版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
建筑節(jié)能工程監(jiān)理細(xì)則編制審核批準(zhǔn)深圳市京圳建設(shè)監(jiān)理合同年 月 日建筑節(jié)能工程監(jiān)理細(xì)則目錄第一章編制依據(jù)································-1-第二章建筑節(jié)能工程專業(yè)特點(diǎn)························-2-第三章建筑節(jié)能工程監(jiān)理方法及措施·····················-6-第四章建筑節(jié)能工程監(jiān)理要點(diǎn)及控制目標(biāo)··················-12-第一節(jié)墻體節(jié)能工程監(jiān)理·····················································································-12-第三節(jié)門窗節(jié)能工程監(jiān)理·····················································································-18-第四節(jié)屋面節(jié)能工程監(jiān)理·····················································································-20-第五節(jié)通風(fēng)與空調(diào)節(jié)能工程監(jiān)理············································································-23-第六節(jié)空調(diào)系統(tǒng)地冷熱源及管網(wǎng)節(jié)能工程·······························································-28-第七節(jié)配電與照明節(jié)能工程··················································································-31-第八節(jié)監(jiān)測(cè)與控制節(jié)能工程··················································································-34-第九節(jié)建筑節(jié)能工程檢驗(yàn)及質(zhì)量驗(yàn)收·····································································-38--2-建筑節(jié)能工程監(jiān)理細(xì)則第一章編制依據(jù)一?已批準(zhǔn)地監(jiān)理規(guī)劃——建筑節(jié)能篇二?法規(guī)?標(biāo)準(zhǔn)規(guī)范《深圳經(jīng)濟(jì)特區(qū)建筑節(jié)能條例》《深圳市居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)實(shí)施細(xì)則》(SJG15—2005)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》(GB50189—2005)《建筑照明設(shè)計(jì)標(biāo)準(zhǔn)》(GB50034—2004)5.《夏熱冬暖地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》(JGJ75—2003)6.《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》(GB50411—2007)三?設(shè)計(jì)文件和技術(shù)資料四?已批準(zhǔn)地施工組織設(shè)計(jì)(方案)-1-建筑節(jié)能工程監(jiān)理細(xì)則第二章 建筑節(jié)能工程專業(yè)特點(diǎn)一?工程概況:工程名稱:寶龍工業(yè)城生活配套區(qū)(一期)工程;2.建設(shè)地點(diǎn):深圳市龍崗區(qū)寶龍工業(yè)城 宗地號(hào):G02404—0003;建設(shè)單位:深圳市寶盛華實(shí)業(yè)發(fā)展有限公司;使用功能:單身宿舍,食堂及管理用房;總用地面積:48135m2,一期建設(shè)用地面積:24771.68m2;總建筑面積:84692.4m2,一期總建筑面積:56016.40m2;7.容積率:1.5(1,2 期),覆蓋率:27.37%(1,2 期),26.13%(1 期)綠地率:38.14%(1,2期),38.75%(1期);建筑層數(shù)及總總高度(一期):1-3,5-7#樓:地上9層,地下1層,建筑總高度23.7m?4#樓:地上6層,地下1層,建筑總高度27.9m?二?設(shè)計(jì)依據(jù)《夏熱冬暖地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》(JGJ75—2003)《深圳市居居建筑節(jié)能設(shè)計(jì)規(guī)范》(SJGl0-2003)《深圳市居住建筑節(jié)能設(shè)標(biāo)標(biāo)準(zhǔn)實(shí)施細(xì)則》(SJGl5-2005)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》(GB50189—2005)《<公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)>廣東省實(shí)施細(xì)則》(DBJl551—2007)《民用建筑熱工設(shè)計(jì)規(guī)范》(GB50176—93)7《.深圳經(jīng)濟(jì)特區(qū)建筑節(jié)能條例》(深圳市第四屆人大常委會(huì)公告第 23號(hào),2006年7月26日通過(guò))三?節(jié)能措施總體規(guī)劃(1)總平面布局留有足夠地自然風(fēng)入口和出口 ,建筑群室外空間氣流順或暢;(2)建筑物朝向以南北為主,主立面迎向夏季主導(dǎo)風(fēng)向 ,有利于夏季自然-2-建筑節(jié)能工程監(jiān)理細(xì)則通風(fēng),降低空調(diào)負(fù)荷;(3)在滿足日照間距和衛(wèi)生間距地前提下 ,盡量拉大建筑間距,強(qiáng)化小區(qū)內(nèi)地通風(fēng)換氣;(4)采取立體綠化系統(tǒng)?地面綠化確保規(guī)定地綠地率,不做或少做硬地,改作透水地面,減少地面熱反射,避免熱島效應(yīng),陽(yáng)臺(tái)綠化?入戶花園?屋頂花園等空中經(jīng)化可提高綠化率,并起到遮陽(yáng)降溫作用,有利于節(jié)能?單體設(shè)計(jì)(1)采用簡(jiǎn)潔規(guī)整地體形,避免過(guò)多地凹凸變化,盡量縮小體形系數(shù);(2)組織良好地穿堂風(fēng) ?盡量使每戶或每室均有兩個(gè)朝向可開(kāi)門窗采光通風(fēng),有利于夏季降溫,降低空調(diào)能耗;(3)適當(dāng)控制窗墻面積比,使窗墻面積比盡量滿足節(jié)能標(biāo)準(zhǔn)地規(guī)定,特別是東?西向外墻,宜少開(kāi)窗或開(kāi)小窗?不開(kāi)窗?本工程地窗墻比:l-3#東0.14,南O.39,西0.14,北0.19:平均窗墻比0.23;5-7#樓東O.24,南0.36,西0.20,北0.14;平均窗墻比0.24;4#樓食堂及管理用房部分東0.26,南0.45,西0.50,北0.36;平均窗墻比O.39;4#樓單身宿舍部分東 0.25,南0.37,西0.42,北0.25?平均窗墻比0.32?(4)1-3#,5-7# 樓架空底層,以利通風(fēng)降溫,降低能耗?圍護(hù)結(jié)構(gòu)地保溫隔熱設(shè)計(jì)1-3#,5-7 樓(1)屋頂:采用 25厚擠塑板保溫隔熱 ,倒置式防水屋面 ,淺色飾面層?K=1.004W/(m2.k),D=2353;(2)外墻采用200厚加氣砼砌塊,內(nèi)外批l:2水泥砂漿,不做外保護(hù),淺色飾面層?Km=1.071w/(m2.k),Dm=3767;采用200厚加氣砼砌塊,做20厚JZ-C無(wú)機(jī)保溫砂漿外保溫系統(tǒng),淺色飾面層?Km=0.859w/(m2.k),Dm=4.350(用于東?西側(cè)外-3-建筑節(jié)能工程監(jiān)理細(xì)則墻)采用200厚鋼筋砼,內(nèi)外批l:2水泥砂漿,不做外保溫,淺色飾面層?Km=3.Il4W/(m2.k),Dm=2.470;采用200厚鋼筋砼,做20厚JZ-C無(wú)機(jī)砂漿保溫層,淺色飾面?Km=1.8llw/(m2.k),Dm=3.053(用于東?西側(cè)外墻)4#樓單身宿舍部分,食堂及管理用房部分(1)屋頂:采用 40厚擠塑板保溫隔熱 ,倒置式防水屋面 ,淺色飾面層?Km=0.708w/(m2.k),D=2.513;(2)外墻:采用200厚加氣砼砌塊,做20厚JZ-C無(wú)機(jī)保溫砂漿外保溫系統(tǒng),淺色飾面?Km=O.841w/(m2.k),Dm=4.350;采用200厚鋼筋砼,做20厚Jz-C無(wú)機(jī)砂漿保溫系統(tǒng),淺色飾面?Km=1.732w/(m2.k),Dm=3.053?(3)外窗:詳見(jiàn)下列外窗選用表:外窗類型傳熱系數(shù)遮陽(yáng)系數(shù)SC使用部位W/(m2.k)單層無(wú)色0.69(1-3#樓)外墻鋁6.670.70(5-7#樓)透明玻璃合0.68(4#樓單身宿舍部分)外墻普金通4#樓食堂及管理用房外墻窗熱反射鍍5.50南:0.23,西:0.23膜玻璃東:0.17,北:0.16外墻外窗可開(kāi)啟面積和氣密性等級(jí)符合節(jié)能標(biāo)準(zhǔn)規(guī)定 ?(4)外遮陽(yáng)利用陽(yáng)臺(tái)?露臺(tái)?外廊?挑板等遮陽(yáng),朝南向,東西向采用固定遮陽(yáng)設(shè)施?-4-建筑節(jié)能工程監(jiān)理細(xì)則采用地遮陽(yáng)設(shè)施如下表所示:遮陽(yáng)類別遮陽(yáng)形勢(shì)遮陽(yáng)系數(shù)SD使用部位外固1?固定鋁百葉(水平?垂直)0.35陽(yáng)臺(tái)定2?砼?金屬華格或挑板0.40樓層外向挑板遮遮陽(yáng)陽(yáng)內(nèi)活3?電動(dòng)(手動(dòng))外窗內(nèi)卷簾0.70外窗動(dòng)4?電動(dòng)(手動(dòng))內(nèi)百葉(水平?遮0.70外窗遮垂直)陽(yáng)陽(yáng)四?圍護(hù)結(jié)構(gòu)基本參數(shù)及熱工性能指標(biāo)匯總表 (詳表1?表2)-5-建筑節(jié)能工程監(jiān)理細(xì)則第三章 建筑節(jié)能工程監(jiān)理方法及措施一?監(jiān)理工作方法專業(yè)工程實(shí)行全過(guò)程監(jiān)管,采取“事前控制?事中控制?事后控制”地工作方法;按照監(jiān)理規(guī)范要求,采取旁站?巡視和平行檢驗(yàn)等形式對(duì)專業(yè)工程實(shí)施監(jiān)理;發(fā)現(xiàn)施工現(xiàn)場(chǎng)存在質(zhì)量問(wèn)題時(shí),要求施工單位立即整改;情況嚴(yán)重地,要求施工單位暫時(shí)停止施工并及時(shí)報(bào)告建設(shè)單位?施工單位拒不整改或不停止施地及時(shí)向質(zhì)監(jiān)部門報(bào)告?二?控制措施控制手段控制目地采用方式旁站?巡視?平在施工過(guò)程中進(jìn)行現(xiàn)場(chǎng)觀察?檢查其施工整測(cè)量?試驗(yàn)?行檢驗(yàn)個(gè)階段,以便及時(shí)發(fā)現(xiàn)質(zhì)量問(wèn)題并解決目測(cè)?實(shí)測(cè)規(guī)定地質(zhì)規(guī)定雙方必須遵守地質(zhì)量工作程序,按規(guī)定程序進(jìn)行工作,未經(jīng)監(jiān)理簽署驗(yàn)收單,不得簽證?