供熱工程課程設(shè)計(jì)計(jì)算書-1-供熱工程課程設(shè)計(jì)設(shè)計(jì)題目:天津某辦公樓供熱系統(tǒng)設(shè)計(jì)班級(jí): 建筑節(jié)能 姓名:_學(xué)號(hào): 指導(dǎo)老師: 日期:供熱工程課程設(shè)計(jì)計(jì)算書-2-目錄TOC\o"1-5"\h\z.工程概況及設(shè)計(jì)依據(jù) 3工程概況 3設(shè)計(jì)計(jì)算參數(shù) 3.供熱熱負(fù)荷計(jì)算 4圍護(hù)結(jié)構(gòu)基本耗熱量計(jì)算 4圍護(hù)結(jié)構(gòu)附加耗熱量 4門窗縫隙滲入冷空氣的耗熱量 5以一層101會(huì)議室進(jìn)行舉例計(jì)算 6其他房間熱負(fù)荷計(jì)算 9.采暖系統(tǒng)的選擇及管道布置 16熱水供暖系統(tǒng)分類 16機(jī)械循環(huán)系統(tǒng)與重力循環(huán)系統(tǒng)的主要區(qū)別 16選擇及布置 16膨脹水箱的計(jì)算 17.散熱器的選擇及安裝 17散熱器的選擇 17散熱器的安裝 17散熱器的計(jì)算 17.系統(tǒng)水力計(jì)算 20水力計(jì)算方法 20水力計(jì)算舉例 20其他管路水力計(jì)算 21水力平衡校核 26.個(gè)人總結(jié) 31參考文獻(xiàn)附錄施工圖供熱工程課程設(shè)計(jì)計(jì)算書-3-一、工程概況及設(shè)計(jì)依據(jù)工程概況該項(xiàng)目是位于天津市(屬于寒冷地區(qū))的一座三層辦公樓,包括會(huì)議室、辦公室、值班室、閱覽室、廁所等功能房間。一層建筑層高4.2m,二三層層高3.3m。設(shè)計(jì)計(jì)算參數(shù)氣象資料:冬季采暖室內(nèi)計(jì)算溫度辦公室為20℃,會(huì)議室18℃,走廊、樓梯間、衛(wèi)生間為16℃冬季室外計(jì)算溫度-9℃冬季室外平均風(fēng)速6.0m/s圍護(hù)結(jié)構(gòu):1)外墻:保溫外墻(37墻),傳熱系數(shù)為K=0.60W/(m2-K)2)內(nèi)墻:兩面抹灰一磚墻(37墻),傳熱系數(shù)為K=1.53W/(m2?K);一樓衛(wèi)生間隔墻:兩面抹灰一磚墻(24墻),傳熱系數(shù)為K=2.03W/(m2?K);3)外窗:雙層鋁合金推拉窗,傳熱系數(shù)為K=3.0W/(m2-K)4)門:?jiǎn)螌幽鹃T;K=4.65W/(m21K)5)屋頂:保溫屋頂,傳熱系數(shù)K=0.55W/(m2-K);6)地面為不保溫地面,K值按地帶決定。其中第一地帶傳熱系數(shù)K1=0.465W/(m2-K);第二地帶傳熱系數(shù)K2=0.233W/(m2-K);第三地帶傳熱系數(shù)K3=0.116W/(m2-K);第四地帶傳熱系數(shù)K4=0.07W/(m2-K);熱源:室外供熱管網(wǎng),采用機(jī)械循環(huán)上供下回的方式供水,供水溫度95℃,回水溫度70℃,引入管處供水壓力滿足室內(nèi)供暖要求。供熱工程課程設(shè)計(jì)計(jì)算書-4-二、供熱熱負(fù)荷計(jì)算《規(guī)范》中所規(guī)定的“圍護(hù)結(jié)構(gòu)的耗熱量”實(shí)質(zhì)上是圍護(hù)結(jié)構(gòu)的溫差傳熱量、加熱由于外門短時(shí)間開啟而侵入的冷空氣的耗熱量以及一部分太陽(yáng)輻射熱量的代數(shù)和。為了簡(jiǎn)化計(jì)算,《規(guī)范》規(guī)定,圍護(hù)結(jié)構(gòu)的耗熱量包括基本耗熱量和附加耗熱量?jī)刹糠帧?.1圍護(hù)結(jié)構(gòu)的基本耗熱量計(jì)算公式如下:Q=KA(tR-to,w)aQ——圍護(hù)結(jié)構(gòu)的基本耗熱量,W;K——圍護(hù)結(jié)構(gòu)的傳熱系數(shù),W/(m2-K);A——圍護(hù)結(jié)構(gòu)的面積,m2;tR——冬季室內(nèi)計(jì)算溫度,?!鎡o,w——供暖室外計(jì)算溫度,。C;a一圍護(hù)結(jié)構(gòu)的溫差修正系數(shù)。整個(gè)建筑的基本耗熱量等于它的圍護(hù)結(jié)構(gòu)各部分基本耗熱量的總和,算出基本耗熱量后再進(jìn)行朝向和高度修正(因風(fēng)速較小,風(fēng)力修正忽略不計(jì)),圍護(hù)結(jié)構(gòu)附加耗熱量朝向修正率不同朝向的圍護(hù)結(jié)構(gòu),收到的太陽(yáng)輻射是不同的;同時(shí),不同的朝向,風(fēng)的速度和頻率也不同。因此,《規(guī)范》規(guī)定對(duì)不同的垂直外圍護(hù)結(jié)構(gòu)進(jìn)行修正,其修正率為:北、東北、西北朝向: 0—10%東、西朝向: -5%東南、西南朝向: -10%——15%南向 -15%——30%選用修正率時(shí)應(yīng)考慮當(dāng)?shù)囟救照章始拜椛鋸?qiáng)度的大小。冬季日照率小于35%的地區(qū),東南、西南和南向的修正率宜采用-10%-0%,其他朝向可不修正。風(fēng)力附加率在《規(guī)范》中明確規(guī)定:在不避風(fēng)的高地、河邊、海岸、曠野上的建筑物以及城鎮(zhèn)、廠區(qū)內(nèi)特別高的建筑物,垂直外圍護(hù)結(jié)構(gòu)熱負(fù)荷附加5%-10%。該辦公
