第6章截面設(shè)計6.1內(nèi)力調(diào)整6.1.1梁端內(nèi)力調(diào)整為了滿足建筑物的延性設(shè)計,使結(jié)構(gòu)在地震中吸收更多的能量,設(shè)計結(jié)構(gòu)應(yīng)使梁最終的破壞形態(tài)為彎矩破壞而非剪切破壞,故對其剪力設(shè)計值進行放大調(diào)整,簡稱強剪弱彎;抗規(guī)對應(yīng)的公式如下所示。—梁凈跨;—重力荷載代表值作用下簡支梁梁端剪力設(shè)計值;—有震組合下,梁端左右彎矩設(shè)計值;—框架梁端剪力放大系數(shù),其數(shù)值由抗震等級確定,三級、二級、一級分別對應(yīng)為1.1、1.2、1.3;表8-1梁端剪力強剪弱彎調(diào)整樓層凈跨ln(m)?vbMbl+Mbrg+q/2VGbV5F5.801.20265.5822.3277.67132.622.201.20546.5713.6818.06316.184F5.801.20545.3728.4398.94211.772.201.201279.7313.6217.98716.013F5.801.20820.8828.4398.94268.772.201.202043.0213.6217.981132.352F5.801.201016.8928.4398.94309.332.201.202566.5913.6217.981417.941F5.801.201168.9028.4398.94340.782.201.202589.2913.6217.981430.326.1.2柱端內(nèi)力調(diào)整(1)柱端彎矩的調(diào)整由于柱子為框架的承重構(gòu)件,基于延性設(shè)計理念,要確保柱子破壞晚于梁的破壞,簡稱強柱弱梁;抗規(guī)對應(yīng)的公式如下所示。、分別為節(jié)點處柱端、梁端彎矩設(shè)計值之和;—柱端彎矩放大系數(shù);其數(shù)值由抗震等級確定,四級、三級、二級、一級分別對應(yīng)為1.2、1.3、1.5、1.7;表8-2柱端彎矩調(diào)整樓層柱編號5F邊柱228.741.50-343.11-315.62中柱410.021.50-615.03-696.024F邊柱420.831.50-315.62-425.27中柱928.021.50-696.02-1077.313F邊柱567.021.50-425.27-507.27中柱1436.421.50-1077.31-1339.382F邊柱676.361.50-507.27-693.42中柱1785.841.50-1339.38-1521.501F邊柱817.241.50-532.44-1761.80中柱1793.191.50-1168.29-2320.12(2)柱端剪力的調(diào)整使結(jié)構(gòu)在地震中吸收更多的能量且柱子破壞前產(chǎn)生更大的變形,設(shè)計結(jié)構(gòu)應(yīng)使柱最終的破壞形態(tài)為彎矩破壞而非剪切破壞,故對其剪力設(shè)計值進行放大調(diào)整,簡稱強剪弱彎;抗規(guī)對應(yīng)的公式如下所示?!觾舾?;—柱上下端彎矩設(shè)計值;—柱端剪力增大系數(shù),其數(shù)值由抗震等級確定,四級、三級、二級、一級分別對應(yīng)為1.1、1.2、1.3、1.5;表8-3柱端剪力調(diào)整樓層柱編號V5F邊柱1.30658.733.55241.23中柱1.301311.043.55480.104F邊柱1.30740.893.55271.31中柱1.301773.333.55649.393F邊柱1.30932.533.55341.49中柱1.302416.693.55884.992F邊柱1.301200.683.55439.69中柱1.302860.883.551047.651F邊柱1.302294.244.85614.95中柱1.303488.424.85935.046.2梁截面設(shè)計6.2.1梁正截面受彎計算各樓層梁配筋計算方法一樣,取一層邊跨梁配筋計算,進行過程展示,并用表格的形式列出其余樓層梁配筋計算??蚣芰夯炷翞镃30,框架梁縱筋選用HRB400,箍筋選用HRB400;相應(yīng)的參數(shù):fc=14.3kN/m2、ft=1.43kN/m2、fy=360kN/m2、fyv=360kN/m2。表8-4梁構(gòu)件控制截面內(nèi)力樓層邊跨中跨MlM1MrVmaxMlM2Vmax5F-228.74102.44-162.71132.62-299.26-24.84316.184F-420.83141.95-305.70211.77-657.40-15.04716.013F-567.02151.43-432.79268.77-1039.39-14.831132.352F-676.36162.30-520.15309.33-1300.89-14.361417.941F-817.24233.09-522.30340.78-1318.39-24.731430.32(1)框架梁正截面受彎計算對于框架梁支座截面,由于彎矩為負彎矩,根據(jù)彎矩的方向可知,梁頂部受拉,底部受壓,故設(shè)計時按矩形截面;對于跨中截面,如跨中截面彎矩為正彎矩,其梁底受拉,梁頂受壓,設(shè)計時按T型截面設(shè)計,反之,按矩形截面設(shè)計。由規(guī)范可知T型截面受壓翼緣寬度計算公式如下所示。由于,不考慮。邊跨min(7200/3,300+6600-300)=2400mm中跨min(2400/3,300+6600-300)=800mm(1)邊跨跨中正截面設(shè)計彎矩M1=233.09kN.m,板厚h=120mm,取as=35mm,受壓翼緣寬度為2400mm;0.000001×14.3×2400×120×(750-35-0.5×120)=2697.55kN.m,大于跨中截面彎矩設(shè)計值,該截面為第一類T形截面。