#/28鋪設(shè)水泥管道的管底墊層砂漿標號,應(yīng)符合設(shè)計要求,其砂漿的飽滿程度不應(yīng)低于95%,不得出現(xiàn)凹心,不得用石塊等物墊管塊的邊、角。管塊應(yīng)平實鋪臥在水泥砂漿墊層上。兩行管塊問的豎縫充填的水泥砂漿,其標號應(yīng)符合設(shè)計的規(guī)定,充填的飽滿程度不應(yīng)低于75%。管頂縫、管邊縫、管底八字應(yīng)抹1:2.5水泥砂漿;嚴禁使用鋪管或充填管問縫的水泥砂漿進行抹堵,應(yīng)粘結(jié)牢固、平整光滑、不空鼓、無欠茬、不斷裂。抹頂縫、邊縫及管底八字<圖7.4.5>。水泥管塊的接續(xù)方法宜采用抹漿法,采用抹漿法接續(xù)管塊,其所襯墊的紗布不應(yīng)露在砂漿以外,水泥砂漿與管身粘結(jié)牢固,質(zhì)地堅實、表面光滑、不空鼓、元飛刺、無欠茬、不斷裂,并應(yīng)符合下列規(guī)定:1兩管塊接縫處應(yīng)用紗布包80mm寬,允許±l0mm的誤差,長為管塊周長加80?120mm,均勻地包在管塊接縫上。2接縫紗布包好后,應(yīng)先在紗布上刷清水,水要刷到管塊飽和為度,再刷純水泥漿。3接縫紗布刷完水泥漿后,應(yīng)立即抹1:2.5的水泥砂漿。4紗布上抹的1:2.5水泥砂漿厚度應(yīng)為12?15mm,其下寬應(yīng)為100mm,上寬應(yīng)為80mm,允許正偏差不大于5mm。各種管道引入人<手>孔、通道的位置尺寸應(yīng)符合設(shè)計規(guī)定,其管頂距人<手>孔上覆,通道蓋板底不應(yīng)小于300mm,管底距人<手>孔,通道基礎(chǔ)頂面不應(yīng)小于400mm。引上管引入人<手>孔及通道時,應(yīng)在管道引入窗口以外的墻壁上,不得與管道疊置。引上管進入人<手>孔、通道,宜在上覆、蓋板下200?400mm范圍以內(nèi)。彎管道的曲率半徑應(yīng)符合設(shè)計要求,不宜小于36m。其水平或縱向彎管道各折點坐標或標高,均應(yīng)符合設(shè)計要求。彎管道應(yīng)成圓弧狀。塑料管道鋪設(shè)塑料管道的鋪設(shè)應(yīng)滿足設(shè)計規(guī)定的各項要求,設(shè)計文件中無明確規(guī)定的內(nèi)容,應(yīng)符合本節(jié)的相關(guān)規(guī)定。塑料管鋪管及接續(xù)時,施工環(huán)境溫度不宜低于-5℃。塑料管道的組群應(yīng)符合下列規(guī)定:1管群應(yīng)組成矩形,橫向排列的管孔數(shù)宜為偶數(shù),且宜與人<手>孑L托板容納電纜數(shù)量相配合。2矩形高度不宜小于寬度,但不宜超過一倍。3管孔內(nèi)徑大的管材應(yīng)放在管群的下邊和外側(cè),管孔內(nèi)徑小的管材應(yīng)放在管群的上邊和內(nèi)側(cè)。4多個多孔管組成管群時,宜選用柵格管、蜂窩管或梅花管,同一管群宜選用一種管型的多孔管,但可與波紋單孔管或水泥管等大孔徑管組合在一起。5多個多孔管組群時,管間宜留10?20mm空隙,進入人孔時多孔管之間應(yīng)留50mm空隙,單孔波紋管、實壁管之間宜留20mm空隙,所有空隙應(yīng)分層填實。6兩個相鄰人孔之間的管位應(yīng)一致,且管群斷面應(yīng)符合設(shè)計要求。管材材質(zhì)的選擇應(yīng)符合下列規(guī)定:1管材的規(guī)格和材質(zhì)應(yīng)符合國家現(xiàn)行標準和設(shè)計要求。2正常的溫度環(huán)境宜選用聚氯乙烯<PVC—U>塑料管,高寒環(huán)境宜選用高密度聚乙烯<HDPE>塑料管。3在鼠害、白蟻地區(qū),宜選用具有相應(yīng)防護能力的塑料管。4采用定向鉆孔方式鋪設(shè)管道時,宜采用高密度聚乙烯<HDPE>管。5非埋地應(yīng)用的塑料管,應(yīng)采取防老化和防機械損傷等保護措施。管道鋪設(shè)應(yīng)符合下列規(guī)定:1通信塑料管道與鐵道的交越角不宜小于60°。交越處距道岔、回歸線的距離應(yīng)大于3m;與有鐵道交越處,當采用鋼管時,應(yīng)有安全設(shè)施。2通信塑料管道的埋設(shè)深度〈管頂至路面》,在人行道下不應(yīng)小于0.1m,在車行道下不應(yīng)小于0.8m;與軌道交越〈管頂?shù)杰壍赖祝静粦?yīng)小于1.0m;與鐵道交越〈管頂至軌道底>不應(yīng)小于1.5m.埋深達不到要求時,應(yīng)加保護措施。