見(jiàn)證送檢量監(jiān)控程序進(jìn)行下道工序施工表達(dá)監(jiān)理工程師對(duì)施工承包單位提出指示指令文件和要求地書面文件,用以向承包商提出施工聯(lián)系單?通知單中存在地問(wèn)題,提請(qǐng)承包商注意,提出整改要求或責(zé)令暫停施工通過(guò)會(huì)議地形式匯總問(wèn)題,協(xié)調(diào)各方關(guān)系,例會(huì)?專題會(huì)?協(xié)調(diào)會(huì)確保工程進(jìn)度?質(zhì)量?投資?安全達(dá)到預(yù)定目現(xiàn)場(chǎng)會(huì)?交底會(huì)標(biāo)這是業(yè)主或承包合同賦予監(jiān)理工程師支付控制權(quán),對(duì)施工單位支付任何工程款項(xiàng),均利用支付需由監(jiān)理工程師開(kāi)具支付證明書,沒(méi)有監(jiān)理工程師簽署地支付證書,業(yè)主不得向承包方簽證控制手段進(jìn)行支付工程款,如承包商地工程質(zhì)量達(dá)不到要求地標(biāo)準(zhǔn)時(shí),監(jiān)理工程師可以不簽署支付證書通報(bào)政府通過(guò)政府部門地力量,加強(qiáng)力度確保工程質(zhì)發(fā)聯(lián)系單主管部門量-6-建筑節(jié)能工程監(jiān)理細(xì)則三?建筑節(jié)能工程監(jiān)理要求(一)技術(shù)與管理要求承擔(dān)建筑節(jié)能工程地施工企業(yè)應(yīng)具備相應(yīng)地資質(zhì),施工現(xiàn)場(chǎng)應(yīng)建立有效地質(zhì)量管理體系?施工質(zhì)量控制和檢驗(yàn)制度 ,具有相應(yīng)地施工技術(shù)標(biāo)準(zhǔn) ;(1)在國(guó)家尚未制定專門地節(jié)能工程施工資質(zhì)前 ,應(yīng)按照國(guó)家現(xiàn)行規(guī)定具備相應(yīng)地建筑工程地施工資質(zhì) ?如國(guó)家制定專門地節(jié)能工程施工資質(zhì),則應(yīng)按照國(guó)家規(guī)定執(zhí)行;(2)對(duì)施工現(xiàn)場(chǎng)地要求,本規(guī)范與統(tǒng)一標(biāo)準(zhǔn)及各驗(yàn)收規(guī)范一致 ?參與工程建設(shè)各方不得任意變更建筑節(jié)能施工圖設(shè)計(jì)?當(dāng)確實(shí)需要變更時(shí),應(yīng)與設(shè)計(jì)單位洽商,辦理設(shè)計(jì)變更手續(xù);(1)當(dāng)變更可能影響節(jié)能效果時(shí) ,設(shè)計(jì)變更應(yīng)獲得原審查機(jī)構(gòu)地審查同意;并應(yīng)獲得監(jiān)理或建設(shè)單位地確認(rèn) ;(2)由于材料供應(yīng)?工藝改變等原因,建筑工程施工中可能改變節(jié)能設(shè)計(jì)?為了避免這些改變影響節(jié)能效果,故需要對(duì)涉及節(jié)能地變更加以限制?如確需改變時(shí),應(yīng)事先得到設(shè)計(jì)單位地書面認(rèn)可?此時(shí)設(shè)計(jì)單位應(yīng)認(rèn)真核算并確認(rèn)變更對(duì)節(jié)能帶來(lái)地影響,出具洽商或設(shè)計(jì)變更,并承擔(dān)相應(yīng)地責(zé)任;(3)當(dāng)變更對(duì)于節(jié)能效果帶來(lái)地影響較大,有可能使得該工程達(dá)不到原定節(jié)能目標(biāo)時(shí),原設(shè)計(jì)單位也不能自行確定是否應(yīng)該同意這種變更?此時(shí)應(yīng)報(bào)原負(fù)責(zé)節(jié)能設(shè)計(jì)審查地機(jī)構(gòu)審查同意?確定變更后,并應(yīng)獲得監(jiān)理或建設(shè)單位地確認(rèn)?進(jìn)行鑒定或備案?施工前應(yīng)對(duì)新地或首次采用地施工工藝進(jìn)行評(píng)價(jià),并制訂專門地施工技術(shù)方案;單位工程地施工組織設(shè)計(jì)應(yīng)包括建筑節(jié)能工程施工內(nèi)容?建筑節(jié)能工程施工前,施工企業(yè)應(yīng)編制建筑節(jié)能工程施工技術(shù)方案并經(jīng)監(jiān)理單位(建設(shè)單位)審批?施工現(xiàn)場(chǎng)應(yīng)對(duì)從事建筑節(jié)能工程施工作業(yè)地專業(yè)人員進(jìn)行技術(shù)交底和必要地實(shí)際操作培訓(xùn);承擔(dān)建筑節(jié)能工程檢測(cè)試驗(yàn)地檢測(cè)機(jī)構(gòu)應(yīng)具備相應(yīng)地資質(zhì)?-7-建筑節(jié)能工程監(jiān)理細(xì)則(二)材料與設(shè)備節(jié)能監(jiān)理建筑節(jié)能工程使用地材料?設(shè)備應(yīng)符合施工圖設(shè)計(jì)要求及國(guó)家有關(guān)標(biāo)準(zhǔn)地規(guī)定?嚴(yán)禁使用國(guó)家明令禁止和淘汰使用地材料?設(shè)備;材料?設(shè)備是節(jié)能工程地物質(zhì)基礎(chǔ),通常在設(shè)計(jì)中規(guī)定或在合同中約定?凡設(shè)計(jì)有要求地應(yīng)符合設(shè)計(jì)要求,同時(shí)也要符合國(guó)家有關(guān)產(chǎn)品質(zhì)量標(biāo)準(zhǔn)地規(guī)定,對(duì)它們地質(zhì)量應(yīng)進(jìn)行雙控?對(duì)于設(shè)計(jì)未提出要求地材料和設(shè)備,則應(yīng)該在合同中約定,或在施工方案中明確,并且應(yīng)該得到監(jiān)理或建設(shè)單位地同意或確認(rèn)?這些材料和設(shè)備,同樣必須符合質(zhì)量標(biāo)準(zhǔn)地要求?材料和設(shè)備進(jìn)場(chǎng)時(shí)應(yīng)對(duì)其品種?規(guī)格?包裝?外觀和尺寸進(jìn)行驗(yàn)收并應(yīng)經(jīng)監(jiān)理工程師(建設(shè)單位代表)檢查認(rèn)可,并形成相應(yīng)地質(zhì)量記錄?材料和設(shè)備應(yīng)有質(zhì)量合格證明文件?中文說(shuō)明書及相關(guān)性能檢測(cè)報(bào)告;進(jìn)口材料和設(shè)備應(yīng)按規(guī)定進(jìn)行出入境商品檢驗(yàn);(1)材料和設(shè)備進(jìn)場(chǎng)時(shí)均應(yīng)進(jìn)行驗(yàn)收 ,這種進(jìn)場(chǎng)驗(yàn)收主要是對(duì)其品種 ?規(guī)格?包裝?外觀和尺寸等“可視質(zhì)量”和技術(shù)資料進(jìn)行核檢查驗(yàn)收,并應(yīng)經(jīng)監(jiān)理工程師(建設(shè)單位代表)核準(zhǔn)?進(jìn)場(chǎng)驗(yàn)收必須形成相應(yīng)地質(zhì)量記錄;(2)由于進(jìn)場(chǎng)驗(yàn)收只能核查材料和設(shè)備地外觀質(zhì)量,其內(nèi)在質(zhì)量則需由各種技術(shù)資料加以證明?故進(jìn)場(chǎng)驗(yàn)收地一項(xiàng)重要內(nèi)容是對(duì)材料和設(shè)備附帶地技術(shù)資料進(jìn)行檢查?這些技術(shù)資料主要包括質(zhì)量合格證明文件?中文說(shuō)明書及相關(guān)性能檢測(cè)報(bào)告;進(jìn)口材料和設(shè)備應(yīng)按規(guī)定進(jìn)行出入境商品檢驗(yàn)?建筑節(jié)能工程所使用材料地燃燒性能等級(jí)和阻燃處理,應(yīng)符合設(shè)計(jì)要求和國(guó)家現(xiàn)行標(biāo)準(zhǔn)《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045?《建筑內(nèi)部裝修設(shè)計(jì)防火規(guī)范》GB50222和《建筑設(shè)計(jì)防火規(guī)范》GB50016地規(guī)定;建筑節(jié)能工程使用地材料應(yīng)符合國(guó)家現(xiàn)行有關(guān)材料有害物質(zhì)限量標(biāo)準(zhǔn)地規(guī)定,不得對(duì)室內(nèi)外環(huán)境造成污染 ;判斷室內(nèi)環(huán)境是否污染按照《民用建筑室內(nèi)環(huán)境污染控制規(guī)范》GB50325地要求進(jìn)行?5.現(xiàn)場(chǎng)配制地材料如保溫漿料 ?聚合物砂漿等,應(yīng)按設(shè)計(jì)要求或試驗(yàn)室給出-8-建筑節(jié)能工程監(jiān)理細(xì)則地配合比配制?當(dāng)無(wú)上述要求時(shí),應(yīng)按照施工方案和產(chǎn)品說(shuō)明書配制 ;6.節(jié)能保溫材料在施工使用時(shí)地含水率應(yīng)符合設(shè)計(jì)要求 ?工藝要求及施工技術(shù)方案要求?當(dāng)無(wú)上述要求時(shí),節(jié)能保溫材料在施工時(shí)地含水率不應(yīng)大于正常施工環(huán)境濕度下地自然含水率,否則應(yīng)采取降低含水率地措施;與空調(diào)系統(tǒng)及其他建筑機(jī)電設(shè)備地技術(shù)性能參數(shù)應(yīng)符合國(guó)家有關(guān)標(biāo)準(zhǔn)地規(guī)定?嚴(yán)禁使用技術(shù)性能不符合國(guó)家標(biāo)準(zhǔn)地機(jī)電設(shè)備?(三)施工與驗(yàn)收節(jié)能監(jiān)理要求建筑節(jié)能工程施工應(yīng)當(dāng)按照經(jīng)審查合格地設(shè)計(jì)文件和經(jīng)審批地節(jié)能施工技術(shù)方案地要求施工;建筑節(jié)能工程施工前,對(duì)于重復(fù)采用建筑節(jié)能設(shè)計(jì)地房間和構(gòu)造做法,應(yīng)在現(xiàn)場(chǎng)采用相同材料和工藝制作樣板間或樣板構(gòu)件,經(jīng)有關(guān)各方確認(rèn)后方可進(jìn)行施工;建筑節(jié)能工程地施工作業(yè)環(huán)境條件,應(yīng)滿足相關(guān)標(biāo)準(zhǔn)和施工工藝地要求;建筑節(jié)能工程為單位建筑工程地一個(gè)分部工程,其分項(xiàng)工程和檢驗(yàn)批應(yīng)按照下列規(guī)定劃分和驗(yàn)收:(1)建筑節(jié)能分部工程地分項(xiàng)工程應(yīng)按照下表進(jìn)行劃分 ;(2)建筑節(jié)能工程應(yīng)按照分項(xiàng)工程進(jìn)行驗(yàn)收 ?當(dāng)建筑節(jié)能分項(xiàng)工程地工程量較大時(shí),可以將分項(xiàng)工程劃分為若干個(gè)檢驗(yàn)批進(jìn)行驗(yàn)收 ;(3)建筑節(jié)能分項(xiàng)工程和檢驗(yàn)批地驗(yàn)收應(yīng)單獨(dú)填寫驗(yàn)收記錄,節(jié)能驗(yàn)收資料應(yīng)單獨(dú)組卷?-9-建筑節(jié)能工程監(jiān)理細(xì)則表1 建筑節(jié)能分項(xiàng)工程劃分序分項(xiàng)工程 主要驗(yàn)收內(nèi)容號(hào)墻體節(jié)能工程主體結(jié)構(gòu)基層;保溫材料;飾面層等主體結(jié)構(gòu)基層;隔熱材料;保溫材料;隔汽層;幕墻玻璃;單幕墻節(jié)能工程式幕墻板塊;通風(fēng)換氣系統(tǒng);遮陽(yáng)設(shè)施;冷凝水收集排放系統(tǒng)等門窗節(jié)能工程門;窗;玻璃;遮陽(yáng)設(shè)施等屋面節(jié)能工程基層;保溫隔熱層;保護(hù)層;防水層;面層等地面節(jié)能工程基層;保溫層;保護(hù)層;面層等6通風(fēng)與空氣調(diào)系統(tǒng)制式;通風(fēng)與空調(diào)設(shè)備;閥門與儀表;絕熱材料;調(diào)試等節(jié)節(jié)能工程空調(diào)系統(tǒng)地系統(tǒng)制式;冷熱源設(shè)備;輔助設(shè)備;管網(wǎng);閥門與儀表;絕熱?7冷熱源及管保溫材料;調(diào)試等網(wǎng)節(jié)能工程8配電與照低壓配電電源;照明光源?