1、Network Automation Engine Catalog PageMS-NAE35, MS-NAE45, MS-NAE55, NAE8500-0Code No. LIT-1900195Software Release 6.5Issued February 14, 2014Supersedes June 17, 2013Refer to the QuickLIT website for the most up-to-date version of this document.Network Automation Engines (NAEs) provide compensive equ
2、ipment monitoring and control, through key features such as scheduling, alarm and event management, energy management, data exchange, data trending, and data storage. These tools help reduce operation and energy costs for any type of building.This line of NAEs features and leverages IP connectivity
3、and web-based access to Metasys® Building Management Systems, including the BACnet® protocol, the LONWORKS® network, and the N2 Bus protocol, to monitor and supervise a wide variety of HVAC, lighting, security, and fire safety equipment.With the embedded Site Management Portal user in
4、terface, NAEs can support multiple concurrent web browser sessions with password and permission access control. To further enhance IT compatibility, NAEs employ standard IT security best practices.NAEs have an embedded UI and the capability to connect to and communicate with cloud-based applications
5、. NAEs support concurrently connected web browsers.Site Director FunctionSite Management Portal System Configuration Software Embedded in NAEUser Interface and Online System Configuration Software Embedded in NAESupervision of Field Controller Networks Including BACnet MS/TP, N2 Bus LONWORKS Network
6、, and BACnet IP DevicesMultiple Connection Options for Data AccessFigure 1: NAE55 Network Automation EngineSpecific features of NAE ms include the following:NAE55 ms support a compensive set of supervisory featuresand functions for large and technically advanced buildings and controllers.NAE35/NAE45
7、 ms enable cost-effective NAE connectivity andcontrol in smaller facilities and can increase distribution of control in larger facilities.The NAE85 is a high-capacity NAE that is designed to provide supervisory level control of Metasys networks that include a large number of BACnet IP devices.Refer
8、to the Network Automation Engine (NAE) Product Bulletin (LIT-1201160) for important product application information.FeaturesRepair InformationIf the NAE fails to operate within its specifications, replace the unit. For a replacement NAE, contact the nearest Johnson Controls® representative.Comm
9、unication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise LevelWeb-Based User InterfaceOrdering InformationContact the nearest Johnson Controls representative to order an NAE. Specify the desired product code from Table 1 for the NAE35, Table 2for the N
10、AE45, Table 3 for the NAE55, Table 4 for the NAE85, and Table 5 for accessories.Table 1: NAE35 Ordering InformationNetwork Automation Engine Catalog Page1Product Code Number1DescriptionMS-NAE35(BaseNAE35 Network Automation Engines: Requires a 24 VAC power supply. Each mincludes one RS-232-C serial p
11、ort, one USBFeatures of Each NAE35)serial port, one Ethernet port, and an MS-BAT1020-0 DataBattery.MS-NAE3510-2Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports aum of 50 devices on the N2 Bus or BACnet MS/TP trunk.M
12、S-NAE3510-2USupports one BACnet MS/TP (RS-485) trunk; includes an addi ional RS-232-C serial port for optional external modem; supports aum of 50 devices on the BACnet MS/TP trunk.Note:This mis UL Listed, File S4977, UUKL 864 - 9th Edition Smoke Control Equipment. Also, in order to be UL/ULC complia
13、nt, this mmust be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory.MS-NAE3511-2Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports aum of 50 devices on the N2 Bus or BACnet MS/TP trunk.MS-NAE3514-2Supports on
14、e N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an additional RS-232-C serial port for optional external modem; supports aum of 50 devices on the N2 Bus or BACnet MS/TP trunk.Table 1: NAE35 Ordering Information1Some ms are also available in Buy American version (ad
15、d G after the code number). For repair parts, add -702 after the code number.Table 2: NAE45 Ordering Information1Some ms are also available in Buy American version (add G after the code number). For repair parts, add -702 after the code number.Table 3: NAE55 Ordering Information1Some ms are also ava
