臨水臨電方案全解_第1頁
臨水臨電方案全解_第2頁
臨水臨電方案全解_第3頁
臨水臨電方案全解_第4頁
臨水臨電方案全解_第5頁
已閱讀5頁,還剩20頁未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

精選優(yōu)質(zhì)文檔-----傾情為你奉上/r/n精選優(yōu)質(zhì)文檔-----傾情為你奉上/r/n專心---專注---專業(yè)/r/n專心---專注---專業(yè)/r/n精選優(yōu)質(zhì)文檔-----傾情為你奉上/r/n專心---專注---專業(yè)/r/n目錄/r/n臨時(shí)用電方案/r/n一、工程概況/r/n編制依據(jù)和組織設(shè)計(jì)范圍/r/n1.1按照中國建筑工業(yè)出版社《施工現(xiàn)場臨時(shí)用電安全技術(shù)規(guī)范》JGJ46/r/n——/r/n2005的規(guī)定:/r/n“/r/n臨時(shí)用電設(shè)備在5臺(tái)及5臺(tái)以上或設(shè)備總?cè)萘吭?0KW及50KW以上者,應(yīng)編制臨時(shí)用電施工組織設(shè)計(jì)。/r/n”/r/n1.2臨時(shí)用電所涉及的主要國家或行業(yè)規(guī)范/r/n﹑/r/n標(biāo)準(zhǔn)/r/n﹑/r/n法規(guī);建筑工地的有關(guān)圖紙,相關(guān)資料和《建筑工地用電規(guī)范》(JGJ16-84)/r/n﹑/r/n《供電管理?xiàng)l理》/r/n﹑/r/n《建筑施工安全檢查標(biāo)準(zhǔn)》(JGJ59-/r/n2011/r/n)等]。/r/n1/r/n、《施工現(xiàn)場臨時(shí)用電安全技術(shù)規(guī)范》—JGJ46-/r/n2005;2/r/n、《低壓配電設(shè)計(jì)規(guī)范》—GB50054-95/r/n;3/r/n、《供配電系統(tǒng)設(shè)計(jì)規(guī)范》—GB50052-95/r/n;4/r/n、《通用用電設(shè)備配電設(shè)計(jì)規(guī)范》—GB50055/r/n-/r/n93/r/n。/r/n1.3制定安全用電技術(shù)措施/r/n﹑/r/n電氣防火措施/r/n﹑/r/n人員配制及相關(guān)資料圖表。/r/n2./r/n工程涉電類概況/r/n2.1/r/n貴州三力制藥新版/r/nGMP異地改造/r/n工程位于/r/n貴州省安順市平壩縣夏云鎮(zhèn)/r/n。本工程是針對場地內(nèi)的/r/n制劑車間、提取車間、鍋爐房、成品包裝車間、辦公樓、食堂、宿舍樓、員工俱樂部、污水處理設(shè)施、管理用房、門衛(wèi)等單體建筑及圍墻、硬化地面、環(huán)境道路等工程/r/n的臨時(shí)用電編制的施工方案。本工程/r/n制劑車間、提取車間、成品包裝車間、食堂、員工俱樂部為一層鋼結(jié)構(gòu)建筑;鍋爐房為一層框架結(jié)構(gòu)建筑;辦公樓為/r/n5+1框架結(jié)構(gòu),檐高20米;宿舍樓為四層混合結(jié)構(gòu)。/r/n合計(jì)建筑面積為/r/n51852/r/n平方米。/r/n建設(shè)單位:/r/n貴州三力制藥有限公司/r/n設(shè)計(jì)單位:/r/n上海大同一鋼/r/n建筑設(shè)計(jì)研究院/r/n有限公司/r/n監(jiān)理單位:/r/n四川四強(qiáng)建設(shè)項(xiàng)目管理有限/r/n公司/r/n施工單位:/r/n貴州建工集團(tuán)第一建筑工程有限責(zé)任公司/r/n2.2/r/n安全目標(biāo):一般安全事故控制在1%以內(nèi),傷亡事故為6/r/n‰/r/n。/r/n臨時(shí)用電區(qū)別于/r/n“/r/n永久性/r/n”/r/n用電工程,是為專門的建筑施工需要提供電力的電氣工程。根據(jù)現(xiàn)場勘測,/r/n業(yè)主擬提供一臺(tái)/r/n315KVA和一臺(tái)800KVA/r/n變壓器,/r/n根據(jù)施工現(xiàn)場負(fù)荷計(jì)算,需開通/r/n800KVA變壓器供電,業(yè)主提供/r/n1個(gè)/r/n1000/r/nA駁接口,我司/r/n以B/r/nL/r/nVV-4*/r/n240/r/n+1*/r/n120/r/n電/r/n線/r/n2/r/n0/r/n米用電桿架空引至配電室,在總配電柜處做一組重復(fù)接地,施工現(xiàn)場采用TN-S三相五線制接零保護(hù)系統(tǒng)供電方式供電。/r/n現(xiàn)場的供電線路沿工程的/r/n制劑車間、提取車間、成品包裝車間、辦公樓、宿舍樓/r/n布置/r/n一/r/n條回路,其詳細(xì)布置請參見用電平面布置圖、供電系統(tǒng)圖。/r/n本方面方案設(shè)計(jì)說明如下:/r/n按供電可靠性的要求/r/n,/r/n本現(xiàn)場施工用電定為二級負(fù)荷/r/n,/r/n采用一個(gè)獨(dú)立的電源供電。/r/n現(xiàn)場施工用電的設(shè)備較多/r/n,/r/n設(shè)備之間的容量相差懸殊/r/n,/r/n為簡化計(jì)算/r/n,/r/n按需用系數(shù)法計(jì)算/r/n,/r/n需用系數(shù)是估計(jì)值。/r/n通過正確計(jì)算/r/n,/r/n合理分布負(fù)荷/r/n,/r/n使三相均衡。/r/n根據(jù)供電負(fù)荷容量及分布情況/r/n,/r/n使變配電房盡量靠近負(fù)荷中心,合理進(jìn)行補(bǔ)償/r/n,/r/n提高功率因素。