供熱工程課程設(shè)計(jì)計(jì)算書-5-樓不計(jì)算風(fēng)力附加。外門附加率為加熱開啟外門時(shí)侵入的冷空氣,對(duì)于短時(shí)間開啟無(wú)熱風(fēng)幕的外門,可以用外門的基本耗熱量乘上按下表查出的相應(yīng)的附加率。陽(yáng)臺(tái)門不應(yīng)考慮外門附加率。外門附加率(%)建筑物性質(zhì)附加率公共建筑或生產(chǎn)廠房的主要出入口500民用建筑或工廠的輔助建筑物,當(dāng)其樓層為n時(shí)有兩個(gè)門斗的三層外門60n有門斗的雙層外門80n無(wú)門斗的單層外門65n2.2.4高度附加率由于室內(nèi)溫度梯度的影響,往往使房間上部的傳熱量增大。因此規(guī)定:當(dāng)民用建筑和工業(yè)企業(yè)輔助建筑的房間凈高超過(guò)4m時(shí),每增加1m,附加率為2%,但最大附加率不得超過(guò)15%,該辦公樓房間凈高均不超過(guò)4m,高度附加0%。門窗縫隙滲入冷空氣的耗熱量由于縫隙寬度不一,風(fēng)向、風(fēng)速和頻率不一,因此由門窗縫隙滲入的冷空氣量很難準(zhǔn)確計(jì)算。規(guī)范推薦,對(duì)于多層和高層民用建筑,可按下式計(jì)算門窗縫隙滲入冷空氣的耗熱量:Qi=0.278LpaoCp(tR-to.h)Qi——為加熱門窗縫隙滲入的冷空氣耗熱量,W;L——滲透冷空氣量,m3/h,可按《規(guī)范》附錄D中給出的公式計(jì)算,對(duì)多層建筑可按換氣次數(shù)(下表)計(jì)算;PaoCp--采暖室外計(jì)算溫度下的空氣密度,kg/m3;空氣定壓比熱,PaoCp-to.h——采暖室外計(jì)算溫度,?!?。換氣次數(shù)房間類型一面有外窗或外門房間兩面有外窗或外門的房間三面有外窗的房間門廳換氣次數(shù)(h-1)1/4-2/30.5-11.0-1.52.0為計(jì)算簡(jiǎn)便,該辦公樓各房間的冷風(fēng)滲入耗熱量均采用換氣次數(shù)為0.5時(shí)進(jìn)行計(jì)算。
供熱工程課程設(shè)計(jì)計(jì)算書-6-2.4下面以一層101會(huì)議室進(jìn)行舉例計(jì)算北外墻耗熱量計(jì)算:公式:Q=KA(tR-to,w)aK值的確定,K=1/R=1.24,傳熱系數(shù)取1.24W/(m2?K)。2)北外墻面積A=3.795X3.2-1.2X2.6=9.024m23)溫差修正系數(shù)a=0.74)冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃5)故北外墻基本耗熱量為:Q=1.24X9.024X27.8X0.7=217.75W6)北向朝向修正取5%,風(fēng)力修正0%,高度附加0%,所以北外墻的耗熱量就是: Q’=217.75X(1+5%)=228.64W北外門耗熱量計(jì)算:公式:Q=KA(tR-to,w)aK值的確定,根據(jù)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》規(guī)定,外門傳熱系數(shù)取4.65W/(m2,K)o是:北外門面積A=1.2X2.6=3.12m2是:溫差修正系數(shù)a=0.7冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃故北外門基本耗熱量為:Q=4.65X3.12X27.8X0.7=282.33W北向朝向修正取5%,風(fēng)力修正0%,高度附加0%,所以南外門的耗熱量就Q’=282.33X(1+5%)=296.45W西外墻耗熱量計(jì)算:公式:Q=KA(tR-to,w)aK值的確定,根據(jù)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》規(guī)定,K=1/R=1.24,傳熱系數(shù)取1.24W/(m2-K)o2)西外墻面積A=7.095X3.2=22.704m23)溫差修正系數(shù)a=1.04)冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃5)故西外墻基本耗熱量為:Q=1.24X22.704X27.8X1.0=782.65W6)西向朝向修正取-5%,風(fēng)力修正0%,高度附加0%,所以北外墻的耗熱量就是: Q’=782.65X(1-5%)=743.52W南外墻耗熱量計(jì)算:公式:Q=KA(tR-to,w)aK值的確定,根據(jù)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》規(guī)定,K=1/R=1.24,傳熱系數(shù)取1.24W/(m2-K)o2)南外墻面積A=3.795X3.2-1.5X2.3=8.694m23)溫差修正系數(shù)a=1.04)冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃供熱工程課程設(shè)計(jì)計(jì)算書-7-5)故南外墻基本耗熱量為:0=1.24X8.694X27.8X1.0=299.70W6)南向朝向修正取-15%,風(fēng)力修正0%,高度附加0%,所以北外墻的耗熱量就是: