Unit6ConcreteConstruction
PartⅠIllustratedWordsandConceptsFigure6-1ASlumpTestforConcreteConsistencyFigure6-2TheGrowthofCompressiveStrengthinConcreteoverTimeFigure6-3PretensioningoftheSteelStandsintheConcreteFigure6-4PosttensioningoftheSteelStandsintheConcrete
PartⅡPassagesPassageAMakingandPlacingConcretePassageBHandlingandPlacingConcreteUnit6ConcreteConstructionPartⅠIllustratedWordsandConceptsFigure6-1ASlumpTestforConcrete
ConsistencyThehollowmetalconeisfilledwithconcreteandtampedwithrodaccordingtoastandardprocedure.Theconeiscarefullyliftedoff,allowingthewetconcretetoslumpunderitsownweight.Theslumpininchesismeasuredinthemannershown.Unit6ConcreteConstructionPartⅠIllustratedWordsandConceptsFigure6-2TheGrowthofCompressiveStrengthinConcreteoverTime
Moist-curedconcreteisstillgainingstrengthafter6months,whereasAir-driedconcretevirtuallystopscuringaltogether.Unit6ConcreteConstructionPartⅠIllustratedWordsandConceptsFigure6-3PretensioningoftheSteelStrandsintheConcrete
Pretensioning,thepretensionedsteelstrandsforabeam
Unit6ConcreteConstructionPartⅠIllustratedWordsandConceptsFigure6-4PosttensioningoftheSteelStrandsintheConcrete
Posttensioning,usingdrapedstrandstomorenearlyapproximatetheflowpathoftensileforcesinthebeam.Unit6ConcreteConstructionPartⅡ
Passages
PassageAMakingandPlacingConcreteProportioningConcreteMixesThequalityofcuredconcreteismeasuredbyanyofseveralcriteria,dependingonitsenduse.Forstructuralcolumns,beams,andslabs,compressivestrengthandstiffnessareimportant.Forpavingsandfloorslabs,surfacesmoothnessandabrasionresistancearealsoimportant;forpavingsandexteriorconcretewalls,ahighdegreeofweatherresistanceisrequired.Unit6ConcreteConstructionPartⅡ
Passages
PassageA
Watertightnessisimportantinconcretetanks,dams,andwalls.Regardlessofthecriteriontowhichoneisworking,however,therulesformakinghighqualityconcretearemuchthesame:Useclean,soundingredients;mixtheminthecorrectproportions;handlethewetconcreteproperlytoavoidsegregatingitsingredients;andcuretheconcretecarefullyundercontrolledconditions.Unit6ConcreteConstructionPartⅡ
Passages
PassageAThedesignofconcretemixturesisasciencethatcanbedescribedhereonlyinitsbroadoutlines.Thestartingpointofanymixdesignistoestablishthedesiredworkabilitycharacteristicsofthewetconcrete,thedesiredphysicalpropertiesofthecuredconcrete,andtheacceptablecostoftheconcrete,keepinginmindthatthereisnoneedtospendmoneytomakeconcretebetterthanitneedstobeforagivenapplication.Unit6ConcreteConstructionPartⅡ
Passages
PassageA
Concreteswithultimatecompressivestrengthsaslowas2000poundspersquareinch(13.8MPa)aresatisfactoryforsomefoundationelements.Concreteswithultimatecompressivestrengthsof22000psi(150MPa),producedwiththeaidofsilicafume,flyash,andsuperplasticizeradmixtures,arecurrentlybeingemployedinthecolumnsofsomehighrisebuildings,andhigherstrengthsthanthisarecertaintobedevelopedinthenearfuture.Acceptableworkabilityisachievableatanyofthesestrengthlevels.Unit6ConcreteConstructionPartⅡ
Passages
PassageAGivenapropergradationofsatisfactoryaggregates,thestrengthofcuredconcreteisprimarilydependentontheamountofcementinthemixandonthewater-cementratio.Althoughwaterisrequiredasareactantinthecuringofconcrete,muchmorewatermustbeaddedtoaconcretemixthanisneededforthehydrationofthecement,inordertogivethewetconcretethenecessaryfluidityandplasticityforplacingandfinishing.Unit6ConcreteConstructionPartⅡ
Passages
