1、Y Series Hydraulic dynamometer Manual Shanghai LINYAO Power Test Equipment Co., Ltd. 2011-10Foreword Y series hydraulic dynamometers are used electric drain valve control. That is, by changing the valve opening to change the size of the absorbed power. Braking power range from 20KW to 5900KW, full r
2、ange of domestic and foreign users according to their range of engine power to choose the right model to buy.The product is mainly used to detect a variety of diesel, gasoline, motor and other power machine of effective power. Is a power machine characteristics test, test the efficiency of transmiss
3、ion machinery essential test equipment.The basic product is a one-way test, user test for both two-way ordering, please request, our company has given special customization. Technical Specifications1. Features Small size, easy to install; Simple structure, convenient operation and maintenance; braki
4、ng torque; high accuracy; stable and reliable; magnetic-electric speed sensor for high accuracy measurement of the instantaneous speed; electric control valve fast load control;Performance MeasurementProject types range sensor accuracy RemarksSpeed ZSB magnetoelectric speed sensor 300-7500r/min
5、7; 1r/min than 7500r/minWhen the wheel speed and control of the separate components outside the grounds.Torque strain gauge pressure sensor and pull the dynamometer scale matching ± 0.2% FSPrecision potentiometer valve position(DPF, YZ60 water gate actuator) 0-100% 0.2% F.SPrecision potentiomet
6、er throttle position(YZ60, YZ60A throttle actuator) 0-100% 0.2% F.S3. Technical parametersModelY1500The maximum absorption rate of the public (KW)1500Torque measurement accuracy (F.S)±0.4%Speed accuracy (F.S)±0.1 Spindle rotationUnidirectionalBraking force measurement range (N)012000The ma
7、ximum braking torque (N.m)11760Maximum water consumption (Kg / h)30000Drainage maximum temperature ()70The total length of the spindle1296Part of a long and taper spindle taper192,1:30Spindle center to the underside of the base under high760Dynamometer Dimensions (L × W × H)1598×1310&
8、#215;1135Base Size (L × W × H)1476×1200×260Foot screw position1350×1074Dynamometer Weight (Kg)2800Maximum spindle speed (r / min)3000Moment of inertia (Kg.M2)3.6The Unit:mmDynamometer structureY-type hydraulic dynamometer mainly by body parts, body parts measured force, into
9、 the drainage components, calibration components, electric drain valve parts, auto-adjusting device composed of parts and lubricating parts. See Figure II (a), (b). 1. Body parts Body parts is to use the dynamometer to absorb water, the main components of the effective torque power machine. Figure t
10、hree (a), (b). Power machine output mechanical energy into heat in here, by the absorption of water into the shell in the discharge away, a very small part by the dynamometer casing wall heat to the air. Its simple structure from the one in the rolling bearing can swing on a rack in the shell and co
11、mposed of the rotor on the spindle. Dynamometer rotor mounted on the spindle center, left and right side of the bearing shell and the shell were symmetrical around the rotor mounted on both sides, left and right side of the rotor shell pits and pit forming the working chamber. Shell around the beari
12、ng housing connected with bi-metal sleeve bushing play a role in both, also played a role in sealing water. Y1500, Y2500, Y3300, Y5900-type dynamometer in order to prevent water leakage from the gap sealed to prevent water from entering the bearing to ensure that the bearing life. Shell has opened a
13、 drainage hole, so the bearing shell has opened a water hole, in order to ensure the entry of cold water and hot water discharge. Around the bearing housing has a overflow pipes, dump the water cycle through the overflow pipes of water thrown into the base after discharge. Installed at both ends of
14、the spindle taper coupling, speed gear with one side, through the speed sensor, spindle speed can be displayed in the digital display table.1, the body part2, part 3 dynamometer, lubricated parts 4, into the drainage unit5, calibration parts6, the automatic adjustment device components1, the base 2,
15、 bearing 3, the coupling 4, the spindle assembly 5, the bearing shell 6, shell 7, the side shell 8, the rotor 9, the speed sensor 10, speed gearDynamometer body parts Institutional component force measurement system for the determination of power, see figure IV (a), (b). Mainly by the brake arm, pul
16、l the pressure sensor and the live bolt and other components. Body parts of the braking torque generated by the brake arm and pull the anti-torque equilibrium pressure sensor, the electronic digital display instrument displays braking force size. Course of their work to protect the sensor, at the en
17、d of the live bolt installation of a nylon ring or rubber ring, a cushion, while the transport in order to prevent damage after by the vibration sensor, with support for fixed protection devices, in use to be loose on fixed sensor bolts, pull to the side of the activities of the board, as long as no
18、 active plate to bolt to spin. 1, the brake arm 2, mounting bolts 3, live bolt 4, pull the pressure sensorCorrection component (statics parts)Correction component dynamometer is used as the school's use of staticIt is mainly from the calibration arm, hanging hook parts, boom, pallets and weight