截面類型為第一類T型截面。1×14.3×2400×715×715.mm1000000×233.090.01331-(1-2×0.0133)^0.5=0.0134<0.5181×14.3×2400×715×0.0134=328819.92N328819.92/360=913.39mm2跨中最小配筋率為max(0.25,55×1.43/360)=0.25%0.01×0.25×300×750=562.5mm2邊跨跨中梁底選配6C16(1206mm2)。(2)邊跨左支座正截面設(shè)計彎矩M左=-817.24kN.m,取as=60mm,ho=750-60=690mm;1×14.3×300×690×690=2042469000N.mm1000000×817.24/2042469000=0.40011-(1-2×0.4001)^0.5=0.518<0.5181×14.3×300×690×0.518=1533331.8N1533331.8/360=4259.26mm2支座截面最小配筋率為max(0.3,65×1.43/360)=0.3%0.01×0.3×300×750=675mm2邊跨左支座梁頂選配8C25(3927mm2)(3)邊跨右支座正截面設(shè)計彎矩M左=-522.3kN.m,取as=60mm,ho=750-60=690mm;1×14.3×300×690×690=2042469000N.mm1000000×522.3/2042469000=0.25571-(1-2×0.2557)^0.5=0.301<0.5181×14.3×300×690×0.301=890990.1N890990.1/360=2474.97mm2支座截面最小配筋率為max(0.3,65×1.43/360)=0.3%0.01×0.3×300×750=675mm2邊跨左支座梁頂選配8C25(3927mm2)。表8-5框架梁正截面計算樓層截面配筋配筋面積1F邊跨左-817.240.40.5183407.46758C2539271.75%邊跨中233.090.0130.013886.1562.56C1612060.54%邊跨右-522.300.2560.3012475.06758C2539271.75%中跨左-1318.390.4850.5183407.46758C2539271.75%中跨中-24.730.0110.01193.7562.56C1612060.54%2F邊跨左-676.360.3310.4193445.26758C2539271.75%邊跨中162.300.0090.009613.5562.56C1612060.54%邊跨右-520.150.2550.32466.86758C2539271.75%中跨左-1300.890.4750.5183407.46758C2539271.75%中跨中-14.360.0070.00759.6562.56C1612060.54%3F邊跨左-567.020.2780.3342746.36758C2539271.75%邊跨中151.430.0090.009613.5562.56C1612060.54%邊跨右-432.790.2120.2411981.66758C2539271.75%中跨左-1039.390.4650.5183407.46758C2539271.75%中跨中-14.830.0070.00759.6562.56C1612060.54%4F邊跨左-420.830.2060.2331915.86758C2539271.75%邊跨中141.950.0080.008545.3562.56C1612060.54%邊跨右-305.700.150.1631340.36758C2539271.75%中跨左-657.400.3220.4033313.76758C2539271.75%中跨中-15.040.0070.00759.6562.56C1612060.54%5F邊跨左-228.740.1120.119978.56758C2539271.75%邊跨中102.440.0060.006409.0562.56C1612060.54%邊跨右-162.710.080.083682.56758C2539271.75%中跨左-299.260.1470.161315.66758C2539271.75%中跨中-24.840.0110.01193.7562.56C1612060.54%6.2.2梁斜截面受剪計算(1)受剪截面的驗算邊跨梁:5800/750=7.73>2.50.001×0.2×14.3×300×715=613.47kN340.78<613.47,故滿足截面要求。中跨梁:2200/750=2.93>2.50.001×0.2×14.3×300×715=613.47kN1430.32<613.47,故滿足截面要求。(2)斜截面受剪計算由規(guī)范可知,斜截面受剪承載力應(yīng)滿足如下要求;其中,;梁混凝土等級為C30,箍筋為HPB300,ft=1.43kN/m2,fyv=270kN/m2。0.001×0.6×0.7×1.43×300×715/0.85=151.56kN時,按構(gòu)造配筋,反之,按計算配筋??蚣芸拐鸬燃墳槎墸蚣芰鹤钚∨涔柯师裺v≥0.28ft/fyv=0.148%。加密區(qū)的長度,是由抗震等級決定,一級抗震時,其長度為max(2h,500),二三四級抗震時,長度為max(1.5h,500)。加密區(qū)長度為l。