版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、XBR5 Implementation March 2011V0.53Estimated time: 40 minSchneider Electric internal use onlyXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Objectives & SummaryReview the range and implementation instructionsAble to Configure the Receiver Teach /
2、unteach buttons Set outputs Change functionsWhat Is Needed to Follow This Training A Programmable Receiver 2 Transmitter (2 push buttons) The XBR5 Simulator toolDownload SimulatorNextQuick Review of the OfferXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - Decembe
3、r 21Offer panoramaCatalog Package offer.XB5RMB03XB5RMA04XB5RFB01XB4RFB01“Package ready to use” In a package the transmitter has been paired to the receiver in the Schneider factory.Configurable receiver 1 complete button with dia 22mm plastic head 1 set of 10 caps1 programmable receiver with 2 relay
4、 outputs (24-240 VAC/DC)Non configurable receiver 1 complete button with dia 22mm plastic head 1 black cap1 receiver with 1 relay output (24 VDC)Non configurable receiver 1 complete button with dia 22mm plastic head 1 black cap1 receiver with 1 relay output (24 VDC)XB5RFA02XB4RFA02Configurable recei
5、ver 1 complete button with dia 22mm plastic head 1 set of 10 caps1 programmable receiver with 2 relay outputs (24-240 VAC/DC)Panel mountingmobile applicationNextXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Offer panoramaComponents offer.TransmitterM
6、etal headZB4RZA0plastic headZB5RZA0metal head with cap + TransmitterZB4RTAxxxZBRM01Push button + TransmitterZBRRCZBRRASatellite antenna24- 240v AC/DC supplyWhen needed, depending on the applicationPush button headsComplete push button ZBRT1 (*)Plastic head with cap + TransmitterZB5RTAxxxProgrammable
7、 receivers 4 PNP outputs 24 VDC supply 2 C/O relays outputs 24-240 VAC/DC supply(*) fixing collar ZB*Z009 must be ordered separatlyHandy box (empty)+ZBRA1Implementation and Front face IndicationXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Wiring of
8、ReceiversRelay output version: PNP output version :(1): For non configurable receiver the fuse is 125mANextXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Transmitter assemblyMounting : similar to Harmony rangeMetallic head ZB4BZ009Plastic head ZB5AZ00
9、9:XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Fixing the ReceiverScrewing mountingClipped on Rail DinXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Front Face IndicationNavigation / Selection in the
10、menusValidationLed status:Download Expert Instruction SheetStartSteady GreenBlinking GreenTeaching and ReceptionXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Teaching / UnteachingReminder: 32 (max number of transmitter per receiver)Teaching:Unteachin
11、gWith the transmitterWithout the transmitter (using ID number)Output 1 and / or Output 2X32 maxXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Typical distance transmitter / receiverApprox 100m* in free field* !Receiver in a metal cabinetRelay antennaA
12、pprox 40m*Receiver in a metal cabinetApprox 25m*The performances are the same whatever the used receiver.(*) Typical values that may be modified by the application environment(*) free field (unobstructed and no radio perturbation)(*) depending on the environment, the distance could be exceeding 40 m
13、XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Usage of a relay Antenna When If the signal strength LED on receiver is yellow Can be installed at any time to increase the reliability of transmission, in difficult environmentImplementation :Needs only
14、power supply, no settingsNot wired to the receiver or to the transmitterOne relay antenna can be used for one or several receivers / transmittersIt should be located in order to bypass obstaclesWorkshopsXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21W
15、hat Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEndOutput Mo
16、desMonostableBistableStart / StopXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 213 Output Modes / 2 Receivers TypeNon configurableOnly available in packages XB5RFB01 / XB4RFB01/ XB5RMB03 Ouput:1 relay COMonostableNo LED No buttonConfigurableIncluded in
17、 Packages : XB5RFA02 /XB4RFA02 / XB5RMA04And as Component ZBRRAOnly available as componentZBRRC Power Supply Monostable bistable output function Stop / start output function Buttons for parameterization Reception signal strength Q1, Q2, Q3, Q4 led for output signal Ouput:2 relays COOuputs:4 PNPNextX
18、BR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Output Mode: Monostable (manufacturing configuration)One click The output close during 500msNext500ms500ms500ms500ms500ms500ms500ms500ms500ms2 push buttons on the same output1 push button on the outputXBR5
19、 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21Output Mode: BistableFirst click The output closes Second click The output opensNext2 push buttons on the same relay output1 push button on the relay outputXBR5 ImplementationSchneider Electric | Industry Bus
20、iness | Training | E.Pauchet | - December 21Output Mode: Stop / Start (only recommended for simple functions, ie: switch On and Off a resistance)One transmitter closes the outputAn other transmitter opens the outputNext2 push buttons on the same relay outputXBR5 ImplementationSchneider Electric | In
21、dustry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Sta
22、rt Function#0: Discovering the Output ModesEnd#1 Teach a Button to Q1-Teach the Green Button to Q1-Q1 in MonostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#1 Teach Green Button to Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electri
23、c | Industry Business | Training | E.Pauchet | - December 21#1 Teach Green Button to Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#1 Teach Green Button to Q1: VideoThis video may tak
24、e some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#1 Teach Green Button to Q1: Your Turn!Back to MenuSee Simulator DemoDo it yourself !See Video DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric
25、| Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop /
26、 Start Function#0: Discovering the Output ModesEnd#2 Teach a Button to Q2-Teach the Red Button to Q2-Q2 in MonostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#2 Teach Red Button to Q2Steady GreenBlinking GreenXBR5 ImplementationSchneider Electri
27、c | Industry Business | Training | E.Pauchet | - December 21#2 Teach Red Button to Q2: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#2 Teach Red Button to Q2: VideoThis video may take so
28、me time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#2 Teach Red Button to Q2: Your Turn!Back to MenuDo it yourself !See Simulator DemoSee Video DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Indu
29、stry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start
30、 Function#0: Discovering the Output ModesEnd#3 Teach Additional Button to Q2-In addition to the Red Button, Teach the Blue Button to Q2-Q2 in MonostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#3 Teach Additional Button to Q2Steady GreenBlinking
31、 Green(In addition to the Red Button)XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#3 Teach Additional Button to Q2: SimulThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.P
32、auchet | - December 21#3 Teach Additional Button to Q2: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#3 Teach Additional Button to Q2Back to MenuDo it yourself !See Simulator DemoSee Vi
33、deo DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Rese
34、t#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#4: Unteach Button from Q1-Unteach Green button from Q1-Prerequisite: Green button already paired to Q1 (see exercise #1)XBR5 ImplementationSchneider Electric | Industry Business
35、 | Training | E.Pauchet | - December 21#4 Unteach a button from Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#4 Unteach a button from Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationS
36、chneider Electric | Industry Business | Training | E.Pauchet | - December 21#4 Unteach a button from Q1: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#4 Unteach a button from Q1: Your T
37、urn!Back to MenuSee Simulator DemoSee Video DemoDo it yourself !Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Loc
38、k the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#5: Lock the Receiver- Lock the receiverXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet |
39、 - December 21#5 Lock the ReceiverHardware lock:Software lock:XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#5: Lock the Receiver: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Busines
40、s | Training | E.Pauchet | - December 21#5: Lock the Receiver: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#5: Lock the Receiver: Your Turn!Back to MenuDo it yourself !See Simulator De
41、moSee Video DemoXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a But
42、ton from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#6 Unlock the Receiver- Prerequisite: receiver already locked (see exercise #5)XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#6 Unlock the Receive
43、rPress & HoldXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#6 Unlock the Receiver: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#6 U
44、nlock the Receiver: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#6 Unlock the Receiver: Your Turn!Press & HoldBack to MenuSee Simulator DemoSee Video DemoDo it yourself !XBR5 Imple
45、mentationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bista
46、ble Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#7 Set a Bistable Function- Set Q2 as Bistable-Prerequisite: Red push button already paired (see exercise #2)XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#7 Set Q2 as Bist
47、ableSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#7 Set Q2 as Bistable: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - Dec
48、ember 21#7 Set Q2 as Bistable: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#7 Set Q2 as Bistable: Your Turn!Steady GreenBlinking GreenBack to MenuSee Simulator DemoSee Video DemoDo it
49、yourself !XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button fr
50、om Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#8 Set a Stop / Start Function- Step1: Set Q1 as Stop / Start- Step2: Stop = Red Push Button- Step3: Start = Green Push ButtonXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pau
51、chet | - December 21#8-1: Set Stop / Start to Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#8-2: Assign Red Button to StopSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.
52、Pauchet | - December 21#8-3: Assign Green Button to StartSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#8-1: Set Stop / Start to Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider
53、 Electric | Industry Business | Training | E.Pauchet | - December 21#8-2: Set Stop to Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#8-3: Set Start Q1: SimulatorThis demo may take som
54、e time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#8: Test the Stop / Start FunctionThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | -
55、 December 21#8: Set Stop / Start to Q1: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21#8: Set Stop / Start to Q1. Your Turn!Back to MenuSee Simulator DemoSee Video DemoDo it yourself !XB
56、R5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - December 21What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: S
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025版?zhèn)€人房產(chǎn)買賣合同違約責(zé)任范本4篇
- 二零二五版智能倉儲物流系統(tǒng)安裝與優(yōu)化合同3篇
- 二零二五版環(huán)保節(jié)能改造項(xiàng)目工程合同4篇
- 2025年度個(gè)人房產(chǎn)交易安全評估及買賣合同大全3篇
- 2025年度留學(xué)學(xué)術(shù)誠信教育合同4篇
- 2025版企業(yè)職工失業(yè)保險(xiǎn)補(bǔ)貼資金支付合同3篇
- 2025年校園樂器維護(hù)保養(yǎng)及采購代理服務(wù)合同2篇
- 濟(jì)南2025版房屋買賣合同產(chǎn)權(quán)登記與稅務(wù)申報(bào)指南3篇
- 互聯(lián)網(wǎng)客服專員2025年度績效合同2篇
- 2025年度海洋運(yùn)輸貨物保險(xiǎn)合同保險(xiǎn)責(zé)任與保險(xiǎn)合同效力3篇
- 二零二五年度無人駕駛車輛測試合同免責(zé)協(xié)議書
- 2025年湖北華中科技大學(xué)招聘實(shí)驗(yàn)技術(shù)人員52名歷年高頻重點(diǎn)提升(共500題)附帶答案詳解
- 高三日語一輪復(fù)習(xí)助詞「と」的用法課件
- 毛渣采購合同范例
- 2023中華護(hù)理學(xué)會團(tuán)體標(biāo)準(zhǔn)-注射相關(guān)感染預(yù)防與控制
- 五年級上冊小數(shù)遞等式計(jì)算200道及答案
- 2024年廣東高考政治真題考點(diǎn)分布匯 總- 高考政治一輪復(fù)習(xí)
- 燃?xì)夤艿滥甓葯z驗(yàn)報(bào)告
- GB/T 44052-2024液壓傳動過濾器性能特性的標(biāo)識
- FZ/T 81013-2016寵物狗服裝
- JB∕T 14089-2020 袋式除塵器 濾袋運(yùn)行維護(hù)技術(shù)規(guī)范
評論
0/150
提交評論