




版權(quán)說(shuō)明:本文檔由用戶(hù)提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
ATSEngineeringInc.OWNER’SMANUALAH100DAttention1.Toavoidtheparticlesofimpurities(suchasiron,glass,othehomogenizertowearinletvalveandhomogenizingvalve,everymaterielshouldbefilteredbyfilterscreenof60-100mubeforeitisputintohomogenizertohomogenized.2.Itisforbiddentooperatemachinelongtimewhenthereisnomaterial3.Donotturnonhomogenizerunderhandlewastightly,forsuddenoverloadcapacitywilldamagemotor.4.AH08-100homogenizerisdesignedforproduction.Themachinecanworkforalongtime.5.Solidceramicplungerusedforhomogenizer.Sothetemperaturechangesofproductcontactpiecescouldn’tover70℃,ortheplungermayrupture.Therangeoftemperaturechangesshouldn’tover5℃,especiallyundercleaningoperation.1ThetheoryofHomogenization1.1WhatishomogenizationHomogenizationisfinishedbyhomogenizingvalveandpistonwhichcanrefinethematerialoccurredinthehomogeneousvalveandmixthem.1.2ThetheoryofhomogenizationMaterialisinhaledthroughthepiston.Withthehelpoftheplunger,itcanenterthegap.Also,thesizeofthegapischangingwithdifferentpressures.Releasingthepressure,thematerialejectwiththespeedofonethousandtoonethousandandfivehundredmeterspersecond.Threeeffectsproducedafterthematerialhittheimpactringwhichisoneofthevalvecomponents.HoleeffectThematerialaccumulatedhighenergyafterpressedbytheplunger.Whenpassingthelimitinggap,itcanreleasehighenergyafterthesuddendecreasingofpressure.Throughit,thematerialcanbesmashedandrefined.ThisiscalledHoleeffect.ImpacteffectWhenpassingthelimitinggap,thematerialsmashedandrefinedafterhittingthespecialimpactring.SheareffectThehighspeedingmaterialproducestrongshearingwhencrossingthevalvechamberchannelandlimitinggap.1.3Functiondiagramofplungerpump1.4Functiondiagramofhomogeneousvalve1.5Functiondiagramoftwostageshomogeneousvalves2Introductionofequipmentstructure2.1Pressureblock1-stainlessinletcup6-inletpipe2-inletvalveplunger7-outletpipe3-outletvalveplunger8-pressureblock4-pressuregauge9-thefirststagevalve5-thesecondstagevalve2.2ceramicplunger1-solidceramicplunger2-locknut3-tensionring4-spacerring-plungerseal2.3inletvalve1.fixednut2.fixedplug3.gasket4.o-ring5.spring6.ceramicball7.inletvalveseatPressureblockwasmadeoftwo-phasealloysstainlesssteel.Toensureequipmentworkwellunderhighpressureandeasilyremovalandinstallation.Theinternalpipesizeofpressureblockis12ml.Atleast50mlmaterialcanbeoperatedcircularlywiththespecialfeeder.Installationwithpressureblock:√Asolidceramicplunger,whichhassmoothsurfaceandhighcorrosion-resistantthatself-lubricating.√Specialmaterialofplungerseal.Itcanbeusedwithnowaterlubrication.√Unidirectionalinletvalveandoutletvalve.Avalvesupportwasbeinstalledunderinletvalvewhichcanberemoval.InletvalveismadeofalloyswithhighhardnessSTELLITE√Adigtalgaugeofhighprecisionwhichadoptedsanitarydesignandwithbattery.2.4homogeneousvalvegroup1-homogenousvalvebody2-O-ring3-InsideO-ring4-OutsideO-ring5-MandrilO-ring6-Mandril7-HandleAsetvalvewasinstalledinvalvebodybyrotatinghandletopushmandriltochangepressure.Theyformedastandardhomogenousvalvegroup.2.5homogeneousvalveWesuppliedtwosetsofhomogeneousvalvesforAH100D.Onesetemulsionvalveandonesetrupturevalve.Emulsionvalveisformedbyoneceramicball,onestainlesscollisionringandonetungstencarbidevalveseat.Bothsidesofvalveseatcanbeused,soitcanbeusedforamoretime.Emulsionvalveusuallyusedforpreparationofemulsion,forexample,Chemicalandpharmaceutical:vitaminemulsion,veinemulsionFoodandbeverage:essence,juice,vegetableproteinbeverageDairyproducts:milk,icecream,cream,yogurtRupturevalveisformedbyoneimpacthead,onevalveseatandoneimpactring.Theyaremadeoftungstencarbide.2.6TechnicalparametersoftheequipmentModel:AH100DCapacity:8-15L/HMaximumoperatingpressure:1800barStrokeofequipment:98-184times/minMaximumviscosity:2000CpMaximumtemperatureoftheproduct:90℃Maximumtemperatureofthesteam:121℃3.EquipmentOperation3.1.Checkbeforestart1.ATShigh-pressuredhomogenizerisdesignedtoreachveryhighpressure,therefore,goodoperationalhabitcanpreventandavoidinjuries&harmtodeviceitself.2.Inordertousethisequipmentaccuratelyandsafely,operatorsareaskedtomakeregularandnecessaryinspection,makesurethattheequipmentworksinidealconditionandpreventanypossibleproblems.Note:Makesurenometalparticlesinhomogenizingorbrokenmaterialfluid.3.MakesurethatboltsontheFlan,differentconnectingandpressuremassaretotallytightened.4.Putupthepowerlineandturnonthemainpower.5.Checktherotationaldirectionofmotor.Makesurethatfanrotatesinthedirectionofthearrow.Note:Ifthedirectionofmotorisnotconsistentwiththedirectionofthearrow,pleaseadjusttheconnectionontheelectricplug.6.Checkmanifoldsassemblecorrectornot,manifoldswasherswellornot,iftheyarecorrectandwell,thenyoucanreconfiguremanifolds.7.Makesurethattwostageshomogenizingvalvehandwheelsaretotallyloosened,butnottooloosen.8.Presstheswitchofpressuregaugeandconfirmthevalueiszero.9.Checkthering&pistonsealperiodicallytomakeitleak-off.3.2Turnontheequipment1.Addsomewaterintotheinletcup.2.Makesurehandleislooseandpressuregaugeshowsthereisnopressure.3.Rotatetheswitch,andthentheequipmentcanbegintowork.Accordingtotherequiredcapacitytoadjustconverterknobslowly,untilitreachaappropriatefrequencyandthedischargeiswell-distributedandcontinuous,withoutabnormalnoise.4.Whenthevalueofpressureiszero,youcanswitchofftheequipment.Note:Ifthere’snomaterialfluiddischargedfromtheoutletafteryouturnontheequipmentfor60seconds,itindicatesthatairblockingexistedinthepressuremass.Ifso,youshouldswitchofftheequipmentfirstly,turnonthechargingvalveanddivertmaterialfluidintopressuremass,thenturnonequipmentagain3.3PressureadjustmentFirst-stageadjustmentRotatehandleclockwisetoincreasepressure,androtatewiddershinstodecrease.Maxpressureis1800bar.Pressureincreased:1Adjustthepressureofsecond-stagevalve:rotatehandlewiddershinsandslowlytoincreasethepressuretorequirement.2Adjustthepressureoffirst-stage:rotatehandleclockwiseandslowlytoincreasethepressuretothetotalpressure.Remarks:itisanormalconditionthatthenoiseisincreasedbytheincreasedpressure.Pressuredischarged:1dischargepressureofthefirst-stagehomogeneousvalve:Rotatehandlewiddershinsandslowlytodecreasethepressuretothepressureofthesecond-stage,thenstoprotating.2Dischargepressureofthesecond-stagehomogeneousvalve:Rotatehandlewiddershinsandslowlyuntilthepressurewasdecreasedtozero,thenstoprotating.Attention:stoprotatinguntilthepressureiszero,donotrotatetooloose.3.4Operationalprocedure1.Putsomewaterintotheinletcup,turnonequipment.2.Adjustthepressuretotherequirement.3.Don’tputmaterialintotheinletcupuntilwaterflowedtothebottomofthecup.4.Attheprocessofhomogenous,operatorshouldpayattentiontothematerialintheinletcup.5.whenfinishedoperating,pleasedischargematerialinequipment.Putsomewaterintoinletcup.6.Adjustthepressuretozero,thencleanequipmentasyourrequirement.7.Rotateswitchwiddershins,turnoff.3.5Cleaning1.Putclearwaterintoinletcupimmediatelywhentheoperatingmaterialisflowinginthebottomofthecup.Thenuse60℃watertoclean.2.200barpressurecanbeusedwhencleaningtheequipment.3.Suiteddetergent:NaOH:Maximumconsistency3%Maxtemperature90℃HNO3:Maximumconsistency0.5%Maxtemperature70℃H3PO4:Maximumconsistency3%Maxtemperature85℃Hotwater:Maxtemperature95℃Steam:Maxtemperature130℃Attention:Detergentisprohibittoincludetheelementofchlorineandiodine.3.6SterilizationoperationAH100Dhomogenizerwasdesignedtosterilizebypuresteam.Themaximumtemperatureofthepuresteamis121℃.Thelongesttimeofsterilizationis30min.Thehighestpressureofsterilizationis3.8bar.1.Opentheinletclamp,removetheinletcup.2.Steamproducerandinletflangeisconnectedbyclamp.3.Timeofsterilizationshouldnotover30min.Donotturnonequipmentontheprocessofsterilization.4.Naturecoolingaftersterilization.Donotcoolingbycoolwater.5.Disconnecttheconnectionofinletflangeafterthepressureblockiscooltotally.4Maintained4.1TodisassembleandassemblevalvesofInlet/OutletTodisassemble1.Usespannertoremovethefixedbolt1&22.Useextractortoremovefixationdevice3&43.Usetweezerstoremovespringandceramicballof5&6Toassemble1.Putceramicball5onopeningofoutletvalvebytweezers,andputceramicball6oninletvalveseat.Makesuretheyareinmiddleposition.2.Tofixspringonfixationdevice3&4.Totightenfixedblot1&2byspanner.4.2TodisassembleandassemblethepressuregaugeTodisassembleLoosenboltsandremovethepressuregauge1.Donotpulltheheadofthegauge.Pleaseholdthebodyofthegauge.Toassemble1.Putgasket2belowpressuregauge,theninstallo-ring3.2.Putthegaugeintohole,thenfixbolts.4.3TodisassembleandassemblehomogeneousvalveTodisassembleandinspect1.Loosenboltofvalve,removethewholevalve.2.Pressvalveseatandrotatehandleclockwisetopushoutvalvegroupandmandril7.3.Checkthesurfaceofhomogeneousvalveseatandimpactheadorring.Toassemble1.LubricateallO-ringsbyfoodgradegreasebeforeassembleallproducts.2.Toputhandle8intovalve4byrotatingclockwise.3.Putimpactheadintovalve,thenputimpactring,atlastputvalveseatintovalve.4.Putwettinggasket2attachedtothesurfaceofvalveseat.5.Checkoutifthereisgasketintheholeofthefirst-stagevalve,thenputitintovalvebodyandfixthebolts.6.Toassemblethesecond-stagevalveisthesameprogressasthefirst-stage.4.4TodisassembleandassemblethepressureblockTodisassemble1.Removethefixedbolt1byspannerof24#2.Holdpressureblock2topullitoutgently,thenremovepressureblock.Theweightofpressureblockis20KG.3.Remove
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 19 大象的耳朵(教學(xué)設(shè)計(jì))-2023-2024學(xué)年統(tǒng)編版語(yǔ)文二年級(jí)下冊(cè)
- 第10課《古代的村落、集鎮(zhèn)和城市》教學(xué)設(shè)計(jì)-2023-2024學(xué)年高二歷史統(tǒng)編版(2019)選擇性必修2經(jīng)濟(jì)與社會(huì)生活
- 教科版信息技術(shù)高一必修 7.1信息資源管理教學(xué)設(shè)計(jì)
- 第18課《紫藤蘿瀑布》教學(xué)設(shè)計(jì) 2023-2024學(xué)年統(tǒng)編版語(yǔ)文七年級(jí)下冊(cè)
- 10-2 《師說(shuō)》教學(xué)設(shè)計(jì) 2024-2025學(xué)年統(tǒng)編版高中語(yǔ)文必修上冊(cè)
- 大眾健美操基本步伐方向的變化組合 教學(xué)設(shè)計(jì)-2023-2024學(xué)年高一上學(xué)期體育與健康人教版必修第一冊(cè)
- 第15課 貨幣的使用與世界貨幣體系的形成 教學(xué)設(shè)計(jì)-2024-2025學(xué)年高二上學(xué)期歷史統(tǒng)編版(2019)選擇性必修1國(guó)家制度與社會(huì)治理
- 2025至2031年中國(guó)甲硝咪唑行業(yè)投資前景及策略咨詢(xún)研究報(bào)告
- 2025至2031年中國(guó)激光石油割縫篩管行業(yè)投資前景及策略咨詢(xún)研究報(bào)告
- 2025至2031年中國(guó)母插頭行業(yè)投資前景及策略咨詢(xún)研究報(bào)告
- 2025年春節(jié)安全專(zhuān)題培訓(xùn)(附2024年10起重特大事故案例)
- 妊娠期用藥安全課件
- GB/T 44958-2024化工設(shè)備安全管理規(guī)范
- 《化妝品包裝材料相容性試驗(yàn)評(píng)估指南》
- 6張精美甘特圖圖表可編輯課件模板
- 2025年軋鋼原料工技能考試題庫(kù)
- 【政治】法律保障生活課件-+2024-2025學(xué)年統(tǒng)編版道德與法治七年級(jí)下冊(cè)
- 大學(xué)生考研規(guī)劃
- 四川政采評(píng)審專(zhuān)家入庫(kù)考試基礎(chǔ)題復(fù)習(xí)試題
- 智研咨詢(xún)-2025年中國(guó)生鮮農(nóng)產(chǎn)品行業(yè)市場(chǎng)全景調(diào)查、投資策略研究報(bào)告
- 車(chē)輛采購(gòu)論證方案
評(píng)論
0/150
提交評(píng)論