分析故障點的故障分量電流電壓相量圖的關系王繼弘1 ,李仲明2 (1.華電湖南石門發(fā)電有限公司,湖南 石門 415300 2.寧夏電力公司,寧夏 銀川 750001)摘要: 由于故障分量原理在微機保護中大量應用,而故障分量存在于故障分量網絡中,因此有必要建立短路故障時故障分量網絡,畫出在故障點電流、電壓故障分量相量圖。按對稱分量概念,求其故障點各序電流、電壓,以便理解故障分量原理的微機保護。關鍵詞:故障分量;電流;電壓;相量圖Analysising the Relationship of fault points fault component current and voltage vector diagramWANG Ji-hong,LI Zhong-ming(1. Central China Electric Power Hunan Shimen Electric Generation Limited Company, Shimen 415300,China;2.Ningxia Electric Power Corporation, Yinchuan750001,China)Abstract: Because of fault component Principle applies in microcomputer protection massively, but fault component exists in fault component network, so it is necessary to build the fault component network of short fault, draw the fault points current and voltage vector diagram. According to the symmetrical component conception, asking the fault points sequence current and voltage, so that understanding the microcomputer protection of fault component principle.Key words: fault component; current; voltage; vector diagram40 引言應用對稱分量法分析不對稱短路故障時,一種是將不對稱短路形成的不對稱電流、電壓分解為正序、負序、零序三組對稱的系統(tǒng);另一種是當電力系統(tǒng)某點發(fā)生不對稱短路故障時,看成是在原有三相對稱系統(tǒng)上,原有的電源電動勢M=0, N=0,在故障K點反向接入正常運行電壓,可以分解為正序、負序、零序分量。稱為故障分量亦稱為突變量。在短路故障分析中,要選出特殊(基準)相指的是故障處與兩相情況不同的那一相;同一類型短路故障發(fā)生在不同相別上時,特殊相的序分量邊界條件不變,于是短路特性不變;故障點的正序網絡、負序網絡、零序網絡與故障類型、故障相別無關;但各序網絡合成的復合序網與短路故障類型、相別有關,復合序網指的是特殊相的。故障點故障相電流絕對值I與故障支路的正序分量電流I成正比。高壓電網中發(fā)生短路故障時有Z1=Z2時,兩相短路電流等于同一點三相短路電流的2,當Z1=Z2=Z0時,I=I=I;當Z0Z1時,有II,II;當Z0=Z1時,有I=I,I=I;當Z0Z1時,有II,II;在故障點或母線上的正序電壓有如下的關系:UUUU;越靠近電源,正序電壓數值越高。對于負序電壓和零序電壓(或故障分量電壓)的分布,故障點最高,離故障點愈遠、數值愈低。1 三相短路K(3)故障分量分析K點三相短路,在故障分量網絡中K點僅有反向接入正常運行電壓、造成,原有電源電動勢M=0,N=0;因三相對稱,只需畫出A相即可,如圖1所示。K點三相短路故障時的故障分量的邊界條件為:=-;=-;=-K點序電壓的故障分量的邊界條件為:=-a(-)a2(-)=-=-a2(-)a(-)=0=-(-)(-)=0=-/Z1=/Z1 =0; =0K點三相短路故障時故障分量電壓、電流相量圖如圖2所示,其正序電壓分布圖如圖3所示。2 兩相接地短路K(1.1) 故障分量分析K點BC相接地短路時,在K點反向接入正常運行電壓、 造成,原有電源電動勢M=0, N=0的情況下,即在故障分量電壓-、-作用下,在其K點BC相接地短路時故障分量網絡如圖4所示,在K點BC相接地短路故障分量的邊界條件為:=0; =-;=-ZM1M MA ZMK1 K ZNK1 NA NMAZN1NA-+圖1 K點三相短路故障時的故障分量網絡Fig1 Fault component network of k points three-phase short circuit faultkA0在故障分量網絡中建立相應的故障分量正序、負序、零序電壓、電流;用特殊相A相序分量表示,可得序電壓、電流邊界條件方程式如下 :=0-= -=-=圖2 K點三相短路故障時的故障分量電壓、電流 相量圖Fig2 Fault component current and volage vector diagram of k points three-phase short circuit faultKOUMAUNAMKN-U(a)故障分量電壓分布 (a)Voltage set of fault componentUMAUNA(b)總的正序電壓分布(b)All set of positive sequence voltage圖3 K點三相短路故障時的正序電壓分布Fig3 Positive sequence voltage set of k points three-phase short circuit faultZM1 M ZMK1 K ZNK1 N ZN1ZN1ZM1ZM1ZMK1 ZNK1MCZMK1ZNK1NCZN1NBMBgNCMBNBMC圖4 BC相接地時的故障分量網絡Fig4 Fault component network of BC two-phase grounding fault=a2a=-(a2Z1aZ2Z0)=- =aa2=-(aZ1a2Z2Z0)=-將上三方程聯(lián)合求解,得到=/Z1Z2 Z0/(Z2Z0)=-Z0/(Z2Z0)=-Z2/(Z2Z0)又=-Z1=-Z1/Z1Z2 Z0/(Z2Z0)當Z1=Z2時,=-(Z1Z0)/(Z22Z0)=-Z2=-Z1-Z0/(Z2Z0)當Z1=Z2時,=-Z0/(Z1Z0)=Z0/(Z12Z0)=-Z0=-Z0-Z2/(Z2Z0)當Z1=Z2時, =-Z0/(Z1Z0)=Z0/(Z12Z0)可見: 與大小相等, 相位相同,與反相位。=(Z0-Z1)/(Z12Z0)0(Z0Z1時)將、代入、中,可得:=-、=-表示分析無誤。根據上述計算分析,可作出故障分量復合序網如圖5所示,有關故障點故障分量電壓、電流相量如圖6所示,顯而易見,故障分量的負序網絡、零序網絡與原有的負序網絡、零序網絡相同,兩相短路K(2)、單相接地短路K(1)故障分量分析,方法類同,在此不贅。Z1Z2K1N1K2N2無源網絡Z0K0N0圖5 BC相接地時的故障分量復合序網Fig5 Fault component compound sequence network of BC two-phase grounding fault(a) 電壓故障分量相量圖(a) Voltage fault component vector diagram (Z0Z1時)3(b)電流故障分量相量圖(b) Current fault component vector diagram圖6 BC相接地短路時故障分量相量圖Fig6 Fault component vector diagram of BC two-phase grounding fault圖中示出的是Z0Z1情況120;當Z0=Z1時,(a)圖中=0;(b)圖中120;當Z0Z1時,(a)圖中反向;(b)圖中120。3 結論3.1求故障分量的步驟:3.1.1列出故障分量的邊界條件。3.1.2根據邊界條件求出特殊相序分量特點,作出故障分量復合序網。3.1.3根據復合序網可求出電網中各支路、各節(jié)點電流、電壓故障分量,并可求出規(guī)律性特點(繼電保護中用)。3.1.4根據復合序網,可方便求得故障分量電流、電壓相量圖之間的關系。3.1.5由故障分量邊界條件的全電壓、全電流與其邊界條件的序電壓、序電流應用解析式與相量圖關系互為驗證其分析的準確性。3.2對在K點發(fā)生K(3)、K(2)、K(1)、K(1.1)短路故障時故障分量電流、電壓有如下結論:3.2.1故障點的短路電流就是故障分量電流。3.2.2故障點的負序、零序分量電流、電壓就是故障分量負序、零序電流、電壓。3.2.3故障點的正序分量電流、電壓與故障分量正序電流、電壓不同。3.2.4在分析故障分量時,正序、負序、零序網絡均是無源網絡,故有如下關系式:=-Z1; KA1=-kA1Z1 =-Z2=KA2=-kA2Z2 =-Z0=KA0=-kA0Z0kA1=; kA2=; kA0=為分析方便,角標右上角帶“”表示故障分量。參考文獻1 王梅義.高壓電網繼電保護運行.北京電力工業(yè)出版社,1981年.王梅義.電網繼電保護應用.北京電力出版社,1999年.WANG Mei-yi. Relay Protection Running of High Electric Power System.Beijing Electric Power Industry Press,1981.WANG Mei-yi.Application of Electric Power System Relay Protection.Beijing Electric Power Press,1999.2 朱聲石.高壓電網繼電保護原理與技術第三版.電力出版社,2005年.ZHU Sheng-shi. The Third Edition of High Electric Power System Relay Protection Principle and Technology. Electric Power Press,2005.3 江蘇省電力公司編電力系統(tǒng)繼電保護原理與實用技術.電力出版社,2006年.Electric Power System Relay Protection Principle and Practical Technology written by Jiangsu Electric Power C

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論