BRITISHSTANDARD
Compressedair—
Part8:Testmethodsforsolidparticlecontentbymassconcentration
ICS71.100.20
NOCOPYINGWITHOUTBSIPERMISSIONEXCEPTASPERMITTEDBYCOPYRIGHTLAW
BSISO
8573-8:2004
Britishstandards
BSISO8573-8:2004
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
Nationalforeword
ThisBritishStandardreproducesverbatimISO8573-8:2004andimplementsitastheUKnationalstandard.
TheUKparticipationinitspreparationwasentrustedtoTechnicalCommitteeMCE/8,Compressors,pneumatictools,pneumaticmachinesandvacuum
technology,whichhastheresponsibilityto:
—aidenquirerstounderstandthetext;
—presenttotheresponsibleinternational/Europeancommitteeany
enquiriesontheinterpretation,orproposalsforchange,andkeepthe
UKinterestsinformed;
—monitorrelatedinternationalandEuropeandevelopmentsandpromulgatethemintheUK.
Alistoforganizationsrepresentedonthiscommitteecanbeobtainedonrequesttoitssecretary.
Cross-references
TheBritishStandardswhichimplementinternationalpublicationsreferredtointhisdocumentmaybefoundintheBSICatalogueunderthesectionentitled“InternationalStandardsCorrespondenceIndex”,orbyusingthe“Search”
facilityoftheBSIElectronicCatalogueorofBritishStandardsOnline.
Thispublicationdoesnotpurporttoincludeallthenecessaryprovisionsofacontract.Usersareresponsibleforitscorrectapplication.
CompliancewithaBritishStandarddoesnotofitselfconferimmunityfromlegalobligations.
Summaryofpages
Thisdocumentcomprisesafrontcover,aninsidefrontcover,theISOtitlepage,pagesiitoiv,pages1to8,aninsidebackcoverandabackcover.
TheBSIcopyrightnoticedisplayedinthisdocumentindicateswhenthedocumentwaslastissued.
ThisBritishStandardwas
publishedundertheauthorityoftheStandardsPolicyand
StrategyCommitteeon
17June2004
?BSI17June2004
ISBN0580439607
Amendmentsissuedsincepublication
Amd.No.
Date
Comments
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
INTERNATIONAL
STANDARD
ISO
8573-8
Firstedition2004-02-01
Compressedair—
Part8:
Testmethodsforsolidparticlecontentbymassconcentration
Aircomprimé—
Partie8:Méthodesd'essaipourladéterminationdelateneurenparticulessolidesparconcentrationmassique
ReferencenumberISO8573-8:2004(E)
ii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
iii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
Page
Contents
Foreword iv
1Scope
1
2Normativereferences
1
3Termsanddefinitions
1
4Unitsandsymbols
2
5Selectionofmethods
2
6Samplingtechniques
2
7Measurementmethods
3
8Evaluationoftestresults
6
9Uncertainty
6
10Testreport
7
AnnexA(informative)Sampletestreport
8
iv
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
Foreword
ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies
(ISOmemberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISO
technicalcommittees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeen
establishedhastherighttoberepresentedonthatcommittee.Internationalorganizations,governmentaland
non-governmental,inliaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththe
InternationalElectrotechnicalCommission(IEC)onallmattersofelectrotechnicalstandardization.
InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part2.
ThemaintaskoftechnicalcommitteesistoprepareInternationalStandards.DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting.PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote.
Attentionisdrawntothepossibilitythatsomeoftheelementsofthisdocumentmaybethesubjectofpatentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.
ISO8573-8waspreparedbyTechnicalCommitteeISO/TC118,Compressors,pneumatictoolsandpneumaticmachines,SubcommitteeSC4,Qualityofcompressedair.
ISO8573consistsofthefollowingparts,underthegeneraltitleCompressedair:
—Part1:Contaminantsandpurityclasses
—Part2:Testmethodsforaerosoloilcontent
—Part3:Testmethodsformeasurementofhumidity
—Part4:Testmethodsforsolidparticlecontent
—Part5:Testmethodsforoilvapourandorganicsolventcontent
—Part6:Testmethodsforgaseouscontaminantcontent
—Part7:Testmethodsforviablemicrobiologicalcontaminantcontent
—Part8:Testmethodsforsolidparticlecontentbymassconcentration
—Part9:Testmethodsforliquidwatercontent
Part2isunderrevision.