表8-6框架梁斜截面計梁Vbb×hoftfyvASV/sl加密區(qū)非加密實配ASV/s%1F邊跨340.78300×7151.432700.8331070A8@100A8@1500.670.223中跨1430.32300×7151.432705.631070A12@100A12@1002.2610.7542F邊跨309.33300×7151.432700.6951070A8@100A8@1500.670.223中跨1417.94300×7151.432705.5761070A12@100A12@1002.2610.7543F邊跨268.77300×7151.432700.5161070A8@100A8@1500.670.223中跨1132.35300×7151.432704.3181070A12@100A12@1002.2610.7544F邊跨211.77300×7151.432700.2651070A8@100A8@1500.670.223中跨716.01300×7151.432702.4851070A12@100A12@1002.2610.7545F邊跨132.62300×7151.43270構(gòu)造1070A8@100A8@1500.670.223中跨316.18300×7151.432700.7251070A12@100A12@1002.2610.7546.3柱截面設(shè)計框架柱軸壓比:表8-7柱軸壓比驗算層號柱N(KN)fcb×hμμN5F邊柱393.3814.3800×8000.0430.75中柱491.8114.3800×8000.0540.754F邊柱896.1714.3800×8000.0980.75中柱1344.6214.3800×8000.1470.753F邊柱1400.0914.3800×8000.1530.75中柱2463.3914.3800×8000.2690.752F邊柱1905.3514.3800×8000.2080.75中柱3785.7314.3800×8000.4140.751F邊柱2439.7714.3800×8000.2670.75中柱5117.5514.3800×8000.5590.756.3.1框架柱正截面計算柱混凝土等級、縱筋、箍筋分別為C30、HRB400、HPB300。相應(yīng)參數(shù)為fc=14.3kN/m2,ft=1.43kN/m2,fy=360kN/m2,fyv=270kN/m2。根據(jù)柱M-N包絡(luò)圖可知,對于柱截面設(shè)計要取軸力最大、軸力最小以及彎矩絕對值最大三組控制內(nèi)力對其進行計算。根據(jù)受壓區(qū)高度x的不同,柱截面的受力類型可以分為大偏心受壓和小偏心受壓。大偏心受壓時:,此時受壓區(qū)鋼筋屈服;小偏心受壓時:以三層邊柱為例,對其過程進行展示,并以表格形式列出其余樓層各柱的配筋計算。表8-8三層邊柱柱內(nèi)力設(shè)計值內(nèi)力軸力最大軸力最小彎矩絕對值最大Nt(kN)1306.06632.751112.31Mt(kN.m)98.88-425.27425.27Nb(kN)1400.09702.181181.75Mb(kN.m)95.31-507.27507.27(1)軸力最大組合95.31/98.88=0.9640.7+0.3×-1×0.964=0.7(小于0.7時,取0.7)0.001×0.5×14.3×800×800=4576kN4576/1306.06=1(大于1時,取1)max(800/30,20)=26.7mm1300×(98.88×1000/1306.06+26.7)/765=174.031+1/174.03×5.382×1=1.170.7×1.17×98.88=80.98kN.m1000×80.98/1306.06=62mm62+26.7+800/2-35=453.7mm0.518×765=396.3mm103×1306.06/14.3/800=114.2mm≤396.3mm,故框架柱為大偏心受壓。1306.06×1000×453.7-14.3×800×114.2×(765-0.5×114.2)=-332275117N.mm360×(765-35)=262800N/mm-332275117/262800=-1264mm2(2)軸力最小組合425.27/507.27=0.8380.7+0.3×-1×0.838=0.7(小于0.7時,取0.7)0.001×0.5×14.3×800×800=4576kN4576/702.18=1(大于1時,取1)max(800/30,20)=26.7mm1300×(507.27×1000/702.18+26.7)/765=1273.021+1/1273.02×5.382×1=1.020.7×1.02×-507.27=-362.19kN.m1000×362.19/702.18=516mm516+26.7+800/2-35=907.7mm0.518×765=396.3mm103×702.18/14.3/800=61.4mm≤396.3mm,故框架柱為大偏心受壓。702.18×1000×907.7-14.3×800×61.4×(765-0.5×61.4)=121584717N.mm360×(765-35)=262800N/mm121584717/262800=463mm2(3)彎矩絕對值最大組合425.27/507.27=0.8380.7+0.3×0.838×-1=0.7(小于0.7時,取0.7)0.001×0.5×14.3×800×800=4576kN4576/1181.75=1(大于1時,取1)max(800/30,20)=26.7mm1300×(507.27×1000/1181.75+26.7)/765=774.821+1/774.82×5.382×1=1.040.7×1.04×507.27=369.29kN.m1000×369.29/1181.75=312mm312+26.7+800/2-35=703.7mm0.518×765=396.3mm1181.75×1000/14.3/800=103.3mm≤396.3mm,故框架柱為大偏心受壓。