




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
——Createbetterlifebyhightech國際市場部高帥introducing
NewERP&EnergyLabelHISTORYOFERP2005年歐盟公布了《制定能耗產(chǎn)品的生態(tài)設(shè)計(jì)要求框架指令》2009年10月31號(hào),歐盟發(fā)布了《能源相關(guān)產(chǎn)品的設(shè)計(jì)要求框架》2009年3月18號(hào)發(fā)布?xì)W盟委員會(huì)NO244/2009號(hào)條例《歐盟議會(huì)與歐盟委員會(huì)第2005/321/EC號(hào)指令關(guān)于非定向燈的生態(tài)設(shè)計(jì)指令要求之實(shí)施細(xì)那么》2012年12月14號(hào)發(fā)布?xì)W盟委員會(huì)NO1194/2012號(hào)條例《歐盟議會(huì)與歐盟委員會(huì)第2009/125/EC號(hào)指令關(guān)于定向燈、LED燈、相關(guān)設(shè)備的生態(tài)設(shè)計(jì)指令要求之實(shí)施細(xì)那么》至此,對LED燈形成了完整的限制性生態(tài)設(shè)計(jì)要求It’snotjustabouttheproducts,butthewholeworldCONTENTCOMMISSIONREGULATION(EU)No1194/2012COMMISSIONDELEGATEDREGULATION(EU)No874/2012implementingDirective2009/125/ECoftheEuropeanParliamentandoftheCouncilwithregardtoecodesignrequirementsfordirectionallamps,lightemittingdiodelampsandrelatedequipmentsupplementingDirective2010/30/EUoftheEuropeanParliamentandoftheCouncilwithregardtoenergylabellingofelectricallampsandluminaires重點(diǎn)講解內(nèi)容COMMISSIONREGULATION(EU)No1194/2012Scopedirectionallampslight-emittingdiode(LED)lampsequipmentdesignedforinstallationbetweenthemainsandthelamps,includinglampcontrolgear,controldevicesandluminaires(otherthanballastsandluminairesforfluorescentandhigh-intensitydischargelamps)includingwhentheyareintegratedintootherproducts‘lampcontrolgear’
meansadevicelocatedbetweentheelectricalsupplyandoneormorelamps,whichprovidesafunctionalityrelatedtotheoperationofthelamp(s),suchastransformingthesupplyvoltage,limitingthecurrentofthelamp(s)totherequiredvalue,providingstartingvoltageandpreheatingcurrent,preventingcoldstarting,correctingthepowerfactororreducingradiointerference.Thedevicemaybedesignedtoconnecttootherlampcontrolgeartoperformthesefunctions.Thetermdoesnotinclude:—controldevices—powersupplieswithinthescopeofCommissionRegu-lation(EC)No278/2009‘controldevice’
meansanelectronicormechanicaldevicecontrollingormonitoringtheluminousfluxofthelampbyothermeansthanpowerconversion,suchastimerswitches,occupancysensors,lightsensorsanddaylightregulationdevices.Inaddition,phasecutdimmersshallalsobeconsideredascontroldevices;DEFINATIONOFCONTROLGEARANDCONTRONDEVICECOMMISSIONREGULATION(EU)No1194/2012StagesCOMMISSIONREGULATION(EU)No1194/2012EnergyefficiencyEEI=Prated*K/Pref
requirementsfordirectionallampsEnergyEfficiencyIndexRatedPowerCorrectionFactorsReferencePowerCOMMISSIONREGULATION(EU)No1194/2012CorrectionFactorsK=COMMISSIONREGULATION(EU)No1194/2012ReferencePower(Pref)FormodelswithΦuse<1300lumen
Pref=0.88√Φuse+0.049ΦuseFormodelswithΦuse≥1300lumen
