版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
PAGE
1
PAGE
37
ScientificandTechnicalWriting
Contents
ChapterOne:TypesandFormatsofScientificandTechnicalWriting
SectionOne:TypesofScientificandTechnicalWriting(P2)
SectionTwo:FormatsofScientificandTechnicalWriting(P3)
ChapterTwo:TheProcessofScientificandTechnicalWriting
SectionOne:WritingApproach(P20)
SectionTwo:WritingProcess(P20)
ChapterThree:TipsforScientificandTechnicalWriting
SectionOne:TheCharacteristicsofScientificandTechnicalWriting(P32)
SectionTwo:TheOrganizationandDevelopmentofScientificandTechnical
Writing(P35)
ChapterFour:OralCommunication
SectionOne:MeetingPeople(P42)
SectionTwo:AttendingLectures(P43)
SectionThree:PresentationofResearchingInformation(P44)
ChapterOne:TypesandFormatsofScientificandTechnicalWriting
SectionOne:TypesofScientificandTechnicalWriting
MemoReports
Thememoreportisthemostcommonandprevalenttypeoftechnicalwritingfoundinindustrytoday.Itisaninformalreportandisstrictlyaninternaltypeofcommunication.Thekeytowritingeffectivememoreportsisbrevityandsimplicity.
FormalReports
Formalreportsarethecomprehensivedocumentationofmajortechnicalprojects.Bythenatureoftheirscopeandimportance,theytendtobelonganddetailed.Theactualscopeandcomplexityofanyparticularformalreportwilldependonthesubstanceofthereportitself.Mostformalreportsareoutsidereportsfromonecompanytoanother.Theycovermanyofthesamesubjectsasinsidememo-reports.Theformatvariesgreatly,dependingonthecompany’sstandardsandthenatureofthereport.
Proposals
Aproposalisasellingdocumentthatadvocatesthepurchaseofacompany’sproductsorservices.Itcanalsocomefromwithinasinglecompanyandadvocatethepurchaseofequipmentorhiringofadditionalpersonnel.Proposalsfromonecompanytoanothergenerallytendtobelengthyandcomplex.Proposalsthataregeneratedwithinasinglecompanytendtobebriefandsimple.Ineithercase,thereaderswillbeprimarilymanagerial.
Ifaproposalissolicited,itwillbeamirrorofanRFP(requestforproposal).Iftheproposalisunsolicited,itwillreflectthethinkingofthefirmseekingthecontractanditsestimateofwhatthereceivingcompanyrequires.
Manuals
Technicalmanualisadocumentationofaprocessormechanismoracombinationofthetwo.Throughdocumentationinthemanual,theelementsofaprocessormechanismaredefinedanddescribed,andinstructionsforitsuseareprovided.Thisusecancoversuchthingsasoperation,maintenance,servicing,andrepair.
JournalArticles
Fewaccomplishmentswillenhanceyourprofessionalstandingasmuchasbeingpublished.Whenyoupublishanarticle,ittellsyourprofessionalcolleaguesnotonlythatyouhavesomethingoriginalanduniquetocontributetoyourfield,butalsothatitisimportantenoughtobepublished.Contrarytopopularopinion,thetradejournalsarealwaysinterestedinfreshnewprofessionalarticles.Newideas,newproducts,newfindings,andexperimentsarethelifebloodofthetradepublishingbusiness.Itisthroughtheprofessionalandtradejournalsthattheprofessional,scientific,andacademiccommunitiescommunicatewithoneanother.
Thekeytoagoodjournalarticleisitsorganizationandclearpurpose.Outlininganarticleiscrucialtoitsgettingpublished.Thesubjectmustbeinaccordancewiththejournal’sparticularsubjectmatter,andthearticlemustpublishnewandinterestinginformationforitsreaders.Mostprofessionalandtradejournalshavewrittenguidelinesfortheirpublishingexpectations.Eachisuniqueinitspersonalityandstyle.
SectionTwo:FormatsofScientificandTechnicalWriting
1.MemoReports
PartsofMemoReports
Thetypicalmemoreportismadeupofthefollowingparts.
