1、in order to ensure normal teaching order, protecting students ' healthy growth, ensuring that national (property) is not lost, to prevent or minimize the occurrence of safety accidents, follow the "prevent, rescue each other, ensure safety and reduce losses" principle, according to the
2、 local conditions, make the management system. 1, the principal is the responsibility of school safety, school security under the leadership of president security work leading group. the head teacher to the leadership team is responsible for, implementation of the accountability system. 2, school mo
3、nthly student knowledge about safety education, education should be diversified in the form every safety education for students of classes per week should be targeted. to carry on emergency issues dealing with education in general, self-help and mutual rescue knowledge. emergency calls (such as 110,
4、 119, 122, 120, and so on) use common sense in education. 3, the establishment of major accident reporting system. school students report major accident within an hour of education; student run and disappearances to report; report of the accident to a written report in triplicate, a correctional cen
5、tre, a police station, a township people's government shall not conceal the accident. 4 week, teachers are on duty system, establish and improve the leadership values; strengthen the education, management of teaching activities in schools to ensure normal teaching order; responsible for school s
6、afety leadership always maintained close contact and district police stations, canvassing support from the police station on school safety and help. 5, strengthening teachers ' moral education, establish a dedicated love, improving education quality, observe the students ' psychological chan
7、ges at any time and take preventive measures, no corporal punishment and covert corporal punishment on students, student out of the classroom, schools may not be. 6, units or departments use student street propaganda or participate in the celebrations, as well as participating in other social work,
8、without approval of the correctional centre, school principals consent, without organization. without the approval of relevant departments, may organize students to participate in fire fighting, disaster relief and so on. 7, schools should educate students to obey the school rules and regulations, o
9、n time, on time home to prevent accidents. 8, school to school inspections on a regular basis, found hidden in time, and in severe cases, it is hard to eliminate immediately closed, and reported to the local people's government, education, and rule of law section. 9, the school should always che
10、ck the internal walls, retaining walls, ponds, railings, handrails, doors, windows, staircases and a variety of sports, extracurricular activities, facilities such as fire safety, infrastructure security, unsafe facility to immediately repair and demolition to ensure that teachers and students work,