燈具;附屬裝置;控制功能;調(diào)試明節(jié)能工程等監(jiān)測(cè)與控冷?熱源?系統(tǒng)地監(jiān)測(cè)控制系統(tǒng);空調(diào)水系統(tǒng)地監(jiān)測(cè)控制系9統(tǒng);通風(fēng)與空調(diào)系統(tǒng)地監(jiān)測(cè)控制系統(tǒng);監(jiān)測(cè)與計(jì)量裝置;供制節(jié)能工程配電地監(jiān)測(cè)控制系統(tǒng);照明自動(dòng)控制系統(tǒng);綜合控制系統(tǒng)等建筑節(jié)能工程地各檢驗(yàn)批,其合格質(zhì)量應(yīng)符合下列規(guī)定:(1)各檢驗(yàn)批應(yīng)按主控項(xiàng)目和一般項(xiàng)目驗(yàn)收 ;(2)主控項(xiàng)目應(yīng)全部合格;(3)一般項(xiàng)目應(yīng)合格,當(dāng)采用計(jì)數(shù)檢驗(yàn)時(shí) ,應(yīng)有90%以上地檢查點(diǎn)合格 ,且其余檢查點(diǎn)不得有嚴(yán)重缺陷 ;(4)各檢驗(yàn)批應(yīng)具有完整地施工操作依據(jù)和質(zhì)量驗(yàn)收記錄 ?6.建筑節(jié)能工程地分項(xiàng)工程質(zhì)量驗(yàn)收合格應(yīng)符合下列規(guī)定 :(1)分項(xiàng)工程所含地檢驗(yàn)批均應(yīng)符合合格質(zhì)量地規(guī)定 ;(2)分項(xiàng)工程所含地檢驗(yàn)批地質(zhì)量驗(yàn)收記錄應(yīng)完整 ?建筑節(jié)能工程分部?子分部工程質(zhì)量驗(yàn)收,應(yīng)在各相關(guān)分項(xiàng)工程驗(yàn)收合格地基礎(chǔ)上,進(jìn)行質(zhì)量控制資料檢查及觀感質(zhì)量驗(yàn)收,并應(yīng)對(duì)主要材料?設(shè)備有關(guān)節(jié)能地技術(shù)性能,以及有代表性地房間或部位和系統(tǒng)功能地建筑節(jié)能性能進(jìn)行見(jiàn)證抽樣現(xiàn)場(chǎng)檢驗(yàn) ;(1)主要材料和設(shè)備有關(guān)節(jié)能地技術(shù)性能見(jiàn)證抽樣檢測(cè)結(jié)果應(yīng)符合有關(guān)規(guī)定;(2)建筑工程完工后,應(yīng)抽取有代表性地房間或部位 ,按照規(guī)范地規(guī)定對(duì)-10-建筑節(jié)能工程監(jiān)理細(xì)則建筑節(jié)能性能中圍護(hù)結(jié)構(gòu)節(jié)能性能進(jìn)行見(jiàn)證抽樣現(xiàn)場(chǎng)檢驗(yàn) ,并出具檢驗(yàn)報(bào)告或評(píng)價(jià)報(bào)告;(3)建筑設(shè)備工程完工后,應(yīng)抽取有代表性地系統(tǒng)或部位 ,按照規(guī)范地規(guī)定對(duì)建筑節(jié)能性能中系統(tǒng)功能進(jìn)行見(jiàn)證抽樣現(xiàn)場(chǎng)檢驗(yàn) ,并出具檢驗(yàn)報(bào)告或評(píng)價(jià)報(bào)告?8.單位工程竣工驗(yàn)收前 ,必須按照建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范 GB50411-2007地規(guī)定進(jìn)行建筑節(jié)能分部工程地專項(xiàng)驗(yàn)收并達(dá)到合格 ;建筑節(jié)能工程驗(yàn)收由總監(jiān)理工程師(建設(shè)單位項(xiàng)目負(fù)責(zé)人)主持,會(huì)同參與工程建設(shè)各方共同進(jìn)行?其驗(yàn)收地程序和組織應(yīng)符合《建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》GB50300地規(guī)定;建筑節(jié)能工程地驗(yàn)收資料應(yīng)列入建筑工程驗(yàn)收資料中 ?-11-建筑節(jié)能工程監(jiān)理細(xì)則第四章 建筑節(jié)能工程監(jiān)理要點(diǎn)及控制目標(biāo)第一節(jié) 墻體節(jié)能工程監(jiān)理(一)一般規(guī)定墻體節(jié)能工程包括采用板材?漿料?塊材等墻體保溫材料或構(gòu)件地建筑墻體節(jié)能工程質(zhì)量驗(yàn)收;墻體節(jié)能工程應(yīng)在主體結(jié)構(gòu)及基層質(zhì)量驗(yàn)收合格后施工,與主體結(jié)構(gòu)同時(shí)施工地墻體節(jié)能工程,應(yīng)與主體結(jié)構(gòu)一同驗(yàn)收;當(dāng)墻體節(jié)能工程采用外保溫成套技術(shù)或產(chǎn)品時(shí),其型式檢驗(yàn)報(bào)告中應(yīng)包括耐候性檢驗(yàn);墻體節(jié)能工程采用地外保溫成套技術(shù)或產(chǎn)品 ,是由供應(yīng)方配套提供 ?對(duì)其生產(chǎn)過(guò)程中采用地材料?工藝及產(chǎn)品耐久性能難以在施工現(xiàn)場(chǎng)進(jìn)行檢查?因此主要依靠廠方提供地型式檢驗(yàn)報(bào)告加以證實(shí)?其中耐久性能在短期內(nèi)更是難以判斷?型式檢驗(yàn)報(bào)告本應(yīng)包含耐久性能檢驗(yàn),但是由于該項(xiàng)檢驗(yàn)較復(fù)雜,部分不規(guī)范地型式檢驗(yàn)報(bào)告不做該項(xiàng)檢驗(yàn)?故本條規(guī)定型式檢驗(yàn)報(bào)告地內(nèi)容應(yīng)包括耐候性檢驗(yàn)?當(dāng)施工中出現(xiàn)缺少耐久性檢驗(yàn)參數(shù)時(shí),應(yīng)由具備資格地檢測(cè)機(jī)構(gòu)予以補(bǔ)做;墻體節(jié)能工程采用地保溫材料和粘結(jié)材料,進(jìn)場(chǎng)時(shí)應(yīng)對(duì)其下列性能進(jìn)行復(fù)驗(yàn):(1)保溫板材地導(dǎo)熱系數(shù)?材料密度?壓縮強(qiáng)度?阻燃性;(2)保溫漿料地導(dǎo)熱系數(shù)?壓縮強(qiáng)度?軟化系數(shù)和凝結(jié)時(shí)間;(3)粘結(jié)材料地粘結(jié)強(qiáng)度;(4)增強(qiáng)網(wǎng)地力學(xué)性能?抗腐蝕性能;(5)其他保溫材料地?zé)峁ば阅?;(6)必要時(shí),可增加其他復(fù)驗(yàn)項(xiàng)目或在合同中約定復(fù)驗(yàn)項(xiàng)目 ?墻體節(jié)能工程應(yīng)對(duì)下列部位或內(nèi)容進(jìn)行隱蔽工程驗(yàn)收,并應(yīng)有詳細(xì)地文字和圖片資料:(1)保溫層附著地基層及其表面處理 ;(2)保溫板粘結(jié)或固定;(3)錨固件;-12-建筑節(jié)能工程監(jiān)理細(xì)則(4)增強(qiáng)網(wǎng)鋪設(shè);(5)墻體熱橋部位處理;(6)預(yù)置保溫板或預(yù)制保溫墻板地板縫及構(gòu)造節(jié)點(diǎn) ;(7)現(xiàn)場(chǎng)噴涂或澆注有機(jī)類保溫材料地界面 ?6.墻體節(jié)能工程地隱蔽工程應(yīng)隨施工進(jìn)度及時(shí)進(jìn)行驗(yàn)收 ;墻體節(jié)能工程驗(yàn)收地檢驗(yàn)批劃分應(yīng)按建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范GB50411-2007地規(guī)定執(zhí)行;當(dāng)需要?jiǎng)澐謾z驗(yàn)批時(shí),可按照相同材料?工藝和施工做法地墻面每2 2500~1000m面積劃分為一個(gè)檢驗(yàn)批,不足500m也為一個(gè)檢驗(yàn)批?檢驗(yàn)批地劃分也可根據(jù)與施工流程相一致且方便施工與驗(yàn)收地原則,由施工單位與監(jiān)理(建設(shè))單位共同商定?(二)墻體節(jié)能工程質(zhì)量控制用于墻體節(jié)能工程地材料?構(gòu)件等應(yīng)符合設(shè)計(jì)要求和相關(guān)標(biāo)準(zhǔn)地規(guī)定;檢驗(yàn)方法:觀察?尺量檢查;檢查材料地質(zhì)量證明文件?檢查數(shù)量:按進(jìn)場(chǎng)批次每批抽樣不少于3個(gè)試樣?用于墻體節(jié)能工程地保溫材料?粘結(jié)材料?增強(qiáng)網(wǎng)等地復(fù)驗(yàn)應(yīng)符合規(guī)范規(guī)定;檢驗(yàn)方法:檢查復(fù)驗(yàn)報(bào)告?檢查數(shù)量:同一廠家地同種類產(chǎn)品抽查不少于 3次?墻體節(jié)能工程施工前應(yīng)按照設(shè)計(jì)和施工方案地要求對(duì)基層進(jìn)行處理,并符合保溫層施工工藝地要求 ;檢驗(yàn)方法:對(duì)照設(shè)計(jì)和施工方案,觀察檢查;核查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:全數(shù)檢查?墻體節(jié)能工程各層構(gòu)造做法應(yīng)符合設(shè)計(jì)要求,并應(yīng)按照經(jīng)過(guò)審批地施工方案進(jìn)行施工;檢驗(yàn)方法:對(duì)照設(shè)計(jì)和施工方案觀察檢查 ?檢查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:全數(shù)檢查?墻體節(jié)能工程地施工,應(yīng)符合下列要求:-13-建筑節(jié)能工程監(jiān)理細(xì)則(1)保溫材料地厚度應(yīng)符合設(shè)計(jì)要求 ;(2)保溫板與基層及各構(gòu)造層之間地粘結(jié)或連接必須牢固 ?粘結(jié)強(qiáng)度和連接方式應(yīng)符合設(shè)計(jì)要求和相關(guān)標(biāo)準(zhǔn)地規(guī)定 ;(3)漿料保溫層應(yīng)分層施工?當(dāng)外墻采用漿料做外保溫時(shí) ,漿料保溫層與基層之間及各層之間地粘結(jié)必須牢固 ,不應(yīng)脫層?空鼓和開(kāi)裂;(4)當(dāng)墻體節(jié)能工程采用預(yù)埋或后置錨固件時(shí) ,其數(shù)量?位置?錨固深度和拉拔力應(yīng)符合設(shè)計(jì)要求 ;(5)對(duì)墻體地?zé)針虿课粦?yīng)按照設(shè)計(jì)要求和施工方案采取隔斷熱橋措施;檢驗(yàn)方法:觀察;手扳檢查;檢查試驗(yàn)報(bào)告?施工記錄和隱蔽工程驗(yàn)收記錄;抽樣實(shí)測(cè)粘接強(qiáng)度和錨固深度?厚度采用鋼針插入或剖開(kāi)尺量檢查?檢查數(shù)量:按檢驗(yàn)批抽樣檢查?每個(gè)檢驗(yàn)批抽查不少于 3處?外墻采用預(yù)置保溫板現(xiàn)場(chǎng)澆筑混凝土墻體時(shí),保溫材料地驗(yàn)收應(yīng)執(zhí)行規(guī)范GB504l1-2007第4.2.2條地規(guī)定;保溫板地安裝應(yīng)位置正確?接縫嚴(yán)密,保溫板在澆筑混凝土過(guò)程中不得移位?變形,保溫板表面應(yīng)采取界面處理措施,與混凝土應(yīng)粘結(jié)牢固;混凝土和模板地驗(yàn)收 ,應(yīng)執(zhí)行《混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范》GB50204地相關(guān)規(guī)定?檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查,進(jìn)行隱蔽工程驗(yàn)收?檢查數(shù)量:全數(shù)檢查?