常用管材(鋼管)規(guī)格表_第1頁
常用管材(鋼管)規(guī)格表_第2頁
常用管材(鋼管)規(guī)格表_第3頁
常用管材(鋼管)規(guī)格表_第4頁
常用管材(鋼管)規(guī)格表_第5頁
已閱讀5頁,還剩10頁未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)

文檔簡介

實用標(biāo)準(zhǔn)常用管材(鋼管)規(guī)格表(A)公稱直焊接鋼管(普通)焊接鋼管(加厚)無縫鋼管(熱軋)徑GB3091-82GB83092-82螺旋電焊鋼管GB8163-87DNpg≤1.0Mpapg≤1.6Mpapg≤2.5Mpapg≤1.6MpaD×∮重量D×∮重量D×∮重量D×∮重量(Kg/m)(Kg/m)(Kg/m)(Kg/m)DN1521.3*2.71.2521.3*3.21.44----------------55DN2026.8*2.71.6326.8*3.52.01----------------5DN2533.5*3.22.4233.5*42.9132*3.52.46--------5DN3242.3*3.23.1342.3*43.7738*3.52.98--------5DN4048*3.53.8448*4.254.5845*3.53.58--------DN5060*3.54.8860*4.56.1657*3.54.62--------DN6575.5*3.76.6475.5*4.57.8873*46.81--------5DN8088.5*48.3488.5*4.79.8189*48.38--------5DN100114*410.85114*513.44108*410.26--------DN125140*4.515.04140*4.518.24133*412.72--------DN150165*4.517.81165*5.521.63159*4.17.14168*520.105DN200----------------219*631.52219*531.52DN250----------------273*852.28273*745.92DN300----------------325*862.54325*754.90DN350----------------377*981.67377*763.87DN400----------------426*992.55426*772.33DN450----------------480*9104.53478*781.31DN500----------------530*9115.62529*790.11DN600----------------630*9137.82630*7107.50文案大全實用標(biāo)準(zhǔn)常用管材(鋼管)規(guī)格表(B)公稱焊接鋼管(普通)焊接鋼管(加厚)無縫鋼管(熱軋)直徑螺旋電焊鋼管GB3091-82GB83092-82GB8163-87DNpg≤1.0Mpapg≤1.6Mpapg≤2.5Mpapg≤1.6MpaD×∮VD×∮VD×∮VD×VM3/100mM3/100mM3/100m∮M3/100mDN1521.3*2.0.0221.3*3.0.017----------------7525DN2026.8*2.0.03626.8*3.0.031----------------755DN2533.5*3.0.05733.5*40.05132*3.50.049--------25DN3242.3*3.0.1042.3*40.09238*3.50.075--------25DN4048*3.50.013248*4.250.1245*3.50.11--------DN5060*3.50.2260*4.50.2057*3.50.20--------DN6575.5*3.0.3675.5*4.0.3573*40.33--------755DN8088.5*40.5188.5*4.0.4989*40.52--------75DN100114*40.88114*50.85108*40.79--------DN125140*4.51.35140*4.51.35133*41.23--------DN150165