![江西省建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)_第1頁(yè)](http://file4.renrendoc.com/view14/M00/28/01/wKhkGWahDMSAKwolAAD5yBW-Jdo519.jpg)
![江西省建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)_第2頁(yè)](http://file4.renrendoc.com/view14/M00/28/01/wKhkGWahDMSAKwolAAD5yBW-Jdo5192.jpg)
![江西省建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)_第3頁(yè)](http://file4.renrendoc.com/view14/M00/28/01/wKhkGWahDMSAKwolAAD5yBW-Jdo5193.jpg)
![江西省建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)_第4頁(yè)](http://file4.renrendoc.com/view14/M00/28/01/wKhkGWahDMSAKwolAAD5yBW-Jdo5194.jpg)
![江西省建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)_第5頁(yè)](http://file4.renrendoc.com/view14/M00/28/01/wKhkGWahDMSAKwolAAD5yBW-Jdo5195.jpg)
版權(quán)說(shuō)明:本文檔由用戶(hù)提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
PAGEPAGE7江西省工程建設(shè)推薦性標(biāo)準(zhǔn)XXXXXXXXXXXXXXXXXXXXJG贛JG/Txxx-20xx建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)TechnicalstandardforapplicationofSolarheatreflectinginsulationcoatingsforbuildings發(fā)布日期:20xx-xx-xx有效截止日期:xxxx-xx-xx江西省住房和城鄉(xiāng)建設(shè)廳審定發(fā)布江西省工程建設(shè)推薦性技術(shù)標(biāo)準(zhǔn)建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)TechnicalstandardforapplicationofSolarheatreflectinginsulationcoatingsforbuildings贛JG/Txxx-主編單位:江西省建筑科學(xué)研究院批準(zhǔn)部門(mén):江西省住房和城鄉(xiāng)建設(shè)廳施行日期:2021年月日前言根據(jù)江西省住房和城鄉(xiāng)建設(shè)廳《關(guān)于下達(dá)2018年第一批江西省工程建設(shè)標(biāo)準(zhǔn)、建筑標(biāo)準(zhǔn)設(shè)計(jì)編制項(xiàng)目計(jì)劃的通知》(贛建設(shè)[2018]18號(hào))的要求,標(biāo)準(zhǔn)編制組經(jīng)廣泛調(diào)查研究,認(rèn)真總結(jié)實(shí)踐經(jīng)驗(yàn),參考有關(guān)國(guó)內(nèi)先進(jìn)標(biāo)準(zhǔn),并在廣泛征求意見(jiàn)的基礎(chǔ)上,修訂了本標(biāo)準(zhǔn)。本標(biāo)準(zhǔn)的主要技術(shù)內(nèi)容是:1.總則;2.術(shù)語(yǔ);3.基本規(guī)定;4.材料要求;5.設(shè)計(jì);6.施工;7.工程質(zhì)量監(jiān)控及驗(yàn)收。本次修訂的主要技術(shù)內(nèi)容是:1.將規(guī)程適用范圍擴(kuò)展至各類(lèi)民用建筑;2.提出了建筑用反射隔熱涂料的功能性要求指標(biāo);3.調(diào)整了建筑用反射隔熱涂料的等效熱阻取值;4.明確了建筑用反射隔熱涂料熱工設(shè)計(jì)的計(jì)算方法。本標(biāo)準(zhǔn)由江西省住房和城鄉(xiāng)建設(shè)廳歸口管理,由江西省建筑科學(xué)研究院負(fù)責(zé)條文的解釋工作。各單位在執(zhí)行過(guò)程中若有修改意見(jiàn)或建議,請(qǐng)反饋至江西省建筑科學(xué)研究院(地址:南昌市文教路418號(hào),郵編330046),以供今后修訂時(shí)參考。主編單位:江西省建筑科學(xué)研究院參編單位:主要起草人員:主要審查人員:目次TOC\o"1-2"\h\u94401總則 191952術(shù)語(yǔ) 2270813基本規(guī)定 32214材料要求 4113994.1建筑用反射隔熱涂料功能性要求 456394.2建筑用反射隔熱涂料基本性能要求 457575建筑構(gòu)造設(shè)計(jì) 658635.1基本要求 697795.2基本構(gòu)造 6176355.3基層要求 7185706熱工設(shè)計(jì) 936126.1一般規(guī)定 9155526.2隔熱設(shè)計(jì) 981856.3節(jié)能設(shè)計(jì) 985317施工 10294117.1一般規(guī)定 11146647.2施工準(zhǔn)備 11166517.3施工工序 12134108工程質(zhì)量及驗(yàn)收 14102868.1一般規(guī)定 14231108.2主控項(xiàng)目 15303908.3一般項(xiàng)目 1614251附錄A建筑用反射隔熱涂料等效熱阻計(jì)算方法 1726284附錄B建筑用反射隔熱涂料等效熱阻計(jì)算方法 189723附錄C規(guī)范性引用文件 2023882本標(biāo)準(zhǔn)用詞說(shuō)明 21Contents219071GeneralProvisions 1296482Terms 28093GeneralRequirements 3195554MaterialRequirements 4109054.1FunctionalRequirements 4172124.2BasicPerformanceRequirements 4319225ArchitecturalStructureDesign 6119385.1GeneralRequirements 611625.2GeneralConstruction 6275405.3BaseCourseRequirements 7144346ArchitecturalThermalPerformanceDesign 9224356.1GeneralRequirements 916786.2ThermalInsulationDesign 9150326.3EnergyEfficiencyDesign 9262857Construction 10102077.1GeneralRequirements 11311747.2ConstructionPreparations 11219007.3ConstructionSteps 12225178ProjectQualityControlandAcceptance 14125418.1GeneralRequirements 14247798.2MasterControlItems 15198708.3GeneralItems 1619360AppendixACalculationofPollutionCorrectedSolarRadiationAbsorptionCoefficent 176299AppendixBEquivalentThermalResistanceofExternalWallsandRoofingwithArchitecturalReflectiveThermalInsulationCoating 1824408AppendixCNormativeReferenceFiles 2014857DescriptionofRegulationsWords 21PAGEPAGE211總則1.0.1為加強(qiáng)建筑反射隔熱涂料的設(shè)計(jì)、施工質(zhì)量管理,統(tǒng)一建筑反射隔熱涂料施工質(zhì)量驗(yàn)收,提高建筑節(jié)能技術(shù)水平,依據(jù)現(xiàn)行國(guó)家有關(guān)工程質(zhì)量和建筑節(jié)能的法律、法規(guī)、管理要求、相關(guān)技術(shù)標(biāo)準(zhǔn)和我省實(shí)際情況,制定本標(biāo)準(zhǔn)。1.0.2本標(biāo)準(zhǔn)適用于江西省新建、擴(kuò)建、改建的建筑外墻采用建筑用反射隔熱涂料工程的設(shè)計(jì)、施工及質(zhì)量驗(yàn)收。既有民用建筑節(jié)能改造工程可參照?qǐng)?zhí)行。