1181.75×1000×703.7-14.3×800×103.3×(765-0.5×103.3)=-11405314N.mm360×(765-35)=262800N/mm-11405314/262800=-43mm2表8-9軸力最大組合框架柱配筋計算層號柱截面內(nèi)力M1/M2eaMe0e判斷單邊配筋ρ1F邊柱頂M70.85-0.6430.7126.71.574.3932423.7396.3202.6大偏壓-211512808C252.150.85N2317.33邊柱底M110.230.7126.71.4108.0344435.7396.3213.3大偏壓-20651280N2439.77中柱頂M795.32-0.3490.70.9126.71.14634.67126517.7396.3439.4小偏壓-63512808C252.150.85N5027.13中柱底M2275.760.70.89426.71.051672.68327718.7396.3447.3小偏壓36851280N5117.552F邊柱頂M102.45-0.8090.7126.71.286.0648439.7396.3158.3大偏壓-170012808C252.150.85N1811.32邊柱底M126.660.7126.71.18104.6255446.7396.3166.6大偏壓-17031280N1905.35中柱頂M968.83-0.9930.7126.71.06718.87193584.7396.3324.9大偏壓-24912808C252.150.85N3716.3中柱底M961.860.7126.71.06713.7189580.7396.3330.9大偏壓-2811280N3785.733F邊柱頂M98.88-0.9640.7126.71.1780.9862453.7396.3114.2大偏壓-126312808C252.150.85N1306.06邊柱底M95.310.7126.71.1878.7356447.7396.3122.4大偏壓-13631280N1400.09中柱頂M849.22-0.8980.7126.71.04618.23258649.7396.3209.3大偏壓-9512808C252.150.85N2393.95中柱底M762.330.7126.71.05560.31227618.7396.3215.3大偏壓-3591280N2463.394F邊柱頂M93-0.9990.7126.71.1272.9191482.7396.370.1大偏壓-75312808C252.150.85N802.14邊柱底M93.10.7126.71.1373.6482473.7396.378.3大偏壓-8581280N896.17中柱頂M631.03-0.8080.7126.71.03454.97357748.7396.3111.5大偏壓18712808C252.150.85N1275.18中柱底M510.090.7126.71.04371.35276667.7396.3117.5大偏壓-1951280N1344.625F邊柱頂M116.63-0.8150.7126.71.0484.91284675.7396.326.2大偏壓-8912808C252.150.85N299.35邊柱底M95.050.7126.71.0670.53179570.7396.334.4大偏壓-2651280N393.38中柱頂M310.68-0.5580.7126.71.02221.83520911.7396.337.3大偏壓26912808C252.150.85N426.71中柱底M173.360.7126.71.04126.21257648.7396.343大偏壓-1791280N491.81表8-10軸力最小組合框架柱配筋計算層號柱截面內(nèi)力M1/M2eaMe0e判斷單邊配筋ρ1F邊柱頂M-532.44-0.3020.7126.71.05-391.34404795.7396.384.8大偏壓26612808C252.150.85N969.58邊柱底M-1761.80.7126.71.02-1257.9311871578.7396.392.7大偏壓34651280N1060.01中柱頂M-1168.29-0.5040.7-2.44726.71.12-915.94-490-98.3396.3-163.5大偏壓372412808C252.150.85N-1870.4中柱底M-2320.120.7-2.57126.71.06-1721.53-967-575.3396.3-155.6大偏壓38031280N-1779.982F邊柱頂M-507.27-0.7320.7126.71.03-365.74450841.7396.371大偏壓34812808C252.150.85N812.47邊柱底M-693.420.7126.71.02-495.1561952.7396.377.1大偏壓7601280N881.9中柱頂M-1339.38-0.880.7-3.73726.71.06-993.82-812-420.3396.3-107大偏壓276912808C252.150.85N-1224.39中柱底M-1521.50.7-3.96226.71.05-1118.3-968-576.3396.3-101大偏壓31211280N-1154.953F邊柱頂M-425.27-0.8380.7126.71.02-303.64480871.7396.355.3大偏壓32512808C252.150.85N632.75邊柱底M-507.270.7126.71.02-