-.zC控制、保護(hù)和測(cè)量Control,ProtectionandMetering機(jī)組局部UnitPart1發(fā)變組保護(hù)A柜G/TUnitProtectionPanelARCS-985A面Set11南瑞繼保
NARI-RELAYS2發(fā)變組保護(hù)B柜G/TUnitProtectionPanelBRCS-985A面Set11南瑞繼保
NARI-RELAYS3發(fā)變組保護(hù)C柜G/TUnitProtectionPanelCRCS-974AG2,2臺(tái)RCS-974AG2,Total2面Set11南瑞繼保
NARI-RELAYS4機(jī)組測(cè)量屏UnitMeteringPanel**國(guó)力變送器HARBINGUOLITransmitter面Set115機(jī)組電度表屏UnitWatt-hourMeterPanelDTSD341-9DS,3臺(tái)DTSD341-9DS,Total3面Set116機(jī)組故障錄波屏UnitFaultRecorderPanelFGL-3000C面Set11**國(guó)力HARBINGUOLI7發(fā)電機(jī)轉(zhuǎn)子匝間監(jiān)測(cè)屏GeneratorRotorTurn-to-turnMonitoringPanelFZGL-10面Set11**國(guó)力HARBINGUOLI8機(jī)組同期屏UnitSynchronizationPanelSID-2CM,SID-2*-A-4面Set11**智能
SHENZHENZHINENG9機(jī)組快切屏UnitABTPanelSID-8BT-A,2臺(tái)SID-8BT-A,Total2面Set11**智能
SHENZHENZHINENG5.升壓站網(wǎng)絡(luò)計(jì)算機(jī)監(jiān)控系統(tǒng)5.Boosterstationnetworkputermonitoringsystem5.1網(wǎng)絡(luò)控制5.1networkcontrol網(wǎng)絡(luò)計(jì)算機(jī)監(jiān)控系統(tǒng)采用分層分布式網(wǎng)絡(luò)機(jī)構(gòu),分為站控層和間隔層。站控層設(shè)置兩臺(tái)操作員站、一臺(tái)工程師站兼資料管理機(jī)和一臺(tái)五防站,布置在網(wǎng)控樓的網(wǎng)絡(luò)控制室內(nèi)。并設(shè)一臺(tái)集控室監(jiān)視站,布置在集控樓的集控室內(nèi)。Networkputermonitoringsystemusinglayereddistributednetwork,dividedintocontrollayerofthestationandspacer-layer.Controllayerofthestationisprovidedwithtwooperatorstations,oneengineeringanddatamanagementsation,onefiveanti-workstation,theseequipmentsarearrangedinnetworkcontrolroomofNCB.Andonecontrolroommonitoringstationisalsoprovided,whichisarrangedincentercontrolroomofCCB.本工程150kV第一串~第四串測(cè)控、150kV線路測(cè)控、150kV母線設(shè)備測(cè)控、150kV城鎮(zhèn)變測(cè)控保護(hù)以及線路保護(hù)等間隔層設(shè)備布置在網(wǎng)控樓的繼電器室內(nèi)。并設(shè)置一套遠(yuǎn)動(dòng)主站、一臺(tái)系統(tǒng)保護(hù)管理機(jī)、兩套效勞器和一套GPS對(duì)時(shí)系統(tǒng)。Inthisproject,thefirst-thefourth150kVstringmonitorandcontrol,150kViningandoutgoinglinemonitorandcontrol,150kVbusequipmentmonitorandcontrol,150kVTFTmonitor,controlandprotection,aswellaslineprotectionetcequipmentsonspacer-layerarearrangedinrelayroomofNCB.Aremotemasterstation,asystemprotectionmanagement,twostationunitsandaGPStimesynchronizationsystemarealsoprovided.150kV升壓站為3/2斷路器接線,上4個(gè)完整串,升壓站電氣設(shè)備可在以下控制地點(diǎn)實(shí)現(xiàn):站控層、微機(jī)五防模擬屏和操作機(jī)構(gòu)箱。與發(fā)變組進(jìn)線相關(guān)的4個(gè)斷路器DCS也能控制。150kVswitchyardadopts3/2circuitbreakerwiring,fourpletestringsareprovided,theelectricalequipmentin150kVswitchyardcanbecontrolledbyundermentionedlocation:operatingstation,puterfiveanti-simulationscreenandoperatingmechanismbo*.CircuitbreakerofG/TunitiningcanbecontrolledbyDCS.