1
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
Compressedair—
Part8:
Testmethodsforsolidparticlecontentbymassconcentration
1Scope
ThispartofISO8573specifiestestmethodsfordeterminingthesolidparticlemassconcentrationincompressedair,expressedasthemassofsolidparticleswithmaximumparticlesizelimits.Thelimitationsofthemethodsarealsogiven.Oneofaseriesofstandardsaimedatharmonizingaircontaminationmeasurements,itidentifiessamplingtechniquesandalsogivesrequirementsforevaluation,uncertaintyconsiderationsandreportingfortheairpurityparametersolidparticlesbymassconcentration.ThetestmethodsaresuitablefordeterminingpurityclassesinaccordancewithISO8573-1.(ParticlecontentbasedoncountingparticlesisdealtwithinISO8573-4.)
2Normativereferences
Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.
ISO1219-1,Fluidpowersystemsandcomponents—Graphicsymbolsandcircuitdiagrams—Part1:Graphicsymbols
ISO3857-1,Compressors,pneumatictoolsandmachines—Vocabulary—Part1:General
ISO5598,Fluidpowersystemsandcomponents—Vocabulary
ISO8573-1,Compressedair—Part1:Contaminantsandpurityclasses
ISO8573-2,Compressedair—Part2:Testmethodsforaerosoloilcontent
ISO8573-4,Compressedair—Part4:Testmethodsforsolidparticlecontent
3Termsanddefinitions
Forthepurposesofthisdocument,thetermsanddefinitionsgiveninISO3857-1,ISO5598,ISO8573-1andISO8573-4apply.
2
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
4Unitsandsymbols
ForthepurposesofthispartofISO8573,thefollowing,includingnon-SI-preferred,unitsareused:
—1bar=100000Pa;
—1l(litre)=0,001m3;
—bar(a),usedforexpressingabsolutepressure;
—bar(e),usedforexpressingeffectivepressure.
ForthegraphicsymbolsusedinFigure1,seeISO1219-1.
5Selectionofmethods
Thegravimetricmethodtobeusedissuitableformassconcentrationmeasurement,however,wherewaterandoilispresentinthecompressedair,itshallbereducedtoaminimum.
AsuitablemethodforsolidparticlediametermeasurementmaybeselectedfromthosegiveninTable1.
Table1—Solidparticlediametermeasurementmethods
Typeofmethod
Maximumsolidparticlediameter
d
μm
Liquidwaterandoilcontaminant
mg/m3
Microscopemethod
d>0,5
<20
Particlesizermethod
0,1<d<40
Notadmitted
6Samplingtechniques
Thesamplingshallbemadeatorneartheactualpressureandataconstantflowrate.
Thechoiceofsamplingmethodwilldependupontheactuallevelofcontaminationandthecompressedairflowinthecompressedairsystem.Forsamplingmethods,seeISO8573-2andISO8573-4.
Forpartialflowsampling,itshouldbenotedthat,wherelargeparticlesizesareinvolved,theeffectsofgravitycouldintroducesamplingerrors.
Compressedairsamplesmayberoutedbackintothemainpipeorventtotheatmosphereaftermeasurement.Thevalueofairsampleparameters(pressure,temperature,airvelocity,etc.)shallbewithintherangesspecifiedbythetestequipmentmanufacturer.MethodB1usesfullflowsamplingfromthemainpipeflowbymeansofaY-piece.
3
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
7Measurementmethods
7.1General
Thetestequipmentandinstrumentsshallbeingoodworkingorder.Considerationshallbegiventothecalibrationrequirementsofthemeasurementequipmentusedasgivenintheapplicableinstructions.
Theindicatedmethodsmaybeusedatanypointinacompressedairsystemusingportableinstrumentswhereconditionsofmeasurementaresatisfiedandavailableconnectorsandshut-offvalvesexistforconnectiontothecompressedairsystem.
Inordertoguaranteetherequiredaccuracyofdeterminationofsolidparticlecontentbythegravimetricmethod,thetotalcontentofwaterandoilaerosolsinthecompressedairsamplingshallbelessthan20mg/m3forsamplingMethodAandlessthan5mg/m3forsamplingMethodsB1andB2.
Referenceshouldbemadetothemeasurementequipmentmanufacturerinrespectoftheapplicabilityoftheequipment.