/r/n為保證電氣設(shè)備或系統(tǒng)正常運(yùn)行,確保人身安全/r/n/r/n,將正常情況下不帶電的設(shè)備金屬外殼,底座,配電箱及開關(guān)箱金屬殼體牢固接地,即保護(hù)接地,保護(hù)接地不僅要與供電系統(tǒng)中/r/nPE/r/n相連外還在施工現(xiàn)場配電房外或供電系統(tǒng)末端,置一重復(fù)接地裝置,接地體采用4/r/n0*/r/n4角鋼焊接而成,埋地2.5米,接地電阻不超過10/r/n/r/n(詳見接地系統(tǒng)示意圖1)。為了保證安全用電,確保變壓器不超負(fù)荷工作,需用電量大的機(jī)械如對焊機(jī)、鋼筋豎焊機(jī)應(yīng)錯(cuò)開使用。表中有些機(jī)械為備用。/r/n在計(jì)算用電量時(shí),首先要確定施工現(xiàn)場的用電情況,考慮到:/r/n全工地所使用的機(jī)械設(shè)備,其他電氣工具及照明用電量數(shù)量;/r/n施工總進(jìn)度計(jì)劃高峰階段,同時(shí)用電的機(jī)械設(shè)備最高數(shù)量;/r/n各種機(jī)械設(shè)備在工作的時(shí)差情況;/r/n總電量可按下式計(jì)算:/r/n用電設(shè)備的計(jì)算負(fù)荷;/r/n有功功率:P/r/njs/r/n=/r/nK/r/nx/r/nP/r/ne/r/n千瓦;/r/n配電干線的計(jì)算負(fù)荷:/r/n有功功率:P/r/njs/r/n=/r/nK/r/nΣ/r/np/r/nΣ/r/n(K/r/nx/r/nP)千瓦;/r/n式中:/r/nP/r/ne/r/n—/r/n用電設(shè)備的設(shè)備功率,千瓦;/r/nK/r/nd/r/n—/r/n需要系數(shù)(查表);/r/nCOS/r/nφ—/r/n用電設(shè)備的功率因數(shù)(在施工現(xiàn)場COS/r/nφ/r/n量值為0.75~0.78,一般為0.65~0.75);/r/nK/r/nΣ/r/np/r/n—/r/n有功系數(shù),分別為0.8~0.9。/r/n生活用電和照明用電量與動(dòng)力用電量相比要少得多,因此在計(jì)算用電量時(shí),可以在動(dòng)力用電量之外再加10%作為生活用電量和照明電量。/r/n根據(jù)施工場所特性,主導(dǎo)線全部采用/r/n鋁/r/n芯導(dǎo)線/r/n架空敷設(shè)/r/n。/r/n根據(jù)選擇導(dǎo)線和電纜截面的一般條件,按允許截流量選擇導(dǎo)線和電纜截面時(shí),應(yīng)滿足下式要求:/r/n/r/nI/r/ny/r/n≥/r/nI/r/njs/r/n式中:/r/nI/r/njs/r/n──/r/n線路計(jì)算電流,安;/r/n/r/nI/r/ny/r/n──/r/n導(dǎo)線和電纜按發(fā)熱條件的長期允許電流,其中,地面上敷設(shè)(明設(shè))為/r/nθ/r/ne/r/n=40/r/n°/r/n,土壤中直接埋設(shè)為/r/nθ/r/ne/r/n=30/r/n°/r/n,其他為/r/nθ/r/ne/r/n=55/r/n°/r/n。/r/n常用導(dǎo)線和電纜的允許截流量見《電工材料使用手冊》(水利電力出版社1988年出版)。/r/n根據(jù)施工現(xiàn)場臨時(shí)用電的特殊性,結(jié)合采用TN-S供電系統(tǒng)的要求(即:把工作零線N和專用保護(hù)線層在供電電源處嚴(yán)格分開的供電系統(tǒng)),選擇電器的類型和規(guī)格時(shí),考慮周圍環(huán)境特征,用電器的固定或移動(dòng)限制、電流種類,電壓大小,保護(hù)要求(過負(fù)荷短路,漏電和失壓保護(hù))。/r/n用電設(shè)備/r/n特征選擇/r/n—/r/n開啟式,保護(hù)式,封閉式,密閉式和防爆式。必須按照實(shí)際,所需電流,電壓值,根據(jù)產(chǎn)品目錄選擇適當(dāng)型式的電氣設(shè)備。/r/n根據(jù)保護(hù)條件:/r/n短路保護(hù);/r/n過負(fù)荷保護(hù);/r/n重復(fù)短時(shí)工作制電動(dòng)機(jī)一般采用熱繼電器,大容量和重要用電設(shè)備可用過電流繼電器,相序繼電器;/r/n漏電保護(hù)/r/n─/r/n未級開關(guān)箱內(nèi)的漏電保護(hù)器其額定漏電動(dòng)作電流應(yīng)不大于30mA,額定漏電動(dòng)作時(shí)間應(yīng)大于0.1s;/r/n安全電壓保護(hù)/r/n─/r/n在地下室,高溫,有導(dǎo)電灰尖或燈具離地面高度低于2.4m的照明場所,采用36V;在潮濕的場所或金屬容器內(nèi)工作的照明電源電壓不大于24V。/r/n熔斷器的選擇/r/n─/r/n應(yīng)滿足正常工作電流和起動(dòng)尖峰電流的兩個(gè)條件;確保熔斷器動(dòng)作可靠,其檢驗(yàn)滿足:/r/n式中:Idmin/r/n──/r/n被保護(hù)線段最小短路電流,安/r/nKt.r/r/n──/r/n熔斷器動(dòng)作系數(shù),一般取4,有爆炸危險(xiǎn)場所取5/r/n注意工地不同設(shè)備的性能,選擇起動(dòng)控制系統(tǒng)電器;注意大型設(shè)備的降壓起動(dòng)問題和調(diào)速電機(jī)的可控硅整流調(diào)速主回路電器原件。排水(污)泵、給水、消防的自動(dòng)控制保護(hù)。