ICS29.240.01
F24
RecordNo.44815-2014DL
ElectricPowerIndustryStandardofthePeople’sRepublicofChina
DL/T1341—2014
TechnicalGuideforLiveWorkingon
±660kVDCTransmissionLine
IssueDate:March18,2014ImplementationDate:August1,2014
IssuedbyNationalEnergyAdministrationofthePeople’sRepublicofChina
I
Foreword
ThisstandardwascompiledinaccordancewiththetaskarrangedbyNoticeoftheNationalEnergy
AdministrationonIssuingtheFirstBatchofIndustryStandardFormulation(Revision)PlansintheEnergy
Sectorin2010(No.320oftheDepartmentofScienceandTechnologyoftheNationalEnergy
Administration).
ThisstandardwasproposedbytheChinaElectricityCouncil.
ThisstandardwaspreparedbytheNationalTechnicalCommitteeofStandardizationforLiveWorking.
Maindraftingorganizationsofthisstandard:ChinaElectricPowerResearchInstitute,StateGridShandong
ElectricPowerCompany,andStateGridShanxiElectricPowerCompany.
Maindraftersofthisstandard:LIUKai,HUYi,XIAOBin,LIUHongzheng,LIUTing,MENGHailei,YONG
Jun,NIUBiao,DONGYanwu,LIUYan,PENGYong,andSUZiming.
Duringtheprocessofimplementingthisstandard,relevantopinionsoradvicecanbefedbacktothe
StandardizationManagementCenteroftheChinaElectricityCouncil(No.1,Lane2,BaiguangRoad,Beijing,
100761).
II
TechnicalGuideforLiveWorkingon±660kVDCTransmissionLine
1Scope
Thisstandardspecifiesthetechnicalrequirementsandmattersneedingattentionforliveworkingon±660kVDC
transmissionlines,aswellasthetest,transportationandstorageoftheworkingtools.
Thisstandardisapplicabletoliveworkingon±660kVDCtransmissionlinesinareaswithanaltitudeof2000m
andbelow.
2Normativereferences
Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,
onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includingany
amendments)applies.
GB/T2900.55ElectrotechnicalTerminology—LiveWorking(eqvIEC60050—651)
GB/T6568ScreenClothesforLiveWorking(GB/T6568—2008,IEC60895:2002,MOD)
GB/T13035LiveWorking—InsulatingRopes
GB13398InsulatingHollowTubesandFoam-FilledTubesandSolidRodsforLiveWorking
GB/T14286LiveWorking—TerminologyforTools,EquipmentandDevices(GB/T14286—2008,IEC60743:
2001,MOD)
GB/T18037TechnicalRequirementsandDesignGuideforLiveWorkingTools
GB26859SafetyCodeofElectricPowerIndustry—PartofElectricLines
DL/T463InsulatorHolderforLiveWorking
DL/T876GuideofInsulationCoordinationforLiveWorking
1
DL/T878TestGuideoftheInsulatingToolforLiveWorking
DL/T966TechnicalGuideforLiveWorkinginTransmissionLine
DL/T974DepotofToolsforLive-Working
DL/T976PreventiveTestCodeofTools,DevicesandEquipmentforLiveWorking
3Termsanddefinitions
Forthepurposesofthisstandard,thetermsanddefinitionsgiveninGB/T2900.55andGB/T14286aswellasthe
followingapply.
3.1liveworkingonDCtransmissionline
live-linerepair,maintenance,andreplacementofpartscarriedoutonDCtransmissionlines
3.2potentialrod
metaltoolusedbyanequipotentialworkerwhenenteringorleavingequipotential,inordertoreducetheimpactof
dischargearconthehumanbodyandavoidpossibledamagetoconductiveclothingcausedbypulsedcurrent
3.3electricfieldshieldmask
maskmadeofconductivematerials,usedforelectricfieldprotectionoftheworker'sface,andconnectedwithother
screentoolsforintegraluse
4Generalrequirements
4.1Personnelrequirements
4.1.1Liveworkingworkersshallbeingoodhealthandfreefromphysicalandpsychologicalobstaclesthathinder
work.Theyshallhaveabasicknowledgeofelectricalprinciplesandpowerlines,masterthebasicprinciplesand
operatingmethodsofliveworking,andbefamiliarwiththescopeofapplicationandusingmethodsoftheworking
2
tools.TheyshallbefamiliarwithGB26859,DL/T966andthisstandard.Theyshallmasteremergencyrescue
methods,especiallytheelectricshockrescue.Theyshallreceivetheoreticalandoperationaltrainingfrom
specializedtraininginstitutions,passrelevantexaminationsandholdrelevantcertificates.
