




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)
文檔簡介
1、HP RSPforHP-UX ServerP 1.1Apr 09HP CONFIDENTIALRevision HistoryDateVersionDescriptionAuthor2008-10-23P1.0-1Document initiatedFrauke Denker 2008-12-31P1.0-2Draft version and Updates after review by RSP core teamZhouPeng2009-01-02P1.0-3Updates Troubleshooting section China RSP Techincal Core Team2009-
2、03-01P1.0-4Updates HP RSP datacenter IP/portChina RSP Techincal Core Team2009-03-01P1.1Updates HP RSP Webems configuration in CMS and RSP software 2009 Apr versionZhouPengRSP Core team memberNameMailTelRen,WeiDai,Feng-TaoZhou,PengHuang, Chen-YunNan,Guo-shun138106172201Scope.51.1.Resources51.2.Instal
3、lation Network issue61.3.Installation SIM&RSSWM step on CMS server(See SIM管理服務(wù)器及客戶端安裝配置手冊V1.0.pdf)61.4.Preparing HP-UX Managed Systems61.4.1.Removing HP ISEE from an HP-UX Managed System71.4.2.Removing WEBES from an HP-UX Managed System71.4.3.Removing the B.05.05 Advanced Configuration Collector
4、 (ACC) Software Package81.5.Installation Order81.5.1.Software minimum requirements for the installation of RSP81.6Installation of Diagnostics and Support Tools Software101.7Installation of OpenSSL software101.8Installation WBEMServices111.9Checking Requirements for SysFaultMgmt11.9.
5、.121.10Installation SysFaultMgmt Software121.11WBEM & SFM check and setup122.Setup System(s) for Remote Support Pack162.1Configuration Steps192.1.1.Set System properties (single servers)192.1.2.Create System properties task (for multiple systems)202.1.3.Check contract status222.1.4.Crea
6、ting WBEM subscription232.1.5.Verifying WBEM Subscription in CMS273.Installation of the Advanced Configuration Collector (ACC)343.1Installing Software343.2Exchanging certificates343.2.1.SIM Certificate353.2.2.Client Certificate353.3Preparation for the collection363.4Schedule and start a collection38
7、4.Useful Information404.1Diagnostic and SysFaultMgmt related processes404.2RSP related processes424.3HPUX directories and logs424.4Windows directories and logs425.Troubleshooting445.1System Fault Management445.2Remote Support Pack475.2.1.Cannot Connect to Server475.2.2.Invalid Hostname475.2.3.Bad Pr
8、oxy Server485.2.4.Proxy Authentication Information is Wrong485.2.5.SFM register&operation in HPUX client issue495.2.6.Use RSSM Local install issue:505.2.7.In SIM Configure Remote Support Configuration and Services output error one example:501 ScopeThis guide is designed to help you setting up th
9、e RSP including setup for SystemFaultManager & WBEMService for HP systems running HP-UX 11i. It is adaptable for both underlying CPU types PA-Risc and Itanium.And the HP Service Essentials Remote Support Pack Configuration & Usage Guide and CMS Troubleshooting Guide.Latest HP Service Essenti
10、als Remote Support Pack Configuration and Usage Guide can be found at:Latest HP Service Essentials Remote Support Pack CMS Troubleshooting Guide can be found at:This guide is intended for use by Response Center/GBIT, RSP Champions and DPEs only and is not for HP external customer consumption.1.1. Re
11、sources· HP Diagnostics and Support Tools Software· HP Diagnostics - Technical Documentation· HP-UX Linux HP WBEM Services for HP-UX and Linux System Administrator's Guide· Install OpenSSL· HP System Fault Management Software· HP Administrator's and User's G
12、uide for SFM· HP Release Notes for System Fault Manager· Checklist for troubleshooting problems with SysFaultMgmt· HP Service Essentials Remote Support Pack Configuration and Usage Guide· Service Essentials Remote Support Pack CMS Troubleshooting Guide· Internal Depot for SF
13、M Software incl. providers and other software needed to RSP1.2. Installation Network issueThe Software Manager on the CMS communicates over HTTPS/443. Likewise, the Remote Support Client component also communicates over HTTPS/443 to submit incidents to and retrieve ntitlement information from the HP
14、 Support Center. HTTPS provides encryption for confidentiality of software configuration data collected from the CMS and transferred to HP. Even though this chapter focuses on configuring RSSWM, it is advisable to configure your firewall for both communication channels (RSSWM and Remote Support Clie
15、nt)ServiceServer nameIP AddressHP Remote Support Software ManagerHP Remote Support Client15.RSSWM communicates directly with the HP Support Center through the firewall or web proxy server (if a web proxy server is in use). Remote Support RSSWM supports connecting directly to the Internet or connecti