3管道進入人孔處,管道頂部距人孔內(nèi)上覆頂面的凈距不得小于300mm,管道底部距人孔底板的凈距不得小于400mm。引上管進人人孔處宜在上覆頂下面200?400mm范圍內(nèi),并與管道進入的位置錯開。4通信塑料管道宜設(shè)在凍土層下,在地基或基礎(chǔ)上面均應(yīng)設(shè)50mm墊層,墊層應(yīng)用細砂或細土。在嚴寒且水位較低的地區(qū)鋪設(shè)在凍土層內(nèi)時,宜在塑料管群周圍填充粗砂,且圍護厚度不宜小于200mm。5通信塑料管道的段長應(yīng)按相鄰兩個人孔的中心點間距而定。直線管道的段長不應(yīng)大于200m,高等級公路上的直線管道段長不應(yīng)大于250m;彎曲管道的段長不應(yīng)大于150m。6彎曲管道的曲率半徑不應(yīng)小于10m,彎管道的轉(zhuǎn)向角度應(yīng)盡量小,同一段管道不應(yīng)有反向彎曲〈即"S'‘形彎,或彎曲部分的轉(zhuǎn)向角度>90。的彎管道<即"U"形彎,。彎曲管道示意見圖7.5.5-1。7在特殊情況下,當HW500mm時,為局部躲避障礙物,可允許按照圖7.5.5-2進行施工。圖7.5.5-2彎曲管道包封及鋪設(shè)不意<HW500mm>彎曲管道的接頭應(yīng)盡量安排在直線段內(nèi),如無法避免時,應(yīng)將彎曲部分的接頭作局部包封,包封長度不宜小于500mm,也可將彎曲部分的管道進行全包封。包封的厚度宜為80?100mm〈圖7.5.2-2>。嚴禁將塑料管加熱彎曲。?8管道進入人<手,孔時,管N不應(yīng)凸出人<手>孔內(nèi)壁,應(yīng)終止在距墻體內(nèi)側(cè)100mm處,并應(yīng)嚴密封堵,管Et做成喇叭口。管道基礎(chǔ)進入人<手,孔時,在墻體上的搭接長度不應(yīng)小于140mm。9塑料管應(yīng)由人工傳遞放入溝內(nèi),嚴禁翻滾入溝或用繩索穿入孔內(nèi)吊放。塑料管的連接應(yīng)符合下列規(guī)定:1塑料管的連接宜采用承插式粘接、承插彈性密封圈連接和機械壓緊管體連接;承插式管接頭的長度不應(yīng)小于200mm2塑料管材標志面應(yīng)朝上方。3多孔塑料管的承插1:I的內(nèi)外壁應(yīng)均勻涂刷專用中性膠合粘劑,最小粘度為500MPa?s,塑料管應(yīng)插到底,擠壓固定。4各塑料管的接口宜錯開排列,相鄰兩管的接頭之間錯開距離不宜小于300mm;彎曲管道彎曲部分的管接頭應(yīng)采取加固措施。5柵格管、波紋管、硅芯管組成管群應(yīng)間隔3m左右用勒帶綁扎一次,蜂窩管或梅花管宜用支架分層排列整齊。塑料管群小于兩層時,整體綁扎;大于兩層時,相鄰兩層為一組綁扎,然后整體綁扎。6塑料管的切割應(yīng)根據(jù)管徑大小選用不同規(guī)格的裁管刀,管口斷面應(yīng)垂直管中心,平直、無毛刺。7單孔波紋塑料管的接續(xù)宜選用承插彈性密封圈連接。進行接續(xù)作業(yè)時,先檢查密封圈是否完好,并將承插的內(nèi)、外口清理干凈,不得殘留淤泥雜物,然后將密封圈放置在承插1:1的中間一個波紋槽內(nèi),方向不應(yīng)放反,在承口內(nèi)涂少量肥皂水,將插口端對準承口插入,直至牢固為止。將B管插口插入A管承口的示意圖。鋼管鋪設(shè)鋼管通信管道的鋪設(shè)方法、斷面組合等均應(yīng)符合設(shè)計規(guī)定;鋼管接續(xù)宜采用套管焊接,并應(yīng)符合下列規(guī)定:1兩根鋼管應(yīng)分別旋入套管長度的1/3以上。兩端管口應(yīng)銼成坡邊。2使用有縫管時,應(yīng)將管縫置于上方。3鋼管在接續(xù)前,應(yīng)將管口磨圓或銼成坡邊,保證光滑無棱、無飛刺。7。6.2各種引上鋼管引入人<手>孔、通道時,管口不應(yīng)凸出墻面,應(yīng)終止在墻體內(nèi)30?50mm處,并應(yīng)封堵嚴密、抹出喇叭口。8工程驗收隨工驗收管道器材隨工檢驗應(yīng)包括下列內(nèi)容:I水泥管塊、塑料管材及規(guī)格型號和其他材料等。2塑料管接頭與管材應(yīng)配合緊密。3塑料管接頭膠水最小粘度應(yīng)符合規(guī)定。4多孔塑料管捆綁扎帶、管道支架應(yīng)符合質(zhì)量要求。5混凝土、磚、鋼筋、ATL口圈和蓋、支架和托板、拉力環(huán)等均應(yīng)符合標準。對管道地基的隨工檢驗應(yīng)包括下列內(nèi)容:I溝底夯實、平整。