1.0.3建筑用反射隔熱涂料中采用的工程技術(shù)文件、承包合同文件對(duì)工程質(zhì)量的要求不得低于本標(biāo)準(zhǔn)的規(guī)定。1.0.4按照本標(biāo)準(zhǔn)進(jìn)行建筑用反射隔熱涂料建筑節(jié)能工程的設(shè)計(jì)、施工和驗(yàn)收時(shí),除應(yīng)執(zhí)行本標(biāo)準(zhǔn)的規(guī)定外,尚應(yīng)符合現(xiàn)行國(guó)家、行業(yè)和江西省相關(guān)標(biāo)準(zhǔn)規(guī)范的規(guī)定。2術(shù)語(yǔ)2.0.1建筑用反射隔熱涂料Solarheatreflectinginsulationcoatingsforbuildings以合成樹(shù)脂為基料,與功能性顏填料及助劑等配制而成,施涂于建筑物外表面,具有較高太陽(yáng)光反射比、近紅外反射比和半球發(fā)射率的涂料。2.0.2墻面膩?zhàn)觲allputty填嵌墻面基層的孔隙,為涂裝涂料提供符合要求基層的厚漿狀材料。2.0.3底涂層(封閉底漆)bottomcoating對(duì)墻面基層(包括膩?zhàn)訉樱┢鸱忾]作用,并對(duì)基層表面薄弱部分起增強(qiáng)作用的涂層。2.0.4隔熱涂層(建筑反射隔熱涂料面漆)insulationsurfacecoating涂飾工程,具有隔熱、裝飾和保護(hù)功能。2.0.5太陽(yáng)光反射比solarreflectance在300nm~2500nm波段內(nèi)反射與入射的太陽(yáng)輻射通量的比值。2.0.6近紅外反射比nearinfraredreflectance在780nm~2500nm波段內(nèi)反射與入射的太陽(yáng)輻射通量的比值。2.0.7半球發(fā)射率hemisphericalemittance熱輻射體的半球方向上的輻射出射度與處于相同溫度的全輻射體(黑體)的輻射出射度的比值。2.0.8等效熱阻equivalentthermalresistance建筑物的外墻和屋面使用建筑反射隔熱涂料時(shí),與相同條件下采用太陽(yáng)輻射吸收系數(shù)為0.7的普通涂料相比等效增加的熱阻。3基本規(guī)定3.0.1應(yīng)根據(jù)建筑物的特點(diǎn)和使用的涂飾材料,對(duì)建筑物的涂飾面做必要的設(shè)計(jì)及建筑技術(shù)處理。3.0.2采用建筑用反射隔熱涂料的建筑物,其外墻圍護(hù)結(jié)構(gòu)熱工性能應(yīng)符合現(xiàn)行國(guó)家和地方建筑節(jié)能工程相關(guān)標(biāo)準(zhǔn)的規(guī)定。3.0.3建筑用反射隔熱涂料產(chǎn)品進(jìn)入施工現(xiàn)場(chǎng)時(shí),應(yīng)具有中文標(biāo)識(shí)的出廠質(zhì)量合格證、產(chǎn)品出廠檢驗(yàn)報(bào)告、有效期內(nèi)的型式檢驗(yàn)報(bào)告等。3.0.4建筑用反射隔熱涂料應(yīng)符合建筑用外墻有害物質(zhì)限量的要求。3.0.5建筑用反射隔熱涂料具有物理-化學(xué)穩(wěn)定性。所有組成材料應(yīng)彼此相容并具有防腐性。3.0.6在正確使用和正常維護(hù)的條件下,建筑用反射隔熱涂料的使用壽命應(yīng)大于10年。當(dāng)系統(tǒng)的隔熱性能、裝飾性能不能滿足要求時(shí),應(yīng)及時(shí)維修。4材料要求4.0.1建筑用反射隔熱涂料的技術(shù)指標(biāo)應(yīng)符合現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料》JG/T235的有關(guān)規(guī)定,污染后太陽(yáng)光反射比技術(shù)指標(biāo)應(yīng)符合表4.0.1的規(guī)定。表4.0.1污染后的太陽(yáng)光反射比技術(shù)指標(biāo)項(xiàng)目技術(shù)指標(biāo)試驗(yàn)方法污染后太陽(yáng)光反射比外墻屋面現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料》JG/T235≥0.50≥0.604.0.2建筑用反射隔熱涂料使用在金屬屋面時(shí),還應(yīng)符合JG/T375的有關(guān)規(guī)定;使用在其他屋面時(shí),還應(yīng)符合JC/T864的有關(guān)規(guī)定。4.0.3建筑用反射隔熱涂料使用在外墻時(shí),還應(yīng)符合GB/T9755、GB/T9757、JG/T24、JG/T172、HG/T3792或HG/T4104等相應(yīng)產(chǎn)品標(biāo)準(zhǔn)最高等級(jí)要求的有關(guān)規(guī)定。4.0.4建筑用反射隔熱涂料涂飾中配套使用的底漆應(yīng)符合現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑內(nèi)外墻用底漆》JG/T210的有關(guān)規(guī)定。4.0.5建筑用反射隔熱涂料涂飾中配套使用的柔性膩?zhàn)討?yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《外墻柔性膩?zhàn)印稧B/T23455的有關(guān)規(guī)定。5建筑構(gòu)造設(shè)計(jì)5.1基本要求5.1.1采用建筑用反射隔熱涂料的建筑物,其外圍護(hù)結(jié)構(gòu)的熱工性能設(shè)計(jì)應(yīng)符合現(xiàn)行國(guó)家和江西省有關(guān)建筑節(jié)能工程標(biāo)準(zhǔn)的相關(guān)規(guī)定。5.1.2建筑用反射隔熱涂料使用在建筑外墻和屋面,宜結(jié)合建筑造型設(shè)置分隔縫,并應(yīng)采用下列構(gòu)造措施防止雨水沾污墻面:1檐口、窗臺(tái)、線腳等構(gòu)造應(yīng)設(shè)置滴水線(槽);2女兒墻、陽(yáng)臺(tái)欄桿壓頂?shù)捻斆鎽?yīng)有指向內(nèi)側(cè)的泛水坡;3坡屋面檐口應(yīng)超出外墻面。5.1.3應(yīng)根據(jù)建筑隔熱保溫的技術(shù)要求、區(qū)域和自然條件、建筑結(jié)構(gòu)特點(diǎn)、工程使用壽命耐久性要求、維修管理等因素,進(jìn)行多方案的技術(shù)經(jīng)濟(jì)分析,確定最優(yōu)的建筑用反射隔熱涂料應(yīng)用設(shè)計(jì)方案。5.1.4建筑用反射隔熱涂料構(gòu)造應(yīng)包覆門(mén)窗外測(cè)洞口側(cè)面、女兒墻、凸窗側(cè)板以及封閉陽(yáng)臺(tái)等熱橋部位。5.1.5建筑用反射隔熱涂料應(yīng)做好密封和防水構(gòu)造設(shè)計(jì),水平或傾斜的出挑部位以及延伸至地面以下的部位應(yīng)做防水處理。5.2基本構(gòu)造5.2.1外墻反射隔熱涂料飾面的主要構(gòu)造由基層墻體、墻面膩?zhàn)?、底涂層、反射隔熱涂料面漆層及有關(guān)輔助材料組成,具體構(gòu)造見(jiàn)圖5.2.1。圖5.2.1外墻反射隔熱涂料構(gòu)造層次5.2.2外墻反射隔熱涂料與外墻內(nèi)保溫系統(tǒng)組合使用時(shí),其系統(tǒng)構(gòu)造從內(nèi)到外應(yīng)包括外墻內(nèi)保溫層、基層墻體、找平層、墻面、底涂層、隔熱涂料面漆層組成,具體構(gòu)造見(jiàn)圖5.2.2。圖5.2.2外墻反射隔熱涂料及內(nèi)保溫系統(tǒng)構(gòu)造層次5.2.3外墻反射隔熱涂料與外墻外保溫系統(tǒng)組合使用時(shí),可作為外墻外保溫系統(tǒng)的飾面層,其系統(tǒng)構(gòu)造從外到內(nèi)應(yīng)包括反射隔熱涂料面漆層、底涂層、保溫層、找平層、基墻體以及內(nèi)粉刷層組成,具體構(gòu)造見(jiàn)圖5.2.3。圖5.2.3外墻反射隔熱涂料及外保溫系統(tǒng)構(gòu)造層次5.3基層要求5.3.1使用外墻反射隔熱涂料的基層墻體應(yīng)符合以下規(guī)定:1基層應(yīng)牢固、無(wú)開(kāi)裂、掉粉、起砂、空鼓、剝離、爆裂點(diǎn)和附著力不良的舊涂層等。2基層應(yīng)表面平整,立面垂直、陰陽(yáng)角垂直、方正和無(wú)缺棱掉角,分隔縫深淺一致,且橫平豎直,表面應(yīng)平而不光,當(dāng)不滿足要求時(shí)應(yīng)采用強(qiáng)度不低于M5的水泥砂漿找平。3基層應(yīng)清潔、表面無(wú)塵、浮漿、銹斑、霉點(diǎn)和析出鹽類(lèi)等雜物。4基層含水率不應(yīng)大于10%,且不應(yīng)小于或等于8%;pH值不得大于10。5.3.2既有建筑進(jìn)行節(jié)能改造采用建筑反射隔熱涂料時(shí),應(yīng)對(duì)外墻基層進(jìn)行處理,并應(yīng)符合本標(biāo)準(zhǔn)第5.3.1條的規(guī)定。