Q’=299.70X(1-15%)=254.745W南外窗耗熱量計(jì)算:公式:Q=KA(tR-to,w)aK值的確定,根據(jù)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》規(guī)定,外窗傳熱系數(shù)取6.40W/(m2,K)o2)南外窗面積A=1.5X2.3=3.45m23)溫差修正系數(shù)a=1.04)冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃5)故北外窗基本耗熱量為:Q=6.4.X3.45X27.8X1.0=613.824W6)南向朝向修正取-15%,風(fēng)力修正0%,高度附加0%,所以北外墻的耗熱量就是: Q’=613.824X(1-15%)=521.75W保溫地面耗熱量計(jì)算:保溫地面分為四種類型,各類型寬度為2m,外墻墻角處面積需要計(jì)算兩次。各類型地面?zhèn)鳠嵯禂?shù)如下表所示:地面類型I型地面II型地面?zhèn)鳠嵯禂?shù)(W/(m21K))0.4050.2161)1型地面耗熱量計(jì)算:①傳熱系數(shù)為0.405W/(m2-K)②地面面積A=3.06X6.36-2.36X1.06+2X2X2=24.96m2③溫差修正系數(shù)a=1.0④冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃故I型地面耗熱量為:Q1=0.405X24.96X27.8X1.0=281.025W2)11型地面耗熱量計(jì)算:①傳熱系數(shù)為0.216(W/(m2-K)②地面面積A=2.36X1.06=2.5016m2③溫差修正系數(shù)a=1.0④冬季室內(nèi)采暖設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃故II型地面耗熱量為:Q2=0.216X2.5016X27.8X1.0=15.022W供熱工程課程設(shè)計(jì)計(jì)算書-8-4)地面耗熱量合計(jì):Q=Q1+Q2=296.047W門窗縫隙滲入冷空氣的耗熱量計(jì)算:1)計(jì)算公式為Q2=0.278LVpaocpCtR-to.)2)滲入冷空氣量按換氣次數(shù)0.5h1計(jì)算,朝向修正系數(shù)南(0.4)北(1)門,窗縫隙滲入總空氣量為(0.35X7.6X1)+(0.35X9.2X0.4)=3.948m33)空氣密度取1.2kg/m34)定壓比熱取1.0kJ/(kg.℃)5)室內(nèi)設(shè)計(jì)溫度18℃,室外設(shè)計(jì)溫度-9.8℃故門窗門窗縫隙滲入冷空氣的耗熱量為:Q2=0.278X1.2X3.948X1.0X27.8=36.6W外門冷風(fēng)侵入耗熱量計(jì)算:可按開啟時(shí)間不長(zhǎng)的一道門考慮1)計(jì)算公式為Q3=NQ(門)=0.65X296.45=192.692.4.9一層101會(huì)議室耗熱量匯總?cè)缦卤硭?分項(xiàng)名稱北外墻北外門西外墻南外墻南外窗地面滲入耗熱量侵入耗熱量耗熱量(W)228.64296.45782.65254.745613.824296.04736.6192.69總計(jì)(W)2671.64故一層101會(huì)議室總熱負(fù)荷為2671.64W。三、散熱器的選擇散熱器的選擇室內(nèi)供暖系統(tǒng)的末端散熱裝置是供暖系統(tǒng)完成供暖任務(wù)的重要組成部分。它向室內(nèi)散熱以補(bǔ)充房間的熱損失,從而保持室內(nèi)要求的溫度。綜合各個(gè)方面因素考慮,本辦公樓采暖散熱器采用TZ2-5-5(M-132型)鑄鐵散熱器。該散熱器的各項(xiàng)參數(shù)如下表所示:型號(hào)散熱面積(m2/片)水容量(1/片)重量(kg/片)工作壓力(Mpa)傳熱系數(shù)計(jì)算公式(W/(m2-K)TZ2-5-5(M-132型)0.241.3270.5K=2.426A10.286M-132型散熱器為柱型二柱散熱器,其寬度為132mm,兩邊為柱狀H1=500mm,H=584mm,L=80mm,中間為波浪形的縱向肋片。供熱工程課程設(shè)計(jì)計(jì)算書-9-散熱器的安裝散熱器布置在外墻窗臺(tái)下,這樣能迅速加熱室外滲入的冷空氣,阻擋沿外墻下降的冷氣流,改善外窗、外墻對(duì)人體冷輻射的影響,使室溫均勻。為防止散熱器凍裂,兩道外門之間,門斗及開啟頻繁的外門附近不宜設(shè)置散熱器。該辦公樓散熱器均采用明裝的形式,上部加蓋板且蓋板距離散熱器上部100mm。單個(gè)散熱器的連接形式采用同側(cè)上進(jìn)下出。散熱器的計(jì)算散熱器面積計(jì)算公式為:(m2)F=(m2)K(t-1)123pjnQ——散熱器的散熱量,W;tpj——散熱器內(nèi)熱媒平均溫度,?!?;tn——供暖室內(nèi)計(jì)算溫度,。