19、and so on.Dynamometer spindle center to statics arm triangle edge weight from the total weight of the L value and W below.L及W值 ModelArm length L (mm)Weight total weight W (kg)Y15001947.5±0.30500 Correction component diagram1, calibration arm2, parts hanging hook 3, the boom4, tray 5, the weight
20、 Works and power calculations1、 Works Power generator driven by the dynamometer coupling on the rotor shaft synchronized rotating components, stirred the working chamber in the water. As the centrifugal force generated by the rotor and the rotor rotating the role of pits, water pits in the side of t
21、he shell and the rotor between the strong water vortex, it is a rotational torque to the shell, so that the torque power machine passed by the rotor casing, mounted on the shell shell on the brake arm will rotate with an angle, which will force the system to pass and pull the brake arm connected to
22、the pressure sensor, the electronic digital display device the size of the braking force.Dynamometer through the electric drain valve control valve opening, or through the automatic adjustment device controlled drainage actuator, control valve actuator by the drainage of the opening, to change the d
23、ynamometer working chamber pressure to change the absorption of water power size. At the same time the speed of the dynamometer measured by the speed sensor, the electronic display on the instrument display.Because it is pressure-controlled hydraulic dynamometer, but also by changing the valve openi
24、ng pressure to adjust the working chamber, the whole process must be automatic closed-loop control system, so the pressure Y-type dynamometer must be equipped with automatic control of power control cabinet to run the job.2、 Calculate P= F n/ 9549 (kw)F- Torque Nm n- Speed r/min Water supply system1
25、 dynamometer cycle of water supply systems of water supply available. The use of high or low voltage supply regulator tank plus pipe pump pressurized water tank. General North is the use of low-voltage indoor water tank water tank in the form of additional pipeline pump (see figure VIII).2 dynamomet
26、er at the water inlet pressure can be greater than or equal 0.05MPa, generally 0.05 0.15MPa, when the dynamometer at full water line work, required water pressure higher; below the waterline work full time, pressure can be lower. Water pressure should remain stable, the pressure fluctuations in the
27、range of ± 5KPa. Dynamometer work, the water pressure will directly affect the dynamometer pit side shell and rotor cavitation of the working chamber.3 dynamometer work process, the water can not be stopped. Into the water about 20 liters per kilowatt-hour or so, drain the temperature can not e
28、xceed 70 , general economic drain temperature between 55 60 .4-cycle cooling water system consists of reservoirs, pumps, tank regulator, drainage into the connecting pipe, pressure gauge, valves and other components. Pool volume should be considered and measured maximum cooling power of water consum
29、ption, and a certain amount of surplus water during the cycle to compensate for the dissipation, in the conditions permit, the proposed pool as possible to increase the volume. Volume of tank water consumption should be considered when the maximum voltage supply (water consumption technical paramete
30、rs see table). Water than the pump's maximum power dynamometer water consumption, the regulator for the water tank volume can be recommended about 2 5 M3, a small amount of water less desirable value, the desirability of greater water consumption. Pool volume is generally about five times the ta
31、nk volume. Able to do so, as far as possible larger.5 into, drain diameter should fit into the outlet diameter dynamometer requirements 6 Way inlet valve should be connected in series one and a pressure gauge. Valve for regulating the water pressure, for a fixed engine type, once it is set after the
32、 general no longer move, so the valve can be mounted in any convenient location, and the dynamometer on the inlet valve is used to open and close the water supply. 7 Drain line and generally larger than the inlet pipe diameter. Clay pipe leading to the pool drain can be used to make the
33、loop. If the user can be discharged into the sewer water rich. Drain line should pay attention to two issues, namely, drainage overflow pipes can not be compared with the collusion, the pressure is too high to prevent the drainage overflow pipes back to the irrigation; second drain if not smooth, it
34、 will cause excessive back pressure, the impact normal dynamometer test. Therefore, piping arrangements should be as short as possible and bend less. 8 Circulating water through the device after cleaning water as the dynamometer, the dynamometer will be reduced in scale formation. If there is no wat
35、er treatment equipment, allowing use tap water or clean water, but there is mixed with sand and other impurities. Not to use seawater. According to different regions of the PH value of water is not too high, consider whether you need to install cleaning devices. Dynamometer calibration Dynamometer b
36、ased on static correction. Statics general design for the arm 1947.5mm. The weight placed on the 10 kg weight plate, the corresponding display 200 Newton; 20 kg display 400 Newton. . . . . . .Due to structural reasons, such as arm length zoom in or out a certain multiple of the value, the display sh
