1、暖通主要設備材料表一一新風機組序號設備型式冷量(kw)執(zhí)八、量(kw)送/排風量(m3/h)機外靜余壓(Pa)電機容量(kw)電壓(V)盤管空氣進口溫度(C)冷水進/出水溫(C)熱水進/出水溫(C)噪聲dB(A)(kg)數量(臺)加濕量(kg/h)供冷工況供熱工況干球濕球PAU-1B-01叉流板式熱回收新風機組91838000/65004704/2.23802925.9-116/1155/45678201一PAU-1B-02叉流板式熱回收新風機組31283600/36005301.5/1.53802926.9-116/1155/45645601一PAU-1B-03新風機組頻風機)(變20225
2、6160004722.2X238033.426.9-116/1155/456713801一PAU-1B-04新風機組(雙風機分控)1011288000(16000)4702.2X238033.426.9-116/1155/456713801一PAU-1B-05新風機組(雙風機分控)76966000(12000)4501.5X238033.426.9-116/1155/456710001一PAU-1B-06新風機組(雙風機分控)63805000(10000)3201.1X238033.426.9-116/1155/45629001一PAU-1F-01風冷型雙溫新風機組5454.43400/300
3、04307.138033.426.9-116/1155/4563560120AHU-1F-02干式空調機組7.61.230002651.138026201815/2055/45634804一PAU-1F-03風冷型雙溫新風機組36322000/20003204.938033.426.9-116/1155/4556.5440112PAU-1F-04風冷型雙溫新風機組1441498000/720052017.538033.426.9-116/1155/4567820148AHU-1F-05空調機組8874220005584X23802618.7186/1155/457118401一AHU-1F-0
4、6風冷型雙溫空調機組664810000/300044621.638026.520.413.66/1155/4563900112PAU-1F-07風冷型雙溫新風機組36322000/20002094.938033.426.9-116/1155/4555440112PAU-1F-08風冷型雙溫新風機組54483000/30003807.138033.426.9-116/1155/4563480118AHU-1F-09風冷型雙溫空調機組53456800/270045517.538028.422.313.66/1155/4564800116PAU-1F-10風冷型雙溫新風機組90805000/5000
5、43011.238033.426.9-116/1155/4565580130AHU-1F-11空調機組6528160004723X23802618.7186/1155/457313801一PAU-1F-12風冷型雙溫新風機850053021.638033.426.9-116/1155/4568900160PAU-1F-13風冷型雙溫新風機組54563500/33004508.638033.426.9-116/1155/4564560121PAU-1F-14風冷型雙溫新風機組951127000/700052017.538033.426.9-116/1155/456780
6、0148AHU-1F-15風冷型雙溫空調機組24.6163200/9003207.138027.320.7186/1155/455856015.4PAU-1F-16風冷型雙溫新風機組72644000/34005208.638033.426.9-116/1155/4564560124PAU-2F-01風冷型雙溫新風機組72644000/44005308.638033.426.9-116/1155/4564560124PAU-2F-02風冷型雙溫新風機組50452800/28005007.138033.426.9-116/1155/4563440117PAU-2F-03風冷型雙溫新風機組54483
7、000/30005007.138033.426.9-116/1155/4563440118PAU-2F-04風冷型雙溫新風機組36322000/20005004.938033.426.9-116/1155/4556.5400112PAU-2F-05風冷型雙溫新風機組21619212000/1200055027.838033.426.9-116/1155/4569860172PAU-2F-06引艾風量新風機組7910062005002.238033.426.9-116/1155/45675801一PAU-2F-07風冷型雙溫新風機組43392400/24005007.138033.426.9-1
8、16/1155/4563440114AHU-2F-08干式空調機組7.61.230005001.138026201815/2055/45634401一PAU-2F-09風冷型雙溫新風機組1401207500/870067517.538033.426.9-116/1155/4572.5740145PAU-2F-10風冷型雙溫新風機組83744600/460050011.238033.426.9-116/1155/4565520227AHU-2F-11空調機組6528160006353X23802618.7186/1155/457312801一PAU-2F-12風冷型雙溫新風機組150135840
9、0/840054521.638033.426.9-116/1155/4568.5780148PAU-2F-13風冷型雙溫新風機組1501359000/900054521.638033.426.9-116/1155/4568.5780148PAU-3F-01風冷型雙溫新風機組54402500/25005007.138033.426.9-116/1155/4563480115PAU-3F-02風冷型雙溫72644000/40005308.638033.426.9-116/1155/4564560124新風機組PAU-3F-03風冷型雙溫新風機組108966000/600050013.538033.
