VascularProtectionTrainingAdvancedClinicalTraining波科介入FilterWire中文保護(hù)傘第1頁TheProductFeaturesandIntendedBenefits波科介入FilterWire中文保護(hù)傘第2頁3of128FilterWireEZ?

EmbolicProtectionSystemTheFilterWireEZSystemisBSC’ssecondgenerationembolicprotectionfilter.ItincorporatesanumberofdesignchangesfromtheFilterWireEX?System(FirstGenerationSystem)intendedtoimprovetheeffectivenessandeaseofuse.EuropeSeptembercommercializationforSVG,nativecoronary,peripheralandcarotidinterventionDominantmarketshare(PVandCV)despitemanyotherembolicprotectionfiltercompetitorsUSAugustcommercializationforSVGinterventionIncreasedmarketshareandmarketpenetrationDecember510(k)approvedforcarotidindication波科介入FilterWire中文保護(hù)傘第3頁4of128FilterWireEZ?

SystemComponentsFilterWireEZ5.5mmSystemProtectionWireEZDeliverySheathEZRetrievalSheathAccessories

(peel-awayintroducer,guidewiretorquer,valvedilatortool)FilterWireEZBentTipRetrievalSheath

(availableseparately)波科介入FilterWire中文保護(hù)傘第4頁5of128FilterWireEZ?System

AccessoriesPeel-awayIntroducerSheathUsedtopreventdamagetothespringtipoftheprotectionwireduringsysteminsertionintoarotatingorfixedhemostasisvalve.GuideWireTorquerIntendedtoenhancetheoperator’sgripontheprotectionwireforsteerabilityduringdeliveryandtoprovideleverageduringfilterdeploymentandcapture.ValveDilatorToolUsedwithafixedhemostasisvalvetominimizedamagetothefilterbaguponremovalthroughthevalve.波科介入FilterWire中文保護(hù)傘第5頁6of128FilterWireEZ?SystemPEBAXisaregisteredtrademarkofAtofinaCorporationAtraumatic3cm,platinum,springcoiltipwithfloppyflexibilityRadiopaquetoenhancevisualizationShapeabletoenhancesteerability6.0mmPEBAX?NoseconeFlexibletransitionfromthespringtiptothedeliverysheathforexcellentoveralldeliverabilityProvidesaprofiletransitionthatisdesignedtoreducetheriskofdebrisembolizationduringsystemdelivery波科介入FilterWire中文保護(hù)傘第6頁7of128FilterWireEZ?SystemPolyurethanefiltermembranewith110micronporesDesignedtocapturesdebrisandreducetheriskofembolicrelatedeventsIntendedtopermitcontinuousbloodflowforpatientsafetyandcomfortIntendedtopermitcontinuousbloodflowthatallowscontrastinjectionsforvisualizationduringtheintervention波科介入FilterWire中文保護(hù)傘第7頁8of1285.5mm4.5mm3.5mmFilterWireEZ?SystemConforming,nitinolfilterloopwithplatinumcoilHighlyvisibletoguidefilterplacementandtoensuregoodvesselwallappositionOnedevicethataccommodatesvesselswithlandingzonediametersrangingfrom3.5mmto5.5mmminimizessizingguessworkandinventoryneedsDesignedtoprovidecontinuouswallappositionaroundthecircumferenceofthevessellumentominimizetheopportunityfordebristocollectontheoutsideofthefilterAutomaticallyadjuststochangesinthevesselaperture波科介入FilterWire中文保護(hù)傘第8頁9of128FilterWireEZ?SystemFilterloopsuspensionarmallowsthefilterlooptomoveindependentlyfromthewireforgoodvesselwallappositioninbothstraightandcurvedanatomySimplifiesthelandingzonerequirementsbyallowinguseinbothstraightandcurvedvesselsNoneedtotake2angioviewstoassessfilterapposition波科介入FilterWire中文保護(hù)傘第9頁10of128FilterWireEZ?SystemSpinnertubeunderlyingfilterassemblyAllowsthewiretorotateindependentlyfromthedeliverysheathforexcellentsystemsteerability.032”O(jiān)DCatheterstopProvidesabarrierdesignedtopreventtherapeuticdevicesfromcollapsingthefilterframeLightlyvisibletocontributetovisualizationfordevicepositioning**Note:A0.013”O(jiān)Dpart5mmproximaltothecatheterstopmayalsobevisiblewithsomeequipment.Thispartkeepsthespinnertubeinplace,butletscathetertipspassover.波科介入FilterWire中文保護(hù)傘第10頁11of128FilterWireEZ?System0.014”StainlesssteelwirebodywithPTFEcoatingAvailablein190cmand300cmwirelengths190cmwirelengthiscompatiblewithBSC’sAddWire?GuideWireSiliconecoatedondistal15cmofdevice,delivery,andretrievalsheath.Designedtoreducetheamountofforcerequiredtoloadthefilterintothedeliverysheathanddeployinthevessel波科介入FilterWire中文保護(hù)傘第11頁12of128EZ