16、ng through a proxy server and supports all proxy servers conforming to the HTTP/1.0 Specification. Remote Support Software Manager does not support proxies using proxy auto-configuration scripts, NTLM authentication (also known as Integrated Windows Authentication), or Kerberos authentication.For te
17、sting connectivity to the Software Management Server :443For testing connectivity to the monitoring data center Ther are the ouptput and notes the operation correctly and the datacenter versionNote:We have test some Proxy programs.HP recommend Linux SQUID and Windows ISAserver for Proxy programs.1.3
18、. Installation SIM&RSSWM step on CMS server(See )· Verify IIS is installed· Verify Internet Explorer Enhanced Security is NOT Enabled· Verify Java is installed on the CMS Browser· Insure Windows (DEP) Data Execution Prevention is Turned Off· Verify .Net framework 2.0 ins
19、talled· Verify SNMP trap service and SNMP service installed1.4. Preparing HP-UX Managed SystemsThese steps are required ONLY if you already have ANY version of the HP ISEE client or WEBES installed on an HP-UX managed system or if you are upgrading your HP-UX managed system from Service Essenti
20、als Remote Support Pack (RSP) version A.05.05 to A.0.1. Removing HP ISEE from an HP-UX Managed SystemThese steps are required ONLY if you already have HP Instant Support Enterprise Edition installed on your managed system. If you do not have ISEE installed on your managed system, you can ski
21、p this section.To remove ISEE, complete the following steps:1. Log on to the monitored system as root (admin privileges).2. Run the following command on each managed system:/usr/sbin/swremove ISEEPlatformIf the swremove process is successful, a message appears confirming the removal of the software.
22、 Check your log files to verify that there are no errors.If the swremove process does not complete successfully, consult the resulting log file. It may indicate that there are ISEE Platform dependencies that prevented success. Components such as VAEH, Availability Measure, or CCMon are optional Busi
23、ness Support Software components, but they must be removed before the ISEE Platform can complete uninstallation.For each Business Support Software component listed in the log file, run swremove. For more information1.4.2. Removing WEBES from an HP-UX Managed SystemBefore removing the software, back
24、up any files that you want to keep (i.e. repository,log files, configuration files, certificate files, etc.). If they are removed or overwritten during the re-installation, you can restore them.To remove the HP WBEM Services software, run the HP-UX swremove command.# swremove WBEMServicesIf the swre
25、move failed or unsuccess.pls Run the interactive webes_install_update utility webesclean_hpux_itanium_v51_bl1.sh, webesclean_hpux_parisc_v51_bl1.sh choose the option to remove all of WEBES, and follow any prompts that appear.The Clean-up utility can be used in the following instances:1. When the WEB
26、ES installation is aborted due to some reason such as system crash or incomplete installation. 2. When the WEBES installation is corrupted or the uninstallation is not successful. 3. When the ISEE installation is aborted or corrupted, or the uninstallation is not successful, for reasons related to t
27、he WCCProxy component. 4. When you want to install a fresh copy of WEBES or ISEE and you have observed problems that could be caused by prior installation or uninstallation failures1.4.3. Removing the B.05.05 Advanced Configuration Collector (ACC) Software PackageRemove the B.05.05 ACC software pack
28、age before installing the A.05.10 version. To remove the package,run the following command on each HP-UX managed system:swremove RS-ACC1.5. Installation Order · HP Diagnostics Software· QPKBASE· OpenSSL software· WBEM subscription· Requirements for SysFaultMgmt· SysFaul
29、tMgmt Software · Registration and Setup in HP SIM· Optional: o Advanced Configuration Collector Depot1.5.1. Software minimum requirements for the installation of RSP11.1111.2311.31Software minimum requirements for the installation of RSP are: HP UX 11.11 (part of the December 2006 re