升壓站內(nèi)設(shè)置一臺(tái)城鎮(zhèn)變和20kV地區(qū)負(fù)荷配電裝置,這些設(shè)備的監(jiān)控也納入NCS。ATFTand20kVdistrictloadswitchgearareprovidedinswitchyard,monitoringandcontroloftheseequipmentsisalsoincludedinNCS.5.2網(wǎng)絡(luò)同期5.2networksynchronizationNCS系統(tǒng)具有單相〔A相〕同期功能,除發(fā)變組進(jìn)線相關(guān)的4個(gè)斷路器,其他150kV任一斷路器,同期電壓按“近區(qū)優(yōu)先〞原則選擇由裝置RCS-9664實(shí)現(xiàn)。NCSsystemhassingle-phase(PhaseA)synchronizationfunction,e*ceptfourcircuitbreakersrelatedwithG/Tunitining,anyother150kVcircuitbreakerisselectedbydeviceRCS-9664accordingtosynchronousvoltageintheprincipleof"nearzonepriority".5.3操作閉鎖5.3operationlockingNCS站控層設(shè)五防工作站,軟件上可實(shí)現(xiàn)整個(gè)150kV開(kāi)關(guān)站斷路器和隔離開(kāi)關(guān)遠(yuǎn)方操作閉鎖功能。通過(guò)電編碼鎖對(duì)斷路器、隔離開(kāi)關(guān)實(shí)現(xiàn)防誤入間隔及間隔層〔斷路器〕和就地機(jī)構(gòu)箱上的操作閉鎖。NCSstationcontrollayerisprovidedwithfive-preventionworkstation,softwaremayrealizeremoteoperationlockingfunctionbetweencircuitbreakerandisolatingswitchinthewhole150kVswitchyard.Falseentryprotection,operationlockingonspacer-layer(circuitbreaker)andlocalmechanismbo*mayberealizedforcircuitbreaker,isolatingswitchthroughelectriccodelock.5.4遠(yuǎn)動(dòng)功能5.4remotefunctionNCS系統(tǒng)設(shè)有冗余的遠(yuǎn)開(kāi)工作站,數(shù)據(jù)采集與監(jiān)控系統(tǒng)共享,遠(yuǎn)開(kāi)工作站負(fù)責(zé)與當(dāng)?shù)卣{(diào)度實(shí)時(shí)傳送遠(yuǎn)動(dòng)信息,并實(shí)現(xiàn)AGC功能。本工程在集控樓*1電子設(shè)備間設(shè)*1發(fā)變組進(jìn)線測(cè)控柜;在集控樓*2電子設(shè)備間設(shè)*2發(fā)變組進(jìn)線測(cè)控柜。進(jìn)線測(cè)控柜內(nèi)含各機(jī)組的發(fā)電機(jī)出線及主變高壓側(cè)遠(yuǎn)動(dòng)信息采集單元,并采用多芯光纜與網(wǎng)控樓繼電器室內(nèi)的主站及遠(yuǎn)開(kāi)工作站連接。數(shù)模轉(zhuǎn)換模塊將收到的AGC數(shù)字信號(hào)轉(zhuǎn)換成4~20mA模擬量后送到熱工CGB01柜完成調(diào)度對(duì)機(jī)組的AGC調(diào)節(jié)。NCSsystemisprovidedwithredundantremoteworkstation,whichsharedataacquisitionwithmonitoringsystem,remoteworkstationrealizestransmissionofremoteinformationwithnativedispatchinrealtimeandrealizesAGCfunction.Intheproject,NCSpanelfor*1G/Tunitisarrangedin*1electricalequipmentroomofCCB;NCSpanelfor*2G/Tunitisarrangedin*2electricalequipmentroomofCCB.NCSpanelforG/TunitcontainsgeneratoroutgoinglineofeachunitandMThighvoltagesideremoteinformationacquisitionunit,adoptsmulticoreopticalcabletoconnectwithmasterstationandremoteworkstationinrelayroomofNCB.Digital-analogconversionmoduleconvertsthereceivedAGCdigitalsignalinto4-20mAanalogquantity,thensendstoI&C5.5測(cè)量5.5measurementNCS系統(tǒng)采用交流采樣方式,將CT、PT二次回路電流和電壓輸入測(cè)控單元,按采樣周期定時(shí)采集處理數(shù)據(jù),并可計(jì)算獲得有功功率、無(wú)功功率、頻率等,采樣精度可達(dá)0.2%。