16、ilable in Buy American version (add G after the code number). For the European versions of the NAE55, add an E after the codenumber. For repair parts, add -702 after the code number.Network Automation Engine Catalog Page2Product Code Number1DescriptionMS-NAE55(BaseNAE55 Network Automation Engines: R
17、equires a 24 VAC power supply. Each mincludes two RS-232-C serial ports, two USBFeatures of Each NAE55)serial ports, two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 DataBattery.MS-NAE5510-2Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP tru
18、nk); supports a um of 100 devices on each N2 Bus or BACnet MS/TP trunk.MS-NAE5510-2USupports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); supports a um of 100 devices on each N2 Bus or BACnet MS/TP trunk.Note:This mis UL Listed, File S4977, UUKL 86
19、4 - 9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this mmust be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory.MS-NAE5511-2Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACne
20、t MS/TP trunk); supports a um of 100 devices on each N2 Bus or BACnet MS/TP trunk; includes an internal modem.MS-NAE5520-2Supports a LONWORKS trunk, and two N2 Bus trunks or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk). Supports aum of 255 devices on the LONWORKS
21、 trunk and aum of 100 devices on each N2 Bus or BACnet MS/TP trunk.MS-NAE5521-2Supports a LONWORKS trunk, and two N2 Bus trunks or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); includes an internal modem. Supports aum of 255 devices on the LONWORKS trunk and aum
22、of 100 devices on each N2 Bus or BACnet MS/TP trunk.Product Code Number1DescriptionMS-NAE45(BaseFeatures of Each NAE45)NAE45 Network Automation Engines: Requires a 24 VAC power supply. Each mincludes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 DataBattery.MS
23、-NAE4510-2Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports aum of 100 devices on the N2 Bus or BACnet MS/TP trunk.MS-NAE4510-2USupports one BACnet MS/TP (RS-485) trunk; includes an addi ional RS-232-C serial port fo
24、r optional external modem; supports aum of 100 devices on the BACnet MS/TP trunk.Note:This mis UL Listed, File S4977, UUKL 864 - 9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this mmust be pre-installed and pre-wired in a standard or custom panel built in the Johnson Co
25、ntrols Reynosa factory.MS-NAE4511-2Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports aum of 100 devices on the N2 Bus or BACnet MS/TP trunk.MS-NAE4520-2Supports one LONWORKS trunk, includes an addi ional RS-232-C serial port for optional external modem; support
26、s aum of 127 devices on the LONWORKS port.MS-NAE4521-2Supports one LONWORKS trunk, includes an internal modem; supports aum of 127 devices on the LONWORKS port.Product Code Number1DescriptionMS-NAE3515-2Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an
27、internal modem; supports a um of 50 devices on the N2 Bus or BACnet MS/TP trunk.MS-NAE3520-2Supports one LONWORKS trunk; includes an addi ional RS-232-C serial port for optional external modem. Supports aum of 64 devices on the LONWORKS port.MS-NAE3521-2Supports one LONWORKS trunk; includes an inter
28、nal modem. Supports aum of 64 devices on the LONWORKS port.MS-NAE3524-2Supports one LONWORKS trunk; limited to Basic Access support; and includes an additional RS-232-C serial port for optional external modem. Supports aum of 64 devices on the LONWORKS trunks.MS-NAE3525-2Supports one LONWORKS trunk;
29、 limited to Basic Access support; and includes an internal modem. Supports aum of 64 devices on the LONWORKS trunks.Table 4: NAE85 Ordering Information1Standard NxE85 ms support 10,000 objects; an expansion upgrade is available to support an additional 15,000 objects.Table 5: NAE Accessories Orderin
30、g InformationTechnical SpecificationsTable 6: NAE35 and NAE45Network Automation Engine Catalog Page3Power RequirementDedicated nominal 24 VAC, Class 2 power supply (North America), safety extra-low voltage (SELV) power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VACum)Power Consumption25 VAum
31、Ambient Operating Conditions0 to 50°C (32122°F); 10 to 90% RH, 30°C (86°F)um dew pointAmbient Storage Conditions-40 to 70°C (-40 to 158°F); 5 to 95% RH, 30°C (86°F)um dew pointDataBatterySupports dataon power failure. Rechargeable NiMH battery: 3.6 VDC 500 mAh