C;K——散熱器的傳熱系數(shù),W/(m2-K);B1——散熱器組裝片數(shù)修正系數(shù);B2——散熱器連接形式修正系數(shù);B3——散熱器安裝形式修正系數(shù)。其中tpj=(tsg+tsh)/2℃tsg——散熱器進(jìn)水溫度,。℃;tsh——散熱器出水溫度,。℃。對(duì)于雙管熱水供暖系統(tǒng),散熱器的進(jìn)、出口溫度分別按系統(tǒng)的設(shè)計(jì)供、回水溫度計(jì)。當(dāng)計(jì)算出散熱器的面積之后,即可計(jì)算每個(gè)散熱器的散熱片數(shù),計(jì)算公式為:n=F/ff——每片或每1m長(zhǎng)的散熱器散熱面積,m2/片或m2/m。而該辦公樓選取的M-132型散熱器每個(gè)散熱器的片數(shù)不能超過(guò)20片,在初步選定散熱片數(shù)之后,要對(duì)散熱器組裝片數(shù)修正系數(shù)B1進(jìn)行修正,B1的選取如下表所示:每組片數(shù)<66~1011?20>20010.951.001.051.10以101辦公室為例進(jìn)行散熱器計(jì)算,該辦公室的熱負(fù)荷為2671.64W。1)首先已知條件:Q=2671.64W,tsg=95℃,tsh=50℃,B1首先取1.0,由于該散熱器采用同側(cè)上進(jìn)下出,查表知02=1.0,同時(shí)蓋板距散熱器100mm,B3=1.02;2)由公式K=2.426At0.286=7.96W/(m2-K);tpj=(tsg+tsh)/2=(95+70)/2=82.5℃;4)At=tpj-tn=82.5-18=64.5℃5)由F=—Q—ppp=5.3m2;K(t-1)123pjn供熱工程課程設(shè)計(jì)計(jì)算書-10-6)分成兩個(gè)散熱器所以F=F1/2=2.657)得到散熱器片數(shù)n=F/f=2.65/0.24=11.0,取整n=12片;8)01修正,當(dāng)n=11時(shí),01=1.05,帶回4)再次進(jìn)行計(jì)算F‘=2.78m2,推出n'=11.61,實(shí)際片數(shù)仍取12片。五、系統(tǒng)水力計(jì)算水力計(jì)算方法1)首先對(duì)供暖系統(tǒng)各個(gè)管段進(jìn)行分段編號(hào),并選擇最不利環(huán)路,方便計(jì)算;2)其次明確各個(gè)管段所承擔(dān)的熱負(fù)荷;3)確定了熱負(fù)荷之后根據(jù)公式G=—Q—Cp(tgth)G——水流量,Kg/h;Q——熱負(fù)荷,W;Cp——比熱,4.2kJ/(kg.℃);tg——設(shè)計(jì)供水溫度,。c;th——設(shè)計(jì)回水溫度,℃。4)求出各個(gè)管段的流量之后,采用平均比摩阻法確定相應(yīng)參數(shù),一般選取60?120Pa/m。本次設(shè)計(jì)供回水溫度分別為75℃和50℃,相應(yīng)數(shù)據(jù)無(wú)法查取,現(xiàn)采用供回水溫度為95℃和70℃的數(shù)據(jù)(《供暖通風(fēng)設(shè)計(jì)手冊(cè)》)查??;5)在《供熱通風(fēng)設(shè)計(jì)手冊(cè)》上可以查到公稱管徑、比摩阻、水流速等數(shù)據(jù);6)確定相應(yīng)的管長(zhǎng)和該管的動(dòng)壓,即可根據(jù)以下公式計(jì)算管道壓力損失:△P=APy+APj=Rl+APj△P——計(jì)算管段的壓力損失,Pa;△Py——計(jì)算管段的沿程損失,Pa;△Pj——計(jì)算管段的局部損失,Pa;R——每米管長(zhǎng)的沿程損失,Pa/m;l——管段長(zhǎng)度,m。7)水力平衡校核。該辦公樓采用雙管異程系統(tǒng),一般選擇最遠(yuǎn)端和最近端的兩個(gè)立管進(jìn)行水力平衡的計(jì)算,相差較大的可選擇相鄰的立管計(jì)算。水力計(jì)算舉例該辦公樓分為南北兩個(gè)環(huán)路,故需要對(duì)兩個(gè)環(huán)路分別進(jìn)行水力平衡的校核,首先需要計(jì)算出每個(gè)管段的管徑,包括回水管和供水管?,F(xiàn)選擇北向環(huán)路立管I1-2管段進(jìn)行舉例計(jì)算,計(jì)算簡(jiǎn)圖如下圖所示:
供熱工程課程設(shè)計(jì)計(jì)算書-11-北向立管11-2管段水力計(jì)算過(guò)程:1)由簡(jiǎn)圖可知,其熱負(fù)荷包括三層樓梯、二層樓梯、一層樓梯和一層門廳的熱負(fù)荷,Q二4398.34W;2)根據(jù)公式G二 Q , G=4398.34X3.6/4.2/25=151.30kg/h;Cp(tgth)3)得出流量G之后,查《供暖通風(fēng)設(shè)計(jì)手冊(cè)》可得公稱管徑為15mm,比摩阻為69.82pa/m,流速為0.22m/s;4)計(jì)算沿程阻力。由圖可知北向立管11-2管段管長(zhǎng)為3.3m,沿程阻力APy二69.82X3.3=230.41pa;5)計(jì)算沿程阻力。