1.Headinginformation:
Headinginformationgivesthereaderthewritingsolution.Itspecificallytellsyourreaderthedateofthememoreport.Thisdateiscrucialtokeepingfiles.Ittellstowhomthememoisbeingwritten.Thisisusuallyasinglereader,butitalsomaybeagrouporanumberofindividuals.Theheadinginformationtellsthereaderwhowrotethememoreport.Thisagaincanbeeitherasinglepersonoragroup.Andfinally,headinginformationgivesthesubjectofthereport.
Headinginformationismadeupoffourbasicheadings,asfollows:
Date:(thedateofthememoreport)
To:(towhomthememowaswritten)
From:(whowrotethememo)
Subject:(thesubjectofthereport)
Theorderofthesetopicsisnotimportant,butallfourtopicsmustbeincludedintheheading.
Sometimesthereceiverofthememoreportisasingleperson,butphotocopiesaredistributedtootherswhoarelessdirectlyinvolvedinthematterathand.Thenamesofindividualswhoreceivecopiesarenotedintheheadinginformationaftertheabbreviation“cc:”(for“carboncopy”).
2.Purposestatement
Thestatementofpurposetellsthereaderwhythememowaswritten.Effectivestatementsofpurposearealwaysdirectandconcise.Theysacrificesubtletyfordirectness.
3.Backgroundstatement:
Abackgroundstatementshouldbebriefandconcise.Itprovidesthereaderwithanoverviewoftheeventsandcircumstancesthathaveledtothereport.Italsoallowsarecapandreminderforthereaderwhoreferstothememoreportatalaterdate.
4.Discussion:
Thediscussionisanobjectiveandfactualwrittencommunicationoftechnicalmessage.Itisadetailedandcompletemessageaboutthesubject.Thediscussioniswherethebasicorganizationalpatternandoutlineofideasareputintowrittenform.
5.Conclusion:
Conclusionsarethereasonsorcausesoftechnicalconditionsandsituations.Theseareyourfindingsorresultsaboutwhateveritisthatyouarewriting.
6.Recommendations:
Recommendationsarethesuggestionsbasedontheconclusions,andprofessionalopinionsaboutwhatshouldbedone.
2)Typesofmemoreports:
1.Feasibilityreports:
Feasibilityreportistoshowwhetherundertakingacertainprojectorpathofactionwillhavesuccessorfailure.Thelikelihoodofsuccessmustbeweighedagainsttheoddsforfailure.
Thereportpresentstheevidenceforthatsetofoddsfororagainstthesuccessofthereport.
Thestructureofthistypeofreportisasfollows:
Memo-reportheadings
Purpose
Background
___Proceduresandmethods
___Alternatives
Discussion
Conclusions
Recommendations
SampleFeasibilityReport:
Date:_______________
To:________________
From:________________
Subject:Shouldmotor-drivenlinearactuatorsreplacedouble-acting
Hydrauliccylindersonpinchrollers?
Purpose:
Thepurposeofthisreportistostudythefeasibilityofhavingmotor-drivenlinearactuations(ball-screwstyle)replacethedouble-actinghydrauliccylindersonthepressure-heatedpinchrollersforthe24’’counter-toplaminator.Feasibilityisbasedoneconomicandwork-effectivenessfactors.
Background:
About22yearsago,AcmepurchasedtheOtto24”laminatorcurrentlybeingusedattheMelvilleplant.
Thismachineusesthreesetsofhydrauliccylinders(2perpinchroll)toexert800psiasthelaminatedtopexitsthegluerandentersthepressarea.
Dependingonwhatsizethicknesstheoveralltopwillmeasure(1/4”,3/8”,1/2”,3/4”),youmustmanuallyadjusttheclevisendofthesecylinders.
Thisresultsinaset-uptimeofabout90minutes.Operatorcontrolsforthepinchrollersare“full-extend”or“full-extract”withnomiddlesetting.
Leaksinthisexistingsystemareaconstantproblem.Thepetroleumbasedoilattacksthegluethatholdsthelaminatetothebasewood.
Discussion:
Currenttechnologyinlaminatingmachinesusesmotor-drivenball-screwactuatorsinplaceofhydrauliccylinders.Thesemotorsuseaclosed-loopfeedbacksystemthatallowsforPLC(programmablelogiccontroller)basedcontrol.Consequently,set-uptimedecreasesfrom90minutesto5minutes.Becausetheseactuatorsaremotordriven,wecancompletelyeliminatethehydraulicsystem.
