涪陵新妙·適園華府工字鋼懸挑雙排腳手架施工專項方案建設(shè)單位:重慶亮翼地產(chǎn)有限公司編制單位:四川宜爾建筑工程有限公司編制日期:二0一七年二月十七日目錄一、編制依據(jù)·············································2二、工程概況·············································2三、總體籌劃及施工部署···································31、總體籌劃··········································32、安全領(lǐng)導(dǎo)小組······································5四、搭設(shè)流程及施工工藝···································6五、材料選擇及構(gòu)造要求···································12六、勞動力安排···········································13七、腳手架檢查與驗收·····································141、構(gòu)配件檢查與驗收··································152、腳手架檢查與驗收··································16八、腳手架施工安全保證措施·······························171、組織保障··········································182、技術(shù)措施··········································203、監(jiān)測監(jiān)控··········································21九、應(yīng)急預(yù)案·············································22十、2.95m層高型鋼懸挑腳手架計算書·························24工字鋼懸挑腳手架專項施工方案一、編制依據(jù)1、涪陵新妙·適園華府(住宅1、2、3#樓)施工圖;2、涪陵新妙·適園華府(住宅1、2、3#樓)施工組織設(shè)計;3、各類參考規(guī)范及書籍:《建設(shè)工程安全生產(chǎn)管理條例》《重慶市建筑管理條例》《建筑施工安全檢查標(biāo)準(zhǔn)》(JGJ59—2011)《建筑施工高處作業(yè)安全技術(shù)規(guī)范》(JGJ80—2016)《建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范》(JGJ130—2011)《建筑工程預(yù)防高處墜落事故若干規(guī)定》《重慶市建筑工地文明施工標(biāo)準(zhǔn)》《建筑施工計算手冊》江正榮著中國建筑工業(yè)出版社《鋼結(jié)構(gòu)設(shè)計規(guī)范》(GB50017-2014)中國建筑工業(yè)出版社《建筑結(jié)構(gòu)荷載規(guī)范》(GB50009-2012)中國建筑工業(yè)出版社涪陵新妙·適園華府設(shè)計文件二、工程概況工程名稱:涪陵新妙·適園華府(住宅1、2、3#樓)工程地點:涪陵新妙鎮(zhèn)適園一社建設(shè)單位:重慶亮翼地產(chǎn)有限公司設(shè)計單位:重慶海邁建筑工程設(shè)計有限公司監(jiān)理單位:重慶華大建筑工程監(jiān)理有限公司施工單位:四川宜爾建筑工程有限公司本工程名稱為涪陵新妙·適園華府由高層及商業(yè)組成,工程地點為重慶市涪陵區(qū)新妙鎮(zhèn)適園一社,由重慶亮翼地產(chǎn)有限公司投資開發(fā)建設(shè),建筑面積約為55710.49m2,分別為3棟住宅(1、2、3#樓)地上18層地下2層和5棟商業(yè)(D1、D2、D3、D4、D5),建筑高度59米、層高2.95米?;A(chǔ)設(shè)計高層為人工挖孔樁及商業(yè)為獨(dú)立基礎(chǔ);主體結(jié)構(gòu)設(shè)計形式為剪力墻結(jié)構(gòu)。本工程建筑結(jié)構(gòu)的安全等級為二級,抗震設(shè)防烈度為6度。三、總體籌劃及施工部署(一)、總體籌劃本工程考慮到施工工期、質(zhì)量、安全和合同要求,故在選擇方案時,應(yīng)充分考慮以下幾點:1、架體的結(jié)構(gòu)設(shè)計,力求做到結(jié)構(gòu)要安全可靠,造價經(jīng)濟(jì)合理。2、在規(guī)定的條件下和規(guī)定的使用期限內(nèi),能夠充分滿足預(yù)期的安全性和耐久性。3、選用材料時,力求做到常見通用、可周轉(zhuǎn)利用,便于保養(yǎng)維修。4、結(jié)構(gòu)選型時,力求做到受力明確,構(gòu)造措施到位,升降搭拆方便,便于檢查驗收;5、綜合以上幾點,腳手架的搭設(shè),還必須符合JCJ59-2011等檢查標(biāo)準(zhǔn)要求,要符合相關(guān)文明標(biāo)化工地的有關(guān)標(biāo)準(zhǔn)。6、結(jié)合以上腳手架設(shè)計原則,同時結(jié)合本工程的實際情況,綜合考慮了以往的施工經(jīng)驗,決定采用工字鋼懸挑腳手架分多段樓層懸挑工字鋼:1、2、3#樓:8層、14層7、在懸挑腳手架計算時,第一段懸挑層(8層樓面~14層樓面)懸挑高度為17.70m,作為計算參考依據(jù)。(二)、安全領(lǐng)導(dǎo)小組搭設(shè)過程中,因處在施工高峰期,各施工班組在交叉作業(yè)中,故應(yīng)加強(qiáng)安全監(jiān)控力度,現(xiàn)場設(shè)定若干名安全監(jiān)控員。水平和垂直材料運(yùn)輸必須設(shè)置臨時警戒區(qū)域,用紅白三角小旗圍欄。謹(jǐn)防非施工人員進(jìn)入。同時成立以項目經(jīng)理為組長的安全領(lǐng)導(dǎo)小組以加強(qiáng)現(xiàn)場安全防護(hù)工作,本小組機(jī)構(gòu)組成、人員編制及責(zé)任分工如下:唐天通(項目經(jīng)理)——組長,負(fù)責(zé)協(xié)調(diào)指揮工作;楊睿(技術(shù)負(fù)責(zé)人)——副組長,負(fù)責(zé)現(xiàn)場施工指揮,技術(shù)交底;陳晨(施工員)——組員,負(fù)責(zé)現(xiàn)場施工指揮;張濤(施工員)——組員,負(fù)責(zé)現(xiàn)場施工指揮;劉芳(安全員)——組員,負(fù)責(zé)現(xiàn)場安全檢查工作;吳亞軍(架子工班長)——組員,負(fù)責(zé)現(xiàn)場具體施工;搭設(shè)流程及施工工藝懸挑腳手架平面布置圖普通型鋼懸挑腳手架工藝流程施工準(zhǔn)備→放線定位→預(yù)埋Ф16直徑U型鋼筋拉環(huán)→懸挑架的支承結(jié)構(gòu)安裝→豎立桿→將縱向掃地桿與立桿扣接→安裝橫向掃地桿→安裝縱向水平桿→安裝橫向水平桿→安裝連墻件→安裝剪刀撐→掛安全網(wǎng)→作業(yè)層鋪腳手板和擋腳板。搭設(shè)參數(shù)表:腳手架排數(shù)雙排大小橫桿布置小橫桿在上搭設(shè)高度(m)17.7立桿型號Φ48×3.5立桿縱距(m)1.5立桿橫距(m)0.7內(nèi)排架距離墻長度0.4連墻件布置方式二步三跨立桿步距(m)1.45錨固長度(m)3.3型鋼懸挑長度(m)1.2施工均布荷載(kN/m2)3鋼絲繩支撐道數(shù)1腳手板鋪設(shè)層數(shù)2同時施工層數(shù)2基本風(fēng)壓(kN/m2)0.451、型鋼水平懸挑梁(1)型鋼水平懸挑梁必須保證有足夠的錨固強(qiáng)度和截面抗屈曲能力,型鋼水平懸挑梁的縱向間距與上部腳手架立桿的縱向間距相同,立桿直接支承在懸挑梁上。上部腳手架立桿與挑梁支承結(jié)構(gòu)應(yīng)有可靠固定的定位點(采用焊接豎向鋼筋),以確保上部架體的穩(wěn)定,立桿定位點離懸挑梁端部100mm。采用在型鋼上焊接150-200mm、直徑φ20mm的鋼筋固定柱,立桿套座其外,并同時在立桿下部設(shè)置掃地桿。(2)型鋼水平懸挑梁宜采用雙軸對稱截面的型鋼。懸挑鋼梁型號及錨固件應(yīng)按設(shè)計確定,鋼梁截面高度為160mm。懸挑梁尾端應(yīng)在兩處及以上固定于鋼筋混凝土梁板結(jié)構(gòu)上。錨固型鋼懸挑梁的U型鋼筋拉環(huán)或錨固螺栓直徑為16㎜HPB235級鋼筋。用于錨固的U型鋼筋拉環(huán)或螺栓應(yīng)采用冷彎成型。U型鋼筋拉環(huán)、錨固螺栓與型鋼間隙應(yīng)用鋼楔或硬木楔楔緊。型鋼懸挑梁外端設(shè)置鋼絲繩與上一層建筑結(jié)構(gòu)斜拉結(jié)。鋼絲繩不參與懸挑鋼梁受力計算;鋼絲繩與建筑結(jié)構(gòu)拉結(jié)的吊環(huán)應(yīng)使用HPB235級鋼筋,其直徑為16㎜,吊環(huán)預(yù)埋錨固長度應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《混凝土結(jié)構(gòu)設(shè)計規(guī)范》GB50010中鋼筋錨固的規(guī)定。(3)懸挑鋼梁懸挑長度應(yīng)按設(shè)計確定,固定段長度不應(yīng)小于懸挑段長度的1.25倍。型鋼懸挑梁固定端應(yīng)采用2個(對)及以上U型鋼筋拉環(huán)或錨固螺栓與建筑結(jié)構(gòu)梁板固定,U型鋼筋拉環(huán)或錨固螺栓應(yīng)預(yù)埋至混凝土梁、板底層鋼筋位置,并應(yīng)與混凝土梁、板底層鋼筋焊接或綁扎牢固,其錨固長度應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《混凝土結(jié)構(gòu)設(shè)計規(guī)范》GB50010中鋼筋錨固的規(guī)定。型鋼懸挑腳手架構(gòu)造圖懸挑鋼梁U型螺栓固定構(gòu)造圖懸挑鋼梁穿墻構(gòu)造圖1——木楔楔緊懸挑鋼梁樓面構(gòu)造圖2、立桿(1)腳手架立桿采用對接接長,立桿的對接扣件應(yīng)交錯布置,兩根相鄰立桿的接頭不應(yīng)設(shè)置在同步內(nèi),同步內(nèi)隔一根立桿的兩個相隔接頭在高度方向錯開的距離不宜小于500㎜;各接頭中心至主節(jié)點的距離不宜大于步距的1/3。(2)腳手架立桿頂端欄桿宜高出女兒墻上端1m,宜高出檐口上端1.5m。3、腳手架縱向水平桿、橫向水平桿、腳手板(1)縱向水平桿的構(gòu)造應(yīng)符合下列規(guī)定:1、縱向水平桿應(yīng)設(shè)置在立桿內(nèi)側(cè),單根桿長度不應(yīng)小于3跨;2、縱向水平桿接長應(yīng)采用對接扣件連接或搭接,并應(yīng)符合下列規(guī)定:1)兩根相鄰縱向水平桿的接頭不應(yīng)設(shè)置在同步或同跨內(nèi);不同步或不同跨兩個相鄰接頭在水平方向錯開的距離不應(yīng)小于500mm;各接頭中心至最近主節(jié)點的距離不應(yīng)大于縱距的1/3(見下圖)(a)接頭不在同步內(nèi)(立面)(b)接頭不在同跨內(nèi)(平面)縱向水平桿對接接頭布置1——立桿;2——縱向水平桿;3——橫向水平桿2)搭接長度不應(yīng)小于1m,應(yīng)等間距設(shè)置3個旋轉(zhuǎn)扣件固定;端部扣件蓋板邊緣至搭接縱向水平桿桿端的距離不應(yīng)小于100mm。3、使用竹串片腳手板時,縱向水平桿應(yīng)作為橫向水平桿的支座,用直角扣件固定在立桿上。鋪竹串片腳手板時縱向水平桿的構(gòu)造1——立桿;2——縱向水平桿;3——橫向水平桿;4——竹串片腳手板;5——其它腳手板(2)橫向水平桿的構(gòu)造應(yīng)符合下列規(guī)定:1、作業(yè)層上非主節(jié)點處的橫向水平桿,宜根據(jù)支承腳手板的需要等間距設(shè)置,最大間距不應(yīng)大于縱距的1/2;2、使用竹串片腳手板時,雙排腳手架的橫向水平桿兩端均應(yīng)采用直角扣件固定在縱向水平桿上。(三)主節(jié)點處必須設(shè)置一根橫向水平桿,用直角扣件扣接且嚴(yán)禁拆除。(四)腳手板的設(shè)置應(yīng)符合下列規(guī)定:1、作業(yè)層腳手板應(yīng)鋪滿、鋪穩(wěn)、鋪實;2、竹串片腳手板應(yīng)設(shè)置在三根橫向水平桿上。腳手板的鋪設(shè)應(yīng)采用對接平鋪或搭接鋪設(shè)。腳手板對接平鋪時,接頭處應(yīng)設(shè)兩根橫向水平桿,腳手板外伸長度應(yīng)取130mm~150mm,兩塊腳手板外伸長度的和不應(yīng)大于300mm(圖a);腳手板搭接鋪設(shè)時,接頭應(yīng)支在橫向水平桿上,搭接長度不應(yīng)小于200mm,其伸出橫向水平桿的長度不應(yīng)小于100mm(圖b)。(a)腳手板對接(b)腳手板搭接腳手板對接、搭接構(gòu)造3、作業(yè)層端部腳手板探頭長度應(yīng)取150mm,其板的兩端均應(yīng)固定于支承桿件上。4、剪刀撐(一)懸挑腳手架應(yīng)在外側(cè)全立面連續(xù)設(shè)置剪刀撐。(二)剪刀撐的設(shè)置應(yīng)符合下列規(guī)定:1、每道剪刀撐跨越立桿的根數(shù)不小于4跨,且不小于6m,斜桿與地面的傾角應(yīng)在450~600之間;剪刀撐跨越立桿的最多根數(shù)剪刀撐斜桿與地面的傾角a450500600剪刀撐跨越立桿的最多根數(shù)n7652、剪刀撐斜桿的接長應(yīng)采用搭接,搭接長度不小于1m,并采用不少于2個旋轉(zhuǎn)扣件固定。端部扣件蓋板的邊緣至桿端距離不小于100mm。3、剪刀撐斜桿應(yīng)用旋轉(zhuǎn)扣件固定在與之相交的橫向水平桿的伸出端或立桿上,旋轉(zhuǎn)扣件中心線至主節(jié)點的距離不應(yīng)大于150mm。剪刀撐布置圖5、連墻件(一)腳手架連墻件設(shè)置的位置、數(shù)量應(yīng)按專項施工方案確定。