11、 learn, live venues and facilities are safe and reliable. song lin xiang liu jia ping elementary school march 2016 song lin xiang liu jia ping primary school fire safety systems to enhance fire safety, protection of public property and the life and property safety of teachers and students, school fi
12、re safety into day-to-day management, is developing the following fire safety system. 1, strengthen fire safety education of the whole school. according to the requirements of the fire services act, so that everyone has of keeping fire control safety, protecting fire control facilities, fire prevent
13、ion, reports of fire工廠供電系統(tǒng)電氣部分設(shè)計(jì)二0一四年六月工廠供電系統(tǒng)電氣部分設(shè)計(jì) 田文杰(供電12833) 摘 要 工廠供電(electric power supply for indusrial plants),就是指工廠所需電能的供應(yīng)和分配問題,眾所周知,電能是現(xiàn)代工業(yè)生產(chǎn)的主要能源和動(dòng)力。電能既易于由其他形式能量轉(zhuǎn)換而來,又易于轉(zhuǎn)換為其他形式的能量已供應(yīng)用;它的輸送與分配既簡(jiǎn)單經(jīng)濟(jì),又便于控制、調(diào)節(jié)和測(cè)量,有利于實(shí)現(xiàn)生產(chǎn)過程自動(dòng)化。因此,電能在現(xiàn)代工業(yè)生產(chǎn)及整個(gè)國民經(jīng)濟(jì)生活中應(yīng)用極為廣泛。 在工廠里,電能雖然是工業(yè)生產(chǎn)的
14、主要能源和動(dòng)力,但是它在生產(chǎn)成本中所占的比重一般很小。例如在機(jī)械工業(yè)中,電能開支占產(chǎn)品成本的5%左右。從投資額來看,有些機(jī)械工廠在供電設(shè)備上的投資也僅占總投資的5%左右。所以電能在工業(yè)生產(chǎn)中的重要性,并不在與它在產(chǎn)品成本中或投資總額中所占的比重多少,而在于工業(yè)生產(chǎn)實(shí)現(xiàn)電氣化以后,可以大大增加產(chǎn)量,提高產(chǎn)品質(zhì)量,提高勞動(dòng)生產(chǎn)率,降低生產(chǎn)成本,減輕工人的勞動(dòng)強(qiáng)度,改善工人的勞動(dòng)條件,有利于實(shí)現(xiàn)生產(chǎn)過程自動(dòng)化。從另一方面來說,如果工廠的電能供應(yīng)突然中斷,則對(duì)工業(yè)生產(chǎn)可能造成嚴(yán)重后果。例如某些對(duì)供電可靠性要求很高的電廠,即使是極短時(shí)間的停電,也會(huì)引起重大設(shè)備的損壞,或引起大量產(chǎn)品報(bào)廢,甚至可能發(fā)生重大
15、的人生事故,給國家和人民帶來經(jīng)濟(jì)甚至政治上的重大損失。 因此,搞好工廠供電工作對(duì)于發(fā)展工業(yè)生產(chǎn),實(shí)現(xiàn)工業(yè)現(xiàn)代化,具有十分重要的意義,而能源節(jié)約對(duì)于國家經(jīng)濟(jì)建設(shè)是一項(xiàng)具有戰(zhàn)略意義工作,也是工廠供電工作的一項(xiàng)重要任務(wù)。 工廠供電工作要很好地圍攻業(yè)生產(chǎn)服務(wù),切實(shí)保證工廠生活和生活用電的需要,并搞好能源節(jié)約,就必須達(dá)到以下基本要求1安全在電能的供應(yīng)、分配和使用中,不應(yīng)發(fā)生人身事故或設(shè)備事故。2可靠應(yīng)滿足電能用戶對(duì)供電可靠性的要求3優(yōu)質(zhì)應(yīng)滿足電能用戶對(duì)電壓量和頻率等方面的要求4經(jīng)濟(jì)供電系統(tǒng)的投資要少,運(yùn)行費(fèi)用要低
16、,并盡可能地節(jié)約電能和減少有色金屬消耗量。 此外,在供電工作中,應(yīng)合理地處理局部、當(dāng)前和長(zhǎng)遠(yuǎn)等關(guān)系,既要照顧局部和當(dāng)前利益,又要有全局觀點(diǎn),能顧全大局,適應(yīng)發(fā)展。關(guān)鍵詞:負(fù)荷計(jì)算,三相短路,主接線,繼電保護(hù),設(shè)備選擇1 變壓器的選擇及其電氣主接線 1.1變壓器的選擇 1.1.1電力變壓器及其分類 電力變壓器是變電所中最關(guān)鍵的一次設(shè)備,其主要功能是將電力系統(tǒng)的電能電壓升高或降低,以利于電能的合理輸送、分配和使用。 常用變壓器的種類,在中低壓供配電系統(tǒng)中,常用的電力變壓器有如下幾種分類方式: 按相數(shù)分類:有三相電力
17、變壓器和單相電力變壓器。大多數(shù)場(chǎng)合使用三相電力變壓器,在一些低壓?jiǎn)蜗嘭?fù)載較多的場(chǎng)合,也使用單相變壓器。 按繞組導(dǎo)電材料分類:有銅繞組變壓器和鋁繞組變壓器,目前一般采用銅繞組變壓器。 按絕緣介質(zhì)分類:有油浸式變壓器和干式變壓器兩大類。 按繞組聯(lián)結(jié)組別分類:有yyn0和dyn11兩種。 1.1.2電力變壓器的連接組別電力變壓器的聯(lián)結(jié)組別,是指變壓器一、二次繞組因采取不同的聯(lián)結(jié)方式而形成變壓器一、二次側(cè)對(duì)應(yīng)的線電壓之間不同相位關(guān)系。 中壓配電變壓器有yyn0,和dyn11兩種常見的聯(lián)結(jié)組,配電變壓器用dyn11聯(lián)結(jié)