4.1.2Thepersoninchargeofthework(orthesafetyguardian)shallhaveatleast3yearsofactualworking
experienceinliveworkingonpowertransmissionlines,befamiliarwithequipmentconditions,havecertain
organizationalcapabilityandaccidenthandlingability,andpasstheexaminationafterspecialtraining.
4.2Institutionalrequirements
AccordingtoGB26859andthisstandard.
4.3Meteorologicalrequirements
4.3.1Liveworkingshallbecarriedoutingoodweather.Incaseofthunder,rain,snowandfog,liveworkingshall
notbecarriedout.Whenthewindforceisgreaterthanlevel5(10m/s),liveworkingshouldnotbecarriedout.
4.3.2Ifliveworkingisrequiredinweatherwithrelativehumiditygreaterthan80%,insulatingtoolswith
moisture-proofperformanceshallbeadopted,andthepossibilityofinsulationdegradationoftheinsulatingtools
underhighhumidityshallbeconsidered.
4.3.3Underspecialoremergentconditions,whenemergentlive-linerepairmustbecarriedoutinharshclimate,
relevantengineeringandtechnicalpersonnelandallworkingpersonnelshallbeorganizedtofullydiscussand
formulatereliablesafetymeasuresaccordingtothesiteclimateandworkingconditions,andtheemergentlive-line
repaircanbecarriedoutonlyaftertheapprovalofthechiefengineeroftheunitortheleaderinchargeof
productionoftheunit.Sufficientlightingfacilitiesshallbeprovidedfornightwork.
4.3.4Incaseofasuddenchangeofweatherduringliveworking,whichcanendangerpersonalorequipmentsafety,
theworkshallbestoppedimmediately.Undertheconditionofensuringpersonalsafety,thenormalworking
conditionsoftheequipmentshallberestoredassoonaspossibleorotherprotectivemeasuresshallbetaken.
4.4Otherrequirements
3
4.4.1Fornewliveworkingprojectsthataremorecomplicatedandmoredifficultandnewdevelopedtools,
scientifictestsshallbeconductedtoconfirmsafetyandreliability,andsafetymeasuresandoperationprocessplans
shallbeestablished,andthetoolscanbeoperatedonequipmentonlyaftertheapprovalofthechiefengineerofthe
unitortheleaderinchargeofproductionoftheunit.
4.4.2Thepersoninchargeofliveworkingshallcontactthedispatcherbeforetheworkstarts,andtheworkcanbe
startedonlyaftercontacting.WhenitisnecessarytodisableDCrestartprotectiondevices,thelicenseformalities
shallbeperformed.Aftertheworkisfinished,reportingtothedispatchershallbedoneintime.Itisstrictly
prohibitedtostoporresumetherestartprotectiondevicesatanappointedtime.
5Technicalrequirements
5.1Groundpotentialworking
5.1.1Whentheworkerworksatgroundpotential,theminimumworkingdistancebetweentheworkeratground
potentialonthetowerandtheliveconductorsshallmeettheprovisionsofTable1.
Table1Minimumworkingdistanceofgroundpotentialworking
Altitude/mMinimumworkingdistance/m
≤5004.2
500~10004.5
1000~15004.7
1500~20005.0
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan
0.5mandshallbeconsideredatwork.
5.1.2Theminimumeffectiveinsulationlengthofinsulatingtools,devicesandequipmentshallmeettheprovisions
ofTable2.