/r/n二、負(fù)荷設(shè)計(jì)/r/n建筑工地臨時(shí)供電的動(dòng)力機(jī)械用電情況(見下表)/r/n主要施工機(jī)械一覽表/r/n序號/r/n機(jī)具名稱/r/n規(guī)格/r/n數(shù)量(臺(tái))/r/n電機(jī)容量(kW)/r/n1/r/n物料提升機(jī)/r/nSS/r/nE-1/r/n60/r/n2/r/n15/r/n*/r/n2/r/n=30.0/r/n2/r/n閃光對焊機(jī)/r/nUNI-100/r/n1/r/n100.0*1=100KVA/r/n3/r/n鋼筋切斷機(jī)/r/nGW40/r/n2/r/n7.5*/r/n2/r/n=/r/n15/r/n4/r/n鋼筋彎曲機(jī)/r/nY100L-4/r/n2/r/n3.0*/r/n2/r/n=/r/n6/r/n.0/r/n5/r/n鋼筋調(diào)直機(jī)/r/nJJK-1.5/r/n2/r/n4.0*/r/n2/r/n=/r/n8/r/n.0/r/n6/r/n電焊機(jī)/r/nBX6-500/r/n2/r/n12.0*/r/n2/r/n=/r/n24/r/n.0/r/n7/r/n插入式振動(dòng)器/r/nHZ6-50/r/n5/r/n1.1*/r/n5/r/n=/r/n5/r/n./r/n5/r/n8/r/n木工圓盤鋸/r/nMJ225/r/n2/r/n4.0*/r/n2/r/n=/r/n8/r/n.0/r/n9/r/n平板振動(dòng)器/r/nPZ6-50/r/n1/r/n1.1*/r/n1/r/n=/r/n1.1/r/n10/r/n攪拌機(jī)/r/nJNY1000/r/n1/r/n10.0*/r/n1/r/n=/r/n1/r/n0.0/r/n1/r/n1/r/n潛污泵/r/nIS125-100-20/r/n2/r/n0/r/n2/r/n0.0*3=/r/n6/r/n0.0/r/n1/r/n2/r/n空壓機(jī)/r/n/r/nHTA-120/r/n10/r/n15/r/n.0*1/r/n0/r/n=/r/n150/r/n.0/r/n14/r/n生活區(qū)/r/n30.0/r/n合計(jì)/r/n4/r/n47.6/r/nKW/r/n1、主要機(jī)械用電及照明用電統(tǒng)計(jì):/r/n共計(jì)/r/n447.6KW/r/n。/r/n2、負(fù)荷計(jì)算:/r/n物料提升機(jī)/r/nK/r/nd/r/n=0./r/n35/r/n/r/ncos/r/nφ/r/n=/r/n0.75/r/nP/r/njs1/r/n=0./r/n60/r/n×/r/n(4/r/n×/r/n7.5)/r/n=/r/n18.00/r/nKW/r/nQ/r/njs1/r/n=/r/n18.00/r/n×/r/n0.75/r/n=/r/n13.50/r/nKV/r/nar/r/n /r/n攪拌機(jī)組:K/r/nd/r/n=0./r/n60/r/n/r/ncos/r/nφ/r/n=/r/n0.75/r/nP/r/njs2/r/n==0./r/n6/r/n×/r/n24.6/r/n=/r/n14.76/r/n/r/nKW/r/nQ/r/njs2/r/n=/r/n14.76/r/n×/r/n0.75/r/n=/r/n11.07/r/n/r/nKV/r/nar/r/n(3)鋼筋加工機(jī)械(彎曲機(jī)、調(diào)直機(jī)、切斷機(jī)、對焊機(jī))/r/nK/r/nd/r/n=0./r/n65/r/n/r/ncosφ/r/n=/r/n0.75/r/nP/r/njs4/r/n=0./r/n65/r/n×/r/n129/r/n=/r/n83.85/r/n/r/nKW/r/nQ/r/njs4/r/n=/r/n83.85/r/n×/r/n0.75/r/n=/r/n62.89/r/nKV/r/nar/r/n(4)電焊機(jī):K/r/nd/r/n=0./r/n35/r/n/r/ncosφ/r/n=/r/n0.80/r/nP/r/njs6/r/n=0.45×/r/n2/r/n×/r/n12.0/r/n=/r/n10.8/r/nKW/r/nQ/r/njs6/r/n=/r/n10.8/r/n×/r/n0.80/r/n=/r/n8.64/r/n/r/nKV/r/n水泵:K/r/nd/r/n=/r/n0.75/r/n/r/ncosφ/r/n=/r/n0.80/r/n/r/nP/r/njs9=0.75/r/n×/r/n60/r/n=/r/n45/r/nKW/r/nQ/r/njs9=0.80/r/n×/r/n45/r/n=/r/n36/r/n/r/nKv/r/nar/r/n(/r/n6)/r/n空壓機(jī):/r/nK/r/nd/r/n=/r/n0.75/r/n/r/ncosφ/r/n=/r/n0.80/r/n/r/n/r/nP/r/njs9=0.75/r/n×/r/n60/r/n=/r/n112.5/r/nKW/r/nQ/r/njs9=0.80/r/n×/r/n112.5/r/n=/r/n90/r/n/r/nKv/r/nar/r/n(/r/n7/r/n)生活區(qū):30KW/r/n整個(gè)施工現(xiàn)場的計(jì)算負(fù)荷,干線同期系數(shù)取K/r/nd/r/n=0.8/r/nPj/r/ns/r/n=K/r/nx/r/n·∑/r/nPj/r/ns/r/n=0./r/n8/r/n×(/r/n18/r/n+/r/n14.76/r/n+/r/n83.85/r/n+/r/n10.8/r/n+/r/n45/r/n+/r/n112.5+30/r/n)KW/r/n=/r/n251.93/r/nKW/r/nQj=K/r/nx/r/n·∑/r/nQj/r/ns/r/n=0./r/n8/r/n×(/r/n13.5+/r/n11.07/r/n+/r/n62.89/r/n+/r/n8.64/r/n+/r/n36/r/n+/r/n90+/r/n30/r/n)K/r/nW/r/n=/r/n146.37/r/nK/r/nVA/r/nSjs=/r/n√/r/n(251.93/r/n2/r/n+146.37/r/n2/r/n)=322.713KVA/r/n/r/n經(jīng)過和業(yè)主的協(xié)商,在/r/n業(yè)主配電室/r/n提供/r/n800/r/nKVA/r/n變壓器及/r/n1000A/r/n駁接口,引電源至配電房,設(shè)電表計(jì)量。