6熱工設(shè)計(jì)6.1一般規(guī)定6.1.1建筑用反射隔熱涂料的熱工設(shè)計(jì)應(yīng)包括隔熱設(shè)計(jì)和節(jié)能設(shè)計(jì)。6.1.2建筑外墻和屋面外飾面采用反射隔熱涂料進(jìn)行隔熱設(shè)計(jì)、節(jié)能設(shè)計(jì)時(shí),應(yīng)采用污染修正后的太陽(yáng)輻射吸收系數(shù)進(jìn)行計(jì)算。6.1.3污染修正后的太陽(yáng)輻射系數(shù)應(yīng)按本標(biāo)準(zhǔn)附錄A計(jì)算。6.1.4建筑用反射隔熱涂料宜選擇淺色產(chǎn)品。6.2隔熱設(shè)計(jì)6.2.1當(dāng)重質(zhì)外墻和屋面使用建筑反射隔熱涂料時(shí),其污染修正后的太陽(yáng)輻射吸收系數(shù)不宜大于0.5當(dāng)輕質(zhì)外墻和屋面使用建筑反射隔熱涂料時(shí),其污染修正后的太陽(yáng)輻射吸收系數(shù)不宜大于0.4。6.2.2隔熱計(jì)算方法應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《民用建筑熱工設(shè)計(jì)規(guī)范》GB50176的有關(guān)規(guī)定。6.3節(jié)能設(shè)計(jì)6.3.1使用建筑反射隔熱涂料的外墻或屋面,可采用規(guī)定性的圍護(hù)結(jié)構(gòu)熱工限值指標(biāo)或節(jié)能綜合指標(biāo)方法進(jìn)行節(jié)能設(shè)計(jì)。6.3.2使用規(guī)定性的圍護(hù)結(jié)構(gòu)熱工限值指標(biāo)進(jìn)行節(jié)能設(shè)計(jì)時(shí),外墻的傳熱系數(shù)應(yīng)采用等效熱阻,并應(yīng)按下式進(jìn)行計(jì)算:式中:K’——外墻使用建筑反射隔熱涂料的傳熱系數(shù)[W/(m2·K)];K——外墻未使用建筑反射隔熱涂料的傳熱系數(shù)[W/(m2·K)];Req——外墻使用建筑反射隔熱涂料的等效熱阻(m2·K/W)。6.3.3建筑外墻的隔熱保溫設(shè)計(jì)應(yīng)符合江西省工程建設(shè)標(biāo)準(zhǔn)《江西省居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》DBJ/T36-024-2014和《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2015等現(xiàn)行相關(guān)標(biāo)準(zhǔn)的要求,建筑用反射隔熱涂料的等效熱阻應(yīng)按本標(biāo)準(zhǔn)表B.0.1.1~B.0.1.7取值。6.3.4當(dāng)采用節(jié)能綜合指標(biāo)方法進(jìn)行節(jié)能設(shè)計(jì)時(shí),應(yīng)采用污染修正后的太陽(yáng)輻射吸收系數(shù)進(jìn)行建筑能耗指標(biāo)計(jì)算。7施工7.1一般規(guī)定7.1.1建筑用反射隔熱涂料工程施工,應(yīng)參照并符合《建筑涂飾工程施工及驗(yàn)收規(guī)程》JGJ/T29中的相應(yīng)規(guī)定。7.1.2建筑用反射隔熱涂料涂飾施工環(huán)境溫度不宜低于5℃,且施工溫度范圍應(yīng)符合產(chǎn)品說(shuō)明書(shū)要求。施工時(shí),空氣相對(duì)濕度不宜大于85%。當(dāng)遇大霧、6級(jí)以上風(fēng)力、雨天時(shí),應(yīng)停止戶(hù)外施工。7.1.3建筑用反射隔熱涂料涂飾施工的安全防護(hù)、勞動(dòng)保護(hù)、防火措施等應(yīng)按國(guó)家現(xiàn)行國(guó)家標(biāo)準(zhǔn)和地方要求的有關(guān)規(guī)定執(zhí)行。7.1.4涂料施工過(guò)程中應(yīng)做好半成品、成品的保護(hù)。7.2施工準(zhǔn)備7.2.1施工單位應(yīng)根據(jù)工程情況、基層條件、設(shè)計(jì)選定樣式、色彩、光澤、材料種類(lèi)、涂飾遍數(shù)、單位用量、作業(yè)平臺(tái)及涂裝機(jī)械等編制涂飾工程施工方案。7.2.2外墻基層應(yīng)通過(guò)驗(yàn)收,并應(yīng)符合本標(biāo)準(zhǔn)第5.3節(jié)的規(guī)定。7.2.3基層表面應(yīng)按下列方式處理:1基層表面應(yīng)清理干凈。當(dāng)基層表面含水率大于10%時(shí),宜晾干至10%以下;當(dāng)基層面含水率小于或等于8%,宜進(jìn)行噴水濕潤(rùn),晾至表面無(wú)水漬后,用外墻界面劑進(jìn)行毛化處理。當(dāng)基層面pH值大于10時(shí),宜用耐水耐堿膩?zhàn)庸瓮糠忾]。2當(dāng)采用外墻外保溫系統(tǒng),基層表面除應(yīng)符合本條第1款的要求外,還宜進(jìn)行抗裂層毛化處理。7.2.4涂飾作業(yè)平臺(tái)應(yīng)符合下列要求:1、應(yīng)符合《建筑施工高處作業(yè)安全技術(shù)規(guī)范》JGJ80的規(guī)定。2、施工面與施工平臺(tái)的距離應(yīng)充分考慮涂料的種類(lèi)、式樣,便于操作。3、按施工高度要求搭設(shè)腳手架。腳手架應(yīng)穩(wěn)定、牢固、可靠。7.2.5建筑涂料所用的材料應(yīng)有產(chǎn)品名稱(chēng)、執(zhí)行標(biāo)準(zhǔn)、種類(lèi)、顏色、生產(chǎn)日期、保質(zhì)期、生產(chǎn)企業(yè)地址、使用說(shuō)明和產(chǎn)品合格證,并具有出廠檢驗(yàn)報(bào)告、有效期內(nèi)的型式檢驗(yàn)報(bào)告。7.2.6施工單位對(duì)涂飾材料的備料和存放應(yīng)符合下列要求:1、應(yīng)根據(jù)選定的品種、工藝要求,結(jié)合實(shí)際面積及材料單位用量和損耗,確定備料量。2、應(yīng)根據(jù)選定的色卡顏色訂貨。超越色卡范圍時(shí),應(yīng)由設(shè)計(jì)者提供顏色樣板,并取得建設(shè)方認(rèn)可后訂貨。3、涂飾涂料應(yīng)存放在專(zhuān)用倉(cāng)庫(kù),并按品種、批號(hào)、顏色分別堆放。專(zhuān)用倉(cāng)庫(kù)應(yīng)陰涼干燥且通風(fēng),溫度在5~40℃之間。7.2.7施工前應(yīng)由施工人員按工序要求做好“樣板”,并保留到竣工。7.2.8涂飾施工前應(yīng)準(zhǔn)備下列合格工具、器具:1、涂刷排筆、盛料桶、天平、磅秤等刷涂及計(jì)量工具。2、羊毛輥筒、海綿輥筒。配套專(zhuān)用輥筒及勻料版等滾涂工具。3、塑料輥筒、鐵質(zhì)壓板滾壓工具。4、無(wú)氣噴涂設(shè)備、空氣壓縮機(jī)、手持噴槍、噴斗、各種規(guī)格口徑的噴嘴、高壓膠管等噴涂機(jī)具。7.2.8大面積涂飾施工前應(yīng)按工序要求做好樣板工程,并應(yīng)保留至竣工。7.3施工工序7.3.1建筑用反射隔熱涂料外墻涂飾施工應(yīng)自上而下進(jìn)行,外墻、屋面施工應(yīng)順同一方向涂飾。施工間歇段的劃分應(yīng)以分隔縫、陰陽(yáng)角為分界線,并應(yīng)做好接茬部位的處理。7.3.2建筑反射隔熱涂料涂飾施工應(yīng)根據(jù)不同基層情況按下列施工工序進(jìn)行:1、非金屬材料基層采用建筑反射隔熱涂料時(shí),涂飾施工的工序?yàn)榛鶎犹幚怼⒐瓮咳嵝阅佔(zhàn)?、涂飾底漆、涂飾建筑反射隔熱涂料?、金屬材料基層采用建筑反射隔熱涂料時(shí),涂飾施工的工序?yàn)榛鶎犹幚?、涂飾底漆、涂飾建筑反射隔熱涂料?.3.3建筑外墻采用內(nèi)保溫系統(tǒng)時(shí),建筑反射隔熱涂料涂飾施工的工序?yàn)閮?nèi)部基層處理、布置保溫層、外部基層處理、刮涂柔性膩?zhàn)?、涂飾底漆、涂飾建筑反射隔熱涂料?.3.4建筑外墻采用外保溫系統(tǒng)時(shí),建筑反射隔熱涂料涂飾施工的工序?yàn)橥獠炕鶎犹幚怼⒉贾帽貙?、刮涂柔性膩?zhàn)?、涂飾底漆、涂飾建筑反射隔熱涂料?.3.5涂飾工程宜按“一底兩面”的要求進(jìn)行施工,后一遍涂飾材料的施工必須在前一遍涂飾材料表面干燥后進(jìn)行;每一遍涂飾材料應(yīng)涂刷均勻,各層涂飾材料必須結(jié)合牢固。對(duì)有特殊要求的工程可增加面漆涂層次數(shù);涂料面漆干膜厚度不應(yīng)小于0.15mm。7.3.6施工過(guò)程中,涂飾材料應(yīng)根據(jù)施工方法、施工季節(jié)、溫度等條件嚴(yán)格控制,并有專(zhuān)人按說(shuō)明書(shū)負(fù)責(zé)調(diào)配,不得隨意加水。配料及操作場(chǎng)所應(yīng)經(jīng)常清理保持整潔,保持良好的通風(fēng)條件。未用完的涂飾材料應(yīng)密封保存,不得泄露或溢出。