Table2Minimumeffectiveinsulationlengthofinsulatingtools,devicesandequipment
Altitude/mMinimumworkingdistance/m
≤5005.0
500~10005.3
1000~15005.6
1500~20005.9
4
5.2Barehandworking
5.2.1Duringbarehandworking,theminimumworkingdistancebetweentheequipotentialworkerandtheearthing
conductorsshallmeettheprovisionsofTable3.
Table3Minimumworkingdistanceofbarehandworking
Minimumworkingdistance/m
Distancebetweenthe
Distancebetweenthe
Altitude/mequipotentialworkerand
equipotentialworkerand
thetopcrossarmorthe
thesidetowerframe
topframe
≤5004.24.8
500~10004.55.1
1000~15004.75.3
1500~20005.05.6
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbeless
than0.5mandshallbeconsideredatwork.
5.2.2Whentheworkerentersorleavesequipotentialviainsulatingtoolsoralonginsulatorstrings,theminimum
combinedgapshallmeettheprovisionsofTable4.
Table4Minimumcombinedgap
Altitude/mMinimumcombinedgap/m
≤5004.3
500~10004.6
1000~15004.8
1500~20005.1
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan
0.5mandshallbeconsideredatwork.
5.2.3Whentheequipotentialworkerentersorleavesequipotentialalongtensioninsulatorstrings,thenumberof
insulatorsshort-circuitedbythehumanbodyshouldnotbemorethan4.Theminimumnumberofgoodinsulators
shallmeettheprovisionsofTable5afterthenumberofinsulatorsshort-circuitedbythehumanbodyandbad
insulatorsisdeductedfromthetensioninsulatorstrings.
5
Table5Minimumcombinedgapandtheminimumnumberofgoodinsulators
MinimumtotallengthoftheStructureheightofeachTheminimumnumberofgood
Altitude/m
goodinsulatorstring/minsulator/mminsulators
17026
19523
≤5004.4
20522
24019
17028
19525
500~10004.7
20523
24020
17030
19526
1000~15005.0
20525
24021
17032
19528
1500~20005.3
20526
24023
5.3Safetyprotection
5.3.1TheequipotentialworkershallwearTypeIIconductiveclothingandflameresistantunderwearaccordingto
GB/T6568.
5.3.2Theworkeratgroundpotentialonthetowershallwearafullsetofelectrostaticprotectiveclothingor
conductiveclothing.
5.3.3Theinsulatedoverheadgroundwireshallberegardedasaliveconductor,andtheworkersshallkeepa
distanceof0.6mfromit.Ifitisnecessarytoworkontheoverheadgroundwire,itshallbegroundedwellthrougha
dedicatedearthingcable.Themethodsandstepsforhangingordismantlingthededicatedearthingcableonthe
overheadgroundwirearethesameasthoseforhangingordismantlingtheearthingcableonapower-offline.After
hangingupthededicatedearthingcableandwearingafullsetofelectrostaticprotectiveclothingorconductive
clothing,theworkersmaycarryoutmaintenance.
5.3.4Foranopticalfibercompositeoverheadgroundwire(OPGW)groundedbyeachtowerfoundationorother
directlygroundedoverheadgroundwires,theworkersmaydirectlycarryoutmaintenanceworkbywearingafull
6
setofelectrostaticprotectiveclothingorconductiveclothing.Ifitisnecessarytodisconnectthedirectlygrounded
overheadgroundwiresfromtheground,theoverheadgroundwiresshallbehungwithearthingcablesbefore
maintenance.
5.3.5Beforeoverhaulinginthemiddleoftheoverheadgroundwirespan,inordertoensurehis/hersafety,the
workershallcheckwhethertheverticaldistancebetweenhim/herandtheliveconductorsbelowmeetsthe
minimumworkingdistancerequirementsaftertheoverheadgroundwireintheworklocationisloadedbyhim/her,
andwhetherthemechanicalstrengthoftheoverheadgroundwiremeetsrelevantrequirements.
5.3.6Whenworkingontheuni-polarpower-offside(theotherpoleisrunning),theworkershallwearafullsetof
electrostaticprotectiveclothingorconductiveclothing.