Pref=0.07341ΦuseDefinitionofΦuse:directionallampswithabeamangle≥90°otherthanfilamentlamps:ratedluminousfluxina120°cone(Φ120°)otherdirectionallamps:ratedluminousfluxina90°cone(Φ90°)COMMISSIONREGULATION(EU)No1194/2012EnergyefficiencyRequirementsfordirectionallampsCOMMISSIONREGULATION(EU)No1194/2012EnergyefficiencyRequirementsforlampcontrolgearStage2no-loadpowerofalampcontrolgearshallnotexceed1,0Wtheefficiencyofahalogenlampcontrolgearshallbeatleast0,91at100%load.Stage3no-loadpowerofalampcontrolgearshallnotexceed0.5WForlampcontrolgearwithoutputpower(P)over250W,theno-loadpowerlimitsshallbemultipliedbyP/250W.COMMISSIONREGULATION(EU)No1194/2012Functionalityrequirements FordirectionalCFLCOMMISSIONREGULATION(EU)No1194/2012Functionalityrequirements
Forotherdirectionallamps(excludingLEDlamps,compactfluorescentlampsandhigh- intensitydischargelamps)EnergyLabellingofElectricalLampsandLuminaires
COMMISSIONDELEGATEDREGULATION(EU)No874/2012COMMISSIONREGULATION(EU)No1194/2012Functionalityrequirements Fornon-directionalanddirectionalLEDlampsProductinformationrequirementsfordirectionallamps1.Informationtobedisplayedonthelampitself
Forlampsotherthanhigh-intensitydischargelamps,thevalueandunit(‘lm’,‘K’and‘°’)ofthenominalusefulluminousflux,ofthecolourtemperatureandofthenominalbeamangleshallbedisplayedinalegiblefontonthesurfaceofthelampif,aftertheinclusionofsafety-relatedinformationsuchaspowerandvoltage,thereissufficientspaceavailableforitonthelampwithoutundulyobstructingthelightcomingfromthelamp.Ifthereisroomforonlyoneofthethreevalues,thenominalusefulluminousfluxshallbeprovided.Ifthereisroomfortwovalues,thenominalusefulluminousfluxandthecolourtemperatureshallbeprovided.1.nominalusefulluminousflux2.thenominalusefulluminousfluxandthecolourtemperature2.Informationtobevisiblydisplayedtoend-users,priortotheirpurchase,onthepackagingandonfreeaccesswebsitesTheinformationinparagraphs(a)to(o)belowshallbedisplayedonfreeaccesswebsitesandinanyotherformthemanufacturerdeemsappropriate.Iftheproductisplacedonthemarketinapackagingcontaininginformationtobevisiblydisplayedtotheend-users,priortotheirpurchase,theinformationshallalsobeclearlyandprominentlyindicatedonthepackaging.Theinformationdoesnotneedtousetheexactwordingonthelistbelow.Itmaybedisplayedintheformofgraphs,drawingsorsymbolsratherthantext.(a)Nominalusefulluminousfluxdisplayedinafontatleasttwiceaslargeasanydisplayofthenominallamppower;(b)Nominallifetimeofthelampinhours(notlongerthantheratedlifetime);(c)Colourtemperature,asavalueinKelvinsandalsoexpressedgraphicallyorinwords;(d)Numberofswitchingcyclesbeforeprematurefailure;(e)Warm-uptimeupto60%ofthefulllightoutput(maybeindicatedas‘instantfulllight’iflessthan1second);(f)Awarningifthelampcannotbedimmedorcanbedimmedonlyonspecificdimmers;inthelattercasealistofcompatibledimmersshallbealsoprovidedonthemanufacturer'swebsite;(g)Ifdesignedforoptimumuseinnon-standardconditions(suchasambienttemperatureTa≠25°Corspecificthermalmanagementisnecessary),informationonthoseconditions;(h)Lampdimensionsinmillimetres(lengthandlargestdiameter);(i)Nominalbeamangleindegrees;(j)Ifthelamp’sbeamangleis≥90°anditsusefulluminousfluxasdefinedinpoint1.1ofthisAnnexistobemeasuredina120°cone,awarningthatthelampisnotsuitableforaccentlighting;(k)Ifthelampcapisastandardisedtypealsousedwithfilamentlamps,butthelamp’sdimensionsaredifferentfromthedimensionsofthefilamentlamp(s)thatthelampismeanttoreplace,adrawingcomparingthelamp’sdimensionstothedimensionsofthefilamentlamp(s)itreplaces;Productinformationrequirementsfordirectionallamps(l)Anindication