DeliverySheath150cmPEBAX?Resinsheathwith100cm,peel-awayexchangelengthThedistalsheathchangescolorfrombluetocleartoserveasawarningthatthenonpeel-awaysectionattheendofthesheathisapproaching1.1mm(0.042”or3.2F)LesioncrossingprofileDistalendhasaPTFEinnerlinerInternalstoploadingfeature–alertstheoperatorthatthefilterisfullysheathed波科介入FilterWire中文保護(hù)傘第12頁13of128EZRetrievalSheath150cmPEBAX?Resinsheathwitha20cmlongexchangelengthSoftdistaltipDesignedtofacilitatethecapabilitytocrossdeployedstents1.4mm(0.056”or4.3F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured波科介入FilterWire中文保護(hù)傘第13頁14of128EZBentTipRetrievalSheath

(soldseparately)150cmPEBAX?Resinsheathwitha20cmexchangelengthBendatdistaltipThebendisdesignedtoaidincrossingstentstrutsthatcancomplicatefilterretrieval1.3mm(0.052”or4.0F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured波科介入FilterWire中文保護(hù)傘第14頁FilterWireEZ?

EmbolicProtectionSystemStep-by-StepInstructionsProductDemonstrationPleaserefertothe

FilterWireEZ?EmbolicProtectionSystemDFUforcompleteinstructionsforuse.波科介入FilterWire中文保護(hù)傘第15頁FilterWireEZ?EmbolicProtectionSystemDFU

availableat/filterwire

FilterWireEZ?System

DFUCard波科介入FilterWire中文保護(hù)傘第16頁17of128FilterWireEZ?EmbolicProtectionSystem

Pre-ProcedureReviewthepatient’sangiogramanddetermineifthevesselmeetstherequirementsforsafeandeffectiveuseoftheFilterWireEZSystem:Theapexoftheloopcanbedeployedaminimumof3.0cmfromthedistaledgeofthelesion.

Thevesseldiameteratthedesiredlocationofthedeployedfilterloopis3.5mmto5.5mm.(2.25mmto3.5mmforEZSmall)3.5mm–5.5mmvesseldiameter波科介入FilterWire中文保護(hù)傘第17頁18of128FilterWireEZ?EmbolicProtectionSystem

Pre-Procedure(continued)PriortousingtheFilterWireEZSystem,anticoagulatethepatienttoachieveanACTof≥275secondsforcarotidapplicationsand300secondsforSVGapplications(>200secondsifGPIIb/IIIainhibitorsareused).IntheabsenceofACTmeasurement,administeranappropriateweightbasedbolusofheparin(approximately125units/kg).波科介入FilterWire中文保護(hù)傘第18頁19of128FilterWireEZ?EmbolicProtectionSystem

Pre-Procedure(continued)RCAgraft-mostcommonlyusedguideisthemultipurpose.Marginalgraft-HockeystickguideisfirstchoicefollowedbyleftAmplatzLADorDiagonalgraft-mostcommonlyusedguidesaretheleftAmplatzandHockeystick.TakenfromMarcoet.al.“StentingofDegeneratedSaphenousVeinGrafts”MayEuroPCRBasedonvesseltake-off,physicianshouldconsiderwhichguidecathetershapewillprovidethebestaccessandsupport.波科介入FilterWire中文保護(hù)傘第19頁20of128FilterWireEZ?EmbolicProtectionSystem

PREP:DeliverySystem1.Openthepouchusingsterilehandlingprocedureandplacethepackagingcoilsandaccessorykitintothesterilefield.2.Unclipandremovetheyellowhousingthatprotectsthefilter.

