版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
DownloadedbyHarlanJack(txsjd666@163.com)onOct20,2023,12:42amPDT
JOINTINDUSTRYSTANDARD
IPC/JEDECJ-STD-033D
April2018
SupersedesIPC/JEDECJ-STD-033C-1August2014
Handling,Packing,ShippingandUseofMoisture,
Reflow,andProcessSensitiveDevices
Notice
JEDECandIPCStandardsandPublicationsaredesignedtoservethepublicinterestthrougheliminatingmisunderstandingsbetweenmanufacturersandpurchasers,facilitatinginterchangeabilityandimprovementofproducts,andassistingthepurchaserinselectingandobtainingwithminimumdelaytheproperproductforhisparticularneed.ExistenceofsuchStandardsandPublicationsshallnotinanyrespectprecludeanymemberornonmemberofJEDECorIPCfrommanufacturingorsellingproductsnotconforming
tosuchStandardsandPublications,norshalltheexistenceofsuchStandardsandPublicationsprecludetheirvoluntaryusebythoseotherthanJEDECandIPCmembers,whetherthestandardistobeusedeitherdomestically
orinternationally.
RecommendedStandardsandPublicationsareadoptedbyJEDECand
IPCwithoutregardtowhethertheiradoptionmayinvolvepatentsonarticles,materials,orprocesses.Bysuchaction,JEDECandIPCdonotassumeanyliabilitytoanypatentowner,nordotheyassumeanyobligationwhatever
topartiesadoptingtheRecommendedStandardorPublication.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsofliabilitiesforpatentinfringement.
ThematerialinthisjointstandardwasdevelopedbytheJEDECJC-14.1CommitteeonReliabilityTestMethodsforPackagedDevicesandtheIPCPlasticChipCarrierCrackingTaskGroup(B-10a)
ForTechnicalInformationContact:
JEDEC
SolidStateTechnologyAssociation3103North10thStreet,Suite240-SArlington,VA22201-2107
Tel703907.0026
Fax703907.7501
IPC
3000LakesideDrive,Suite105NBannockburn,Illinois
60015-1249
Tel847615.7100
Fax847615.7105
PleaseusetheStandardImprovementFormshownattheendofthisdocument.
?Copyright2018.JEDECSolidStateTechnologyAssociation,Arlington,Virginia,andIPC,Bannockburn,Illinois,USA.AllrightsreservedunderbothinternationalandPan-Americancopyrightconventions.Anycopying,scanningorotherreproductionofthesematerialswithoutthepriorwrittenconsentofthecopyrightholderisstrictlyprohibitedandconstitutesinfringementundertheCopyrightLawoftheUnitedStates.
IPC/JEDECJ-STD-033D
Handling,Packing,ShippingandUseofMoisture,Reflow,andProcessSensitiveDevices
AjointstandarddevelopedbytheJEDECJC-14.1CommitteeonReliabilityTestMethodsforPackagedDevicesandtheB-10aPlasticChipCarrierCrackingTaskGroupofIPC
Supersedes:
IPC/JEDECJ-STD-033C-1-
August2014
IPC/JEDECJ-STD-033C-
February2012IPC/JEDECJ-STD-033B.1
includesAmendment1-January2007
IPC/JEDECJ-STD-033B-
October2005
Usersofthispublicationareencouragedtoparticipateinthedevelopmentoffuturerevisions.
Contact:
IPC/JEDECJ-STD-033A-
July2002
IPC/JEDECJ-STD-033-
April1999JEDECJEP124
IPC-SM-786A-January1995
IPC-SM-786-December1990
JEDEC
SolidStateTechnologyAssociation3103North10thStreet,Suite240-SArlington,VA22201-2107
Tel703907.0026
Fax703907.7501
IPC
3000LakesideDrive,Suite105NBannockburn,Illinois
60015-1249
Tel847615.7100
Fax847615.7105
ThisPageIntentionallyLeftBlank
April2018 IPC/JEDECJ-STD-033D
Acknowledgment
Anydocumentinvolvingacomplextechnologydrawsmaterialfromavastnumberofsourcesacrossmanycontinents.WhiletheprincipalmembersofthePlasticChipCarrierCrackingTaskGroup(B-10a)ofthePackagedElectronicComponentsCommittee(B-10)areshownbelow,itisnotpossibletoincludeallofthosewhoassistedintheevolutionofthisstandard.Toeachofthem,themembersoftheIPCextendtheirgratitude.
