1、壓力式泡沫比例混合裝置(型號: PHYM24/10 、PHYM24/15 、PHYM32/20 、PHYM32/25 、PHYM32/30 、PHYM48/40 、PHYM48/50 、PHYM48/55 、PHYM64/60 、PHYM64/76 、PHYM64/80 、PHYM80/100 、PHYM100/110、PHYM120/130)使用說明書制造商:渤盾消防設備地址:市津南區(qū)小站工業(yè)園: 8傳真: 3郵編: 300353目錄一、概述············

2、3;·······································1二、產(chǎn)品規(guī)格及型號·········

3、·································2三、結(jié)構(gòu)及工作原理· ··············&

4、#183;··························2 四、性能參數(shù)與結(jié)構(gòu)尺寸· ····················

5、;·················3 五、安 裝·······························

6、3;··················5六、使用方法······························

7、83;·················5七、維護和保養(yǎng)·······························&

8、#183;··············7八、故障排除··································

9、··············7九、保修圍···································

10、·············7一、概述PHYM 系列壓力式泡沫比例混合裝置由泡沫罐、壓力式比例混合器、隔膜、進水管、出液管及控制閥等組成。當壓力水流經(jīng)該裝置的比例混合器時,能使水與泡沫按一定的比例進行自動混合,輸出泡沫混合液供泡沫產(chǎn)生器、泡沫槍、泡沫炮等噴射設備產(chǎn)生噴射空氣泡沫進行滅火。該裝置可與消防泵(或消防車) 、泡沫產(chǎn)生及噴射設備組成固定式(或半固定式)泡沫滅火系統(tǒng)(見圖一)。廣泛用于撲滅甲(液化烴除外) 、乙、丙類液體火災,具有安全可靠、滅火效率高等優(yōu)點,是油

11、庫、煉油廠、化工廠、油田、碼頭、油輪、飛機庫、機場及燃油鍋爐房等場所最普遍配置使用的消防設備。圖一、 PHYM 系列泡沫滅火示意圖二、產(chǎn)品規(guī)格及型號PHYM 系列貯罐壓力式泡沫比例混合裝置按填盛方式分隔膜式、普通型;按罐體放置方式分臥式、立式兩種形式。泡沫混合比一般為3%或 6%,亦可提供 8%的混合液用于中倍數(shù)泡沫滅火系統(tǒng)。該裝置混合液流量32-160L/s,貯罐容積有1000-15000L 不同規(guī)格。根據(jù)所需要的混合液流量和泡沫噴射時間,比例混合器和泡沫罐可任意組合成系列產(chǎn)品,以滿足工程應用的需要。PHYM 系列貯罐壓力式泡沫比例混合裝置的型號意義標記示例: PHYM32/55-6表示最大

12、流量為32L/S,泡沫液儲罐容積為5.5M 3,混合比為 6%的隔膜型壓力式比例混合裝置。三、結(jié)構(gòu)及工作原理PHYM 系列貯罐壓力式泡沫比例混合裝置采用貯罐,比例混合器組合形式,由罐體(普通型或隔膜型)、混合器總成、進水管路總成、出水管總成,排液管總成等組成。當消防水泵的壓力水沿供水管道進入比例混合器時,一小部分壓力經(jīng)進水管道流入泡沫液貯罐,將罐(或隔膜)的泡沫液壓出,泡沫液通過出液管道進入壓力比例混合器,在混合器中與水按規(guī)定的比例形成混合液流出混合器,再通過混合液管被送入泡沫產(chǎn)生設備,噴射泡沫進行滅火 (見圖二)。該裝置中設定為水壓超過 1.26MPa 時即能自動泄壓, 以保持裝置安全。普通

13、型:由于溢水環(huán)安裝在罐件的最上方,進入管路流入罐的壓力水能從罐上方緩緩流出,水與泡沫液不會快速攪拌,保持比重大于水的泡沫藥劑始終在水的下方,以滿足比例混合器按比例使泡沫液與水的混合要求。隔膜式貯罐:由于貯罐帶有高強度橡膠膜,在使用過程中所貯存的泡沫原液不與水接觸,每次使用后所剩的泡沫原液不會失效。此外性能穩(wěn)定的橡膠膜也可以貯存各類輕水泡沫原液。此外性能穩(wěn)定的橡膠膜也可以貯存各類輕水泡沫原液。圖二 PHYM 系列(隔膜型)壓力式比例混合裝置工作原理圖四、性能參數(shù)與結(jié)構(gòu)尺寸PHY/PHYM 系列壓力式比例混合裝置性能參數(shù)表最大工作壓最大混混 合 液混合比壓力降儲罐形型號工作力力圍合液流流 量 圍(

14、%)( MPa)容積式( MPa)( MPa)量( L/s) (L/s)( L)PHYM24/10244-241000PHYM24/154-241500PHYM32/20324-322000PHYM32/25324-322500PHYM32/30324-323000PHYM48/404812-484000固PHYM48/504812-4850001.20.61.23 或 6 0.15定PHYM48/554812-485500式PHYM64/606416-646000PHYM64/766416-647600PHYM64/806416-648000PHYM80/1008016-8010000PHY

15、M100/11010025-10011000PHYM120/13012025-12013000PHY/PHYM (臥式)壓力式比例混合裝置外形及安裝尺寸表表 2型號DNLL1L2L3L4HH1BB1B2B3進、出口法蘭HG20593-97PHYM24/101000195040580030067018358551275660760650PN1.6/DN100PHYM24/1510002425525105030067018358551275660760650PN1.6/DN100PHYM32/2012002325475105035591519209001630720880795PN1.6/DN15