Note:Theprotectionwireispre-loadedintothedeliverysheath.

3.Detachthepre-loaded

protectionwirefromtheretainingclip,advancethedeliverysheath,thengraspthe

clearsectionofthesheath

andremove

sheathedwirefromthecoil.FilterWireEZ?SystemProductPackaging波科介入FilterWire中文保護(hù)傘第20頁21of1284.SheaththeprotectionwireandfilterbyretractingthedeviceintotheEZDeliverySheathwhilethefilterisimmersedinheparinizedsaline.

NOTE:HoldtheDeliverysheathabout1cmproximaltothedarksection.NOTE:Keepthefilterunsheatheduntilimmediatelypriortouse.FilterWireEZ?EmbolicProtectionSystem

PREP:DeliverySystem(continued)3.Attachthewiretorquerontotheproximalendoftheprotectionwire.GuideWireTorquer波科介入FilterWire中文保護(hù)傘第21頁22of128FilterWireEZ?EmbolicProtectionSystem

Delivery2.InserttheFilterWireEZSystemandpeel-awayintroducerassemblyintoaguidecatheter/sheath.OncetheFilterWireEZSystemisinsertedintotheguidingcatheterorguidingsheath,removethepeel-awayintroducer.

NOTE:Useofaguidingcatheteroraguidingsheathwitha1.91mm(0.075”)orlargerrotatinghemostasisvalveisrecommendedwhenperformingaprocedurewiththeFilterWireEZSystem.Theuseofasheath/guidecatheterwithafixedhemostasisvalvemaycausethefiltermembranetotearatthehemostasisvalveuponremoval.1.Placethepeel-awayguidewireintroduceroverthetipofthedeliverysystem(thespringtipofthesystemcanbeshapedasneeded).Peel-awayIntroducerSheath波科介入FilterWire中文保護(hù)傘第22頁23of128FilterWireEZ?EmbolicProtectionSystem

Delivery(continued)3.ToadvancetheFilterWireEZSystemthroughtheguidingcatheterorguidingsheath,useaone-handedtechniqueadvancingboththedeliverysheathandprotectionwiretogether;thiswillpreventaccidentaldeploymentofthefilter.4.TosteertheFilterWireEZSystemtothetargetlandingzone,useatwo-handedtechnique,torquingtheprotectionwirewithonehandandadvancingthedeliverysheathwiththeotherhand.NOTE:Forcarotidinterventions,havingthepatientturntheirheadtotheleftorrightwillchangetheorientationofthevesselandmayfacilitatedevicepassage.

NOTE:Considerusingthebuddywiretechniqueifthelesionisdifficulttopass.RetractthebuddywireafterthelesionhasbeencrossedbytheFilterWireEZSystem(Ifothereffortsareunsuccessful,pre-dilatationcanbeused.)波科介入FilterWire中文保護(hù)傘第23頁24of128FilterWireEZ?EmbolicProtectionSystem

Delivery(continued)5. AdvancetheFilterWireEZSystemacrossthelesionuntiltheapexofthefilterloopcanbedeployedaminimumof3.0cmdistaltothelesion.NOTE:Ifaninterventionaldevicewithatip-to-shoulderlengthofgreaterthan10.0mmistobeused,alongervessellengthmayberequiredtoplacetheFilterWireEZSysteminordertoavoidcontactbetweenthefilter’scatheterstopandthetipoftheinterventionaldevice.波科介入FilterWire中文保護(hù)傘第24頁25of128Oncetheprotectionwireisinplacepastthelesion,slidethetorquertipuptothehemostaticvalveandtightenfirmly.Deploythefilterbyholdingtheprotectionwirewiththetorquer,thenretractingandcompletelyremovingthedeliverysheath.Besuretokeepthetorquerinplaceasyoupeel-awaythedeliverysheathinastraightmotionuntilthe3cmover-the-wiresectionisreached(seephotobelow).FilterWireEZ?EmbolicProtectionSystem

FilterDeploymentincorrectCORRECTPhotographtakenbyBostonScientificCorporation波科介入FilterWire中文保護(hù)傘第25頁26of1284. Oncethedeliverysheathiscompletelyremoved,injectcontrastandverifythedeviceisintheproperpositionandthereisadequateflow.