對(duì)不能實(shí)現(xiàn)交流采集的信息采用直流采樣。NCSsystemadoptsACsamplingmode,inputsCT,PTsecondarycircuitcurrentandvoltageintomeasurementandcontrolunit,acquiresandprocessesdatatimelyaspersamplingperiod,andmaycalculateactivepower,reactivepower,frequencyetc,samplingaccuracycouldreach0.2%.FortheinformationunsuitableforACacquisition,DCsamplingisadopted.5.6GPS對(duì)時(shí)系統(tǒng)5.6GPStimesynchronizationsystem在網(wǎng)控樓網(wǎng)絡(luò)繼電器室設(shè)GPS主時(shí)鐘系統(tǒng),為網(wǎng)控樓內(nèi)的設(shè)備提供GPS對(duì)時(shí)信號(hào)。在集控樓*1和*2電子設(shè)備間分別設(shè)置GPS擴(kuò)展設(shè)備,用于集控樓內(nèi)的單元機(jī)組設(shè)備GPS對(duì)時(shí)。GPSmasterclocksystemisarrangedinnetworkrelayroomofNCBtoprovideGPStimingsignalforequipmentsinNCB;GPSe*tensionequipmentisarrangedin*1and*2electricalequipmentroomofCCBrespectivelyforGPStimingoftheunitequipmentsinCCB.5.7組柜方案5.7groupingscheme納入NCS系統(tǒng)供貨的盤(pán)柜有:150kV第一~四串測(cè)控柜;150kV進(jìn)出線測(cè)控柜;150kV母線測(cè)控柜;150kV線路和城鎮(zhèn)變測(cè)控柜;公用測(cè)控柜;保護(hù)管理機(jī)柜;遠(yuǎn)開(kāi)工作站柜;網(wǎng)控交換機(jī)柜1;網(wǎng)控交換機(jī)柜2;效勞器屏以上設(shè)備布置在網(wǎng)絡(luò)繼電器室內(nèi)。150kV*1發(fā)變組進(jìn)線測(cè)控柜;集控樓網(wǎng)關(guān)機(jī)柜以上設(shè)備布置在集控樓*1電子設(shè)備間內(nèi)。150kV*2發(fā)變組進(jìn)線測(cè)控柜以上設(shè)備布置在集控樓*2電子設(shè)備間內(nèi)。20kV配電間以太網(wǎng)交換機(jī)、通訊管理機(jī)柜以上設(shè)備布置在20kV配電間。PanelsincludedinNCSsystemsupplyinclude:NCSPanelfortheFirst~FourthString;NCSPanelfor150kVIningandOutgoingLine;NCSPanelfor150kVBus;NCSPanelforTransmissionLineandTFT;NCSPanelformonDevice;NCSPanelforProtectionManagement;NCSPanelforRomoteWorkstation;NCSPanelforEthernetSwitch1;NCSPanelforEthernetSwitch2;NCSPanelforStationUnit,Theaboveequipmentsarearrangedinnetworkrelayroom.NCSPanelfor*1G/TUnit;NCSPanelforGatewayofCentralControlTheaboveequipmentsarearrangedin*1electricalequipmentroomofCCB.NCSPanelfor*2G/TUnit;Theaboveequipmentisarrangedin*2electricalequipmentroomofCCB.20kVPanelforProtocolConversionTheaboveequipmentisarrangedin20kVswitchroom.F網(wǎng)絡(luò)監(jiān)控系統(tǒng)NCSSystem1遠(yuǎn)開(kāi)工作站柜
NCSPanelforRomoteWorkstation遠(yuǎn)動(dòng)通訊裝置RCS-9698H1臺(tái)
GPS對(duì)時(shí)裝置RCS-9785C1臺(tái)OPT1031個(gè),光纖終端盒3個(gè)
RemoteTerminalUnitRCS-9698H1SetGPSSynchronizedClockRCS-9785C1Set
OPT1031piece,F(xiàn)iberOpticHub3piece面set1南瑞繼保NARI-RELAYS2保護(hù)管理機(jī)柜
NCSPanelforProtectionManagement以太網(wǎng)交換機(jī)PCS-9882C1臺(tái)
通訊管理機(jī)RCS-9798A1臺(tái)
研華工控機(jī)1臺(tái),直流電源切換裝置RCS-96651臺(tái)
EthernetSwitchPCS-9882C1Set
ProtocolConverterUnitRCS-9798A1Set
YanhuaIPC1SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS3網(wǎng)控交換機(jī)柜1