Thegravimetricmethoddealswiththeseparationandtheweighingofsolidparticlesthatarepresentinacompressedairsample.Theinfluenceoftemperature,pressure,humidityandothercontaminantsofcompressedairshallbetakenintoconsideration.
7.2Testequipment
7.2.1General
Airflowispassedthroughthetestequipmentviasuitablein-linevalveswhichhavebeenpreviouslycheckedtoensuretheydonotcontributetothelevelofcontaminationalreadypresent.
ThegeneralarrangementofthetestequipmentforthegravimetricmethodshallbeinaccordancewithFigure1.
NOTEThenumbersgivenbetweenparenthesesinthesubclausetitlesrefertothenumberingoftheelementsin
Figure1.
Forsymbols,seeISO1219-1.
Key
1samplingpoint
2shut-offvalve
3heater(ifrequired)
4membraneholder
5pressuregauge
6
7
8
910
thermometer
flowcontrolvalve
airflowmeter
shut-offvalve
dischargeoutlet
Figure1—Circuitdiagramoftestequipmentforgravimetricmethod
4
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
7.2.2Membraneholder(4)
Themembraneshallbemanufacturedfromhydrophobichigh-efficiencymaterial.
NOTEForadescriptionofatypicalmembraneanditsholder,seeISO8573-2.
7.2.3Flowcontrolvalve(7)
Inordertoadjusttheflowaccurately,useavalvewithfineadjustment.
7.2.4Pressuregauge(5)
Thepressurevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementofthepressureshallbebetterthan±2%ofreading.
7.2.5Thermometer(6)
Thetemperaturevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementofthetemperatureshallbebetterthan±1°C.
7.2.6Airflowmeter(8)
Theflowratevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementoftheflowrateshallbebetterthan±5%.
7.2.7Pipes,connectors,shut-offvalves(2and9)
Therequirementsforpipes,connectorsandshut-offvalvesshallbeaccordingtoISO8573-2.
7.2.8Heater(3)
Theheatermaybeusedtodecreasethelevelofliquidwaterandoilcontaminantcontentinthecompressedairsampletothevaluespecifiedin7.1.Reducingtheamountofliquidwaterandoilcontentbyheatingand/orthereductionofthepressureofthecompressedairshallnothaveaninfluenceonsolidparticlecontentinthecompressedairsample.
7.3Testprocedure
7.3.1Preparationformeasuring
TheproceduresforpreparationformeasuringshallbeinaccordancewithISO8573-2.Theweightofthedrymembraneshallbedeterminedbeforethesampleistaken.
7.3.2Durationoftest
Theoptimumdurationofthecompressedairsamplingmaybedeterminedafterthefirstproofmeasurementtodeterminethetentativesolidparticleconcentration.
Approximatedurationoftest,t,inminutescanalsobedeterminedbythefollowinginequality:
<t<
mmin
cplimq
m
max
cplimq
(1)
5
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
where
mministheminimumrequiredamountofsolidparticlecontentonthemembrane,inmilligrams;
mmaxisthemaximumpermittedamountofsolidparticlecontentonthemembrane,inmilligrams;
Cplimistheassumedormaximumpermittedamountofsolidparticlecontentinthecompressedair,inmilligramspercubicmetre;
qisthecompressedairdischargethroughthemembrane,incubicmetresperminute.
Themassofsolidparticlescollectedonthemembraneshallbeinrange1mg<m<5mgon1cm2ofthemembranesurface.
7.3.3Measurementofsolidparticlemassconcentration
Ifliquidwaterandoilcontaminantsareabsentinthecompressedairflow,thesolidparticlemassconcentrationforeachsampleisdeterminedasadifferencebetweenmassesofthetestmembranebeforeandafterairsampling,dividedbythetotalvolumeofairpassedthroughthemembrane.Afterairsamplingandbeforeweighing,thetestmembraneshouldbeplacedinadesiccatoroverasuitabledesiccant,e.g.silicagel,for10-15minoruntilthemassofmembraneisstable.
Ifthereareliquidwaterandoilcontaminantsinthecompressedairflow,theyshallberemovedafterairsamplingandbeforeweighingofthetestmembrane.Forthispurpose,thetestmembraneshallbeplacedinthedesiccatoroversulphuricacidfor2h.Then,thetestmembraneiscarriedinthechemicalfunnelontheconicalwall(thefiltrateisoverthemembrane),pressedtotheconicwallwiththeglassstickandtreatedseveraltimesbysmallportionsofasuitablesolventoftotalvolume10-15mlfordissolvingandremovingoftheoil.Afterthat,thetestmembraneshallbemaintainedfor2-3minatatemperatureof20-30°Candthenweighed.