2管道溝及人<手>孔中心線。3地基高程、坡度。8?1.3對管道基礎(chǔ)的隨工檢驗應(yīng)包括下列內(nèi)容:I基礎(chǔ)位置、高程、規(guī)格。2基礎(chǔ)混凝土標號及質(zhì)量。3設(shè)計特殊規(guī)定的處理、進入孔段加筋處理。4障礙物處理情況。鋪設(shè)管道的隨工檢驗應(yīng)包括下列內(nèi)容:I管道位置、斷面組合、高程。2冰凍層處理,塑料管周圍填充的粗砂。3淺埋塑料管應(yīng)采取設(shè)計規(guī)定的保護措施。4回填土應(yīng)保證質(zhì)量和分層夯實,不得有雜物回填。5填管問縫及管底墊層質(zhì)量。6,埋設(shè)警告帶、鋪混凝土板、普通燒結(jié)磚、蒸壓灰砂磚或蒸壓粉煤灰砂磚。7抹頂縫、邊縫、管底八字質(zhì)量。8管道與相鄰管線或障礙物的最小凈距應(yīng)符合設(shè)計規(guī)范的規(guī)定。9檢查管道與鐵道、有軌電車道的交越角,交越處距道岔、回歸線的距離。10檢查管道過橋、溝、渠、河、坎、路、軌等特殊地段。對管道接續(xù)的隨工檢驗應(yīng)包括下列內(nèi)容:1管口應(yīng)平滑清潔。2膠水應(yīng)涂刷均勻,管子與管接頭應(yīng)連接牢靠。3管道接續(xù)質(zhì)量<應(yīng)逐個檢查>。4多層多孔管鋪設(shè)其管子接口宜錯開。5柵格管、波紋管或硅芯管組成管群應(yīng)按規(guī)定間隔。采用勒帶捆綁一次。蜂窩管或梅花管宜用支架排列整齊。6不同人孔之間的管位應(yīng)一致且管群斷面應(yīng)符合設(shè)計要求。人<手>孔通道掩埋部分的隨工檢驗應(yīng)包括下列內(nèi)容:1砌體質(zhì)量及墻面處理質(zhì)量。2混凝土澆灌質(zhì)量<含基礎(chǔ)、上覆等>。3管道入口內(nèi)外側(cè)填充情況、質(zhì)量。4人<手>孔建筑應(yīng)符合設(shè)計規(guī)定要求。5應(yīng)按人<手>孔周圍的土質(zhì)情況做相應(yīng)的地基和基礎(chǔ)。6塑料管材標志面應(yīng)朝上。對防水、防有害氣體的隨工檢驗應(yīng)包括下列內(nèi)容:1管道進入建筑物應(yīng)采取防水、防可燃氣體進入等措施。2管道進入建筑物或人<手>孔時,應(yīng)做鋼筋混凝土基礎(chǔ)和混凝土包封。3管道進入建筑物或人<手>孑L時,應(yīng)加管堵頭,防止雜物進入管內(nèi)。4管道與燃氣管交越處,如燃氣管有接合裝置和附屬設(shè)備時,通信管道應(yīng)作包封2m。工程初驗工程初驗應(yīng)包括下列內(nèi)容:1核對竣工圖標注的管道走向、人<手>孔位置、標高<與路面標高的配合>、各段管道的斷面和段長,以及彎管道的具體位置和彎曲半徑要求。,,2檢查已簽證的隱蔽工程驗收項目,如發(fā)現(xiàn)異常,應(yīng)進行抽檢復驗。3管孔試通。4管孔封堵。5人<手>孔內(nèi)的各種裝置應(yīng)齊全、合格。管孔試通應(yīng)符合下列要求:1直線管道管孔試通,應(yīng)采用拉棒方式試通。拉棒的長度一般為900mm,拉棒的直徑為管孔BJ徑的95%。2彎管道管孔試通,彎管道的曲率半徑水泥管道不應(yīng)小于36m,塑料管道不應(yīng)小于lOre,管孔試通宜采用拉棒方式、也可采用塑料電纜方式。采用拉棒方式試通,拉棒的長度宜為900mm,拉棒的直徑為管孔內(nèi)徑的60%?65%;采用塑料電纜試通時,其拉棒的長度宜為900mm,拉棒的直徑應(yīng)為管孔內(nèi)徑的95X。3抽查規(guī)則,每個多孔管試通對角線2孔,單孔管全部試通。4各段管道全部試通合格,管道工程才能稱為合格。不合格的部分應(yīng)在工程驗收前找出原因,并得到妥善的解決。管孔封堵應(yīng)符合下列要求:1塑料管道進入建筑物的管孔應(yīng)安裝堵頭。2塑料管道進人人<手>孔的管孔應(yīng)安裝管堵頭。3管堵頭的拉脫力不應(yīng)小于8N。人<手>孔的規(guī)格和裝置應(yīng)符合下列要求:1人<手>孔的口圈、蓋子、積水罐支架和托板、拉力環(huán)等各種裝置的位置、規(guī)格、數(shù)量和質(zhì)量等應(yīng)符合標準設(shè)計。2人<手>孔的規(guī)格、形狀和尺寸應(yīng)符合工程設(shè)計。3管道進入人<手>孔的斷面布置應(yīng)與托架和托板的規(guī)格、數(shù)量相配合,每層管孔數(shù)與托板容納的電<光>纜數(shù)相一致。