/r/n3、導(dǎo)線的選擇:/r/n本著安全第一的原則,現(xiàn)場的主干線路均采用/r/n塑料鋁芯線架空敷設(shè)/r/n。根據(jù)以上的回路計(jì)算電流,按長期允許載流量、溫升/r/nC=25/r/n℃/r/n來選擇:/r/n回路/r/n電流/r/n:/r/nI/r/njs/r/n=S/r/njs/r/n//r/n(/r/nЗ/r/n1/2/r/n×/r/nU/r/n)/r/n=/r/n435.8A/r/n查電工手冊/r/n240/r/nmm/r/n2/r/n鋁芯/r/n絕緣導(dǎo)線在/r/nTm=65/r/n℃/r/n時(shí)的載流量為/r/n≤/r/n/r/n460/r/nA/r/n,故選/r/n240/r/nmm/r/n2/r/n鋁芯/r/n絕緣導(dǎo)線作相線、工作零線,/r/n120/r/nmm/r/n2/r/n鋁芯/r/n絕緣導(dǎo)線做保護(hù)零線(/r/nPE/r/n線)。/r/n/r/n生活區(qū)回路/r/n:/r/n考慮到生活及辦公一體,故/r/n選50/r/nmm/r/n2/r/n銅芯電纜線作相線、工作零線,25/r/nmm/r/n2/r/n銅芯電纜線做保護(hù)零線(/r/nPE/r/n線)。/r/n材料計(jì)劃/r/nBL/r/nVV4*/r/n240/r/n+1*/r/n120/r/nmm/r/n2/r/n鋁芯電線/r/n/r/n米(視現(xiàn)場而定)/r/nB/r/nVV4*/r/n3/r/n0/r/n+1*/r/n16/r/nmm/r/n2/r/n銅芯電纜/r/n/r/n米(視現(xiàn)場而定)/r/nB/r/nVV4*/r/n2/r/n5/r/n+1*16/r/nmm/r/n2/r/n銅芯電纜/r/n/r/n米(視現(xiàn)場而定)/r/nB/r/nVV4*25+1*16/r/nmm/r/n2/r/n銅芯電纜/r/n/r/n米(視現(xiàn)場而定)/r/nB/r/nVV5*16/r/nmm/r/n2/r/n銅芯電纜/r/n/r/n米(視現(xiàn)場而定)/r/n三、開關(guān)設(shè)備選用/r/n由于閃光對焊機(jī)、鋼筋加工廠/r/n負(fù)荷比較大/r/n,均采取單獨(dú)回路供電。/r/n1、閃光焊機(jī):按一臺(tái)計(jì)75KW,按公式/r/nI/r/njs/r/n=S/r/njs/r/n//r/n(/r/nЗ/r/n1/2/r/n×/r/nU/r/n)/r/n經(jīng)計(jì)算電流為117.1A,查銅芯導(dǎo)線的允許載流量表應(yīng)選取50㎜/r/n2/r/n銅芯導(dǎo)線可滿足要求,選取電纜線VV-4*50+1*25。隔離開關(guān)規(guī)格選擇160A,漏電開關(guān)規(guī)格選擇160A,漏電動(dòng)作電流為100mA,漏電動(dòng)作時(shí)間<0.1s。/r/n2.1、鋼筋加工場回路:總?cè)萘坑?jì)/r/n53/r/nKW,按公式/r/nI/r/njs/r/n=S/r/njs/r/n//r/n(/r/nЗ/r/n1/2/r/n×/r/nU/r/n)/r/n經(jīng)計(jì)算電流為/r/n75/r/nA,查銅芯導(dǎo)線的允許載流量表應(yīng)選取/r/n35/r/n㎜/r/n2/r/n銅芯導(dǎo)線可滿足要求,選取電纜線VV-4*/r/n3/r/n5+1*16。隔離開關(guān)規(guī)格選擇200A,漏電開關(guān)規(guī)格選擇200A,漏電動(dòng)作電流為100mA,漏電動(dòng)作時(shí)間<0.1s。/r/n2.2、各/r/n單體工程/r/n分配箱回路:總?cè)萘坑?jì)50KW,按公式/r/nI/r/njs/r/n=S/r/njs/r/n//r/n(/r/nЗ/r/n1/2/r/n×/r/nU/r/n)/r/n經(jīng)計(jì)算電流為7/r/n2/r/nA,查銅芯導(dǎo)線的允許載流量表應(yīng)選取25㎜/r/n2/r/n銅芯導(dǎo)線可滿足要求,選取電纜線VV-4*25+1*16。隔離開關(guān)規(guī)格選擇200A,漏電開關(guān)規(guī)格選擇200A,漏電動(dòng)作電流為100mA,漏電動(dòng)作時(shí)間<0.1s。/r/n3、由用電機(jī)具的操作開關(guān)所串接的漏電開關(guān)為第三級漏電保護(hù),其漏電動(dòng)作電流為30mA,漏電動(dòng)作時(shí)間<0.1s。/r/n其他功率小回路按此計(jì)算法取得電線、電纜、開關(guān)規(guī)格型號。/r/n附:/r/n銅芯絕緣導(dǎo)線長期連續(xù)負(fù)荷允許載流量表/r/n導(dǎo)線/r/n截面/r/n(/r/nmm2)/r/n線芯結(jié)構(gòu)/r/n導(dǎo)線明敷設(shè)/r/n橡皮絕緣導(dǎo)線多根同穿在一根管內(nèi)時(shí)/r/n允許負(fù)荷載流量(/r/nA)/r/n塑料絕緣導(dǎo)線多根同穿在一根管內(nèi)時(shí)/r/n允許負(fù)荷載流量(/r/nA)/r/n股數(shù)/r/n單芯/r/n直徑/r/n(/r/nmm)/r/n成品/r/n外經(jīng)/r/n(/r/nmm)/r/n30oC/r/n30oC/r/n30oC/r/n橡皮/r/n塑料/r/n穿金屬管/r/n穿塑料管/r/n穿金屬管/r/n穿金屬管/r/n2根/r/n3根/r/n4根/r/n2根/r/n3根/r/n4根/r/n2根/r/n3根/r/n4根/r/n2根/r/n3根/r/n4根/r/n1.0/r/n1/r/n1.13/r/n4.4/r/n20/r/n18/r/n14/r/n13/r/n11/r/n12/r/n11/r/n10/r/n13/r/n12/r/n10/r/n11/r/n10/r/n9/r/