32、, with a typical life of 5 to 7 years at 21°C (70°F); Product Code Number: MS-BAT1020-0Processor192 MHz Renesas® SH4 7760 RISC processorMemory128 MB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup128 MB synchronous dynamic rand
33、om access memory (SDRAM) for operations data dynamic memoryOperating SystemMicrosoft® Windows® Embedded CE 6.0Network and Serial InterfacesOne Ethernet port; connects at 10 or 100 Mbps; 8-pin RJ-45 connectorOne optically isolated RS-485 port; 9.6k, 19.2k, 38.4k, or 76.8k baud (depending on
34、 protocol); with a pluggable and keyed 4-position terminal block (FC Bus available on NAE351x and NAE451x ms only)One LONWORKS port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE352x-x and NAE452x ms only)One RS-232-C serial port with standard 9-pin sub-D
35、connector that supports standard baud rates.A second serial port, on ms without an internal modem, that supports an optional, user-d external modem. One USB serial port with standard USB connector that supports an optional, user-d external modem.Option: One telephone port for internal modem; up to 5
36、6 Kbps; 6-pin modular connector (NAE ms with an optional internal modem have one RS-232-C serial port only.)HousingPlastic housing material: ABS polycarbonateUL94-5VB: IP20 (IEC 60529)Product Code NumberDescriptionMS-BAT1010-0Replacement databattery for NAE55 and NIE55. Rechargeable gel cell battery
37、: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21°C (70°F)MS-BAT1020-0Replacement databattery for NAE35, NAE45, and NCE25. Rechargeable NiMH battery: 3.6 V 500 mAh, with a typical life of 5 to 7 years at 21°C (70°F)MS-15KUPG-015,000 object expansion upgrade for NxE85 (onl
38、y one expansion per NxE85)MS-MULTENGSW-6Contains ToggleTunnel utility for converting an NAE55/NIE55 to an NAE55 mwith the N2 Tunneling features enabled. Not for use with MS-NAE5510-1U.MS-RAP-0y Access Portal Server provides a user interface that is a natural, complementary extension of the Metasys S
39、ite Management Portal user interface.Note:This option is not necessary for sites that have an ADS/ADX that is the Site Director becausey Access Portal Server is provided with the ADS/ADX solution.MS-EXPORT-0Export Utility extracts historical trend, alarm, and audit data from the system and presents
40、the historical data in a variety of formats.Note:This option is not necessary for sites that have an ADS/ADX that is the Site Director because Export Utility is provided with the ADS/ADX solution.AS-XFR100-1Power transformer (Class 2, 24 VAC, 92 VAum output), with enclosureAS-XFR010-1Power transform
41、er (Class 2, 24 VAC, 92 VAum output), no enclosureSC450RM1U (OEM Part No.)Recommended UPS for NxE85 m: APC® Smart-UPS SC 450 VA, 280 W, 120 VAC input/output with NEMA 5-15R output connectionsProduct Code NumberDescriptionMS-NIE8500-0Rack-mount server preloaded with supported operating system, N
42、xE85 software, and other Metasys system software components; supports up to 10,000 objects.Note:The NAE85 ms ship as MS-NIE8500-0 ms. Use the Change Mutility in the NxE85 Metasys software to change an NIE85 to an NAE85.MS-NxE85SW-01New NxE85 software only; for new installations/projectsMS-NxE85SW-61
43、Upgrade NxE85 software; for existing NxE85 enginesTable 6: NAE35 and NAE45Table 7: NAE55xx-2Table 8: NAE85 TurnkeyNetwork Automation Engine Catalog Page4Computer TypeDell® PowerEdge® R420 or latest equivalentPower Requirement120240 VAC 50/60 HzPower Supply480 WAmbient Operating Conditions1
44、0 to 35°C (50 to 95°F); 20 to 80% RH (noncondensing twmax = 29°C)Power RequirementDedicated nominal 24 VAC, Class 2 power supply (North America),SELV power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VACum)Power Consumption50 VAumAmbient Operating Conditions0 to 50°C (32 t
45、o 122°F); 10 to 90% RH, 30°C (86°F)um dew pointAmbient Storage Conditions-40 to 70°C (-40 to 158°F); 5 to 95% RH, 30°C (86°F)um dew pointDataBatterySupports dataon power failure. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21
46、°C (70°F); Product Code Number: MS-BAT1010-0Clock BatteryMaintains real-time clock through a power failure. Onboard cell; typical life 10 years at 21°C (70°F)Processor1.6 GHz Intel® Atom processorMemory4 GB (2 GB partitioned) flash nonvolatile memory for operating system, co