Othermethodsforremovalofwaterandoilfromthetestmembranearepermittediftheyhavenoinfluenceonsolidparticlecontentofthetestmembraneaftersamplingthecompressedair.
Themaximumuncertaintyofmeasurementofmassshallbebetterthan±2%.
7.4Calculationofresults
Itisnecessarytoensurethatresultsarestable,repeatableandpresentedinaformthatshowsthattheyareso.Thesolidparticlemassconcentrationcpninmg/m3foreachmeasurementshallbedeterminedbytheformula:
pn
c=
mn?m0
qntn
(2)
where
m0isthemassoftestmembranebeforesampling,inmilligrams;
mnisthemassoftestmembraneaftersampling,inmilligrams;
qnistheflowrateofsamplingairthroughthemembrane,incubicmetresperminute;
tnisthesamplingtime,inminutes.
7.5Determinationofmaximumdiameterofsolidparticles
ThemeasurementmethodsofmaximumdiameterofsolidparticlesidentifiedinTable1shallbecarriedoutinaccordancewithISO8573-4.
6
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
8Evaluationoftestresults
8.1Referenceconditions
Thereferenceconditionsforsolidparticlemassconcentrationvolumestatementsareasfollows:
—Airtemperature:20°C;
—Airpressure:1bar(a);
—Relativewatervapourpressure:0%.
8.2Influenceofhumidity
Themeasuredsolidparticlemassconcentrationshallberecalculatedtorefertothedryairvolumeasgivenbythepartialpressureoftheairatthesamplingpoint.Undernormalconditions,theeffectofhumidityonvolumecanbesmallandtherequirementtocalculateitseffectisusuallynotrequired.
8.3Influenceofpressure
Thesolidparticlemassconcentrationshallberecalculatedtoreferencepressureconditions.
Thesolidparticlemassconcentrationwillvaryindirectproportionintheratioofsystemtosampleabsolutepressure.
8.4Influenceoftemperature
Thesolidparticlemassconcentrationshallberecalculatedtoreferencetemperatureconditions.
Temperaturecouldalsoaffectsolidparticlemeasurementresultsifthetemperatureexceedsthestabilityoftheparticlesmeasuredortheratingofthesamplingequipment.
8.5Averagevalues
Dependingonthereproducibilityofthemethod,themeasurementfacilityandtheexperienceofthepartiesinvolvedintheprovisionofthemeasurementfacility,theaverageofseveralconsecutivemeasurementsatthesamplepointshallbeused.
Theaveragesolidparticlesmassconcentrationcpinmilligramspercubicmetreshallbedeterminedbythe
resultsofnolessthanthreemeasurementsusingtheformula:
(3)
c=
p
cp1t1+cp2t2+...+cpntn
t1+t2+...+tn
where
cp1,cp2,…,cpn
t1,t2,…,tn
arethesolidparticlecontentintheairsamples,inmilligramspercubicmetre;
arethesamplingtimes,inminutes.
9Uncertainty
Theuncertaintyofthemethoddependsontheequipmentusedandtheaccuracyoftheresultcalculation.Thetotaluncertaintyoftheauthorizedresultsofthetestshallbe±10%.
7
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
10Testreport
10.1Statements
StatementsofthesolidparticlemassconcentrationandthemaximumsolidparticlediameterinthecompressedairshallbemadesuchthatthevaluescanbeverifiedinaccordancewiththeproceduresofthispartofISO8573.
Theinfluenceofanyfactors—e.g.oilcontaminantsorsamplepipe—presentinthesamplethatcouldaffecttheresultofparticleconcentrationmeasurementshallberecorded.