n1.5/r/n1/r/n1.37/r/n4.6/r/n25/r/n20/r/n19/r/n17/r/n16/r/n16/r/n15/r/n13/r/n18/r/n16/r/n15/r/n15/r/n14/r/n12/r/n2.5/r/n1/r/n1.76/r/n5.0/r/n33/r/n30/r/n26/r/n23/r/n22/r/n23/r/n21/r/n19/r/n24/r/n22/r/n21/r/n22/r/n20/r/n18/r/n4/r/n1/r/n2.24/r/n5.5/r/n42/r/n39/r/n35/r/n31/r/n28/r/n31/r/n28/r/n24/r/n33/r/n29/r/n26/r/n29/r/n26/r/n23/r/n6/r/n1/r/n2.73/r/n6.2/r/n54/r/n51/r/n46/r/n40/r/n36/r/n40/r/n36/r/n32/r/n44/r/n38/r/n35/r/n38/r/n34/r/n30/r/n10/r/n7/r/n1.33/r/n7.8/r/n79/r/n70/r/n64/r/n56/r/n50/r/n55/r/n49/r/n43/r/n61/r/n53/r/n47/r/n52/r/n46/r/n41/r/n16/r/n7/r/n1.68/r/n8.8/r/n103/r/n98/r/n80/r/n72/r/n65/r/n76/r/n68/r/n60/r/n77/r/n68/r/n61/r/n67/r/n61/r/n53/r/n25/r/n19/r/n1.28/r/n10.6/r/n135/r/n128/r/n106/r/n94/r/n84/r/n100/r/n90/r/n80/r/n100/r/n89/r/n80/r/n89/r/n80/r/n70/r/n35/r/n19/r/n1.51/r/n11.8/r/n168/r/n159/r/n131/r/n114/r/n103/r/n125/r/n110/r/n98/r/n124/r/n107/r/n98/r/n112/r/n98/r/n87/r/n50/r/n19/r/n1.81/r/n13.8/r/n215/r/n201/r/n163/r/n144/r/n128/r/n160/r/n140/r/n123/r/n154/r/n136/r/n121/r/n140/r/n123/r/n109/r/n70/r/n49/r/n1.33/r/n17.3/r/n266/r/n248/r/n201/r/n180/r/n162/r/n195/r/n175/r/n155/r/n192/r/n171/r/n154/r/n173/r/n156/r/n138/r/n95/r/n84/r/n1.20/r/n20.8/r/n322/r/n304/r/n241/r/n220/r/n197/r/n240/r/n215/r/n195/r/n234/r/n210/r/n187/r/n215/r/n192/r/n173/r/n120/r/n133/r/n1.08/r/n21.7/r/n374/r/n350/r/n280/r/n252/r/n229/r/n260/r/n234/r/n212/r/n266/r/n248/r/n215/r/n248/r/n224/r/n201/r/n150/r/n37/r/n2.24/r/n22.0/r/n440/r/n402/r/n318/r/n290/r/n262/r/n299/r/n271/r/n248/r/n299/r/n276/r/n252/r/n285/r/n262/r/n234/r/n185/r/n/r/n/r/n/r/n504/r/n458/r/n359/r/n331/r/n299/r/n336/r/n308/r/n280/r/n355/r/n317/r/n280/r/n331/r/n289/r/n261/r/n1、總配電箱設(shè)置:/r/n根據(jù)/r/nJGJ46-/r/n2005規(guī)范規(guī)定,設(shè)置配電室及室內(nèi)配電總配電箱1個(gè)??偱潆娤鋬?nèi)置總配電箱/r/n內(nèi)母線/r/n應(yīng)/r/n涂刷有色油漆,以標(biāo)志相序方向?yàn)榛鶞?zhǔn),L1(A)黃/r/n、/r/nL2(B)綠/r/n、/r/nL3(C)紅/r/n、/r/nN淡藍(lán)/r/n、PE黃/綠;總配電箱/r/n設(shè)電度表,并應(yīng)裝設(shè)電流、電壓表。電流表與計(jì)費(fèi)電度表/r/n使用兩組不同的/r/n電流互感器。/r/n(詳見配電柜系統(tǒng)圖)/r/n2、/r/n配電室/r/n設(shè)置:/r/n配電室供電采用TN-S系統(tǒng)接零保護(hù)。/r/n總配電箱/r/n與重復(fù)接地線及保護(hù)零線做電氣連接。配電室應(yīng)/r/n有/r/n自然通風(fēng)措施/r/n,/r/n并應(yīng)采取防止雨雪侵入和動(dòng)物侵入的措施。配電室布置應(yīng)符合下列要求:/r/n總配電箱/r/n正面的操作通道寬度不小于/r/n1.5/r/nm/r/n;/r/n/r/n總配電箱/r/n后面的維護(hù)通道寬度,單列布置或雙列面對面布置不小于/r/n0.8m;/r/n/r/n總配電箱/r/n側(cè)面的維護(hù)通道寬度不小于lm/r/n;/r/n配電室的頂棚與地面的距離不低于3m;/r/n總配電箱/r/n的上端距頂棚不小于/r/n0./r/n5m;配電室的門向外開,并配鎖/r/n;/r/n配電室的照明分別設(shè)置正常照明和事故照明。/r/n電柜安裝:電流表三只,互感器三只,電壓換相開關(guān)一只,停送電指示燈,630A刀閘總開關(guān),4個(gè)400A隔離和4個(gè)400A漏電,其漏電動(dòng)作電流為100mA,漏電動(dòng)作時(shí)間為可調(diào)型/r/n≤/r/n0.1S~0.3S/r/n。