Theestimatedcosttoremovetheexistinghydraulicsystemandinstallthenewmotor-drivenactuatorshasthefollowingbreakdown:
Motoractuators&controllers……….$265,500.00
Removal&installationlabor…………$93,300.00
PLCoperatortraining………………….$7,500.00
First-yearcost……….$366,300.00
The24”counter-toplaminatorcurrentlyproduces4.4millionofproductin2,000hoursofoperationataproductionrate-per-minuteof$35.67.Thisisbasedonusingthefigureof85minutesofsavedset-uptimeandanaverageof7.5set-upsperweekona50-weekproductionschedule.
Theprojectedincreasesinproductionareasfollows:
Annualset-ups:……375(507.5)
Totalminutessaved……………31,875(37585)
Increasedproduction……………….1,136,981.20
($35.6731,875)
Additionalset-upadjustmentfactor…………0.94
Adjustedincreasedproduction……$1,068,762.30
($1,136,9810.94)
Conclusions:
Atinvestmentof$366,300.00ofnewmotor-drivenactuatorswillincreaseproductionatarateof$1,068,762.30.Thisequatestoapaybackperiodof17.2weeks.Assumingbothsystemsrequirethesameamountofmaintenancetime,additionalsavingswillresultfromlessproductdamagefromhydraulicleaks(estimatedat$87,000.00).AnotheradditionalfeatureistheabilityoftheOttolaminatortorunshortorders(lessthan100pcs)becauseofreducedset-uptime.
Recommendations:
Themotor-drivenlinearactuatorsshouldbepurchasedandinstalledassoonaspossible.
2.Insideproposals:
Aninsideproposalisareportingdocumentthatstaysinsidethefirm.Itspurposeisto
persuadethereadertoalloworfollowaparticularplanorcourseofaction.
Thestructureofinsideproposalisasfollows:
Memo-reportheadings
Background
Proposal
Costbreakdown
Proposedschedule
SampleInsideProposal
Date:______________________
To:______________________
From:______________________
Subject:Hand-heldtachometersforfieldsalesengineers
Background:
Forthepastyearithasbecomeapparentthatourfieldsalesengineerswouldgreatlybenefitfromhavinghand-heldtachometerstomeasurerotationalshaftspeedandlinearlinespeed.
Overthepastyear,Ihavehadnofewerthan16instanceswhereIhavehadtorelyonacustomer’swordorhis“bestguess”aboutthespeedofamotor,conveyor,orothermechanicaldevice.Evennameplatedataarequestionable,especiallyonolderequipment,becauseofyearsofmachinemodifications.Inmostofthesecases,materialswerereturnedbecauseincorrectspeeddatawereusedtocalculategearboxandvariablefrequencydrivesizes.Asaresult,customerprojectswererequiredtobeheldupwhilecorrectspeedreadingscouldbetakenandthecorrectmaterialshipped.
Proposal:
Iproposethateachofthesixfieldsalesengineersbeissuedamodel#610electronichand-heldtachometerwithcarryingcase.
CostBreakdown:
Ifeachsalesengineeraverages16returns(Thisisaconservativeestimatebasedonexperience)becauseofspeedmiscalculations,thefieldwillgenerate96RGRs(ReturnGoodsRequests).WeknowfrominternalauditsthateachRGRispresentlyaveraging$45.00.Amodel#610tachometerlistsat$375.00each.Wewouldneedsixofthem.Considerthefollowingbreakdownincosting:
Sixmodal#610tachometers(6$375.00)………….$2,250.00
CostofRGRs(96$45.00)…………$4,320.00
Thisisaninitialsavingsoverthefirstyearafterpurchaseof$2,070:
$4,320.00$2,250.00……………….$2,070.00
SuggestedTimeFrame:
SinceallofthesalesengineerswillbeinforthecorporateofficemeetingduringthesecondweekofSeptember,thiswouldbeagoodtimetogiveeachsalesengineeratachometerandschedulethemforaone-hourtrainingsessionwiththetachometer.
