1、臨時(shí)用電施工方案一、編制說(shuō)明:本用電方案為1號(hào)建筑物(生活垃圾轉(zhuǎn)運(yùn)車間)工程施工方案的配套技術(shù)方案。本用電方案是根據(jù)施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)程(jgj462005)、建設(shè)工程施工現(xiàn)場(chǎng)供用電安全規(guī)范(gb5010493)及施工具體情況編制。二、工程概況:本工程名稱為1號(hào)建筑物(生活垃圾轉(zhuǎn)運(yùn)車間),位于河北省石家莊市正定縣。本建筑物基底面積為598.2,建筑面積為1525.7。建筑層數(shù)為地上一層,建筑高度14.55m。該工程為框架結(jié)構(gòu),設(shè)計(jì)使用年限為50年,抗震設(shè)防烈度為7度,耐火等級(jí)二級(jí)。本工程需用機(jī)械、電器、電料均已備齊,并已檢修保養(yǎng)完畢,可隨進(jìn)度需要有序進(jìn)場(chǎng)布置。本工程施工機(jī)械及參數(shù)一覽表
2、:序號(hào)供電回路配電箱xddr設(shè)備名稱規(guī)格數(shù)量標(biāo)志功率pkva(kw)1砂漿攪拌機(jī)1套3*1222交流電焊機(jī)bx1500bx13151臺(tái)1臺(tái)40 jc=0.3522.5 jc=0.353平板振動(dòng)器2臺(tái)2.2*24插入式振動(dòng)器zx703臺(tái)1.1*35木工電鋸mj1061臺(tái)5.5633鋼筋切割機(jī)jg-4001套2.2*17鋼筋彎曲機(jī)gw40b1臺(tái)1.38鋼筋切斷機(jī)gt4-141臺(tái)49鋼筋調(diào)直機(jī)gt4-141套410交流電焊機(jī)bx15001臺(tái)4三、配電方式配電原則:總箱配出線采用放射式和樹(shù)干式相結(jié)合的配電方式,對(duì)負(fù)荷比較大的配電點(diǎn)可用單獨(dú)回路配電,對(duì)負(fù)荷較遠(yuǎn)又比較小的配電點(diǎn)上的分箱可采用樹(shù)干式配電方式
3、,總箱中的一路配線先到較近負(fù)荷點(diǎn)的分配電箱,再到較遠(yuǎn)的負(fù)荷點(diǎn)分配電箱,一路線上帶的分配電箱數(shù)量一般為23個(gè),由分配電箱至設(shè)備開(kāi)關(guān)箱配線采用放射式或鏈?zhǔn)脚渚€,對(duì)重要負(fù)荷或較大負(fù)荷采用放射式單路直配,對(duì)較小的負(fù)荷可采用鏈?zhǔn)脚渚€,但每路鏈接設(shè)備不宜超過(guò)5臺(tái),其總?cè)萘坎灰顺^(guò)10kw。本系統(tǒng)總負(fù)荷較大,且有較大單項(xiàng)負(fù)荷何,所以配電方式采用放射式,即總配電箱出線,帶分配電箱,分配電箱放射出線,帶幾個(gè)開(kāi)關(guān)箱。詳見(jiàn)供配電系統(tǒng)圖。四、系統(tǒng)接地方式當(dāng)現(xiàn)場(chǎng)施工設(shè)備供電的變壓器低壓側(cè)為380v220v中性點(diǎn)直接接地時(shí),低壓系統(tǒng)的接地形式必須采用tn-s系統(tǒng),如圖1所示,電器設(shè)備的金屬外殼必須與專用保護(hù)零線(pe線)