30、lease)· any HP-UX 11i v1 OE is supported, if patch bundle BUNDLE11i patch bundle B.11.11.0306 (June, 2003) is installed · WBEMSvcs A.02.05 HP WBEM Services for HP-UX (December, 2006) or later · SysFaultMgmt A.04.00.04 HPUX 11.11 System Fault Management (December, 2006) or later ·
31、 OnlineDiag B.5 HPUX 11.11 Support Tools Bundle, (December, 2006) or later · OpenSSL A.00.09.07i.012 Secure Network Communications Protocol (December, 2006) or later · Optional: SysMgmtWeb A.2.2.5 HP-UX Web Based System Management User Interfaces or later* * Needed fo
32、r Proactive Services (Advanced Configuration Collections) Be aware that a problem with the current version of the SFM exist and that the fixed version will not be available prior to end of April!Software minimum requirements for the installation of RSP are: HPUX 11.23 (part of the
33、 December 2007 release)· September 2004 HP-UX 11iv2 Operating Environment (OEUR) minimum release or May 2005 11i v2 OE (required for vPars enablement) · PHKL_36288 - 11.23 Cumulative diag2 driver and vPars enablement (use in place of PHKL_32653) (reboot required after install) · PHKL_
34、34795 - 11.23 Cumulative IPMI driver patch (reboot required after install) · PHSS_37552 1.0 Aries cumulative patch · PHSS_37947 1.0 linker +fdp cumulative patch · PHSS_35055 - aC+ Runtime (IA: A.06.10, PA: A.03.71) · PHSS_36345 - 11.23 Integrity Unwind LibraryThese patches are av
35、ailable as a bundle in the ITRC => find patches in patch set => select "RemoteSupportSolutions" · WBEM Services A.02.05.08 WBEM Services CORE Product, (December, 2007) or later · SysFaultMgmt B.05.00.05 HPUX System Fault Management, (December, 2007) or later · On
36、lineDiag B.5 HPUX 11.23 Support Tools Bundle, (December, 2007) or later · OpenSSL A.00.09.07i.012 Secure Network Communications Protocol, (December, 2007) or later · Optional: SysMgmtWeb A.2.2.7 HP-UX Web Based System Management User Interfaces, (December, 2007) or later* *
37、 Needed for Proactive Services (Advanced Configuration Collections)While not required for HP-UX 11i v2, it is strongly recommended to use QPKBASE B.11.23.0712.070 Base Quality Pack Bundle for HP-UX 11i v2 (December 2007), but it is not a compulsory requirement for remote monitoring. Skript to check
38、the prerequisits (by Christian Schwartz)!Software minimum requirements for the installation of RSP are: HPUX 11.31 · WBEM Services Version A.02.05 or later · · SysMgmtBase B.00.02.03 or later · SysFault Mgmt C.01.00.29.yy HPUX System Fault Management or later · Online
39、Diagnostics B.11.31.01.yy or later · OpenSSL Version A.00.09.07e.013 or later · Optional: SysMgmtWeb version A.2.2.4 (HP-UX Web Based System Management User Interface) or later* * Needed for Proactive Services (Advanced Configuration Collections) System Fault Manager (SFM) for 1
40、1.31 is on the OE Media and Software Depot (latest version only).1.6 Installation of Diagnostics and Support Tools SoftwareThe HP diagnostics software (support tools) is automatically installed when you install the operating system. You only need to check if the required version is installed.#swlist
41、 -l product |grep Sup-Tool-MgrYou can obtain the diagnostics software either from the Support-Plus-Media CD or from the HP Software Depot page. The minimum version depends on the SysFaultMgmt version and the OS. You definitely need to update if your diagnostic version is not at least:HP-UX 11i v1 De
42、c. 2006 OnlineDiag B.5HP-UX 11i v2 1. Update the software (OnlineDiag_<hpux-version>) if needed:§ swinstall s <depot_location>/<diag_software_depot_name> 2. Check the software distributor logs for errors after installing HP diagnostics. If necessary, take corrective
43、action.3. Some Diagnostic Version need additional patches, info about the version specific patched can be found here. Note: If you want to install this on a virtual partition system, all vpar need to have the software installed. If your system is a Virtual Machine only the host needs to have the sof
44、tware installed. 1.7 Installation of OpenSSL softwareInstalling OpenSSLTo install OpenSSL, complete the following steps:1. Log in as superuser.2. Insert the software CD into the appropriate drive if you are installing from the Application Release CD. If you are downloading the software package from
45、the Software Depot, download the depot and follow the instructions provided in the installation page for OpenSSL.3. Enter the following command to install OpenSSL:$ swinstall -s <fully-qualified depot source path> OpenSSLThe swinstall command installs the OpenSSL software in the /opt/openssl d