PassageATheextrawatereventuallyevaporatesfromtheconcrete,leavingmicroscopic
voidsthatimpairthestrengthandsurfacequalitiesoftheconcrete.Absolutewater-cementratiosbyweightshouldbekeptbelow0.60formostapplications,meaningthattheweightofthewaterinthemixshouldnotbemorethan60percentoftheweightofthePortlandcement.Higherwater-cementratiosthanthisareoftenfavoredbyconcreteworkersbecausetheyproduceafluidmixturethatiseasytoplaceintheforms,Unit6ConcreteConstructionPartⅡ
PassagesPassageA
buttheresultingconcreteislikelytobedeficientinstrengthandsurfacequalities.Lowwater-cementratiosmakeconcretethatisdenseandstrong,butunlessair-entrainingorwater-reducingadmixturesareincludedinthemixtoimproveitsworkability,theconcretewillnotfloweasilyintotheformsandwillhavelargevoids.Itisimportantthatconcretebeformulatedwiththerightquantityofwaterforeachsituation,enoughtoassureworkabilitybutnotenoughtoadverselyaffectthefinalpropertiesofthematerial.Unit6ConcreteConstructionPartⅡ
Passages
PassageAMostconcreteinNorthAmericaisproportionedatcentralbatchplants,usingup-to-datelaboratoryequipmentandengineeringknowledgetoproduceconcreteoftheproperqualityforeachproject.Theconcreteistransitmixedenrouteinarotatingdrumonthebackofatrucksothatitisreadytopourbythetimeitreachesthejobsite.Unit6ConcreteConstructionPartⅡ
Passages
PassageAEachloadoftransit-mixedconcreteisdeliveredwithacertificatefromthebatchplantthatlistsitsingredientsandtheirproportions.Asafurthercheckonquality,aslumptest(seeFigure6-1)maybeperformedatthetimeofpouringtodetermineifthedesireddegreeofworkabilityhasbeenachievedwithoutmakingtheconcretetoowet.Unit6ConcreteConstructionPartⅡ
Passages
PassageAForstructuralconcrete,standardtestcylindersarealsopouredfromeachtruckload.Within48hoursofpouring,thecylindersaretakentoatestinglaboratory,curedforaspecifiedperiodunderstandardconditions,andtestedforcompressivestrength.Ifthelaboratoryresultsarenotuptotherequiredstandard,testcoresaredrilledfromtheactualmembersmadefromthequestionablebatchofconcrete.Unit6ConcreteConstructionPartⅡ
Passages
PassageAIfthestrengthofthesecoresamplesisalsodeficient,thecontractorwillberequiredtocutoutthedefectiveconcreteandreplaceit.Frequently,testcylindersarealsocastandcuredontheconstructionsiteunderthesameconditionsastheconcreteintheforms;thesemaythenbetestedasawayofdeterminingwhentheconcreteisstrongenoughtoallowremovalofformsandtemporarysupports.Unit6ConcreteConstructionPartⅡ
Passages
PassageBHandlingandPlacingConcreteFreshlymixedconcreteisnotaliquid,butaslurry,anunstablemixtureofsolidsandliquids.Ifitisvibratedexcessively,droppedfromverymuchofaheight,ormovedhorizontallyforanysubstantialdistanceinformwork,itislikelytosegregate,whichmeansthatthecoarseaggregateworksitswaytothebottomoftheformandthewaterandcementpasterisetothetop.Unit6ConcreteConstructionPartⅡ
Passages
PassageBTheresultisconcreteofnonuniformandgenerallyunsatisfactoryproperties.Segregationispreventedbydepositingtheconcrete,freshfromthemixer,asclosetoitsfinalpositionaspossible.Ifconcretemustbedroppedadistanceofmorethan3or4feet(ameterorso),
itshouldbedepositedthroughdropchutesthatbreakthefalloftheconcrete.Ifconcretemustbemovedalargehorizontaldistancetoreachinaccessibleareasoftheformwork,itshouldbepumpedthroughhosesorconveyedinbucketsorbuggies,ratherthanpushedacrossorthroughtheformwork.Unit6ConcreteConstructionPartⅡ
Passages