由圖可知北向立管11-2管段包括一個(gè)2個(gè)閘閥(Z=1.5),一個(gè)散熱器(Z=2),一個(gè)分流三通(Z=3),一個(gè)90°彎頭(Z=2)。再由查得的流速v=0.22m/s,由公式0.5pv2計(jì)算出動(dòng)壓為24.2pa,故局部阻力就為:APj=(1.5X2+2+3+2)X24.2=242pa6)立管11-2管段總阻力為:APy+APj=230.41+242=472.41pa。其他環(huán)路的計(jì)算列表如下,首先南向的計(jì)算簡(jiǎn)圖如下所示:供熱工程課程設(shè)計(jì)計(jì)算書-12-其他環(huán)路的水力計(jì)算表格:1)供水主立管及其他供水立管立管1怏水管水力計(jì)算管段號(hào)熱負(fù)荷Q(W)水流量G(kg/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力北向立管I1-2439S.34151.303.3150.2269.8224.2230.4:062-33513.4120.063.3150.174:5.9314.45151.5693~42S66.9S9S.62L2150.1532.7211.25137.424北向立管n1-23516.43120.973.3150.174:5.9314.45151.5692-319SS.S56S.423.3100.27211.8836.45699.2043-41545.9653.104.2100.21127.6522.05536.13北向立管山1-2617S.91212.553.3150.3132.23454:36.3592-33916.95134.743.3150.257.2720100.9913~42261.9277.81L2150.1120.76.0586.94北向立管w1-26619.26227.703.3150.33157.3554.45519.2552-34151.92142.S33.3150.261.3220202.3563-42261.9277.015.4:150.1120.76.05111.70南向立管I1-27115.56244.783.3200.239.520130.352-34073.76167.663.3150.24S3.620.8275.003~430S6.74106.IS5.4150.1535.8211.25193.4:28南向立管n1-25779.0190.033.3150.29120.4842.05397.5042-33745.2412S.S43.3150.1953.351S.05176.0553-42261.9277.014.2150.1120.76.0506.94南向立管山1-26565.3225.S53.3150.32144.5251.24:76.9162-34007.00137.043.3150.257.2720100.9913~42261.9277.81L2150.1120.76.0586.94南向立管w1-21693.3958.253.3100.23156.7926.45517.4:072-376826.423.3100.135.4:55116.985主立管40S63.551405.7110.8320.3977.8276.0584:0.4=56
供熱工程課程設(shè)計(jì)計(jì)算書-13-2)回水立管計(jì)算立管回水管水力計(jì)算管段號(hào)熱負(fù)荷水流量G(ks/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力北向立管I2-3085.330.453.3100.1246.017.2151.8333-41531.3652.603.3150.OS10.623.235.0464-54398.34151.304.2150.2269.0224.2293.244北向立管n2-31527.5052.553.3150.0010.623.235.0463-41970.4767.703.3150.116.11553.1634-53516.43120.974.2150.1745.93U.45192.906北向立管山2-32261.9677.S13.3150.1120.76.056S.313-43240.74111.483.3150.1639.05612.8128.88484-5617S.91212.553.3200.172S.49U.4594.017北向立管w2-32467.34S4.8S3.3150.1224.767.281.70S3-44357.34149.093.3150.2269.0224.2230.4064-56619.26227.703.3200.IS33.7716.2111.441南向立管I2-32241.377.123.3150.1120.76.0568.313-4402S.S2133.593.3150.261.3220202.3564-57115.56244.783.3200.239.520130.35南向立管n2-32034.5669.993.3150.116.99556.0673-43517.88121.023.3150.1745.9314.45151.5694-55779.8190.S33.3200.1626.0112.885.033南向立管山2-32558.2208.003.3150.1325.038.4585.2393-44:303.33140