L/5148.1/529.6m取30m取超高0.5m,則池總高度為:4.5+0.5=5.0mb、曝氣系統(tǒng)的計算與設(shè)計(本設(shè)計采納鼓風曝氣系統(tǒng)):12‘0.16(1)均勻是需氧量計算O2a'QSrb'VXv=0.5148000a0.51;b150-25+0.1666672500=3060+2666.8=5726.8kgd=238.6kgh最大時需氧量的10001000計算:依據(jù)原始數(shù)據(jù)K=1.35O2(max)150250.16666725004131kg/d283.2kg/h10001000⑵每天去除的BOD5值:4800015025BODr10006000kg/d⑶拿出每千克BOD的需氧量:O25726.8/kgBOD0.95kgO26000⑷最大時需氧量與均勻時需氧量之比:O2(max)/O2283.21.2238.6C.供肚量的計算采納網(wǎng)狀膜型中微孔空氣擴散器,敷設(shè)于距池底0.2m處,吞沒水深4.3m,計算溫度定為30℃。水中溶解氧飽和度:Cs(20)=9.17mg/L;Cs(30)=7.63mg/L空氣擴散器出口處的絕對壓力(Pb)計算以下:53535Pb=1.013×10+9.8×10H=1.013×10+9.8×10×4.3=1.4310×Pa(2)空氣走開曝氣池面時,氧的百分比按下式計算:Ot=21(1-EA)/[79+21(1-EA)]×100%EA——空氣擴散器的氧轉(zhuǎn)移效率,對網(wǎng)狀膜型中微孔空氣擴散器,取值10%。代入EA值,得:Ot=21(1-0.1)/[79+21(1-0.1)]100%=19×.3%曝氣池混淆液中均勻氧飽和度(按最不利的溫度條件考慮)按下式計算,即:5Csb(T)=Cs(Pb/2.02610×+Ob/42)13最不利溫度條件按30℃考慮,代入各值,得:Csb(30)=7.63×(1.43/2.026+19.3/42)=8.89mg/L換算為在20℃條件下,脫氧清水的充氧量,按下式計算,即:R0=RCs(20)/[(T20··Csb(T)-C)·1.024]取值=0.82;=0.9;C=2.0;=1.0代入各值,得:R0(3020)=238.6×9.17/[0.82(0×.9×1.0×8.89-2.0)1.×024]=351kg/h相應(yīng)的最大時需氧量為:R0(3020)=283.2×9.17/[0.82(0×.9×1.0×8.89-2.0)1.×024]=601kg/h曝氣池均勻時供肚量按下式計算,即:Gs=R0/(0.3EA)×100代入各值,得:3Gs=351/(0.310)××100=11700m/h曝氣池最大時供肚量3Gs=601/(0.312)××100=13867m/h去除每kgBOD5的供肚量:11700/600024=46×.8m3空氣/kgBOD3每m污水的供肚量:3311700/4800024=5×.85m空氣/m污水本系統(tǒng)的空氣總用量;提高會留污泥所需空肚量為0.6480009600m3h24總需肚量:13867+9600=23467m3hd、空器管系統(tǒng)計算在相鄰的兩個廊道的隔墻上設(shè)一根干管,共5根干管。在每個干根上設(shè)10對配14氣豎管,共20條配氣豎管。全曝氣池共設(shè)100條配氣豎管。每根豎管的氧肚量為:13867277m3/h50曝氣池平面面積為:30501500m2每個空氣擴散器的服務(wù)面積按0.57計,則所需個數(shù)15000.4
3062個本設(shè)計采納5200個空氣擴散器,每個豎管上安設(shè)的空氣擴散器的數(shù)量為:310062個10050每個空氣擴散器的配肚量為138674.47m3/h3100二沉池的設(shè)計計算:1.已知條件本設(shè)計采納一般輻流式積淀池。最大設(shè)計流量為2000m3/h,曝氣池中懸浮固體濃15度X=3600mg/L,二沉池底微生物固體濃度Xr=106/SVI·r=106/110×1.2=7576mg/L,污泥回流比R=50%。2.設(shè)計計算積淀池部分水面面積F依據(jù)活性污泥法辦理特征,選用表面負荷q=1.2m3/(m2·h),設(shè)4座積淀池n=4,則單池面積為:2F=Qmax/(n·q)=2000/(41×.2)=416.7m(2)池子直徑D=(4F/π)0.5=(4×416.7/π)0.5=23m校核固體負荷GG=24(1+R)·Q0·X/F=24×(1+0.5)×2000×3.6/(416.74)=155×.5kg/(m2·d),切合要求。積淀部分有效水深h2,設(shè)積淀時間t=2h,則h2=qt=1.22=2×.4m污泥區(qū)的容積V設(shè)計采納周邊傳動的刮吸泥機排泥,污泥區(qū)容積按2h貯泥時間確立:V=2T(1+R)·Q·X/[24(X+Xr)]=2×2×1.5×35556×3600/[24(3600+7576)=2863×.31m3每個積淀池污泥區(qū)的容積為'3V=2863.31/4=715.83m污泥區(qū)高度h4污泥斗高度設(shè)池底的徑向坡度為0.05,污泥斗底部直徑D2=1.5m,上部直徑D1=3.0m,傾角60°,則h4'=(D1-D2)tan60°/2=(3.0-1.5)tan60°/2=1.3m'223V1=πh4(D1+D1D2+D2)/12=1.3π(9+3×1.5+1.51×.5)/12=5.36m圓錐體高度h4''=(D-D1)×0.05/2=(26.6-3.0)0.05/2=0×.59m''223V2=πh4(D+DD1+D1)/12=0.59π(26.626×.6+26.63×.0+9)/12=123m豎直段污泥部分的高度h4'''=(V-V1-V2)/F=(715.83-5.36-123)/416.7=1.41m16污泥區(qū)總高度h4=h4'+h4''+h4'''=1.3+0.59+1.41=3.3m積淀池的總高度H設(shè)超高h1=0.3m,緩沖層高度h3=0.5m,則H=h1+h2+h3+h4=0.3+2.4+0.5+3.3=6.5m計算草圖以下消毒池1)消毒設(shè)備:接觸池消毒——矩形折板式,加氯消毒。