工程終驗工程終驗應(yīng)按下列要求:1對竣工文件的驗收:施工單位應(yīng)在工程終驗前,將工程竣工文件一式三份提交建設(shè)單位或監(jiān)理單位。2對竣工管理文件的驗收:竣工管理文件應(yīng)包括工程實施過程中,建設(shè)、設(shè)計、施工、監(jiān)理、材料供應(yīng)、政府主管相關(guān)部門及合作單位之間的往來文件、備忘錄等內(nèi)容,以及施工圖設(shè)計的審查紀要和批準文件。3竣工技術(shù)文件應(yīng)包括下列內(nèi)容:1>建筑安裝工程量列出明細表。2>工程說明包括:工程性質(zhì)和概述、設(shè)計階段、施工日期、重大變更、新技術(shù)新工藝、土質(zhì)狀況、地下水位、冰凍層、環(huán)境溫度等。3>竣工圖紙:施工中更改后的施工設(shè)計圖,應(yīng)標明管道的平面、剖面、斷面以及與其他各種管線、建筑物的相對位置。4>開工報告:開工和竣工工期、施工場地和環(huán)境、器材質(zhì)量和供貨等必備條件。5>交<完>工報告:工程質(zhì)量自檢、管孔試通抽測記錄,交〈完>工日期等。工程完工后7d內(nèi)報建設(shè)單位及時組織驗收。6>工程設(shè)計變更,質(zhì)量檢查記錄及施工過程中發(fā)現(xiàn)的重大問題,洽商記錄或決策文件。7>工程質(zhì)量事故報告:遇有重大的工程質(zhì)量事故時報告,應(yīng)闡明事故原因、責任人和采取的補救措施。8>停<復>工通知:說明停工原因,批準才能復工。9>隨工驗收記錄:內(nèi)容應(yīng)符合第8.1節(jié)的要求。10>工程初驗記錄:內(nèi)容應(yīng)符合第8.2節(jié)的要求。11>工程決算報告:控制在工程預算值以內(nèi),超預算應(yīng)有批準文件。12>驗收證書,并應(yīng)有工程質(zhì)量評語。4、驗收文件應(yīng)保證質(zhì)量,做到外觀整潔、內(nèi)容齊全、數(shù)據(jù)準確、裝訂規(guī)范。驗收中發(fā)現(xiàn)不合格的項目,應(yīng)由驗收小組按抽查規(guī)則進復查:找出原因、分清責任、提出整改和解決辦法,并在工程篡結(jié)束前得到圓滿解決。工程終驗時,應(yīng)將檢驗的主要項目列出工程終驗評價表作為驗收文件的附件。工程終驗評價表應(yīng)符合表8.3.3的規(guī)定。表8.3.3工程終驗評價表

序號檢驗項目檢驗要求檢驗結(jié)果優(yōu)良合格1管道器材附錄F序號l2管道位置附錄F序號23管道溝槽附錄F序號34管道接續(xù)附錄F序號45防水、防有害氣體附錄F序號56人<手>孔建筑附錄F序號67竣工驗收內(nèi)容附錄F序號78管孔試通附錄F序號89管孔封堵附錄F序號910人<手>孔規(guī)格附錄F序號1011核對竣工圖附錄F序號1112檢查隱蔽工程附錄F序號1213特殊情況管材選擇附錄F序號13附錄A回彈儀測量混凝土的強度A.0.1試驗用具?;貜梼x:是一種機械式的非破損測強儀器,在國內(nèi)外已經(jīng)獲得極其廣泛的應(yīng)用。其特點是結(jié)構(gòu)簡單,輕巧,便于攜帶,操作方便和測試迅速,特別適宜于野外和施工現(xiàn)場作為非破損強度檢測手段。可供一般建筑物、橋梁和工地預制廠等對各種混凝土構(gòu)件<比如板、梁、柱、桁架等>的強度控制之用。用回彈儀檢測混凝土試強度示意見圖A.0.1。A.0.2使用方法。1使用時,將回彈儀頭對準被試物體,儀器與被測物體表面垂直,輕壓后放松儀器,使按鈕彈起,彈簧桿彈出,再將儀器均勻壓向試塊,至儀器內(nèi)彈擊錘飛速運動,指釬被彈起,測量人員按動按鈕將指針固定后,可以讀出回彈值。2混凝土被、壩表面應(yīng)具有代表性,選取多個測點測試<擊點不得重合>,在測試多個點后除去最大值的一個點和最小值的一個點再求算術(shù)平均值。3查表A.0.3-1求出試塊強度。具體方法可參考儀器說明書。A.0.3混凝土強度的檢測。1在混凝土試件的邊角部分<應(yīng)盡量選擇靠近試面>,用小錘擊一缺口,立即在混凝土脫落面上滴入含量為1%?2%的酚酞試液,此時內(nèi)部未碳化的混凝土立即變紅,外部已碳化部分則不變色,不變色的深度即為混凝土的碳化深度。混凝土強度回彈值關(guān)系參照表A.0.3-1。表A.0.3-1混凝土強度與回彈值關(guān)系回彈值N混凝土強度<kg/cm2>7d以內(nèi)7d以上30d60d90d120d24.016915224.517615925.018316625.518917326.019618026.520318727.021019527.521720228.0225210100