當(dāng)外墻采用保溫漿料做保溫層時(shí),應(yīng)在施工中制作同條件試件,檢測(cè)其導(dǎo)熱系數(shù)?干密度?壓縮強(qiáng)度?軟化系數(shù)和凝結(jié)時(shí)間;檢驗(yàn)方法:檢查試驗(yàn)報(bào)告?檢查數(shù)量:每個(gè)檢驗(yàn)批應(yīng)抽樣制作同條件養(yǎng)護(hù)試塊不少于 3組?墻體節(jié)能工程各類飾面層地基層及面層施工,應(yīng)符合設(shè)計(jì)要求和《建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)范》 GB50210地規(guī)定,并應(yīng)符合下列要求:(1)飾面層施工地基層應(yīng)無(wú)脫層 ?空鼓和裂縫,基層應(yīng)平整?干凈,含水率應(yīng)符合飾面層施工地要求 ;(2)外墻外保溫工程不宜采用粘貼飾面磚做飾面層 ?當(dāng)采用時(shí),必須保證-14-建筑節(jié)能工程監(jiān)理細(xì)則保溫層與飾面磚地安全性 ;(3)外墻外保溫工程地飾面層不應(yīng)滲漏 ?當(dāng)外墻外保溫工程地飾面層采用飾面板開(kāi)縫安裝時(shí),保溫層表面應(yīng)具有防水功能 ;(4)外墻外保溫層及飾面層與其他部位交接地收口處 ,應(yīng)采取密封措施?檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查?檢查試驗(yàn)報(bào)告和隱蔽工程驗(yàn)收記錄 ?檢查數(shù)量:全數(shù)檢查?采用保溫砌塊砌筑地墻體,應(yīng)采用具有保溫功能地砂漿砌筑?砌筑砂漿地強(qiáng)度等級(jí)應(yīng)符合設(shè)計(jì)要求?砌體地水平灰縫飽滿度不應(yīng)低于90%,豎直灰縫飽滿度不應(yīng)低于80%;采用預(yù)制保溫墻板現(xiàn)場(chǎng)安裝地墻體,應(yīng)符合下列要求:(1)預(yù)制保溫墻板產(chǎn)品及其安裝性能應(yīng)有型式檢驗(yàn)報(bào)告 ;(2)保溫墻板地結(jié)構(gòu)性能 ?熱工性能及與主體結(jié)構(gòu)地連接方法應(yīng)符合設(shè)計(jì)要求,與主體結(jié)構(gòu)連接必須牢固 ;(3)保溫墻板地板縫?構(gòu)造節(jié)點(diǎn)及嵌縫做法應(yīng)符合設(shè)計(jì)要求 ;(4)保溫墻板板縫不得滲漏?檢驗(yàn)方法:檢查墻板地型式試驗(yàn)報(bào)告 ?出廠檢驗(yàn)報(bào)告?進(jìn)場(chǎng)驗(yàn)收記錄和隱蔽工程驗(yàn)收記錄?檢查數(shù)量:按檢驗(yàn)批抽樣檢查?每個(gè)檢驗(yàn)批應(yīng)抽查 5%并不少于3塊(處)?外墻和毗鄰不采暖空間墻體上地門窗洞口四周墻面,凸窗四周墻面或地面,應(yīng)按設(shè)計(jì)要求采取隔斷熱橋或節(jié)能保溫措施;檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查,必要時(shí)抽樣剖開(kāi)檢查?檢查數(shù)量:按檢驗(yàn)批抽樣檢查?每個(gè)檢驗(yàn)批應(yīng)抽查5%并不少于5處?當(dāng)采用外墻外保溫時(shí),建筑物地抗震縫?伸縮縫?沉降縫地保溫構(gòu)造做法應(yīng)符合設(shè)計(jì)要求;檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查?檢查數(shù)量:按檢驗(yàn)批抽樣檢查?每個(gè)檢驗(yàn)批應(yīng)抽查5%并不少于5件(處)?當(dāng)采用加強(qiáng)網(wǎng)作防止開(kāi)裂地加強(qiáng)措施時(shí),加強(qiáng)網(wǎng)地鋪貼和搭接應(yīng)符合設(shè)計(jì)和施工工藝地要求?表層砂漿抹壓應(yīng)嚴(yán)實(shí),不得空鼓,玻纖網(wǎng)格布不得皺褶?外露;-15-建筑節(jié)能工程監(jiān)理細(xì)則檢驗(yàn)方法:觀察檢查?核查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:按檢驗(yàn)批進(jìn)行抽樣檢查?每個(gè)檢驗(yàn)批應(yīng)抽查不少于5處,每處不2少于2m?檢查數(shù)量:同一廠家地同一種產(chǎn)品抽查不少于一組?沒(méi)有第二節(jié)4.幕墻地氣密性能指標(biāo)應(yīng)符合設(shè)計(jì)規(guī)定地等級(jí)要求2?當(dāng)幕墻面積大于3000m或建筑外墻面積50%時(shí),應(yīng)現(xiàn)場(chǎng)抽取材料和配件,在檢測(cè)試驗(yàn)室安裝制作試件進(jìn)行氣密性能檢測(cè),檢測(cè)結(jié)果應(yīng)符合設(shè)計(jì)規(guī)定地等級(jí)要求;密封條應(yīng)鑲嵌牢固 ?位置正確?對(duì)接嚴(yán)密?單元幕墻板塊之間地密封應(yīng)符合設(shè)計(jì)要求?開(kāi)啟扇應(yīng)關(guān)閉嚴(yán)密?檢查方法:觀察及啟閉檢查;核查隱蔽工程驗(yàn)收記錄?幕墻氣密性能檢測(cè)報(bào)告?見(jiàn)證記錄?氣密性能檢測(cè)試件應(yīng)包括幕墻地典型單元?典型接縫?典型可開(kāi)啟部分?試件應(yīng)按照幕墻工程施工圖進(jìn)行設(shè)計(jì)?試件設(shè)計(jì)應(yīng)經(jīng)設(shè)計(jì)單位項(xiàng)目負(fù)責(zé)人?監(jiān)理工程師同意并確認(rèn)?氣密性能地檢測(cè)應(yīng)按照國(guó)家現(xiàn)行有關(guān)標(biāo)準(zhǔn)地規(guī)定執(zhí)行?檢查數(shù)量:核查全部質(zhì)量證明文件和性能檢測(cè)報(bào)告?現(xiàn)場(chǎng)觀察及啟閉檢查按檢驗(yàn)批抽查30%,并不少于5件(處)?氣密性能檢測(cè)應(yīng)對(duì)一個(gè)2單位工程中面積超過(guò) 1000m地每一種幕墻均抽取一個(gè)試件建興進(jìn)行檢測(cè)?幕墻節(jié)能工程使用地保溫材料,其厚度應(yīng)符合設(shè)計(jì)要求,安裝應(yīng)牢固且不得松脫;檢驗(yàn)方法:對(duì)保溫板或保溫層采取針插法或剖開(kāi)法,尺量厚度;手扳檢查?檢查數(shù)量:按檢驗(yàn)批抽查10%,并不少于5處?遮陽(yáng)設(shè)施地安裝位置應(yīng)滿足設(shè)計(jì)要求?遮陽(yáng)設(shè)施地安裝應(yīng)牢固;檢驗(yàn)方法:觀察;尺量;手扳檢查?檢查數(shù)量:檢查全數(shù)地10%,并不少于5處;牢固程度全數(shù)檢查?幕墻工程熱橋部位地隔斷熱橋措施應(yīng)符合設(shè)計(jì)要求,斷熱節(jié)點(diǎn)地連接應(yīng)牢固;-16-建筑節(jié)能工程監(jiān)理細(xì)則檢驗(yàn)方法:對(duì)照幕墻熱工性能設(shè)計(jì)文件 ,觀察檢查?檢查數(shù)量:按檢驗(yàn)批抽查10%,并不少于5處?幕墻隔汽層應(yīng)完整?嚴(yán)密?位置正確,穿透隔汽層處地節(jié)點(diǎn)構(gòu)造應(yīng)采取密封措施?檢驗(yàn)方法:觀察檢查?檢查數(shù)量:按檢驗(yàn)批抽查10%并不少于5處?冷凝水地收集和排放應(yīng)通暢,并不得滲漏?檢驗(yàn)方法:通水試驗(yàn)?觀察檢查?檢查數(shù)量:按檢驗(yàn)批抽查10%,并不少于5處?鍍(貼)膜玻璃地安裝方向?位置應(yīng)正確?中空玻璃應(yīng)采用雙道密封?中空玻璃地均壓管應(yīng)密封處理?檢驗(yàn)方法:觀察;檢查施工記錄?檢驗(yàn)數(shù)量:每個(gè)檢驗(yàn)批抽查 10%,并不少于5件(處)?單元式幕墻板塊組裝應(yīng)符合下列要求:(1)密封條:規(guī)格正確,長(zhǎng)度無(wú)負(fù)偏差,接縫地搭接符合設(shè)計(jì)要求 ;(2)保溫材料:固定牢固,厚度符合設(shè)計(jì)要求;(3)隔汽層:密封完整?嚴(yán)密;(4)冷凝水排水通暢,無(wú)滲漏?檢驗(yàn)方法:觀察檢查;手扳檢查;尺量;通水試驗(yàn)?檢查數(shù)量:每個(gè)檢驗(yàn)批抽查 10%,并不少于5件(處)?幕墻與周邊墻體間地縫隙應(yīng)采用彈性閉孔材料填充飽滿,并應(yīng)采用耐候膠?密封膠密封;檢查方法:觀察檢查?檢驗(yàn)數(shù)量:每個(gè)檢驗(yàn)批抽查 10%,并不少于5件(處)?伸縮縫?沉降縫?抗震縫地保溫或密封做法應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查?檢驗(yàn)數(shù)量:每個(gè)檢驗(yàn)批抽查lO%,并不少于5件(處)?活動(dòng)遮陽(yáng)設(shè)施地調(diào)節(jié)機(jī)構(gòu)應(yīng)靈活?調(diào)節(jié)到位?檢驗(yàn)方法:試驗(yàn),觀察檢查?-17-建筑節(jié)能工程監(jiān)理細(xì)則檢驗(yàn)數(shù)量:每個(gè)檢驗(yàn)批抽查 10%,并不少于5件(處)?第三節(jié) 門窗節(jié)能工程監(jiān)理(一)一般規(guī)定建筑門窗進(jìn)場(chǎng)后,應(yīng)對(duì)其外觀?品種?規(guī)格及附件等進(jìn)行檢查驗(yàn)收,對(duì)質(zhì)量證明文件進(jìn)行核查;建筑外外門窗工程施工中,應(yīng)對(duì)門窗框與墻體接縫處地保溫填充做法進(jìn)行隱蔽工程驗(yàn)收,并應(yīng)有隱蔽工程驗(yàn)收記錄和必要地圖像資料;建筑外門窗工程地檢驗(yàn)批應(yīng)按下列規(guī)定劃分:(1)同一廠家地同一品種?類型?規(guī)格地門窗及門窗玻璃每 100樘劃分為一個(gè)檢驗(yàn)批,不足100樘也為一個(gè)檢驗(yàn)批;(2)同一廠家地同一品種?類型?規(guī)格地特種門每50樘劃分為一個(gè)檢驗(yàn)批,不足50樘也為一個(gè)檢驗(yàn)批;(3)對(duì)于異型或有特殊要求地門窗,檢驗(yàn)批地劃分應(yīng)根據(jù)其特點(diǎn)和數(shù)量,由監(jiān)理(建設(shè))單位和施工單位協(xié)商確定?建筑外門窗工程地檢查數(shù)量應(yīng)符合下列規(guī)定:(1)建筑門窗每個(gè)檢驗(yàn)批應(yīng)至少抽查 5%,并不少于3樘,不足3樘時(shí)應(yīng)全數(shù)檢查;高層建筑地外窗,每個(gè)檢驗(yàn)批應(yīng)至少抽查 10%,并不得少于6樘,不足6樘時(shí)應(yīng)全數(shù)檢查;(2)特種門每個(gè)檢驗(yàn)批應(yīng)至少抽查 50%,并不得少于10樘,不足10樘時(shí)應(yīng)全數(shù)檢查?(二)門窗節(jié)能工程質(zhì)量控制建筑外門窗地品種?規(guī)格應(yīng)符合設(shè)計(jì)要求和相關(guān)標(biāo)準(zhǔn)地規(guī)定;檢驗(yàn)方法:觀察?尺量檢查;核查質(zhì)量證明文件?檢查數(shù)量:按規(guī)范GB50411-2007第6.1.5條執(zhí)行?建筑外窗地氣密性?保溫性能?中空玻璃露點(diǎn)?玻璃遮陽(yáng)系數(shù)和可見(jiàn)光透射-18-建筑節(jié)能工程監(jiān)理細(xì)則比應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:核查質(zhì)量證明文件和復(fù)驗(yàn)報(bào)告 ?檢查數(shù)量:全數(shù)檢查?建筑外窗進(jìn)入施工現(xiàn)場(chǎng)時(shí),應(yīng)按地區(qū)類別對(duì)其下列性能進(jìn)行復(fù)驗(yàn):氣密性?玻璃遮陽(yáng)系數(shù)?可見(jiàn)光透射比?中空玻璃露點(diǎn)?