18、。較之采用yyn0聯(lián)結(jié)有一下優(yōu)點(diǎn): 對(duì)dyn11聯(lián)結(jié)變壓器來說,其3n次諧波電流在其三角形接線的一次繞組內(nèi)形成環(huán)流,從而不致注入公共的高壓電網(wǎng)中去,這交之一次繞組接成星形接線的yyn0聯(lián)結(jié)變壓器更有利于抑制高次諧波電流。 dyn11聯(lián)結(jié)變壓器的零序阻抗較之yyn0聯(lián)結(jié)變壓器的零序阻抗小的多,從而更有利于低壓?jiǎn)蜗嘟拥毓收媳Wo(hù)的動(dòng)作和故障的切除。 當(dāng)?shù)蛪簜?cè)接用單相不平衡負(fù)荷時(shí),由于yyn0聯(lián)結(jié)變壓器要求低壓中性線電流不超過低壓繞組額定電流的25%,因而嚴(yán)重限制了其接用單相負(fù)荷的容量,影響了變壓器設(shè)備能力的發(fā)揮。 gb
19、60;50052-1995供配電系統(tǒng)設(shè)計(jì)規(guī)范規(guī)定,低壓為tn及tt系統(tǒng)時(shí),宜與選用dyn11聯(lián)結(jié)變壓器。dyn11聯(lián)結(jié)變壓器的低壓側(cè)中性線電流允許達(dá)到低壓繞組額定電流的75%以上,其承受單相不平衡負(fù)荷的能力遠(yuǎn)比yyn0聯(lián)結(jié)變壓器大。 因此,機(jī)器廠的電力變壓器選擇dyn11聯(lián)結(jié)形式。1.1.3變壓器臺(tái)數(shù)和容量的選擇 1、選擇主變壓器臺(tái)數(shù)應(yīng)考慮下列原則: 1) 三級(jí)負(fù)荷一般設(shè)一臺(tái)變壓器,但考慮現(xiàn)有開關(guān)設(shè)備開斷容量的限制,所選單臺(tái)變壓器的容量一般不大于1250kva;當(dāng)用電負(fù)荷所需的變壓器容量大于1250kva時(shí),通常應(yīng)采用兩臺(tái)或更多臺(tái)變壓器。 2)
20、 當(dāng)季節(jié)性或晝夜性的負(fù)荷較多時(shí),可將這些負(fù)荷采用單獨(dú)的變壓器供電,以便這些負(fù)荷不投入使用時(shí),切除相應(yīng)的供電變壓器,減少空載損耗。 3) 當(dāng)有較大的沖擊性負(fù)荷時(shí),為避免對(duì)其他負(fù)荷供電質(zhì)量的影響,可單獨(dú)設(shè)變壓器對(duì)其供電。 4) 當(dāng)有大量一、二級(jí)負(fù)荷時(shí),為保證供電可靠性,應(yīng)設(shè)兩臺(tái)或多臺(tái)變壓器。以起到相互備用的作用。 5) 在確定變電所住變壓器臺(tái)數(shù)時(shí),應(yīng)考慮負(fù)荷的發(fā)展,留有一定的余量。2、變壓器容量的選擇: 1)只裝一臺(tái)主變壓器的變電所 主變壓器容量sn.t應(yīng)滿足全部用電設(shè)備總計(jì)算負(fù)荷s30的需求,即
21、sn.s30 式(1.1) 2) 裝有兩臺(tái)主變壓器的變電所,每臺(tái)變壓器的容量sn.t應(yīng)該同時(shí)滿足以下兩個(gè)條件: a.任一臺(tái)變壓器單獨(dú)運(yùn)行時(shí),宜滿足總的計(jì)算負(fù)荷s30的大約60%-70%的需要,即 sn.t =(0.6 0.7) s30 式(1.2) b.任一臺(tái)變壓器單獨(dú)運(yùn)行時(shí),應(yīng)滿足全部一、二級(jí)負(fù)荷的要求。即 +p³ &
22、#160; sn.t s30(+) 式(1.3) 3、車間變電所主變壓器的單臺(tái)容量上限: 車間變電所主變壓器的單臺(tái)容量,一般不宜大于1000kva。這一方面是受以往低壓開關(guān)電器斷流能力和短路穩(wěn)定度要求的限制,另一方面也是考慮到可以使變壓器更接近于車間負(fù)荷中心,以減少低壓配電線路的電能損耗、電壓損耗和有色金屬消耗量。 4、適當(dāng)考慮負(fù)荷的發(fā)展 應(yīng)適當(dāng)考慮今后510年電力負(fù)荷的增長(zhǎng),留有一定的余地。
23、 1.1.4電力變壓器的校驗(yàn) 電力變壓器的額定容量sn.t是在一定溫度條件下的持續(xù)最大輸出容量。如果安住地點(diǎn)的年平均氣溫 0.av20q時(shí),則年平均氣溫每升高1°c,變壓器容量相應(yīng)地減少1%,戶外電力變壓器的實(shí)際容量為 st=(1-0.av-20/100)sn.t 式(1.4)對(duì)于戶內(nèi)變壓器,由于散熱條件差,一般變壓器室的出風(fēng)口與進(jìn)風(fēng)口間有約15°c的溫差,從而使處于室內(nèi)中間的變壓器環(huán)境溫度比戶外變壓器環(huán)境溫度要高出大約8°c,因此戶內(nèi)變壓器的實(shí)際容量較之上式所計(jì)算的容量還要小8%。 對(duì)于s9-630/10型變壓器,考慮本地年平均氣溫
24、為23.2°c,即年平均氣溫不等于20°c,對(duì)于室內(nèi)變壓器,其實(shí)際容量為 st=(0.92-0.av-20/100)sn.t=(0.92-(23.2-20/100)630kva =599.44kva425.16kva因此,選擇的變壓器滿足要求。1.2工廠變配電所的主接線圖 1.2.1電氣主接線的概況 電氣主接線圖即主電路圖,是表示供電系統(tǒng)中電能輸送和分配線路的電路圖,亦稱一次電路圖。它的設(shè)計(jì),直接關(guān)系著全廠電氣設(shè)備的選擇、配電裝置的布置、繼電保護(hù)和自動(dòng)裝置的確定,關(guān)系著電力系統(tǒng)的安全、穩(wěn)定、靈活和經(jīng)濟(jì)運(yùn)行。 電氣主接線應(yīng)滿足可靠性、
25、靈活性和經(jīng)濟(jì)性三方面: 可靠性:為了向用戶供應(yīng)持續(xù)、優(yōu)質(zhì)的電力,電氣主接線首先必須滿足這一可靠性的要求。主接線的可靠性的衡量標(biāo)準(zhǔn)是運(yùn)行實(shí)踐,要充分地做好調(diào)研工作,力求避免決策失誤,鑒于進(jìn)行可靠的定量計(jì)算分析的基礎(chǔ)數(shù)據(jù)尚不完善的情況,充分做好調(diào)查研究工作顯的尤為重要。 為了提高主接線的可靠性,選用運(yùn)行可靠性高的設(shè)備是條捷徑,這就要兼顧可靠性和經(jīng)濟(jì)性兩方面,做出切合實(shí)際的決定。 靈活性:電氣主接線應(yīng)能適應(yīng)各種運(yùn)行狀態(tài),并能靈活地進(jìn)行運(yùn)行方式的轉(zhuǎn)換。靈活性包括以下幾個(gè)方面: 1)操作的方便性 電氣主接線應(yīng)該在服從可靠性的基本要