NCSPanelforEthernetSwitch1以太網(wǎng)交換機(jī)PCS-9882C4臺(tái),光纖終端盒2個(gè)直流電源切換裝置RCS-96651臺(tái)
EthernetSwitchPCS-9882C4Set,FiberOpticHub2pieceDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS4網(wǎng)控交換機(jī)柜2
NCSPanelforEthernetSwitch2以太網(wǎng)交換機(jī)PCS-9882C4臺(tái),光纖終端盒2個(gè)直流電源切換裝置RCS-96651臺(tái)
EthernetSwitchPCS-9882C4Set,FiberOpticHub2pieceDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS5150kV第一串測(cè)控柜
NCSPanelfortheFirstString斷路器測(cè)控裝置RCS-9705C3臺(tái)
同期電壓切換裝置RCS-96641臺(tái)直流電源切換裝置RCS-96651臺(tái)
CBControlUnitRCS-9705C3Set
Sync.VoltageTransferRCS-96641SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS6150kV第二串測(cè)控柜
NCSPanelfortheSecondString斷路器測(cè)控裝置RCS-9705C3臺(tái)
同期電壓切換裝置RCS-96641臺(tái)直流電源切換裝置RCS-96651臺(tái)
CBControlUnitRCS-9705C3Set
Sync.VoltageTransferRCS-96641SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS7150kV第三串測(cè)控柜
NCSPanelfortheThirdString斷路器測(cè)控裝置RCS-9705C3臺(tái)
同期電壓切換裝置RCS-96641臺(tái)直流電源切換裝置RCS-96651臺(tái)
CBControlUnitRCS-9705C3Set
Sync.VoltageTransferRCS-96641SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS8150kV第四串測(cè)控柜
NCSPanelfortheFourthString斷路器測(cè)控裝置RCS-9705C3臺(tái)
同期電壓切換裝置RCS-96641臺(tái)直流電源切換裝置RCS-96651臺(tái)
CBControlUnitRCS-9705C3Set
Sync.VoltageTransferRCS-96641SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS9150kV進(jìn)出線測(cè)控柜
NCSPanelfor150kVIningandOutgoingLine測(cè)控裝置RCS-9709C3臺(tái)直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9709C3SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS10150kV母線測(cè)控柜
NCSPanelfor150kVBus測(cè)控裝置RCS-9702C4臺(tái)直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9702C4SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS11150kV線路和城鎮(zhèn)變測(cè)控柜
NCSPanelforTransmissionLineandTFT測(cè)控裝置RCS-9709C2臺(tái)
測(cè)控裝置RCS-9703C1臺(tái)直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9709C2Set
ControlUnitRCS-9703C1SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS12公用測(cè)控柜
NCSPanelformonDevice測(cè)控裝置RCS-9702C3臺(tái)
通訊管理機(jī)RCS-9784A1臺(tái)溫度變送器PT1001臺(tái),直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9702C3Set
ProtocolConverterUnitRCS-9784A1SetTemperatureTransmitterPT1001SetDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS13集控樓網(wǎng)關(guān)機(jī)柜
NCSPanelforGatewayofCentralControlBuilding以太網(wǎng)交換機(jī)PCS-9882C2臺(tái)
通訊管理機(jī)RCS-9784A1臺(tái),光纖終端盒2個(gè)直流電源切換裝置RCS-96651臺(tái)
EthernetSwitchPCS-9882C2Set
ProtocolConverterUnitRCS-9784A1Set
