1、空調(diào)冷(熱)水系統(tǒng)的水力計(jì)算1 空調(diào)冷(熱)水水力計(jì)算的基本公式 (1-1) (1-2) (1-3) (1-4) (1-5) 式中 P-管網(wǎng)總阻力,(Pa) Pm-管網(wǎng)沿程阻力,(Pa) Pj-管網(wǎng)局部阻力,(Pa) 設(shè)備阻力-如制冷機(jī)組蒸發(fā)器及冷凝器、熱交換器、鍋爐、冷卻塔、風(fēng)機(jī)盤管、 新風(fēng)機(jī)組、空調(diào)機(jī)組等 R單位長(zhǎng)度直管段的摩擦阻力(又稱比摩阻),Pa/m; 摩擦阻力系數(shù),m; 管道配件的局部阻力系數(shù) 水的密度,kg/m3; v水的流速,m/s; k管內(nèi)表面的當(dāng)量絕對(duì)粗糙度,m;閉式循環(huán)水系統(tǒng):k=0.2mm;開(kāi)式循環(huán)水系 統(tǒng):k=0.5mm;冷卻水系統(tǒng):k=0.5mm。 d管道直徑,m。

2、 Re雷諾數(shù):附:一個(gè)大氣壓下水的密度2 空調(diào)計(jì)算管段冷(熱)水流量計(jì)算 (2-1)式中 計(jì)算管段的空調(diào)冷(熱)負(fù)荷,W; 供回水溫差,oC。(空調(diào)冷水供回水溫差不應(yīng)小于5 oC;空調(diào)熱水供回水 溫差,嚴(yán)寒和寒冷地區(qū)不宜小于15 oC,夏熱冬冷地區(qū)不宜小于10oC)確定計(jì)算管段的冷水量時(shí),可以根據(jù)管路所連接末端設(shè)備(如AHU、FCU等)的額定流量進(jìn)行計(jì)算(疊加)。但必須注意,當(dāng)總水量達(dá)到與系統(tǒng)總流量(水泵流量)相等時(shí),干管的水量不應(yīng)再增加。3 管徑的選擇及沿程阻力計(jì)算3.1 空調(diào)水系統(tǒng)單位長(zhǎng)度摩擦壓力損失(比摩阻)宜控制在100300Pa/m;最大不應(yīng)超過(guò)400Pa/m(熱水管道建議取低值)。

3、空調(diào)房間內(nèi)管道流速不宜超過(guò)表3-1的限值。 空調(diào)房間內(nèi)管道流速限值 表3-1管徑DN(mm)20253240507080100最大流速(m/s)0.80.81.01.01.21.51.52.0根據(jù)計(jì)算流量及3.1條的規(guī)定,查表3-1、3-2,選取管徑及R(比摩阻),Pa/m。 鋼管(水溫20 oC)摩擦阻力計(jì)算表 表3-1 表3-1中: G冷水流量,L/s; Rc閉式水系統(tǒng)(當(dāng)量絕對(duì)粗糙度k=0.2mm)的比摩阻,Pa/m; Ro開(kāi)式水系統(tǒng)(當(dāng)量絕對(duì)粗糙度k=0.5mm)的比摩阻,Pa/m。 鋼管(水溫40 oC)的摩擦阻力計(jì)算表 表3-2 鋼管(水溫50 oC)的摩擦阻力計(jì)算表 表3-3 鋼

4、管(水溫60 oC)的摩擦阻力計(jì)算表 表3-4 鋼管(水溫70 oC)的摩擦阻力計(jì)算表 表3-5 表3-25中: G熱水流量,kg/h; Pm-管網(wǎng)沿程阻力(Pa/m); v水的流速,m/s; 鋼管內(nèi)壁當(dāng)量絕對(duì)粗糙度取k=0.2mm??照{(diào)水系統(tǒng)用戶PP-R塑鋁穩(wěn)態(tài)管水力計(jì)算可以按下表來(lái)?。?空調(diào)水系統(tǒng)用戶PP-R塑鋁穩(wěn)態(tài)管水力計(jì)算表(水溫t=10,S3.2管系列表5-1 空調(diào)水系統(tǒng)用戶PP-R塑鋁穩(wěn)態(tài)管水力計(jì)算表(水溫t=10,S3.2管系列)i(Pa/m)不同公稱直徑dN(mm)時(shí)的流速v(m/d)和流量G(m3/s)2025324050637590110160200vGvGVGVGVGVG

5、VGVGVGVGvG200.120.070.140.140.160.250.190.450.220.800.251.480.282.330.313.790.366.400.4517.210.5231.40400.180.101.200.180.240.360.270.650.311.160.362.160.413.400.465.510.529.310.6625.040.7645.66600.220.130.250.230.290.450.340.810.391.450.452.690.514.230.576.860.6411.590.8231.170.9456.85800.250.150.2

6、90.270.340.520.400.940.461.690.533.140.594.940.668.020.7513.540.9536.421.1066.421000.290.170.330.300.390.590.451.060.511.910.603.540.675.570.759.050.8515.281.0841.091.2474.931200.320.190.370.330.430.650.491.170.572.100.663.910.746.150.839.990.9416.861.1945.341.3782.701400.340.200.400.360.470.710.541