10、426.9-116/1155/4567700136PAU-3F-04風冷型雙溫新風機組1621449000/900054521.638033.426.9-116/1155/4568.5860154PAU-3F-05風冷型雙溫新風機1000050021.638033.426.9-116/1155/4568900160PAU-3F-06風冷型雙溫新風機組90805000/500043011.238033.426.9-116/1155/4565580130PAU-4F-01風冷型雙溫新風機組49.7644000/30005308.638033.426.9-116/1155/
11、4564560124PAU-4F-02風冷型雙溫新風機組24.9322000/16005004.938033.426.9-116/1155/4556.5440112AHU-4F-02叉流板式熱回收新風機120005004/2.238033.426.9-116/1155/45691360190AHU-4F-03叉流板式熱回收新風機組113.41449000/72005451.5/1.538033.426.9-116/1155/4568.5860154AHU-4F-01風冷型雙溫新風機組31540025000/2000055020.038033.426.9-116/115
12、5/457517001150PAU-4F-04風冷型雙溫新風機組63805000/400050011.238033.426.9-116/1155/4565520130PAU-4F-05風冷型雙溫新風機組75.6966000/480050013.538033.426.9-116/1155/4567580136PAU-4F-06風冷型雙溫37.8483000/24005007.138033.426.9-116/1155/4563440118新風機組PAU-4F-07風冷型雙溫新風機組25.2322000/16005004.938033.426.9-116/1155/4556.5400112AHU-
13、5F-01風冷型雙溫可艾風量空調機組(變頻)70577000/30006758.138027.822.110.26/1155/4572.5800112AHU-14F-01風冷型雙溫空調機組38386000/20005008.138027.822.110.26/1155/4567700112PAU-XF-01新風機組(立式)62938033.426.9-116/1155/45654401234.8PAU-XF-02新風機組(立式)49.764400053013.538033.426.9-116/1155/45643501227.8PAU-XF-03新風機組(吊頂式)37
14、.34830005007.138033.426.9-116/1155/45632002420.9暖通主要設備材料表一一風機盤管設備型式設備型式(m3/h)電機容量(W)制冷量噪聲dB(A)中速冷量(W)冷水進/出水溫(C)空氣進口溫度(C)水流量(L/S)水流阻力(kpa)出口靜壓(pa)熱量(W)熱水進/出水溫(C)進口干球溫度(C)干球濕球臥式暗裝20028011(15)76915/202618.70.040112(30)135055/452036臥式暗裝30041517(20)119015/202618.70.060212(30)203055/452038.5臥式暗裝40056023(2
15、6)160315/202618.70.080312(30)271055/452040臥式暗裝50067529(35)204515/202618.70.100512(30)225355/452043臥式暗裝60076539(44)245415/202618.70.120712(30)405555/452045臥式暗裝800109052(62)345615/202618.70.2001012(30)543055/452046臥式暗裝1000135557(69)430015/202618.70.240612(30)676055/452048臥式暗裝1200165086(90)506615/20261