(二)連墻件的布置應(yīng)符合下列規(guī)定:1、應(yīng)靠近主節(jié)點設(shè)置,偏離主節(jié)點的距離不應(yīng)大于300mm;2、應(yīng)從底層第一步縱向水平桿處開始設(shè)置,當(dāng)該處設(shè)置有困難時,應(yīng)采用其它可靠措施固定;3、應(yīng)優(yōu)先采用菱形布置,或采用方形、矩形布置。(三)連墻件中的連墻桿應(yīng)呈水平設(shè)置,當(dāng)不能水平設(shè)置時,應(yīng)向腳手架一端下斜連接。(四)連墻件必須采用可承受拉力和壓力的構(gòu)造,采用剛性連墻件與建筑物連接。6、防護(hù)欄桿(1)腳手架外側(cè)使用建設(shè)主管部門認(rèn)證的質(zhì)量合格綠色密目式安全網(wǎng)封閉,且將安全網(wǎng)固定在腳手架外立桿里側(cè)。(2)選用18#鉛絲張掛安全網(wǎng),要求嚴(yán)密、平整。(3)腳手架外側(cè)必須設(shè)1.2m高的防護(hù)欄桿和30cm高踢腳桿,頂排防護(hù)欄桿不少于2道,高度分別為0.9m和1.3m。(4)腳手架內(nèi)側(cè)形成臨邊的(如遇大開間門窗洞等),在腳手架內(nèi)側(cè)設(shè)1.2m的防護(hù)欄桿和30cm高踢腳桿。五、材料選擇及構(gòu)造要求l、腳手架鋼材強(qiáng)度等級Q235-A,鋼管表面應(yīng)平直光滑,不應(yīng)有裂紋、分層、壓痕、劃道和硬彎,新用的鋼管要有出廠合格證。腳手架施工前必須將入場鋼管取樣,送有相關(guān)國家資質(zhì)的試驗單位,進(jìn)行鋼管抗彎、抗拉等力學(xué)試驗,試驗結(jié)果滿足設(shè)計要求后,方可在施工中使用。2、本工程鋼管腳手架的搭設(shè)使用可鍛鑄造扣件,應(yīng)符合建設(shè)部《鋼管腳手扣件標(biāo)準(zhǔn)》JGJ22-85的要求,由有扣件生產(chǎn)許可證的生產(chǎn)廠家提供,不得有裂紋、氣孔、縮松、砂眼等鍛造缺陷,扣件的規(guī)格應(yīng)與鋼管相匹配,貼和面應(yīng)平整,活動部位靈活,夾緊鋼管時開口處最小距離不小于5mm。鋼管螺栓擰緊力矩達(dá)65N.m時不得破壞。如使用舊扣件時,扣件必須取樣送有相關(guān)國家資質(zhì)的試驗單位,進(jìn)行扣件抗滑力等試驗,試驗結(jié)果滿足設(shè)計要求后方可在施工中使用。3、搭設(shè)架子前應(yīng)進(jìn)行保養(yǎng),除銹并統(tǒng)一涂色,顏色力求環(huán)境美觀。腳手架立桿、橫桿、防護(hù)欄桿、踢腳桿統(tǒng)一漆黃色,剪力撐統(tǒng)一漆藍(lán)色,懸挑工字鋼統(tǒng)一柒紅色。4、腳手板符合有關(guān)要求。5、安全網(wǎng)采用密目式安全網(wǎng),網(wǎng)目應(yīng)滿足2000目/100cm2,做耐貫穿試驗不穿透,6×1.8m的單張網(wǎng)顏色應(yīng)滿足環(huán)境效果要求,選用綠色。要求阻燃,使用的安全網(wǎng)必須有產(chǎn)品生產(chǎn)許可證和質(zhì)量合格證,以及由相關(guān)建筑安全監(jiān)督管理部門發(fā)放的準(zhǔn)用證。6、連墻件材料采用鋼管,其材質(zhì)應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《碳素鋼結(jié)構(gòu)》(GB700-88)中Q235A鋼的要求。普通型鋼懸挑腳手架水平懸挑梁是此類型腳手架的重要材料,其鋼材強(qiáng)度等級為Q235-A,型號見材料表,懸挑腳手架用型鋼的材質(zhì)應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《碳素結(jié)構(gòu)鋼》GB/T700或《低合金高強(qiáng)度結(jié)構(gòu)鋼》GB/T1591的規(guī)定,用于固定型鋼懸挑梁的U型鋼筋拉環(huán)或錨固螺栓材質(zhì)應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《鋼筋混凝土用鋼第1部分:熱軋光圓鋼筋》GB1499.1中HPB235級鋼筋的規(guī)定。搭設(shè)腳手架的鋼管鋼材強(qiáng)度等級為Q235-A,鋼管表面應(yīng)平直光滑,不應(yīng)有裂紋、分層、壓痕、劃道和硬彎,新用的鋼管要有出廠合格證。腳手架施工前必須將入場鋼管取樣,送有相關(guān)國家資質(zhì)的試驗單位,進(jìn)行鋼管抗彎、抗拉等力學(xué)試驗,試CC驗結(jié)果滿足設(shè)計要求后,方可在施工中使用??奂榭慑戣T造扣件,應(yīng)符合《鋼管腳手扣件標(biāo)準(zhǔn)》GB15831-2006的要求,由有扣件生產(chǎn)許可證的生產(chǎn)廠家提供,不得有裂紋、氣孔、縮松、砂眼等鍛造缺陷,扣件的規(guī)格應(yīng)與鋼管相匹配,貼和面應(yīng)平整,活動部位靈活,夾緊鋼管時開口處最小距離不小于5mm。鋼管螺栓擰緊力矩達(dá)65N.m時不得破壞。如使用舊扣件時,扣件必須取樣送有相關(guān)國家資質(zhì)的試驗單位,進(jìn)行扣件抗滑力等試驗,試驗結(jié)果滿足設(shè)計要求后方可在施工中使用。主要材料參數(shù)表:材料名稱普通型鋼懸挑腳手架鋼管Φ48×3.5扣件配套水平懸挑梁16號工字鋼梁支撐拉繩(鋼絲繩型號):Φ16腳手扳竹串片腳手板安全網(wǎng)密目安全網(wǎng)六、勞動力安排1、為確保工程進(jìn)度的需要,同時根據(jù)本工程的結(jié)構(gòu)特征和外腳手架的工程量,確定本工程外腳手架搭設(shè)按下表配置人力資源,操作工均有上崗作業(yè)證書。2、建立由項目經(jīng)理、施工員、安全員、搭設(shè)負(fù)責(zé)人組成的管理機(jī)構(gòu),搭設(shè)負(fù)責(zé)人負(fù)有指揮、調(diào)配、檢查的直接責(zé)任。3、外腳手架的搭設(shè)和拆除,均應(yīng)有項目技術(shù)負(fù)責(zé)人的認(rèn)可,方可進(jìn)行施工作業(yè),并必須配備有足夠的輔助人員和必要的工具。(一)、勞動力安排表工種人數(shù)技術(shù)管理2安全監(jiān)督2質(zhì)量檢查1架子工20(二)、機(jī)具配備機(jī)具名稱數(shù)量備注架子扳手20把架子工搭設(shè)和拆除架子用力矩扳手10把檢查架子扣件擰緊力度是否達(dá)到要求倒鏈10把調(diào)整架子水平彎曲度七、腳手架檢查與驗收一、構(gòu)配件檢查與驗收(一)新鋼管的檢查應(yīng)符合下列規(guī)定:1、應(yīng)有產(chǎn)品質(zhì)量合格證;2、應(yīng)有質(zhì)量檢驗報告,鋼管材質(zhì)檢驗方法應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《金屬材料室溫拉伸試驗方法》GB/T228的有關(guān)規(guī)定,其質(zhì)量應(yīng)符合規(guī)范規(guī)定;3、鋼管表面應(yīng)平直光滑,不應(yīng)有裂縫、結(jié)疤、分層、錯位、硬彎、毛刺、壓痕和深的劃道;4、鋼管外徑、壁厚、端面等的偏差,應(yīng)分別符合規(guī)范規(guī)定;5、鋼管應(yīng)涂有防銹漆。(二)舊鋼管的檢查應(yīng)符合下列規(guī)定:1、表面銹蝕深度應(yīng)符合規(guī)范規(guī)定。銹蝕檢查應(yīng)每年一次。檢查時,應(yīng)在銹蝕嚴(yán)重的鋼管中抽取三根,在每根銹蝕嚴(yán)重的部位橫向截斷取樣檢查,當(dāng)銹蝕深度超過規(guī)定值時不得使用;2、鋼管彎曲變形應(yīng)符合規(guī)范規(guī)定。(三)扣件驗收應(yīng)符合下列規(guī)定:1、扣件應(yīng)有生產(chǎn)許可證、法定檢測單位的測試報告和產(chǎn)品質(zhì)量合格證。當(dāng)對扣件質(zhì)量有懷疑時,應(yīng)按現(xiàn)行國家標(biāo)準(zhǔn)《鋼管腳手架扣件》GB15831的規(guī)定抽樣檢測;2、新、舊扣件均應(yīng)進(jìn)行防銹處理;3、扣件的技術(shù)要求應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《鋼管腳手架扣件》GB15831的相關(guān)規(guī)定。(四)扣件進(jìn)入施工現(xiàn)場應(yīng)檢查產(chǎn)品合格證,并應(yīng)進(jìn)行抽樣復(fù)試,技術(shù)性能應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《鋼管腳手架扣件》GB15831的規(guī)定??奂谑褂们皯?yīng)逐個挑選,有裂縫、變形、螺栓出現(xiàn)滑絲的嚴(yán)禁使用。(五)竹串片腳手板的材料應(yīng)符合規(guī)范規(guī)定。(六)懸挑腳手架用型鋼的質(zhì)量應(yīng)符合規(guī)范規(guī)定,并應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《鋼結(jié)構(gòu)工程施工質(zhì)量驗收規(guī)范》GB50205的有關(guān)規(guī)定。(七)可調(diào)托撐的檢查應(yīng)符合下列規(guī)定:1應(yīng)有產(chǎn)品質(zhì)量合格證,其質(zhì)量應(yīng)符合規(guī)范規(guī)定;2應(yīng)有質(zhì)量檢驗報告,可調(diào)托撐抗壓承載力應(yīng)符合規(guī)范規(guī)定;3可調(diào)托撐支托板厚不應(yīng)小于5毫米,變形不應(yīng)大于1mm;4嚴(yán)禁使用有裂縫的支托板、螺母。構(gòu)配件允許偏差應(yīng)符合規(guī)范規(guī)定。對于構(gòu)配件由項目部專職安全員負(fù)責(zé)日常檢查,通知資料員送檢。二、腳手架檢查與驗收(一)腳手架及其地基基礎(chǔ)應(yīng)在下列階段進(jìn)行檢查與驗收:1、基礎(chǔ)完工后及腳手架搭設(shè)前;2、作業(yè)層上施加荷載前;3、每搭設(shè)完6m~8m高度后;4、達(dá)到設(shè)計高度后;5、遇有六級強(qiáng)風(fēng)及以上風(fēng)或大雨后,凍結(jié)地區(qū)解凍后;6、停用超過一個月。(二)應(yīng)根據(jù)下列技術(shù)文件進(jìn)行腳手架檢查、驗收:1、規(guī)范相關(guān)規(guī)定;2、專項施工方案及變更文件;3、技術(shù)交底文件;4、構(gòu)配件質(zhì)量檢查表。(三)腳手架使用中,應(yīng)定期檢查下列要求內(nèi)容:1、桿件的設(shè)置和連接,連墻件、支撐等的構(gòu)造應(yīng)符合規(guī)范和專項施工方案的要求;2、底座應(yīng)無松動,立桿應(yīng)無懸空;3、扣件螺栓應(yīng)無松動;4、立桿的沉降與垂直度的偏差應(yīng)符合規(guī)范規(guī)定;5、安全防護(hù)措施應(yīng)符合規(guī)范要求;6、應(yīng)無超載使用。(四)腳手架搭設(shè)的技術(shù)要求、允許偏差與檢驗方法,應(yīng)符合規(guī)范規(guī)定。(五)安裝后的扣件螺栓擰緊扭力矩應(yīng)采用扭力板手檢查,抽樣方法應(yīng)按隨機(jī)分布原則進(jìn)行。抽樣檢查數(shù)目與質(zhì)量判定標(biāo)準(zhǔn),應(yīng)按規(guī)定確定。不合格的應(yīng)重新擰緊至合格。(六)對于架體驗收項目部技術(shù)負(fù)責(zé)人、安全員、施工員、質(zhì)檢員、勞務(wù)負(fù)責(zé)人一起對搭設(shè)好的架體進(jìn)行驗收形成書面驗收記錄。對于存在的問題下發(fā)質(zhì)量整改書,安全員負(fù)責(zé)整改回復(fù)及監(jiān)督落實情況并將驗收情況報送監(jiān)理單位。八、腳手架施工安全保證措施一、組織保障1、安全保證體系2、環(huán)境保護(hù)體系二、技術(shù)措施腳手架搭設(shè)技術(shù)措施1、鋼管架應(yīng)設(shè)置避雷針,分置于主樓外架四角立桿之上,并聯(lián)通大橫桿,形成避雷網(wǎng)絡(luò),并檢測接地電阻不大于30Ω。2、外腳手架不得搭設(shè)在距離外架空線路的安全距離內(nèi),并做好可靠的安全接地處理。3、定期檢查腳手架,發(fā)現(xiàn)問題和隱患,在施工作業(yè)前及時維修加固,以達(dá)到堅固穩(wěn)定,確保施工安全。4、外腳手架嚴(yán)禁鋼竹、鋼木混搭,禁止扣件、繩索、鐵絲、竹篾、塑料篾混用。5、外腳手架搭設(shè)人員必須持證上崗,并正確使用安全帽、安全帶、穿防滑鞋。6、嚴(yán)禁腳手板存在探頭板,鋪設(shè)腳手板以及多層作業(yè)時,應(yīng)盡量使施工荷載內(nèi)、外傳遞平衡。7、保證腳手架體的整體性,不得與井架、升降機(jī)一并拉結(jié),不得截斷架體。8、結(jié)構(gòu)外腳手架每支搭一層,支搭完畢后,經(jīng)項目部安全員驗收合格后方可使用。任何班組長和個人,未經(jīng)同意不得任意拆除腳手架部件。9、嚴(yán)格控制施工荷載,腳手板不得集中堆料施荷,施工荷載不得大于3kN/m2,確保較大安全儲備。10、結(jié)構(gòu)施工時不允許多層同時作業(yè),裝修施工時同時作業(yè)層數(shù)不超過兩層,臨時性用的懸挑架的同時作業(yè)層數(shù)不超過兩層。11、當(dāng)作業(yè)層高出其下連墻件2.9m以上、且其上尚無連墻件時,應(yīng)采取適當(dāng)?shù)呐R時撐拉措施。12、各作業(yè)層之間設(shè)置可靠的防護(hù)柵欄,防止墜落物體傷人。腳手架拆除技術(shù)措施1、拆架前:(1)應(yīng)全面檢查腳手架的扣件連接、連墻件、支撐體系等是否符合構(gòu)造要求;