PlasticChipCarrierCrackingTaskGroup
Chairman
StevenR.MartellNordsonSonoscan
JEDECJC14.1Committee
ChairmanIfeHsu
IntelCorporation
JointMoistureClassificationWorkingGroupMembers
JosephKane,BAESystemsPlatformSolutions
MudasirAhmad,CiscoRobertDiMaggio,ClariantMarkReese,ClariantFrancisClasse,Cypress
ChrisBrigham,EvansAnalyticalGroupMarkBurns,GlobalFoundries
ShiDanBing,HuaweiGuoFujan,HuaweiJiaoHuifang,Huawei
RussLewis,Hewlett-PackardCurtisGrosskopf,IBMCorporationAndreasPreussger,Infineon
DennisCerney,InfineonIfeHsu,IntelCorporationAlanLucero,IntelGautamVerma,Intel
KenMcGhee,JEDECPerryKeller,KeysightAshKumar,MicrochipDongieXie,Nvidia
BobKnoell,NXPSemiconductorsNicholasLycoudes,NXP
Semiconductors
StevanHunter,OnSemiMumtazBora,Peregrine
Semiconductor
RichardIodice,RaytheonCompanyJinhwanKim,Samsung
HeonSangLim,SamsungMianQuddus,Samsung
MichelleOgihara,SeikaMachineryInc.StevenMartell,SonoscanInc.
JamesBerry,TexasInstrumentsLarryTing,TexasInstruments
StephenTisdale,TisdaleEnvironmentalConsulting
BruceHughes,USArmy
Additionally,wewouldliketoexpressourappreciationtotheJEITAmembersfortheirsupportinimprovingJ-STD-033revD.
InMemorium
TheJointCommitteewouldliketoespeciallyacknowledgeJackT.McCullenandRichardL.ShookfortheiroutstandingcontributionsandleadershipinthedevelopmentofJ-STD-033.
iii
ThisPageIntentionallyLeftBlank
April2018 IPC/JEDECJ-STD-033D
TableofContents
FOREWORD 1
Purpose 1
Scope 1
AssemblyProcesses 1
MassReflow 1
LocalizedHeating 1
SocketedDevices 1
Point-to-PointSoldering 1
AqueousCleaning 1
Reliability 2
TermsandDefinitions 2
ActiveDesiccant 2
BarCodeLabel 2
BulkReflow 2
Carrier 2
Desiccant 2
FloorLife 2
HumidityIndicatorCard(HIC) 2
Manufacturer’sExposureTime(MET) 2
Moisture-BarrierBag(MBB) 2
Moisture-SensitiveIdentification(MSID) 2
Moisture-SensitivityLevel(MSL) 2
Rework 2
Process-SensitivityLevel(PSL) 2
ShelfLife(ofadeviceinasealedMBB) 2
SMD 3
SolderReflow 3
WaterVaporTransmissionRate(WVTR) 3
APPLICABLEDOCUMENTS(Normative) 3
AmericanSocietyforTestingandMaterials(ASTM) 3
ElectronicIndustriesAlliance(ECIA,JEDEC) 3
IPCStandards 3
JointIndustryStandards 3
DepartmentofDefense 3
DRYPACKING 3
Requirements 3
DryingofSMDPackagesandCarrierMaterialsBeforeBeingSealedinMBBs 4
DryingRequirements-Levels2a-5a 4
DryingRequirementsforCarrierMaterials 4
DryingRequirements 4
ExcessTimeBetweenBakeandBag 4
DryPack 4
Description 4
Materials 4
Labels 6
MoistureBarrierBagSealing 7
Dry-PackPrecautions 7
ShelfLife 8
DRYING 8
PostExposuretoFactoryAmbient 10
AnyDurationExposure 10
ShortDurationExposure 10
GeneralConsiderationsforBaking 11
HighTemperatureCarriers 11
LowTemperatureCarriers 11
PaperandPlasticContainerItems 11
BakeoutTimes 11
ESDProtection 11
ReuseofCarriers 11
SolderabilityLimitations 11
USE 11
IncomingBagInspection 11
UponReceipt 11
DeviceInspection 12
FloorLife 12
SafeStorage 12
DryPack 12