26、求條件下,接線簡(jiǎn)單,操作方便,盡可能地使操作步驟少,以便于運(yùn)行人員掌握,不致在操作過程中出差錯(cuò)。 2)調(diào)度的方便性 電氣主接線在正常運(yùn)行時(shí),要根據(jù)調(diào)度要求,方便的改變運(yùn)行方式。并且發(fā)生事故時(shí),要能盡快地切出故障,故停電時(shí)間最短,影響范圍最小,不致過多地影響對(duì)用戶的供電和破壞系統(tǒng)的穩(wěn)定運(yùn)行。 3)擴(kuò)建的方便性 對(duì)將來要擴(kuò)建的發(fā)電廠和變電站,其主接線必須具有擴(kuò)建的方便性。 經(jīng)濟(jì)性:采用簡(jiǎn)單的接線方式,少用設(shè)備,節(jié)省設(shè)備上的投資。1.2.2車間和小型工廠變電所的主接線圖 1、車間變電所的主接線
27、圖 車間變電所的主接線分兩種情況: 1) 有工廠總降壓變電所或高壓配電所的車間變電所 其高壓側(cè)的開關(guān)電器、保護(hù)裝置和測(cè)量?jī)x表等,一般都安裝在高壓配電線路的首段,即總配電所的高壓配電室內(nèi),而車間變電所只設(shè)變壓器室和低壓配電室,其高壓側(cè)多數(shù)不安裝開關(guān),或只安裝簡(jiǎn)單的隔離開關(guān)、熔斷器、避雷器等,如圖1.1所示。圖1.1 車間變電所高壓側(cè)主接線方案 a)高壓電纜進(jìn)線,無開關(guān) b)高壓電纜進(jìn)線,裝隔離開關(guān) c)高壓電纜進(jìn)線,裝隔離開關(guān)-熔斷器 d)高壓電纜進(jìn)線,裝負(fù)荷開關(guān)-熔斷器 e)高壓架空
28、進(jìn)線,裝跌開式熔斷器和避雷器 f)高壓架空進(jìn)線,裝隔離開關(guān)-熔斷器和避雷器g)高壓架空線,裝隔離開關(guān)-熔斷器和避雷器 由圖可以看出,凡是高壓架空進(jìn)線,變電所高壓側(cè)必須裝設(shè)避雷器,以防雷電波沿著架空線路侵入變電所擊毀電力變壓器及其他設(shè)備的絕緣。而采用高壓電纜進(jìn)線時(shí),避雷器則裝設(shè)在電纜的首端,而且避雷器的接地端要連同電纜的金屬外皮一起接地。此時(shí)變壓器高壓側(cè)一般可以不再裝設(shè)避雷器。如果變壓器高壓側(cè)為架空線又經(jīng)過一段電纜引入時(shí),則變壓器高壓側(cè)仍應(yīng)裝設(shè)避雷器。 2)工廠無總變、配電所的車間變電所 工廠內(nèi)無總降壓變電所和高壓配電所時(shí),其車間變電所往往就是工廠的降壓變電所,其高壓側(cè)的開關(guān)
29、電器、保護(hù)裝置和測(cè)量?jī)x表等,都必須配備齊全,所以一般要設(shè)置高壓配電室。在變壓器容量較小、供電可靠性要求不高的情況下,就可以不設(shè)高壓配電室,其高壓側(cè)的開關(guān)電器就裝在變壓器室的墻上或電桿上,而在低壓側(cè)計(jì)量電能,或者其高壓柜就裝在低壓配電室內(nèi),在高壓側(cè)計(jì)量電能。 2、小型工廠變電所的主接線圖 1)只裝有一臺(tái)主變壓器的小型變電所主接線圖 只裝有一臺(tái)主變壓器的小型變電所,其高壓側(cè)一般采用無母線的接線。根據(jù)其高壓側(cè)采用的開關(guān)電器不同,有以下三種比較經(jīng)典的主接線方案。 a. 高壓側(cè)采用隔離開關(guān)-熔斷器或戶外跌開式熔斷器的變電所主接線圖(圖1.2)這種主接線,受隔
30、離開關(guān)和開式熔斷器切斷空載變壓器容量的限制,一般只用于500kva及以下容量的變電所。圖1.2 高壓側(cè)采用隔離開關(guān)-熔斷器 圖1.3 高壓側(cè)采用負(fù)荷開關(guān)-熔斷器或跌開式熔斷器的變電所主接線圖 或負(fù)荷跌開式熔斷器的變電所直接線圖這種變電所相當(dāng)簡(jiǎn)單經(jīng)濟(jì),但供電可靠性不高,當(dāng)主變壓器或高于側(cè)停電檢修或發(fā)生故障時(shí),整個(gè)變電所要停電。由于隔離開關(guān)和跌開式熔斷器不能帶負(fù)荷操作,因此變電所送電和停電的操作程序比較復(fù)雜,如果稍有疏忽,還容易發(fā)生帶負(fù)荷拉閘的嚴(yán)重事故,而且在熔斷器熔斷后,更換熔體需一定時(shí)間,從而影響供電的可靠性。但是這種主接線簡(jiǎn)單經(jīng)濟(jì),對(duì)于三級(jí)負(fù)荷的小容量變電所是相當(dāng)適宜的。
31、b.高壓側(cè)采用負(fù)荷開關(guān)-熔斷器或負(fù)荷跌開式熔斷器的變電所主接線圖(圖1.3) 由于負(fù)荷開關(guān)和負(fù)荷跌開式熔斷器能帶負(fù)荷操作,從而使變電所停、送電的操作簡(jiǎn)便靈活得多,也不存在著在帶負(fù)荷拉閘的危險(xiǎn)。但在發(fā)生短路故障時(shí),只能是熔斷器熔斷,因此這種主接線仍然存在著在排除短路故障時(shí)恢復(fù)供電的時(shí)間較長(zhǎng)的缺點(diǎn),供電可靠性仍然不高,一般也只用于三級(jí)負(fù)荷的變電所。圖1.4 高壓側(cè)采用隔離開關(guān) 圖1.5 高壓雙回路進(jìn)線的一臺(tái)主-斷路器的變電所主接線圖 變壓器變電所主接線圖 c.高壓側(cè)采用隔離開關(guān)-斷路器的變電所主接線圖(圖1.4) 這種主接線由于采用了高壓斷路器,因
32、此變電所的停、送電操作十分靈活方便,而且在發(fā)生短路故障時(shí),過電流保護(hù)裝置動(dòng)作,斷路器會(huì)自動(dòng)跳閘,如果短路故障已經(jīng)消除,則可立即合閘回復(fù)供電。如果配備自動(dòng)重合閘裝置,則供電可靠性更高。但是如果變電所只此一路電源進(jìn)線時(shí),一般也只用于三級(jí)負(fù)荷;但如果變電所低壓側(cè)有聯(lián)絡(luò)線與其他變電所相連時(shí),或另有備用電源時(shí),則可用于二級(jí)負(fù)荷。如果變電所有兩路電源進(jìn)線,如圖1.5所示,則供電可靠性相當(dāng)提高,可供二級(jí)負(fù)荷或少量一級(jí)負(fù)荷。圖1.6 高壓側(cè)無母線、低壓側(cè)單母分段的變電所主接線圖2)裝有兩臺(tái)主變壓器的小型變電所主接線圖 a.高壓無母線、低壓?jiǎn)文妇€分段的變電所主接線圖(圖1.6) &