28.523Z21810629.023922511229.524523312030.025424112710430.526124913411031.026925714411631.527726515212410232.028527416013011032.529228217013811633.030029117814612210233.530729918915413010834.031530719816413611434.532331520617214512135.033132421718215312835.534233323019216213636.034834224020217014436.535635025221018015237.036536026422l18816037.537336827623219817038.038137729024420717938.538938630225421618639.039839531626722619639.540740432927823820440.041641333629025021640.542542235l2942602264I.043443236l31827223641.544244137133228424642.045145038034629625842.546045936031027043.047046932228243.547847833629444.048848830844.549749732045.050750745.551651646.052652646.553653647.054654647.555555548.056556548.557557549.058458449.559459450.060460450.561361351.062362351.563363352.064364352.565365353.066366353.567367354.068368354.569369355.07077032混凝土構(gòu)件被測面應(yīng)具有代表性,每一被測面必須選15?20個不同的測點做回彈檢測,取回彈值的算術(shù)平均值N?;貜椘骄狄姳鞟.0.3-2。表A.0.3-2回彈平均值平均回彈值<N>15WN<2525WN<3535WN<4545WN<55允許誤差±2,5±3.0±3.5±4.0測混凝土構(gòu)件必須有足夠的剛度,否則回彈儀彈擊構(gòu)件時將發(fā)生顛動,造成測試誤差。混凝土構(gòu)件厚度宜大于10mm。A.0.4注意事項。1儀器與被測物體表面必須垂直,否則將有誤差。2被測表面應(yīng)潔凈,如有砂漿、油污、木屑等應(yīng)清除干凈,必要時可用砂輪磨平后再測試。3混凝土表面潮濕會影響測試結(jié)果,應(yīng)在混凝土表面干燥時測試。4每一測點只能測一次,不許重復。測點間與試件邊緣間至少相距30mm以上。5儀器要經(jīng)常矯正,修正誤差。附錄B水泥管塊規(guī)格和多孔塑料管端面B.0.1水泥管塊規(guī)格及示意〈圖B.0.1>。B.0.2多孔塑料端面<圖B.0.2-1,圖B.0.2-2>。附錄C常用各種標號普通混凝土參考配比C.0.1說明1本附錄是各種強度等級的普通混凝土配比及每立方米用料的額定值,不是實際工程所用混凝土的配比及用料量實際值。鑒于全國各地的砂、石料質(zhì)地各異,施工單位必須按本規(guī)范的要求,堅持"先試驗、后定配比"的原則,確定工程用混凝土的合理配比,以利于提高工程質(zhì)量、降低成本和檢驗有據(jù)。2本附錄是根據(jù)《全國統(tǒng)一建筑工程預算定額》編制的。3本附錄普通混凝土的合成料,均為符合規(guī)范要求的標準材料。本附錄表中所列混凝土標號,是以不同骨料最大粒徑劃分的。4本附錄表中所列三種標號的水泥,其中32.5水泥是普通管道工程的常用料及每立方米用料量。C.0.2預制品用普通混凝土配合比見表C.0.2。表c.0.2混凝土配合比名稱單位普通混凝土配合比<m3>C10C15C20C25C3032.5水泥kg266333383450砂子kg6936426065315?32mm卵石kg1231124512311239