ShelfLife 12
DryAtmosphereCabinet 12
Reflow 12
OpenedMBB 12
ReflowTemperatureExtremes 12
AdditionalThermalProfileParameters 13
MultipleReflow 13
MaximumReflowPasses 13
DryingIndicators 13
ExcessHumidityinDryPack 13
FloorLifeorAmbientTemperature/HumidityExceeded.135.5.3 Level6SMDPackages 13
BOARDREWORK 13
DeviceRemoval,ReworkandRemount 13
RemovalforFailureAnalysis 14
RemovalandRemount 14
BakingofPopulatedBoards 14
v
IPC/JEDECJ-STD-033D April2018
DERATINGDUETOFACTORY
ENVIRONMENTALCONDITIONS 14
APPENDIXA TestMethodforReversible(Type1)
RHSpotsonaHumidityIndictorCard(HIC)usedwithElectronicDevicePackaging 16
APPENDIXB DerivationofBakeTables 17
APPENDIXC DesiccantUnitAbsorptionCapacity
TestMethodforVerification 18
APPENDIXD ChangesinJ-STD-033D 19
Figures
Figure3-1 TypicalDry-PackConfigurationforMoisture-
SensitiveSMDPackagesinShippingTubes 4
Figure3-2AHumidityIndicatorCard(HIC)–Type1 5
Figure3-2BHumidityIndicatorCard(HIC)–Type2 5
Figure3-3 Moisture-SensitiveIdentificationLabel
(Examples) 6
Figure3-4ACautionLabel(ExampleswithMSLonly) 7
Figure3-4BCautionLabel(ExampleswithMSLandPSL) 7
Figure3-5 MBBwithNoEvacuation(Example) 8
Figure3-6 MBBwithRecommendedLightAirEvacuation(Example) 8
Figure3-7 MBBwithTooMuch(Full)Evacuation
(Example) 8
FigureA-1 PhotoofTestingApparatus 16
Tables
Table3-1 Dry-PackingRequirements 4
Table3-2 TypicalReversible(Type1)HICSpot
Compliance 6
Table4-1 ReferenceConditionsforDryingMountedorUnmountedSMDPackages 9
Table4-2 SupplierBake:DefaultBakingTimesUsed
PriortoDryPack 10
Table4-3 ResettingorPausingtheFloor-LifeClock
atUserSite 10
Table5-1 MoistureClassificationLevel(MSL)and
FloorLifeperJ-STD-020 12
Table7-1 RecommendedEquivalentTotalFloor
Life(days)@20°C,25°C&30°C,35°CForICswithNovolac,Biphenyland
MultifunctionalEpoxies(Reflowatsametemperatureatwhichthedevicewasclassified)
MaximumPercentRelativeHumidity 15
vi
April2018 IPC/JEDECJ-STD-033D
Handling,Packing,ShippingandUseofMoisture,Reflow,
andProcessSensitiveDevices
FOREWORD
Theadventofsurfacemountdevices(SMDs)introducedanewclassofqualityandreliabilityconcernsregardingdamagesuchas‘‘cracksanddelamination’’fromthesolderreflowprocess.Thisdocumentdescribesthestandardizedlevelsoffloor-lifeexposureformoisture/reflowsensitiveSMDsalongwiththehandling,packingandshippingrequirementsnecessarytoavoidmoisture/reflowrelatedfailures.CompaniondocumentsJ-STD-020,J-STD-075andJEP113definetheclassificationprocedureandthelabelingrequirements,respectively.
Formoisturesensitivity,moisturefromatmospherichumidityenterspermeablepackagingmaterialsbydiffusion.AssemblyprocessesusedtosolderSMDstoprintedcircuitboards(PCBs)exposetheentirepackagebodytotemperatureshigherthan200°C.Duringsolderreflow,thecombinationofrapidmoistureexpansion,materialsmismatch,andmaterialinterfacedegradationcanresultincrackingand/ordelaminationofcriticalinterfaceswithinthedevice.