7.3.7同一墻面同一色彩應(yīng)用相同批號(hào)的涂飾材料,當(dāng)同一顏色批號(hào)不同時(shí),應(yīng)預(yù)先混習(xí),以保證同一墻面不產(chǎn)生色差。7.3.8舊墻面復(fù)涂出新時(shí),應(yīng)清除舊墻面粉化的涂層,鏟除疏松起殼部分,除去殘留的涂膜,視基層特點(diǎn)采用不同的程序施工處理。7.3.9雨期不宜施工,夏季施工時(shí)應(yīng)搭設(shè)防曬布等避免陽(yáng)光暴曬。7.3.10施工過(guò)程中應(yīng)采取措施防止對(duì)周?chē)h(huán)境的污染。7.3.11施工后應(yīng)采取必要的成品保護(hù)措施。8工程質(zhì)量及驗(yàn)收8.1一般規(guī)定8.1.1建筑用反射隔熱涂料質(zhì)量驗(yàn)收應(yīng)按《建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)程》GB50210、《建筑節(jié)能施工質(zhì)量驗(yàn)收規(guī)范》GB50411,《建筑涂飾工程施工及驗(yàn)收規(guī)程》JGJ/T29等現(xiàn)行國(guó)家和江西省有關(guān)標(biāo)準(zhǔn)相關(guān)條款及本標(biāo)準(zhǔn)的驗(yàn)收標(biāo)準(zhǔn)執(zhí)行。8.1.2材料和配套輔件(材)必須符合國(guó)家及江西省現(xiàn)行工程建設(shè)標(biāo)準(zhǔn)、產(chǎn)品標(biāo)準(zhǔn)和設(shè)計(jì)的要求。材料或產(chǎn)品進(jìn)入施工現(xiàn)場(chǎng)時(shí),應(yīng)具有中文標(biāo)識(shí)的出廠質(zhì)量合格證、產(chǎn)品出廠檢驗(yàn)報(bào)告、有效期內(nèi)的型式檢驗(yàn)報(bào)告。8.1.3建筑反射隔熱和反射保溫隔熱涂料施工過(guò)程中應(yīng)及時(shí)進(jìn)行每道工序質(zhì)量檢查、檢驗(yàn)批驗(yàn)收、單位面積用量核查,并留有文字記錄和影像資料。8.1.4驗(yàn)收應(yīng)在建筑反射隔熱涂料飾面層施工質(zhì)量檢查合格后方可進(jìn)行驗(yàn)收,其驗(yàn)收程序和組織應(yīng)遵守現(xiàn)行國(guó)家標(biāo)準(zhǔn)《建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》GB50300的規(guī)定。8.1.5檢驗(yàn)批質(zhì)量驗(yàn)收合格,應(yīng)符合下列規(guī)定:1、檢驗(yàn)批應(yīng)按主控項(xiàng)目和一般項(xiàng)目驗(yàn)收。2、主控項(xiàng)目應(yīng)全部合格。3、一般項(xiàng)目應(yīng)合格;當(dāng)采用計(jì)數(shù)檢驗(yàn)時(shí),至少應(yīng)有90%以上的檢查點(diǎn)合格,且其余檢查點(diǎn)不得有嚴(yán)重缺陷。8.1.6應(yīng)對(duì)反射隔熱涂料附著的圍護(hù)結(jié)構(gòu)基層及其表面處理進(jìn)行隱蔽工程驗(yàn)收,并應(yīng)有詳細(xì)的文字記錄和必要的圖像資料,包括下列內(nèi)容:1.基層表觀情況及其表面處理;2.墻體腳手架眼、孔洞處理;3.膩?zhàn)诱移健?.1.7分項(xiàng)工程質(zhì)量驗(yàn)收合格,應(yīng)符合下列規(guī)定:1、分項(xiàng)工程所含的檢驗(yàn)批均應(yīng)合格。2、分項(xiàng)工程所含的檢驗(yàn)批的質(zhì)量驗(yàn)收記錄應(yīng)完整。8.1.8驗(yàn)收時(shí)應(yīng)核查下列資料:1、設(shè)計(jì)文件、圖紙會(huì)審記錄、設(shè)計(jì)變更和節(jié)能專(zhuān)項(xiàng)審查文件。2、設(shè)計(jì)與施工執(zhí)行標(biāo)準(zhǔn)、文件。3、材料產(chǎn)品質(zhì)量合格證、出廠檢驗(yàn)報(bào)告、有效期內(nèi)的型式檢驗(yàn)報(bào)告符合表4.0.1要求及進(jìn)場(chǎng)驗(yàn)收記錄等。4、檢驗(yàn)批、分項(xiàng)工程驗(yàn)收記錄。5、施工記錄。6、質(zhì)量問(wèn)題處理記錄。7、其他必須提供的資料。8.1.9分項(xiàng)工程驗(yàn)收合格資料應(yīng)匯總到建筑節(jié)能分部工程中。8.2主控項(xiàng)目8.2.1建筑用反射隔熱涂料進(jìn)場(chǎng)后,應(yīng)進(jìn)行質(zhì)量檢查和驗(yàn)收,其品種和性能應(yīng)符合設(shè)計(jì)文件要求和國(guó)家現(xiàn)行標(biāo)準(zhǔn)的有關(guān)規(guī)定。檢驗(yàn)方法:檢查;核查質(zhì)量證明文件。復(fù)檢項(xiàng)目包括:明度值、太陽(yáng)光反射比、污染后太陽(yáng)光反射比、近紅外反射比和半球發(fā)射率。檢查數(shù)量:同廠家、同品種產(chǎn)品,按照扣除門(mén)窗洞口后的墻面面積,在5000m2以?xún)?nèi)時(shí)應(yīng)復(fù)檢1次,每增加5000m2應(yīng)增加1次。同工程項(xiàng)目、同施工單位且同時(shí)施工的多個(gè)單位工程(群體建筑),可合并計(jì)算保溫墻面抽檢面積。8.2.2反射隔熱涂料施工完成后應(yīng)由建設(shè)單位委托對(duì)飾面層進(jìn)行太陽(yáng)光反射比和近紅外反射比現(xiàn)場(chǎng)實(shí)體檢驗(yàn),現(xiàn)場(chǎng)檢測(cè)值不應(yīng)低于設(shè)計(jì)值的90%。檢驗(yàn)方法:應(yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料節(jié)能檢測(cè)標(biāo)準(zhǔn)》JGJ/T287的要求對(duì)建筑用反射隔熱涂料外飾面太陽(yáng)光反射比進(jìn)行現(xiàn)場(chǎng)抽樣檢測(cè)檢查數(shù)量:?jiǎn)挝还こ谈飨蛲鈮Γㄎ菝妫┈F(xiàn)場(chǎng)檢測(cè)抽取不應(yīng)少于3處進(jìn)行檢測(cè)。8.2.3反射隔熱涂料干膜的厚度不應(yīng)小于0.15mm。檢查方法:現(xiàn)場(chǎng)檢查,采用干膜厚度儀測(cè)量。檢查數(shù)量:每個(gè)檢驗(yàn)批抽查不小于3處。8.2.4建筑用反射隔熱涂料的顏色、圖案應(yīng)符合設(shè)計(jì)要求。檢查方法:觀察。檢查數(shù)量:全數(shù)檢查。8.2.5建筑用反射隔熱涂料應(yīng)涂飾均勻、粘結(jié)牢固,不得漏涂、透底、起皮和掉粉。檢查方法:觀察;手摸檢查。檢查數(shù)量:全數(shù)檢查。8.3一般項(xiàng)目8.3.1建筑用反射隔熱涂料層的涂刷質(zhì)量和檢驗(yàn)方法應(yīng)符合表7.3.1的規(guī)定。表8.3.1建筑用反射隔熱涂料層的涂刷質(zhì)量和檢驗(yàn)方法項(xiàng)次項(xiàng)目涂刷質(zhì)量檢驗(yàn)方法1返銹、掉粉、起皮不允許觀察2漏刷、透底不允許觀察3泛堿、咬色不允許觀察4流墜、疙瘩不允許觀察5顏色、刷紋均勻一致、無(wú)刷紋觀察6光澤均勻一致觀察7開(kāi)裂(不包括結(jié)構(gòu)開(kāi)裂引起的涂層開(kāi)裂)不允許觀察8針孔、砂眼無(wú)針孔,無(wú)砂眼觀察9裝飾線、分色線直線度允許偏差(mm)1拉5m線,不足5m拉通線,用鋼直尺檢查8.3.2建筑用反射隔熱涂料層與其他裝修材料和設(shè)備銜接處應(yīng)吻合,界面應(yīng)清晰。檢驗(yàn)方法:觀察。
檢驗(yàn)數(shù)量:全數(shù)檢查。附錄A建筑用反射隔熱涂料污染修正后的太陽(yáng)輻射吸收系數(shù)計(jì)算A.0.1當(dāng)采用污染修正系數(shù)計(jì)算時(shí),污染修正后的太陽(yáng)輻射吸收系數(shù)應(yīng)按下列公式計(jì)算:(A.0.1-1)