5.3.7Whenusinginsulatingropestotransferlargemetalobjects,theworkeratgroundpotentialoronthetower
shallgroundthemetalobjectsbeforetouchingthem.
5.3.8Withregardtolargemetalobjects(e.g.automobiles,etc.)insulatedfromthegroundandplacednearstrong
electricfields,attentionshallbepaidtoprotectingpeoplefrominducedelectricalinjury.Themetalobjectsmustbe
groundedbeforetheycanbetouched.
5.4Potentialtransfer
5.4.1Theequipotentialworkershallobtainpermissionfromthepersoninchargeoftheworkbeforepotential
transferandshallnotlosetheprotectionofthesafetybelt.
5.4.2ForpotentialtransferofDCtransmissionlines,thepotentialrodshouldbeused,whichshallbeinreliable
contactwithliveconductors.Beforeenteringequipotential,theworkershallcontactthepotentialrodquicklywith
theliveconductorsatadistanceofabout0.4mfromthem.Whenleavingequipotential,theworkershallcontactthe
potentialrodwiththeliveconductorsfirst,andthenwithdrawthepotentialrodquicklyafterleavingthelive
conductors0.4maway.
5.4.3Duringpotentialtransfer,theactionshallbesmooth,accurateandfast.
7
6Enterorleaveequipotential
6.1Enterorleaveequipotentialonasuspensiontower
6.1.1Whenenteringorleavingequipotentialonasuspensiontower,theworkershallnotenterorleave
equipotentialverticallyfromthecrossarmsoralongtheinsulatorstrings.Thehangingbasket(hangingchairand
hangingladder)method,theinsulatingflexibleladdermethodandothermethodsmaybeusedtoenterandleave
equipotential.
6.1.2Whentheworkerentersorleavesequipotential,alltheelectricalgapdistances(includingtheworking
distancesandthecombinedgaps)betweentheworkerandtheearthingconductorsandtheliveconductorsshall
meettherequirementsofTables3andTable4.
6.1.3Thehangingbaskets(hangingchairsandhangingladders)shallbestablysuspendedbyinsulatingslings,and
themovingspeedshallbestrictlycontrolledbyinsulatingpulleysetstoachieveauniformandslowspeed.The
lengthoftheinsulatingslingsforfixingshallbeaccuratelycalculatedoractuallymeasuredtoensurethatthe
highestpartofthehumanbodyshallnotexceedtheupperedgeofthegradingringontheconductorsidewhenthe
workerentersorleavesequipotential.
6.2Enterorleaveequipotentialonatensiontower
6.2.1Whenenteringorleavingequipotentialonatensiontower,theworkermayenterorleaveequipotentialalong
horizontaltensioninsulatorstringsorviaothermethods.
6.2.2Whentheworkermovesalongthehorizontaltensioninsulatorstrings,thepositionsofhis/herhandsandfeet
mustbekeptconsistent,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyandtoolsshallmeet
therequirementsofTable5.
6.2.3Theworker’ssafetyprotectionropeshallbetiedtotheinsulatorstringheldbyhis/herhandsandshallmove
synchronouslywithhim/her.
6.2.4Whenenteringorleavingequipotential,theworkershalltransferpotentialwhenmovingtoadistanceof
about0.4m(2~3insulators)fromtheliveconductorsbeforecarryingoutsubsequentoperations.
8
6.2.5Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheworker
andtheearthingconductorsandtheliveconductors,andthenumberofgoodinsulatorsshort-circuitedbythe
humanbodyortoolsshallmeettherequirementsofTable5.
7Mattersneedingattentionatwork
7.1Theworkersshallavoidexcessivebodymovementsduringliveworking.
7.2Insulatingtoolsshallbeusedtotransferarticlesbetweentheequipotentialworkerandthegroundpotential
worker.TheeffectivelengthoftheinsulatingtoolsshallmeettherequirementsofTable2.
7.3Theconductiveclothingshallbefreefromdamageandholes,andallpartsofitshallbeconnectedwelland
reliably.Whendamageandburrsarefound,itshallberepairedintime,anditcanbeusedonlyafterpassingthe
test.