10.2Statementformat
ThetestreportusedtodeclaresolidparticlemassconcentrationaccordingtothispartofISO8573shallcontainthefollowing:
a)Adescriptionofthecompressedairsystemanditsworkingconditions,withsufficientdetailforthedeterminationofthevalidityofthedeclaredmassconcentrationvalue:
1)volumeflowrate;
2)samplingtime;
3)pressure;
4)temperature;
5)othercontaminants(includingwaterandoil).
b)Adescriptionofthesamplingpointwherethesamplesweretaken.
c)Adescriptionofthesamplingandmeasurementsystemused,inparticularthematerialsandequipmentused,anddetailsofitscalibrationrecord.
d)Thephrase“DeclaredsolidparticlemassconcentrationinaccordancewithISO8573-8”,followedby
1)thefigurefortheactual,averagemeasuredvalueevaluatedinaccordancewithClause8andcalculatedtorefertothereferenceconditions;
2)thefigurefortheactual,averagemeasuredvalueevaluatedinaccordancewithClause8,referringtotheactualconditions;
3)thesolidparticleconcentration,expressedinmilligramspercubicmetreatactualandreferenceconditions;
4)thepressureandtemperaturetowhichthemeasurementrefers;
5)thefigurefollowedbyastatementregardingtheapplicableuncertainty;and
6)thedateofthecalibrationrecord.
e)Thedateofthesamplingandmeasurements.
AsampletestreportispresentedinAnnexA.
8
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573?8:2004
AnnexA
(informative)
Sampletestreport
Contentofsolidparticlesincompressedairbymassconcentration
Generaldescriptionofcompressedairsystem,testcondition,samplepoint:
____________________________________________________________________________________________
Testmethodapplied:
Samplingmethodapplied:
Listoftestequipmentusedandrespectivecalibrationdates:
____________________________________________________________________________________________
TestresultsofsolidparticlesmassconcentrationinaccordancewithISO8573-8
Test
No.
Testdateandtime
Compressedairparameters
Maximum
solid
particles
diameter
μm
Solidparticlesmassconcentration
mg/m3
Temperature
°C
Pressure
bar(e)
Totalsamplevolume
m3
Actual
condition
Referencecondition
1
2
3
...
...
...
...
Averagevalue:
Reportedby:
Date:
Authorizedby:
Date:
Ifthemeasurementisoutsideaparticularrange,thenidentifyasbeing“notmeasured”.
blank
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO
8573-8:2004
BSI
389ChiswickHighRoadLondon
W44AL
BSI—BritishStandardsInstitution
BSIistheindependentnationalbodyresponsibleforpreparing
BritishStandards.ItpresentstheUKviewonstandardsinEuropeandattheinternationallevel.ItisincorporatedbyRoyalCharter.
Revisions
BritishStandardsareupdatedbyamendmentorrevision.Usersof
BritishStandardsshouldmakesurethattheypossessthelatestamendmentsoreditions.
ItistheconstantaimofBSItoimprovethequalityofourproductsandservices.
Wewould
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 專業(yè)勞務輸出承包協(xié)議范本版B版
- 2024水塔拆除及拆除現(xiàn)場消防安全隱患排查合同3篇
- 2024幼兒園保育員幼兒早期教育與家庭教育合作合同3篇
- 專項粉刷施工合作合同2024版版B版
- 2023-2024學年滬科版(2019)高中信息技術必修二第二單元項目四《探索電子點餐信息系統(tǒng)軟件-了解軟件的功能和開發(fā)》說課稿
- 2024年碎石資源開采與購銷合同協(xié)議書3篇
- 2025彩鋼板復合材料研發(fā)與應用合作協(xié)議3篇
- 11別傷著自己(說課稿)-部編版道德與法治一年級上冊
- 中醫(yī)跟師心得(四氣調神)
- 市第五醫(yī)院醫(yī)學倫理標準操作規(guī)程和審查指南
- 2021傳播心理學課程教學大綱
- 農學技能高考【種植類】復習題庫大全-2、《植物生產與環(huán)境》-下(判斷題)
- 艾瑞咨詢2023年中國脾虛人群白皮書
- 抖音直播電商項目計劃書抖音電商創(chuàng)業(yè)商業(yè)計劃書抖音直播帶貨計劃書抖音電商運營方案
- 26個英文字母描紅字帖
- 部編小學語文單元整體作業(yè)設計三年級下冊第二單元
- TCPQS XF003-2023 滅火器產品維修、更換及售后服務
- htr-pm學習課件18燃耗測量系統(tǒng)
- YY/T 1712-2021采用機器人技術的輔助手術設備和輔助手術系統(tǒng)
- 冀教版三年級下冊數(shù)學全冊教案完整版教學設計
- GB/T 16983-2021化學試劑二氯甲烷
評論
0/150
提交評論