362.19516907.7396.361.4大偏壓4631280N702.18中柱頂M-1077.31-0.8040.7-8.08726.71.07-806.91-1426-1034.3396.3-49.5大偏壓292812808C252.150.85N-565.87中柱底M-1339.380.7-9.21826.71.06-993.82-2002-1610.3396.3-43.4大偏壓35281280N-496.434F邊柱頂M-315.62-0.7420.7126.71.02-225.35567958.7396.334.7大偏壓32112808C252.150.85N397.5邊柱底M-425.270.7126.71.02-303.646561047.7396.340.4大偏壓5351280N462.59中柱頂M-723.75-0.6720.7-41.21826.71.11-562.35-5065-4673.3396.3-9.7大偏壓230012808C252.150.85N-111.02中柱底M-1077.310.7-110.05326.71.07-806.91-19406-19014.3396.3-3.6大偏壓31291280N-41.585F邊柱頂M-343.110.920.976126.71.01-338.2220692460.7396.314.3大偏壓105912808C252.150.85N163.5邊柱底M315.620.976126.71.01311.1313611752.7396.320大偏壓8681280N228.6中柱頂M-615.03-0.8840.7126.71-430.521010610497.7396.33.7大偏壓157912808C252.150.85N42.6中柱底M-696.020.7126.71-487.2145244915.7396.39.4大偏壓17031280N107.7表8-11彎矩絕對值最大組合框架柱配筋計算層號柱截面內(nèi)力M1/M2eaMe0e判斷單邊配筋ρ1F邊柱頂M532.44-0.3020.7126.71.1409.98196587.7396.3183.1大偏壓-69012808C252.150.85N2094.43邊柱底M1761.80.7126.71.031270.26581972.7396.3191大偏壓25231280N2184.85中柱頂M-1168.29-0.5040.7-2.44726.71.12-915.94-490-98.3396.3-163.5大偏壓372412808C252.150.85N-1870.4中柱底M-2320.120.7-2.57126.71.06-1721.53-967-575.3396.3-155.6大偏壓39031280N-1779.982F邊柱頂M507.27-0.7320.7126.71.05372.84234625.7396.3139.2大偏壓-42012808C252.150.85N1592.57邊柱底M693.420.7126.71.04504.81304695.7396.3145.3大偏壓161280N1662.01中柱頂M-1339.38-0.880.7-3.73726.71.06-993.82-812-420.3396.3-107大偏壓276912808C252.150.85N-1224.39中柱底M-1521.50.7-3.96226.71.05-1118.3-968-576.3396.3-101大偏壓31211280N-1154.953F邊柱頂M425.27-0.8380.7126.71.04309.6278669.7396.397.2大偏壓-19512808C252.150.85N1112.31邊柱底M507.270.7126.71.04369.29312703.7396.3103.3大偏壓-421280N1181.75中柱頂M-1077.31-0.8040.7-8.08726.71.07-806.91-1426-1034.3396.3-49.5大偏壓292812808C252.150.85N-565.87中柱底M-1339.380.7-9.21826.71.06-993.82-2002-1610.3396.3-43.4大偏壓35281280N-496.434F邊柱頂M328.44-0.7720.7126.71.03236.81382773.7396.354.2大偏壓8512808C252.150.85N619.86邊柱底M425.270.7126.71.03306.62448839.7396.359.9大偏壓2701280N684.95中柱頂M-723.75-0.6720.7-41.21826.71.11-562.35-5065-4673.3396.3-9.7大偏壓230012808C252.150.85N-111.02中柱底M-1077.310.7-110.05326.71.07-806.91-19406-19014.3396.3-3.6大偏壓31291280N-41.585F邊柱頂M343.11-0.920.7126.71.01242.5810331424.7396.320.5大偏壓60012808C252.150.85N234.87邊柱底M315.620.7126.71.02225.357511142.7396.326.2大偏壓4471280N299.97中柱頂M-615.03-0.8840.7126.71-430.521010610497.7396.33.7大偏壓157912808C252.150.85N42.6中柱底M-696.020.7126.71-487.2145244915.7396.39.4大偏壓17031280N107.76.3.2框架柱斜截面計算(1)柱截面驗算以首層邊柱為例,柱截面b×h為800×800mm,剪力設(shè)計值為614.95kN。