7.4Beforetheinsulatingtoolsareused,aninsulationresistancetestershallbeusedtoconductsegmented
insulationtests.Thewidthofthemeasuringelectrodesis2cm,anditisrequiredthattheinsulationresistance
betweenevery2cmofmeasuringelectrodesshallnotbelessthan700MΩ.
7.5Theinsulatingtoolsshallbeprotectedfrommoistureandsurfacedamageanddirtwhenused.Theinsulating
toolstobeusedshallbeplacedonclean,dryandmoisture-proofpads.Whenfounddampenedorsurface-damaged
orsurface-dirty,theyshallbehandledintimeandcanbeusedonlyafterpassingthetest.
7.6Duringthework,bearingtoolsshallbefixedandreliableandhavebackupprotection.
7.7Ifdeterioratedorlowresistanceinsulatorsarefoundduringlivetestingofinsulators,theyshallberetested2-3
timestoavoidmisjudgment.
7.8Whenthefirstinsulatornearthecrossarmisdismantledorinstalled,itmustbeshort-circuitedbeforeoperation.
8Testoftools,devicesandequipment
8.1Thedesignofliveworkingtools,devicesandequipmentshallconformtotherequirementsofGB/T18037.
9
Conductiveclothing,insulatingropes,insulatingrods,insulatorholders,etc.,shallpasstypetestsandleaving
factorytestsinaccordancewiththerequirementsofGB/T6568,GB/T13035,GB13398,DL/T463,DL/T878.
8.2Thetools,devicesandequipmentshallbesubjectedtoelectricaltestsandmechanicaltestsonaregularbasis
accordingtothetestmethodsofDL/T976.Thetestcyclesareasfollows:
a)electricaltests.Preventivetestsshallbeconductedonceayear,andinspectiontestsshallbeconductedoncea
year,andtheintervalbetweentwotestsshallbehalfayear.
b)mechanicaltests.Preventivetestsshallbeconductedonceeverytwoyearsforinsulatingtoolsandonceevery
yearformetaltools.
8.3Preventivetests
8.3.1DCwithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe4.8m;
thewithstandvoltageshallbe755kV;thetimesh
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 專利權(quán)質(zhì)押合同范例
- 企業(yè)用人訂單合同范例
- 個(gè)人購(gòu)銷合同范例藥材
- 會(huì)展設(shè)備采購(gòu)合同范例
- 臨建空調(diào)采購(gòu)合同范例
- 2025年光學(xué)纖維倒像器合作協(xié)議書(shū)
- 2025年HB步進(jìn)電機(jī)合作協(xié)議書(shū)
- 2023-2024學(xué)年安徽省江淮名校高一下學(xué)期開(kāi)學(xué)聯(lián)考英語(yǔ)試題(解析版)
- 2025年醋酸乙酯合作協(xié)議書(shū)
- 檔案代管合同
- 2024年全國(guó)公共營(yíng)養(yǎng)師之三級(jí)營(yíng)養(yǎng)師考試重點(diǎn)試題(附答案)
- 管道工(三級(jí))高級(jí)工題庫(kù)(電子題庫(kù))附有答案
- 小學(xué)預(yù)防性侵害主題班會(huì)
- DZ∕T 0080-2010 煤炭地球物理測(cè)井規(guī)范(正式版)
- 《微波法原油含水率在線檢測(cè)儀》
- 第1課 立足時(shí)代 志存高遠(yuǎn) (課件+視頻)- 【中職專用】高一思想政治《心理健康與職業(yè)生涯》(高教版2023·基礎(chǔ)模塊)
- 19S406建筑排水管道安裝-塑料管道
- MOOC 人工智能基礎(chǔ)-國(guó)防科技大學(xué) 中國(guó)大學(xué)慕課答案
- 裝配式建筑預(yù)制構(gòu)件安裝-水平構(gòu)件安裝技術(shù)
- 部編版語(yǔ)文五年級(jí)下冊(cè)第四單元大單元整體教學(xué)設(shè)計(jì)
- 《廂式貨運(yùn)車(chē)系列型譜》
評(píng)論
0/150
提交評(píng)論