7、.280.622.290.724.250.806.680.9010.851.0218.331.2949.281.4989.881600.370.220.430.390.500.760.581.370.662.460.774.570.867.180.9711.671.0919.701.3952.971.6096.611800.390.230.450.420.530.810.611.460.712.620.824.870.927.661.0312.431.1720.991.4856.451.71102.962000.420.250.480.440.570.860.651.550.752.770.8

8、75.150.978.101.0913.161.2322.221.5759.761.81108.992200.440.260.510.460.600.910.691.630.792.920.925.421.028.531.1513.861.3023.401.6562.921.91114.762400.460.270.530.490.620.950.721.710.833.060.965.691.078.941.2014.521.3624.521.7365.952.00120.282600.480.280.550.510.650.990.751.780.863.201.005.941.129.3

9、41.2515.171.4225.611.8068.862.09125.602800.500.290.580.530.681.030.781.860.903.331.046.181.169.721.3115.791.4826.651.8871.682.17130.733000.520.310.600.550.701.070.811.930.933.451.086.411.2110.091.3616.391.5427.671.9574.402.25135.703200.540.320.620.570.731.110.841.990.973.581.126.641.2510.451.4016.97

10、1.5928.652.0244.042.33140.523400.560.330.640.590.751.150.872.061.003.701.166.861.2910.801.4517.531.6529.602.0979.612.41145.203600.570.340.660.610.781.180.892.131.033.811.197.081.3311.141.5018.081.7030.532.1582.111.49149.763800.590.350.680.620.801.220.922.191.063.921.237.291.3711.471.5418.621.7531.44

11、2.2284.542.56154.204000.610.360.700.640.821.250.952.251.094.031.267.491.4111.791.5819.141.8032.322.2886.922.63158.534200.620.370.720.660.841.280.972.311.124.141.307.691.4512.101.6319.651.8233.192.3489.242.70162.774400.640.380.740.680.871.321.002.371.154.251.337.891.4812.411.6720.151.8934.032.4091.52

12、2.77166.924600.660.380.760.690.891.351.022.431.174.351.368.081.5212.711.7120.641.9434.862.4693.742.84170.974800.670.390.770.710.911.381.042.481.204.451.408.271.5613.011.7521.121.9835.672.5195.922.90174.955000.690.400.790.720.931.411.072.541.234.551.438.451.5913.301.7921.602.0336.472.5798.062.97178.8

13、65.3 修正系數(shù)(1) 當(dāng)水溫不同時(shí),應(yīng)按表5-1查得的i值乘以水溫修正系數(shù)k1。水溫修正系數(shù)剪標(biāo)5-2表5-2 水溫修正系數(shù)k1表水溫()51020304050556065水溫修正系數(shù)k11.03710.9430.8950.8560.8220.8080.7930.781 (2) 采用不同的管系列時(shí),由于管道的內(nèi)經(jīng)不同,所以,應(yīng)將由表5-1差的的i值乘以管系列修正系數(shù)k2。管系列修正系數(shù)見(jiàn)表5-3.表5-3 管系列修正系數(shù)k2管系列S5S4S3.2S2.5管系列修正系數(shù)k20.5730.73311.553 5.4 流速管道內(nèi)水的流速v(m/s),宜符合以下規(guī)定:公稱直徑dN32mm時(shí),v1.

14、5m/s;公稱直徑dN=40mm63mm時(shí),v2.0m/s;公稱直徑dN63mm時(shí),v3.0m/s。 4 局部阻力 4.1常用管道配件的局部阻力系數(shù),可由表4-1和表4-2查出。 常用管道配件的局部阻力系數(shù) 表4-1 三通的局部阻力系數(shù) 表4-2 電動(dòng)調(diào)節(jié)閥的阻力損失: (4-1)式中 4.2 根據(jù)表4-1、4-2及公式1-3計(jì)算局部阻力。4.3 空調(diào)水系統(tǒng)在估算時(shí),局部阻力約為直管總摩擦阻力的0.20.5,管路長(zhǎng)度較大時(shí)取下限值,長(zhǎng)度較小時(shí)取上限值。5 部分設(shè)備壓力損失的參考值各種設(shè)備的壓力損失,因設(shè)備型號(hào)和運(yùn)行條件、工況等的不同而有很大差異,其值通常應(yīng)由制造商提供。當(dāng)缺乏這方面的數(shù)據(jù)時(shí),可按下表進(jìn)行估算。 表-1 部分設(shè)備的壓力損失值設(shè)備名稱壓力損失(kPa)備注設(shè)備名稱壓力損失(kPa)備注離心式冷水機(jī)組吸收式冷水機(jī)組 蒸發(fā)器3080 蒸發(fā)器40100 冷凝器5080 冷凝器50140螺桿式冷水機(jī)組熱交換器2050 蒸發(fā)器風(fēng)機(jī)盤管機(jī)組1020隨機(jī)組容量的增大而增大 冷凝器冷熱水盤管2050水流速度:v=0.81.5m/s自動(dòng)控制調(diào)節(jié)閥3050冷卻塔2080 6 四管制及

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論