4、連接,不得一部分設(shè)備作保護(hù)接零,另一部分設(shè)備作保護(hù)接地,保護(hù)零線不得裝設(shè)開(kāi)關(guān)或熔斷器,保護(hù)零線應(yīng)單獨(dú)設(shè)置,不作它用,重復(fù)接地線應(yīng)與保護(hù)零線相連接。保護(hù)零線使用銅線不少于10mm2,鋁線不少于16mm2,與電氣設(shè)備相連的保護(hù)零線可用不少于6mm2絕緣多股銅線,保護(hù)零線統(tǒng)一標(biāo)志為綠/黃雙色線(以前為黑色),在任何情況下不準(zhǔn)使用綠/黃雙色線作負(fù)荷線。保護(hù)零線除必須在配電室或總配電箱處作重復(fù)接地外,還必須在配電線路的中間處和末端處做重復(fù)接地。重復(fù)接地電阻值不大于1歐,不得用鋁導(dǎo)體做接地體或地下接地線,垂直接地體不宜采用羅紋鋼。垂直接地體應(yīng)采用角鐵、鍍鋅鐵管或圓鋼,長(zhǎng)度1.52.5m,露出地面1015c
5、m,接地線與垂直接地體連接應(yīng)采用焊接或螺紋連接,禁止采用綁扎的方法,施工現(xiàn)場(chǎng)所有用電設(shè)備,除做保護(hù)接零外,必須在設(shè)備負(fù)荷線的首端處設(shè)置漏電保護(hù)裝置。五、漏電開(kāi)關(guān)設(shè)置位置(1)在總箱中,開(kāi)關(guān)的負(fù)荷側(cè)設(shè)漏電保護(hù)器。(2)在設(shè)備的開(kāi)關(guān)箱內(nèi),開(kāi)關(guān)的負(fù)荷側(cè)設(shè)漏電保護(hù)器。六、防雷保護(hù)總配電箱進(jìn)線處和變壓器低壓母線上應(yīng)裝設(shè)低壓避雷器,避雷針長(zhǎng)度12米,可用16圓鋼端部磨尖。避雷針保護(hù)范圍按60遮護(hù)角防護(hù)。七、配電箱選型及安裝位置確定根據(jù)施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范jgj46-2005、j405-2005的要求,總配電箱和分配電箱均應(yīng)裝設(shè)總閘和分路隔離開(kāi)關(guān),總?cè)蹟嗥骱头致啡蹟嗥鳎ɑ蚩傋詣?dòng)開(kāi)關(guān)和分路自動(dòng)開(kāi)關(guān))以
6、及漏電保護(hù)器(若漏電保護(hù)器同時(shí)具備過(guò)負(fù)荷和短路保護(hù)功能,則可不設(shè)分路熔斷器或分路自動(dòng)開(kāi)關(guān))。每臺(tái)設(shè)備應(yīng)有獨(dú)立的開(kāi)關(guān)箱,實(shí)行一機(jī)一閘制,嚴(yán)禁用一個(gè)電器開(kāi)關(guān)直接控制二臺(tái)及二臺(tái)以上用電設(shè)備(含插座)。選擇gjk型施工現(xiàn)場(chǎng)臨時(shí)用電標(biāo)準(zhǔn)配電箱,具體型號(hào)為:1、總配電箱gjk-z3/b型,數(shù)量1臺(tái),2、分配電箱gjk-f6/d型,數(shù)量3臺(tái),3、開(kāi)關(guān)箱gjk-k1/d型,數(shù)量2臺(tái),4、開(kāi)關(guān)箱gjk-4f/c型,數(shù)量1臺(tái),總配電箱應(yīng)設(shè)在靠近電源的地方,分配電箱應(yīng)設(shè)在用電設(shè)備相對(duì)集中的地方,開(kāi)關(guān)箱與分配電箱的距離不得超過(guò)30m,開(kāi)關(guān)箱與被控制的固定式用電設(shè)備距離不得超過(guò)5m。配電箱、開(kāi)關(guān)箱應(yīng)設(shè)在干燥、通風(fēng)及常溫