*4.51.91165*5.51.86159*4.1.76168*1.9655DN200----------------219*63.36219*3.435DN250----------------273*85.18273*5.277DN300----------------325*87.49325*7.597DN350----------------377*910.12377*10.347文案大全實用標(biāo)準(zhǔn)DN400----------------426*913.07426*13.327DN450----------------480*916.76478*16.907DN500----------------530*920.58529*20.827DN600----------------630*929.40630*29.797常用型材的理論重量 (Kg/m)扁鋼:鍍鋅板:-25×3-----0.59δ0.5=7.85kg/張(2m2)-30×3-----0.71δ0.6=9.42kg/張(2m2)-40×4-----1.76δ0.75=11.78kg/張(2m2)角鋼:δ1.0=15.7kg/張(2m2)∟∠25×3-----1.24δ1.2=18.84kg/張(2m2)30×3-----1.373∠40×4-----2.422鋼板重量計算公式:∟∠50×5-----3.77G=L×B×H×7.85槽鋼:G:重量,L:長,B:寬,H:厚6.3#-----6.33計算時注意保證單位一致8#-----8.0510#----10.0012#----12.02圓鋼:6----0.2228----0.395文案大全實用標(biāo)準(zhǔn)10---0.61712---0.88814---1.21φ16---1.5816---1.58商用空調(diào)各類場所應(yīng)用經(jīng)驗行業(yè)場所方案實例餐廳:空間不大,規(guī)模較小的餐廳可以使用低靜壓管道機(jī)組,以達(dá)到經(jīng)濟(jì)實惠的效果。而高檔次的餐廳可以使用嵌入式空調(diào)機(jī)組,以體現(xiàn)整體環(huán)境的高雅大方??臻g開闊和包房較多的餐廳應(yīng)選擇不同的空調(diào),具體可參照娛樂場所的選擇方案。便利店:便利店的空間有限,使用低靜壓管道機(jī)組和嵌入式空調(diào)機(jī)組就能很好地滿足此類場所的空調(diào)要求。而且空調(diào)懸掛于空間頂部,不會占據(jù)任何營業(yè)空間。娛樂場所:空間開闊的娛樂場所建議使用高靜壓風(fēng)管機(jī)組,以達(dá)到送風(fēng)均勻,快速制冷的效果。而有較多包間的場所可以使用風(fēng)冷熱泵機(jī)組, 以方便每個房間單獨(dú)控制。汽車展示廳:汽車展示廳通??煞譃檎故緟^(qū)域和辦公區(qū)域,展示部分可以選用高靜壓管道機(jī)組,而辦公部分可以使用風(fēng)冷熱泵機(jī)組,以分別滿足兩個區(qū)域不同的空調(diào)要求。小型辦公樓:建議使用風(fēng)冷熱泵機(jī)組以便于分層控制,或者分區(qū)域控制。工廠:水冷柜機(jī)由于其價格性能比高,是工廠選用空調(diào)的最佳選擇。超市及大賣場:超市及大買場的空間開闊,客流量大,大風(fēng)量設(shè)計的高靜壓管道機(jī)組是此類場所的最佳選擇。文案大全實用標(biāo)準(zhǔn)末端的選型1、 風(fēng)機(jī)盤管的選型風(fēng)機(jī)盤管有兩個主要參數(shù):制冷(熱)量和送風(fēng)量,故有風(fēng)機(jī)盤管的選擇有如下兩種方法:1)根據(jù)房間循環(huán)風(fēng)量選:房間面積、層高(吊頂后)和房間換氣次數(shù)三者的乘積即為房間的循環(huán)風(fēng)量。利用循環(huán)風(fēng)量對應(yīng)風(fēng)機(jī)盤管高速風(fēng)量,即可確定風(fēng)機(jī)盤管型號。2)根據(jù)房間所需的冷負(fù)荷選擇:根據(jù)單位面積負(fù)荷和房間面積,可得到房間所需的冷負(fù)荷值。