FiberOpticHub2pieceDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS14150kV*1發(fā)變組進(jìn)線測(cè)控柜
NCSPanelfor*1G/TUnit
測(cè)控裝置RCS-9708C1臺(tái),測(cè)控裝置RCS-9709C1臺(tái)
GPS對(duì)時(shí)裝置RCS-9785E1臺(tái)
OPT1031個(gè),光纖終端盒1個(gè)直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9708C1Set,ControlUnitRCS-9709C1Set
GPSSynchronizedClockRCS-9785E1Set
OPT1031piece,F(xiàn)iberOpticHub1pieceDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS15150kV*2發(fā)變組進(jìn)線測(cè)控柜
NCSPanelfor*2G/TUnit
測(cè)控裝置RCS-9708C1臺(tái),測(cè)控裝置RCS-9709C1臺(tái)
GPS對(duì)時(shí)裝置RCS-9785E1臺(tái)
光纖終端盒1個(gè)直流電源切換裝置RCS-96651臺(tái)
ControlUnitRCS-9708C1Set,ControlUnitRCS-9709C1Set
GPSSynchronizedClockRCS-9785E1Set
FiberOpticHub1pieceDCSupplyTransferSwitchRCS-96651Set面set1南瑞繼保NARI-RELAYS16操作員工作站
NCSOperatorHMIDELLCPU:2.4GHz雙核;內(nèi)存:2G;硬盤(pán):120G;DVD光驅(qū):52倍速;22寸液晶彩顯;分辨率1800×1440;以太網(wǎng)接口2個(gè)。
DELLCPU:2.4GHzDual-Core;Memory:2G;Harddisk:120G;DVDDrive:52speed;22"LED;Resolution1800×1440;
InterfaceofEthernet2piece。臺(tái)set2南瑞繼保NARI-RELAYS17集控室監(jiān)視站
ControlRoomMonitoringStationDELLCPU:2.4GHz雙核;內(nèi)存:2G;硬盤(pán):120G;DVD光驅(qū):52倍速;22寸液晶彩顯;分辨率1800×1440;以太網(wǎng)接口2個(gè)。
DELLCPU:2.4GHzDual-Core;Memory:2G;Harddisk:120G;DVDDrive:52speed;22"LED;Resolution1800×1440;
InterfaceofEthernet2piece。臺(tái)set1南瑞繼保NARI-RELAYS18工程師工作站兼資料管理機(jī)
NCSEngineeringandDataManagementSationDELLCPU:2.4GHz雙核;內(nèi)存:2G;硬盤(pán):120G;DVD光驅(qū):52倍速;22寸液晶彩顯;分辨率1800×1440;以太網(wǎng)接口2個(gè)。
DELLCPU:2.4GHzDual-Core;Memory:2G
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年高新技術(shù)企業(yè)委托招聘與研發(fā)團(tuán)隊(duì)構(gòu)建合同3篇
- 2025年食材配送企業(yè)冷鏈物流服務(wù)合同3篇
- 2025版共享單車運(yùn)維服務(wù)與用戶租賃合同范本3篇
- 2025年度旅游汽車租賃及戶外活動(dòng)策劃合同4篇
- 二零二五版高端養(yǎng)殖牛場(chǎng)合伙經(jīng)營(yíng)合同3篇
- 二零二五版科技創(chuàng)新園區(qū)黨建資源共享合作協(xié)議3篇
- 2025年度煤礦設(shè)備采購(gòu)及安裝服務(wù)二零二五版合同4篇
- 鄭州城建職業(yè)學(xué)院《中國(guó)民事訴訟法》2023-2024學(xué)年第一學(xué)期期末試卷
- 2024藥品采購(gòu)及質(zhì)量管理體系認(rèn)證合同3篇
- 2025年度市政工程承攬合同建設(shè)施工合同模板4篇
- 課題申報(bào)書(shū):GenAI賦能新質(zhì)人才培養(yǎng)的生成式學(xué)習(xí)設(shè)計(jì)研究
- 駱駝祥子-(一)-劇本
- 全國(guó)醫(yī)院數(shù)量統(tǒng)計(jì)
- 《中國(guó)香文化》課件
- 2024年醫(yī)美行業(yè)社媒平臺(tái)人群趨勢(shì)洞察報(bào)告-醫(yī)美行業(yè)觀察星秀傳媒
- 第六次全國(guó)幽門(mén)螺桿菌感染處理共識(shí)報(bào)告-
- 2024-2030年中國(guó)商務(wù)服務(wù)行業(yè)市場(chǎng)現(xiàn)狀調(diào)查及投資前景研判報(bào)告
- 高一英語(yǔ)必修一試卷(含答案)(適合測(cè)試)
- 中國(guó)的世界遺產(chǎn)智慧樹(shù)知到期末考試答案2024年
- 中國(guó)綠色食品市場(chǎng)調(diào)查與分析報(bào)告
- 手衛(wèi)生依從性調(diào)查表
評(píng)論
0/150
提交評(píng)論