47、nfiguration data, and operations data storage and backup1 GB SDRAM for operations data dynamic memory for all msOperating SystemMicrosoft Windows Embedded Standard 2009Network and Serial InterfacesOne Ethernet port; connects at 10 Mbps, 100 Mbps, or 1 Gbps; 8-pin RJ-45 connectorTwo optically isolate
48、d RS-485 ports; 9.6k, 19.2k, 38.4k, or 76.8k baud; pluggable and keyed 4 position terminal blocks (RS-485 ports available on NAE55 ms only)Two RS-232-C serial ports, with standard 9-pin sub-D connectors, that support all standard baud rates Two USB serial ports; standard USB connectors support an op
49、tional, user-d external modem Options: One telephone port for internal modem; up to 56 kbps; 6-pin modular connectorOne LONWORKS port; FTT10 78 kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE552x-x ms only)HousingPlastic housing with internal metal shieldPlastic mate
50、rial: ABS + polycarbonate UL94-5VB: IP20 (IEC 60529)MountingOn flat surface with screws on four mounting feet or on dual 35 mm DIN railDimensions (Height x Width x Depth)226 x 332 x 96.5 mm (8-7/8 x 13-1/8 x 3-13/16 in ) including mounting feetMinimum space for mounting: 303 x 408 x 148 mm (12 x 16-
51、1/8 x 5-13/16 in.)ShipWeight2.9 kg (6.4 lb)ComplianceUnited States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, FCC Compliant to CFR47, Part 15, Subpart B, Class ACanada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment, Industry Canada Complian
52、t, ICES-003Europe: CE Mark Johnson Controls, Inc., declares hat this product is in compliance wi h the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC.Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions CompliantBACnet International: BTL 135-2004 List
53、ed B-BCMountingOn flat surface with screws on hree mounting clips or a single 35 mm DIN railDimensions (Height x Width x Depth)131 x 270 x 62 mm (5-3/16 x 10-5/8 x 2-1/2 in.)Minimum space for mounting NAE35 and NAE45: 210 x 350 x 110 mm (8-3/16 x 13-13/16 x 4.-5/16 in.)ShipWeight1.2 kg (2.7 lb)Compl
54、ianceUnited States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, UL Listed, FIle S4977, UUKL 864- 9th Edition, Smoke Control Equipment(MS-NAE35x0-2U and MS-NAE45x0-2U ms only) FCC Compliant to CFR47, Part 15, Subpart B, Class ACanada: UL Listed, File E107041, CCN PAZX7, CA
55、N/CSA C22.2 No. 205, Signal Equipment; Industry Canada Compliant, ICES-003Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions CompliantEurope: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EM
56、C Directive 2004/108/EC.BACnet International: BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Building Controller (B-BC)Table 8: NAE85 TurnkeyTable 9: NAE85 Software System Requirements for Installation/UpgradeNetwork Automation Engine Catalog Page5Product CodeMS-NxE85SW-0: NxE85 software f
57、or 10,000 objects (new projects only software)Recommended Computer PlatformIntel Xeon®E5506, 2.13 GHz, 4 MB Cache 2 x 160 GB 7.2K , 8.9 cm (3.5 in.) Cabled3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS Controller)DVD ROM, SATAMemory2 GB RAM minimumHard Disk160 GB minimumSupported Op
58、erating Systems and SoftwareWindows Server® 2012 R2 Standard and Enterprise Editions Microsoft .NET Framework Version 3.5 Service Pack (SP) 1 Windows Server® 2012 Standard and Enterprise Editions Microsoft .NET Framework Version 3.5 SP1Windows Server 2008 R2 Standard and Enterprise Editions with SP1Microsoft .NET Framework Version 3.5 SP1 Windows Server 200
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 北京汽車托運(yùn)合同范本
- 2025年泰州貨運(yùn)從業(yè)資格證怎么考
- 修復(fù)車交易合同范本
- 醫(yī)院弱電集成合同范本
- 制衣廠勞動(dòng)合同范本
- 主廚合同范本
- 與中介定金合同范本
- 棉花勞務(wù)合同范本
- 冠名使用合同范本
- 勞動(dòng)合同范本完整
- 2024年新人教版化學(xué)九年級(jí)上冊(cè)全冊(cè)課件(新版教材)
- 智能體脂秤市場(chǎng)洞察報(bào)告
- 教科版 二年級(jí)科學(xué)上冊(cè)第一單元第6課《不同的季節(jié)》同步練習(xí)(附答案解析)
- 山東省東營(yíng)市2024年中考英語(yǔ)真題【附真題答案】
- 2024義務(wù)教育英語(yǔ)新課標(biāo)課程標(biāo)準(zhǔn)2022年版考試真題附答案
- 粵港澳宜居城市建設(shè)協(xié)同發(fā)展策略
- GB/T 12279.2-2024心血管植入器械人工心臟瓣膜第2部分:外科植入式人工心臟瓣膜
- 動(dòng)物防疫服務(wù)投標(biāo)方案(技術(shù)方案)
- 2024年新課標(biāo)全國(guó)Ⅰ卷語(yǔ)文高考真題試卷(含答案)
- 2022-2023學(xué)年廣州市六年級(jí)下學(xué)期數(shù)學(xué)期末考試試卷及答案解析
- JTG-3830-2018公路工程建設(shè)項(xiàng)目概算預(yù)算編制辦法
評(píng)論
0/150
提交評(píng)論