Typicalsolderreflowprocessesofconcernforalldevicesareconvection,convection/IR,infrared(IR),vaporphase(VPR),hotair
reworktools,andwavesolder,includingfullimmersion.
Non-semiconductordevicesmayexhibitadditionalprocesssensitivitiesbeyondmoisturesensitivitysuchasthermalsensitivity,
fluxsensitivityorcleaningprocesssensitivity.
PurposeThepurposeofthisdocumentistoprovidemanufacturersanduserswithstandardizedmethodsforhandling,packing,shipping,anduseofmoisture/reflowandprocesssensitivedevicesthathavebeenclassifiedtothelevelsdefinedinJ-STD-020orJ-STD-075.Thesemethodsareprovidedtoavoiddamagefrommoistureabsorptionandexposuretosolderreflowtemperaturesthatcanresultinyieldandreliabilitydegradation.Byusingtheseprocedures,safeanddamage-freereflowcanbeachieved.Thedry-packingprocessdefinedhereinprovidesaminimumshelflifeof12monthsfromthesealdate.
ScopeThisstandardappliestoalldevicessubjectedtobulksolderreflowprocessesduringPCBassembly,includingplasticencapsulatedpackages,processsensitivedevicesandothermoisturesensitivedevicesmadewithmoisture-permeablematerials(epoxies,silicones,etc.)thatareexposedtotheambientair.
AssemblyProcesses
MassReflowThisstandardappliestobulksolderreflowassemblybyconvection,convection/IR,infrared(IR),andvaporphase(VPR)processes.Itdoesnotapplytobulksolderreflowprocessesthatimmersethedevicebodiesinmoltensolder(e.g.,wavesolderingbottommounteddevices).SuchprocessesarenotallowedformanySMDsandarenotcoveredbythedevicequalificationsstandardsusedasabasisforthisdocument.
LocalizedHeatingThisstandardalsoappliestomoisture/reflowsensitiveSMDpackagesthatareremovedorattached
singlybylocalambientheating,i.e.,‘‘hotairrework.’’SeeClause6.
SocketedDevices
ThisstandarddoesnotapplytoSMDpackagesthataresocketedandnotexposedtosolderreflowtemperaturesduringeitherbulkrefloworreworkofadjacentdevices.SuchSMDpackagesarenotatriskanddonotrequiremoistureprecautionaryhandling.
Point-to-PointSolderingThisstandarddoesnotapplytoSMDpackagesinwhichonlytheleadsareheatedtoreflowthesolder,e.g.,hand-soldering,hotbarattachofgullwingleads,andthroughholebywavesoldering.Theheatabsorbedbythepackagebodyfromsuchoperationsistypicallymuchlowerthanforbulksurfacemountrefloworhotairreworkandmoistureprecautionarymeasuresaretypicallynotneeded.
AqueousCleaningFornon-cavitySMDstypicalshorttermaqueouscleaningprocesseswillnotimpactthefloorlife
(internalmoisturecontent).Specialconsiderationshouldbegiventonon-hermeticcavitypackages.
1
IPC/JEDECJ-STD-033D April2018
ReliabilityThemethodssetforthinthisspecificationensurethatanadequateSMDpackagereliabilitycanbeachievedduringandafterthePCBassemblyoperation,whentheSMDpackagesareevaluatedandverifiedbyJ-STD-020,J-STD-075,and/orbyJESD22-A113plusenvironmentalreliabilitytesting.
Note:Thisspecificationdoesnotaddressorensuresolderjointreliabilityofexternalinterconnectsforattacheddevices.
TermsandDefinitions
ActiveDesiccantDesiccantthatiseitherfresh(new)orhasbeenbakedaccordingtothemanufacturer’srecommendations
torenewittooriginalspecifications.
BarCodeLabelAlabelthatincludesinformationinacodeconsistingofparallelbarsandspacesora2-Dmatrixformat.