水kg17018018018042.5水泥kg281321375419砂子kg7176466275765?40mm卵石kg1222125312181225水kg180180180180C.0.3一般抹灰的水泥砂漿配合比見表C.0.3。表C.0.3水泥砂漿配合比序號材料配合比〈體積比,適用范圍1石灰:砂1:2?1:3磚石墻〈人井、通道墻體,面層2水泥:石灰:砂1:0.3:3?1:1:6墻面混合砂漿打底3水泥:石灰:砂1:0.5:2?1:1:4混凝土頂棚抹混合砂漿打底4水泥:石灰:砂1:0.3:4.5?1:1:6用于檐口、勒腳及比較潮濕處墻面混合砂漿打底5水泥:砂1:2.5?1:3用于人井、通道、墻裙、勒腳等比較潮濕處地面基層抹水泥砂漿打底6水泥:砂1;2?1:2.5用于地面、頂棚或墻面面層7水泥:砂1:0.5?1:1用于混凝土地面隨即壓光c.0.4常用砌筑水泥砂漿配合比見表C.0.4。表C.0.4水泥砂漿配合比序號水泥標號砂漿強度等級M10M7.5M5127.51:5.21:6.8232.51:4.81:5.71:7.1342.51:5.51:6.71:8.6注:表中為水泥與砂比。C.0.5砌筑砂漿重量比及每立方米砌體用料量見表C.0.5。表C.0.5各種標號砂漿重量比及每立方米參考重量<kg>32.5水泥:中砂:水每立方米參考重量M5水泥砂漿1:7.1:1.601720M7.5水泥砂漿1:5.7:1.211820M10水泥砂漿1:4.8:0.981840C.0.6每立方米砌體用料量見表C.0.6。表C.0.6每立方米砌體用料量砌體磚<塊>砌塊<塊>砂漿<m3>240X115X53<mm>5200.25300X250X150<mm>119o.20300X150X150<mm>720.20C.0.7常用水泥用量換算見表C.0.7。表C.0.7常用水泥用量換算表水泥強度等級32.542.552.532.51o.860.7642.51.161o.8952.51.311.131附錄D定型人孔及體積表D.0.1定型人孔體積見表D.0.1。表D.0.1定型人孔體積表人孔程式體積<m3>人孔程式體積<m3>小號直通型10.33中號45°斜通型15.48小號三通型16.31中號60°斜通型19.16小號四通型17.17中號75°斜通型18.92小號15°斜通型10.96大號直通型22.09小號30°斜通型11.21大號三通型37.74小號45°斜通型12.00大號四通型38.08小號60°斜通型12.59大號15°斜通型22.16小號75°斜通型13.18大號30°斜通型23.78中號直通型11.59大號45°斜通型24.86中號三通型22.21大號60°斜遙型25.94中號四通型23.27大號75°斜通型27.03中號15°斜通型13.559X190手孔1.45中號30°斜通型14.19120X170手孔3.26D.0.2定型人孔土方量見表D.0.2。表D.0.2定型人孔土方量人孔名稱混凝土基礎(chǔ)無碎石地基刨挖路面<m2>挖土<m3>回土<m3>運土<m3>小號直通型27.8213.4014.4216.32三通型41.0018.5322.4720.84四通型42.8718.9023.9721.6530°斜通型32.0114.7417.2718.4145°斜通型30.3814.2316.1517.6260°斜通型32.7614.9817.7818.81中號直通型32.2714.8817.3917.63三通型53.3721.8731.5025.99四通型55.5722.2633.3126.9130°斜通型38.7817.1321.6520.9945°斜通型36.7716.2920.4820.5360°斜通型43.4017.9225.4823.72大號直通型50.1621.3828.7824.01三通型70.5128.5441.9730.05四通型73.2828.9844.3031.1030°斜通型57.1223.4133.7127.0545°斜通型58.6523.8634.7927.7260°斜通型58.93Z3.9434.9927.84D.0.3定型人孑L各部位體積見表D.0.3。