(2)應(yīng)根據(jù)檢查結(jié)果補(bǔ)充完善施工組織設(shè)計中的拆除順序和措施,經(jīng)主管部門批準(zhǔn)后方可實施;(3)應(yīng)由單位工程負(fù)責(zé)人進(jìn)行拆除安全技術(shù)交底;

(4)應(yīng)清除腳手架上雜物及地面障礙物。2、拆架時應(yīng)劃分作業(yè)區(qū),周圍設(shè)繩綁圍欄或豎立警戒標(biāo)志,地面應(yīng)設(shè)專人指揮,禁止非作業(yè)人員進(jìn)入,項目部安全員必須進(jìn)行過程監(jiān)督防止發(fā)生意外。當(dāng)腳手架采取分段、分立面拆除時,對不拆除的腳手架兩端,應(yīng)先按《建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范》的規(guī)定設(shè)置連墻件和橫向斜撐加固。3、拆架的高處作業(yè)人員應(yīng)戴安全帽、系安全帶、扎裹腿、穿軟底防滑鞋。4、拆架程序應(yīng)遵守“由上而下,先搭后拆”的原則,即先拆拉桿、腳手板、剪刀撐、斜撐,而后拆小橫桿、大橫桿、立桿等,并按“一步一清”原則依次進(jìn)行。嚴(yán)禁上下同時進(jìn)行拆架作業(yè)。5、拆立桿時,要先抱住立桿再拆開最后兩個扣件,拆除大橫桿、斜撐、剪刀撐時,應(yīng)先拆除中間扣件,然后托住中間,再解端頭扣件。6、連墻件必須隨腳手架逐層拆除,嚴(yán)禁先將連墻件整層或數(shù)層拆除后再拆腳手架;分段拆除高差不應(yīng)大于2步,如高差大于2步,應(yīng)增設(shè)連墻件加固;當(dāng)腳手架拆至下部最后一根長立桿的高度(約6.5m)時,應(yīng)先在適當(dāng)位置搭設(shè)臨時拋撐加固后,再拆除連墻件。7、拆除時要統(tǒng)一指揮,上下呼應(yīng),動作協(xié)調(diào),當(dāng)解開與另一人有關(guān)的結(jié)扣時,應(yīng)先通知對方,以防墜落。8、拆架時嚴(yán)禁碰撞腳手架附近電源線,以防觸電事故。9、在拆架時,不得中途換人,如必須換人時,應(yīng)將拆除情況交代清楚后方可離開。10、拆下的材料要徐徐下運(yùn),嚴(yán)禁拋擲。運(yùn)至地面的材料應(yīng)按指定地點隨拆隨運(yùn),分類堆放,“當(dāng)天拆當(dāng)天清”,拆下的扣件和鐵絲要集中回收處理。11、高層建筑腳手架拆除,應(yīng)配備良好的通訊裝置。12、輸送至地面的桿件,應(yīng)及時按類堆放,整理保養(yǎng)。13、當(dāng)天離崗時,應(yīng)及時加固尚未拆除部分,防止存留隱患造成復(fù)崗后的人為事故。14、如遇強(qiáng)風(fēng)、大雨、雪等特殊氣候,不應(yīng)進(jìn)行腳手架的拆除,嚴(yán)禁夜間拆除。15、翻掀墊鋪竹笆應(yīng)注意站立位置,并應(yīng)自外向里翻起豎立,防止外翻將竹笆內(nèi)未清除的殘留物從高處墜落傷人。三、監(jiān)測監(jiān)控1、安全管理(1)搭設(shè)人員必須是經(jīng)過按現(xiàn)行國家標(biāo)準(zhǔn)《特種作業(yè)人員安全技術(shù)考核管理規(guī)則》GB5036考核合格的專業(yè)架子工。上崗人員定期體檢,合格者方可持證上崗;(2)搭設(shè)人員必須戴安全帽、系安全帶,穿防滑鞋;(3)腳手架的構(gòu)配件質(zhì)量與搭設(shè)質(zhì)量,應(yīng)按安全技術(shù)規(guī)范規(guī)定進(jìn)行檢查驗收,合格后方準(zhǔn)許使用;(4)作業(yè)層上的施工荷載應(yīng)符合設(shè)計要求,不得超載。不得將模板支架、攬風(fēng)繩、泵送混凝土和砂漿的輸送管等固定在腳手架上,嚴(yán)禁懸掛起重設(shè)備;(5)當(dāng)有六級以及六級以上大風(fēng)和霧、雨、雪天氣,應(yīng)停止腳手架的搭設(shè)與拆除作業(yè)。雪后架上作業(yè)應(yīng)有防滑措施,并掃除積雪;(6)腳手架的安全檢查與維護(hù),應(yīng)按安全技術(shù)規(guī)范進(jìn)行。安全網(wǎng)應(yīng)按規(guī)定搭設(shè)和拆除;(7)在腳手架使用期間,嚴(yán)禁拆除主節(jié)點處縱、橫水平桿、連墻件、交叉支撐、水平架、加固欄桿和欄桿;(8)不得在腳手架基礎(chǔ)及鄰近處進(jìn)行挖掘作業(yè),否則應(yīng)采取安全措施,并報主管部門批準(zhǔn);(9)臨街搭設(shè)腳手架時,外側(cè)應(yīng)有防止墜物傷人的防護(hù)措施;(10)在腳手架上進(jìn)行電、氣焊作業(yè)時,必須有防火措施和專人看守;(11)工地臨時用電線路的架設(shè)及腳手架接地、避雷措施等。應(yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)《施工現(xiàn)場臨時用電安全技術(shù)規(guī)范》JGJ46-2012的有關(guān)規(guī)定執(zhí)行;(12)搭拆腳手架時,地面應(yīng)設(shè)圍欄和警戒標(biāo)志,并派專人看守,嚴(yán)禁非操作人員入內(nèi)。2、日常維護(hù)管理要求(1)使用完畢的腳手架架料和構(gòu)件、零件要及時回收、分類整理,分類存放。堆放地點要場地平坦,排水良好,下設(shè)支墊,鋼管、角鋼、鋼桁架和其他鋼構(gòu)件最好放在室內(nèi),如果放在露天,應(yīng)用氈、席加蓋、扣件、螺栓及其他小零件,應(yīng)用木箱。鋼筋籠或麻袋、草包等容器分類貯存,放在室內(nèi);(2)彎曲的鋼管桿件要調(diào)直,損壞的構(gòu)件要修復(fù),損壞的扣件、零件要更換;(3)做好鋼鐵件的防銹和木制件的防腐處理,鋼管外壁在濕度較大地區(qū)(相對濕度大于75%),應(yīng)每年涂刷防銹漆一次;其他地區(qū)可兩年涂刷一次。涂刷時涂層不宜過厚。經(jīng)徹底除銹后,涂一度紅丹即可。鋼管內(nèi)壁可根據(jù)地區(qū)情況,每2~4年涂刷一次,每次涂刷兩遍。角鋼、桁架和其他鐵件可每年涂刷一次。扣件要涂油,螺栓宜鍍鋅防銹,使用3~5年保護(hù)層剝落后再次鍍鋅。沒有鍍鋅條件的,應(yīng)在每次使用后用煤油洗滌并涂機(jī)油防銹。木制件應(yīng)做好防腐處理,鋼制件應(yīng)涂紅丹及防銹涂料;(4)搬運(yùn)長鋼管、長角鋼時,應(yīng)采取措施防止彎曲。拆架應(yīng)拆成單片裝運(yùn),裝卸時不得拋丟,防止損壞;(5)腳手架使用的扣件、螺栓、螺母、墊板、連接棒、插銷等小配件極易丟失。在安裝腳手架時,多余的小配件應(yīng)及時收回存放,在拆卸腳手架時,散落在地面上的小配件要及時收撿起來;(6)健全制度,加強(qiáng)管理,減少損耗和提高效益是腳手架管理的中心環(huán)節(jié)。比較普遍采用的管理辦法有兩種1)由架子工班(組)管理,采用誰使用、誰維護(hù)、誰管理的原則,并建立積極地獎罰制度、做到確保施工需要,用畢及時歸庫、及時清理和及時維修保養(yǎng),減少丟失和損耗;2)由材料部門集中管理,實行租賃制。施工隊根據(jù)施工的需要向公司材料部門租賃腳手架材料,實行按天計費(fèi)和損壞賠償制度。九、應(yīng)急預(yù)案1、目的提高整個項目組對事故的整體應(yīng)急能力,確保意外發(fā)生的時候能有序的應(yīng)急指揮,為有效、及時的搶救傷員,防止事故的擴(kuò)大,減少經(jīng)濟(jì)損失,保護(hù)生態(tài)環(huán)境和資源,把事故降低到最小程度,制定本預(yù)案。2、應(yīng)急領(lǐng)導(dǎo)小組及其職責(zé)應(yīng)急領(lǐng)導(dǎo)小組由組長、副組長、成員等構(gòu)成。(1)領(lǐng)導(dǎo)各單位應(yīng)急小組的培訓(xùn)和演習(xí)工作,提高應(yīng)變能力。(2)當(dāng)發(fā)生突發(fā)事故時,負(fù)責(zé)救險的人員、器材、車輛、通信和組織指揮協(xié)調(diào)。(3)負(fù)責(zé)準(zhǔn)備所需要的應(yīng)急物資和應(yīng)急設(shè)備。(4)及時到達(dá)現(xiàn)場進(jìn)行指揮,控制事故的擴(kuò)大,并迅速向上級報告。3、應(yīng)急反應(yīng)預(yù)案(1)事故報告程序事故發(fā)生后,作業(yè)人員、班組長、現(xiàn)場負(fù)責(zé)人、項目部安全主管領(lǐng)導(dǎo)應(yīng)逐級上報,并聯(lián)絡(luò)報警,組織搶救。(2)事故報告事故發(fā)生后應(yīng)逐級上報:一般為現(xiàn)場事故知情人員、作業(yè)隊、班組安全員、施工單位專職安全員。發(fā)生重大事故時,應(yīng)立即向上級領(lǐng)導(dǎo)匯報,并在24小時內(nèi)向上級主管部門作出書面報告。(3)現(xiàn)場事故應(yīng)急處理施工過程中可能發(fā)生的事故主要有:機(jī)具傷人、火災(zāi)事故、雷擊觸電事故、高溫中暑、中毒窒息、高空墜落、落物傷人等事故?;馂?zāi)事故應(yīng)急處理:及時報警,組織撲救,集中力量控制火勢。消滅飛火疏散物資減少損失控制火勢蔓延。注意人身安全,積極搶救被困人員,配合消防人員撲滅大火。觸電事故處理:立即切斷電源或者用干燥的木棒、竹竿等絕緣工具把電線挑開。傷員被救后,觀察其呼吸、心跳情況,必要時,可采取人工呼吸、心臟擠壓術(shù),并且注意其他損傷的處理。