.043.3150.2269.8224.2230.4064-56565.3225.S53.3200.IS33.7716.2111.441南向立管w2-3925.3931.S33.3100.1351.798.45170.9073-41693.395S.253.3150.OS12.OS3.239.064供熱工程課程設(shè)計(jì)計(jì)算書-14-3)水平干管供水管水力計(jì)算水平干管供水管水力計(jì)算管段號(hào)熱負(fù)荷Q(W)水流量G(kg/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力北向0-I195S1.98673.622.57250.M477.3757.8198.S409I-II151S3.64522.3210250.2646.3633.8463.6II-III11667.21401.356.6200.3296.3751.2636.042III-IV6619.26227.700.4:200.1033.7716.22S3.660南向0-I21154.05727.703.9250.3636.34:64.0768.426I-II14033.4:9402.923.4250.2439.0323.0334.572II-IIIS25S.692S4.107.2200.224S.9124.2352.152III-IV1693.3958.258.4150.0812.083.2101.4724)水平干管回水管水力計(jì)算水平干管回水管水力計(jì)算管段號(hào)熱負(fù)荷Q⑺水流蚩G(kg/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力北向IV5-III56619.26227.708.4200.1833.7716.2283.668III5-II511667.21401.356.6200.3296.3751.2636.042II5-I515103.64522.3210250.2646.3633.S463.6I5-619581.98673.622.57250.3477.3757.8198.8409由3」IV5-III51693.3950.250.4150.0812.083.2101.472III5-II50250.69284.107.2200.2248.9124.2352.152II5-I514030.49482.928.4250.2439.832S.8334.572I5-621154.05727.700.9250.3686.3464.S760.426主回水管6-740863.5514:05.7110.8320.3977.8276.05840.456
供熱工程課程設(shè)計(jì)計(jì)算書-15-5)水平支管水力計(jì)算(供回水管徑相同)水平支管水力計(jì)算,供回水管管徑相同管段號(hào)熱負(fù)荷Q(W)水流量G(kg/h)管長(zhǎng)L(UI)管徑'流速比摩阻動(dòng)壓沿程阻力北向立管I三層樓梯間805.330.450.5100.1246.017.223.005二層樓梯間646.0622.220.5100.0914.634.057.315一層樓梯間1323.6145.530.5100.1S93.3716.246.605門廳(1)1543.3753.090.5100.21127.6522.0563.025北向立管n三層衛(wèi)生間603.7720.770.6100.0813.33.27.9S306923.8131.701.4100.1351.79S.4572.506二層衛(wèi)生間442.8915.240.6100.069.981.85.90S一層衛(wèi)生間490.4616.370.6100.069.981.35.9301021055.536.310.8100.1464.349.S51.472北向立管m305(1)1130.9S38.911.4100.1571.1111.2599.554:305(2)1130.9838.911.4100.1571.1111.2599.554:20S978.7833.671.4100.1457.99.8S1.06207676.2523.261.4100.115.96522.344:101(1)1130.9630.911.4100.1571.1111.2599.554101⑵1130.9630.911.4100.1571.1111.2599.554北向立管w304(1)1233.6742.441.4100.1785.6214.45119.368304(2)1233.6742.441.4100.1785.6214.45119.368206(1)94532.511.4100.1351.798.4572.506206(2)94532.511.4100.1351.798.4572.506101(3)1130.9630.911.4100.1571.1111.2599.554101(4)1130.9630.911.4100.1571.1111.2599.554南向立管I301⑴1120.938.562.5100.1571.1111.25177.775301(2)1120.938.562.5100.1571.1111.25177.775201(1)893.5130.742.5100.1