NOTE:Ifrepositioningisrequired,theEZRetrievalSheathshouldbeused.Retracttheprotectionwireandfilterloopintothesheath,repositionthefilterandredeploy.5. Usetheprotectionwirelikeatraditionalguidewiretotrackcathetersandstentdeliverysystemstothetargettreatmentarea.FilterWireEZ?EmbolicProtectionSystem

FilterDeployment(continued)波科介入FilterWire中文保護(hù)傘第26頁27of1281.Injectcontrastfrequentlyandalwaysafteranyinterventionorexchange,tovisuallyverifythatbloodflowisnotobstructedandthatfilterloop/vesselappositiontothevesselwallismaintained.

CAUTION:Ifafilterbecomesoccludedduringtheprocedure,removeitanddeployasecondfilteriffurtherinterventionisrequired.2.Completetheproceduremakingsuretheprotectionwireremainsintheproperpositiondistaltothelesion(monitorfluoroscopy).

Note:Failuretostabilizetheprotectionwirecouldleadtoinadvertentmovementofthefilter,resultinginprotectionwireentanglementand/ordelayintheprocedure.FilterWireEZ?EmbolicProtectionSystem

DuringtheProcedure波科介入FilterWire中文保護(hù)傘第27頁28of128FilterWireEZ?EmbolicProtectionSystem

FilterCaptureandRetrieval1.RemovetheEZRetrievalSheathfromitspackagingcoilandflushwithheparinizedsaline.2.Advancetheretrievalsheathovertheprotectionwirepastanydeployedstentsuptotheproximalendofthefilterloop.Note:IftheEZRetrievalSheathisnotabletopassthedeployedstent,besurethestentiswellapposedandconsiderpost-dilitation.IftheRetrievalSheathisstillunabletocross,trytheEZBentTipRetrievalSheath(availableseparately).EZBentTipRetrievalSheathPackaging波科介入FilterWire中文保護(hù)傘第28頁29of128FilterWireEZ?EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)3.Gentlyandslowlyretracttheprotectionwireandfilterloopbackintotheretrievalsheathuntilresistanceisfelt.4.Observetheretrievalprocedureunderfluoroscopicimaging.Note:Thedistaledgeofthecollapsedfilterloopshouldalignwith(seefigureB),orbeproximalto(figureA),theretrievalsheathmarkerband.

RetrievalSheathMarkerBandAB波科介入FilterWire中文保護(hù)傘第29頁30of128FilterWireEZ?EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)

NOTE:Ifresistanceisfeltbeforethedistaledgeofthecollapsedfilterloopisalignedwiththemarkerband,itispossiblethatthereisalargeamountofembolicdebrisinthefilter.CarefullyretracttheprotectionwireandEZRetrievalSheathasasystem.Thedistalpartofthefilterbagwillbeoutsideofthesheathduringretrievalinthiscase;however,thefilterloopmustbepulledfullyintothesheath.FullyRetractedFilterLargeDebrisLoadinFilter波科介入FilterWire中文保護(hù)傘第30頁31of128FilterWireEZ?EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)5.IfanyresistanceismetduringretractionofthesheathedFilterWireEZSystem,slightlyadvancethesheathedFilterWireEZSystemandrotatethesheathbeforecontinuingtoretract.6.Slowlyandcarefullyretracttheentiresystemuntilthetipoftheretrievalsheathisadjacenttothetipoftheguidingcatheterorguidingsheath.7. Ifthereisanyresistance,retracttheguidingcatheterandFilterWireEZSystemtogether.Thisisdoneincasethereisalargeamountofembolicmaterialcapturedinthefilterthatmaynotfitinsidetheguidingcatheter.波科介入FilterWire中文保護(hù)傘第31頁32of128FilterWireEZ?EmbolicProtectionSystem

FilterCaptureandRetrieval(continued)8.RemovetheFilterWireEZSystemfromthepatient. NOTE:Whenusinga

rotatinghemostasisvalve,ensurethatthehemostasisvalveisfullyopenedpriortoFilterWireEZSystemremoval.