16、8.70.3001012(30)811055/452049注:()內為高靜壓風機盤管。根據設計要求,施工圖中的接風道的風機盤管為高靜壓風機盤管。設備型式風道尺寸HxD(mnixmm)送風口尺寸HXD(mm<mm)門校式回風口尺寸HxD(mmxmm)回風口安裝光觸媒空氣凈化器數量(臺)側送風口散流器送風口尺寸(mmxmmmm)電量(W)電壓(V)風阻(pa)不含新風含新風一個散流器兩個散流器臥式暗500x150500X150800X150200X200150X150800x300800x300x1008220636裝200(500x150)(500X150)(800X150)(200X20
17、0)(150X15C)(800x300)(800x300x10()(8)(220)(6)(169)臥式暗600X150600X150900X150250X250200X200900x300900x300x1008220686裝300(600X150)(600X150)(900X150)(250X250)(200X200)(900x300)(900x300x100)(8)(220)(6)(157)臥式暗700X150700X1501000X150300X300200X2001000x3001000x300x100)8220655裝400(700X150)(700X150)(1000X150)(3
18、00X300)(200X200)(1000x300)(1000x300x1()0(8)(220)(6)(47)臥式暗800X150800X1501100X150300X300200X2001100x3001100x300x100)82206116裝500(800X150)(800X150)(1100X150)(300X300)(200X200)(1100x300)(1100x300x1()0(8)(220)(6)(15)臥式暗900X150900X1501200X150350X350250X2501200x3001200x300x100)82206136裝600(900X150)(900X15
19、0)(1200X150)(350X350)(250X250)(1200x300)(1200x300x1()0(8)(220)(6)(76)臥式暗1200X1501200X1501500X150400X400300X3001500X3001500x300x100)82206354裝800(1200X150)(1200X150)(1500X150)(400X400)(300X300)(1500X300)(1500x300x1()0(8)(220)(6)(149)臥式暗1500X1501500X1501800X150450X450300X3001800x3001800x300x100)8220665
20、裝1000(1500X150)(1500X150)(1800X150)(450X450)(300X300)(1800x300)(1800x300x1()0)8)(220)(6)(74)臥式暗1700X1501700X1502000X150500X500350X3502000X3002000x300x100)822066裝1200(1700X150)(1700X150)(2000X150)(500X500)(350X350)(2000X300)(2000x300x1()0(8)(220)(6)(20)總體要求:1,空調機組、新風機組、風機盤管選用低噪聲設備。2,采用熱回收型新風機組或空調機組,具
21、額定熱回收效率n60%。3,所有空調系統(tǒng)均可實現可調新風比及過渡季全新風運行。4,空調冷水系統(tǒng)設計工況ER=0.0197<0.0241(降低36%)。5,風冷型雙溫新風機組自帶控制箱。要求具備DDC樓控接口,具備機組設備的短路、過載、斷相等保護功能6,控制箱至設備管線由設備供應商自理。7,無熱回收裝置的新風機組,新風進口設電動閥,其余新風機組、組合式空調機組所需電動閥,均機組自帶。8,新風機組、組合式空調機組所需強、弱電控制柜均機組自帶。9,吊頂內風機盤管電源均預留在吊頂內,其至空調調速開關的管線均由設備供應商自理,預埋JDG25/KG25(由總包完成預埋),調速開關底邊距地1.3M暗裝