Note:Forthepurposeofthisstandard,thebarcodelabelisonthelowest-levelshippingcontainerandincludesinformationthat
describestheproduct,e.g.,partnumber,quantity,lotinformation,supplieridentification,andmoisture-sensitivitylevel.
BulkReflowReflowofmultipledeviceswithsimultaneousattachmentbyaninfrared(IR),convection/IR,convection,orvaporphasereflow(VPR)process.
Carrier Apockettape,tray,tube,orothercontainerusedtostoreandtransportpackageddevices.
DesiccantAnabsorbentmaterialusedtomaintainalowrelativehumidity.
FloorLifeTheallowabletimeperiodafterremovalofmoisture-sensitivedevicesfromamoisture-barrierbag,drystorage,ordrybakeandbeforethesolderprocess.
HumidityIndicatorCard(HIC)Acardonwhichamoisture-sensitivechemicalisappliedasaspotthatwillmakeasignificant,
perceptiblechangewhentheindicatedrelativehumidityisexceeded.
Note1:TwotypesofHICshavebeendefined.
Type1HIC(reversible)Forreversiblespotsthechangeistemporaryandoccursasachangeincolor(hue),typicallyfromblue(dry)topink(wet).Aperceptiblechangewillbeseenifthehumiditythresholdisonlymomentarilysurpassed.
Type2HIC(nonreversible)Fornonreversiblespotsthechangeisnottemporaryandcanbeaspotcolormigrationoutsideofthespotborderorsomeothernonreversibleindicator.AnonreversibleHICincludesatleasta60%RHindicatorspot,butcanhaveothernonreversibleRH%indicatorsthatdonotrevertafterexposuretoahumiditythreshold.
Note2:TheHICispackedinsidethemoisture-barrierbag,alongwithadesiccant,toaidindeterminingthelevelofmoisturetowhichthemoisture-sensitivedeviceshavebeensubjected.Type1andType2HICsthathavebeenexposedto60%orgreaterRHwillnolongerbeconsideredaccurate.
Manufacturer’sExposureTime(MET)Themaximumcumulativetimeafterbakethatdevicesmaybeexposedtoambientconditionspriortoshipmenttoenduser.
Moisture-BarrierBag(MBB)Abagdesignedtorestrictthetransmissionofwatervaporandusedtopackmoisture-sensitivedevices.
Moisture-SensitiveIdentification(MSID) Asymbolindicatingthatthecontentsaremoisture-sensitive.
Moisture-SensitivityLevel(MSL) Aratingindicatingadevice’ssusceptibilitytodamageduetoabsorbedmoisturewhen
subjectedtoreflowsolderingasdefinedinJ-STD-020.
ReworkTheremovalofadeviceforscrap,reuse,orfailureanalysis;thereplacementofanattacheddevice;ortheheatingandrepositioningofapreviouslyattacheddevice.
Process-SensitivityLevel(PSL)Aratingusedtoidentifyadevicethatissolder-process-sensitivebecausethedevice
cannotbeusedinoneormoreofthebasesolderprocessconditionsdefinedinJ-STD-075.
ShelfLife(ofadeviceinasealedMBB)Theallowabletimethatadry-packedmoistureorreflow-sensitivedevicecanbe
storedinanunopenedmoisture-barrierbag(MBB).
2
April2018 IPC/JEDECJ-STD-033D
SMDSurfacemountdevice.
Note:Forthepurposeofthisstandard,SMDisrestrictedtoincludeonlyplastic-encapsulatedSMDsandotherpackagesmadewithmoisture-permeablematerials.
SolderReflowAsolderattachmentprocessinwhichpreviouslyappliedsolderorsolderpasteismeltedtoattachadevicetoaprintedcircuitboard.
WaterVaporTransmissionRate(WVTR)Ameasureofthepermeabilityofplasticfilmormetallizedplasticfilmmaterial
tomoisture.
APPLICABLEDOCUMENTS(Normative)
AmericanSocietyforTestingandMaterials(ASTM)1
ASTMF1249StandardTestMethodforWaterVaporTransmissionRateThroughPlasticFilmandSheetingUsingaModulatedInfraredSensor.