CAUTION:Ifaguidesheathwithafixedhemostasisvalveisused,thevalvedilatortoolisrequiredforFilterWireEZSystemremoval.RemovingtheFilterWireEZSystemthroughafixedhemostasisvalvewithouttheuseofavalvedilatormaycausethefiltermembranetotear.9.Ifafixedhemostasisvalveisused,placethevalvedilator(ifprovidedintheaccessorykit)ontheshaftoftheretrievalsheathandslidethetoolintothevalve.ThenremovetheFilterWireEZSystemfromthepatientthroughthevalvedilatortoolandremovethedilator.波科介入FilterWire中文保護(hù)傘第32頁33of128StentEntanglementPotentialforadistalembolicprotectionfiltertoentanglewithastentisinherenttointerventionalproceduresusingthesedevices.SAFEPRACTICEFORDISTALPROTECTIONFILTERS:AchievegoodguidecatheterorguidesheathsupportEnsuresufficientlandingzoneKeepthefilterinplaceduringdeploymentMinimizewiremovementduringtheprocedureAchievefullstentapposition波科介入FilterWire中文保護(hù)傘第33頁34of128FilterWireEZ?EmbolicProtectionSystem

TipsforUseKeySuccessFactorsforUsingtheFilterWireEZSystemKeepACTlevels275secondsforcarotidproceduresand300secondsforSVGprocedures.Ifthereisdifficultycrossingthelesion,tryabuddywireand/or,forcarotidprocedures,havethepatientturntheirheadtotheleftorright.Forcarotidprocedures,placethefilterasdistalaspossiblewhileremainingwithintheextracranialportionoftheICA.Duringdeploymentandexchanges,stabilizethewireandwipeitfrequentlytodecreasefriction.Keepyoureyeonthefilter!Knowwhereitisandknowwhereitissupposedtobe.Verifyflowoften.Slowflow?Finishtheprocedureandremove.Noflow?Removeandreplace.TheFilterWireEZSystemneedsflowtofunction.Donottreatthelesionor“touchup”withoutaFilterWireEZSysteminplace.波科介入FilterWire中文保護(hù)傘第34頁CompetitionRXACCUNET?(Abbott)Angioguard(Cordis)Emboshield?System(Abbott)Spider(ev3)波科介入FilterWire中文保護(hù)傘第35頁36of128Competition

FixedWireFilters‘SheathedFixedWire’Devices:FilterWireEZ?System,RXAccunet?,Characteristics

Filterattachedtoa proprietarywireDeliverysheathrequiredPhotobyBostonScientific波科介入FilterWire中文保護(hù)傘第36頁37of128Competition

WireofChoiceFilters‘WireofChoice’Device:SpiderFX?Device, EmboshieldCharacteristics:Useany.014”wiretogainaccessDeliversheathedfilterandproprietaryguidewireoverthe‘wireofchoice’,thenremove‘wireofchoice’Wirecanmoveslightly(~8mmoflongitudinal“play”)withoutmovingfilterCANNOTremove/replacedeployedfilterwhilemaintainingaccessSpideRX?波科介入FilterWire中文保護(hù)傘第37頁38of128Competition

OcclusiveDevicesDistalOcclusionDevice:MedtronicGuardWire?SystemCharacteristics:ProprietarywirewithballoonattachedLowcrossingprofileBallooninflateddistaltolesionShortlandingzoneAspiratetoremoveemboliProximalOcclusionDevices:St.JudeProxis?System

CharacteristicsOcclusiveprotectionpriortocrossinglesionProxisstopsflowandthenaspiratestoremoveemboliProxis?GuardWire?波科介入FilterWire中文保護(hù)傘第38頁ImagebyBostonScientificCorp.AbbottVascularDevicesRXACCUNET?EmbolicProtectionSystem波科介入FilterWire中文保護(hù)傘第39頁40of128Competition