16、0PHYM32/2512002800640120035591519209001630720880795PN1.6/DN150PHYM32/30140026005401050400960215090018008401000870PN1.6/DN150PHYM48/40140032506651450400960215090018008401000870PN1.6/DN150PHYM48/50160031706901450800151023901100210096011201000PN1.6/DN200PHYM48/551600352091014508001510239011002100960112

17、01000PN1.6/DN200PHYM64/60160037208601650800151023901100210096011201000PN1.6/DN200PHYM64/761800365091515008001510266011502300112012801100PN1.6/DN200PHYM64/802000326074014507001510298511502530126014201235PN1.6/DN200PHYM80/1002000386094016506501465298511502605126014201260PN1.6/DN250PHYM100/110200041701

18、04017606501465298511502605126014201260PN1.6/DN250PHYM120/13022004180106517006501465318511502805138015801365PN1.6/DN250五、安裝1、PHYM 系列貯罐壓力式泡沫比例混合裝置應按照本說明書的安裝尺寸,用地腳螺栓穩(wěn)固地固定在混凝土基礎上,本裝置最好安裝在室。2、進出水管道按本裝置進出水法蘭尺寸進行連接。3、放水管長度根據(jù)已有的建筑設施、下水道位置等現(xiàn)場自定。4、安裝完畢后,應進行一次系統(tǒng)密封性試驗,貯液罐和管道不允許有滲漏現(xiàn)象,安全閥不能失靈。六、使用方法(一)使用條件1、與混合裝置

19、配套的消防水泵的壓力必須達到混合器進口工作壓力的要求。2、本裝置的工作壓力圍為0.6-1.2MPa,不能超出規(guī)定使用圍使用,否則將影響混合比,降低泡沫質(zhì)量。3、混合裝置在標定的工作壓力圍使用的壓力大小,取決與所配用的泡沫滅火設備的工作壓力和管道當量長度的摩阻損失。4、在備用狀態(tài)時,混合器中所有閥門應為關閉狀態(tài)。(二)普通型貯罐壓力式泡沫比例混合裝置使用方法(無隔膜型)1、泡沫液充裝首先打開排氣閥 C 和加液口法蘭蓋,由加液口進行人工充液(如用加液泵灌注泡沫液,需將加液泵與排液閥E 相聯(lián)即可)。當泡沫從灌裝口溢出時,即可停止充裝,并關閉閥C。2、使用(1) 正式使用時,(帶有泡沫液液位計的應首先

20、關閉液位計閥)開啟主管道閥門,主管道開始進水,當供水壓力達到所需壓力時,打開進水閥A ,觀看壓力表,當罐中壓力達到所需值時打開出液閥B,此時混合液即能按規(guī)定比例輸出進行滅火作業(yè)。(2) 停止工作時,將閥 A 、閥 B 關閉,打開排氣閥 C 泄壓,當壓力表復零時,打開排液閥 E,將罐剩余液體排盡,并關閉閥 C、閥 E。(3) 貯罐沖洗由于無隔膜貯罐在使用時,泡沫液已經(jīng)在貯罐與水混合,剩余泡沫液不能繼續(xù)使用。每次使用或做試驗后,剩余泡沫液應當全部放盡,并且對貯罐進行徹底清洗,才能重新充裝泡沫液。沖洗方法:關閉(閥 E)、(閥 B),開啟(閥 A )向罐充水,當充滿后,放置 810 小時,然后開啟(

21、閥 E)將水放盡,有條件時可用壓縮空氣將貯罐吹干,亦可以人工沖洗貯罐壁,干燥后重新充裝泡沫液。3、實驗時充裝泡沫液的方法:按以上第 3 條方法將貯罐充滿清水,開啟出氣閥(閥 C),打開法蘭蓋灌裝口向罐充入泡沫液,由于泡沫液比重大于清水,所以泡沫液充滿貯罐底部,而將多余的水從出氣閥擠出,每次試驗使用的泡沫液用量一般為貯罐容積的 1/4 左右,但最少不小于 500 升為宜。充完泡沫液后,即關閉全部閥門,試驗時的操作方法與同上。(三)隔膜型壓力式泡沫比例裝置使用方法1、起動消防水泵,并且管道有壓力水后,先打開進口閥及進水閥(閥A )。2、調(diào)節(jié)系統(tǒng)出口閥的開度,使壓力表顯示到泡沫比例混合裝置標定工作壓

22、力,并穩(wěn)定在一定數(shù)值。3、當貯罐進入壓力水并且壓力升到工作壓力后,即可打開出液閥(閥B)泡沫混合液自動調(diào)節(jié)到 6%或 3%的比例,并且開始向系統(tǒng)輸出泡沫混合液。4、當停止供液時,應先關閉出液閥(閥B)(以免壓力水倒灌液入泡沫液橡膠袋(然后關閉其它閥門。同時亦應終止水泵工作。5、初次灌泡沫液的方法:a)關閉(閥 D、 E),開啟(閥 C);b)打開泡沫液灌裝口法蘭蓋,可用人工向膠囊中加注泡沫液,亦可用電動加液泵從(閥E)向加注泡沫液;c)當泡沫液從灌裝口中溢出時,可認為泡沫液已注滿,關閉所有閥門。6、試水時,打開(閥A )、關閉(閥 D、E),通入壓力水,當排氣閥(閥C)噴出水后,即可關閉,使貯罐處于常備狀態(tài)。七、維護和保養(yǎng)1、 使用前必須先檢查“泡沫灌裝口”上法蘭蓋、連接管法蘭是否密封,各種閥門是否關閉。2、每使用完一次后必須用清水將貯罐和管道沖洗干凈,外表要進行補漆防腐處理。3、灌裝泡沫液時,應保持罐清潔,不得與油類或其它泡沫液相混,不應與老化的泡沫液混合使用,泡

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論