利用房間冷負(fù)荷對應(yīng)風(fēng)機(jī)盤管的高速風(fēng)量時的制冷量即可確定風(fēng)機(jī)盤管型號。確定型號以后,還需確定風(fēng)機(jī)盤管的安裝方式(明裝或安裝),送回風(fēng)方式(下送下回,側(cè)送下回等)以及水管連接位置(左或右)等條件。注:房間面積較大時應(yīng)考慮使用多個風(fēng)機(jī)盤管,房間單位面積負(fù)荷較大,對噪音要求不高時可考慮使用風(fēng)量和制冷量較大的風(fēng)機(jī)盤管。2、 空氣處理機(jī)組的選型空氣處理機(jī)組主要用于處理室內(nèi)空氣和供新風(fēng),一般有空調(diào)工況和新風(fēng)工況兩種工作狀態(tài)??諝馓幚頇C(jī)組的選擇一般由三個主要參數(shù)決定:風(fēng)量、表冷器排管數(shù)和機(jī)外余壓。先根據(jù)系統(tǒng)需要的風(fēng)量確定空氣處理機(jī)組的型號,然后根據(jù)需要提供的冷量來決定其排管數(shù),如此便可確定。根據(jù)系統(tǒng)需要的余壓要求確定余壓。空氣處理機(jī)組一般有吊頂式和落地式兩種。落地式包括立式和臥式兩種。另外機(jī)組的送回風(fēng)方式也有諸多不同。應(yīng)根據(jù)建筑情況和建筑業(yè)主要求進(jìn)行最終的確定。質(zhì)量單位換算表質(zhì)量單位換算表千克(公斤)盎司(常衡)噸(t)磅(lb)(kg)(OZ)公制(t)美制(USton)英制(Ukton)12.204635.2740.0010.00110230.000984210.453591160.000453590.00050.000446430.0283500.062510.0000283500.000031250.00002790210002204.63527411.10230.98421907.1852000320000.90718510.892867文案大全實用標(biāo)準(zhǔn)1016.05 2240 35840 1.01605 1.12 1面積單位換算表面積單位換算表平方米(m2)平方英寸(in2)平方英尺(ft2)平方碼(yd2)11550.0010.76391.19606.4519×10-416.9444×10-37.716×10-40.092914410.11110.8361129691制冷量單位換算表制冷量單位換算表瓦(W)千焦/時千卡/時美國冷噸日本冷噸新英國冷噸英熱單位/時(kJ/h)(kcal/h)(Btu/h)13.60.859852.843×10-42.5899×10-42.395×10-43.41190.277810.238857.8983×10-57.1942×10-56.6542×10-50.94781.1634.186813.3069×10-43.012×10-42.786×10-43.96843516.912660.9302410.910840.842461.2×1043861.113900.233201.0978810.924951.3175×1044171.515028.13589.41.1871.0811711.4244×1040.293071.055070.2528.33×10-57.59×10-57.02034×10-51比焓單位換算表比焓單位換算表焦/千克爾格/千克(erg/kg)千卡/千克(kcal/kg)英尺.磅力/千克千克力.米/千克英熱單位/磅(Btu/lb)(J/kg)(ft.lbf/lb)(kgf.m/kg)11×1070.238846×10-30.3345530.1019720.429923×10-3文案大全實用標(biāo)準(zhǔn)1×10-710.238846×10-100.334553×10-70.101972×10-70.429923×10-104186.84.1868×101011400.70426.9351.82.989072.98907×1077.13926×10-410.30481.28507×10-39.806659.80665×1072.34228×10-33.2808414.21610×10-323262.326×10-100.555556778.169237.1861水系統(tǒng)設(