(A.0.1-2)(A.0.1-3)式中:—污染修正后的太陽(yáng)輻射吸收系數(shù)?!廴厩巴苛巷椕鎸?shí)驗(yàn)室檢測(cè)的太陽(yáng)光反射比?!廴厩疤?yáng)輻射吸收系數(shù)。—污染修正系數(shù)。A.0.2當(dāng)采用污染后太陽(yáng)光反射比計(jì)算時(shí),污染修正后的太陽(yáng)輻射吸收系數(shù)按下式計(jì)算:(A.0.2)式中:—污染后太陽(yáng)光反射比,按本標(biāo)準(zhǔn)第3.0.1條規(guī)定的試驗(yàn)方法確定。附錄B外墻使用建筑用反射隔熱涂料的等效熱阻B.0.1江西省以下地區(qū)外墻使用建筑用反射隔熱涂料的等效熱阻應(yīng)按表B.0.1~B.0.12取值,其他地區(qū)可按就近原則進(jìn)行選擇。表B.0.1.1南昌市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.10-0.09-0.07-0.05-0.03-0.01東0.510.400.300.210.120.04西0.500.390.290.200.120.04北0.370.290.220.150.090.030.6南-0.06-0.05-0.04-0.03-0.02-0.01東0.330.260.200.140.080.03西0.350.280.210.140.080.03北0.230.190.140.100.060.020.8南-0.04-0.04-0.03-0.02-0.010.00東0.250.190.150.100.060.02西0.270.210.160.110.060.02北0.170.140.100.070.040.011.0南-0.04-0.04-0.03-0.02-0.010.00東0.190.150.120.080.050.02西0.220.170.130.090.050.02北0.130.110.080.060.030.011.2南-0.03-0.02-0.02-0.01-0.010.00東0.160.130.100.070.040.01西0.190.150.110.080.040.01北0.110.090.070.050.030.011.5南-0.02-0.02-0.01-0.01-0.010.00東0.130.100.080.050.030.01西0.150.120.090.060.040.01北0.090.070.050.040.020.01表B.0.1.2九江市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.09-0.08-0.06-0.04-0.03-0.01東0.500.400.300.210.120.04西0.520.410.310.210.120.04北0.360.290.220.150.090.030.6南-0.09-0.08-0.06-0.04-0.03-0.01東0.330.260.190.130.080.03西0.360.280.210.150.080.03北0.230.180.140.100.060.020.8南-0.04-0.04-0.03-0.02-0.010.00東0.240.190.140.100.060.02西0.280.220.160.110.060.02北0.170.140.100.070.040.011.0南-0.03-0.03-0.02-0.02-0.010.00東0.190.150.110.080.050.01西0.220.180.130.090.050.02北0.130.110.080.060.030.011.2南-0.03-0.02-0.02-0.01-0.010.00東0.160.130.090.070.040.01西0.190.150.110.080.040.01北0.110.090.070.050.030.011.5南-0.02-0.02-0.01-0.01-0.010.00東0.130.100.080.050.030.01西0.150.120.090.060.040.01北0.090.070.050.040.020.01表B.0.1.3上饒市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.05-0.04-0.03-0.02-0.010.00東0.900.690.500.340.190.06西0.650.510.380.260.150.05北0.350.280.210.150.090.030.6南-0.01-0.010.000.000.000.00東0.580.440.330.220.130.04西0.400.310.230.160.090.03北0.280.220.170.120.070.020.8南0.000.000.000.000.000.00東0.420.330.240.160.090.03西0.290.230.170.120.070.02北0.230.180.140.090.060.021.0南0.010.010.010.000.000.00東0.340.260.190.130.070.02西0.230.180.130.090.050.02北0.190.150.110.080.050.011.2南0.010.010.010.000.000.00東0.280.210.160.110.060.02西0.180.150.110.070.040.01北0.170.130.100.070.040.011.5南0.010.010.010.000.000.00東0.220.170.130.090.050.02西0.150.110.090.060.030.01北0.140.110.080.060.030.01表B.0.1.4景德鎮(zhèn)市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南0.010.010.010.000.000.00東1.140.860.620.410.230.07西0.740.580.430.290.170.05北0.360.290.220.150.090.030.6南0.030.020.020.010.010.00東0.580.450.330.220.130.04西0.480.370.270.190.110.03北0.240.190.140.100.060.020.8南0.030.020.020.010.010.00東0.380.290.220.150.080.03西0.350.270.200.140.080.03北0.180.140.110.070.040.011.0南0.020.020.020.010.010.00東0.280.220.160.110.060.02西0.280.220.160.110.060.02北0.140.110.090.060.040.011.2南0.020.020.010.010.010.00東0.220.170.130.090.050.02西0.230.180.130.090.050.02北0.120.090.070.050.030.011.5南0.020.020.010.010.010.00東0.160.130.090.070.040.01西0.180.140.100.070.040.01北0.090.080.060.040.020.01表B.0.1.5萍鄉(xiāng)市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.14-0.12-0.09-0.07-0.04-0.01東0.880.670.490.330.190.06西0.880.670.490.330.190.06北0.410.330.250.170.100.030.6南-0.02-0.02-0.01-0.01-0.010.00東0.580.450.330.220.130.04西0.600.460.340.230.130.04北0.280.220.170.120.070.020.8南0.010.010.010.010.000.00東0.440.340.250.170.090.03西0.460.350.260.170.100.03北0.210.170.130.090.050.021.0南0.030.020.020.010.010.00東0.350.270.200.130.080.02西0.370.280.210.140.080.03北0.170.140.100.070.040.011.2南0.030.020.020.010.010.00東0.290.220.160.110.060.02西0.310.240.170.120.070.02北0.140.110.090.060.030.011.5南0.030.020.020.010.010.00東0.230.180.130.090.050.02西0.250.190.140.090.050.02北0.120.090.070.050.030.01表B.0.1.6吉安市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.33-0.28-0.22-0.16-0.10-0.03東0.570.450.340.230.130.04西0.470.370.280.190.110.04北0.270.220.160.120.070.020.6南-0.17-0.14-0.11-0.08-0.05-0.02東0.410.320.240.160.100.03西0.310.240.180.130.070.02北0.170.140.110.070.040.010.8南-0.11-0.09-0.07-0.05-0.03-0.01東0.320.250.190.130.070.02西0.230.180.140.090.050.02北0.130.100.080.050.030.011.0南-0.08-0.06-0.05-0.04-0.02-0.01東0.260.200.150.100.060.02西0.180.140.110.070.040.01北0.100.080.060.040.030.011.2南-0.06-0.05-0.04-0.03-0.02-0.01東0.220.170.130.090.050.02西0.150.120.090.060.040.01北0.080.070