/r/n3、/r/n分配電箱,分動(dòng)力專用箱及照明專用箱設(shè)置:/r/n分/r/n配電箱、開關(guān)箱內(nèi)的電器/r/n是靈敏/r/n可靠、/r/n性能/r/n完好的電器。/r/n開關(guān)箱根據(jù)施工的需要,由各配電箱與分配電箱引出,開關(guān)箱與分配電箱的距離不超過/r/n30/r/n米。開關(guān)箱與所控制的固定式用電設(shè)備的水平距離控制在/r/n2.5/r/n米以內(nèi),且開關(guān)箱要保證一機(jī)一箱一閘一漏電的要求。/r/n固定式分配電箱和開關(guān)箱的下底面與地面垂直距離控制在1.4~1.6米,移動(dòng)式分配電箱和開關(guān)箱下底與地面的距離在0.8~1.6米,各配電箱裝設(shè)環(huán)境應(yīng)能滿足二人同時(shí)作業(yè)的空間和通道,且不妨礙操作和維修的物品和易燃品。/r/n配電箱要有分別的編號,標(biāo)明用途,電箱負(fù)責(zé)人。動(dòng)力箱與照明箱分開設(shè)置,配線排列整齊,不使用破損、不合格的電器。電箱的進(jìn)出線從箱底進(jìn)出,并有防護(hù)套,箱內(nèi)無雜物,所有電箱防雨、防臺(tái)風(fēng)、防塵。(詳見配電箱系統(tǒng)圖)/r/n4、/r/n防雷/r/n及接地/r/n根據(jù)現(xiàn)行規(guī)范,為保證配電系統(tǒng)安全可靠性和防止觸電,必須在系統(tǒng)中采用TN-S保護(hù)系統(tǒng)。該工程電力變壓器中性點(diǎn)直接接地作為系統(tǒng)的工作接地,從配電房引出的PE專用接地線作為保護(hù)接地,配電柜接地電阻應(yīng)小于4歐。在系統(tǒng)中PE線設(shè)置不少于三處的重復(fù)接地。首處在配電室總配電柜處(可并在變壓器接地體上),其它分別在各主回路的分配電箱的下端,重復(fù)接地體接地電阻應(yīng)小于10歐。/r/n在施工現(xiàn)場施工最高點(diǎn),如施工井架的頂端:按標(biāo)準(zhǔn)設(shè)置避雷針,并進(jìn)行接地,接地電阻符合要求/r/n。避雷保護(hù)范圍視具體情況而定,按照滾球法來進(jìn)行校核,,采用/r/nФ/r/n20鍍鋅鋼管,長度大于2米,引下線為BV25㎜/r/n2/r/n銅芯線,下面與預(yù)留的防雷接地體連接,防雷沖擊電阻不得大于30/r/nΩ/r/n。/r/n5、備用電源/r/n/r/n為了預(yù)防市電網(wǎng)停電日的情況,保證不間斷電源,特別是砼澆筑的連續(xù),辦公區(qū)需要常備照明及空調(diào)負(fù)荷約20KW。為保證市電停電情況下不可間斷工序的正常開展,下列設(shè)備負(fù)荷應(yīng)成為市電停電時(shí)的必須負(fù)荷。/r/n序/r/n號/r/n機(jī)械名稱/r/n型號/r/n單機(jī)功率/r/n(KW)/r/n臺(tái)數(shù)/r/n總功率/r/n(kW)/r/n備注/r/n1/r/n加壓水泵/r/n3/r/n1/r/n3/r/n臨時(shí)消防及施工臨水/r/n電動(dòng)機(jī)功率合計(jì):P1=127KW/r/n1/r/n辦公區(qū)、生活區(qū)照明負(fù)荷功率/r/n30/r/n2/r/n室外照明負(fù)荷功率/r/n9/r/n照明功率合計(jì):P3=42KW/r/nP=0.8/r/n×/r/n42=33.60(KW)/r/n/r/n根據(jù)計(jì)算結(jié)果,我公司進(jìn)場施工后,將安裝1臺(tái)50KW的柴油發(fā)電機(jī)作備用電源。發(fā)電機(jī)組工作接地電阻要求<4/r/nΩ/r/n。安裝時(shí)須執(zhí)行以下操作規(guī)程:/r/n/r/n=1\*GB3/r/n/r/n①/r/n、安裝、大修或停用的發(fā)電機(jī),使用前應(yīng)測量定子和勵(lì)磁回路的絕緣電阻以及吸收比,定子的絕緣電阻不得低于上次所測值的30%,勵(lì)磁回路的絕緣電阻不得低于0.5M歐,吸收比值不得小于1.3,并做好測量記錄。/r/n/r/n/r/n=2\*GB3/r/n/r/n②/r/n、作業(yè)前檢查發(fā)電機(jī)傳動(dòng)部分,應(yīng)連接可靠,輸出線路絕緣良好,各儀表齊全、有效。啟動(dòng)前應(yīng)先將勵(lì)磁變阻值放在最大位置上,然后切斷供電輸出主開關(guān),接合中性點(diǎn)接地開關(guān)。應(yīng)先啟動(dòng)發(fā)電機(jī)空轉(zhuǎn),待正常后再接合發(fā)電機(jī)。/r/n/r/n/r/n=3\*GB3/r/n/r/n③/r/n、啟動(dòng)后檢查發(fā)電機(jī)在升速中應(yīng)無異響,滑環(huán)及整流子上電刷接觸良好,無跳動(dòng)及冒火花現(xiàn)象。待運(yùn)轉(zhuǎn)穩(wěn)定,頻率、電壓達(dá)到額定值后,方可向外供電。載荷應(yīng)逐步增大,三相應(yīng)保持平衡。發(fā)電機(jī)開始運(yùn)轉(zhuǎn)后,即應(yīng)認(rèn)為全部電氣設(shè)備均已帶電。發(fā)電機(jī)連續(xù)運(yùn)行的最高和最低允許電壓值不得超過額定值的正負(fù)10%。其正常運(yùn)行的電壓變動(dòng)范圍應(yīng)在額定值的正負(fù)5%以內(nèi),功率因數(shù)為額定值時(shí),發(fā)電機(jī)額定容量不變。發(fā)電機(jī)在額定頻率值運(yùn)行時(shí),其變動(dòng)范圍不得超過正負(fù)5HZ。發(fā)電機(jī)功率因數(shù)不得超過遲相(滯后)0.95。