3.Status/progressreports:
Thistypeisweekly,monthlyandquarterlyperiodicreport,allowingmanagementtostay
informedonstaffprogresswithongoingtechnicalworkandprojects.
Thestructureofthereporttendstobeabbreviated,asfollows:
Memo-reportheadings
Statusofprojects
SampleStatusReport
Date:____________________________
To:____________________________
From:____________________________
Subject:Statusreportforweekofx/x/19xx—
Plasticretainerfor#622bearing
R&DreceivedthefinalCADdrawings.Thecorporatelegaldepartmenthasfiledthepreliminarypaperworkforpatentprotection.Finalcostfortheextrusiondiesamountedto$125,000.00.ProductionshouldbegininearlyJanuary.
Hydro-sealfor#622bearing:
Earlytestsshowthattheethylenepropylenesealdevelopedseriousleakageproblemsatrotationalspeedover4000RPM.Additionaltestsarescheduledfornextweek.
Pump-Masterinnerrace:
Sixadditionalfieldreportsarrivedthisweek,bringingthetotalto88reports.ThesereportsareonthechromiumplatingonthePump-Masterinnerraceanditsflakingandblisteringathightemperature(100cto120c).Allthereportsarelimitedtothoseinnerraceswith2.00”boresorless.PlatingU.S.A.(oursubcontractor)hasbeennotifiedandbatchnumbershavebeensubmitted.
Newrollerbearing#1221:
ThetestinglabhasreportedthatafaultyhydraulicmeteronourSide-Thrusttesterresultedintheprematurerejectionofthe#1221rollerbearing.Designspecificationscallfor75lbsofsidethrustwithsafetyfactorofX2.Retestinghasalreadybegun.
4.Testreports:
Thistypeofreportisaninformalandinsidereportonaspecific,one-of-a-kindtestor
testingproblem.Thisisoftenadetailedaccountofthetestresultsforaparticularpartof
item.Oritcouldbeareportaboutaproblemwithtestingitselforsettingupatest
procedure.
Thestructureofthistypeofreportisasfollows:
Memo-reportheadings
Purposeorproblem
Conditions
Proceduresandmethods
Conclusions
Recommendations
SampleTestReport
Date:__________________________________
To:__________________________________
From:__________________________________
Subject:VariableFrequencyDriveComparisonTest
PurposeofTest:
Thistestcomparesthebreakdown(saturation)frequencyandcurrentoutputofthetopthreebrandsofvariablefrequencyelectronicdrives.Thecomparisonsareunderacontrolledenvironmentwithidenticallineandloadconditions.
Conditions:
AllthreedrivesusePWM(PulseWidthModulation)technologywithmicroprocessorfrontendsforprogrammingandsettingparameters.Allwereprogrammedfor400Hzmaximumfrequencywitha60Hzknee/voltagesetting.Alldrivesuseacommonlinepowerof460V,3-phase,and60Hz,with30Acurrent-limitingfuses.Alldriveshaveidenticalmotorloadsratedat15HP,1800RPM,460V,and3-phase.AllhaveNEMA7and9hazarders-locationmotorratingforClassI,Div.I,andGroupCandD.
Procedure:
Currentwasmeasuredwithaclamp-onACampmeteronthe0-30Ascalesetting,withreadingsontheincomingBphaseofeachdrive.Agroundingconductorwasconnectedtothemotorframeoneachchassisandbuildinggroundconductor.Eachelectronicdrivewasstartedat0Hzandincreasedin1HzincrementsuntiltheampmeterreadFLA(FullLoadAmperage).Inthistest,theFLAwas21A.Individualcurrentreadingswerealsomadeateachmotor’sdesignedmaximumfrequency(172Hz).
Conclusions:
BrandCprovidedthebestperformance,withamaximumfrequencyof206Hzandaminimumcurrentdrawof18-7Aatthedesignedmaximumfrequencyof175Hz.
Recommendations:
StandardizeonbrandCforall175Hzdesignapplicationsusingthe1800RPM,15HPmotor.
5.Tripreports:
Atripreportprovidesapermanentrecordofthetripforfuturereference.Itrecordsthe
actionstakenandaccomplishmentsduringthetrip.Theexperienceofoneemployeeonthe
tripbecomesavailableforotherpersonnelinthefuture.