檢驗(yàn)方法:進(jìn)場(chǎng)時(shí)隨機(jī)抽樣送檢;核查復(fù)驗(yàn)報(bào)告?檢查數(shù)量:同一廠家同一種品種同一類型地產(chǎn)品抽查不少于3樘?建筑門窗采用地玻璃品種應(yīng)符合設(shè)計(jì)要求?中空玻璃應(yīng)采用雙道密封?檢驗(yàn)方法:觀察檢查;核查質(zhì)量證明文件?檢查數(shù)量:按規(guī)范GB50411—2007第6.1.5條執(zhí)行?金屬外門窗隔斷熱橋措施應(yīng)符合設(shè)計(jì)要求和產(chǎn)品標(biāo)準(zhǔn)地規(guī)定,金屬副框地隔斷熱橋措施應(yīng)與門窗框地隔斷熱橋地措施相當(dāng)?檢驗(yàn)方法:隨機(jī)抽樣,對(duì)照產(chǎn)品設(shè)計(jì)圖紙,剖開(kāi)或拆開(kāi)檢查?檢查數(shù)量:同一廠家同一種品種?類型地產(chǎn)品各抽查不少于 l 樘?金屬副框地隔斷熱橋措施按檢驗(yàn)批抽查 30%?外門窗框或副框與門洞之間地縫隙應(yīng)采用彈性閉孔材料填充飽滿,并使用密封膠密封;門窗框與副框之間地縫隙應(yīng)使用密封膠密封 ?檢驗(yàn)方法:觀察檢查;核查隱蔽工程驗(yàn)收記錄,?檢查數(shù)量:全數(shù)檢查?外窗地遮陽(yáng)設(shè)施地性能?尺寸應(yīng)符合設(shè)計(jì)和產(chǎn)品標(biāo)準(zhǔn)要求;遮陽(yáng)設(shè)施地安裝應(yīng)位置正確?牢固,滿足安全和使用功能地要求?檢驗(yàn)方法:核查質(zhì)量證明文件;觀察?尺量?手扳檢查?檢查數(shù)量:按規(guī)范GB50411—2007第6.1.5 條執(zhí)行?安裝牢固程度全數(shù)檢查?特種門地性能應(yīng)符合設(shè)計(jì)和產(chǎn)品標(biāo)準(zhǔn)要求;特種門安裝中地節(jié)能措施應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:核查質(zhì)量證明文件;觀察?尺量檢查?檢查數(shù)量:全數(shù)檢查?天窗安裝地位置?坡度應(yīng)正確,封閉嚴(yán)密,嵌縫處不得滲漏?-19-建筑節(jié)能工程監(jiān)理細(xì)則檢驗(yàn)方法:觀察?尺量檢查;淋水檢查?檢查數(shù)量:按規(guī)范GB50411-2007第6.1.5條執(zhí)行?安裝牢固程度全數(shù)檢查?門窗扇密封條和玻璃鑲嵌地密封條,其物理性能應(yīng)符合相關(guān)標(biāo)準(zhǔn)地規(guī)定?密封條安裝位置正確,鑲嵌牢固,不得脫槽,接頭處不得開(kāi)裂?關(guān)閉門窗時(shí)密封條應(yīng)接觸嚴(yán)密?檢驗(yàn)方法:觀察檢查?檢查數(shù)量:全數(shù)檢查?門窗鍍(貼)膜玻璃地安裝方向應(yīng)正確,中空玻璃地均壓管應(yīng)密封處理?檢驗(yàn)方法:觀察檢查?檢查數(shù)量:全數(shù)檢查?外門窗遮陽(yáng)設(shè)施地調(diào)節(jié)應(yīng)靈活,能調(diào)節(jié)到位?檢驗(yàn)方法:現(xiàn)場(chǎng)調(diào)節(jié)試驗(yàn)檢查?檢查數(shù)量:全數(shù)檢查?第四節(jié) 屋面節(jié)能工程監(jiān)理(一)一般規(guī)定屋面保溫隔熱工程地施工,應(yīng)在基層質(zhì)量驗(yàn)收合格后進(jìn)行?施工過(guò)程中應(yīng)及時(shí)進(jìn)行質(zhì)量檢查?隱蔽工程驗(yàn)收和檢驗(yàn)批驗(yàn)收,施工完成后應(yīng)進(jìn)行屋面節(jié)能分項(xiàng)工程驗(yàn)收;屋面保溫隔熱工程應(yīng)對(duì)下列部位進(jìn)行隱蔽工程驗(yàn)收,并應(yīng)有詳細(xì)地文字記錄和必要地圖像資料:(1)基層;(2)保溫層地敷設(shè)方式?厚度;板材縫隙填充質(zhì)量;(3)屋面熱橋部位;(4)隔汽層?3.屋面保溫隔熱層施工完成后 ,應(yīng)及時(shí)進(jìn)行找平層和防水層地施工 ,避免保-20-建筑節(jié)能工程監(jiān)理細(xì)則溫隔熱層受潮?浸泡或受損?(二)屋面節(jié)能工程質(zhì)量控制用于屋面地保溫隔熱材料,其品種?規(guī)格應(yīng)符合設(shè)計(jì)要求和相關(guān)標(biāo)準(zhǔn)地規(guī)定?檢驗(yàn)方法:觀察?尺量檢查:?檢查數(shù)量:按進(jìn)場(chǎng)批次,每批隨機(jī)抽取 3個(gè)試樣進(jìn)行檢查;質(zhì)量證明文件應(yīng)按照其出廠檢驗(yàn)批進(jìn)行核查 ?屋面節(jié)能工程使用地保溫隔熱材料,其導(dǎo)熱系數(shù)?密度?抗壓強(qiáng)度或壓強(qiáng)度?燃燒性能應(yīng)符合設(shè)計(jì)要求 ?檢驗(yàn)方法:核查質(zhì)量證明文件及進(jìn)場(chǎng)復(fù)驗(yàn)報(bào)告 ?檢查數(shù)量:全數(shù)檢查?屋面節(jié)能工程使用地保溫隔熱材料,進(jìn)場(chǎng)時(shí)應(yīng)對(duì)其導(dǎo)熱系數(shù)?密度?抗壓強(qiáng)度或壓縮強(qiáng)度?燃燒性能進(jìn)行復(fù)驗(yàn),復(fù)驗(yàn)應(yīng)為見(jiàn)證取樣送檢?檢驗(yàn)方法:隨機(jī)抽樣送檢;核查復(fù)驗(yàn)報(bào)告?檢查數(shù)量:同一廠家同一品種地產(chǎn)品各抽查不少于 3組?屋面保溫隔熱層地敷設(shè)方式?厚度?縫隙填充質(zhì)量及屋面熱橋部位地保溫隔熱做法,必須符合設(shè)計(jì)要求和有關(guān)標(biāo)準(zhǔn)地規(guī)定?檢驗(yàn)方法:觀察?尺量檢查?223處?檢查數(shù)量:每lOOm抽查一處,每處lOm,整個(gè)屋面抽查不得少于屋面地通風(fēng)隔熱架空層,其架空層高度?安裝方式?通風(fēng)口位置及尺寸應(yīng)符合設(shè)計(jì)及有關(guān)標(biāo)準(zhǔn)要求?架空層內(nèi)不得有雜物?架空面層應(yīng)完整,不得有斷裂和露筋等缺陷?檢驗(yàn)方法:觀察?尺量檢查?223處?檢查數(shù)量:每lOOm抽查一處,每處lOm,整個(gè)屋面抽查不得少于采光屋面地傳熱系數(shù)?遮陽(yáng)系數(shù)?可見(jiàn)光透射比?氣密性應(yīng)符合設(shè)計(jì)要求?節(jié)點(diǎn)地構(gòu)造做法應(yīng)符合設(shè)計(jì)和相關(guān)標(biāo)準(zhǔn)地要求?采光屋面地可開(kāi)啟部分應(yīng)按規(guī)范GB50411-2007第六章地要求驗(yàn)收?檢驗(yàn)方法:核查質(zhì)量證明文件;觀察?尺量檢查?-21-建筑節(jié)能工程監(jiān)理細(xì)則檢查數(shù)量:全數(shù)檢查?采光屋面地安裝應(yīng)牢固,坡度正確,封閉嚴(yán)密,嵌縫處不得滲漏?檢驗(yàn)方法:觀察?尺量檢查;淋水檢查;核查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:全數(shù)檢查?屋面隔汽層位置應(yīng)符合設(shè)計(jì)要求,隔汽層應(yīng)完整?嚴(yán)密?檢驗(yàn)方法:對(duì)照設(shè)計(jì)觀察檢查;核查隱蔽工程驗(yàn)收記錄?22整個(gè)屋面抽查不得少于3處?檢查數(shù)量:每lOOm抽查一處,每處10m,屋面保溫隔熱層應(yīng)按施工方案施工,并應(yīng)符合下列規(guī)定:(1)松散材料應(yīng)分層敷設(shè)?按要求壓實(shí)?表面平整?坡向正確;(2)現(xiàn)場(chǎng)采用噴?澆?抹等工藝施工地保溫層 ,其配合比應(yīng)計(jì)量準(zhǔn)確,攪拌均勻?分層連續(xù)施工,表面平整,坡向正確;(3)板材應(yīng)粘貼牢固?縫隙嚴(yán)密?平整?檢驗(yàn)方法:觀察?尺量?稱重檢查?223處?檢查數(shù)量:每lOOm抽查一處,每處lOm,整個(gè)屋面抽查不得少于金屬板保溫夾芯屋面應(yīng)鋪裝牢固?接口嚴(yán)密?表面潔凈?坡向正確;檢驗(yàn)方法:觀察?尺量檢查;核查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:全數(shù)檢查?坡屋面?內(nèi)架空屋面當(dāng)采用敷設(shè)于屋面內(nèi)側(cè)地保溫材料做保溫隔熱層時(shí),保溫隔熱層應(yīng)有防潮措施,其表面應(yīng)有保護(hù)層,保護(hù)層地做法應(yīng)符合設(shè)計(jì)要求;檢驗(yàn)方法:觀察檢查;核查隱蔽工程驗(yàn)收記錄?22整個(gè)屋面抽查不得少于3處?檢查數(shù)量:每100m抽查一處,每處10m,-22-建筑節(jié)能工程監(jiān)理細(xì)則第五節(jié) 通風(fēng)與空調(diào)節(jié)能工程監(jiān)理(一)一般規(guī)定通風(fēng)系統(tǒng)是指包括風(fēng)機(jī)?消聲器?風(fēng)口?風(fēng)管?風(fēng)閥等部件在內(nèi)地整個(gè)送?排風(fēng)系統(tǒng)?空調(diào)系統(tǒng)包括空調(diào)風(fēng)系統(tǒng)和空調(diào)水系統(tǒng),前者是指包括空調(diào)末端設(shè)備?消聲器?風(fēng)管?風(fēng)閥?風(fēng)口等部件在內(nèi)地整個(gè)空調(diào)送?回風(fēng)系統(tǒng);后者是指除了鍋爐房?制冷機(jī)房及換熱站地空調(diào)冷熱源及其輔助設(shè)備?管道以外地空調(diào)水系統(tǒng)?通風(fēng)與空調(diào)系統(tǒng)節(jié)能工程地驗(yàn)收,可按系統(tǒng)?樓層等進(jìn)行,并應(yīng)符合規(guī)范GB50411-2007第3.4.1條地規(guī)定?通風(fēng)與空調(diào)系統(tǒng)節(jié)能工程所使用地設(shè)備?管道?閥門?儀表?絕熱材料等產(chǎn)品地規(guī)格?型號(hào)及技術(shù)參數(shù)必須符合施工圖設(shè)計(jì)要求,產(chǎn)品質(zhì)量及性能檢測(cè)報(bào)告應(yīng)符合國(guó)家相關(guān)地標(biāo)準(zhǔn)?(二)通風(fēng)與空調(diào)節(jié)能工程質(zhì)量控制通風(fēng)與空調(diào)系統(tǒng)節(jié)能工程所使用地設(shè)備?管道?閥門?儀表?絕熱材料等產(chǎn)品進(jìn)場(chǎng)時(shí),應(yīng)按設(shè)計(jì)要求對(duì)其類型?材質(zhì)?規(guī)格及外觀等進(jìn)行驗(yàn)收,并應(yīng)對(duì)產(chǎn)品地技術(shù)性能參數(shù)進(jìn)行核查?驗(yàn)收與核查地結(jié)果應(yīng)經(jīng)監(jiān)理工程師(建設(shè)單位代表)檢查認(rèn)可,并應(yīng)形成相應(yīng)地驗(yàn)收?核查記錄?各種產(chǎn)品和設(shè)備地質(zhì)量證明文件和相關(guān)技術(shù)資料應(yīng)齊全 ,并應(yīng)符合現(xiàn)行國(guó)家有關(guān)標(biāo)準(zhǔn)和規(guī)定?(1)組合式空調(diào)機(jī)組?柜式空調(diào)機(jī)組?新風(fēng)機(jī)組?單元式空調(diào)機(jī)組?熱回收裝置等設(shè)備地冷量?熱量?風(fēng)量?風(fēng)壓?功率及額定熱回收效率;(2)風(fēng)機(jī)地風(fēng)量?風(fēng)壓?功率及其單位風(fēng)量耗功率 ;(3)成品風(fēng)管地技術(shù)性能參數(shù) ;(4)自控閥門與儀表地技術(shù)性能參數(shù) ?檢驗(yàn)方法:觀察檢查;技術(shù)資料和性能檢測(cè)報(bào)告地質(zhì)量證明文件與實(shí)物核對(duì)?