.050.040.020.011.5南-0.04-0.04-0.03-0.02-0.010.00東0.180.140.100.070.040.01西0.120.090.070.050.030.01北0.070.050.040.030.020.01表B.0.1.7贛州市外墻使用建筑用反射隔熱涂料的等效熱阻值K(W/m2·K)朝向污染修正后的太陽(yáng)輻射吸收系數(shù)ρc0.20.30.40.50.60.70.4南-0.10-0.08-0.06-0.05-0.03-0.01東0.750.580.430.290.170.05西0.580.460.340.230.140.04北0.520.410.310.210.120.040.6南-0.06-0.05-0.04-0.03-0.02-0.01東0.590.450.330.220.130.04西0.420.330.240.170.100.03北0.330.260.200.140.080.030.8南-0.04-0.03-0.03-0.02-0.010.00東0.470.360.260.180.100.03西0.320.250.190.130.070.02北0.250.200.150.100.060.021.0南-0.03-0.03-0.02-0.01-0.010.00東0.390.300.220.150.080.03西0.260.210.150.100.060.02北0.200.150.120.080.050.021.2南-0.03-0.02-0.02-0.01-0.010.00東0.340.260.190.130.070.02西0.220.170.130.090.050.02北0.160.130.100.070.040.011.5南-0.02-0.02-0.01-0.01-0.010.00東0.280.210.150.100.060.02西0.180.140.100.070.040.01北0.130.100.080.050.030.01附錄C規(guī)范性引用文件下列文件中的條款通過(guò)本標(biāo)準(zhǔn)的引用而成為本標(biāo)準(zhǔn)的條款。凡是注明日期的引用文件,其隨后所有的修改(不包括勘誤的內(nèi)容)或修訂版均不適用于本標(biāo)準(zhǔn),然而,鼓勵(lì)根據(jù)本標(biāo)準(zhǔn)達(dá)成協(xié)議的各方研究是否可使用這些文件的最新版本。凡是不注明日期的引用文件,其最新版本適用于本標(biāo)準(zhǔn)?!督ㄖ梅瓷涓魺嵬苛稀稧B/T25261-2018
《建筑反射隔熱涂料》JGJ/T235-2014
《建筑反射隔熱涂料應(yīng)用技術(shù)規(guī)程》JGJ/T359-2015《建筑涂飾工程施工及驗(yàn)收規(guī)程》JGJ/T29-2015《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411-2019《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2015《江西省居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》DBJ/T36-024-2014《建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)程》GB50210-2018《建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》GB50300-2013《外保溫工程技術(shù)規(guī)程》JGJ144-2008《建筑施工高處作業(yè)安全技術(shù)規(guī)范》JGJ80-2016PAGEPAGE36本標(biāo)準(zhǔn)用詞說(shuō)明為便于在執(zhí)行本標(biāo)準(zhǔn)條文時(shí)區(qū)別對(duì)待,對(duì)要求嚴(yán)格程度不同的用詞說(shuō)明如下:1、表示很?chē)?yán)格,非這樣做不可的。正面詞采用“必須”,反面詞采用“嚴(yán)禁”。2、表示嚴(yán)格,在正常情況下均應(yīng)這樣做的;正面詞采用“應(yīng)”,反面詞采用“不應(yīng)”或“不得”。3表示允許稍有選擇,在條件許可時(shí)首先應(yīng)這樣做的;正面詞采用“宜”或“可”。反面詞采用“不宜”。條文中指明必須按其他有關(guān)標(biāo)準(zhǔn)執(zhí)行的,寫(xiě)法為“應(yīng)按…執(zhí)行”或“應(yīng)符合……的要求(或規(guī)定)”;非必須按指定的標(biāo)準(zhǔn)執(zhí)行的寫(xiě)法為“可參照……的要求(或規(guī)定)”。江西省XXXXXXXXXXXX 建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)Technicalstandardforapplicationofreflectivethermalinsulatingcoatingonbuilding條文說(shuō)明目次TOC\o"1-2"\h\u258331總則 3385084材料要求 3489924.1建筑用反射隔熱涂料功能性要求 34174864.2建筑用反射隔熱涂料基本性能要求 35189155建筑構(gòu)造設(shè)計(jì) 3694045.1基本要求 3673165.2基本構(gòu)造 36313115.3基層要求 36138356熱工設(shè)計(jì) 37220186.1一般規(guī)定 37181186.2隔熱設(shè)計(jì) 37255846.3節(jié)能設(shè)計(jì) 37229847施工 39320437.1一般規(guī)定 39321077.2施工準(zhǔn)備 3945737.3施工工序 39224388工程質(zhì)量及驗(yàn)收 41299228.1基本要求 41106448.2主控項(xiàng)目 4176098.3一般項(xiàng)目 419292附錄B外墻使用建筑用反射隔熱涂料的等效熱阻 421總則1.0.1制定《江西省工程建設(shè)建筑用反射隔熱涂料應(yīng)用技術(shù)標(biāo)準(zhǔn)》。首要目的貫徹落實(shí)國(guó)家建筑節(jié)能要求、《中華人民共和國(guó)促進(jìn)科技成果轉(zhuǎn)化法》、《民用建筑節(jié)能條例》(國(guó)務(wù)院530號(hào))、《建設(shè)領(lǐng)域應(yīng)用新技術(shù)管理規(guī)定》、《建設(shè)部推廣應(yīng)用新技術(shù)管理細(xì)則》。同時(shí)改善居住建筑物室內(nèi)熱環(huán)境;提高我省居住建筑物采暖、空調(diào)降溫能耗使用效率,節(jié)約能源。1.0.2本標(biāo)準(zhǔn)適用于江西省新建居住建筑外墻,采用反射隔熱涂料工程的設(shè)計(jì)、施工、驗(yàn)收及既有建筑節(jié)能改造。4材料要求4.0.1現(xiàn)行建筑反射隔熱涂料的產(chǎn)品標(biāo)準(zhǔn)有《建筑反射隔熱涂料》JG/T235、《建筑用反射隔熱涂料》GB/T25261、《建筑外表面用反射隔熱涂料》JC/T1040。本標(biāo)準(zhǔn)的建筑反射隔熱涂料的性能部分引用了現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料》JG/T235中的相關(guān)規(guī)定。1現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料》JG/T235基本涵蓋了其他兩個(gè)標(biāo)準(zhǔn)的內(nèi)容,標(biāo)準(zhǔn)能夠按照明度不同,規(guī)定了建筑反射隔熱涂料隔熱性能的指標(biāo),同時(shí)針對(duì)不同使用部位的涂料又作出了更具體規(guī)定;2涂料的耐沾污性和耐人工氣候老化性是相當(dāng)重要的,但是國(guó)家標(biāo)準(zhǔn)《建筑用反射隔熱涂料》GB/T25261中對(duì)于耐人工氣候老化性沒(méi)有很好的與涂料的熱工性能相關(guān)聯(lián),而在現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料》JG/T235中對(duì)其污染后的和人工氣候老化后的太陽(yáng)光反射比有做相關(guān)的規(guī)定,能更直觀的反應(yīng)出涂料的耐久性,因此本標(biāo)準(zhǔn)編制組引用了其關(guān)于人工氣候老化后太陽(yáng)光反射比變化率的指標(biāo)要求。3本標(biāo)準(zhǔn)從熱工設(shè)計(jì)角度考慮,對(duì)污染后的太陽(yáng)光反射比提出了更高要求,確保污染后的建筑反射隔熱涂料也能達(dá)到節(jié)能效果。4.0.5膩?zhàn)拥钠焚|(zhì)對(duì)飾面涂層的質(zhì)量影響很大,柔性膩?zhàn)佑懈玫目雇繉娱_(kāi)裂作用,應(yīng)根據(jù)外墻基層情況選用相適應(yīng)的膩?zhàn)赢a(chǎn)品。5建筑構(gòu)造設(shè)計(jì)5.1基本要求5.1.1本條說(shuō)明使用建筑用反射隔熱涂料的外墻熱工設(shè)計(jì)與國(guó)家、行業(yè)和地方建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)的關(guān)系。5.1.2由于涂料墻面容易因砂漿開(kāi)裂受潮引起涂層脫皮、剝落,墻面分格設(shè)計(jì)可以減少抹灰層因面積過(guò)大而產(chǎn)生的龜裂現(xiàn)象,同時(shí)建筑用反射隔熱涂料飾面受到污染時(shí)會(huì)降低其反射性能,故對(duì)采用建筑用反射隔熱涂料飾面應(yīng)采用防止墻面污染的措施。