33、#160;這種主接線的供電可靠性較高,當(dāng)任一主變壓器或任一電源進(jìn)線停電檢修或發(fā)生故障時(shí),該變電所通過閉合低壓母線分段開關(guān),即可迅速恢復(fù)對(duì)整個(gè)變電所的供電。如果兩臺(tái)主變壓器高壓側(cè)斷路器裝設(shè)互為備用的備用電源自動(dòng)投入裝置,則任一主變壓器高壓側(cè)斷路器因電影斷電而跳閘時(shí),另一主變壓器高壓側(cè)的斷路器在備用電源自動(dòng)投入裝置作用下自動(dòng)合閘,恢復(fù)整個(gè)變電所的供電。這時(shí)變電所可供一、二級(jí)負(fù)荷。圖1.7 高壓采用單母線、低壓?jiǎn)文妇€分段的變電所主接線 b.高壓側(cè)采用單母線、低壓側(cè)采用單母分段的變電所主接線圖(圖1.7) 這種主接線適用于裝有兩臺(tái)及以上主變壓器或具有多路高壓出
34、線的變電所,其供電可靠性也較高。任一主變壓器檢修或發(fā)生故障是,通過切換操作,即可迅速恢復(fù)對(duì)整個(gè)變電所的供電。但是高壓母線或電源進(jìn)線進(jìn)線檢修或發(fā)生故障時(shí),整個(gè)變電所仍要停電。這時(shí)只能供電給三級(jí)負(fù)荷。如果有與其他變電所相連的高壓或低壓聯(lián)絡(luò)線時(shí),則可供一、二級(jí)負(fù)荷。 c.高低壓側(cè)均采用單母線分段的變電所主接線圖(圖1.8) 這種主接線的兩段高壓母線,在正常時(shí)可以接通運(yùn)行,也可以分段運(yùn)行。任一臺(tái)主變壓器或任一路電源進(jìn)線停電檢修或發(fā)生故障時(shí),通過切換操作,均可迅速恢復(fù)整個(gè)變電所的供電。因此,其供電可靠性相當(dāng)高,可供一、二級(jí)負(fù)荷。圖1.8 高低壓側(cè)均為單母線分段的
35、變電所主接線圖2 短路電流的計(jì)算 2.1短路的原因、后果及其形式 2.1.1短路的原因 系統(tǒng)中最常見的故障就是短路,短路就是指不同電位的導(dǎo)電部分對(duì)地之間的低阻性短接。產(chǎn)生短路的原因有: 電氣設(shè)備絕緣被損壞 絕緣損壞多由于未及時(shí)發(fā)現(xiàn)和消除設(shè)備的缺陷,以及設(shè)計(jì)、安裝和運(yùn)行維護(hù)不良所致。例如,過電壓、設(shè)備遭雷擊、絕緣材料陳舊、機(jī)械損傷等等。 有關(guān)人員誤操作 這種情況大多是由于操作人員違反安全操作規(guī)程而發(fā)生的,例如帶負(fù)荷拉閘,或者誤將低電壓設(shè)備接入較高電壓的電路中而造成擊穿短路。 鳥獸為害事故 鳥獸跨
36、越在裸露的相線之間或者相線與接地物體之間,或者咬壞設(shè)備和導(dǎo)線電纜的絕緣,從而導(dǎo)致短路。 2.1.2短路的后果 短路后,系統(tǒng)中出現(xiàn)的短路電流比正常負(fù)荷電流大得多。在大電力系統(tǒng)中,短路電流可達(dá)幾萬安甚至幾十萬安。短路電流對(duì)系統(tǒng)產(chǎn)生較大的危害: 短路時(shí)要產(chǎn)生很大的點(diǎn)動(dòng)力和很高的溫度,而使故障元件和短路電路中的其他元件受到損害和破壞,甚至引發(fā)火災(zāi)事故。 短路時(shí)電路的電壓驟降,嚴(yán)重影響電氣設(shè)備的正常運(yùn)行。 短路時(shí)保護(hù)裝置動(dòng)作,將故障電路切除,從而造成停電,而且短路點(diǎn)越靠近電源,停電范圍越大,造成的損失也越大。
37、0;嚴(yán)重的短路要影響電力系統(tǒng)運(yùn)行的穩(wěn)定性,可使并列運(yùn)行的發(fā)電機(jī)組失去同步,造成系統(tǒng)結(jié)列。 不對(duì)稱短路包括單相和兩相短路,其短路電流將產(chǎn)生較強(qiáng)的不平衡交變電磁場(chǎng),對(duì)附近的通信線路、電子設(shè)備等產(chǎn)生電磁干擾,影響其正常運(yùn)行,甚至使之發(fā)生誤動(dòng)作。 由此可見,短路的后果是十分嚴(yán)重的,因此必須盡力設(shè)法消除可能引起短路的一切因素;同時(shí)需要進(jìn)行短路電流的計(jì)算,以便正確地選擇電氣設(shè)備,使設(shè)備具有足夠的動(dòng)穩(wěn)定性和熱穩(wěn)定性,以保證在發(fā)生可能有的最大短路電流時(shí)不致?lián)p壞。為了選擇切除短路故障的開關(guān)電器、整定短路保護(hù)的繼電裝置和選擇限制短路電流的元件(如電抗器)等,也必須計(jì)算短路電流。2
38、.1.3短路的形式 在三相系統(tǒng)中,短路的形式有三相短路、兩相短路、單相短路和兩相接地短路等,其中兩相接地短路,實(shí)質(zhì)是兩相短路。 按短路電路的對(duì)稱性來分,三相短路屬于對(duì)稱性短路,其他形式短路均不為對(duì)稱短路。 電力系統(tǒng)中,發(fā)生單相短路的可能性最大,而發(fā)生三相短路的可能性最小。但一般情況下,特別是遠(yuǎn)離電源的工廠供電系統(tǒng)中,三相短路的短路電流最大,因此造成的危害也最為嚴(yán)重。為了使電力系統(tǒng)中的電氣設(shè)備在最嚴(yán)重的短路狀態(tài)下也能可靠的工作,因此作為選擇和校驗(yàn)電氣設(shè)備用的短路計(jì)算中,以三相短路計(jì)算為主。實(shí)際上,不對(duì)稱短路也可以按對(duì)稱的短路電流分解為對(duì)稱的正序、負(fù)序、零序分量,然
39、后按對(duì)稱量來分析和計(jì)算,所以對(duì)稱的三相短路分析計(jì)算也是不對(duì)稱短路分析計(jì)算的基礎(chǔ)。 2.2無限大容量電力系統(tǒng)的三相短路計(jì)算 2.2.1無限大容量電力系統(tǒng) 無限大容量電力系統(tǒng),是指供電容量先對(duì)于用戶供電系統(tǒng)容量大的多的電力系統(tǒng)。其特點(diǎn)是:當(dāng)用戶供電系統(tǒng)的負(fù)荷變動(dòng)甚至發(fā)生短路時(shí),電力系統(tǒng)變電所饋電母線上的電壓能基本維持不變。如果電力系統(tǒng)的電源總阻抗不超過短路總阻抗的5%-10%,或者電力系統(tǒng)容量超過用戶供電系統(tǒng)容量的50倍時(shí),可將電力系統(tǒng)視為無限大容量系統(tǒng)。 對(duì)一般工廠供電系統(tǒng)來說,由于工廠供電系統(tǒng)的容量遠(yuǎn)比電力系統(tǒng)總?cè)萘啃?,而阻抗又較電力系統(tǒng)大