ASTMF392StandardTestMethodforFlexDurabilityofFlexibleBarrierMaterials
ElectronicIndustriesAlliance(ECIA,ESDA,JEDEC)ANSI/ESDS541PackagingMaterialforESDSensitiveItems2
ANSI/ESDS541PackagingMaterialStandardsforESDSensitiveItems
JESD625RequirementsforHandlingElectrostaticDischargeSensitive(ESD)Devices
JEP160LongTermStorageGuidelinesforElectronicSolidStateWafers,Dice,andDevices
JESD22-A113PreconditioningofNon-hermeticSurfaceMountDevicesPriortoReliabilityTesting
JESD22-A120TestMethodfortheMeasurementofMoistureDiffusivityandWaterSolubilityinOrganicMaterialsUsedinIntegratedCircuits
IPCStandards3
IPC-7711/21Rework,ModificationandRepairofElectronicAssemblies
JointIndustryStandards4
J-STD-020Moisture/ReflowSensitivityClassificationforNon-hermeticSolidStateSurfaceMountDevicesJ-STD-075ClassificationofNon-ICElectronicComponentsforAssemblyProcesses
DepartmentofDefense5
MIL-PRF-81705TypeI-BarrierMaterialsFlexible.Electrostatic-free.HeatSealable
MIL-D-3464TypeII-Desiccant,Activated,Bagged,PackagingUseandStaticDehumidification
DRYPACKING
RequirementsDry-packingrequirementsforthevariousmoisturesensitivitylevelsareshowninTable3-1.ThelevelsaredeterminedperJ-STD-020,J-STD-075,and/orperJESD22-A113plusreliabilitytesting.AsaminimumallmaterialsusedindrypackingshouldconformtoANSI/ESDS541.
\h
;;
\h
\h
;;
\h
\h
/qsSearch.aspx
3
IPC/JEDECJ-STD-033D April2018
Table3-1Dry-PackingRequirements
Level
DryBeforeBag
MBBWithHIC
Desiccant
MSIDLabel
CautionLabel
1
Optional
Optional
Optional
NotRequired
NotRequiredifclassifiedat220oC–225oCRequired*ifclassifiedatotherthan220oC–225oC
2
Optional
Required
Required
Required
Required
2a-5a
Required
Required
Required
Required
Required
6
Optional
Optional
Optional
Required
Required
SocketOnly
NotApplicable
NotApplicable
NotApplicable
NotRequired
NotRequired
Note:*A‘‘Caution’’labelisnotrequirediflevelandreflowtemperaturearegiven,inhumanreadableform,onthebarcodelabelattachedtothelowestlevel
shippingcontainer.
DryingofSMDPackagesandCarrierMaterialsBeforeBeingSealedinMBBs
DryingRequirements-Levels2a-5aSMDpackagesclassifiedatLevels2athrough5amustbedried(seeClause4.)priortobeingsealedinMBBs.TheperiodbetweendryingandsealingmustnotexceedtheMETlessthetimeallowedfordistributorstoopenthebagsandrepackparts.Ifthesupplier’sactualMETismorethanthedefault24hours,thentheactualMETmustbeused.IfthedistributorpracticeistorepacktheMBBswithactivedesiccant,thenthistimedoesnotneedtobesubtractedfromtheMET.
DryingRequirementsforCarrierMaterialsCarriermaterials,suchastrays,tubes,reels,etc.,thatareplacedintheMBBcanaffectthemoisturelevelwithintheMBB.Therefore,theeffectofthesematerialsmustbecompensatedforbybakingor,ifrequired,addingadditionaldesiccantintheMBBtoensurethecalculatedshelflifeoftheSMDpackages.
DryingRequirementsSuppliersmayusethedryingeffectofnormalin-lineprocessessuchaspostmoldcure,markingcure,andburn-intoreducethebaketime.Anequivalencyevaluationisrecommendedtoensurethathightemperatureprocessingmaintainsmoistureweightgaintoanacceptablelevel.ThetotalweightgainfortheSMDpackageatthetimeitissealedintheMBBmustnotexceedthemoisturegainofthatpackagestartingdryandthenbeingexposedto30°C/60%RHforMEThours(lessthetimefordistributors).