thatthelampisofatypelistedinthefirstcolumnofTable6maybedisplayedonlyiftheluminousfluxofthelampina90°cone(Φ90°)isnotlowerthanthereferenceluminousfluxindicatedinTable6forthesmallestwattageamongthelampsofthetypeconcerned.Thereferenceluminousfluxshallbe
multipliedby
thecorrectionfactorinTable7.ForLEDlamps,itshallbeinadditionmultipliedbythecorrectionfactorinTable8;(m)Anequivalenceclaiminvolvingthepowerofareplacedlamptypemaybe
displayedonlyifthelamptypeislistedinTable6andiftheluminousfluxofthelampina90°cone(Φ90°)isnotlowerthanthecorrespondingreferenceluminousfluxinTable6.ThereferenceluminousfluxshallbemultipliedbythecorrectionfactorinTable7.ForLEDlamps,itshallbeinadditionmultipliedbythecorrectionfactorinTable8.Theintermediatevaluesofboththeluminousfluxandtheclaimedequivalentlamppower(roundedtothenearest1W)shallbecalculatedbylinearinterpolationbetweenthetwoadjacentvalues.計(jì)算公式:GU10Y=AX+M(104<x<144;144<x<230;230<x<345)equivalenceclaimforMR16equivalenceclaimforGU10MULTIPLICATIONFACTORS
EquivalenceClaimEquivalenceW=〔referencecone90°〕*K1*K2*K3
Verificationprocedureformarketsurveillancepurposes
Verificationprocedureformarketsurveillancepurposes
Verificationprocedureformarketsurveillancepurposes
VerificationprocedureformarketsurveillancepurposesCOMMISSIONDELEGATEDREGULATION(EU)No874/2012Scopefilamentlampsfluorescentlampshigh-intensitydischargelampsLEDlampsandLEDmodulesLuminairesdesignedtooperatesuchlampsandmarketedtoendusersExcludedProductslampsandLEDmoduleswithaluminousfluxoflessthan30lumenslampsandLEDmodulesmarketedforoperationwithbatteriesprimarypurposeisnotlightingdonotcomplywithrequirementsofDirective2009/125/ECDirective98/11/ECsh
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 設(shè)計(jì)師職業(yè)發(fā)展路徑指南
- 2025屆內(nèi)蒙古呼倫貝爾市阿榮旗第五區(qū)域聯(lián)合體三年級數(shù)學(xué)第一學(xué)期期末統(tǒng)考試題含解析
- 設(shè)計(jì)師感簡歷設(shè)計(jì)要點(diǎn)
- 行政管理中的公共關(guān)系學(xué)組織治理模型及試題及答案
- 包裝設(shè)計(jì)年度總結(jié)
- 行政管理公共服務(wù)試題與答案
- 工程項(xiàng)目管理實(shí)施步驟試題及答案
- 二手房買賣咨詢服務(wù)協(xié)議
- 擔(dān)保書之擔(dān)保型買賣合同
- 酒店管理與服務(wù)實(shí)戰(zhàn)指南
- 幼兒園營養(yǎng)膳食蔬菜水果認(rèn)知主題課件
- 河北省五個(gè)一名校2025屆高考物理押題試卷含解析
- 開具保函委托協(xié)議書范本
- DL∕T 860.4-2018 電力自動(dòng)化通信網(wǎng)絡(luò)和系統(tǒng) 第4部分:系統(tǒng)和項(xiàng)目管理
- 建筑工程總價(jià)包干合同
- 2024年高考數(shù)學(xué)答題技巧與模板 不等式相關(guān)解題技巧(基本不等式鏈、權(quán)方和不等式、兩類糖水不等式)(解析版)
- 信息技術(shù)與人工智能智慧樹知到期末考試答案章節(jié)答案2024年重慶工業(yè)職業(yè)技術(shù)學(xué)院
- 第六章-數(shù)據(jù)采集技術(shù)課件
- 《人像攝影教程》課件
- 復(fù)綠施工方案
- 2024年貴州黔東南州能源投資有限公司招聘筆試參考題庫含答案解析
評論
0/150
提交評論