ho=800-35=765mm首層結(jié)構(gòu)高度為5.6m,故首層凈高Hn=5.6-0.75=4.85m剪跨比4.85/2/0.765=3當時,取。剪力應(yīng)滿足0.20×14.3×800×765/1000=1750.32kN614.95<1750.32kN,滿足要求。(2)柱截面驗算柱截面剪力設(shè)計值應(yīng)滿足如下公式:N為有震組合下(與剪力設(shè)計值V同一組合)柱軸力設(shè)計值,且該值≤。表8-12框架柱斜截面計算層號柱NVmaxh0fyvftλAsv/s實配箍筋類型5F邊柱234.87241.237652701.432.32<0A10@200/1000.86復(fù)合0.6中柱42.6480.17652701.432.320.62A10@200/1000.86復(fù)合0.64F邊柱619.86271.317652701.432.32<0A10@200/1000.86復(fù)合0.6中柱-111.02649.397652701.432.321.36A10@200/1000.86復(fù)合0.63F邊柱1112.31341.497652701.432.32<0A10@200/1000.86復(fù)合0.6中柱-565.87884.997652701.432.322.46A10@200/1000.86復(fù)合0.62F邊柱1592.57439.697652701.432.320.04A10@200/1000.86復(fù)合0.6中柱-1224.391047.657652701.432.323.3A10@200/1000.86復(fù)合0.61F邊柱2094.43614.957652701.433.000.85A10@200/1000.86復(fù)合0.6中柱-1870.4935.047652701.433.003.24A10@200/1000.86復(fù)合0.6第7章板截面設(shè)計圖9-1板的平面布置圖7.1荷載計算表9-1樓板面荷載板區(qū)隔編號gk(kN/m2)qk(kN/m2)g(kN/m2)q(kN/m2)g+pg+p/2p/2A3.962.55.153.758.97.0251.875B3.963.55.155.2510.47.7752.625恒載分項系數(shù)為1.3,活載分項系數(shù)1.5。7.2板的彎矩計算根據(jù)板的寬長比查表可以求出雙向板的彎矩系數(shù)。對于編號A板,寬長比為0.458,板的跨中系數(shù)為0.0409、0.0089,支座系數(shù)為-0.0836、-0.0569,周邊簡支時的跨中系數(shù)為0.0965、0.0174。對于編號B板,寬長比為0.364,板的跨中系數(shù)為0.04、0.0038,支座系數(shù)為-0.0829、-0.057,周邊簡支時的跨中系數(shù)為0.0965、0.0174。雙向板跨中彎矩雙向板支座彎矩其中、、分別為跨中彎矩系數(shù)、支座彎矩系數(shù)、簡支時跨中彎矩系數(shù)。表9-2彎矩計算區(qū)格截面彎矩(kN.m)彎矩調(diào)整(kN.m)A跨中(短板)0.0409×7.025×3.32+0.0965×1.875×3.32=5.15.1+1.04×0.2=5.31跨中(長板)0.0089×7.025×3.32+0.0174×1.875×3.32=1.041.04+5.1×0.2=2.06支座(短板)-0.0836×8.9×3.32=-8.1-8.1支座(長板)-0.0569×8.9×3.32=-5.51-5.51B跨中(短板)0.04×7.775×2.42+0.0965×2.625×2.42=3.253.25+0.43×0.2=3.34跨中(長板)0.0038×7.775×2.42+0.0174×2.625×2.42=0.430.43+3.25×0.2=1.08支座(短板)-0.0829×10.4×2.42=-4.97-4.97支座(長板)-0.057×10.4×2.42=-3.41-3.417.3板的配筋計算板的厚度h=120mm,根據(jù)環(huán)境類別取板的保護層厚度為15mm,假定板底鋼筋直徑d為10mm,短邊方向跨中配筋計算時,板的有效高度ho=h-15-d/2=100mm;由于板底為雙向受力鋼筋,短邊鋼筋在下,故長邊方向跨中配筋計算時,板的有效高度ho=h-15-d-d/2=90mm。。板配筋不僅要滿足計算的要求還得滿足最小配筋率的要求。由規(guī)范可知板的最小配筋率。最小配筋面積為0.2×0.01×1000×120=240mm2板配筋計算按如下公式計算:;;表9-3板配筋計算A區(qū)格跨中B區(qū)格跨中支座短邊方向長邊方向短邊方向長邊方向A/AA/BB/BM5.312.063.341.08-8.1-5.51-3.410.0370.0180.0230.0090.0570.0390.0240.9810.9910.9880.9950.9710.9800.988150.3664.1693.933.5231.72156.1895.87實際配筋C8@200C8@200C8@200C8@200C8@200C8@200C8@200配筋面積(mm2)251251251251251251251(mm2)240240240240240240240滿足要求第8章樓梯結(jié)構(gòu)設(shè)計由樓梯平面和剖面可知,標準層踏步尺寸為163.6×270mm,標準層層高為3300mm。樓梯梁板混凝土等級為C30,梯柱混凝土等級為C30,梯板鋼筋為HRB400,梯梁梯柱縱向受力鋼筋與箍筋級別同框架梁柱鋼筋。樓梯面層為30mm厚現(xiàn)制水磨石面層,底部為20mm厚水泥石灰砂漿,樓梯活載為3.5kN/m2。