ExcessTimeBetweenBakeandBagIftheallowabletimebetweenbakeandbagisexceeded,theSMDpackagesmustbedriedagainperClause4.
DryPack
J-STD-033D-3-1
MBB
DesiccantPouches
HIC
FoamEndCap
4
3
2
1
DescriptionDrypackconsistsofdesiccantmaterialandaHumidityIndicatorCard(HIC)sealedwiththeSMDpackagesinsideaMoistureBarrierBag(MBB).Arepresentativedry-packconfigurationisshowninFigure3-1.
Materials
MoistureBarrierBag(MBB)ThemoisturebarrierbagshallmeetMIL-PRF-81705,TYPEIrequirementsforflexibility,ESDprotection,mechanicalstrength,andpunctureresistance.Thebagsshallbeheatsealable.TheWaterVaporTransmissionRate(WVTR)shallbe
≤0.0310g/m2[0.002g/100in2]in24hoursat40°Cafterflextestingper
condition‘‘E’’ASTMF392.TheWVTRismeasuredusingASTMF1249.
DesiccantThedesiccantmaterialshallmeetMIL-D-3464,TYPEII.Desiccantshallbedustless,non-corrosive,andabsorbenttoamountsspecifiedinthestandard.Desiccanthasaverylimitedfloorlifeandshouldbestoredandhandledperthemanufacturer’srecommendation
priortoinsertionintheMBB.Thedesiccantmaterialshallbepackagedinmoisturepermeablebagsorpouches.Theamountofdesiccantused,permoisturebarrierbag,shallbebasedonthebagsurfaceareaandWVTRinordertolimittheinteriorrelativehumidityintheMBB,attheendofthecalculatedshelflife,tolessthan10%at25°C.
Figure3-1TypicalDry-PackConfigurationforMoisture-SensitiveSMDPackagesinShippingTubes
4
April2018 IPC/JEDECJ-STD-033D
Forcomparisonbetweenvariousdesiccanttypes,militaryspecificationsadoptedthe‘‘UNIT’’asthebasicunitofmeasureofquantityfordesiccantmaterial.AUNITofdesiccantisdefinedastheamountthatwillabsorbaminimumof2.85gofwatervaporat20%RHand25°C.
DesiccantQuantityCalculation
Whenthedesiccantcapacityat10%RHand25°Cisknown,thefollowingequationshouldbeused:
U=(0.304*M*WVTR*A)/D
Where:
U=AmountofdesiccantinUNITS
0.304=Averagenumberofdayspermonth/100in2(30.4/100)M=Shelflifedesiredinmonths(see3.3.6forshelflife)
WVTR=Watervaportransmissionrateingrams/m2[grams/100in2]in24hrsA=TotalexposedsurfaceareaoftheMBBinsquaredecimeters(squareinches)
D=Theamountofwateringrams,thataUNITofdesiccantwillabsorbat10%RHand25°C
Whenthedesiccantcapacityat10%RHand25°CisnotknownaconservativevalueofD=1.40canbeused.
Note1:Ifitisdesiredtominimizetheamountofdesiccantusedfordry-packinglevel2devicesavalueofDbasedontheamountofwateringrams,thataUNITofdesiccantwillabsorbat60%RHand25°Cmustbeusedintheformula.Thisvalueshouldtobeobtainedfromthedesiccantmanufacturer.WhenthisoptionisuseditmustbeverifiedthatwhenthedevicewasclassifiedperJ-STD-020itmusthaveachievedfullsaturationduringmoisturesoak.
Note2:Nomoisture-absorbingmaterial(e.g.,trays,tubes,reels,foamendcaps)shouldbeplacedinthedrybagwithoutlowtemperaturebaking.Anysuchmaterialthatisincludedincreasestheamountofdesiccantneededtomeetthecalculatedshelflife(see5.3.1)byanamountbasedonthemoisturecontentofthematerial.Thiscanbedeterminedbyweighingarepresentativequantityofmaterialknowntobeatequilibriumwiththemanufacturingenvironment,bakingtoanewconstantweight,andsubtractingthefinalfromtheinitialweight.