22、。10,另可參見暖通設計設計說明及施工說明。空調處理機組:1,現場DDC控制,DDC控制器的通信協議應符合樓宇控制系統(tǒng)要求。2,根據回風溫度,實現空調送風機與排風機的變頻調速運行。設回風機時,根據機組新、回風混合點靜壓實現空調回風機的變頻調速運行。3,盤管回水管設具備冷、熱模式轉換的動態(tài)平衡電動調節(jié)閥。根據回風溫度,調節(jié)冷、熱水流量。4,以上控制風機優(yōu)先,即:動態(tài)平衡電動調節(jié)閥處于常開狀態(tài),僅當風機轉速達到下限值時,進行調節(jié)。5,根據回風相對濕度,控制加濕器的工作狀態(tài)。6,根據回風與新風焰值比較,控制熱回收裝置的工作狀態(tài)。7,根據室內設計狀態(tài)焰值與新風焰值的比較,確定是否全新風運行,即:夏季,
23、新風焰值低于室內設計狀態(tài)給值時,全新風運行。新風焰值室內設計狀態(tài)焰值時,最小新風量運行。冬季,新風焰值高于室內設計狀態(tài)給值時,全新風運行。新風焰值0室內設計狀態(tài)焰值時,最小新風量運行。8,所有空氣過濾器及風機設壓差報警。9,新風進風閥與送風機連鎖。新風處理機組:1, 盤管回水管設具備冷、熱模式轉換的動態(tài)平衡電動調節(jié)閥。根據送風溫度,調節(jié)冷、熱水流量。2, 根據送風相對濕度,控制加濕器的工作狀態(tài)。3, 根據排風與新風的焰值比較,控制熱回收裝置的工作狀態(tài)。4, 表冷器設防凍開關,實現盤管的防凍控制,即:達到防凍控制溫度時,使動態(tài)平衡電動調節(jié)閥全開同時關閉風機與新風進風閥。5, 所有空氣過濾器及風機
24、設壓差報警。6, 新風進風閥與風機連鎖。熱回收交換器:1, 夏季一一熱回收交換器的新風及排風入口分別設置焰值傳感器,比較新風及排風焰值,新風焰值高于排風焰值時工作。否則,打開旁通。2, 冬季一一利用新風入口設置的焰值傳感器輸出的溫度信號,比較新風溫度及冬季室內設計溫度,前者低于后者時工作,否則,打開旁通。風機盤管:1, 風機盤管配有獨立溫控器,溫控器應具有冷、熱模式轉換功能。2, 風機盤管回水管設具有斷電復位功能的動態(tài)平衡電動兩通閥,風量由手動三速開關控制。冷卻塔(一)總體要求1、滿足循環(huán)冷卻水的最大散熱要求,熱力性能要求達到100%Z上。并有權威的檢驗證書。2、飄水損失:不大于總循環(huán)水量的0
25、.001%,并有權威機構檢驗證書;要求制造商具有ISO9000系列認證。3、風載荷:1.2KN/W,能承受十二級風時的載荷4、地震載荷:地震烈度按叩度設計構造。4、可接受的產品為進口或國內合資品牌產品,但技術標準必須滿足本技術規(guī)范的要求。5、設備選型應滿足現場實際安裝條件。(二)產品制造需符合以下標準和規(guī)范:冷卻水塔及其相輔助設備之材料、制造、組焊、檢驗、測試與涂裝必須遵守下列有關法規(guī)或標準之最新版次的規(guī)定:GBJ102-87工業(yè)循環(huán)冷卻設計規(guī)范GB7190-87玻璃纖維增強塑料冷卻塔GB1033-86塑料比重試驗方法GB2046-80塑料燃燒性能試驗方法GB/T1040-92塑料拉伸性能試驗
26、方法NDGJ88-86卻塔淋水填料技術規(guī)定NDGJ89-89X業(yè)冷卻塔測試技術規(guī)定如有國外規(guī)范和法規(guī)與中國國標有抵觸,應遵循國家標準(三)產品要求1、塔體塔體結構支架:要求采用金屬框架結構,強度、剛性好,能平穩(wěn)承受冷卻塔運行時的各種荷載。所有金屬構件必須經過去除氧化層及油脂,并磷化防腐處理,外層再經過熱浸鋅處理。塔身外殼處理:塔身外殼為Z600以上鍍鋅鋼或玻璃鋼材質,(金屬材料應考慮防雷措施)表面商標字跡清晰端正,有產品銘牌。塔芯填料:要求耐70c高溫、-50C低溫,不變形,抗紫外線、耐酸蝕,耐鹵蝕,阻燃性好,氧指數要求不小于33,達到國家B1級標準,壽命不小于15年。填料整體板型結構合理,風
27、阻系數小,氣流水流分布均勻,水損失低。重量輕,親水性能好。填料不應采用再生材料制作。且該填料要求必須采用先進的安裝方式以便于日后的清洗維護。集水槽:要求采用深水型集水槽,避免冷卻水泵開啟時,產生汽蝕。并有自動、手動補水裝置,以及溢水口和排污口。集水槽上部要求采用防飛濺措施,且附帶隔聲設施。冷卻塔為自帶集水盤型。冷卻塔出水口:要求采用出水濾網,出水濾網材質要求采用304不銹鋼。每一冷卻塔應由供貨商提供完整的產品,包括塔體結構、底盤、集水缸、框架、圍護、電動機、傳動裝置及風機、風扇網、配水系統(tǒng)、填料、安裝維修扶梯、塔體維修通道、檢修門等,應能滿足機組常年使用的要求。2、電機:概述:要求采用冷卻塔專