RXACCUNET?SystemDeliveryRetrievalFilterBagDeliverymethod:SheathedwireImagesbyBostonScientificCorp.波科介入FilterWire中文保護(hù)傘第40頁Competition

RXACCUNET?SystemFilterSizeFullyExpandedReferenceVesselDiameter(MintoMaxRange)MinimumSheathSizeMINIMUMGUIDINGCATHETERSIZE4.5mm3.25mm–4.0mm6F8F5.5mm4.0mm–5.0mm6F8F6.5mm5.0mm–6.0mm6F8F7.5mm6.0mm–7.0mm6F8FTechnicalspecsexcerptedfromRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,波科介入FilterWire中文保護(hù)傘第41頁42of128Competition

RXACCUNET?SystemFilterWireEZSystemRXACCUNETSystemDeliveryMethodSheathedwireSheathedwireCrossingProfile3.2F3.5&3.7FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm3.25mm–7.0mm(4sizes–4.5,5.5,6.5,7.5)PoreSize110micronRangesupto150micronDeviceWireCharacteristicsModeratesupportExtrasupportLandingZone>3.0cm>4.0cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.5FWireLengths190cm,300cm190cm,300cmGuideCatheterReq.6F(minID0.066”)8F(minID0.085”)IndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,波科介入FilterWire中文保護(hù)傘第42頁43of128ExcellentDeliverabilityGuidewireanddeliverysheathentervesselasoneunitHighlyflexibletonavigatetortuousanatomyLowprofileandsmoothtransitionfromtiptofilterbasket.014”wireistorquedindependentfromfilterbasketAccurateDeploymentRapidexchangeunsheathingforstabilityandsimplicityPeelawaydeliverysheathallowsforcontrolleddeploymentCaptureandControlforOptimalProtectionHighlyflexiblefilterbasketdesignedtoconformtotortuosityDesignedtocapturehighvolumewhileallowingadequatebloodflowConcentricdesignwithguidewirecenteredinfilterFourplatinumradiopaquemarkerssurroundfilterforvisualizationofwallappositionSecureFilterRetrievalChoiceoftworapidexchangerecoverycathetersdesignedspecificallyforthechallengesoffilterrecovery.RXACCUNETRecoveryCatheterShapeabledistaltipsteerscatheterfromstentstrutsduringadvancementFilterbasketsecuredwithallcagestrutopeningsenclosedduringwithdrawalRXACCUNET2RecoveryCatheterLow-profile,flexibletiptoallowfordeflectionawayfromstentstrutsduringadvancementFlexiblecatheter/shaftoptimizedforchallengingguidecatheter/sheathaccessCathetershaftmarkersat95and105cmforreducedflourotimeCompetition

RXACCUNET?SystemInformationononRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularat.波科介入FilterWire中文保護(hù)傘第43頁44of128ACCUrateCaptureandControlTheRXACCUNETSystemisdesignedtoprovideexcellentcapturecapabilitiesandeasyfiltercontrolwhenperformingcarotidstentinginterventions.TheRXACCUNETSystemisa.014”guidewirebasedfiltersystemthatutilizesrapidexchangetechnologysothatthephysiciancaneasilycontrolthefilterduringcathetermanipulations.Itisavailableinboth190cmand300cmlengthswiththeproximalendofthe190cmdevicecoinedtoallowforattachmenttoa“DOC”wireextension.Thesystemis6Fsheath/8Fguidecathetercompatibleandhasfiltersavailablein4.5,5.5,6.5,and7.5mmbasketdiametersthatarerecommendedforuseinarteriesrangingfrom3.25mmto7.0mm.TheRXACCUNETSystem’sflexiblecagedesignassistsinmaintainingexcellentwallappositioninpulsedflowenvironmentsandchallenginganatomies.TheRXACCUNETSystem’speelawaydeliverysheathallowsforsimpledeploymentwithrapidexchangeunsheathingforstabilityandeaseofuse.Additionally,the.014”wirecanbetorquedindependentlyfromthefilterbasketinordertohelpmanagethenavigationoftortuousanatomy.RecoveryisperformedwithachoiceoftwodedicatedRXrecoverycatheters.