局部電擊時,應(yīng)對傷員進(jìn)行早期清創(chuàng)處理,創(chuàng)面宜暴露,不宜包扎,發(fā)生內(nèi)部組織壞死時,必須注射破傷風(fēng)抗菌素。高溫中暑的應(yīng)急處理:將中暑人員移至陰涼的地方,解開衣服讓其平臥,頭部不要墊高。用涼水或50%酒精擦其全身,直至皮膚發(fā)紅,血管擴(kuò)張以促進(jìn)散熱,降溫過程中要密切觀察。及時補(bǔ)充水分和無機(jī)鹽,及時處理呼吸、循環(huán)衰竭,醫(yī)療條件不完善時,及時送醫(yī)院治療。其他人身傷害事故處理:當(dāng)發(fā)生如高空墜落、被高空墜物擊中、中毒窒息和機(jī)具傷人等人身傷害時,應(yīng)立即向項目部報告、排除其他隱患,防止救援人員受到傷害,積極對傷員進(jìn)行搶救。4、應(yīng)急物資常備藥品:消毒用品、急救物品(繃帶、無菌敷料)及各種常用小夾板、擔(dān)架、止血袋、切割機(jī)等。5、應(yīng)急通信聯(lián)絡(luò)項目負(fù)責(zé)人:唐天通手機(jī)目技術(shù)負(fù)責(zé)人:楊睿手機(jī)全員:劉芳手機(jī)院救護(hù)中心:120匪警:110火警:119通信聯(lián)系方式應(yīng)在施工現(xiàn)場和營地的顯要位置張貼,以便緊急情況下使用。6、注意事項1、人工胸外心臟按壓、人工呼吸不能輕意的放棄,必須堅持到底。2、如現(xiàn)場發(fā)生人身意外傷害事故,如當(dāng)事人沒有自覺癥狀,不要輕易放走當(dāng)事人,醫(yī)務(wù)人員要對其進(jìn)行全面檢查并觀察24小時,確實沒有損傷時才能視為正常。3、當(dāng)發(fā)現(xiàn)傷員心跳、呼吸停止時要應(yīng)地?fù)尵龋M(jìn)行心臟復(fù)蘇,直至急救醫(yī)務(wù)人員到場進(jìn)一步搶救。4、現(xiàn)場發(fā)生人身意外傷害事故,不要慌亂,派專人守在傷員前進(jìn)行臨時救護(hù),另派人與急救中心或醫(yī)院聯(lián)系說明傷員所處地點,行車路線及達(dá)到所在地點的明顯標(biāo)志。5、對于骨折傷員,特別是懷疑頸、胸腰椎骨折傷員要做好固定,用硬板搬運(yùn),不得隨意拉扯、扭曲身體搬運(yùn)。十、懸挑式扣件鋼管腳手架計算書鋼管腳手架的計算參照《建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范》JGJ130-2011雙排腳手架,搭設(shè)高度17.7米,立桿采用單立管。立桿的縱距1.50米,立桿的橫距0.70米,內(nèi)排架距離結(jié)構(gòu)0.40米,立桿的步距1.45米。采用的鋼管類型為48×3.5,連墻件采用2步2跨,豎向間距2.90米,水平間距3.00米。施工活荷載為3.0kN/m2,同時考慮2層施工。腳手板采用竹笆片,荷載為0.15kN/m2,按照鋪設(shè)4層計算。欄桿采用竹笆片,荷載為0.15kN/m,安全網(wǎng)荷載取0.0050kN/m2。腳手板下小橫桿在大橫桿上面,且主結(jié)點間增加一根小橫桿?;撅L(fēng)壓0.45kN/m2,高度變化系數(shù)1.2500,體型系數(shù)0.6000。懸挑水平鋼梁采用16號工字鋼,其中建筑物外懸挑段長度1.20米,建筑物內(nèi)錨固段長度1.80米。懸挑水平鋼梁采用拉桿與建筑物拉結(jié),最外面支點距離建筑物1.00m。拉桿采用鋼絲繩。一、小橫桿的計算小橫桿按照簡支梁進(jìn)行強(qiáng)度和撓度計算,小橫桿在大橫桿的上面。按照小橫桿上面的腳手板和活荷載作為均布荷載計算小橫桿的最大彎矩和變形。1.均布荷載值計算小橫桿的自重標(biāo)準(zhǔn)值P1=0.038kN/m腳手板的荷載標(biāo)準(zhǔn)值P2=0.150×1.500/2=0.113kN/m活荷載標(biāo)準(zhǔn)值Q=3.000×1.500/2=2.250kN/m荷載的計算值q=1.2×0.038+1.2×0.113+1.4×2.250=3.331kN/m小橫桿計算簡圖2.抗彎強(qiáng)度計算最大彎矩考慮為簡支梁均布荷載作用下的彎矩計算公式如下:M=3.331×0.7002/8=0.204kN.m=0.204×106/5080.0=40.163N/mm2小橫桿的計算強(qiáng)度小于205.0N/mm2,滿足要求!3.撓度計算最大撓度考慮為簡支梁均布荷載作用下的撓度計算公式如下:荷載標(biāo)準(zhǔn)值q=0.038+0.113+2.250=2.401kN/m簡支梁均布荷載作用下的最大撓度V=5.0×2.401×700.04/(384×2.06×105×121900.0)=0.299mm小橫桿的最大撓度小于700.0/150與10mm,滿足要求!二、大橫桿的計算大橫桿按照三跨連續(xù)梁進(jìn)行強(qiáng)度和撓度計算,小橫桿在大橫桿的上面。用小橫桿支座的最大反力計算值,在最不利荷載布置下計算大橫桿的最大彎矩和變形。1.荷載值計算小橫桿的自重標(biāo)準(zhǔn)值P1=0.038×0.700=0.027kN腳手板的荷載標(biāo)準(zhǔn)值P2=0.150×0.700×1.500/2=0.079kN活荷載標(biāo)準(zhǔn)值Q=3.000×0.700×1.500/2=1.575kN荷載的計算值P=(1.2×0.027+1.2×0.079+1.4×1.575)/2=1.166kN大橫桿計算簡圖2.抗彎強(qiáng)度計算最大彎矩考慮為大橫桿自重均布荷載與荷載的計算值最不利分配的彎矩和均布荷載最大彎矩計算公式如下:集中荷載最大彎矩計算公式如下:M=0.08×(1.2×0.038)×1.5002+0.175×1.166×1.500=0.314kN.m=0.314×106/5080.0=61.877N/mm2大橫桿的計算強(qiáng)度小于205.0N/mm2,滿足要求!3.撓度計算最大撓度考慮為大橫桿自重均布荷載與荷載的計算值最不利分配的撓度和均布荷載最大撓度計算公式如下:集中荷載最大撓度計算公式如下:大橫桿自重均布荷載引起的最大撓度V1=0.677×0.038×1500.004/(100×2.060×105×121900.000)=0.05mm集中荷載標(biāo)準(zhǔn)值P=0.027+0.079+1.575=1.681kN集中荷載標(biāo)準(zhǔn)值最不利分配引起的最大撓度V1=1.146×1680.630×1500.003/(100×2.060×105×121900.000)=2.59mm最大撓度和V=V1+V2=2.641mm大橫桿的最大撓度小于1500.0/150與10mm,滿足要求!三、扣件抗滑力的計算縱向或橫向水平桿與立桿連接時,扣件的抗滑承載力按照下式計算(規(guī)范5.2.5):R≤Rc其中Rc——扣件抗滑承載力設(shè)計值,取8.0kN;R——縱向或橫向水平桿傳給立桿的豎向作用力設(shè)計值;1.荷載值計算橫桿的自重標(biāo)準(zhǔn)值P1=0.038×1.500=0.058kN腳手板的荷載標(biāo)準(zhǔn)值P2=0.150×0.700×1.500/2=0.079kN活荷載標(biāo)準(zhǔn)值Q=3.000×0.700×1.500/2=1.575kN荷載的計算值R=1.2×0.058+1.2×0.079+1.4×1.575=2.369kN單扣件抗滑承載力的設(shè)計計算滿足要求!當(dāng)直角扣件的擰緊力矩達(dá)40--65N.m時,試驗表明:單扣件在12kN的荷載下會滑動,其抗滑承載力可取8.0kN;雙扣件在20kN的荷載下會滑動,其抗滑承載力可取12.0kN;四、腳手架荷載標(biāo)準(zhǔn)值作用于腳手架的荷載包括靜荷載、活荷載和風(fēng)荷載。靜荷載標(biāo)準(zhǔn)值包括以下內(nèi)容:(1)每米立桿承受的結(jié)構(gòu)自重標(biāo)準(zhǔn)值(kN/m);本例為0.1394NG1=0.139×20.000=2.788kN(2)腳手板的自重標(biāo)準(zhǔn)值(kN/m2);本例采用竹笆片腳手板,標(biāo)準(zhǔn)值為0.15NG2=0.150×4×1.500×(0.700+0.400)/2=0.495kN(3)欄桿與擋腳手板自重標(biāo)準(zhǔn)值(kN/m);本例采用欄桿、竹笆片腳手板擋板,標(biāo)準(zhǔn)值為0.15NG3=0.150×1.500×4/2=0.450kN(4)吊掛的安全設(shè)施荷載,包括安全網(wǎng)(kN/m2);0.005NG4=0.005×1.500×20.000=0.150kN經(jīng)計算得到,靜荷載標(biāo)準(zhǔn)值NG=NG1+NG2+NG3+NG4=3.883kN?;詈奢d為施工荷載標(biāo)準(zhǔn)值產(chǎn)生的軸向力總和,內(nèi)、外立桿按一縱距內(nèi)施工荷載總和的1/2取值。經(jīng)計算得到,活荷載標(biāo)準(zhǔn)值NQ=3.000×2×1.500×0.700/2=3.150kN風(fēng)荷載標(biāo)準(zhǔn)值應(yīng)按照以下公式計算其中W0——基本風(fēng)壓(kN/m2),按照《建筑結(jié)構(gòu)荷載規(guī)范》(GB50009-2001)附錄表D.4的規(guī)定采用:W0=0.450Uz——風(fēng)荷載高度變化系數(shù),按照《建筑結(jié)構(gòu)荷載規(guī)范》(GB50009-2001)附錄表7.2.1的規(guī)定采用:Uz=1.250Us——風(fēng)荷載體型系數(shù):Us=0.600經(jīng)計算得到,風(fēng)荷載標(biāo)準(zhǔn)值Wk=0.7×0.450×1.250×0.600=0.236kN/m2。