40、得多,因此工廠供電系統(tǒng)內(nèi)發(fā)生短路時(shí),電力系統(tǒng)變電所饋電母線上的電壓幾乎維持不變,也就是說可將電力系統(tǒng)視為無限大容量的電源。 2.2.2短路電流的計(jì)算方法 進(jìn)行短路電流計(jì)算,首先要繪出計(jì)算電路圖,在電路圖上,將短路計(jì)算所需要考慮的各元件的額定參數(shù)都表示出來,并將個(gè)元件依次編號(hào),然后確定短路計(jì)算點(diǎn)。短路計(jì)算點(diǎn)要選擇得使需要進(jìn)行短路校驗(yàn)的電氣元件有最大可能的短路電流通過。 電力系統(tǒng)的阻抗計(jì)算 電力系統(tǒng)的電阻相對(duì)于電抗來說很小,一般不予考慮。電力系統(tǒng)的電抗,可由電力系統(tǒng)變電站饋電線出口斷路器的斷路容量soc來估算,電力系的電抗為 xs=uc2/
41、soc 式(2.1)式中,uc為電力系統(tǒng)饋電線的短路計(jì)算電壓,但為了便于短路電路總阻抗的計(jì)算,免去阻抗換算的麻煩,此式中的uc可直接采用短路點(diǎn)的短路計(jì)算電壓;soc為系統(tǒng)出口斷路器的斷流容量,如果只有斷路器的開斷電流ioc,則其斷流容量soc=iocun,這里的un為斷路器的額定電壓。 電力變壓器的阻抗計(jì)算 1)變壓器的電阻rt 可由變壓器的短路損pkd耗近似計(jì)算因pk 3in2rt=(sn/uc)2 rt 故rtpk(uc / sn)2 式(2.2) 式中,uc為短路點(diǎn)短路計(jì)算電壓;sn為變壓器的額定容量;pkd為變
42、壓器的短路損耗。 2)變壓器的電抗xt 可由變壓器的短路電壓uk 近似地計(jì)算。因 uk snxt/uc2×100故 xt(uk /100)×(uc2/sn) 式(2.3)式中,uk 為變壓器的短路電壓百分值。 電力線路的阻抗計(jì)算 1)線路的電阻rwl可由導(dǎo)線電纜的單位長(zhǎng)度電阻r0乘以線路長(zhǎng)度求得,即 rwl=r01 式(2.4)式中,ro為導(dǎo)線電纜單位長(zhǎng)度電阻,l為線路長(zhǎng)度。2)線路的電抗xwl可由導(dǎo)線電纜的單位長(zhǎng)度電抗x0乘以線路長(zhǎng)度求得,即 xwl=x01 式(4.5)表2.1 電力線路每相的單
43、位長(zhǎng)度電抗平均值線路結(jié)構(gòu) 線路電壓35kv及以上6-10kv220v/380v架空線路0.40.350.32電纜線路0.120.080.066在計(jì)算短路電路的阻抗時(shí),假如電路內(nèi)含有電力變壓器時(shí),電路內(nèi)各元件的阻抗都應(yīng)該統(tǒng)一換算到短路點(diǎn)的短路計(jì)算電壓去,阻抗等效換算的條件是元件的功率損耗不變。2.2.3工廠三相短路電流的計(jì)算 畫出短路計(jì)算電路圖,如圖2.1所示:圖2.1 短路計(jì)算電路圖畫出短路等效電路圖,如圖2.2所示:圖2.2 短路等效電路圖 求短路點(diǎn)k-1處短路電流和短路容量(ucl=10.5kv=)。 1) 計(jì)算短路電路中各元件的
44、電流和總阻抗。 a.電力系統(tǒng)的電抗: xl=ucl2/soc=(10.5kv)2/500mva=0.221查表得sn10-10型斷路器的斷流容量soc=500mvab架空線路的電抗:x2=x01=0.35×1=0.35c電纜線路的電抗:x3=x(01)11=0.08×0.02=0.0016計(jì)算總電抗: x(k-1)=x1+x2+x3=0.5732) 計(jì)算k-1點(diǎn)的三相短路電流和短路容量。 三相短路次暫態(tài)電流和穩(wěn)態(tài)電流: i(3)sh(k-1)=2.55i(k-1)(3)=2.55×10.58=26.976kvai(3)sh(
45、k-1)=1.51i(k-1)(3)=1.51×10.58=15.976kva求k-2點(diǎn)三相短路電流和短路容量(uc2=0.4kv)1)計(jì)算短路電路中各元件的電抗和總電抗 a電力系統(tǒng)的電抗:x1=u2c2/soc=0.42/500=3.2×10-4b架空線路的電抗:x2=x01(uc2/uc1)2=0.35×(0.4/10.5)2=5.08×10-4c電纜線路的電抗:x3=x(01)11(uc2/uc1)2=0.0016×(0.4/10.5)2=2.32×10-6d電力變壓器的電抗:查表uk=5則x4=( uk/100)
46、215;(u2c2/sn)=(5/100)×(0.42/630)=0.0127總電抗x(k-1)= x1+ x2+ x3+ x4=0.01353) 計(jì)算k-2點(diǎn)三相短路電流和短路容量。三相次暫態(tài)短路電流和短路穩(wěn)態(tài)電流 i(k-2)(3)=i(k-2)(3) = i(3)(k-2)=17.11ka三相短路沖擊電流及第一個(gè)周期短路全電流有效值:i(3)sh(k-2)=1.84i(k-2)(3)=1.84×17.11=31.48kva3.主要設(shè)備選擇3.1導(dǎo)線的選擇與校驗(yàn) 3.1.1車間導(dǎo)線截面及配電箱的選擇1. 選擇配電箱中各路的熔體額定電流。根據(jù)
47、設(shè)備明細(xì)表中各設(shè)備的容量,依據(jù)熔斷器的選擇方法和原則,可得出各路的熔體額定電流。 2. 根據(jù)已選出的各路熔體額定電流,并預(yù)留1-2路(將來增加用電設(shè)備時(shí)可不更換分電箱)。確定線路數(shù)和熔斷器電流相適應(yīng)的分電箱。 3. 根據(jù)已選出的各路熔體電流及其敷設(shè)方式、環(huán)境溫度等,依據(jù)導(dǎo)線及電線管得選擇方法和原則,可選出相應(yīng)的導(dǎo)線及電線管。 4. 引入配電箱分干線截面的選擇。由于每小分電箱所接的設(shè)備臺(tái)數(shù)不多,所以分干線的計(jì)算電流應(yīng)按二項(xiàng)式法計(jì)算。這樣才能照顧到大容量設(shè)備對(duì)計(jì)算機(jī)電流的影響。 選干線截面時(shí),應(yīng)留有余量,以備負(fù)荷發(fā)展。干線導(dǎo)線有兩部分組成
48、:一部分是敷設(shè)在車間的明敷部分,按明敷設(shè)選導(dǎo)線;另一部分是從配電箱引到干線小于2m要加保護(hù)措施,采用穿管敷設(shè),應(yīng)按穿管導(dǎo)線選擇導(dǎo)線。選總線干線時(shí),每路干線所接設(shè)備臺(tái)數(shù)不多,干線的計(jì)算電流也應(yīng)按二項(xiàng)式法計(jì)算。3.2高壓一次設(shè)備的選擇:3.2.1一次設(shè)備及其分類 變電所中承擔(dān)輸送和分配電能的任務(wù)電路,稱為一次電路,一次電路中的所有設(shè)備,稱為一次設(shè)備。 一次設(shè)備按其功能來分,可分為以下幾類: 1. 變換設(shè)備 其功能是按電力系統(tǒng)運(yùn)行的要求改變電壓或電流、頻率等,例如電力變壓器、電壓互感器、電力互感器、變頻機(jī)等。 2.控制設(shè)備