Thestructureofatripreportisasfollows:
Memo-reportheadings
Purposeofthetrip
Conclusion
Actionstaken
Recommendations
SampleTripReport
Date:____________________________
To:____________________________
From:____________________________
Subject:AlbuquerqueVoTechCenter(A.V.C.)
PurposeoftheTrip:
InSeptember,JimVaughan,oneoftheA.V.C.instructors,toldusthatthefivehydraulicstudent-trainingstationshehadpurchasedinAugustofthisyearhaddevelopedleaks.Hetriedsimplytotightenthefittingsandgasketcovers,butthisdidnotstoptheleaks.Withnolocaltech-repintheAlbuquerquearea,Imadetheside-triptoAlbuquerqueonmywaytothePhoenixTrainingProductsshow.
Conclusions:
Allfivestudent-trainingstationshavecomponentsthatleakedatthepointwherethebrassfittingsthreadintothesub-basesandmanifolds.Onfurtherexamination,Ifoundthatthesefittingsweremadewithouttheuseofsomesortofpipe-threadcompound.FourofthefivetrainingstationswereleakingfluidatthePlexiglascoversonthefrontofthereservoirs.
ActionsTaken:
Iremovedallthefittingsoneachtrainingstationandused3/8-inchtapetosealthefittingsinthesub-basesandmanifolds.Pressuretestsshowedthatallleaksweresealedwiththisaction.
Idrainedeachreservoirandremovedthecovertofindthatinallcases,the1-inchgasketsusedtosealthereservoirwallandthePlexiglascoverhadtorntheboltholesthatruntotheoutsideedge.Ihand-cutnewcovergasketsandhand-punchedtheboltholes.Afterinstallingthegasketsandcovers,Irefilledthereservoirsandtestedthemundernormaloperatingpressure.Allleakswerestopped.
Recommendations:
Teflontapemaynotbetheoptimumsolution.Wemustusepipe-threadjointcompound
onfuturetraining-stationmanufacturing.Wemustalsoconsiderthethermalexpansion
betweenthebrassfittingsandthesteelsub-bases.
WemustpurchaseaholepunchofcorrectsizeformakingtheboltholesinthePlexiglas
Covergasket.Asanalternative,wecouldpossiblyuseadrillpressandjigtopre-drilltheseholeswithaccuracyandcare.
2.FormalReport
Becauseformalreportsaremorecomplexthanmemo-reports,theyrequireamoreformallystructuredformat.Thebasicelementsofaformalreportareasfollows:
Titlepage
Tableofcontents
Executivesummary
Body(includingallheadings)
Conclusions
Recommendations
References
Bibliography
Appendixes
Glossary
Index
Notallformalreportswillrequireeveryelement.Insomecases,variouspartsofthese
elementswillbecomeseparatepartsofthereportandwillstandalone.
1)TitlePage
Thetitlepagecanbearrangedinanumberofways,butthebasicelementsmustbethere.The
basictitleelementsareasfollows:
Thefulltitleofthereport
Thenameofthewriter
Thewriter’scompany
Thepersonorcompanyreceivingthereport
Thedateofthereport
2)TableofContents
Thetableofcontentsallowsyourreadertofindthemajorelementsofyourreporteasily.The
tableitselfislocatedatthefrontofthereportjustafterthetitlepage.Itisadirectreflection
ofyouroutlineandisderiveddirectlyfromit.Thetableofcontentscontainsallprimaryand
secondaryheadingsandtopicsastheyappearedinyouroutline.
Tablesandfiguresarealsocontainedinthetableofcontentsbutarelistedseparatelyafterthe
topicheadings.Theyarestillpartofthecontentsofthereport,buttomakethetableof
contentsclearer.
3)ExecutiveSummary
Inrecentyears,theexecutivesummaryhasbecomethemostcommonvehicleinreportstogiveacondensedoverviewofthereportforexecutiveandmanagerialaudience.Itshouldbelimitedtoamaximumofoneortwopages.Theprimarypurposeoftheexecutivesummaryistocondensethereportforthosewhodonothaveeitherthetechnicalknowledgeorthetimetoreadtheentirereport.