shè)計按經(jīng)濟(jì)流速選用的水流速推薦值水系統(tǒng)設(shè)計按經(jīng)濟(jì)流速選用的水流速推薦值管道種類推薦流速m/s管道種類推薦流速m/s水泵吸入口1.2-2.1冷卻水管1.0-2.4水泵壓出口2.4-3.6分水器1.0-1.5供回水干管1.0-2.0集水器1.0-1.5供回水支管0.5-0.7排水管1.2-2.0設(shè)備水壓力降估算設(shè)備水壓力降估算離心式冷水機(jī)組吸收式冷水機(jī)組熱交換設(shè)備冷卻塔冷熱水排管風(fēng)機(jī)盤管調(diào)節(jié)閥器蒸發(fā)器冷凝器蒸發(fā)器冷凝器壓力降Kpa50-10010-10060-16060-16020-8020-5020-5010-2030-50各類建筑物冷負(fù)荷估算指標(biāo)各類建筑物冷負(fù)荷估算指標(biāo)適用場所辦公室客房圖書館辦公室(周邊區(qū)域)診所(中心區(qū)域)公寓零售店百貨店(上)單位面積W/?O100125150175200單位面積TR/?O0.0280.0360.0430.050.057適用場所百貨店(中)、大廳百貨店(下)會議室、戲院、會堂餐廳餐廳(頂)文案大全實用標(biāo)準(zhǔn)單位面積W/?O225250275300325單位面積TR/?O0.0640.0710.0780.0860.092辦公建筑室內(nèi)溫度、濕度的設(shè)計參數(shù)及允許噪聲辦公建筑室內(nèi)溫度、濕度的設(shè)計參數(shù)及允許噪聲夏季冬季噪聲標(biāo)準(zhǔn)(A聲類別NC數(shù)級)dB(A)溫度(℃)相對濕度溫度(℃)相對濕度一般辦公室26-28<65%18-20不作規(guī)定40-5540-50高級辦公室24-27<60%20-22≥35%30-4025-35會議接待室25-27<65%16-18不作規(guī)定40-5035-45電話總機(jī)房25-27<65%16-18不作規(guī)定55-6050-55計算機(jī)房24-28≤60%18-20不作規(guī)定55-6550-60復(fù)印機(jī)房24-28≤55%18-20不作規(guī)定55-6050-55依人數(shù)計算各場所每小時換氣次數(shù)換量場所種類次種類次數(shù)換氣量場所換氣對象數(shù)廚房15觀覽室12m3/min寢室戲院放映室20男人1.416一般家庭客廳6等候室10婦女1.16廁所10診療室6小孩0.75浴室病院手術(shù)室15牛馬3.838餐廳10消毒室12廚房15一般作業(yè)室6旅館及大飯店大食堂工場涂裝室208廁所10事務(wù)室6浴室一般建筑128會議室飲食室6沖洗片室10飲食店廚房暗室20宴會室10公共廁所20文案大全實用標(biāo)準(zhǔn)禮堂6體育館8學(xué)校12有害氣體塵埃發(fā)出地方20以上廁所教室6說明:房間通風(fēng)量=房間容積*換氣次數(shù)空氣調(diào)節(jié)房間的換氣次數(shù) ,應(yīng)符合下列規(guī)定:一、舒適性空氣調(diào)節(jié),每小時不宜小于5次,但高大房間應(yīng)按其冷負(fù)荷通過計算確定;民用建筑最小新風(fēng)量每人最小新 吸煙情房間名稱風(fēng)量 況影劇院、博物院、體育館、 8 無文案大全實用標(biāo)準(zhǔn)商店辦公室,圖書館、會議室,37無餐廳旅館客房30少量注:旅館客房等的衛(wèi)生間,當(dāng)其排風(fēng)量大于按本表所確定的數(shù)值時,則新風(fēng)量應(yīng)按排風(fēng)量采用。二、工藝性空氣調(diào)節(jié) ,不宜小于表所列的數(shù)值 .