有自動(dòng)勵(lì)磁調(diào)節(jié)裝置的,可在功率因數(shù)為1的條件下運(yùn)行,必要時(shí)可允許短時(shí)間在遲相1.95/r/n~/r/n1的范圍內(nèi)運(yùn)行。發(fā)電機(jī)運(yùn)行中應(yīng)經(jīng)常檢查并確認(rèn)各儀表指示及各運(yùn)轉(zhuǎn)部分正常,并應(yīng)隨時(shí)調(diào)整發(fā)電機(jī)的載荷。/r/n/r/n/r/n=4\*GB3/r/n/r/n④/r/n、停機(jī)前應(yīng)先切斷各供電分路,逐步減少載荷,然后切斷發(fā)電機(jī)供電主開關(guān),將勵(lì)磁變阻器復(fù)位到電阻最大值位置,使電壓降至最低值,再切斷勵(lì)磁開關(guān)和中性點(diǎn)接地開關(guān),最后停止發(fā)電機(jī)運(yùn)轉(zhuǎn)。發(fā)電機(jī)組始終處于準(zhǔn)備起動(dòng)狀態(tài),當(dāng)確定發(fā)生市電中斷時(shí),機(jī)組在15秒內(nèi)投入并帶負(fù)荷運(yùn)行,發(fā)電機(jī)電源和市政電源的切換設(shè)機(jī)械及電氣聯(lián)鎖裝置,使其與變壓器不得并列運(yùn)行。發(fā)電機(jī)組低壓配電系統(tǒng)其聯(lián)絡(luò)開關(guān)常開,市電停電后,聯(lián)絡(luò)開關(guān)自動(dòng)合上,市電恢復(fù)后該開關(guān)自動(dòng)分?jǐn)?,此電氣?lián)鎖由PLC控制器實(shí)現(xiàn)。/r/n6、本工程臨時(shí)用水主要包括生活用水及施工用水,最高峰應(yīng)滿足150人的需求。臨時(shí)施工用水均直接按/r/n建設(shè)單位提供的水源點(diǎn)駁接,裝水表計(jì)量。/r/n四、臨時(shí)用水/r/n因主體施工采用商品砼,現(xiàn)場施工用水主要集中在混凝土的養(yǎng)護(hù)和砂漿的攪拌上,施工用水:混凝土養(yǎng)護(hù)5L/m/r/n2/r/n,砂漿攪拌150L/m/r/n3/r/n,總用水量按最不利考慮,施工高峰期每臺(tái)班工作量為:砂漿攪拌100m/r/n3/r/n,混凝土養(yǎng)護(hù)250m/r/n2/r/n。/r/nnQ/r/n1/r/n./r/nN/r/n1/r/n1.5/r/nq/r/n1/r/n=K/r/n1/r/nK/r/n2/r/nΣ/r/n/r/n×/r/nn=1T/r/n1/r/n./r/nt8/r/n×/r/n3600/r/n1.5/r/nq/r/n1/r/n=1.1/r/n3/r/n[+5/r/n3/r/n250]/r/n3/r/n/r/n=0.93L//r/ns/r/nq/r/n1/r/n施工用水量(L/s)/r/nK/r/n1/r/n未預(yù)計(jì)的施工用水系數(shù)取1.1/r/nQ/r/n1/r/n日工程量/r/nN/r/n1/r/n施工用水定額/r/n/r/nT/r/n1/r/n有效工作日,按天計(jì)算/r/n/r/nt每天工作班數(shù)/r/n/r/nK/r/n2/r/n用水不均衡系數(shù)取1.5/r/n考慮高峰用水不確定因素,應(yīng)選擇提供用水流量不小于2L/s的接駁口,我司采用DN65給水管。/r/n/r/n=2\*GB3/r/n/r/n②/r/n消防用水/r/n本工程最高/r/n高度9.05米,共2層,市政供水一般為12.00米。為了達(dá)到臨時(shí)施工用水高度,滿足消防用水要求,我司在3#池東邊建10m3消防水池。水泵選用廣州第一水泵廠產(chǎn)品:IS60-50-160B-3KW臥式單級單吸水泵揚(yáng)程24米。在水泵的出水口安裝回水管,防止長時(shí)間加壓,導(dǎo)致臨時(shí)水管內(nèi)水壓過高而破裂。平均設(shè)置臨時(shí)水與消防水公用管1條,每層安裝消防栓,覆蓋面為90.0米;為了滿足消防要求,我司在消防栓不能覆蓋位置放置滅火器。/r/n五、臨時(shí)/r/n水電總平面(見附圖)/r/n/r/n六、安全用電技術(shù)措施/r/n1、配電室設(shè)在無灰塵、無腐蝕介質(zhì)及無振動(dòng)的地方。總配電箱兩端與重復(fù)接地線及保護(hù)零線做電氣連接。配電室門必須外開且用全封鋼板門。/r/n2、工程臨時(shí)施工用電安全/r/n運(yùn)行/r/n必須按本施工組織設(shè)計(jì)設(shè)置接地和接零。所有接地處必須保證可靠電器連接,專用保護(hù)零線必須用黃綠雙色多股銅芯軟線。嚴(yán)禁與相線及工作零線混用,電氣設(shè)備的設(shè)置安裝、防護(hù)、使用及維護(hù),操作人員的使用必須符合JGJ46-2005規(guī)范中有關(guān)規(guī)定。/r/n3、配電箱及開關(guān)箱中的電氣裝置/r/n完好/r/n,連接牢固,各接頭緊固,接觸良好,無過熱現(xiàn)象,各配電箱、開關(guān)箱標(biāo)明回路號、用途名稱、/r/n編號/r/n、責(zé)任人并配鎖。/r/n在危險(xiǎn)場所、潮濕及易觸電的場所采用/r/n安全電壓/r/n,/r/n安全電壓/r/n不大于24V供電。/r/n4、建立健全的臨時(shí)用電施工組織設(shè)計(jì)和安全用電技術(shù)措施交底制度。/r/n建立安全檢測巡視制度,加強(qiáng)職業(yè)/r/n安/r/n全用電教育,建立健全安全運(yùn)行記錄、維修記錄、確保停電檢修制度的實(shí)施,防止誤送電、倒送電的現(xiàn)象。/r/n5、凡不符合JGJ46-2005規(guī)定的非/r/n電氣/r/n專業(yè)人員嚴(yán)禁在系統(tǒng)內(nèi)亂接線,以及檢修電氣設(shè)備等一切有關(guān)工作。