考慮風(fēng)荷載時,立桿的軸向壓力設(shè)計值計算公式N=1.2NG+0.85×1.4NQ經(jīng)過計算得到,底部立桿的最大軸向壓力N=1.2×3.883+0.85×1.4×3.150=8.408kN不考慮風(fēng)荷載時,立桿的軸向壓力設(shè)計值計算公式N=1.2NG+1.4NQ經(jīng)過計算得到,底部立桿的最大軸向壓力N=1.2×3.883+1.4×3.150=9.070kN風(fēng)荷載設(shè)計值產(chǎn)生的立桿段彎矩MW計算公式MW=0.85×1.4Wklah2/10其中Wk——風(fēng)荷載標(biāo)準(zhǔn)值(kN/m2);la——立桿的縱距(m);h——立桿的步距(m)。經(jīng)過計算得到風(fēng)荷載產(chǎn)生的彎矩Mw=0.85×1.4×0.236×1.500×1.450×1.450/10=0.089kN.m五、立桿的穩(wěn)定性計算1.不考慮風(fēng)荷載時,立桿的穩(wěn)定性計算其中N——立桿的軸心壓力設(shè)計值,N=9.070kN;i——計算立桿的截面回轉(zhuǎn)半徑,i=1.58cm;k——計算長度附加系數(shù),取1.155;u——計算長度系數(shù),由腳手架的高度確定,u=1.500;l0——計算長度(m),由公式l0=kuh確定,l0=1.155×1.500×1.450=2.512m;A——立桿凈截面面積,A=4.890cm2;W——立桿凈截面模量(抵抗矩),W=5.080cm3;——由長細(xì)比,為2512/16=159;——軸心受壓立桿的穩(wěn)定系數(shù),由長細(xì)比l0/i的結(jié)果查表得到0.280;——鋼管立桿受壓強(qiáng)度計算值(N/mm2);經(jīng)計算得到=9070/(0.28×489)=66.135N/mm2;[f]——鋼管立桿抗壓強(qiáng)度設(shè)計值,[f]=205.00N/mm2;不考慮風(fēng)荷載時,立桿的穩(wěn)定性計算<[f],滿足要求!2.考慮風(fēng)荷載時,立桿的穩(wěn)定性計算其中N——立桿的軸心壓力設(shè)計值,N=8.408kN;i——計算立桿的截面回轉(zhuǎn)半徑,i=1.58cm;k——計算長度附加系數(shù),取1.155;u——計算長度系數(shù),由腳手架的高度確定,u=1.500;l0——計算長度(m),由公式l0=kuh確定,l0=1.155×1.500×1.450=2.512m;A——立桿凈截面面積,A=4.890cm2;W——立桿凈截面模量(抵抗矩),W=5.080cm3;——由長細(xì)比,為2512/16=159;——軸心受壓立桿的穩(wěn)定系數(shù),由長細(xì)比l0/i的結(jié)果查表得到0.280;MW——計算立桿段由風(fēng)荷載設(shè)計值產(chǎn)生的彎矩,MW=0.089kN.m;——鋼管立桿受壓強(qiáng)度計算值(N/mm2);經(jīng)計算得到=8408/(0.28×489)+89000/5080=78.765N/mm2;[f]——鋼管立桿抗壓強(qiáng)度設(shè)計值,[f]=205.00N/mm2;考慮風(fēng)荷載時,立桿的穩(wěn)定性計算<[f],滿足要求!六、連墻件的計算連墻件的軸向力計算值應(yīng)按照下式計算:Nl=Nlw+No其中Nlw——風(fēng)荷載產(chǎn)生的連墻件軸向力設(shè)計值(kN),應(yīng)按照下式計算:Nlw=1.4×wk×Awwk——風(fēng)荷載標(biāo)準(zhǔn)值,wk=0.236kN/m2;Aw——每個連墻件的覆蓋面積內(nèi)腳手架外側(cè)的迎風(fēng)面積,Aw=2.90×3.00=8.700m2;No——連墻件約束腳手架平面外變形所產(chǎn)生的軸向力(kN);No=5.000經(jīng)計算得到Nlw=2.878kN,連墻件軸向力計算值Nl=7.878kN連墻件軸向力設(shè)計值Nf=A[f]其中——軸心受壓立桿的穩(wěn)定系數(shù),由長細(xì)比l/i=40.00/1.58的結(jié)果查表得到=0.93;A=4.89cm2;[f]=205.00N/mm2。經(jīng)過計算得到Nf=93.484kNNf>Nl,連墻件的設(shè)計計算滿足要求!連墻件拉結(jié)樓板預(yù)埋鋼管示意圖七、懸挑梁的受力計算懸挑腳手架的水平鋼梁按照帶懸臂的連續(xù)梁計算。懸臂部分腳手架荷載N的作用,里端B為與樓板的錨固點,A為墻支點。本工程中,腳手架排距為700mm,內(nèi)側(cè)腳手架距離墻體400mm,支拉斜桿的支點距離墻體=1000mm,水平支撐梁的截面慣性矩I=1130.00cm4,截面抵抗矩W=141.00cm3,截面積A=26.10cm2。受腳手架集中荷載P=9.07kN水平鋼梁自重荷載q=1.2×26.10×0.0001×7.85×10=0.25kN/m懸挑腳手架示意圖懸挑腳手架計算簡圖經(jīng)過連續(xù)梁的計算得到懸挑腳手架支撐梁剪力圖(kN)懸挑腳手架支撐梁彎矩圖(kN.m)懸挑腳手架支撐梁變形圖(mm)各支座對支撐梁的支撐反力由左至右分別為R1=13.247kN,R2=5.705kN,R3=-0.075kN最大彎矩Mmax=1.521kN.m抗彎計算強(qiáng)度f=M/1.05W+N/A=1.521×106/(1.05×141000.0)+4.568×1000/2610.0=12.024N/mm2水平支撐梁的抗彎計算強(qiáng)度小于215.0N/mm2,滿足要求!八、懸挑梁的整體穩(wěn)定性計算水平鋼梁采用16號工字鋼,計算公式如下其中b——均勻彎曲的受彎構(gòu)件整體穩(wěn)定系數(shù),查表《鋼結(jié)構(gòu)設(shè)計規(guī)范》(GB50017-2003)附錄B得到:b=2.00由于b大于0.6,按照《鋼結(jié)構(gòu)設(shè)計規(guī)范》(GB50017-2003)附錄B其值b'=1.07-0.282/b=0.929經(jīng)過計算得到強(qiáng)度=1.52×106/(0.929×141000.00)=11.61N/mm2;水平鋼梁的穩(wěn)定性計算<[f],滿足要求!九、拉桿的受力計算水平鋼梁的軸力RAH和拉鋼繩的軸力RUi按照下面計算其中RUicosi為鋼繩的拉力對水平桿產(chǎn)生的軸壓力。各支點的支撐力RCi=RUisini按照以上公式計算得到由左至右各鋼繩拉力分別為RU1=14.013kN十、拉桿的強(qiáng)度計算拉繩或拉桿的軸力RU我們均取最大值進(jìn)行計算,為RU=14.013kN拉繩的強(qiáng)度計算:如果上面采用鋼絲繩,鋼絲繩的容許拉力按照下式計算:其中[Fg]——鋼絲繩的容許拉力(kN);Fg——鋼絲繩的鋼絲破斷拉力總和(kN);——鋼絲繩之間的荷載不均勻系數(shù),對6×19、6×37、6×61鋼絲繩分別取0.85、0.82和0.8;K——鋼絲繩使用安全系數(shù)。選擇拉鋼絲繩的破斷拉力要大于8.000×14.013/0.850=131.885kN。選擇6×19+1鋼絲繩,鋼絲繩公稱抗拉強(qiáng)度1400MPa,直徑17.0mm。鋼絲拉繩的吊環(huán)強(qiáng)度計算:鋼絲拉繩的軸力RU我們均取最大值進(jìn)行計算作為吊環(huán)的拉力N,為N=RU=14.013kN鋼絲拉繩的吊環(huán)強(qiáng)度計算公式為其中[f]為吊環(huán)抗拉強(qiáng)度,取[f]=50N/mm2,每個吊環(huán)按照兩個截面計算;所需要的鋼絲拉繩的吊環(huán)最小直徑D=[14013×4/(3.1416×50×2)]1/2=14mm十一、錨固段與樓板連接的計算1.水平鋼梁與樓板壓點如果采用鋼筋拉環(huán),拉環(huán)強(qiáng)度計算如下:水平鋼梁與樓板壓點的拉環(huán)受力R=5.705kN水平鋼梁與樓板壓點的拉環(huán)強(qiáng)度計算公式為其中[f]為拉環(huán)鋼筋抗拉強(qiáng)度,每個拉環(huán)按照兩個截面計算,按照《混凝土結(jié)構(gòu)設(shè)計規(guī)范》10.9.8[f]=50N/mm2;所需要的水平鋼梁與樓板壓點的拉環(huán)最小直徑D=[5705×4/(3.1416×50×2)]1/2=9mm水平鋼梁與樓板壓點的拉環(huán)一定要壓在樓板下層鋼筋下面,并要保證兩側(cè)30cm以上搭接長度。2.水平鋼梁與樓板壓點如果采用螺栓,螺栓粘結(jié)力錨固強(qiáng)度計算如下:錨固深度計算公式其中N——錨固力,即作用于樓板螺栓的軸向拉力,N=5.70kN;d——樓板螺栓的直徑,d=16mm;[fb]——樓板螺栓與混凝土的容許粘接強(qiáng)度,計算中取1.5N/mm2;h——樓板螺栓在混凝土樓板內(nèi)的錨固深度,經(jīng)過計算得到h要大于5704.86/(3.1416×16×1.5)=75.7mm。3.水平鋼梁與樓板壓點如果采用螺栓,混凝土局部承壓計算如下:混凝土局部承壓的螺栓拉力要滿足公式其中N——錨固力,即作用于樓板螺栓的軸向拉力,N=5.70kN;d——樓板螺栓的直徑,d=16mm;b——樓板內(nèi)的螺栓錨板邊長,b=5d=80mm;fcc——混凝土的局部擠壓強(qiáng)度設(shè)計值,計算中取0.95fc=13.59N/mm2;經(jīng)過計算得到公式右邊等于84.2kN樓板混凝土局部承壓計算滿足要求!