46、irectory. It places the sample codes in the /opt/openssl/src directory.Note:HP-UX 11i v1 customers must install the GOLDQPK11i QPK that is delivered on the Support Plus media. No patches are required for installing OpenSSL on HP-UX 11i v2and HP-UX 11i v3.As updates to OpenSSL become available and in
47、stalled over time, the HP WBEM Services cimserver process must be shutdown and restarted in order to run against any new version of OpenSSL. For more information on shutting down and restarting the cimserver, see the HP WBEM Services System Administrators Guide.1.8 Installation WBEMServicesYou need
48、to log in to the system as root (uid=0) to install the HP WBEM Services software. Software is available in Software Depot (SD) format as a single SD depot.To install the software, download the product from .Copy the downloaded depot file to a local directory on your system, then run the HP-UX swinst
49、all command and follow the instructions to install the software from the depot. The filesets that make up the HP WBEM Services product are: WBEM-CORE, A.02.07.xx - WBEM Services core fileset for hp Integrity servers WBEM-CORE-COM, A.02.07.xx - WBEM Services core fileset for hp Integrity servers and
50、hp 9000 servers WBEM-MAN, A.02.07.xx - WBEM Services man pages WBEM-MX, A.02.07.xx - Reserved for future useTo verify that the software is installed correctly, enter the HP-UX swverify command at the end of the install (a Verification succeeded message from swverify indicates that the software has b
51、een installed correctly): swverify WBEMSvcsTo see if the CIM Server is running, issue the following command to check for the cimserver process: ps -ef | grep cimserver. You should see three processes: cimserver, cimservera, and cimserverd (cimserverd is a daemon process that monitors cimserver to en
52、sure it remains available).1.9 Checking Requirements for SysFaultMgmt1.9.1.o HP-UX 11i v1 September 2005 or later o GOLDBASE11i - B.11.11.0612.459 Base Patches for HP-UX 11i v1, December 2006o SysMgmtWeb version A.2.2.5 (HP-UX Web Based System Management User Interface) o OpenSSL A.00.09.07e.012 or
53、later o WBEMServices A.02.05 WBEM Services CORE Product o OnlineDiag B.11.11.18.xx 1.9.2.o May 2005 HP-UX 11iv2 Operating Environment (OEUR) or later o QPKBASE B.11.23.0712.070a Base Quality Pack Bundle for HP-UX 11i v2, December 2007 o OpenSSL A.00.09.07e.013 or later o SysMgmtWeb version A.2.2.7 (
54、HP-UX Web-Based System Management User Interface) o PHKL_34795 IPMI patch (Dependency: PHKL_31500)o WBEMServices A.02.05.08 WBEM Services CORE Product o1.9.3.o May 2005 HP-UX 11iv2 Operating Environment (OEUR) or latero QPKBASE B.11.23.0803.xxx Base Quality Pack Bundle for HP-UX 11i v2, March 2008 o
55、 OpenSSL A.00.09.07e.013 or later o SysMgmtWeb version A.2.2.7 (HP-UX Web-Based System Management User Interface) o WBEMServices A.02.05.08 WBEM Services CORE Product o OnlineDiag version B.11.23.10.xx o PHKL_34795 IPMI patch (Dependency: PHKL_31500)1.9.4. o HP-UX 11i v3 February 2007 o OpenSSL Vers
56、ion A.00.09.07e.013 or later o Baseboard Management Controller (BMC) firmware version 70.59 or later o WBEM Services Version A.02.07 or later o EVM-EventMgr B.11.31 o SysMgmtBase B.00.02.03 o SysMgmtWeb version A.2.2.4 (HP-UX Web Based System Management User Interface) o1.10 Installation SysFaultMgm
57、t SoftwareThe SysFaultMgmt Software is located at different location. It can be downloaded from or as internal depot bundled with all providers and additional Software useful for RSP or it can be installed as part of the HPUX OE Media. For HPUX 11.23 patch PHKL_34795 is a prerequisite install this patch prior to installing SFM.
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 場地安防合同范本
- 醫(yī)療機(jī)構(gòu)設(shè)備更新項目概述
- 淺談油田開發(fā)項目環(huán)境影響評價工程分析的編制
- 中國印泥行業(yè)發(fā)展趨勢預(yù)測及投資戰(zhàn)略咨詢報告
- 房產(chǎn)測繪成果報告(示范文本)
- 2025年廢棄資源和廢舊材料回收加工品項目發(fā)展計劃
- 變配電擴(kuò)容工程進(jìn)度計劃
- 17MWh儲能電站項目投資估算與融資方案
- 新型墻體材料項目可行性研究報告-備案立項
- 七年級下冊語文人教版知識點(diǎn)
- 射頻消融術(shù)介紹【共48張PPT】
- 驗證機(jī)械能守恒物理實驗報告
- 5.13 導(dǎo)游口頭語言表達(dá)技巧《導(dǎo)游業(yè)務(wù)》教學(xué)課件
- 人教版小學(xué)信息技術(shù)教材-課件
- 30萬室內(nèi)裝修預(yù)算表
- 拉線的制作詳細(xì)
- 律師報價函(訴訟)
- 新生兒沐浴評分標(biāo)準(zhǔn)
- 潛水作業(yè)指導(dǎo)書
- (完整版)設(shè)計管理
- 感謝對手閱讀附答案
評論
0/150
提交評論