JJF(陜) 118-2024 氧化還原電位滴定儀校準(zhǔn)規(guī)范_第1頁(yè)
JJF(陜) 118-2024 氧化還原電位滴定儀校準(zhǔn)規(guī)范_第2頁(yè)
JJF(陜) 118-2024 氧化還原電位滴定儀校準(zhǔn)規(guī)范_第3頁(yè)
JJF(陜) 118-2024 氧化還原電位滴定儀校準(zhǔn)規(guī)范_第4頁(yè)
JJF(陜) 118-2024 氧化還原電位滴定儀校準(zhǔn)規(guī)范_第5頁(yè)
已閱讀5頁(yè),還剩33頁(yè)未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

陜西省地方計(jì)量技術(shù)規(guī)范CalibrationSpecificationforOxidation-red陜西省市場(chǎng)監(jiān)督管理局發(fā)布JJF(陜)118-2024氧化還原電位滴定儀校準(zhǔn)規(guī)范JJF(陜)118-2024JJF(陜)118-2024 (3) (3) (3) (3) (4) (5) (5) (5) (5) (6) (6) (7) (7) (8) (9) (9) (9) (9) (10) (11) (13) (16) (18)本規(guī)范依據(jù)JJF1071—2010《國(guó)家計(jì)量校準(zhǔn)規(guī)范編寫(xiě)規(guī)則》、JJF1001—2011《通用計(jì)量術(shù)語(yǔ)及定義》、JJF1059.1—2012《測(cè)量不確定度評(píng)定與表示》等基礎(chǔ)性系列規(guī)范文件進(jìn)本規(guī)范校準(zhǔn)方法及計(jì)量特性等主要參考了JJG814—2015《自動(dòng)電位滴定儀》、JJG119—2018《實(shí)驗(yàn)室pH(酸度)計(jì)》、GB/T20245.5—2013《電化學(xué)分析儀器性能表示第5部分:氧化還原電位》的技術(shù)要求和試驗(yàn)方法的相關(guān)條款。本規(guī)范為首次發(fā)布。JJF(陜)118-2024氧化還原電位滴定儀校準(zhǔn)規(guī)范凡是注日期的引用文件,僅注日期的版本適用于本規(guī)范;凡不注日期的引用文件,其最氧化還原體系由給定溶液中的各種氧化態(tài)和還原態(tài)物質(zhì)組成,僅當(dāng)溶液中的電化學(xué)活性3.1.2參比電極referenc參比電極是由內(nèi)充溶液組成固定、可逆性好,在電化學(xué)測(cè)試中電位保持穩(wěn)定的電極。常3.1.3氧化還原電極redox氧化還原電極是一種表面惰性的電極,氧化還原體系中的電化學(xué)活性物質(zhì)在其表面交換氧化還原電位滴定法的原理是:選用適當(dāng)?shù)闹甘倦姌O和參比電極與被測(cè)溶液組成一個(gè)工作電池,隨著滴定劑的加入,由于發(fā)生化學(xué)反應(yīng),被測(cè)離子的濃度不斷發(fā)生變化,因而指示電極的電位隨之變化。在滴定終點(diǎn)附近,被測(cè)離子完全反應(yīng),引起電極電位的突躍。因此,JJF(陜)118-20244圖1氧化還原滴定曲線示意圖通過(guò)測(cè)量指示電極與參比電極間的電位,進(jìn)斷滴定終點(diǎn)后,儀器自動(dòng)停止滴定。滴定系統(tǒng)分為數(shù)字式和刻度式滴定管兩大類(lèi)。電極系統(tǒng)表1儀器計(jì)量特性計(jì)量性能要求電計(jì)示值最大允許誤差/%FS±0.5電計(jì)示值重復(fù)性/%≤0.25電計(jì)輸入電流/A≤6×10-12電計(jì)輸入阻抗/Ω≥1×1011儀器示值最大允許誤差/%±2.5儀器示值重復(fù)性/%≤0.5表2滴定管容量最大允許誤差滴定管標(biāo)稱總?cè)萘縨L25202550滴定管容量最大允許誤差mL±0.020±0.020±0.050±0.060±0.070±0.08±0.10±0.20注:以上指標(biāo)不用于合格性判別,僅供參考。JJF(陜)118-202456.2.1pH計(jì)檢定儀(以下簡(jiǎn)稱檢定儀):準(zhǔn)確度0.0006將滴定儀平穩(wěn)地置于工作臺(tái)上,檢查各緊固件緊固良好、各部件間的電纜線、接插線緊密可靠,滴定系統(tǒng)中各連接件配合緊密,無(wú)漏液、滲液的現(xiàn)象,液路中無(wú)氣泡存在。使用的按圖2接好線路,接通開(kāi)關(guān)K,高阻R短路,調(diào)節(jié)檢定儀,使其輸出標(biāo)準(zhǔn)電位信號(hào)值Eb,輸入儀器電計(jì),測(cè)量并記錄電計(jì)讀數(shù)。校準(zhǔn)點(diǎn)為0mV、±10mV、± JJF(陜)118-2024×100(1) Ea——電計(jì)示值平均值,mV;Eb——標(biāo)準(zhǔn)電位信號(hào)值,mV;圖2電計(jì)校準(zhǔn)線路示意圖和-600mV電壓信號(hào),同時(shí)分別記下電計(jì)示值Ei。上述操作示值重復(fù)性sr。其中,取較大值為電計(jì)示值重復(fù)性。Ei——i組測(cè)量的電計(jì)示值,mV; Ei——n次測(cè)量的電計(jì)示值平均值,mV。