8.1梯段板設(shè)計計算(1)梯板厚度的估算b=(1592+3002)^0.5=339.5mm,故cosα=300/339.5=0.884梯板的水平投影長度ln=3900mm,梯板的斜向凈長為ln/cosα=3900/0.884=4412mm;梯板厚度h=(1/30~1/25)×4412=147.1~176.5mm,取h=150mm(2)荷載統(tǒng)計表10-1梯板荷載計算荷載種類荷載標準值(kN/m2)分項系數(shù)荷載設(shè)計值(kN/m2)永久荷載30mm水磨石面層0.65×(0.159+0.3)/0.3=0.995————踏步自重0.159×0.5×25=1.988————梯板自重0.15×25/0.884=4.242————板底粉刷0.02×17/0.884=0.385————小計7.611.3g=7.61×1.3=9.893可變荷載3.51.5q=3.5×1.5=5.25合計————15.143(3)跨度計算梯段板單跨兩端與支撐構(gòu)件整澆,lo=ln=3900mm。。(4)內(nèi)力計算跨中彎矩15.143×3.92/10=23.03kN.m150-25=125mm,b=1000mm1000000×23.03/14.3/1252=0.1031-(1-2×0.103)^0.5=0.1090.5×(1+(1-2×0.08)^0.5)=0.9581000000×23.03/0.946/360/125=541mm20.2%0.2×150×1000×0.01=300mm2板底受力鋼筋選用C12@200(AS=565mm2),梯板支座筋選用C8@150(335mm2),分布鋼筋C8@300,每踏步下一根。。8.2平臺板設(shè)計計算(1)平臺板厚度的估算平臺板ln=1900mm;平臺板厚度h≥1/30ln=63.33mm,取h=100mm(2)荷載統(tǒng)計表10-2平臺板荷載計算荷載種類荷載標準值(kN/m2)分項系數(shù)荷載設(shè)計值(kN/m2)永久荷載30mm水磨石面層0.65————平臺板自重0.1×25=2.5————板底粉刷0.02×17=0.34————小計3.491.3g=3.49×1.3=4.537可變荷載3.51.5q=3.5×1.5=5.25合計————9.787(3)跨度計算平臺板lo=ln=1900mm。。(4)內(nèi)力計算跨中彎矩9.787×1.92/8=4.42kN.m100-15-5=80mm,b=1000mm1000000×4.42/14.3/1000/802=0.0481-(1-2×0.048)^0.5=0.0490.5×(1+(1-2×0.048)^0.5)=0.9751000000×4.42/0.975/360/80=157mm20.2×100×1000×0.01=200mm2板底受力鋼筋C8@200(AS=251mm2),分布鋼筋C8@200(AS=251mm2),布置時雙層雙向拉通鋼筋。8.3平臺梁設(shè)計計算(1)平臺梁截面估算平臺梁跨度lc=2700mm;梁高h≥1/12lc=225mm,取h=200mm,b=400mm。(2)荷載統(tǒng)計表10-3梯梁荷載計算荷載種類荷載標準值(kN/m)分項系數(shù)荷載設(shè)計值(kN/m)永久荷載平臺板傳遞荷載3.49×1.9/2=3.32————梯板傳遞荷載7.61×3.9/2=14.84————平臺梁自重0.2×(0.4-0.1)×25=1.5————梁底抹灰自重0.02×(0.4-0.1)×2×17=0.2————小計19.861.3g=19.86×1.3=25.82可變荷載3.5×(1.9/2+3.9/2+0.2)=10.851.5q=10.85×1.5=16.28合計————42.1(3)跨度計算平臺板lo=lc=2700mm,凈跨為ln=2700-200=2500mm(4)內(nèi)力計算跨中彎矩42.1×3.92/8=80.04kN.m42.1×0.5×2.5=52.63kN400-45=355mmb=200mm80.04×1000000/14.3/200/3652=0.211-(1-2×0.21)^0.5=0.2380.5×(1+(1-2×0.21)^0.5)=0.8811000000×80.04/0.881/360/365=691mm20.2×200×400×0.01=160mm2梁底受力鋼筋選用3C18(As=763mm2),梁頂配筋與梁底一致。。0.7×1.43×200×365/1000=73.07kNV=52.63kN<73.07kN,故按構(gòu)造要求配置箍筋;×0.28=0.28×1.43/360=0.111%故梯梁箍筋選配A8@200,實際配箍率為0.502%,故滿足要求。。第9章柱下獨立基礎(chǔ)設(shè)計依據(jù)地質(zhì)土層的情況,本設(shè)計基礎(chǔ)采用獨立基礎(chǔ);基礎(chǔ)持力層選用黏土,未修正地基承載力特征值為250kPa;根據(jù)內(nèi)力組合表,查到邊柱和中柱控制內(nèi)力,分別對其進行基礎(chǔ)設(shè)計;控制內(nèi)力如下表所示。混凝土采用C30,鋼筋采用HRB400,相應(yīng)的參數(shù):fc=14.3kN/m2、ft=1.43kN/m2、fy=360kN/m2。