附錄資料:不需要的可以自行刪除施工方案及服務(wù)體系項目經(jīng)理項目經(jīng)理是項目實施中最主要的角色。集成商與客戶雙方都需要有人擔(dān)當(dāng)此角色。集成方項目經(jīng)理責(zé)任:負(fù)責(zé)與相關(guān)人員的所有聯(lián)絡(luò)、協(xié)調(diào)工作、向工程總負(fù)責(zé)匯報任何有關(guān)本項目工作的執(zhí)行情況,在系統(tǒng)集成完成測試驗收、并交付給客戶方之前,集成商項目經(jīng)理代表集成商,所有項目實施過程中用戶的情況都統(tǒng)一反映到項目經(jīng)理,簡化用戶反饋過程,以確保項目平穩(wěn)、順利地進(jìn)行。我們每個區(qū)域配備1名項目經(jīng)理,主要包括主要職責(zé):1)

與用戶和協(xié)調(diào)原廠商進(jìn)行工程實施。2)

計劃工程進(jìn)度,劃分工程的子任務(wù)。4)

負(fù)責(zé)工程參與人員的配備并安排的實施過程,負(fù)責(zé)工程的成本。5)

對用戶所提出要求的響應(yīng)。7)

制作和管理工程實施文檔。8)

協(xié)調(diào)解決工程實施過程中出現(xiàn)的不可預(yù)測的問題。9)

向我公司項目總負(fù)責(zé)匯報工作進(jìn)度及相關(guān)需要協(xié)調(diào)的事項。10)

負(fù)責(zé)監(jiān)督和考核工程參與人員的工作。11)

保證項目按合同期限和技術(shù)要求完成,承擔(dān)完成工程目標(biāo)的責(zé)任。12)