表D.0.3定型人孔備部位體積表<m3>項目口圈混凝土上復四壁基礎(chǔ)抹面小號直通型0.050.6243.4710.7320.505小號三通型0.051.1215.001.0580.726小號四通型0.051.1104.5720.9500.68小號15°斜通型0.050.6504.400.780.54小號30°斜通型0.050.6604.110.750.58小號45°斜通型0.050.7334.100.6760.56小號60°斜通型0.050.8124.2090.8990.691小號75°斜通型0.050.8384.5471.1050.607中號直通型0.050.7674.2131.0270.573中號三通型0.051.2268.5621.6620.863中號四通型0.051.3058.9441.619O.866中號15°斜通型0.051.1224.4581.0260.607中號30°斜通型0.051.2284.6621.1570.622中號45°斜通型0.051.0704.8341.2370.654中號60°斜通型0.051.4277.5751.5290.919中號75°斜通型0.051.3687.9001.3830.708大號直通型0.051.5038.3931.5840.865大號三通型0.101.76011.6971.9901.065大號四通型0.101.91611.6242.1851.010大號15°斜通型0.051.4808.5441.6280.762大號30°斜通型0.101.4969.4801.7330.830大號45°斜通型0.101.8169.5551.6650.822大號60°斜通型0.101.9329.7971.8860.856大號75°斜通型0.102.0709.8071.9250.880附錄E土、石質(zhì)分類E.0.1土、石質(zhì)分類,按照國家有關(guān)規(guī)定,劃分為三類土,二類石:普通土:主要以鐵鍬挖掘,并能自行脫鏟的一般土壤。硬土:部分用鐵鍬挖掘,部分需要鐵鎬挖掘的土壤,如堅土、粘土、市區(qū)瓦礫土及淤泥深度小于0.5m水稻田的土壤等<包括雖可不用鐵鎬挖掘,但不能自行脫鍬的土壤>。砂礫土:以鎬鍬為主,有時也需要撬棍挖掘,如風化石、僵石、卵石及淤泥深度0.5?lm的水稻田等。軟石:部分用鎬挖掘,部分用爆破挖掘的石質(zhì)土,如松沙石、粘性膠結(jié)特別密實的卵石、軟化石、破裂的石灰?guī)r、硬粘土質(zhì)的片巖、頁巖和硬石膏等。堅石:全部用爆破或人工用大錘擊打方法挖掘的石質(zhì),如硬巖、玄武巖、花崗巖和石灰質(zhì)粘性的礫巖等。附錄F工程驗收項目和內(nèi)容F.0.1工程驗收項目和內(nèi)容見表F.0.1。表F.0.1工程驗收項目和內(nèi)容序號項目內(nèi)容驗收方式l管道器材<1>管塊、管材規(guī)格、材質(zhì)選擇<2>管接頭<3>膠水<4>管支架或扎帶<5>混凝土、磚、鋼筋以及各種人<手>孔器材隨工檢驗

2管道位置<1>管道設(shè)計坐標、路由<2>管道高程坡度<3>管道與相鄰管線或障礙物的最小凈距<4>管道與鐵道、有軌電車道的最小交越角隨工檢驗3管道溝槽<1>溝槽的寬度和深度<2>土質(zhì)、地基和基礎(chǔ)處理<3>冰凍層處理<4>淺埋保護<5>回填土、夯實<6>警告帶、混凝土板、普通燒結(jié)磚、蒸壓灰砂磚或蒸壓粉煤灰砂磚隨工檢驗隱蔽工程簽證4管道接續(xù)<1>管口平滑清潔<2>膠水均勻、連接牢靠<3>管材標志朝上<4>接頭錯開<5>管道接續(xù)的〈應(yīng)逐個檢查><6>管群捆綁或支架<7>管群斷面和管位一致隨工檢驗隱蔽工程簽證5防水、防有害氣體<1>管道進入建筑物應(yīng)防水和防可燃氣體<2>管道進入人孔做2m鋼筋混凝土基礎(chǔ)和包封<3>管道進入建筑物或人孔應(yīng)加管堵頭<4>管道與燃氣管交越處理隨工檢驗6人<手>孔建筑<1>符合本規(guī)范第4章規(guī)定<2>土質(zhì)、地基礎(chǔ)處理<3>管道斷面與人孔托架和托板的規(guī)格、數(shù)量相配合<4>方便布放電<光>纜隨工檢驗隱蔽工程簽證7竣工驗收內(nèi)容<1>管孔試通<2>管口封堵<3>人<手>孔裝置齊全、合格<4>核對竣工圖<5>檢查已簽證的隱蔽項目竣工驗收8管孔試通<1>直線管道管口試通<2>彎管道管孔試通<3>管7L試通抽查規(guī)則竣工驗收9管孔封堵<1>建筑物管孔封堵質(zhì)量<2>人<手>孔管孔封堵質(zhì)量<3>管堵頭拉脫力竣工驗收10人<手>孔規(guī)格<1>人<手>孔裝置符合標準<2>人<-1->孔規(guī)格、形狀和尺寸符合標準竣工驗收11核對竣工圖核對圖紙與實際是否相符竣工驗收12檢查隱蔽工程檢查隱蔽工程簽證手續(xù)是否完善竣工驗收13特殊情況管材選擇<1>高寒環(huán)境下管材選擇<2>鼠害、白蟻等地區(qū)管材的特殊要求<3>特殊施工地段管材的選擇<4>非埋地應(yīng)用管材的選擇隨工檢驗本規(guī)范用詞說明1為便于在執(zhí)行本規(guī)范條文時區(qū)別對待,對要求嚴格程度不同的用詞說明如下:1>表示很嚴格,非這樣做不可的用詞:正面詞采用"必須",反面詞采用"嚴禁"。