壓信號(hào),記錄電計(jì)示值E0;斷開(kāi)開(kāi)關(guān)K,高阻R接通,重新調(diào)節(jié)檢定儀使其輸出600mV的信JJF(陜)118-2024號(hào),記錄電計(jì)示值E1。如此操作重復(fù)3次,分別計(jì)算E0和E1的平均值E0和E1。按公式(3)計(jì)算電計(jì)的輸人阻抗Rd。(3)Rd——電計(jì)的輸入阻抗,Ω; E0——電計(jì)示值E0的平均值,mV; R——檢定儀高阻R的阻值,Ω。用同樣的方法,校準(zhǔn)輸入-600mV標(biāo)準(zhǔn)信號(hào)時(shí),儀器輸入阻抗R'd。取Rd和R'd中較小值按圖2接好線路,接通開(kāi)關(guān)K,高阻R短路,調(diào)節(jié)檢定儀,使其輸出零電位,記錄儀器電計(jì)示值;然后斷開(kāi)開(kāi)關(guān)K,高阻R接通,再次記錄儀器電計(jì)示值。計(jì)算電計(jì)示值變化量ΔE。 3(4)I——電計(jì)的輸入電流,A; R——檢定儀高阻R的阻值,Ω。首先將滴定系統(tǒng)液路采用適當(dāng)洗滌劑(如重鉻酸鉀洗液、酒精或乙醚等)洗凈,并用蒸溫與室溫之差不得大于2℃)接入稱量杯,蓋好蓋后用天平進(jìn)行稱量,記錄天平讀數(shù)m1。根JJF(陜)118-20248(5)測(cè)量純水的溫度t,根據(jù)附錄B查得水溫對(duì)滴定管容量校準(zhǔn)的影響系數(shù)K(t)(滴定系統(tǒng)為ΔV-m.K(t)(6)ΔVK(t)——(水的溫度為t時(shí))水溫對(duì)滴定管容量校準(zhǔn)的影響系數(shù),mL/每個(gè)校準(zhǔn)點(diǎn)校準(zhǔn)2次,并取2平均值為滴定管在標(biāo)準(zhǔn)溫度20℃時(shí)容量誤差ΔV。按上述校定”模式和滴定終點(diǎn)。用分度吸量管或單標(biāo)線吸量管吸取一定體積(例如20mL)的碘標(biāo)準(zhǔn)物 計(jì)算儀器示值重復(fù)性sR。 JJF(陜)118-2024c——碘標(biāo)準(zhǔn)物質(zhì)的儀器測(cè)量值,mol·L cs——碘標(biāo)準(zhǔn)物質(zhì)的標(biāo)準(zhǔn)值,mol·L-1;sR——儀器示值重復(fù)性,%。要求,并給出各校準(zhǔn)項(xiàng)目名稱和測(cè)量結(jié)果以及擴(kuò)展不確定度。校準(zhǔn)原始記錄(推薦)格式見(jiàn)分析儀校準(zhǔn)結(jié)果的不確定度按JJF1059.1—2012的要求評(píng)定,校準(zhǔn)結(jié)果不確定由于氧化還原電位滴定儀復(fù)校時(shí)間間隔是由儀器的使用情況、使用者、儀器本身質(zhì)諸多因素所決定的,因此使用單位可根據(jù)實(shí)際使用情況自主決定復(fù)校時(shí)間間隔,建議一般不超過(guò)1年。如果儀器主要零部件有修理或者更換JJF(陜)118-2024表A.1滴定管的校準(zhǔn)分段單位:mL滴定管的容量校準(zhǔn)分段50~2.50~50~5200~50~20250~50~200~25500~200~300~400~500~200~400~600~80JJF(陜)118-2024表B.1*鈉鈣玻璃量器衡量法K(t)值表(鈉鈣玻璃體膨脹系數(shù),取25×10-6℃-1,空氣密度0.0012g/cm3)溫t/℃0.00.10.20.30.40.50.60.70.80.91.002081.002091.002101.002111.002131.002141.002151.002171.002181.002191.002211.002221.002231.002251.002261.002281.002291.002301.002321.002331.002351.002361.002381.002391.002411.002421.002441.002461.002471.002491.002511.002521.002541.002551.002571.002581.002601.002621.002631.002651.002671.002681.002701.002721.002741.002761.002771.002791.002811.00283201.002851.002871.002891.002911.002921.002941.002961.002981.003001.00302211.003041.003061.003081.003101.003121.003141.003151.003171.003191.00321221.003231.003251.003271.003291.003311.003331.003351.003371.003391.00341231.003441.003461.003481.003501.003521.003541.003561.003591.003611.00363241.003661.003681.003701.003721.003741.003761.003791.003811.003831.00386251.003891.003911.003931.003951.003971.004001.004021.004041.004071.00409JJF(陜)