換氣次數(shù)室溫允許被動每小時換氣次注范圍(oC)數(shù)±1.05高大房間除外±0.58±0.1~0.212工作時間不送風(fēng)的除外一般建筑中常用風(fēng)道的風(fēng)速 (風(fēng)管和設(shè)備內(nèi)的風(fēng)速)位置 推薦值(m/s) 最大值(m/s)公共建筑 工廠 住宅 公共建筑 工廠 住宅風(fēng)機(jī)吸入 4.0 5.0 3.5 5.0 7.0 4.5口文案大全實用標(biāo)準(zhǔn)風(fēng)機(jī)出口6.5~108~125~87.5~118.5~148.5干管5~6.56~93.5~4.55.5~86.5~114~6支管3~4.54~534~6.55~93.5~5支管上接3~3.542.54~65~83.25~出的風(fēng)管4中央空調(diào)中常用風(fēng)速風(fēng)管類別風(fēng)速(m/s)風(fēng)機(jī)附近的極限自然通風(fēng)機(jī)械通風(fēng)風(fēng)速吸入空氣的百頁0~1.02~4窗吸風(fēng)管1~22~6支管和垂直風(fēng)管0.5~1.52~510~12水平總風(fēng)管0.5~1.05~8接近地面的進(jìn)風(fēng)0.2~0.50.2~0.5口接近頂棚的進(jìn)風(fēng)0.5~1.01~2口接近頂棚的排風(fēng)0.5~1.01~2口推薦的送風(fēng)機(jī)的靜壓值種類風(fēng)機(jī)靜壓值(pa)通風(fēng)設(shè)備小型系統(tǒng)100~250一般300~400小型(空調(diào)面積300㎡以400~500內(nèi))中型(空調(diào)面積2000㎡以600~750空調(diào)裝置內(nèi))大型(空調(diào)面積大于2000650~1100㎡)高速系統(tǒng)(中型)1000~1500高速系統(tǒng)(大型)1500~2500高速風(fēng)管的容許風(fēng)速 (m/s)風(fēng)量(m/h)㎡最大容許風(fēng)速(m/s)5000~1000012.510000~1700017.5文案大全實用標(biāo)準(zhǔn)17000~25000 20.025000~40000 22.540000~70000 25.070000~100000 30.0送風(fēng)口的送風(fēng)速度側(cè)送百葉風(fēng)口的最大送風(fēng)速度 (m/s)建筑性質(zhì)最大送風(fēng)速度建筑性質(zhì)最大送風(fēng)速度播音室1.5-2.5個人辦公室2.5-5.0住宅2.5-3.8一般辦公室5.0-6.3旅館客房2.5-3.8電影院5.0-6.3劇場2.5-3.8百貨公司7.5會堂2.5-3.8回風(fēng)口的吸風(fēng)風(fēng)速(m/s)回風(fēng)口的位置吸風(fēng)風(fēng)速房間的上部4-5房間的下部靠近經(jīng)常有人活動的地方1.5-2靠近不經(jīng)常有人活動的地方3-4走道回風(fēng)1-1.5注:對一般地通風(fēng)系統(tǒng),風(fēng)管的阻力損失值△ P(Pa)可按下式計算:△P=Pm*L(1+k)Pm:單位長度風(fēng)管的摩擦阻力,一般 0.8-1.5Pa/m。送回風(fēng)管總長度文案大全實用標(biāo)準(zhǔn)局部壓力損失與摩擦壓力損失的比值,彎頭、三通少時,取K=1.0-2.0;彎頭、三通較多時,取 K=3.0-5.0。廚房空調(diào)與通風(fēng)的設(shè)計一.廚房中產(chǎn)生油煙的設(shè)備應(yīng)加設(shè)有機(jī)械排風(fēng)和油煙過濾器的排氣罩;產(chǎn)生大量蒸汽的設(shè)備應(yīng)安置在隔開的小間內(nèi),并在其上部設(shè)機(jī)械排風(fēng)的排氣罩。排氣罩設(shè)計應(yīng)遵守以下原則:(1)排氣罩的平面尺寸一般應(yīng)比爐灶邊大出100mm左右。排氣罩的下沿距爐灶面的距離應(yīng)盡可能減小,一般不宜大于1.0m。罩口下沿四周應(yīng)設(shè)置集油集水溝槽,溝槽底部應(yīng)裝排油污管子。2)排油煙的排氣罩內(nèi)應(yīng)設(shè)油煙過濾器,過濾器應(yīng)便于清洗和更換或采用自動清洗的運(yùn)水煙罩等除油設(shè)施。(3)排氣罩宜采用不銹鋼板或鍍鋅板制作,厚度一般以 1.0-2.0mm為宜。二.排氣罩最小排

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論