37、ould also be enlarged or reduced as appropriate multiples. Correction steps: 1, correction level of the dynamometer. Dynamometer installed base in two mutually perpendicular horizontal level degree 1 / 1000.2, the coupling with the engine dynamometer separate, remove the weights, and put on correct
38、arm, hanging weight plate. Newly installed dynamometer should be noted that the sensor protection device on the loose bolts, pull to the side of the activities of the board.3, connected to the power cabinet, 1 minute warm.4, the load table shows zero, zero through the instrument.5, increase in weigh
39、t plate standard weight, the weight of full-scale one-time added about 80%, and adjust the instrument so that the load weight increases the displayed value with the corresponding weight. Remove the added weight, load the table should be back to zero.6, add or subtract load test sequence (gradually a
40、dded to the full scale, then in turn load shedding to zero), the weight values point by point with the digital value corresponding to a linear relationship, repeatedly adjusted until the required accuracy. Otherwise, you should find out the ultra-poor reasons. Ruled out, then repeat the above operat
41、ion. When the test range is small, in order to achieve high calibration accuracy can be corrected only in this range.7, the correction is completed, open the correct arm, re-fitted with weights, and the coupling with the engine dynamometer connected well.New dynamometer installed, usually in need of
42、 correction, the long-term set aside by the dynamometer, the dynamometer using about half a year or in use when an abnormality is detected, are required to be linked to the dynamometer's weight static correction. The use of dynamometer 1, before starting(1) Turn on the instrument(2) Check the co
43、upling and shaft coupling situation.(3) Check the power machine and dynamometer concentricity.(4) Check into the effluent pipe connection system and circulation.(5) cleaned surface, the lubricating oil filling point, and turn the spindle, check whether the rotor and other parts of the collision and
44、rotation is not flexible and so on.(6) correction to meet the requirements.(7) drain valve fully open (minimum load position).2, boot test(1) start the power generator driven by the dynamometer to the same spindle rotation speed, until the power machine in normal operation, you can test.(2) all ente
45、red the water valve to regulate the size of the drainage valve opening, until the working conditions with the power machine is consistent.(3) external characteristics of the engine is doing, speed characteristics, load characteristics and other characteristics of the test, choose and dynamometer con
46、trol cabinet matching the constant position, constant torque, constant speed four control methods.(4) For some engines, sometimes in a fixed dynamometer under the pressure of the water supply can not meet all the requirements of the operating point of the test, which can be appropriate in different
47、experimental conditions regulating water supply pressure.3, end of the trial(1) close the inlet valve.(2) drain valve fully open.(3) the engine is running at low speed after a few minutes downtime.(4) rotation sensor protection device, so that the stator showing lock status sensor from power.(5) con
48、nected to the power cut off and the cabinet.(6) stop the oil lubrication system.(7) If a long time do not do testing, dynamometer need to open the bottom drain valve, put to the water,Water use in order to prevent the bearing, be sure to remember! ! ! "First boot, after the turn on the water; f
49、irst off the water, then stop" principle. Dynamometer in the rotation to ensure that state water, but should prevent dynamometer continuous operation in the anhydrous state for too long and burn sealing components, (requiring anhydrous state at time of less than 2 minutes).Dynamometer maintenan
50、ce and repair1, the installation and use should be sent to the person responsible for the use of personnel must fully understand the use of the dynamometer.2, the dynamometer to the factory to make a comprehensive inspection. From the date of manufacture when used as a long, action must be part of the inspection and maintenance.3, the power machine and hydraulic dynamometer can not be a collision.4, in the testing process, such as a strong vibration, should immediately stop the test, check the reason, troubleshooting, to ensure smooth operation of t
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年氣體分離及液化設(shè)備項(xiàng)目申請(qǐng)報(bào)告模板
- 2025年壓縮式垃圾車(chē)項(xiàng)目提案報(bào)告范文
- 企業(yè)員工辭職信范文(15篇)
- 2024年未實(shí)繳出資股權(quán)投資退出與轉(zhuǎn)讓服務(wù)合同3篇
- 2025年抗蛇毒血清項(xiàng)目提案報(bào)告模范
- 2025年柔性樹(shù)脂版項(xiàng)目申請(qǐng)報(bào)告模式
- 教師綜合培訓(xùn)的心得體會(huì)5篇
- 我的大學(xué)生活演講稿
- 我的未來(lái)不是夢(mèng)演講稿(15篇)
- 學(xué)校學(xué)生實(shí)習(xí)自我鑒定(集合5篇)
- 浙江大學(xué)2011–2012學(xué)年冬季學(xué)期《高級(jí)數(shù)據(jù)結(jié)構(gòu)與算法分析》課程期末考試試卷
- MOOC 信號(hào)與系統(tǒng)-西北工業(yè)大學(xué) 中國(guó)大學(xué)慕課答案
- 手術(shù)保護(hù)性約束
- 砌磚工程實(shí)訓(xùn)總結(jié)報(bào)告
- 低空經(jīng)濟(jì)研究報(bào)告-中國(guó)低空經(jīng)濟(jì)行業(yè)市場(chǎng)現(xiàn)狀調(diào)查及未來(lái)發(fā)展趨勢(shì)報(bào)告(2020-2023年)
- 酒水服務(wù)與品鑒智慧樹(shù)知到期末考試答案2024年
- 2024法務(wù)部門(mén)合規(guī)風(fēng)險(xiǎn)管理實(shí)踐模板
- 商場(chǎng)保潔服務(wù)日常巡檢方案
- 中醫(yī)培訓(xùn)課件:《艾灸技術(shù)》
- 學(xué)??蒲刑幪庨L(zhǎng)述職報(bào)告范文
- 國(guó)家開(kāi)放大學(xué)《理工英語(yǔ)4》綜合練習(xí)參考答案
評(píng)論
0/150
提交評(píng)論