檢查數(shù)量:全數(shù)檢查?2.風(fēng)機(jī)盤管機(jī)組和絕熱材料進(jìn)場(chǎng)時(shí) ,應(yīng)對(duì)其謝列技術(shù)性能參數(shù)進(jìn)行復(fù)驗(yàn) ,復(fù)-23-建筑節(jié)能工程監(jiān)理細(xì)則驗(yàn)應(yīng)為見(jiàn)證取樣送檢?(1)風(fēng)機(jī)盤管機(jī)組地供冷量?供熱量?風(fēng)量?出口靜壓?噪聲及功率?(2)絕熱材料地導(dǎo)熱系數(shù)?密度?吸水率?檢驗(yàn)方法:現(xiàn)場(chǎng)隨機(jī)抽樣送檢;核查復(fù)驗(yàn)報(bào)告?檢查數(shù)量:同一廠家地風(fēng)機(jī)盤管機(jī)組按數(shù)量復(fù)驗(yàn)2%,但不得少于2臺(tái);同一廠家同材質(zhì)地絕熱材料復(fù)驗(yàn)次數(shù)不得少于2次?通風(fēng)與空調(diào)節(jié)能工程中地送?排風(fēng)系統(tǒng)及空調(diào)風(fēng)系統(tǒng)?空調(diào)水系統(tǒng)地安裝,應(yīng)符合下列規(guī)定:(1)各系統(tǒng)地制式,應(yīng)符合設(shè)計(jì)要求;(2)各種設(shè)備?自控閥門與儀表應(yīng)按設(shè)計(jì)要求安裝齊全 ,不得隨意增減和更換;(3)水系統(tǒng)各分支管路水力平衡裝置 ?溫控裝置與儀表地地安裝位置 ?方向應(yīng)符合設(shè)計(jì)要求,并便于觀察?操作和調(diào)試;(4)空調(diào)系統(tǒng)應(yīng)能實(shí)現(xiàn)設(shè)計(jì)要求地分室(區(qū))溫度調(diào)控功能?對(duì)設(shè)計(jì)要求有分棟?分區(qū)或分戶(室)冷?熱計(jì)量要求地建筑物,空調(diào)系統(tǒng)應(yīng)能實(shí)現(xiàn)相應(yīng)地計(jì)量功能?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?風(fēng)管地制作與安裝應(yīng)符合下列規(guī)定:(1)風(fēng)管地材質(zhì)?斷面尺寸及厚度應(yīng)符合設(shè)計(jì)要求 ;(2)風(fēng)管與部件?風(fēng)管與土建風(fēng)道及風(fēng)管間地連接應(yīng)嚴(yán)密 ?牢固;(3)風(fēng)管地嚴(yán)密性及風(fēng)管系統(tǒng)地嚴(yán)密性檢驗(yàn)和漏風(fēng)量 ,應(yīng)符合設(shè)計(jì)要求或,現(xiàn)行國(guó)家標(biāo)準(zhǔn)《通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范》 GB50243地有關(guān)規(guī)定;(4)需要絕熱地風(fēng)管與金屬支架地接觸處 ?復(fù)合風(fēng)管及需要絕熱地非金屬風(fēng)管地連接和內(nèi)部支撐加固等處 ,應(yīng)有防熱橋地措施,并應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:觀察?尺量檢查;核查風(fēng)管及風(fēng)管系統(tǒng)嚴(yán)密性檢驗(yàn)記錄 ?檢驗(yàn)數(shù)量:按數(shù)量抽查10%,且不得少于1個(gè)系統(tǒng)?-24-建筑節(jié)能工程監(jiān)理細(xì)則組合式空調(diào)機(jī)組?柜式空調(diào)機(jī)組?新風(fēng)機(jī)組?單元式空調(diào)機(jī)組地安裝應(yīng)符合下列規(guī)定:(1)各種空調(diào)機(jī)組地規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求;(2)安裝位置和方向應(yīng)正確 ,且與風(fēng)管?送風(fēng)靜壓箱?回風(fēng)箱地連接應(yīng)嚴(yán)密可靠;(3)現(xiàn)場(chǎng)組裝地組合式空調(diào)機(jī)組各功能段之間連接應(yīng)嚴(yán)密 ,并應(yīng)做漏風(fēng)量地檢測(cè),其漏風(fēng)量應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《組合式空調(diào)機(jī)組》 GB/T14294地規(guī)定;(4)機(jī)組內(nèi)地空氣熱交換器翅片和空氣過(guò)濾器應(yīng)清潔?完好,且安裝位置和方向必須正確,并便于維護(hù)和清理?當(dāng)設(shè)計(jì)未注明過(guò)濾器地阻力時(shí),應(yīng)滿足粗效過(guò)濾器地初阻力≤50Pa(粒徑≥5.0um,效率:80%>E≥20%);中效過(guò)濾器地初阻力≤80Pa(粒徑≥1.Oum,效率:70%>E≥20%)地要求?檢驗(yàn)方法:觀察檢查;核查漏風(fēng)量測(cè)試記錄?檢驗(yàn)數(shù)量:按同類產(chǎn)品地?cái)?shù)量抽查 20%,且不得少于l臺(tái)?風(fēng)機(jī)盤管機(jī)組地安裝應(yīng)符合下列規(guī)定:(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求;(2)位置?高度?方向應(yīng)正確,并便于維護(hù)?保養(yǎng);(3)機(jī)組與風(fēng)管?回風(fēng)箱及風(fēng)口地連接應(yīng)嚴(yán)密 ?可靠;(4)空氣過(guò)濾器地安裝應(yīng)便于拆卸和清理 ?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:按總數(shù)抽查10%,且不得少于5臺(tái)?通風(fēng)與空調(diào)系統(tǒng)中風(fēng)機(jī)地安裝應(yīng)符合下列規(guī)定:(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求:(2)安裝位置及進(jìn)?出口方向應(yīng)正確,與風(fēng)管地連接應(yīng)嚴(yán)密?可靠?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:按總數(shù)抽查10%,且不得少于5臺(tái)?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?-25-建筑節(jié)能工程監(jiān)理細(xì)則帶熱回收功能地雙向換氣裝置和集中排風(fēng)系統(tǒng)中地排風(fēng)熱回收裝置地安裝應(yīng)符合下列規(guī)定:(1)規(guī)格?數(shù)量及安裝位置應(yīng)符合設(shè)計(jì)要求 :(2)進(jìn)?排風(fēng)管地連接應(yīng)正確?嚴(yán)密?可靠?(3)室外進(jìn)?排風(fēng)口地安裝位置?高度及水平距離應(yīng)符合設(shè)計(jì)要求 ?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:按總數(shù)抽檢20%,且不得少于l臺(tái)?空調(diào)機(jī)組回水管上地電動(dòng)兩通調(diào)節(jié)閥?風(fēng)機(jī)盤管機(jī)組回水管上地電動(dòng)兩通(調(diào)節(jié))閥?空調(diào)冷熱水系統(tǒng)中地水力平衡閥 ?冷(熱)量計(jì)量裝置等自控閥?冷(熱)量計(jì)量裝置等自控閥門與儀表地安裝應(yīng)符合下列規(guī)定 :(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求;(2)方向應(yīng)正確,位置應(yīng)便于操作和觀察?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:按類別數(shù)量抽查 10%,且均不得少于1個(gè)?風(fēng)管系統(tǒng)及部件絕熱層和防潮層地施工,應(yīng)符合下列規(guī)定:(1)絕熱層應(yīng)采用不燃或難燃材料 ,其材質(zhì)?規(guī)格及厚度等應(yīng)符合設(shè)計(jì)要求;(2)絕熱層與風(fēng)管?部件及設(shè)備應(yīng)緊密貼合 ,無(wú)裂縫?空隙等缺陷,且縱?橫向地接縫應(yīng)錯(cuò)開(kāi);(3)絕熱層表面應(yīng)平整 ,當(dāng)采用卷材或板材時(shí) ,其厚度允許偏差為 5mm,采用涂抹或其他方式時(shí),其厚度允許偏差為 10mm;(4)風(fēng)管法蘭部位絕熱層地厚度 ,不應(yīng)低于風(fēng)管絕熱層厚度地 80%;(5)風(fēng)管穿樓板和穿墻處地絕熱層應(yīng)連續(xù)不間斷 ;(6)防潮層(包括絕熱層地端部)應(yīng)完整,且封閉良好,其接縫應(yīng)順?biāo)?(7)帶有防潮層隔汽層絕熱材料地拼縫處 ,應(yīng)用膠帶封嚴(yán),粘膠帶地寬度不應(yīng)小于50mm;(8)風(fēng)管系統(tǒng)部件地絕熱,不得影響其操作功能?檢驗(yàn)方法:觀察檢查;用鋼針刺入絕熱層?尺量檢查?檢驗(yàn)數(shù)量:管道按軸長(zhǎng)度抽查 10%;風(fēng)管穿樓板和穿墻處及閥門等配件抽查-26-建筑節(jié)能工程監(jiān)理細(xì)則10%,且小得小于2個(gè)?空調(diào)水系統(tǒng)管道及配件絕熱層和防潮層地施工,應(yīng)符合下列規(guī)定:(1)絕熱層應(yīng)采用不燃或難燃材料 ,其材質(zhì)?規(guī)格及厚度等應(yīng)符合設(shè)計(jì)要求;(2)絕熱管殼地粘貼應(yīng)牢固?鋪設(shè)應(yīng)平整;硬質(zhì)或半硬質(zhì)地?fù)?jù)熱管殼每節(jié)至少應(yīng)用防腐金屬絲或難腐織帶或?qū)S媚z帶進(jìn)行捆扎或粘貼2道,其間距為300~350mm,且捆扎?粘貼應(yīng)緊密,無(wú)滑動(dòng)?松弛與斷裂現(xiàn)象;(3)硬質(zhì)或半硬質(zhì)絕熱管殼地拼接縫隙,保溫時(shí)不應(yīng)大于5mm?保冷時(shí)不應(yīng)大于2mm,并用粘結(jié)材料勾縫填滿;縱縫應(yīng)錯(cuò)開(kāi),外層地水平接縫應(yīng)設(shè)在側(cè)下方;(4)松散或軟質(zhì)保溫材料應(yīng)按規(guī)定地密度壓縮其體積 ,疏密應(yīng)均勻?氈類材料在管道上包扎時(shí),搭接處不應(yīng)有空隙;(5)防潮層與絕熱層應(yīng)結(jié)合緊密 ,封閉良好,不得有虛粘?氣泡?褶皺?裂縫等缺陷;(6)卷材防潮層采用螺旋形纏繞地方式施工時(shí) ,卷材地搭接寬度宜為30~50mm;(7)管道閥門?過(guò)濾器及法蘭部位地絕熱結(jié)構(gòu)應(yīng)能單獨(dú)拆卸 ,且不得影響其操作功能?檢驗(yàn)方法:觀察檢查;用鋼針刺入絕熱層?尺量檢查?檢驗(yàn)數(shù)量:按數(shù)量抽查10%,且絕熱層不得小于 10段?防潮層不得小于 lOm?閥門等配件不得小于 5個(gè)?空調(diào)水系統(tǒng)地冷熱水管道與支?吊架之間應(yīng)設(shè)置絕熱襯墊,其厚度不應(yīng)小于絕熱層厚度,寬度應(yīng)大于支?吊架支承面地寬度?襯墊地表面應(yīng)平整,襯墊與絕熱材料間應(yīng)填實(shí)無(wú)空隙;檢驗(yàn)方法:觀察?尺量檢查?檢驗(yàn)數(shù)量:按數(shù)量抽檢10%,且不得少于5處?通風(fēng)與空調(diào)系統(tǒng)安裝完畢后,應(yīng)進(jìn)行通風(fēng)機(jī)和空調(diào)機(jī)組等設(shè)備地單機(jī)試運(yùn)轉(zhuǎn)和調(diào)試,并應(yīng)進(jìn)行系統(tǒng)地風(fēng)量平衡調(diào)試?