承擔(dān)用戶滿意度責(zé)任??蛻舴巾椖拷?jīng)理責(zé)任:擔(dān)當(dāng)用戶與集成商交流的渠道。根據(jù)項目實施小組的要求,在雙方約定的時間之內(nèi),協(xié)助收集、提供有關(guān)用戶方的信息、數(shù)據(jù),作出相應(yīng)的批示和決定。對項目交付事項的接受工作進(jìn)行管理。項目管理小組該小組3人組成,負(fù)責(zé)整個項目的管理,從成本管理、變更管理到溝通管理,涉及整個項目的跟蹤運(yùn)作情況。此外還有1人專門負(fù)責(zé)實施過程中的文檔管理。質(zhì)量監(jiān)督小組該小組2人組成,負(fù)責(zé)整個施工過程中的施工質(zhì)量,規(guī)范執(zhí)行情況,向項目總協(xié)調(diào)及時匯報施工情況,并接受用戶的監(jiān)督。商務(wù)運(yùn)作小組成立商務(wù)運(yùn)作小組,由3人組成。該小組負(fù)責(zé)用戶單位的貨物訂購、接收、轉(zhuǎn)運(yùn)、發(fā)送等事宜。向項目總協(xié)調(diào)匯報負(fù)責(zé),并與用戶方保持緊密的聯(lián)系,按照技術(shù)要求與合同的要求,及時向用戶方通告有關(guān)貨物的運(yùn)轉(zhuǎn)情況。保證在要求的時間內(nèi)完成所有集成工作,貨物的組織將起到關(guān)鍵的作用。其任務(wù)有:1)按照標(biāo)書、合同及設(shè)計方案訂購工程所需的貨物。2)監(jiān)督貨物的全部轉(zhuǎn)運(yùn)過程,包括:裝運(yùn)、報關(guān)、商檢、向各轉(zhuǎn)運(yùn)。3)及時向用戶方通報貨物轉(zhuǎn)運(yùn)的有關(guān)事宜。培訓(xùn)小組成立培訓(xùn)小組,共計3人。培訓(xùn)小組主要負(fù)責(zé)集中基礎(chǔ)技術(shù)培訓(xùn)的組織授課工作。其任務(wù)有:1)按照標(biāo)書、合同及方案的要求,制定培訓(xùn)計劃。2)編寫培訓(xùn)教材3)組織、安排和實施培訓(xùn)。4)提交培訓(xùn)報告。實施小組負(fù)責(zé)人實施小組由6人組成,每設(shè)立負(fù)責(zé)人1名,該負(fù)責(zé)人具有精通本項目所需要的某專項技術(shù),同時具備很好的用戶需求理解能力。在項目實施的各個階段通過自身技術(shù)專長安排各任務(wù)小組及時實現(xiàn)用戶需求,并向項目經(jīng)理及時匯報項目進(jìn)展情況。主要職責(zé)如下:1)

依照本規(guī)定,完成項目經(jīng)理安排的任務(wù)。2)

向項目經(jīng)理匯報工作進(jìn)展情況,反饋用戶的要求與意見。3)

負(fù)責(zé)任務(wù)準(zhǔn)備期和實施期與用戶的協(xié)調(diào)工作。4)

安排本任務(wù)小組成員的分配實施工作。5)

制作更新與任務(wù)相關(guān)的工程文檔。6)

解決工程實施過程中出現(xiàn)的不可預(yù)測、妨礙進(jìn)度的因素。7)

承擔(dān)完成所接受任務(wù)的責(zé)任。8)

承擔(dān)用戶滿意度的責(zé)任。任務(wù)小組設(shè)置5名實施人員,所采購的設(shè)備中包括主機(jī)、網(wǎng)絡(luò)、安全、系統(tǒng)及網(wǎng)絡(luò)管理等相關(guān)軟硬件設(shè)備,對各技術(shù)領(lǐng)域都需要對該領(lǐng)域具有特長的工程師來完成,因此,相應(yīng)的安排了主機(jī)實施小組、網(wǎng)絡(luò)實施小組、安全實施小組、系統(tǒng)軟件實施小組來分別完成該項目中相關(guān)的技術(shù)實施,各任務(wù)小組在實施小組負(fù)責(zé)人的統(tǒng)一調(diào)度下,協(xié)力完成整個系統(tǒng)的實施,各任務(wù)小組根據(jù)所實施的設(shè)備形成相關(guān)設(shè)備的實施配置文檔提交用戶存檔。任務(wù)小組參與人員的職責(zé)如下:1)

依照實施小組負(fù)責(zé)人的要求協(xié)同完成工程安排的任務(wù)。2)

及時反饋用戶的要求與意見。3)

在任務(wù)實施期與用戶的協(xié)調(diào)工作。4)

制作更新與任務(wù)相關(guān)的工程文檔。5)

解決工程實施過程中出現(xiàn)的不可預(yù)測、妨礙進(jìn)度的因素。6)

承擔(dān)完成所接受任務(wù)的責(zé)任。7)

承擔(dān)用戶滿意度的責(zé)任。機(jī)動小組4人,根據(jù)項目實際運(yùn)作過程中的情況,用于靈活調(diào)度補(bǔ)充到實施小組中的成員,保證工程的實施進(jìn)度和人員配備計劃。售后服務(wù)小組在項目所在地設(shè)置4名專業(yè)工程師,為用戶提供及時地本地化服務(wù);此外在遠(yuǎn)恒至盛公司總部將有專家中心10人為本項目提供專家級的服務(wù)支持。關(guān)于服務(wù)的組織結(jié)構(gòu)和人員安排參見“系統(tǒng)維護(hù)與技術(shù)支持”小節(jié)。工程實施流程系統(tǒng)集成工作的實施流程依次包括立項、計劃、準(zhǔn)備、實施、驗收五個順序階段。各階段任務(wù)安排如下:工程實施的管理與考核整個工程實施過程中要對整個項目的實施進(jìn)行管理與考核,對于每一個實施階段對應(yīng)不同的考核措施和標(biāo)準(zhǔn),以加強(qiáng)工程實施的成效性。對項目經(jīng)理的考核為保證工程實施的質(zhì)量和保證工程的實施進(jìn)度,對整個工程的系統(tǒng)集成工作要進(jìn)行管理與考核,整個管理和考核以項目經(jīng)理為主要考核對象,以其所劃分出的各種不同子任務(wù)的目標(biāo)責(zé)任制進(jìn)行對任務(wù)參與人員的管理和考核。任務(wù)完成考核的范圍系統(tǒng)集成工作性質(zhì)主要分為六個方面,根據(jù)這個范圍每個工程參與人員都有可能承擔(dān)其中一項或多項范圍內(nèi)的工作子任務(wù):1)

搭建系統(tǒng)硬件平臺及配套工程設(shè)計實施2)

主機(jī)系統(tǒng)安裝調(diào)試3)

網(wǎng)絡(luò)系統(tǒng)的安裝調(diào)試4)

配置網(wǎng)絡(luò)設(shè)備與網(wǎng)絡(luò)調(diào)試5)安全系統(tǒng)的安裝調(diào)試6)

系統(tǒng)功能調(diào)測7)

系統(tǒng)性能調(diào)測工程實施規(guī)范的主要管理工程規(guī)范的管理包括工程文檔管理、工程準(zhǔn)備管理、工程實施管理和工程驗收管理四大部分。工程實施文檔管理工程實施文檔是規(guī)范整個工程所需的各類文檔,是貫串系統(tǒng)集成管理規(guī)范最重要的紐帶。工程的其他管理都必須緊緊與文檔管理相結(jié)合。文檔的制作是考核工程參與人員的依據(jù)。有關(guān)文檔的提交及管理的詳細(xì)內(nèi)容參見“4.4.10文檔提交及管理”子任務(wù)完成管理與考核

對于每一項子任務(wù)的完成,根據(jù)其任務(wù)按“任務(wù)完成考核的范圍”劃分性質(zhì)進(jìn)行的管理。工程準(zhǔn)備管理針對工程參與人員從接受任務(wù)開始至到用戶現(xiàn)場前所的準(zhǔn)備工作。工程實施管理針對工程參與人員的用戶現(xiàn)場的工作。工程實施驗收管理驗收管理是公司與用戶共同檢驗工程是否達(dá)到預(yù)定目標(biāo)并進(jìn)行最終確認(rèn)的重要一環(huán),是直接關(guān)系到公司利益的重要工作,每個成員必須高度重視,支持項目驗收工作。對任務(wù)小組實施人員的主要考核內(nèi)容包括:1)

任務(wù)完成情況,是否按期完成技術(shù)要求2)

完成任務(wù)的工作比重3)

任務(wù)實施成本的考核4)

對新產(chǎn)品新技術(shù)的掌握程度5)

任務(wù)相關(guān)文檔的制作6)

工作態(tài)度和工作規(guī)范7)

與同事的協(xié)同工作能力8)

與用戶、廠商關(guān)系的協(xié)調(diào)9)