2>表示嚴格,在正常情況下均應(yīng)這樣做的用詞:正面詞采用"應(yīng)",反面詞采用"不應(yīng)"或"不得"。3>表示允許稍有選擇,在條件許可時首先應(yīng)這樣做的甩詞:正面詞采用"宜",反面詞采用"不宜";表示有選擇,在一定條件下可以這樣做的用詞,采用"可"。2本規(guī)范中指明應(yīng)按其他有關(guān)標準、規(guī)范執(zhí)行的寫法為"應(yīng)符合……的規(guī)定"或"應(yīng)按……執(zhí)行"。通信管道工程施工及驗收規(guī)范條文說明2器材檢驗一般規(guī)定2.1.4PVC管在存放、保管時,應(yīng)平放于溫度不超過40℃的庫房或棚里,不應(yīng)露天存放,以免遭雨淋日曬。在室內(nèi)存放時,距離熱源不應(yīng)小于lm。如管材存放在0c以下的環(huán)境中,使用前應(yīng)在室溫下放置一晝夜。2.5磚燒結(jié)普通磚,按材料分為粘土磚<N>、頁巖磚<Y>、煤矸石<M>和粉煤灰磚<F>。為節(jié)省土地,工程避免使用粘土磚。2.10鋼材、鋼管與鐵件2.10.2鋼管易腐蝕,壽命短,一般用于跨路、橋梁和管道埋深達不到要求時選用。對于需要進行電磁防護地點,也可選用。3工程測量3.0.2管道施工前,根據(jù)設(shè)計圖紙和現(xiàn)場交底,由施工單位對管道及人<手>孔的位置進行認真的復測,并按施工需要釘設(shè)基準樁點。復測包括基準點、中心線測量和設(shè)置高程基準點測量等。設(shè)置的基準樁點可采用木樁作為樁點。4土方工程挖掘溝坑開挖管道溝和人<手>孔坑時,根據(jù)土質(zhì)情況、深度以及地下水位的高低,可采取不同的支撐護土板方法,以保證施工的安全順利進行。支撐護土板的方法有以下4種:1疏撐,當土質(zhì)比較堅實,挖溝深度不大時,可以采用橫疏撐。每隔4m由溝邊向下,在I/4溝深的地方橫放一塊2000mmX50mmX150mm的木板,用兩根lOOmm圓木平行頂?。蝗绻临|(zhì)不夠堅實,并且挖溝較深時,可以用豎疏撐。每隔2m沿溝槽上半部豎立一塊1000mmX50mmx150mm的木板,用兩根100mm圓木上下頂住。2井字撐,當土質(zhì)比較堅實,但距車行道或鐵路較近,受震動較大的溝槽地段,可以采用井字撐。每隔3?4m用四塊1500mmX50mmx150mm的木板組成井字形護土板支撐,四周用四根lOOmm圓木頂住。3密撐,當土質(zhì)松軟或土質(zhì)雖堅實但距車行道或鐵路較近,受震動較大的地段,以及溝邊距房屋建筑比較近時,可以采用密撐。將護土板橫向密排,每隔1?2m用一塊50minx150mm的豎木板擋住密排橫板,豎板上下兩端各用一根100mm圓木頂住。4板樁支撐,在砂土或砂地帶挖溝時,可以采用板樁支撐,板樁支撐有兩種做法:1>橫向密排護土板,每隔0.5?1m用100mm圓木,下端削尖做成木樁打人溝底至少lOOmm,再用lOOmm圓木上下頂住圓木樁。2>縱向密排水板樁,下端削尖打入溝底至少l00mm,上端用50mmX150mm木板每隔一定距離用]OOmm圓木頂住。5幾種建筑物支撐保護示例:1>房屋:挖溝<坑>前,先調(diào)查、登記管道沿線影響施工的路面障礙<如砍樹、電桿和房屋支撐保護等,如圖1、圖2>所示。并及時通知建設(shè)單位處理。2>挖溝<坑>如有與其他地下管線交越或平行,并有一定危險性的,一定要及時保護<圖3、圖4>。管道工程一般使用5?32mm粒徑的級配石子。大小粒徑石子的良好搭配,可有效的節(jié)省水泥和提高}昆凝土強度。石子級配有連續(xù)級配和單粒級配<圖5、圖6>。通信管道工程宜采用連續(xù)級配。6人<手>孔、通道建筑6.3墻體6.3.4電纜鐵支架:有甲式<長>和乙式<短>兩種。支架的規(guī)格尺寸應(yīng)符合《圖集》要求。1支架應(yīng)用鑄鋼<瑪鋼或球墨鑄鐵>型鋼或其他工程材料,不礙用鑄鐵。2電纜托板插孔內(nèi)部尺寸誤差不得大于±1mm。3全部鍍鋅處理。4電纜支架穿釘:穿釘用<}16?+20普通碳素鋼加工,要求鍍鋅處理。5V形拉力環(huán):拉力環(huán)用中16普通碳素鋼加工,要求鍍鋅處理。6積水罐:積水罐用鑄鐵加工,要求熱涂瀝青防腐處理。7電纜托板:電纜托板根據(jù)電纜大小分為單式、雙式和三式三種,用鑄鐵加工,要求鍍鋅處理

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論