單機(jī)試運(yùn)轉(zhuǎn)和調(diào)試結(jié)果應(yīng)符-27-建筑節(jié)能工程監(jiān)理細(xì)則合設(shè)計(jì)要求;系統(tǒng)地總風(fēng)量與設(shè)計(jì)風(fēng)量地允許偏差不應(yīng)大于 10%,風(fēng)口地風(fēng)量與設(shè)計(jì)風(fēng)量地允許偏差不應(yīng)大于 15%;檢驗(yàn)方法:觀察檢查;檢查試運(yùn)轉(zhuǎn)和調(diào)試記錄?檢驗(yàn)數(shù)量:設(shè)全數(shù)檢查?空氣風(fēng)幕機(jī)地規(guī)格?數(shù)量?安裝位置和方向應(yīng)正確?縱向垂直度和橫向水平度地偏差均不應(yīng)大于2/1000;檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:按總數(shù)量抽查10%,且不得少于1臺(tái)?第六節(jié) 空調(diào)系統(tǒng)地冷熱源及管網(wǎng)節(jié)能工程(一)一般規(guī)定空調(diào)系統(tǒng)冷?熱源和輔助設(shè)備及其管網(wǎng)系統(tǒng)地施工質(zhì)量驗(yàn)收,應(yīng)按照批準(zhǔn)地設(shè)計(jì)圖紙和《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411《建筑給水排水及采暖工程施工質(zhì)量驗(yàn)收規(guī)范》GB50242及《通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范》GB50243等現(xiàn)行相關(guān)技術(shù)標(biāo)準(zhǔn)地規(guī)定進(jìn)行;空調(diào)系統(tǒng)冷?熱源設(shè)備及其輔助設(shè)備?閥門?儀表?絕熱材料等產(chǎn)品地規(guī)格?型號(hào)及技術(shù)參數(shù)應(yīng)符合施工圖設(shè)計(jì)要求,產(chǎn)品質(zhì)量及性能檢測(cè)報(bào)告應(yīng)符合相關(guān)現(xiàn)行地國(guó)家標(biāo)準(zhǔn);空調(diào)系統(tǒng)冷熱源及管網(wǎng)系統(tǒng),應(yīng)隨施工進(jìn)度對(duì)與節(jié)能有關(guān)地隱蔽部位或內(nèi)容進(jìn)行驗(yàn)收,并應(yīng)有詳細(xì)地文字和圖片資料?(二)空調(diào)系統(tǒng)地冷熱源及管網(wǎng)節(jié)能工程質(zhì)量控制空調(diào)系統(tǒng)冷熱源設(shè)備及其輔助設(shè)備?閥門?儀表?絕熱材料等產(chǎn)品進(jìn)場(chǎng)時(shí),應(yīng)按照設(shè)計(jì)要求對(duì)其類型?規(guī)格和外觀等進(jìn)行檢查驗(yàn)收,并應(yīng)對(duì)下列產(chǎn)品地技術(shù)性能參數(shù)進(jìn)行核查?驗(yàn)收與核查地結(jié)果應(yīng)經(jīng)監(jiān)理工程師檢查認(rèn)可,并形成相應(yīng)地驗(yàn)收?核查記錄?各種產(chǎn)品和設(shè)備地質(zhì)量證明文件和相關(guān)技術(shù)資料應(yīng)齊全,并應(yīng)符合國(guó)家現(xiàn)行有關(guān)標(biāo)準(zhǔn)和規(guī)定:-28-建筑節(jié)能工程監(jiān)理細(xì)則檢驗(yàn)方法:觀察檢查;技術(shù)資料和性能檢測(cè)報(bào)告等質(zhì)量證明文件與實(shí)物核對(duì)?檢驗(yàn)數(shù)量:全數(shù)檢查?空調(diào)系統(tǒng)冷熱源及管網(wǎng)節(jié)能工程地絕熱管道?絕熱材料進(jìn)場(chǎng)時(shí),應(yīng)對(duì)絕熱材料地導(dǎo)熱系數(shù)?密度?吸水率等技術(shù)性能參數(shù)進(jìn)行復(fù)驗(yàn),復(fù)驗(yàn)應(yīng)為見(jiàn)證取樣迭檢;檢驗(yàn)方法:現(xiàn)場(chǎng)隨機(jī)抽樣送檢;核查復(fù)驗(yàn)報(bào)告?檢查數(shù)量:同一廠家同材質(zhì)地絕熱材料復(fù)驗(yàn)次數(shù)不得少于 2次?空調(diào)系統(tǒng)冷熱源設(shè)備和輔助設(shè)備及其管網(wǎng)系統(tǒng)地安裝,應(yīng)符合下列規(guī)定:(1)管道系統(tǒng)地制式,應(yīng)符合設(shè)計(jì)要求;(2)各種設(shè)備?自控閥門與儀表應(yīng)按設(shè)計(jì)要求安裝齊全 ,不得隨意增減和更換;(3)空調(diào)冷(熱)水系統(tǒng),應(yīng)能實(shí)現(xiàn)設(shè)計(jì)要求地變流量或定流量運(yùn)行 ;(4)供熱系統(tǒng),應(yīng)能根據(jù)熱負(fù)荷及室外溫度地變化實(shí)現(xiàn)設(shè)計(jì)要求地集中質(zhì)調(diào)節(jié)?量調(diào)節(jié)或質(zhì)-量調(diào)節(jié)相結(jié)合地運(yùn)行?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?空調(diào)系統(tǒng)冷熱源和輔助設(shè)備及其管道和室外管網(wǎng)系統(tǒng),應(yīng)隨施工進(jìn)度與節(jié)能有關(guān)地隱蔽部位或內(nèi)容進(jìn)行驗(yàn)收,并應(yīng)有詳細(xì)地文字記錄和必要地圖像資料;檢驗(yàn)方法:觀察檢查;核查隱蔽工程驗(yàn)收記錄?檢查數(shù)量:全數(shù)檢查?冷熱源側(cè)地電動(dòng)兩通調(diào)節(jié)閥?水力平衡閥及冷(熱)量計(jì)量裝置等自控閥門與儀表地安裝,應(yīng)符合下列規(guī)定:(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求?(2)方向應(yīng)正確,位置應(yīng)便于操作和觀察?檢驗(yàn)方法:觀察檢查?檢查數(shù)量:全數(shù)檢查?6.鍋爐?熱交換器?電機(jī)驅(qū)動(dòng)壓縮機(jī)地蒸氣壓縮循環(huán)冷水 (熱泵)機(jī)組等設(shè)備-29-建筑節(jié)能工程監(jiān)理細(xì)則地安裝應(yīng)符合下列要求 :(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求;(2)安裝位置及管道連接應(yīng)正確 ?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?冷卻塔?水泵等輔助設(shè)備地安裝應(yīng)符合下列要求:(1)規(guī)格?數(shù)量應(yīng)符合設(shè)計(jì)要求;(2)冷卻塔設(shè)置位置應(yīng)通風(fēng)良好并應(yīng)遠(yuǎn)離廚房排風(fēng)等高溫氣體 ;(3)管道連接應(yīng)正確?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?輸送介質(zhì)溫度低于周圍空氣露點(diǎn)溫度地管道,當(dāng)采用非閉孔性絕熱材料絕熱時(shí),其防潮層和保護(hù)層必須完整,且封閉良好?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?空調(diào)系統(tǒng)地冷熱源和輔助設(shè)備及其管網(wǎng)系統(tǒng)安裝完畢后,系統(tǒng)試運(yùn)轉(zhuǎn)及調(diào)試必須符合下列規(guī)定:(1)冷熱源和輔助設(shè)備必須進(jìn)行單機(jī)試運(yùn)轉(zhuǎn)及調(diào)試 ;(2)冷熱源和輔助設(shè)備必須同建筑物內(nèi)空調(diào)系統(tǒng)進(jìn)行聯(lián)合試運(yùn)轉(zhuǎn)及調(diào)試;(3)聯(lián)合試運(yùn)轉(zhuǎn)及調(diào)試結(jié)果應(yīng)符合設(shè)計(jì)要求 ,并應(yīng)符合《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411-2007第11.2.1l 條地規(guī)定?檢驗(yàn)方法:觀察檢查;核查試運(yùn)轉(zhuǎn)和調(diào)試記錄?檢驗(yàn)數(shù)量:全數(shù)檢查?空調(diào)系統(tǒng)地冷熱源設(shè)備及其輔助設(shè)備?配件地絕熱,不得影響其操作功能?檢驗(yàn)方法:觀察檢查?檢驗(yàn)數(shù)量:全數(shù)檢查?-30-建筑節(jié)能工程監(jiān)理細(xì)則第七節(jié) 配電與照明節(jié)能工程(一)一般規(guī)定建筑配電與照明節(jié)能工程驗(yàn)收地檢驗(yàn)批劃分應(yīng)按《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411-2007第3.4.1條地規(guī)定執(zhí)行?當(dāng)需要重新劃分檢驗(yàn)批時(shí),可按照系統(tǒng)?樓層?建筑分區(qū)劃分若干個(gè)檢驗(yàn)批;建筑配電與照明節(jié)能工程地施工質(zhì)量驗(yàn)收,應(yīng)符合《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB504l1-2007 和《建筑電氣工程施工質(zhì)量驗(yàn)收規(guī)范》 GB50303-2002地有關(guān)規(guī)定?己批準(zhǔn)地設(shè)計(jì)圖紙?合同約定地內(nèi)容和相關(guān)技術(shù)規(guī)定進(jìn)行?(二)配電與照明節(jié)能工程質(zhì)量控制照明光源?燈具及其附屬裝置地選擇必須符合設(shè)計(jì)要求,當(dāng)設(shè)計(jì)無(wú)要求時(shí),應(yīng)符合《建筑照明設(shè)計(jì)標(biāo)準(zhǔn)》GB50034地相關(guān)規(guī)定?除滿足上述規(guī)定外,安裝前還應(yīng)符合下列要求:(1)鎮(zhèn)流器自身功耗不大于光源標(biāo)稱功率地 15%,諧波含量不大于 20%?(2)氣體放電燈地整體功率因數(shù)不得低于 0.9?檢驗(yàn)方法:現(xiàn)場(chǎng)使用數(shù)字功率計(jì)檢測(cè) ?檢查數(shù)量:同批次同規(guī)格數(shù)量超過(guò) 100套時(shí)抽查l%,不足100套時(shí)檢查數(shù)量不小于1套?低壓配電系統(tǒng)選擇地電纜?電線截面不得低于設(shè)計(jì)值,進(jìn)場(chǎng)時(shí)應(yīng)對(duì)其截面和每芯導(dǎo)體電阻值進(jìn)行見(jiàn)證取樣送檢?每芯導(dǎo)體電阻值應(yīng)符合下表地規(guī)定-31-建筑節(jié)能工程監(jiān)理細(xì)則不同標(biāo)稱截面地電纜?電線每芯導(dǎo)體最大電阻值標(biāo)稱界面220℃時(shí)導(dǎo)體最大電阻(Ω/km)(mm)圓銅導(dǎo)體(不鍍金屬)0.536.00.7524.51.018.11.512.12.57.4144.6163.08101.83161.15250.727350.524500.387700.268950.1931200.1531500.1241850.09912400.7543000.0601檢驗(yàn)方法:進(jìn)場(chǎng)時(shí)抽樣送檢,驗(yàn)收時(shí)核查檢驗(yàn)報(bào)告?檢查數(shù)量:同廠家各種規(guī)格總數(shù)地 10%,且不少于2個(gè)規(guī)格?在工程安裝完成后,應(yīng)對(duì)低壓配電系統(tǒng)進(jìn)行調(diào)試,調(diào)試合格后應(yīng)對(duì)低壓配電電源質(zhì)量進(jìn)行檢測(cè)?其中:(1)供電電壓允許偏差:三相供電電壓允許偏差為標(biāo)稱系統(tǒng)電壓地± 7%,單相220V為+7%?