表11-1一層柱底控制內(nèi)力控制內(nèi)力柱編號N(kN)M(kN.m)V(kN)邊柱標準值1823.0331.55-11.27設(shè)計值2439.77110.23-25.78中柱標準值1932.09-26.089.31設(shè)計值5117.552275.76-438.769.1邊柱獨立基礎(chǔ)設(shè)計9.1.1邊柱基礎(chǔ)底面尺寸確定基礎(chǔ)埋深為基底至室外地面的高度,假設(shè)基礎(chǔ)高度為800m,故基礎(chǔ)埋深d為0.8+0.05=0.85m,由持力層土層參數(shù)查規(guī)范可知:深度修正系數(shù)為1.6?;滓陨贤恋募訖?quán)平均重度:17.4kN/m3深度修正后地基承載力特征值:250+1.6×17.4×(0.85-0.5)=259.74kpa0.85+0.75/2=1.225m邊柱柱底軸力標準值為:1823.03kN邊柱基底計算面積1823.03/(259.74-20×1.225)=7.75m2,由于柱底偏心距的存在,基底計算面積增大10%,即1.1×7.75=8.53m,一般l/b=(1.2~2.0),取基礎(chǔ)長度為3.5m,寬度為2.5m,基底面積為8.75>8.53mm2,滿足要求,另外基礎(chǔ)寬度小于3m,無需進行寬度修正。9.1.2持力層承載力驗算20×1.225×8.75=214.38kN基底彎矩31.55+11.27×0.8=40.6kN.m偏心距40.6/2037.41=0.02m<L/6=3.5/6=0.583m?;灼骄鶋毫χ担?(214.38+1823.03)/8.75=232.85<fa=259.74kpa,故滿足要求?;走吘壍淖畲髩毫χ?232.85×(1+6×0.02/3.5)=240.83<1.2fa=311.69kpa,故滿足要求。9.1.3基礎(chǔ)高度驗算(1)計算基底凈反力邊柱柱底內(nèi)力設(shè)計值F=2439.77kN、V=-25.78kN、M=110.23kN.m基底彎矩設(shè)計值110.23-25.78×0.8=89.61kN.m(110.23-25.78×0.8)/2439.77=0.037m 基礎(chǔ)邊緣處的最大和最小凈反力為:2439.77×(1±6×0.037/3.5)/8.75=296.52kpa/261.15kpa基礎(chǔ)沖切驗算基礎(chǔ)受沖切承載力應(yīng)滿足如下公式:基礎(chǔ)有效高度ho=h-50=800-50=750mm0.8m0.8+2×0.75=2.3m0.5×(0.8+2.3)=1.55m由于h0小于800mm,故0.7×1×1.43×1550×750/1000=1163.66kN((2.5×(3.5-0.8-2×0.75)/2)-0.01=1.49m2296.52×1.49=441.81kN<1163.66kN,故滿足沖切驗算。由于,故滿足沖切驗算。9.1.4基礎(chǔ)配筋計算(1)柱邊(1-1截面):對于此處偏心荷載可以取和的平均值。圖11-1配筋驗算示意圖(3.5+0.8)×(296.52-261.15)/(2×3.5)=21.73kpa261.15+21.73=282.88kpa(296.52+282.88)/2=289.7kpa(3.5-0.8)2×(2×2.5+0.8)=42.28m3289.7×42.28/24=510.38kN.m0.9×750×360=243000N/mm510.38×1000000/243000=2100.3mm2每米寬配筋面積:2100.3/2.5=840.1mm2/m故每延米最小配筋面積為0.15%×1000×800=1200mm2/m。選配C18@200,面積為1272mm2/m>max(840.1mm2,1200mm2),滿足要求。(2)柱邊(2-2截面):(296.52+261.15)/2=278.84kpa(2.5-0.8)2×(2×3.5+0.8)=22.54m3278.84×22.54/24=261.9kN.m0.9×(750-18)×360=234900N/mm261.9×1000000/234900=1104.3mm2每米寬配筋面積:1104.3/3.5=315.5mm2/m,故每延米最小配筋面積為0.15%×1000×800=1200mm2/m。選配C18@180,面積為1414mm2/m>max(315.5mm2,1200mm2),滿足要求。9.2中柱獨立基礎(chǔ)設(shè)計9.2.1中柱基礎(chǔ)底面尺寸確定11-2中柱基礎(chǔ)計算簡圖中柱軸力標準值Fk=1932.09kN,合力F=2Fk=3864.18kN,l1=2400mm。對左中柱點彎矩取矩1932.09×2.4/3864.18=1.2mlo=(1/2~2/3)l1=1.2~1.6m,取lo為1.6m,故基礎(chǔ)長度l=2(xo+lo)=5.6m,基底壓力均勻分布。邊柱基底計算面積:3864.18/5.6/(259.74-20×1.225)=2.93m,取b=3m。9.2.2持力層承載力驗
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 代賬會計合同范例
- 冰激凌奶茶采購合同范例
- 不交金合同范例
- 企業(yè)房產(chǎn)贈與合同范例
- 做服裝合同范例
- 5000萬工程合同范例
- 保管使用合同范例
- 共同承包協(xié)議合同范例
- 公司股合同范例范例
- 個體空調(diào)售賣合同范例
- 2024社區(qū)工作者勞動合同
- 呼吸治療師進修匯報
- 老舊小區(qū)電梯更新改造方案
- 課件香港地理教學(xué)課件
- 2023年輔導(dǎo)員職業(yè)技能大賽試題及答案
- 2023年天津銀行招聘筆試真題
- 工程質(zhì)量控制流程圖
- 現(xiàn)代家政導(dǎo)論-課件 1.2.2認識現(xiàn)代家政的特點和功能
- 日語翻譯崗位招聘面試題與參考回答2025年
- 副總經(jīng)理招聘面試題及回答建議(某大型國企)
- 浙江省寧波市九校2023-2024學(xué)年高二下學(xué)期期末聯(lián)考數(shù)學(xué)試題
評論
0/150
提交評論