Theinformationintheexecutivesummaryislimitedtothebackground,findings,andconclusions,alongwiththerecommendationsofthereport.Thissummaryshouldalwaysbeplaceddirectlyafterthetableofcontents.Theexecutivesummaryshouldclearlysummarizeandcondensethefollowinginformation:
Backgroundofopportunityorproblem
Profitand/orcostimplications
Findingsand/orconclusions
Recommendations
4)MainbodyorDiscussion
Themainbodyisthecompleteaccountofwhatyouarewritingabout.Themainbodyis
oftencalledadiscussionbecause,asinanoraldiscussion,youwillconvertyourstructured
ideasinoutlineformtoflowing,conversationalprose.
Themainbodyofthereportcoversallthetechnicaldetailsofthesubjectaswellasallthe
administrativeresults.Thispartmaycontainanyoneorallthethreeelements:definition,
descriptionandinstruction.Theorganizationofthereportmustreflectabsolutelyandin
detailtheoutlinepreviouslyestablished.
5)Conclusions
Theconclusionssectionputstheresultsandfindingsofthediscussioninoneplaceforthe
reader.Theemphasishereisonwhathavebeenfoundinlightofthepurposeofthereport
anditsimplications.
6)Recommendations
Therecommendationssectionistheopinionbasedontheevidenceandtheexpertiseasa
professional.Itiswhatthewriterfeelisthebestcourseofactionbasedonthereport’s
conclusionsandfindings.
7)References
SampleformalReport
TitlePage:
High-Frequency400HzACasanAlternativetoStandard
Low-Frequency60HzACforFluorescentLightingLoads
By
L.A.Mielcarz
TechnicalDesignConsultant
Preparedfor
XYZDevelopmentCorporation
Chicago,Illinois
July1,19XX:
TableofContents:
ExecutiveSummary…………………1
DetailedDiscussion…………….…..3
PurposeofStudy………………….3
Background………3
LightingLoad…….3
BallastHeat……….4
FixtureCostComparison…………….4
FixtureMaintenanceComparison……4
GeneratorCostsandSpecifications….4
InstallationCosts…….4
CostAnalysisofBothSystems……...4
Conclusions………..4
Recommendations…………………4
Appendixes…………6
LightingFixtureEnergyCostTable…….6
BallastHeatTable……….6
FixtureCostTable……….6
FixtureMaintenanceTable………………6
Bibliography…………7
Glossary……………..7
Index………………..7
ExecutiveSummary:
Thepurposeofthisreportistodeterminethefeasibilityofaself-generated,high-
frequencyACpowersourceforfluorescentlighting.
Recenttechnologyinhigh-frequencygenerationforfluorescentlightingloadshas
provensuccessfulinvariousEuropeancountries.Suchinstallationscanreduceair-
conditioning(cooling)loads,initialcostoflightingfixtures,fixturemaintenance,and
generalenergyconsumption.Thisreportexaminestheapplicationofthistechnology
inthenewbandandofficecomplexinNorthPhoenix.
LightingLoadAtotalof7,472fixtureswithenergy-savinglampswillcausea
totalloadof2,830,900kwhr.Thiswillcost$184,008.00.
BallastHeatTheheatgeneratedbythe13,852ballastsinthebuildingwilltotal
620,157Btu.Annualcosttoremovethisheatwiththeair-conditioningsystemis
projectedat$29,575.00.
FixtureCostComparisonStandardfixturecoststotal$314,766.00.High-frequency
coststotal$297,212.00.Thedifferencebetweenthetwois$17,554.00.
FixtureMaintenanceComparisonEstimatedstandardfixturemaintenancewill
cost$16,812.00annually.Thedifferencebetweenthetwois$13,076.00.
GeneratorCostsA1,500kwthree-phasegenerator(alternator)hasan
initialcostof$646,580.00.Itsprojectedannualenergyconsumptionis
$158,600.00.Theestimateannualmaintenancecostonthisgeneratoris
$12,500.00.
InstallationCostInstallationcostforthegeneratorandmainswitch-gear
onlyisestimatedat$132,500.00.Dedicatedwirewaysandlightingpanels
forthehigh-frequencydistributionsystemareestimatedat$283,750.00.