49、160; 其功能是按電力系統(tǒng)運(yùn)行的要求來控制一次設(shè)備的通、斷,例如各種高低壓開關(guān)設(shè)備。 3. 保護(hù)設(shè)備 其功能是用來對(duì)電力系統(tǒng)進(jìn)行過電流和過電壓等的保護(hù),例如熔斷器和避雷器等。 4. 補(bǔ)償設(shè)備 其功能是用來補(bǔ)償電力系統(tǒng)中的無功功率,提高系統(tǒng)的功率因數(shù),例如并聯(lián)電容器等。 5.成套設(shè)備 它是按一次電路接線方案的要求,將有關(guān)一次設(shè)備及控制、指示、監(jiān)測(cè)和保護(hù)一次設(shè)備的二次設(shè)備組合為一體的電氣裝置,例如高壓開關(guān)柜、低壓配電屏、動(dòng)力和照明配電箱等。3.2.2一次設(shè)備的選擇
50、0;1.高壓一次設(shè)備的選擇 高壓開關(guān)柜有固定式和手車式兩大類,手車式(又稱移開式)高壓開關(guān)柜,雖具有檢修安全、供電可靠性高等優(yōu)點(diǎn),但價(jià)格較貴。在一般中小型工廠中,往往采用較為經(jīng)濟(jì)的固定式高壓開關(guān)柜。我國現(xiàn)在大量生產(chǎn)和廣泛應(yīng)用的是gg1a(f)型。這種防誤型開關(guān)柜裝設(shè)了防止電氣誤操作和保障人身安全的閉鎖裝置,即所謂“五防”功能防止誤跳、誤合斷路器,防止帶負(fù)荷拉、合隔離開關(guān),防止帶電掛接地線,防止帶接地線合隔離開關(guān),防止人員誤入帶電隔離。 本次設(shè)計(jì)中,確定用630kva的變壓器把10kv的高壓降到動(dòng)力設(shè)備所需要的電壓0.4kv。若有重要負(fù)荷,可靠性要求較高,則可選用手車式開關(guān)柜
51、,如jyn、kyn。本廠都是動(dòng)力設(shè)備,無重要負(fù)荷,因此,變電所可采用固定式開關(guān)柜。這里選用gg1a(f)03,此柜裝有g(shù)n1910型隔離開關(guān)1個(gè),隔離高壓電流,以保證其他電氣設(shè)備的安全檢修。sn1010/630500型少油斷路器1個(gè),可以通斷線路正常的負(fù)荷電流,也可以進(jìn)行短路保護(hù)。gg1a(f)03除備有以上兩種開關(guān)外,還有l(wèi)qj10型電流互感器2個(gè),分別接儀表和繼電器,以滿足測(cè)量和保護(hù)的不同要求。 容量500kva以上的變壓器,宜采用高壓計(jì)量。因此,對(duì)于630kva的變壓器,要求在變壓器的高壓側(cè)進(jìn)行計(jì)費(fèi),可選用與gg1a(f)型高壓開關(guān)柜配套使用、戶外安裝的pj1-a/j3型單電源
52、電纜進(jìn)出線的計(jì)量柜,正好滿足要求。柜內(nèi)裝有隔離開關(guān)、高壓斷路器及提供測(cè)量信號(hào)的電流互感器、電壓互感器。 考慮架空線路較之電纜線路發(fā)生故障時(shí)易于發(fā)現(xiàn)且易于檢查和修復(fù)。當(dāng)采用電纜線路時(shí),必須采用兩根電纜并列供電,每根電纜應(yīng)能承擔(dān)全部二級(jí)負(fù)荷。本設(shè)計(jì)中高壓開關(guān)柜的進(jìn)出線,采用經(jīng)一段電纜后接到架空線上。工廠變配電所高壓開關(guān)柜上面的高壓母線,通常采用lmy型硬鋁母線,對(duì)于主變壓器容量在1250kva及以下的變電所,高壓母線一般采用lmy40*4的規(guī)格。本配電所變壓器為630kva,因此可采用lmy3(40*4)的高壓母線。2. 低壓一次設(shè)備的選擇 低壓配電屏有固定式和抽屜式
53、兩種結(jié)構(gòu)型式。抽屜式價(jià)格昂貴,一般中小工廠多采用固定式。我國現(xiàn)在廣泛應(yīng)用的固定式低壓配電屏主要為pgl1和pgl2型。 根據(jù)前面所確定的車間配電系統(tǒng)及多路額定電流,本設(shè)計(jì)選用固定式低壓配電屏pgl2型,因?yàn)樵搹S為三級(jí)負(fù)荷,選用pgl2型即可滿足要求。 干線1、干線2、倉庫、裝配車間、戶外照明的干線,因?yàn)樗鼈兊娜酃茈娏鞣謩e為100a、200a、100a、200a、100a。因此可選用pgl236b,它具有100a的三路,200a的兩路。 干線7、干線10、冷作車間的干線,因?yàn)樗鼈兊娜酃茈娏鞣謩e為400a、200a、400a。因此可選用pgl234b,它具有400a的
54、兩路,200a的兩路,可以留一路200a的做備用,供以后增添設(shè)備時(shí)使用。 干線5、干線6、干線8、干線9,因?yàn)樗鼈兊娜酃茈娏鞣謩e為400a、400a、200a、200a。因此可選用pgl234b,它具有400a的兩路,200a的兩路。 干線3、干線4、干線11、室內(nèi)照明,因?yàn)樗鼈兊娜酃茈娏鞣謩e為100a、200a、100a、200a。因此可選用pgl236b,它具有100a的三路,200a的兩路。可以留一路100a的做備用,供以后增添設(shè)備時(shí)使用。選擇結(jié)果如表6.15所示。再加上4臺(tái)電容補(bǔ)償屏,低壓配電屏總共有9臺(tái)低壓配電屏。3.3低壓補(bǔ)償柜選擇 根據(jù)電容器在供電
55、系統(tǒng)中的裝設(shè)位置,有高壓集中補(bǔ)償、低壓集中補(bǔ)償和就地補(bǔ)償三種方式。其中,低壓集中補(bǔ)償能使車間變壓器的視在功率減小從而可使主變壓器容量選得較小,比較經(jīng)濟(jì),而且這種補(bǔ)償?shù)牡蛪弘娙萜鞴褚话憧砂惭b在低壓配電室內(nèi),運(yùn)行維護(hù)方便。 集中補(bǔ)償?shù)碾娙萜鹘M,有手動(dòng)投切和自動(dòng)調(diào)節(jié)兩種控制方式。對(duì)于自動(dòng)補(bǔ)償裝置來說,電路中的功率因數(shù)自動(dòng)補(bǔ)償控制器可按電力負(fù)荷的變化及功率因數(shù)的高低,以一定的時(shí)間間隔(10-15s),自動(dòng)控制各組電容器回路中基礎(chǔ)器的投切,使電網(wǎng)無功功率自動(dòng)得到補(bǔ)償,又不致過補(bǔ)償。 因此,本系統(tǒng)擬采用無功功率自動(dòng)補(bǔ)償屏,裝在變電低壓母線側(cè)集中補(bǔ)償。 選用總?cè)萘繛?60kva