246.017.2115.025201(2)893.5130.742.5100.1246.017.2115.025門廳(2)1543.3753.090.8150.0810.623.2S.496門廳(3)1543.3753.093.5150.0S10.623.237.17南向幺管n302(1)1017.2334.991.4100.1457.99.301.06302(2)1017.2334.991.4100.1457.99.301.06202741.6625.511.4100.135.4:5549.63203741.6625.511.4100.135.4:5549.63101⑸1130.963S.911.4100.1571.1111.2599.554:101(6)1130.9630.911.4100.1571.1111.2599.554南向立管m303(1)1279.1144.001.4100.IS93.3716.2130.718303(2)1279.1144.001.4100.IS93.3716.2130.718204741.6625.511.4100.135.45549.632051003.534.521.4100.1457.99.S81.06101(7)1130.9638.911.4100.1571.1111.2599.554:101(8)1130.9638.911.4100.1571.1111.2599.554:南向立管w三層走廊925.3931.S30.5100.1351.79S.4525.095二層走廊76826.420.5100.135.4:5517.725供熱工程課程設(shè)計(jì)計(jì)算書-16-水力平衡校核水力平衡計(jì)算管段的選擇該辦公樓分南北兩向,南北向水力平衡需要分別計(jì)算。北向選擇北向立管”
和立管川進(jìn)行水力平衡計(jì)算,而南向則選擇南向I和南向III進(jìn)行水力平衡計(jì)算。北向環(huán)路水力平衡計(jì)算1)計(jì)算簡(jiǎn)圖如下所示:2)對(duì)立管111和立管”的全部阻力進(jìn)行計(jì)算,計(jì)算過(guò)程如5.2所示,現(xiàn)僅列表格如下所示:
供熱工程課程設(shè)計(jì)計(jì)算書-17-L北向水力平衡計(jì)算選取立管田和立管IV進(jìn)行平衡計(jì)算(1)水平支管沿程阻力,包括供水和回水,所得結(jié)果乂2管段號(hào)熱負(fù)荷Q(W)水流量G(kg/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力總沿程阻力北向立管m305(1)1130.9030.911.4100.1571.1111.2599.554501.62305(2)1130.9S3S.911.4100.1571.1111.2599.554208978.7033.671.4100.1457.99.881.06207676.2523.261.4100.115.96522.344101(1)1130.9630.911.4100.1571.1111.2599.554101(2)1130.9630.911.4100.1571.1111.2599.554北向立管IV304(1)1233.6742.441.4100.17B5.6214.45119.0685B3.056304(2)1233.6742.441.4100.1785.6214.45119.S68206(1)94532.511.4100.1351.798.4572.506206(2)94532.511.4100.1351.798.4572.506101(3)1130.9630.911.4100.1571.1111.2599.554101(4)1130.9630.911.4100.1571.1111.2599.554(2)供水立管沿程阻力熱負(fù)荷Q(W)水流量G(kg/h)管長(zhǎng)L(m)公稱管徑流速比摩阻動(dòng)壓沿程阻力總計(jì)北向立管皿1-26178.91212.553.3150.3132.2345436.359712.292-33916.95134.743.3150.257.27201S8.9913-42261.9277.014.2150.1120.76.0506.94總計(jì)北向立管W1-26619.26227.703.3200.1B33.7716.2111.441400.7372-34151.92142.B33.3150.261.3220202.3563-42261.9277.014.2150.1120.76.0506.94(3)回水立管沿程阻管段號(hào)熱負(fù)荷水流量G(ks/h)管長(zhǎng)L(m)管役流速比摩阻動(dòng)壓沿程阻力總計(jì)北向立管皿22261.9277.013.3150.1120.76.0568.3130B.04433916.95134.744.2150.257.2720240.534北向立管w總計(jì)22467.34B4.003.3150.1223.717.270.243455.27134357.34149.B95.4150.2269.B224.2377.02S供熱工程課程設(shè)計(jì)計(jì)算書-18-(4)供水立管局都阻力局部阻力系數(shù)合流三通分流三通四通90°彎頭散熱器閘閥突然擴(kuò)大突然縮小333221.510.5分項(xiàng)局部阻力管段合流三通分流三通四通90。