TheoriginalRXACCUNETRecoveryCatheterhasashapeabledistaltipdesignedtooffersteeringcontrolduringadvancement.TheRXACCUNET2RecoveryCatheterislowerprofileandmoreflexibleandwasdesignedtoaccessmoretortuousanatomieswithoutcatchingonstentstruts.Competition

RXACCUNET?System

-PositioningInformationonRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,波科介入FilterWire中文保護(hù)傘第44頁ImagebyBostonScientificCorp.AbbottVascularDevicesEmboshield?BareWire?RapidExchangeEmbolicProtectionSystem波科介入FilterWire中文保護(hù)傘第45頁46of128Competition

Emboshield?SystemDeliverymethod:BareWire?Device/wirefirstCrosslesionwithprovided

BareWireDevice,thenadvanceFilterDeliveryCatheteroverBareWireDevicetodeploymentsite(note:thefiltercanonlybepositionedproximaltothe0.019”stepontheBareWireDevice)DeliveryRetrievalFilterBagImagesbyBostonScientificCorp.InformationexcerptedfromEmboshieldSystemDFU.波科介入FilterWire中文保護(hù)傘第46頁Competition

Emboshield?SystemFilterDiameterVesselSizeRangeCrossingProfile3.0mm2.8-<3.5mm3.7F4.0mm3.5-<4.2mm3.7F5.0mm4.2-<5.2mm3.9F6.0mm5.2–6.2mm3.9FSupportLevelLength(cm)Soft190,315Medium190,315Extra190,315Super190,315Maximum190,315Emboshield?SystemBareWireTechnicalspecsexcerptedfromEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,波科介入FilterWire中文保護(hù)傘第47頁48of128Competition

Emboshield?SystemFilterWireEZSystemEmboshieldSystemDeliveryMethodSheathedfilterwireBareWire?Device/wirefirstCrossingProfile3.2F3.7&3.9FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm2.8–6.2mm(4sizes–3,4,5,6)PoreSize110micron140micronDeviceWireCharacteristicsModeratesupport5supportlevels(soft,medium,extra,super,maximum)LandingZone>3.0cm>3.6–4.3cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.4FWireLengths190cm,300cm190cm,315cmGuideCatheterReq.6F(minID0.066”)7FIndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandavailableatAsofMarch10,.波科介入FilterWire中文保護(hù)傘第48頁49of128Competition

Emboshield?SystemPerceivedStrengthsPerceivedWeaknessesAbilitytocrosstightlesionsusingarelativelysimplesystem(providedguidewirewith0.019”stop)Lowcaptureefficiencyonabend1Abilitytoretrievethefilterwhileleavingthewireinplace.Significantforceisrequiredtodeliverthedevice2Multiplesizeswithvesselcoverageof2.8to6.2mmdiameterLimitedradiopacityRequirescrossingthelesiontwicepriortoprotection–firstwithBareWireandthenw/deliverycatheterIncreasedproceduraltimeLargelandingzonerequiredImagesbyBostonScientificCorp.波科介入FilterWire中文保護(hù)傘第49頁50of128InformationonEmboshieldSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,Competition

Emboshield?System-PositioningDesignedforChoice,Safety,ConfidenceWiththeBareWire?Device,thewirecrossesthelesionfirst,independentofthefilteranddeliverycatheter.Allotheractions,includingfilterplacementandretrieval,balloondilatations,andstentplacementthenoccuroverthewire.

CHOICEFiveDifferentWireSupportLevelsEachavailableintwolengthsofferlesion-specificaccessandsupportTheSupersupportBareWireDeviceispackagedwiththe EmboshieldSystemSAFETYOptimizedFitofRetrievalCathetertoWireSnugfitofcathetertiptowireenhancestrackabilityand reducesthelikelihoodofcatchingonthestent.CompleteFilterEncapsulationforthesecureremovalofdebrisEmboshield

SystemenablescompleteretrievalforthesecureremovalofdebrisCONFIDENCESupportLevelSoftMediumExtraSuperMaximum波科介入FilterWire中文保護(hù)傘第50頁SpiderFXDevicepictureexcerptedfromliteraturepublishedbyeV3andmadeavailableatasofMarch10,ev3Spi

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論