118-2024表B.2*硼硅玻璃量器衡量法K(t)值表(鈉鈣玻璃體膨脹系數(shù),取25×10-6℃-1,空氣密度0.0012g/cm3)溫t/℃0.00.10.20.30.40.50.60.70.80.91.002001.002011.002031.002041.002061.002071.002091.002101.002121.002131.002151.002161.002181.002191.002211.002221.002241.002251.002271.002291.002301.002321.002341.002351.002371.002391.002401.002421.002441.002461.002471.002491.002511.002531.002541.002561.002581.002601.002621.002641.002661.002671.002691.002711.002731.002751.002771.002791.002811.00283201.002851.002861.002881.002901.002921.002941.002961.002981.003001.00303211.003051.003071.003091.003111.003131.003151.003171.003191.003221.00324221.003271.003291.003311.003331.003351.003371.003391.003411.003431.00346231.003491.003511.003531.003551.003571.003591.003621.003641.003661.00369241.003721.003741.003761.003781.003811.003831.003861.003881.003911.00394251.003971.003991.004011.004031.004051.004081.004101.001431.004161.00419“*”引用JJG196—2006《常用玻璃量器》JJF(陜)118-2024原始記錄號(hào)證書(shū)編號(hào)委托單位型號(hào)規(guī)格出廠編號(hào)制造廠電極型號(hào)電極編號(hào)校準(zhǔn)依據(jù)校準(zhǔn)時(shí)間校準(zhǔn)地點(diǎn)環(huán)境溫度相對(duì)濕度備注本次校準(zhǔn)所用的計(jì)量標(biāo)準(zhǔn)器名稱型號(hào)規(guī)格測(cè)量范圍不確定度或準(zhǔn)確度等級(jí)或最大允許誤差證書(shū)編號(hào)有效期至通用技術(shù)要求外觀及常規(guī)檢查通電檢查1.電計(jì)示值誤差滿量程電位值:mV標(biāo)稱值mV電計(jì)示值mV平均值mV電計(jì)示值誤差%FS備注122.電計(jì)示值重復(fù)性Ω設(shè)置mV電計(jì)示值mV備注123456789平均值99-6003.電計(jì)輸入阻抗串聯(lián)電阻Ω電位設(shè)置mV電計(jì)示值mVR輸入/Ω?jìng)渥?23平均值090-6009-6004.電計(jì)輸入電流串聯(lián)電阻Ω電計(jì)示值變化量△EmV輸入電流A備注123平均值095.滴定管容量誤差滴定管容量:mL水溫:℃K(t):mL/g校準(zhǔn)分段mL空瓶質(zhì)量m0g接入純水后純水質(zhì)量mg20℃容量值mL容量誤差ΔVmL備注0~50~206.儀器示值誤差及重復(fù)性所用Na2S2O3濃度標(biāo)準(zhǔn)值:mol·L-1碘濃度標(biāo)準(zhǔn)值mol·L-1碘濃度測(cè)量值mol·L-1平均值mol·L-1示值誤差%示值重復(fù)性%備注123456電計(jì)示值誤差不確定度Ur=(k=2)儀器示值誤差不確定度Ur=(k=2)JJF(陜)118-2024b)實(shí)驗(yàn)室的名稱和地址;);),h)如果與校準(zhǔn)結(jié)果的有效性和應(yīng)用有關(guān)時(shí),應(yīng)對(duì)被校樣品的抽樣程序進(jìn)行j)本次校準(zhǔn)所用測(cè)量標(biāo)準(zhǔn)的溯源性及有效性說(shuō)明;p)未經(jīng)校準(zhǔn)實(shí)驗(yàn)室書(shū)面批準(zhǔn),不得部分復(fù)制校準(zhǔn)證書(shū)的聲明。JJF(陜)118-20241234567電計(jì)示值誤差不確定度:Ur=儀器示值誤差不確定度:Ur=(k=2)JJF(陜)118-2024電計(jì)測(cè)量平均值主要不確定度來(lái)源于儀器測(cè)量重復(fù)性引入的不確定度u1及儀器分辨力引入的不確定度u2,且不相關(guān)。(1)儀器測(cè)量電計(jì)示值重復(fù)性引入的不確定度u1依據(jù)JJF(陜)XXX-XXXX《氧化還原電位滴定儀校準(zhǔn)規(guī)范》電計(jì)示值測(cè)量結(jié)果如表表E.1電計(jì)示值測(cè)量結(jié)果測(cè)量次數(shù)123456789測(cè)量值mV601.8601.1602.6602.

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論