彎頭散熱器閘閥突然擴(kuò)大突然縮小動(dòng)壓局部阻力總計(jì)北向立管m1-20013501B0202.504545562.52-300600S06002020220S49.053-4018.150024.210.1506.056.0566.55總計(jì)北向立管IV1-200.0040.6064.872.9016.216.2202.52-300.00600SO6002020220513.253-4018.15024.224.210.1506.056.0590.75(5)回水立管局都阻力管段合流三通分流三通四通90。彎頭散熱器閘閥突然擴(kuò)大突然縮小動(dòng)壓局部阻力總計(jì)北向立管m2-318.1500024.2012.106.0554.45321.3753-40030.4051.2025.6012.0115.24—50043.35057.B21.67520.9014.45151.725總計(jì)北向立管IV2-34S.60.000064.8032.4016.2145.8413.5253-400.00600000400201004—500.001B.1524.224.29.07512.106.0507.725(6)總N且力沿程阻力局部阻力總阻力不平衡率北向立管m2024.41170.4253194.799S.2S%北向立管w2023.7926.7752950.495(7)通過(guò)以上計(jì)算可知立管川和立管“不平衡率為8.28%小于15%,滿足設(shè)計(jì)要求。
供熱工程課程設(shè)計(jì)計(jì)算書-19-南向環(huán)路水力平衡計(jì)算1)計(jì)算簡(jiǎn)圖如下所示:2)對(duì)立管111和立管1的全部阻力進(jìn)行計(jì)算,計(jì)算過(guò)程如5.2所示,現(xiàn)僅列表格如下所示:2.南向水力平衡計(jì)算選取立管HI和立管I進(jìn)行平衡計(jì)(1)水平支管沿程阻力,包括供水和回水,所得結(jié)果X2管段號(hào)熱負(fù)荷Q(W)水流量G(ks/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力總沿程阻力南向立管I301(1)1120.93S.562.5100.1571.1111.25177.775631.266301(2)1120.93S.562.5200.1571.1111.25177.775201(1)893.5130.742.5100.1246.017.2115.025201⑵893.5130.742.5100.1246.017.2115.025門廳⑵1543.3753.090.B150.0S10.623.2B.496門廳(3)1543.3753.093.5150.OS10.623.237.17管段號(hào)熱負(fù)荷Q(W)水流量G(ks/h)管長(zhǎng)L(m)管徑流速比摩阻動(dòng)壓沿程阻力南向立管山3031279.1144.001.4100.1093.3716.2130.71B591.2343031279.1144.001.4100.1093.3716.2130.71B204741.6625.511.4100.135.45549.632051003.534.521.4100.1457.99.881.061011130.963S.911.4100.1571.1111.2599.55
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024年第三季度心理安全教育資源語(yǔ)義增強(qiáng)技術(shù)規(guī)范
- 學(xué)前教育學(xué)課本
- 家庭教育專業(yè)答辯
- 雅安市天全縣2025年一級(jí)建造師市政工程全真模擬試題含解析
- 健康安全教育主題班會(huì)
- 企業(yè)管理的數(shù)字化轉(zhuǎn)型路徑計(jì)劃
- 教學(xué)工作計(jì)劃總結(jié)報(bào)告輸出總結(jié)
- 月工作總結(jié)的重要性計(jì)劃
- 學(xué)習(xí)物流優(yōu)化算法的關(guān)鍵要素試題及答案
- 科技創(chuàng)新與人力資源發(fā)展計(jì)劃
- 2023年廣東省深圳市中考物理試卷真題(含答案詳解)
- 新概念英語(yǔ)第二冊(cè)-Lesson-56-Faster-than-sound-課件
- 管網(wǎng)漏水控制系統(tǒng)流程圖
- 中國(guó)馬克思主義與當(dāng)代思考題(附答案)
- 信息經(jīng)濟(jì)學(xué)案例教學(xué)資料及內(nèi)容
- 人教版小學(xué)道德與法治感受生活中的法律教學(xué)設(shè)計(jì)省一等獎(jiǎng)
- 急診與災(zāi)難醫(yī)學(xué)-心肺腦復(fù)蘇 完整版
- 非遺文化介紹推廣課件
- 氧氣吸入(中心供氧)課件
- 【電氣專業(yè)】15D501建筑物防雷設(shè)施安裝
- 銳捷產(chǎn)品線拓?fù)鋱D標(biāo)合集
評(píng)論
0/150
提交評(píng)論