CostAnalysisofBothSystemsAhigh-frequencyself-generatedsystem
willcostmorethanastandardsystem.Thedifferenceinsystemcostis
$1,045,276.00.Theannualenergyandlaborsavingswillbe$55,559.00
basedonpresentenergyandlaborcosts.
ConclusionsPaybackisprojectedtobe18.8years.Thepaybackisfigured
intermsofenergysavings,reducedlightingmaintenance,andreduced
fixturecosts.
RecommendationsBasedonaprojectedpropertyholdingtimeofeightyears,
thepaybackperiodisfartoogreatandwouldincurinvestmentloss.Use
traditionalwiringmethodsandpublicpowerforallenergyusesinthebuilding.
Discussion(Body):
PurposeofStudy
Thepurposeofthisreportistodeterminewhetheraself-generated,high-frequency
ACpowersource(generator/alternator)canbeusedattheXYZDevelopment
complexinNorthPhoenix.Thisreportwilldeterminewhethertheself-generated
systemcanbeeconomicallyinstalled,operatedandmaintained.Itwilldetermine
whetherthesystemcanprovidesufficientenergysavingstopayforitselfovera
feasibleperiod,basedonaprojectedeight-yearpropertyownership.
Background
IncorrespondencedatedJanuaryX,19XX,JaneReynolds,ManagerandCEO
ofXYZDevelopmentCorporation,mentionedherobservationsduringarecent
triptoEuropeoflightinggenerationatseveralmajorhotels.Thehotelswereusing
self-generated,high-frequency(400Hz)ACpowersupplies.
Thesesuppliespoweredthefluorescentlightingloadsinthehotelsandinadjacent
buildings.Themainpurposeforsuchelectricaldistributionistheabilitytoignite
fluorescentlampswithouttheuseoftraditionaliron-coreandcoilballasts.By
eliminatingtheballasts,thesystemalsoeliminatestheheatgivenoffbytheballasts.
Thisresultsinreducingtheoverallcoolingsystemload,initialfixturecost,ballast
maintenance,andreplacementcostofballasts.
Thequestionremainswhetheritisfeasibletousethisdedicatedsystemofpower
generationforfluorescentlightingintheproposed18-story,720,000sq.ft.bandand
officecomplexinNorthPhoenix.Ifsuchasystemisinstalled,itmustbedoneinthe
earlyst
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- Unit 1 Making friends PartA(教學實錄)-2024-2025學年人教PEP版(2024)英語三年級上冊
- 2024年度重慶市與四川省農(nóng)產(chǎn)品供應(yīng)鏈融資合同2篇
- 2024年度區(qū)塊鏈技術(shù)應(yīng)用部分股權(quán)轉(zhuǎn)讓與信息安全合同3篇
- 委托加工鋼材協(xié)議
- 2024年旅游景區(qū)安全員聘用及應(yīng)急預(yù)案制定合同2篇
- 2024年度藝術(shù)展覽合同范本與演出場地租賃協(xié)議2篇
- 門市房屋租賃合同
- 個人租賃商鋪協(xié)議書
- 11 小水滴的訴說(教學實錄)2023-2024學年統(tǒng)編版道德與法治二年級下冊
- 2024年中國極速汽油機油市場調(diào)查研究報告
- (高清版)WS∕T 389-2024 醫(yī)學X線檢查操作規(guī)程
- 2023六年級數(shù)學上冊 1 分數(shù)乘法《小數(shù)乘分數(shù)》說課稿 新人教版
- 店鋪(初級)營銷師認證考試題庫附有答案
- 專題03 地球上的水-備戰(zhàn)2025年高考《地理》真題題源解密(新高考)(解析版)
- 醬油項目可行性研究報告
- 公司年會安保方案(2篇)
- GB/T 8492-2024一般用途耐熱鋼及合金鑄件
- 員工快速招聘方案
- 現(xiàn)代通信技術(shù)導(dǎo)論智慧樹知到期末考試答案章節(jié)答案2024年北京科技大學
- 新融合大學英語(I)智慧樹知到期末考試答案章節(jié)答案2024年江西理工大學
- 中醫(yī)培訓課件:《耳穴基礎(chǔ)知識》
評論
0/150
提交評論