用戶滿意度實施準(zhǔn)備工作為了保證工程在后續(xù)實施過程的規(guī)范,在合同簽訂后進(jìn)入實施準(zhǔn)備工作階段,該階段,我們從商務(wù)到技術(shù),在與客戶充分溝通的基礎(chǔ)上,制定項目的詳細(xì)實施計劃和有關(guān)的技術(shù)準(zhǔn)備工作,為現(xiàn)場實施作充分的準(zhǔn)備。整個的實施準(zhǔn)備期主要準(zhǔn)備如下工作:公司相關(guān)部門和系統(tǒng)集成事業(yè)部共同任命項目總負(fù)責(zé)和項目經(jīng)理,同時就工程所需達(dá)到的各項技術(shù)指標(biāo)等進(jìn)行明確的規(guī)定。項目經(jīng)理在接受任命后,在10日之內(nèi)向部門負(fù)責(zé)人提交項目實施計劃,項目實施計劃涉及工作量估算、項目進(jìn)度、人員配置計劃等內(nèi)容,經(jīng)部門負(fù)責(zé)人批準(zhǔn)后方可正式實施。項目經(jīng)理在項目計劃批準(zhǔn)后,在項目啟動之初,形成工程實施任務(wù),任命實施小組技術(shù)負(fù)責(zé)人,并遵循有關(guān)約定,作好IP地址的總體分配方案,包括可用地址范圍、中心局域網(wǎng)地址范圍、廣域網(wǎng)地址范圍、遠(yuǎn)程網(wǎng)點地址范圍、備用策略及相應(yīng)地址范圍。同時,項目經(jīng)理向工程參與人員安排相應(yīng)的任務(wù),包括設(shè)備到貨清單列表、設(shè)備參數(shù)表、系統(tǒng)測試驗收計劃草案、各類課程集中技術(shù)培訓(xùn)文檔等準(zhǔn)備文檔。因為本項目也涉及到廠方工程師的參與,因此項目經(jīng)理和實施小組負(fù)責(zé)人還要全面考慮和落實廠方工程師在本項目中的參與程度,并聯(lián)系廠家負(fù)責(zé)人確定實施工程師的職責(zé)安排。工程參與人員按照實施小組負(fù)責(zé)人或項目經(jīng)理的任務(wù)安排,必須充分利用公司的資源,全面考慮先期的準(zhǔn)備工作,根據(jù)實際需要,制作工程準(zhǔn)備期相應(yīng)的文檔資料,預(yù)先設(shè)計任務(wù)測試內(nèi)容,需要用戶作的先期準(zhǔn)備工作則應(yīng)與用戶以書面形式聯(lián)系進(jìn)行確認(rèn),如機(jī)房環(huán)境要求文檔、布線和通訊線路到位情況等等,并向項目經(jīng)理或?qū)嵤┬〗M負(fù)責(zé)人提交任務(wù)準(zhǔn)備完成情況。工作分配矩陣涉及多個廠家的產(chǎn)品和服務(wù),同時也涉及了不同的技術(shù)層面從服務(wù)器、存儲到網(wǎng)絡(luò)、安全等各方面的技術(shù)內(nèi)容,為了保證整個工作的順利進(jìn)行,需要對參與工程的每個人或小組明確職責(zé),作為集成商,我們除了利用自己的實力來完成工作中的相應(yīng)任務(wù)外,還將協(xié)調(diào)和安排各廠家參與到該項目中實施技術(shù)人員的職責(zé)安排,督促用戶對現(xiàn)場環(huán)境的準(zhǔn)備。這就牽涉到了工作中責(zé)任的分配矩陣,也就是將所分解的工作任務(wù)落實到項目有關(guān)部門或個人,并明確的表示出他在組織工作中的關(guān)系、責(zé)任和地位的一種方法和工具??傊?,通過工作矩陣的分配,最終在在項目協(xié)調(diào)委員會的統(tǒng)一領(lǐng)導(dǎo)下,在項目單位的大力配合下,密切聯(lián)合和調(diào)配各產(chǎn)品供應(yīng)商,密切合作,分工明確,共同建好系統(tǒng)平臺構(gòu)建工作。設(shè)備及系統(tǒng)配置要點檢查與準(zhǔn)備現(xiàn)場實施環(huán)境的實施小組負(fù)責(zé)人按照項目實施日程到用戶現(xiàn)場后,首先向用戶現(xiàn)場負(fù)責(zé)人通報主要工作目標(biāo),檢查先期的準(zhǔn)備工作,提出需用戶方配合的工作及必備的人員與物資條件。現(xiàn)場實施環(huán)境的檢查與準(zhǔn)備主要包括如下內(nèi)容:與用戶現(xiàn)場負(fù)責(zé)人確認(rèn)設(shè)備位置。確認(rèn)提供的工作電壓和電源功率。電氣參數(shù):電壓220V,頻率50HZ靜電接地:為保證及時泄掉各種設(shè)備產(chǎn)生的靜電,防止因靜電造成的損害,接點電阻要小于1歐姆。UPS輸出:測試UPS輸出是否滿足設(shè)備需求。機(jī)房溫度:保持在5-35攝氏度機(jī)房濕度:保持在30%-85%干擾:沒有強(qiáng)電/磁干擾。其他物質(zhì):無其他腐蝕性化學(xué)物質(zhì)。檢查設(shè)備的工作環(huán)境。檢查工作臺是否到位、局域網(wǎng)布線是否可用。對于不符合設(shè)計的條件,要區(qū)分是否影響安裝設(shè)備的安全。若影響安裝的設(shè)備安全,向用戶場負(fù)責(zé)人指出,提出相應(yīng)的補(bǔ)救措施,并在結(jié)束任務(wù)前以書面形式遞交用戶現(xiàn)場負(fù)責(zé)人。安裝設(shè)備時的防靜電措施。確保設(shè)備安裝的整潔和牢靠。將上述設(shè)備到貨單填寫一式兩份,與用戶雙方簽字后各留一份。服務(wù)體系服務(wù)承諾函多年以政府、教育行業(yè)及企事業(yè)單位為主導(dǎo)的經(jīng)營方針,使成都旺峰科技發(fā)展有限公司(以下簡稱旺峰科技)深刻體會到做好“服務(wù)”是企業(yè)生存的根本。經(jīng)過多年的發(fā)展和摸索,旺峰科技形成了一整套完善的客戶服務(wù)體系。它能夠為用戶提供一體化的軟硬件的集成服務(wù),確保我們每一個項目的正常管理和服務(wù)運(yùn)行。在本次項目中,旺峰科技將提供3年以上本科學(xué)歷,具有豐富經(jīng)驗的、具有原廠商專業(yè)認(rèn)證的中高級以上資質(zhì)(CCNP和CCIE認(rèn)證工程師)進(jìn)行安裝、調(diào)試、培訓(xùn)等。同時能夠提供5*8小時的現(xiàn)場技術(shù)支持和7*24小時的電話支持,半小時售后響應(yīng),6小時內(nèi)(到達(dá)產(chǎn)品交付地點進(jìn)行故障定位及維修。同時對緊急故障、重大節(jié)日、重要活動進(jìn)行現(xiàn)場技術(shù)保障與支持服務(wù),并對關(guān)鍵部件提供備件服務(wù)。質(zhì)保期內(nèi)的服務(wù)承諾:保證提供原廠商規(guī)定的產(chǎn)品質(zhì)量保證期限(質(zhì)保期為1年)。承諾終身技術(shù)支持及上門服務(wù)。保證不管用戶故障級別屬于哪類,在電話支持解決不了問題的情況下,旺峰科技技術(shù)人員半小時響應(yīng),6小時內(nèi)到達(dá)用戶現(xiàn)場,保證設(shè)備正常運(yùn)行。成立本項目技術(shù)支持小組:保證向用戶提供具有原廠認(rèn)證的中高級以上資質(zhì)(具有原廠認(rèn)證的CCNP、CCIE)的技術(shù)人員現(xiàn)場支持。保證向用戶提供每月1次的現(xiàn)場巡檢服務(wù),并提交巡檢報告。保證向用戶提供5*8小時現(xiàn)場技術(shù)支持服務(wù)和7*24小時的電話支持,并應(yīng)設(shè)備和業(yè)務(wù)情況增派除駐場技術(shù)人員之外的其他技術(shù)人員到現(xiàn)場技術(shù)支持,若此項目設(shè)備有重大故障,我方可協(xié)調(diào)廠家技術(shù)人員和本公司的具有原廠認(rèn)證的中高級以上資質(zhì)的技術(shù)人員時解決相關(guān)問題,同時提供備機(jī)服務(wù)。保證向用戶提供技術(shù)培訓(xùn)。在保修期內(nèi),如遇軟件產(chǎn)品升級、改版,免費(fèi)提供更新、升級服務(wù)。在質(zhì)保期內(nèi),我公司所有服務(wù)不收取任何費(fèi)用。系統(tǒng)運(yùn)行過程中如果出現(xiàn)技術(shù)故障(如硬件故障、軟件故障、配置丟失等),在此期間按緊急預(yù)案處置,確保系統(tǒng)最大限度地不中斷運(yùn)行。此時我方保證對用戶提供4小時內(nèi)解決此類問題的緊急預(yù)案,以恢復(fù)故障使得系統(tǒng)得以正常運(yùn)行。備注:檢驗和驗收標(biāo)準(zhǔn)------在交貨前,我方對貨物的質(zhì)量、規(guī)格、性能、數(shù)量和重量等進(jìn)行詳細(xì)而全面的檢驗,并出具證明貨物符合合同規(guī)定的文件(即出廠檢驗合格證等證明)。檢驗和驗收標(biāo)準(zhǔn):應(yīng)以廠商的標(biāo)準(zhǔn)為準(zhǔn)。貨物運(yùn)抵用戶現(xiàn)場后,用戶方應(yīng)在2日內(nèi)組織驗收,并簽署驗收意見。)綜上幾點,我方在質(zhì)保期內(nèi)將提供以下幾種類型的技術(shù)服務(wù):電話支持服務(wù):提供7×24小時電話支持服務(wù)。遠(yuǎn)程服務(wù):遠(yuǎn)程服務(wù)可包括傳真、電子郵件、遠(yuǎn)程檢測、公司網(wǎng)站等方式提供咨詢、診斷、分析和排除故障?,F(xiàn)場響應(yīng)服務(wù):半小時響應(yīng),6小時內(nèi)到達(dá)產(chǎn)品交付地點(旺峰科技攀枝花辦事處)進(jìn)行故障定位及維修。如果問題不能通過電話解決,遠(yuǎn)恒至盛會立即派出相關(guān)人6小時內(nèi)到達(dá)現(xiàn)場為用戶解決問題。緊急服務(wù):對緊急故障、重大節(jié)日、重要活動進(jìn)行現(xiàn)場技術(shù)保障與支持服務(wù),并對關(guān)鍵部件提供備件服務(wù)。當(dāng)故障對系統(tǒng)產(chǎn)生影響,造成個別業(yè)務(wù)停頓或者影響系統(tǒng)正常運(yùn)行,甚至造成系統(tǒng)無法運(yùn)行或癱瘓,我客服中心會在電話了解具體情況尋求解決方法的同時,派出骨干技術(shù)人員和資深維護(hù)人員一同趕往現(xiàn)場處理,并且召開緊急會議,制定對策和解決方案,盡快解決問題,恢復(fù)系統(tǒng),并對關(guān)鍵部件提供備件服務(wù)。定期巡查服務(wù):我們提供的全方位服務(wù),包括對用戶的定期巡查制度每月派出系統(tǒng)技術(shù)服務(wù)工程師到達(dá)用戶現(xiàn)場,采用先進(jìn)的檢測與分析工具對系統(tǒng)進(jìn)行診斷,提出系統(tǒng)優(yōu)化建議與措施。技術(shù)升級服務(wù):我們終身為用戶系統(tǒng)進(jìn)行免費(fèi)升級,可以保證客戶擁有最新技術(shù)。提前通知服務(wù):我們推出的提前通知服務(wù)是把我們剛剛發(fā)現(xiàn)的關(guān)鍵問題或軟件提前告知。提前通知服務(wù)在客戶遇到問題之前便可提供解決方案。注:質(zhì)量期內(nèi)維修服務(wù)的質(zhì)量保障。我公司提供保修期內(nèi),維修服務(wù)的質(zhì)量保障措施:在保修期間,如故障產(chǎn)品的維修周期超過5個工作日,我公司為用戶提供相同型號或性能相近的備用產(chǎn)品使用;同一產(chǎn)品出現(xiàn)兩次故障,我公司更換成新的產(chǎn)品。在保修期內(nèi)更換的任何零配件,必須是其原產(chǎn)品廠家生產(chǎn)的。所有的替代零配件必須是新的未使用和未經(jīng)修復(fù)的,除非最終用戶提供書面許可,不可使用其他替代配件。質(zhì)保期外的服務(wù)承諾:為了保證用戶的業(yè)務(wù)穩(wěn)定運(yùn)行,保障關(guān)鍵設(shè)備質(zhì)量不影響業(yè)務(wù)穩(wěn)定運(yùn)行。在質(zhì)保期滿后,我公司能為用戶提供技術(shù)支持服務(wù)。仍然保留本項目的技術(shù)支持小組,提供原廠認(rèn)證的CCNPCCIE技術(shù)人員現(xiàn)場支持和技術(shù)服務(wù)。向用戶提供每月1次的免費(fèi)現(xiàn)場巡檢服務(wù),并提交巡檢報告和技術(shù)優(yōu)化建議。其他服務(wù)。在質(zhì)保期外的服務(wù),我方只收取一定的成本費(fèi)用。注:質(zhì)量期外維修服務(wù)的質(zhì)量保障在質(zhì)保期外,維修服務(wù)的質(zhì)量保障措施:在保修期外更換的任何零配件,必須是其原產(chǎn)品廠家生產(chǎn)的。所有的替代零配件必須是新的未使用和未經(jīng)修復(fù)的,除非最終用戶提供書面許可,我方

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論