5.1.3建筑用反射隔熱涂料可與各種類(lèi)型外墻保溫系統(tǒng)組合使用。5.1.4采用建筑用反射隔熱涂料的外墻,應(yīng)保證其防水要求,防止涂層因墻體受潮而起皮、剝落。5.2基本構(gòu)造5.3.1當(dāng)建筑外墻外表面使用反射隔熱涂料時(shí),與采用普通涂料相比,增強(qiáng)了墻體的隔熱保溫性能,該增加的隔熱保溫性能依據(jù)其節(jié)能效果折算為反射隔熱涂料的等效熱阻,等效熱阻計(jì)算,參照江西省空氣溫度等氣候參數(shù)并按GB50176采用,夏季日照輻射按GB50176的80﹪采用,冬季日照輻射按13﹪采用,冬夏季圍護(hù)結(jié)構(gòu)度日數(shù)(能耗)按JGJ134和DB36/J004經(jīng)過(guò)計(jì)算得到外墻反射隔熱涂料的等效熱阻。5.3基層要求5.3.1建筑用反射隔熱涂料涂飾之前應(yīng)先保證基層質(zhì)量及清潔情況,才能保證涂料的涂刷質(zhì)量。水泥砂漿層必須要保證其強(qiáng)度,宜設(shè)置能減少砂漿開(kāi)裂的措施。5.3.2進(jìn)行建筑反射隔熱涂料飾面層的施工之前要保證原有基層的安全牢固,滿足基層應(yīng)有的強(qiáng)度后才能進(jìn)行施工。對(duì)既有建筑舊表面不同基層可采取不同的處理措施,若為非金屬構(gòu)筑物舊涂層墻面,經(jīng)大氣侵蝕出現(xiàn)粉刷層粉化狀況,需鏟除浮灰及已粉化層,將舊墻面清洗,防止舊漆膜成為隔離層,影響涂膜的粘結(jié)力;若為金屬構(gòu)筑物表面舊涂層應(yīng)進(jìn)行除銹及清潔處理;若墻面為舊面磚的,應(yīng)洗刷面磚,消除表面污垢,去除損壞、開(kāi)裂和空鼓的面磚,修補(bǔ)平整后,用柔性膩?zhàn)友a(bǔ)平面磚之間的縫隙。6熱工設(shè)計(jì)6.1一般規(guī)定6.1.1建筑反射隔熱涂料的熱工設(shè)計(jì)應(yīng)包括隔熱設(shè)計(jì)和節(jié)能設(shè)計(jì),圍護(hù)結(jié)構(gòu)節(jié)能設(shè)計(jì)指標(biāo)應(yīng)符合節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)的要求,計(jì)算方法應(yīng)符合節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)的規(guī)定,如《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189、《江西省居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》DBJ/T36-024等。6.1.2由于建筑反射隔熱涂料一般在使用一段時(shí)間后都會(huì)受到一定程度的污染,污染后太陽(yáng)輻射吸收系數(shù)都會(huì)變大,所以在熱工設(shè)計(jì)時(shí),應(yīng)采用污染修正后的太陽(yáng)輻射吸收系數(shù)。6.1.4所謂淺色產(chǎn)品,為涂層明度值不小于80的高明度反射隔熱涂料,具有太陽(yáng)光反射比大,反射太陽(yáng)輻射的能力強(qiáng)的特點(diǎn)。6.2隔熱設(shè)計(jì)6.2.1~6.2.3目前,使用建筑反射隔熱涂料的建筑應(yīng)滿足現(xiàn)行國(guó)家標(biāo)準(zhǔn)《民用熱工設(shè)計(jì)規(guī)范》GB50176的隔熱設(shè)計(jì)要求,由于隔熱計(jì)算是一個(gè)動(dòng)態(tài)的過(guò)程,只能直接帶入污染修正后的太陽(yáng)輻射系數(shù)進(jìn)行計(jì)算。6.3節(jié)能設(shè)計(jì)6.3.1由于建筑節(jié)能設(shè)計(jì)主要有圍護(hù)結(jié)構(gòu)熱工限值指標(biāo)法和性能性指標(biāo)法。圍護(hù)結(jié)構(gòu)熱工限值指標(biāo)法比較簡(jiǎn)單,而性能性指標(biāo)法中的“節(jié)能綜合指標(biāo)”方法,一般采用節(jié)能計(jì)算軟件進(jìn)行計(jì)算。采用了建筑反射隔熱涂料的建筑在進(jìn)行節(jié)能設(shè)計(jì)時(shí),應(yīng)根據(jù)節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)要求,在不滿足規(guī)定性指標(biāo)要求時(shí),采用節(jié)能綜合指標(biāo)法。?6.3.2當(dāng)使用規(guī)定性的圍護(hù)結(jié)構(gòu)熱工限值指標(biāo)進(jìn)行建筑節(jié)能計(jì)算時(shí),采用熱等效熱阻進(jìn)行計(jì)算,才能將反射隔熱涂料的效果反映在圍護(hù)結(jié)構(gòu)的節(jié)能效果中。條文中給出了采用等效熱阻時(shí)的傳熱系數(shù)計(jì)算方法。6.3.3考慮到現(xiàn)行的建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)中對(duì)外墻及屋面的傳熱系數(shù)和熱阻值指標(biāo)進(jìn)行要求,為便于節(jié)能計(jì)算,建筑反射隔熱涂料的節(jié)能效率采用等效熱阻值(由傳熱系數(shù)折減系數(shù)推算)來(lái)表征。由于建筑反射隔熱涂料在夏季有顯著的節(jié)能貢獻(xiàn),而冬季有一定的負(fù)作用,因此,本標(biāo)準(zhǔn)建筑反射隔熱涂料等效熱阻值的取值綜合了考慮冬夏的貢獻(xiàn),使之體現(xiàn)實(shí)際節(jié)能效益。對(duì)應(yīng)用建筑反射隔熱涂料外墻及屋面節(jié)能工程,若采用等效熱阻進(jìn)行進(jìn)行綜合熱工計(jì)算時(shí),則不應(yīng)再采用太陽(yáng)光表面吸收系數(shù)和太陽(yáng)輻照強(qiáng)度修正。6.3.4本條規(guī)定當(dāng)采用“節(jié)能綜合指標(biāo)”方法進(jìn)行建筑節(jié)能設(shè)計(jì)計(jì)算時(shí),需將污染修正后的太陽(yáng)輻射吸收系數(shù)直接代入節(jié)能計(jì)算軟件進(jìn)行計(jì)算,但需要指出的是,圍護(hù)結(jié)構(gòu)不得同時(shí)采用等效熱阻,以避免建筑用反射隔熱涂料效果的重復(fù)計(jì)算。7施工7.1一般規(guī)定7.1.1反射隔熱涂料施工應(yīng)根據(jù)建筑工程情況、涂飾要求、基層條件、施工平臺(tái)及涂裝機(jī)械等編制涂飾工程施工方案,施工人員必須經(jīng)培訓(xùn)合格后方能上崗。7.1.2由于各個(gè)生產(chǎn)廠家的產(chǎn)品不同,其適用的環(huán)境狀況不盡相同,因而涂料在使用時(shí),要按廠家的產(chǎn)品說(shuō)明書(shū)要求進(jìn)行施工。施工溫度是指施工環(huán)境溫度和涂飾基層溫度。根據(jù)經(jīng)驗(yàn)當(dāng)施工環(huán)境相對(duì)濕度大于85%,將不利涂料成膜;由于大風(fēng)、大霧、下雨施工,將妨礙涂膜的養(yǎng)護(hù),因而此時(shí)室外工程應(yīng)停止施工。7.1.3國(guó)家現(xiàn)行標(biāo)準(zhǔn)中有關(guān)勞動(dòng)保護(hù)的標(biāo)準(zhǔn)包括:《涂裝作業(yè)安全規(guī)程涂漆工藝安全及其通風(fēng)凈化》GB6514、《涂裝作業(yè)安全規(guī)程安全管理通則》GB7691及《建筑施工高處作業(yè)安全技術(shù)規(guī)范》JGJ80等。7.2施工準(zhǔn)備7.2.3本條規(guī)定了涂刷建筑反射隔熱涂料的基層處理方式。1非金屬基層表面應(yīng)該進(jìn)行清理,對(duì)含水率、pH值進(jìn)行控制,使基層達(dá)到無(wú)油漬、無(wú)粉塵及干燥要求,目的在于保證飾面層與基層粘結(jié)的牢靠性;在無(wú)陽(yáng)光照射的情況下,可用1lm2大的透明薄膜遮蓋基層表面1h后,檢查其含水率,如薄膜內(nèi)表面顯示有小水珠凝結(jié),則基層面含水率過(guò)大,宜晾干至符合要求;如薄膜內(nèi)表面發(fā)朦,似呈霧狀,則含水率適中;如薄膜內(nèi)表面顯示無(wú)變化,則基層面含水率過(guò)小,宜進(jìn)行噴水濕潤(rùn),晾至表面無(wú)水漬后進(jìn)入下道工序?;鶎颖砻嫠釅A度可用pH試紙檢測(cè)。