2)設(shè)計依照:⑴接觸時間T30min,并保證余氯許多于0.5mgL;⑵加氯量為5~10mgL污水;3.4污水辦理協(xié)助修建物設(shè)計計量槽1)概括:為提高水廠的工作效率和運行管理水平,并累積技術(shù)資料,總結(jié)運轉(zhuǎn)經(jīng)驗,為此后辦理廠的設(shè)計供給靠譜的數(shù)據(jù),一定設(shè)置計量設(shè)備,正確掌握污水量,污泥量,空肚量,以及動力耗費等。氣體流量和耗電量有現(xiàn)成的計量裝置可資應(yīng)用,本設(shè)計只波及污水的計量設(shè)備。設(shè)計依照:⑴計量槽應(yīng)設(shè)在渠道的直線上,渠道的長度不該小于渠道寬度的8~10倍,在計量槽上游,直線段不小于渠寬的2~3倍,下游不小于4~5倍。當下游有跌水而無回水影響時,可適合縮短。17⑵計量槽中心線應(yīng)與渠道中心線重合,上下游渠道的坡度應(yīng)保持均勻,但坡度可以不一樣。⑶計量槽喉寬一般采納上游渠寬的1/3-1/2。⑷當喉寬w為0.25米時,H2/H10.64為自由流,大于此數(shù)為潛沒流。當喉寬米時,H2/H10.70為自由流,大于此數(shù)為潛沒流。⑸計量槽為自由流時,只要計上游水位,而當為潛沒流時,則需同時計上下游水位。所以,本設(shè)計采納自由流狀況,但不論自由流或潛沒流都應(yīng)在上下游設(shè)觀察孔。⑹計算計量槽時,除計算其經(jīng)過最大流量時的工作條件外,尚需計算經(jīng)過最小流量時的條件。濃縮池(1)型式:一般采納離心式濃縮池、浮選式濃縮池和重力濃縮池。重力濃縮池分為:間歇式和連續(xù)式.本設(shè)計采納重力間歇式濃縮池,運行時,應(yīng)清除濃縮池中的上清夜,騰出池容,再投入待濃縮的污泥,為此在濃縮池深度方向上的不一樣高度設(shè)上清夜排出管。(2)設(shè)計參數(shù):⑴濃縮時間采納20h。s當首次積淀污泥時,其含水率一般為95%~97%,污泥固體負荷采納80—120kg/m2d。濃縮后污泥含水率可達97%左右。⑶污泥池的有效水深一般采納4米。⑷濃縮池的上清液。應(yīng)從頭回流到初沉池行進行辦理。3.5污水辦理廠平面部署設(shè)計污水廠平面部署及總面積污水辦理廠平面部署包含:辦理修建物的部署,辦公,化驗及其余建筑物的部署,以及各樣管道、道路、綠化等部署。(1)平面部署的一般原則辦理權(quán)筑物的部署應(yīng)緊湊,節(jié)儉用地便于管理。辦理修建物應(yīng)盡可能地按流程次序部署,以防止管線迂回,同時應(yīng)充分利用地18形,減少土方量。3.常常有人工作的建筑物如辦公化驗等用房應(yīng)部署在夏天主風向的上風一方,在北方地域應(yīng)試慮朝陽。在部署總圖時,應(yīng)試慮安裝充分的綠化地帶??倛D部署應(yīng)試慮遠近期聯(lián)合有條件時,可按遠景規(guī)劃水量部署并將修建物分紅若關(guān)連列,分期建設(shè)。修建物之間的距離應(yīng)試慮敷設(shè)管渠的地點,運行管理的需要和施工的要求,一般系用5~10。污泥辦理修建物應(yīng)盡可能部署成獨自的組合,以策安全,并
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025版毛竹種植技術(shù)培訓(xùn)與推廣合同4篇
- 二零二五年度高端酒店地板裝修與維護合同3篇
- 2025年綠色生態(tài)園區(qū)物業(yè)管理委托服務(wù)合同書3篇
- 2025年度高端珠寶私人居間買賣合同3篇
- 2025年物業(yè)服務(wù)企業(yè)環(huán)保責任合同附件模板3篇
- 2025版臨時自駕游租車合同細則4篇
- 2025年度大型設(shè)備臨時運輸合同4篇
- 2025年版大渡口市吸污車輛租賃與廢棄物運輸合同3篇
- 2025年度鋁材倉儲物流服務(wù)合同4篇
- 專業(yè)管理體系認證指導(dǎo)服務(wù)協(xié)議版A版
- 上海紐約大學(xué)自主招生面試試題綜合素質(zhì)答案技巧
- 辦公家具項目實施方案、供貨方案
- 2022年物流服務(wù)師職業(yè)技能競賽理論題庫(含答案)
- ?;钒踩僮饕?guī)程
- 連鎖遺傳和遺傳作圖
- DB63∕T 1885-2020 青海省城鎮(zhèn)老舊小區(qū)綜合改造技術(shù)規(guī)程
- 高邊坡施工危險源辨識及分析
- 中海地產(chǎn)設(shè)計管理程序
- 簡譜視唱15942
- 《城鎮(zhèn)燃氣設(shè)施運行、維護和搶修安全技術(shù)規(guī)程》(CJJ51-2006)
- 項目付款審核流程(visio流程圖)
評論
0/150
提交評論