J-STD-033D-3-2B
J-STD-033D-3-2A
Donotputthiscardintoabagif60%isoverrun
5%
10%
PARTS
Bakepartsif10%isNOT
blueand5%ispink
Bakeparts
if60%overrunborder
REVERSIBLESPOTS
LEVEL2A-5A
60%
2PARTS
HUMIDITYINDICATOR
ComplieswithIPC/JEDECJ-STD-033
TYPE2NONREVERSIBLESPOT
LEVEL
Donotputthiscardintoabagif60%ispink
5%
10%
PARTS
Bakepartsif10%isNOT
blueand5%ispink
Bakeparts
if60%NOTblue
REVERSIBLESPOTS
LEVEL2A-5A
60%
2PARTS
HUMIDITYINDICATOR
ComplieswithIPC/JEDECJ-STD-033
TYPE1REVERSIBLESPOTS
LEVEL
LotNumber
LotNumber
AdditionalUNIT(s)ofdesiccant,basedon10%RH@25°C,mustbeaddedtoabsorbtheamountofwater,ingrams,egressedfromthepackingmaterials(dunnage)afterbaking.
ManufacturerIdentification
ManufacturerIdentification
Figure3-2AHumidityIndicatorCard(HIC)–Type1 Figure3-2BHumidityIndicatorCard(HIC)–Type2
5
IPC/JEDECJ-STD-033D April2018
DesiccantHandlingandStorageDesiccantcapacitydecreasesrapidlywhenexposedto30°C/60%RH.Thereforethedesiccantshouldremaininthemanufacturer’scontainerorstoredinadrycabinetat<5%RHuntiluse.Whendrypacking,thedesiccantshallberemovedfromthestoragecontainerjustpriortoplacingitintotheMBBandsealingtheMBB.AppendixCprovidesamethodtovalidatethedesiccantunitabsorptioncapacity.
HumidityIndicatorCards(HIC)Type1(Reversible)andType2(Nonreversible)Ataminimum,theHICshallhavethree
(3)colorspotswithsensitivityvaluesof5%,10%RHand60%RH.AnexampleType1HICiss
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 廣西物流職業(yè)技術(shù)學(xué)院《畜牧生產(chǎn)》2023-2024學(xué)年第二學(xué)期期末試卷
- 7-Ethoxy-4-methylcoumarin-Standard-生命科學(xué)試劑-MCE
- 四川郵電職業(yè)技術(shù)學(xué)院《無線傳感器網(wǎng)絡(luò)綜合實踐》2023-2024學(xué)年第二學(xué)期期末試卷
- 上海閔行職業(yè)技術(shù)學(xué)院《Python》2023-2024學(xué)年第二學(xué)期期末試卷
- 混凝土原材料采購合同范本
- 上海行健職業(yè)學(xué)院《測試信號與系統(tǒng)》2023-2024學(xué)年第二學(xué)期期末試卷
- 湖北恩施學(xué)院《汽車電子電氣A》2023-2024學(xué)年第二學(xué)期期末試卷
- 浙江藝術(shù)職業(yè)學(xué)院《環(huán)境工程施工技術(shù)》2023-2024學(xué)年第二學(xué)期期末試卷
- 2025-2030年中國船用密封裝置項目投資可行性研究分析報告
- 華僑大學(xué)《高中化學(xué)模塊研究》2023-2024學(xué)年第二學(xué)期期末試卷
- 外科學(xué)緒論課件
- 2020年中國人身保險產(chǎn)品研究報告
- 安全生產(chǎn)目標(biāo)責(zé)任制考核表
- 常見織帶花鏈的排法和穿棕方法
- 《化工工程制圖》完整教案
- 2023年廣東省中考試卷(語數(shù)英物化史生等共11套)帶答案解析
- DFX工藝設(shè)計方法介紹
- 洪恩識字識字卡(001-100)可直接打印剪裁
- 違反八項規(guī)定問題典型案例、法規(guī)依據(jù)和關(guān)注點
- 文聯(lián)述職報告
- SCI期刊的名稱縮寫與全稱對照表
評論
0/150
提交評論