-10%;(2)公共電網(wǎng)諧波電壓限值為 :380V地電網(wǎng)標(biāo)稱電壓,電壓總諧波畸變率(THDu)為5%,奇次(1~25次)諧波含有率為4%,偶次諧波含有率為2%;(3)諧波電流不應(yīng)超過(guò)《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411-2007第12.2.3條規(guī)定地允許值;(4)三相電壓不平衡度允許值為 2%,短時(shí)不得超過(guò)4%?檢驗(yàn)方法:在己安裝地變頻和照明設(shè)備等可產(chǎn)生諧波地用電設(shè)備均可投入地情況下,使用三相電能質(zhì)量分析儀在變壓器地低壓側(cè)測(cè)量?-32-建筑節(jié)能工程監(jiān)理細(xì)則檢查數(shù)量:全部檢測(cè)在通電試運(yùn)行中,測(cè)試記錄照明系統(tǒng)地照度和功率密度值:(1)照度值不得小于設(shè)計(jì)值地 90%?(2)功率密度值不得大于《建筑照明設(shè)計(jì)標(biāo)準(zhǔn)》 GB50034-2004中地規(guī)定?檢驗(yàn)方法:在無(wú)外界光源地情況下,檢測(cè)被檢區(qū)域內(nèi)平均照度和功率密度 ?檢查數(shù)量:每種功能區(qū)至少檢查 1處?母線與母線或母線與電器接線端子,當(dāng)采用螺栓搭接連接時(shí)應(yīng)采用力矩扳手?jǐn)Q緊,制作應(yīng)符合《建筑電氣工程施工質(zhì)量驗(yàn)收規(guī)范》 GB50303標(biāo)準(zhǔn)中地有關(guān)規(guī)定;檢驗(yàn)方法:使用力矩扳手對(duì)壓接螺栓進(jìn)行力矩檢測(cè) ?檢查數(shù)量:母線按檢驗(yàn)批抽查 10%?交流單芯電纜或分相后地每相電纜宜按品字型(三葉型)敷設(shè),且不得形成閉合鐵磁回路;檢驗(yàn)方法:觀察檢查?檢查數(shù)量:全數(shù)檢查?三相照明配電干線地各相負(fù)荷宜分配平衡,其最大相負(fù)荷不宜超過(guò)三相負(fù)荷平均值地115%,最小相負(fù)荷不宜小于三相負(fù)荷平均值地85%;檢驗(yàn)方法:在建筑物照明通電試運(yùn)行時(shí)開(kāi)啟全部照明負(fù)荷,使用三相功率計(jì)檢測(cè)各相負(fù)載電流?電壓和功率?檢查數(shù)量:全部檢查?-33-建筑節(jié)能工程監(jiān)理細(xì)則第八節(jié) 監(jiān)測(cè)與控制節(jié)能工程(一)一般規(guī)定監(jiān)測(cè)與控制系統(tǒng)施工質(zhì)量地檢測(cè)和驗(yàn)收應(yīng)執(zhí)行《智能建筑工程質(zhì)量驗(yàn)收規(guī)范》GB50339相關(guān)章節(jié)地規(guī)定?建筑節(jié)能工程監(jiān)測(cè)與控制系統(tǒng)地施工驗(yàn)收應(yīng)以智能建筑地建筑設(shè)備監(jiān)控系統(tǒng)為基礎(chǔ)進(jìn)行施工驗(yàn)收;監(jiān)測(cè)與控制系統(tǒng)驗(yàn)收地主要對(duì)象應(yīng)為通風(fēng)與空氣調(diào)節(jié)和配電與照明所采用地監(jiān)測(cè)與控制系統(tǒng),能耗計(jì)量系統(tǒng)以及建筑能源管理系統(tǒng);監(jiān)測(cè)與控制系統(tǒng)地施工驗(yàn)收分為工程實(shí)施和系統(tǒng)檢測(cè)兩個(gè)階段?工程實(shí)施過(guò)程檢查由施工單位和監(jiān)理單位隨工程實(shí)施過(guò)程進(jìn)行,分別對(duì)施工質(zhì)量管理文件?設(shè)計(jì)符合性?產(chǎn)品質(zhì)量?安裝質(zhì)量進(jìn)行檢查,對(duì)隱蔽工程及相關(guān)接口進(jìn)行隨工檢查,同時(shí),應(yīng)有詳細(xì)地文字和圖像資料,并對(duì)監(jiān)測(cè)與控制系統(tǒng)進(jìn)行不少于168小時(shí)地不間斷試運(yùn)行?系統(tǒng)檢測(cè)內(nèi)容應(yīng)包括對(duì)工程實(shí)施文件和系統(tǒng)自檢文件地復(fù)核,對(duì)監(jiān)測(cè)與控制系統(tǒng)地安裝質(zhì)量?系統(tǒng)節(jié)能監(jiān)控功能?能源計(jì)量及建筑能源管理等進(jìn)行檢查和檢測(cè)?系統(tǒng)檢測(cè)內(nèi)容分為主控項(xiàng)目和一般項(xiàng)目,系統(tǒng)檢測(cè)內(nèi)容結(jié)果是監(jiān)測(cè)與控制系統(tǒng)地驗(yàn)收依據(jù)?對(duì)不具備試運(yùn)行條件地項(xiàng)目,應(yīng)在審核調(diào)試記錄地基礎(chǔ)上進(jìn)行模擬檢測(cè),以檢測(cè)監(jiān)測(cè)與控制系統(tǒng)地節(jié)能監(jiān)控功能?(二)監(jiān)測(cè)與控制節(jié)能工程質(zhì)量控制監(jiān)測(cè)與控制系統(tǒng)采用地設(shè)備?材料及附屬產(chǎn)品進(jìn)場(chǎng)時(shí),應(yīng)按照設(shè)計(jì)要求對(duì)其品種?規(guī)格?型號(hào)?外觀和性能等進(jìn)行檢查驗(yàn)收,經(jīng)監(jiān)理工程師檢查認(rèn)形成相應(yīng)地質(zhì)量記錄?各種設(shè)備?材料和產(chǎn)品附帶地質(zhì)量證明文件和相關(guān)技術(shù)資料應(yīng)齊全,并應(yīng)符合國(guó)家現(xiàn)行有關(guān)標(biāo)準(zhǔn)和規(guī)定 ?檢驗(yàn)方法:進(jìn)行外觀檢查;對(duì)照設(shè)計(jì)要求核查質(zhì)量證明文件和相關(guān)技術(shù)資料?檢查數(shù)量:統(tǒng)全數(shù)檢查?監(jiān)測(cè)與控制系統(tǒng)安裝質(zhì)量重點(diǎn)檢查以下內(nèi)容:(1)傳感器地安裝質(zhì)量應(yīng)符合《自動(dòng)化儀表工程施工及驗(yàn)收規(guī)范》 GB-34-建筑節(jié)能工程監(jiān)理細(xì)則50093地有關(guān)規(guī)定;(2)閥門型號(hào)和參數(shù)應(yīng)符合設(shè)計(jì)要求 ,其安裝位置?閥前后直管段長(zhǎng)度 ?流體方向等應(yīng)符合產(chǎn)品安裝要求 ;(3)壓力和差壓儀表地取壓點(diǎn) ?儀表配套地閥門安裝應(yīng)符合產(chǎn)品要求 ;(4)流量?jī)x表地型號(hào)和參數(shù)?儀表前后地直管段長(zhǎng)度等應(yīng)符合產(chǎn)品要求 ;(5)溫度傳感器地安裝位置?插入深度應(yīng)符合產(chǎn)品要求 ;(6)變頻器安裝位置?電源回路敷設(shè)?控制回路敷設(shè)應(yīng)符合設(shè)計(jì)要求 ;(7)涉及節(jié)能控制地關(guān)鍵傳感器應(yīng)預(yù)留檢測(cè)孔或檢測(cè)位置,管道保溫時(shí)應(yīng)做明顯標(biāo)注?檢驗(yàn)方法:對(duì)照?qǐng)D紙或產(chǎn)品說(shuō)明書目測(cè)和尺量檢查 ?檢查數(shù)量:每種儀表按20%抽檢,不足10臺(tái)全部檢查?對(duì)經(jīng)過(guò)試運(yùn)行地項(xiàng)目,其系統(tǒng)地投入情況?監(jiān)控功能?故障報(bào)警連鎖控制及數(shù)據(jù)采集等功能,應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:調(diào)用節(jié)能監(jiān)控系統(tǒng)地歷史數(shù)據(jù) ?控制流程圖和試運(yùn)行記錄 ,對(duì)數(shù)據(jù)進(jìn)行分析?檢查數(shù)量:檢查全部進(jìn)行過(guò)試運(yùn)行地系統(tǒng) ?空調(diào)冷熱源?空調(diào)水地監(jiān)測(cè)控制系統(tǒng)應(yīng)成功運(yùn)行,控制及故障報(bào)警功能應(yīng)符合設(shè)計(jì)要求?檢驗(yàn)方法:在中央工作站使用檢測(cè)系統(tǒng)軟件 ,或采用在直接數(shù)字控制器或冷熱源系統(tǒng)自帶控制器上改變參數(shù)設(shè)定值和輸入?yún)?shù)值 ,檢測(cè)控制系統(tǒng)地投入情況及控制功能 ;在工作站或現(xiàn)場(chǎng)模擬故障 ,檢測(cè)故障監(jiān)視?記錄和報(bào)警功能?檢查數(shù)量:全部檢測(cè)?5.通風(fēng)與空調(diào)地監(jiān)測(cè)控制地控制功能及故障報(bào)警功能應(yīng)符合設(shè)計(jì)要求 :檢驗(yàn)方法:在中央工作站使用檢測(cè)系統(tǒng)軟件 ,或采用在直接數(shù)字控制器或通風(fēng)與空調(diào)系統(tǒng)自帶控制器上改變參數(shù)設(shè)定值和輸入?yún)?shù)值 ,檢測(cè)控制系統(tǒng)地投入情況及控制功能 ;在工作站或現(xiàn)場(chǎng)模擬故障,檢測(cè)故障監(jiān)視?記錄和報(bào)警功能?檢查數(shù)量:按總數(shù)地20%抽樣檢測(cè),不足5臺(tái)全部檢測(cè)?-35-建筑節(jié)能工程監(jiān)理細(xì)則監(jiān)測(cè)與計(jì)量裝置地檢測(cè)計(jì)量數(shù)據(jù)應(yīng)準(zhǔn)確,并符合系統(tǒng)對(duì)測(cè)量準(zhǔn)確度地要求;檢驗(yàn)方法:用標(biāo)準(zhǔn)儀器儀表在現(xiàn)場(chǎng)實(shí)測(cè)數(shù)據(jù) ,將此數(shù)據(jù)分別與直接數(shù)字控制器和中央工作站顯示數(shù)據(jù)進(jìn)行比對(duì) ?檢查數(shù)量:按20%抽樣檢測(cè),不足10臺(tái)全部檢測(cè)?供配電地監(jiān)測(cè)與數(shù)據(jù)采集系統(tǒng)應(yīng)符合設(shè)計(jì)要求
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年玉林貨運(yùn)從業(yè)資格仿真考題
- 2024商標(biāo)轉(zhuǎn)讓及品牌升級(jí)合同:攜手共進(jìn)品牌升級(jí)之旅3篇
- 2024商混合同范本:商混混凝土生產(chǎn)與質(zhì)量控制合作協(xié)議3篇
- 2025廚房設(shè)備銷售合同版
- 商業(yè)綜合體電力施工合同范本
- 城市公園旁咖啡館租賃合同
- 城市綠化帶擴(kuò)建植樹合同
- 出入境文件公證辦理規(guī)范
- 智能家居維修員招聘合同模板
- 汽車研發(fā)中心施工協(xié)議
- 【道法廣角】成語(yǔ)故事會(huì):立木為信
- 《我們?nèi)タ春!烽喿x答案
- 智慧酒店無(wú)人酒店綜合服務(wù)解決方案
- 考研英語(yǔ)一新題型歷年真題(2005-2012)
- 健身房會(huì)籍顧問(wèn)基礎(chǔ)培訓(xùn)資料
- 9脊柱與四肢、神經(jīng)系統(tǒng)檢查總結(jié)
- 秀場(chǎng)內(nèi)外-走進(jìn)服裝表演藝術(shù)智慧樹知到答案章節(jié)測(cè)試2023年武漢紡織大學(xué)
- 【高分復(fù)習(xí)筆記】王建《現(xiàn)代自然地理學(xué)》(第2版)筆記和課后習(xí)題詳解
- TSGD0012023年壓力管道安全技術(shù)監(jiān)察規(guī)程-工業(yè)管道(高清晰版)
- SMM英國(guó)建筑工程標(biāo)準(zhǔn)計(jì)量規(guī)則中文 全套
- 2023-2024學(xué)年浙江省富陽(yáng)市小學(xué)數(shù)學(xué)四年級(jí)上冊(cè)期末通關(guān)題
評(píng)論
0/150
提交評(píng)論