/r/n6、/r/n/r/n雷雨天氣嚴(yán)禁高空作業(yè),高空作業(yè)要戴好安全帽,系好安全帶,上、下傳送物件要用繩吊,嚴(yán)禁拋擲。/r/n7/r/n、維修用的儀表、工具、高壓絕緣棒、絕緣手套、絕緣鞋要妥善保管,并定期到有關(guān)部門檢測。/r/n/r/n8、/r/n/r/n線路、設(shè)備跳閘后示檢查原因,未排除故障不準(zhǔn)強(qiáng)行送電。/r/n9、/r/n/r/n停電維修時(shí),要懸掛警示牌,鎖好電箱門,要有明顯的斷開點(diǎn),并進(jìn)行驗(yàn)電和放電,一切工作完成后,由關(guān)閘人送電(送電實(shí)行三次送電),嚴(yán)禁約時(shí)送電。/r/n/r/n10、/r/n/r/n嚴(yán)格遵循停送電程序。送電時(shí),總配電箱分配電箱開、關(guān)箱;停電時(shí),開關(guān)箱分配電箱總配電箱。/r/n/r/n/r/n11、/r/n/r/n使用潛水泵,必須裝有單獨(dú)的開關(guān)箱,有靈敏可靠的漏電保護(hù)器,進(jìn)入水中的電纜不得有接頭,移動(dòng)時(shí)必須切斷電源,應(yīng)有兩人同時(shí)時(shí)進(jìn)行,移動(dòng)潛水泵不得將電纜線作吊繩。/r/n/r/n12、/r/n/r/n電氣工作人員,定期組織學(xué)習(xí)培訓(xùn),掌握安全用電規(guī)程和觸電急救的技能,有權(quán)制止一切違章用電現(xiàn)象。/r/n/r/n13、/r/n各類設(shè)備在未接通電源前,必須進(jìn)行絕緣電阻檢測,其阻值不小于/r/n0.5M/r/nΩ/r/n,手動(dòng)工具及潛水泵的絕緣電阻不小于/r/n1.0M/r/nΩ/r/n。/r/n/r/n/r/n14、/r/n/r/n教育全體職工掌握安全用電常識和電氣防火,滅火基本知識,發(fā)現(xiàn)火情立即切斷電源,組織滅火并立即報(bào)告消防部門搶救,嚴(yán)禁用水和其它導(dǎo)電解質(zhì)滅火,防止發(fā)生觸電事故。/r/n15、/r/n/r/n現(xiàn)場電工要懂得和學(xué)會(huì)急救,有人發(fā)生觸電事故時(shí),首先盡快斷開電源,除報(bào)急救中心外,立即組織搶救:1人工呼吸法;2胸外心臟擠壓法。/r/n七、/r/n安全用電/r/n防火措施/r/n1、配電室的耐火等級不應(yīng)低于三級,室內(nèi)不得存放易燃、易爆物品,并應(yīng)配備砂箱、干粉滅火器等絕緣滅火材料。電氣設(shè)備和電線用電不準(zhǔn)超過安全負(fù)荷,接頭處要牢固,絕緣性良好。/r/n2、合理配置、檢修、整改、更新各種保護(hù)電器,對電路和設(shè)備的過載、短路等故障進(jìn)行可靠保護(hù)。/r/n3、在電氣裝置和線路周圍不堆放易燃、易爆和強(qiáng)腐蝕性物質(zhì),不使用火源。/r/n4、在用電設(shè)備較集中的/r/n施工/r/n現(xiàn)場應(yīng)配置一定數(shù)量的干粉式(1211)滅火器和用于滅火的絕緣工具,并禁止煙火。配電室內(nèi)配備滅火器及干沙。/r/n5、強(qiáng)電器設(shè)備、線路、相與地的絕緣,防止閃爍、接地電阻過大而產(chǎn)生的高溫、高熱現(xiàn)象,并合理設(shè)置防雷/r/n裝置/r/n。/r/n6、宿舍內(nèi)嚴(yán)禁使用電氣設(shè)備燒開水、做飯等,照明所用的燈具功率不得超過40W,嚴(yán)禁工人亂拉亂接電線。/r/n7、所有電氣操作人員必須持證上崗,嚴(yán)禁非電業(yè)人員從事電氣作業(yè),電氣人員要嚴(yán)格執(zhí)行《施工現(xiàn)場臨時(shí)用電安全技術(shù)規(guī)范》/r/nJGJ46/r/n——/r/n2005/r/n,做到明確分工,責(zé)任到人,堅(jiān)持勤巡視,勤檢查。/r/n施工現(xiàn)場一旦發(fā)生火災(zāi),撲滅時(shí)應(yīng)注意以下事項(xiàng):/r/n(/r/n1/r/n)/r/n、迅速切斷電源,避免事態(tài)擴(kuò)大。/r/n(/r/n2/r/n)/r/n、當(dāng)電源因其它原因不能及時(shí)切斷時(shí),一方面派人去供電端拉閘,另一方面滅火時(shí)人體的各部位與帶電體應(yīng)保持一定的距離,并必須穿戴絕緣用品。/r/n(/r/n3/r/n)/r/n、撲面電氣火災(zāi)時(shí),要用絕緣性良好的滅火器,如干粉滅火器、/r/nCO/r/n2/r/n滅火器或干燥砂子,嚴(yán)禁使用/r/n水或泡沫/r/n撲救。/r/n八/r/n、/r/n應(yīng)急預(yù)案/r/n1、項(xiàng)目電工在臨時(shí)用電系統(tǒng)的組織施工過程中,項(xiàng)目必須對作業(yè)人員進(jìn)行有關(guān)方面的《安全技術(shù)交底》,做到作業(yè)人員心中有數(shù),杜絕作業(yè)安全事故的發(fā)生。/r/n2、臨時(shí)施工用電工程施工完成后,項(xiàng)目必須對現(xiàn)場進(jìn)行一次全面的檢查。包括對相-相、相-地間絕緣電阻進(jìn)行測量;對各處接地電阻進(jìn)行測量。并做好記錄,備驗(yàn)。/r/n3、施工用電工程只有在經(jīng)公司相關(guān)部門驗(yàn)收后,才能投入使用。項(xiàng)目上完成施工用電工程后,應(yīng)及時(shí)通知公司相關(guān)部門進(jìn)行驗(yàn)收。并配合公司的驗(yàn)收工作。/r/n4、觸電急救/r/n在保護(hù)措施不完備的情況下,人體觸電傷害事故是極易發(fā)生的。此時(shí)應(yīng)采取急

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論