28、用電機廠生產的全封閉式電機,具有防水性能;采用皮帶傳動,皮帶選用進口防水三角帶。電動機額定負荷應合適于相應設備起動及滿負荷的需要,電動機在已知工況環(huán)境及現場條件下能連續(xù)額定運行,使用壽命15年以上基本結構:塔內全封閉三相異步電動機。防護等級IP55。絕緣耐溫等級F級品牌選用ABB或GESIEMENS技術要求:電動機應能滿足風機需要電動機輸出的轉速、轉矩、及其他機械要求。當電源的電壓與額定值的偏差不超過+10%-10以及電源的頻率與額定值的偏差不超過土2HZ時,輸出功率仍能維持額定值。在出線端標志字母順序與三相電源的電壓相序方向相同時,從軸伸出端視之,電動機應為順時針方向旋轉。電動機應具有可靠的
29、接地裝置,并應有指示接地的明顯標志。皮帶減速器采用皮帶減速器,減速器內應配置進口軸承,軸承使用壽命至少10萬小時減速機、傳動軸及馬達支撐架必須以型鋼為主體的一體鋼構,傳動軸及連軸器應設防護蓋裝置。優(yōu)質皮帶采用進口名牌產品。風機風機應采用高強度鋁合金機翼型葉片風機,風機翼尖與塔體內壁之間的問隙均勻,保證葉片與風筒不相碰。風機應為超低噪聲型冷卻塔專用風機,風機須經動平衡和靜平衡測試。風扇葉下加裝消聲導風罩,防止空氣逆流。風機及電機及傳動機構被風胴整個包裹,任何部分不能暴露在風胴之外。支撐及連接部件結構支架要求采用金屬框架結構,所有金屬結構件厚度必需經過除氧化層及油脂,并磷化防腐處理,外層再經過熱浸
30、鍍鋅處理。連接部件必須為優(yōu)質不銹鋼連接部件。底盆及集水缸:底盆及集水缸如為玻璃鋼,必須為達到國家B1難燃級標準材質,提供檢測報告。集水量必須保證系統(tǒng)正常運行。補水、溢水、排污裝置:冷卻塔應設自動和手動補水裝置,并帶有溢流及排污口;自動補水器采用不腐蝕浮球的遙控浮球閥,動作應嚴密靈活。配水系統(tǒng):采用先進、合理的布水方式,要求布水均勻、抗堵塞、清理維修方便。該設備能夠及時提供所需的備品備件、易損件。冷卻塔應由供貨商提供可靠、方便的塔內貫通式維修通道,以便進行塔體內部的維修、清理及填料更換,如塔頂無可靠的上人檢修平臺,應在塔頂部加設鋼制檢修平臺,以便于電機、風機、軸承等的維護及檢修工作。廳P設備名稱型號及規(guī)格單位數量1冷卻塔(方形橫流,低噪音型冷卻塔)1、冷卻水水量為420m3/h2、室外濕球溫度:26.9C3、進水溫度:37C4、出水溫度:32C5、電機功率:5.5KWX3臺4冷卻塔設備技術參數表注:1、單臺冷機運行流量為357m3/h,冷卻塔設計水量已放大。2、冷卻塔基礎土建專業(yè)只在屋頂預留反梁,冷卻塔需自配型鋼基礎。暖通主要設備材料表一一制冷站設備表設備名稱規(guī)格與性能數量單位承壓備注離心式冷水機組Q=1758kw(6/11C)額定工況COP>5.0,N<32
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 年會部門經理發(fā)言稿
- 測繪服務投標方案(技術標)
- 達英-35對未育女性人工流產術后子宮內膜的影響
- 工作標兵先進事跡材料(10篇)
- 初級會計實務-初級會計《初級會計實務》模擬試卷681
- 初級會計實務-《初級會計實務》模考試卷247
- 城市復雜環(huán)境低成本北斗-GNSS高精度單車定位技術研究
- 2024年中國熱處理行業(yè)深度分析、投資前景、趨勢預測報告(智研咨詢)
- 補陽還五湯聯合杵針治療腰椎術后殘留神經根癥狀的臨床療效觀察
- 二零二五年度廢棄包裝物處理及資源化利用合同3篇
- 醫(yī)院消防安全培訓課件
- 《00541語言學概論》自考復習題庫(含答案)
- 2025年機關工會個人工作計劃
- 江蘇省南京市、鹽城市2023-2024學年高三上學期期末調研測試+英語+ 含答案
- 2024護理不良事件分析
- 光伏項目的投資估算設計概算以及財務評價介紹
- 電力安全工作規(guī)程(完整版)
- 2024年湖南省公務員錄用考試《行測》試題及答案解析
- 借名買車的協議書范文范本
- 中國古代文學史 馬工程課件(下)21第九編晚清文學 緒論
- 2023年鐵嶺衛(wèi)生職業(yè)學院高職單招(語文)試題庫含答案解析
評論
0/150
提交評論