56、。電容屏型號(hào)選:pgj1-2,pgj1-3三臺(tái)4防雷與接地設(shè)計(jì) 為防止雷電產(chǎn)生的過電壓波沿線路侵入變配電所而危及主變壓器等電氣設(shè)備的絕緣,本次設(shè)計(jì)在高壓開關(guān)柜中沒有裝設(shè)避雷器。在10kv架空進(jìn)線的最后一個(gè)電線桿中裝設(shè)一組hy5w4型避雷器。這種避雷器內(nèi)部無空腔,不存在內(nèi)外氣體互相滲漏問題,安裝運(yùn)輸無破損,可靠性很高。 凡是與架空線路相連的進(jìn)出線,在入戶處的電線桿進(jìn)行接地,可以達(dá)到重復(fù)接地的目的,每個(gè)電纜頭均要接地。 按規(guī)定10kv配電裝置的構(gòu)架,變壓器的380v側(cè)中性線及外殼,以及380v電氣設(shè)備的金屬外殼等都要接地,其工頻接地電阻要求re4。根據(jù)土壤電阻率=100m及
57、re<4,因此可采用6根直徑50mm的鋼管作接地,用40mm*4mm的扁鋼連接在距變電所墻腳2m處,打入一排=50mm、長(zhǎng)2.5m的鋼管接地體。每隔5m打入一根,管間用40mm*4mm的扁鋼連接。接地所用材 接地體材料表 名稱型號(hào)用量作用鋼管50mm2.5*6=15m作接地體扁鋼40mm*4mm5*5=25m連接鋼管5配電裝置配置 我國220/380v低壓配電系統(tǒng),廣泛采用中性點(diǎn)直接接地的運(yùn)行方式,而且引出有中性線(n)、保護(hù)線(pe)或保護(hù)中性線(pen)。 中性線(n線)的功能:一是用來接用額定電壓為系統(tǒng)相電壓的單相用電設(shè)備;二是用來傳導(dǎo)三相系統(tǒng)的不平衡電流;三
58、是減小負(fù)荷中性點(diǎn)的電位偏移。 保護(hù)線(pe線)的功能:它是用來保障人身安全、防止發(fā)生觸電事故用的接地線。系統(tǒng)中所有設(shè)備的外露可導(dǎo)電部分(指正常不帶電壓但故障情況下可帶電壓的易被觸及的導(dǎo)電部分,例如設(shè)備的金屬外殼、金屬構(gòu)架等)通過保護(hù)線接地,可在設(shè)備發(fā)生基地故障是減少觸電危險(xiǎn)。 保護(hù)中性線(pen線)的功能:它兼有中性線和保護(hù)線的功能。這種線在我國通常稱為“零線”,俗稱地線。 低壓配電系統(tǒng)接地型式,分為tn系統(tǒng)、tt系統(tǒng)和it系統(tǒng)。 1. tn系統(tǒng) tn系統(tǒng)的中性點(diǎn)直接接地,所有設(shè)備的外露可導(dǎo)電部分均接公共的保護(hù)線(pe)線或公共的保
59、護(hù)中性線(pen線)。這種公共pe線或pen線的方式,通稱為“接零”。tn系統(tǒng)又分為tn-c系統(tǒng)、tn-s系統(tǒng)和tn-c-s系統(tǒng)。 1) tn-c系統(tǒng)(圖5.1)圖5.1 tn-c 系統(tǒng) 其中的n線與pe線全部合為一根pen線。pen線中可有電流通過,因此對(duì)某些接pen線的設(shè)備將產(chǎn)生電磁干擾。如果pen線斷線,還可造成斷線點(diǎn)后邊的外露可導(dǎo)電部分帶電而造成人身觸電危險(xiǎn)。該系統(tǒng)由于pe線與n線合為一根pen線,因而節(jié)約了有色金屬和投資。較為經(jīng)濟(jì)。該系統(tǒng)在發(fā)生單相接地故障時(shí),線路的保護(hù)裝置應(yīng)該動(dòng)作,切除故障線路。tn-c系統(tǒng)過去在我國低壓配電系統(tǒng)中應(yīng)用最為普遍,但不適用
60、對(duì)人身安全和抗電磁干擾要求高的場(chǎng)所。2) tn-s系統(tǒng)(圖5.2) 其中的n線與pe線全部分開,設(shè)備的外露可導(dǎo)電部分均接pe線。由于pe線中無電流通過,因此設(shè)備之間不會(huì)產(chǎn)生電磁干擾。pe先斷線時(shí),正常情況下不會(huì)使斷線點(diǎn)后邊接pe線的設(shè)備外露可導(dǎo)電部分帶電;但在斷線點(diǎn)后邊有設(shè)備發(fā)生一相接殼故障是,將使斷線點(diǎn)后邊其他所有接pe線的設(shè)備外露可導(dǎo)電部分帶電,而造成人身觸電危險(xiǎn)。該系統(tǒng)在發(fā)生單相接地故障時(shí),線路的保護(hù)裝置應(yīng)該動(dòng)作,切除故障線路。該系統(tǒng)較之tn-c系統(tǒng)在有色金屬消耗量和投資方面有所增加。tn-s系統(tǒng)限制廣泛應(yīng)用于對(duì)安全要求較高的場(chǎng)所(如浴室和居民住宅等)及對(duì)電磁干擾要求較高的數(shù)據(jù)處理和精密檢測(cè)等試驗(yàn)場(chǎng)所,也越來越多地用于住宅供電系統(tǒng)。圖5.2 tn-s系統(tǒng)3) tn-c-s系統(tǒng)(圖5.3) 該系統(tǒng)的前一部分全部為tn-c系統(tǒng),而后邊有一部分為tn-c系統(tǒng),有一部分則為tn-s系統(tǒng),其中設(shè)備的外露可導(dǎo)電部分姐pen線或pe線。該系統(tǒng)綜合了tn-c系統(tǒng)和tn-
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 動(dòng)力柜施工合同范本
- 公用商業(yè)裝修合同范本
- 包裝供應(yīng)合同范本
- app合伙合同范本
- 以房換房合同范本
- 上傳網(wǎng)貸合同范本
- 包材委托加工合同范本文庫
- 2024年日照市某國有企業(yè)招聘考試真題
- 2024年青海海南州教育局招聘高中教師考試真題
- Module 2 public holidays unit 2英文版教學(xué)設(shè)計(jì) 2024-2025學(xué)年外研版英語九年級(jí)上冊(cè)
- 2024下半年上海事業(yè)單位招考易考易錯(cuò)模擬試題(共500題)試卷后附參考答案
- 網(wǎng)絡(luò)安全風(fēng)險(xiǎn)評(píng)估行業(yè)研究報(bào)告
- 新能源汽車充電設(shè)施安全檢查記錄表
- GB/T 38153.1-2024印刷技術(shù)測(cè)試印樣的實(shí)驗(yàn)室制備第1部分:漿狀油墨
- 2024高考物理考試大綱
- 《上市公司財(cái)務(wù)舞弊探究的國內(nèi)外文獻(xiàn)綜述》5000字
- 2024年護(hù)師類之護(hù)士資格證考試題庫
- 腰椎間盤突出癥課件(共100張課件)
- 委托調(diào)解民事糾紛協(xié)議書合同
- 林學(xué)概論完整版本
- GB/T 44458.3-2024運(yùn)動(dòng)用眼部和面部保護(hù)第3部分:水面游泳用眼鏡的要求和試驗(yàn)方法
評(píng)論
0/150
提交評(píng)論