PassageBConcretemustbeconsolidatedintheformstoeliminatetrappedairandtofillcompletelyaroundthereinforcingbarsandintoallthecornersoftheformwork.Thismaybedonebyrepeatedlythrustingarod,spade,orimmersion-typevibratorintotheconcreteatcloselyspacedintervalsthroughouttheformwork.Excessiveagitationoftheconcretemustbeavoided,however,orsegregationwilloccur.Unit6ConcreteConstructionPartⅡ
Passages
PassageBSelf-consolidatingconcrete,whichfillsformscompletelywithoutrequiringvibration,hasrecentlybeendeveloped.Itisformulatedwithmorefineaggregatesthancoarseones,whichisareversaloftheusualpropotions.Itincludessuperplasticizingadmixturesthatarebasedonpolycarboxylateethers.Theresultisaconcretethatflowsveryfreely,yetdoesnotallowitscoarseaggregatetosinktothebottomoftheforms.Unit6ConcreteConstructionPartⅡ
Passages
PassageBCuringConcreteBecauseconcretecuresbyhydrationandnotbydrying,itisessentialthatitbekeptmoistuntilitsrequiredstrengthisachieved.Thecuringreactiontakesplaceoveraverylongperiodoftime,butconcreteiscommonlydesignedonthebasisofthestrengththatitreachesafter28days(4weeks)ofcuring.Ifitisallowedtodryatanypointduringthistimeperiod,Unit6ConcreteConstructionPartⅡ
Passages
PassageBthestrengthofthecuredconcretewillbereduced,anditssurfacehardnessanddurabilityarelikelytobeadverselyaffected(seeFigure6-2).Concreteelementscastinformworkareprotectedfromdehydrationonmostoftheirsurfacesbytheformwork,butthetopsurfacesmustbekeptmoistbyrepeatedlysprayingorfloodingwithwater,bycoveringwithmoisture-resistantsheetsofpaperorfilmorbysprayingonacuringcompoundthatsealsthesurfaceoftheconcreteagainstlossofmoisture.Unit6ConcreteConstructionPartⅡ
Passages
PassageBThesemeasuresareparticularlyimportantforconcreteslabs,whoselargesurfaceareasmakethemespeciallysusceptibletodrying.Prematuredryingisaparticulardangerwhenslabsarepouredinhotorwindyweather,whichcancauseaslabtocrackevenbeforeitbeginstocure.Temporarywindbreaksmayhavetobeerected,shademayhavetobeprovided,andfrequentfoggingofthesurfaceoftheslabwithafinesprayofwatermayberequireduntiltheslabishardenoughtobecoveredorsprayedwithcuringcompound.Unit6ConcreteConstructionPartⅡ
Passages
PassageBFormworkBecauseconcreteisputinplaceasashapelessslurrywithnophysicalstrength,itmustbeshapedandsupportedbyformworkuntilithascuredsufficientlytosupportitself.Formworkisusuallymadeofwood,metal,orplastic.Itisconstructedasanegativeoftheshapeintendedfortheconcrete.Unit6ConcreteConstructionPartⅡ
Passages
PassageBFormworkforabeamorslabservesasatemporaryworkingsurfaceduringtheconstructionprocessandasthetemporarymeansofsupportforreinforcingbars.Formworkmustbestrongenoughtosupporttheconsiderableweightandfluidpressureofwetconcretewithoutexcessivedeflection,whichoftenrequirestemporary
supportsthataremajorstructuresinthemselves.Unit6ConcreteConstructionPartⅡ
Passages
PassageB
Duringcuring,theformworkhelpstoretainthenecessary
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 企業(yè)公司授權(quán)管理制度
- loto作業(yè)管理制度
- 小學(xué)介詞提升題目及答案
- ts內(nèi)部客戶管理制度
- 業(yè)務(wù)風(fēng)險控制管理制度
- 不定工時員工管理制度
- 人才公寓裝修管理制度
- 中小學(xué)教育論文集
- 社會實(shí)踐個人實(shí)踐報告
- 實(shí)現(xiàn)能源生產(chǎn)與消費(fèi)的數(shù)字化轉(zhuǎn)型
- 公安警情處置流程
- 油罐換底工程施工及方案
- 2024年貴州省黔南州事業(yè)單位歷年管理單位遴選500模擬題附帶答案詳解
- 大型展會展臺搭建管理細(xì)則(3篇)
- 《檔案信息化建設(shè)》課件
- 【MOOC】工程經(jīng)濟(jì)-浙江工業(yè)大學(xué) 中國大學(xué)慕課MOOC答案
- 《壽險的功能與意義》課件
- 2024-2030年全球及中國鋰云母行業(yè)發(fā)展動態(tài)及投資前景預(yù)測報告
- 《國際中文教材評價標(biāo)準(zhǔn)》
- 城市更新項(xiàng)目造價咨詢服務(wù)方案
- 消防工程火災(zāi)自動報警及聯(lián)動控制系統(tǒng)安裝施工方案
評論
0/150
提交評論