7.2.8工程涂飾前做好樣板的目的∶一是使操作人員預(yù)先掌握所用材料的特性、配置比例、操作關(guān)鍵等;二是是否符合設(shè)計(jì)要求;三是作為涂飾工程質(zhì)量標(biāo)準(zhǔn)的參照物(標(biāo)準(zhǔn))。對(duì)砂壁狀、復(fù)合涂料在噴涂施工之前,應(yīng)在現(xiàn)場(chǎng)試噴小樣,正常后再上工作面正式施工。7.3施工工序7.3.1涂料施工由自上而下施工,可避免涂飾時(shí)可能發(fā)生的涂料液滴沾污在下面已刷涂完畢的墻面上。對(duì)要求較高的涂飾工程,宜自上而下邊拆腳手架邊完成最后一遍涂飾或采用吊籃施工。分界線作規(guī)定可盡量減少接痕保證質(zhì)量。大面積墻面根據(jù)設(shè)計(jì)要求分格作業(yè),如設(shè)計(jì)未要求分格,則根據(jù)施工經(jīng)驗(yàn)宜按1.5m2左右分格,然后逐格噴涂。劃格條必須選用質(zhì)硬挺拔材料完成。因劃格條的質(zhì)量影響墻面的涂飾質(zhì)量,故不允許抹灰完成后用圖釘劃格的簡(jiǎn)陋做法。7.3.6為保證表面色澤一致,同一幢樓涂飾反射隔熱涂料宜使用同一批號(hào)的。對(duì)同一廠家供應(yīng)的同一色卡、同一品種的涂料,如不同批號(hào),則必須在使用時(shí)倒入大容器內(nèi)混合均勻后才能使用;另外,應(yīng)根據(jù)不同施工方法、季節(jié)、溫度、濕度,控制材料的施工黏度,并確保其黏度一致,以免影響涂料質(zhì)量和涂飾效果。
8工程質(zhì)量及驗(yàn)收8.1基本要求8.1.1建筑用反射隔熱涂料工程在本規(guī)范中既是墻體節(jié)能分項(xiàng)工程,屬建筑節(jié)能分部工程,又是涂飾工程,屬建筑裝飾裝修分部工程。8.1.2材料的經(jīng)常驗(yàn)收是把好材料合格關(guān)的重要環(huán)節(jié)。驗(yàn)收時(shí)應(yīng)對(duì)材料的質(zhì)量證明文件如出廠合格證、出廠檢驗(yàn)報(bào)告及有效期內(nèi)的型式檢驗(yàn)報(bào)告進(jìn)行核查。建筑用反射隔熱涂料質(zhì)量好壞對(duì)建筑節(jié)能的影響較大,應(yīng)實(shí)施抽樣復(fù)檢。8.1.5檢驗(yàn)批的劃分按現(xiàn)行國(guó)家標(biāo)準(zhǔn)《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411的規(guī)定執(zhí)行,原則上與現(xiàn)行國(guó)家標(biāo)準(zhǔn)《建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)范》GB50210也保持一致。主控項(xiàng)目為主要隔熱節(jié)能指標(biāo)必須全部合格。8.2主控項(xiàng)目8.2.1建筑用反射隔熱涂料性能應(yīng)符合本標(biāo)準(zhǔn)中4.1、4.2節(jié)的指標(biāo)要求,其他性能應(yīng)符合下列標(biāo)準(zhǔn)的要求:《合成樹(shù)脂乳液外墻涂料》GB/T09755、《溶劑型外墻涂料》GB/T9757、《彈性建筑涂料》JG/T172、《交聯(lián)型氟樹(shù)脂涂料》HG/T3792、《建筑用水性氟涂料》HG/T4104等。檢查數(shù)量是按現(xiàn)行國(guó)家標(biāo)準(zhǔn)《建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范》GB50411的要求進(jìn)行抽樣。8.2.2建筑用反射隔熱涂料的節(jié)能效果好壞主要取決于涂料飾面的太陽(yáng)光反射比等指標(biāo),本標(biāo)準(zhǔn)第8.2.1條規(guī)定的抽樣復(fù)檢是對(duì)建筑用反射隔熱涂料的材料質(zhì)量進(jìn)行把關(guān),但涂料飾面的形式、現(xiàn)場(chǎng)施工的質(zhì)量、飾面的清潔度等對(duì)飾面的節(jié)能效果同樣有影響,為保證施工后建筑用反射隔熱涂料的節(jié)能實(shí)際效果,應(yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑反射隔熱涂料節(jié)能檢測(cè)標(biāo)準(zhǔn)》JGJ/T287的試驗(yàn)方法對(duì)建筑用反射隔熱涂料外飾面太陽(yáng)光反射比進(jìn)行現(xiàn)場(chǎng)抽樣檢測(cè)。8.3一般項(xiàng)目8.3.1建筑用反射隔熱涂料非隔熱性能工程質(zhì)量的現(xiàn)場(chǎng)核查方法。附錄B外墻使用建筑用反射隔熱涂料的等效熱阻考慮到現(xiàn)行的建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)中外墻的傳熱系數(shù)和熱阻值指標(biāo)進(jìn)行要求,為便于節(jié)能設(shè)計(jì)計(jì)算,建筑用反射隔熱涂料的節(jié)能效率采用等效熱阻值(由傳熱系數(shù)折減系數(shù)推算)來(lái)表征。江西省為夏熱冬冷地區(qū),建筑用反射隔熱涂料在夏季反射太陽(yáng)輻射降低空調(diào)負(fù)荷,有顯著的節(jié)能貢獻(xiàn);而在冬季反射太陽(yáng)輻射增加采暖負(fù)荷,有一定的副作用,因此,建筑用反射隔熱涂料等效熱阻值的取值應(yīng)綜合考慮冬夏的貢獻(xiàn),使之接近實(shí)際節(jié)能效益。本標(biāo)準(zhǔn)提供的等效熱阻計(jì)算參考值是依據(jù)年耗電指數(shù)法得到,年耗電指數(shù)法即通過(guò)采用Dest或DOE全年動(dòng)態(tài)模擬計(jì)算典型建筑能耗隨外墻傳熱系數(shù)K和外墻太陽(yáng)輻射吸收系數(shù)ρc變化的關(guān)系并進(jìn)行擬合計(jì)算,確定能耗與傳熱系數(shù)、太陽(yáng)輻射吸收系數(shù)的變化關(guān)系,即可求出在能耗不變的情況下太陽(yáng)輻射吸收系數(shù)變化量與傳熱系數(shù)變化量之間的等價(jià)關(guān)系,如圖1所示。②③④②③④⑤內(nèi)外①②③④⑤內(nèi)外①a使用普通涂料的墻體b使用反射隔熱涂料的墻體①涂
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 現(xiàn)代產(chǎn)品設(shè)計(jì)中的民族圖案與色彩研究
- 現(xiàn)代紋樣設(shè)計(jì)在商業(yè)品牌推廣中的應(yīng)用實(shí)踐
- 現(xiàn)代辦公環(huán)境下的AI餐廳服務(wù)應(yīng)用研究
- 現(xiàn)代物流行業(yè)的服務(wù)創(chuàng)新與升級(jí)
- 現(xiàn)代辦公環(huán)境下的報(bào)告制作技巧
- 2024年五年級(jí)語(yǔ)文上冊(cè) 第六單元 口語(yǔ)交際:父母之愛(ài)說(shuō)課稿 新人教版
- Module7 Unit2 This little girl can't walk(Period 1) (說(shuō)課稿) -2024-2025學(xué)年外研版(三起)英語(yǔ)五年級(jí)上冊(cè)
- 7《什么比獵豹的速度更快》說(shuō)課稿-2024-2025學(xué)年五年級(jí)上冊(cè)語(yǔ)文統(tǒng)編版001
- 13美麗的冬天 說(shuō)課稿-2024-2025學(xué)年道德與法治一年級(jí)上冊(cè)統(tǒng)編版
- 2024-2025學(xué)年高中化學(xué) 第1章 第4節(jié) 第2課時(shí) 有機(jī)物分子式與分子結(jié)構(gòu)的確定說(shuō)課稿 新人教版選修5
- GB/T 27476.5-2014檢測(cè)實(shí)驗(yàn)室安全第5部分:化學(xué)因素
- 金屬非金屬礦山重大生產(chǎn)安全事故隱患判定標(biāo)準(zhǔn)課件
- 四年級(jí)上冊(cè)數(shù)學(xué)課件-一般應(yīng)用題 全國(guó)通用(共26張PPT)
- 肝臟炎性假瘤的影像學(xué)表現(xiàn)培訓(xùn)課件
- 國(guó)家行政機(jī)關(guān)公文格式課件
- 業(yè)務(wù)員回款考核辦法
- 急性心梗的護(hù)理業(yè)務(wù)學(xué)習(xí)課件
- 2021年投標(biāo)部工作計(jì)劃
- 導(dǎo)向標(biāo)識(shí)系統(tǒng)設(shè)計(jì)(二)課件
- 好書(shū)推薦《西游記》共33張幻燈片
- 化工儀表自動(dòng)化【第四章】自動(dòng)控制儀表
評(píng)論
0/150
提交評(píng)論