7、處,不應(yīng)設(shè)在多塵、水霧或有腐蝕性氣體、爆炸危險(xiǎn)的場(chǎng)所以及有劇烈振動(dòng)和地勢(shì)低洼可能積水的場(chǎng)所,否則要采取防護(hù)措施,要避開(kāi)外來(lái)物的沖擊和撞傷。配電箱四周有要有一定的維護(hù)操作距離,即足夠兩人同時(shí)工作的空間或通道。八、主要線路選型及敷設(shè)方式根據(jù)用電負(fù)荷及施工場(chǎng)地平面圖選擇主要供電線路型號(hào)、規(guī)格、長(zhǎng)度,由于本施工現(xiàn)場(chǎng)較小,不作電壓降校驗(yàn)。電纜干線采用地埋敷設(shè),嚴(yán)禁沿地面明設(shè),并應(yīng)避免機(jī)械損傷和介質(zhì)腐蝕,電纜穿越建筑物、道路、易受機(jī)械損傷的場(chǎng)所及引出地面從2m高度至地下0.2m處,須加設(shè)防護(hù)套管,電纜埋地敷設(shè)時(shí),電纜表面距地面不得小于0.6m,且電線上下均勻鋪設(shè)不小于50厚細(xì)砂或軟土,而后再蓋磚保護(hù)。埋地
8、電纜有接頭時(shí),接頭需做在地面上的接線盒中,并能防雨、防塵、防機(jī)械損傷,并遠(yuǎn)離易燃、易爆、易腐蝕場(chǎng)所。九、安全電技術(shù)措施和電氣防火措施1、組織措施(1)項(xiàng)目部設(shè)專人負(fù)責(zé)電氣安全技術(shù)檔案的建立與管理。(2)設(shè)臨電維護(hù)操作電工二名,負(fù)責(zé)填寫(xiě)用電記錄和維護(hù)臨電線路設(shè)備與操作開(kāi)關(guān)。電工必須熟悉用電安全規(guī)程、規(guī)范,并認(rèn)真執(zhí)行。2、線路開(kāi)關(guān)及設(shè)備每月檢查一次,包括線路的絕緣測(cè)試、接地電阻測(cè)試、設(shè)備絕緣測(cè)試及線路設(shè)備完好情況的檢查等。3、根據(jù)施工現(xiàn)場(chǎng)情況,配電系統(tǒng)采用tn-s系統(tǒng),所有用電設(shè)備的外殼必須與專用的pe線相連通,總接地電阻須小于10歐姆。4、手持式用電設(shè)備的保護(hù)地線應(yīng)在移動(dòng)電纜芯內(nèi),其截面必須大于
9、1.5mm2。5、配電箱開(kāi)關(guān)操作順序必須為:送電:總箱分箱開(kāi)關(guān)箱停電:開(kāi)關(guān)箱分箱總箱6、維修和操作開(kāi)關(guān)時(shí),電工必須按規(guī)定穿戴絕緣鞋、手套、必須使用絕緣工具。7、停電1小時(shí)以上時(shí),開(kāi)關(guān)箱、配電箱必須上鎖。8、開(kāi)關(guān)箱內(nèi)不得有雜物,并保持整潔。9、開(kāi)關(guān)的更換、熔斷器熔體的更換嚴(yán)禁用不合格的開(kāi)關(guān)、熔體代。10、現(xiàn)場(chǎng)應(yīng)配備滅火工具、器材,確保電氣設(shè)備及現(xiàn)場(chǎng)其他設(shè)備的安全。確定用電負(fù)荷:(1)、灰漿攪拌機(jī)kx = 0.5 cos = 0.55 tg = 1.52pjs = 0.52.2 = 1.1 kwqjs = pjs tg=1.11.52 = 1.67 kvar(2)、插入式振動(dòng)器kx = 0.3 c
10、os = 0.7 tg = 1.02pjs = 0.30.8 = 0.24 kwqjs = pjs tg=0.241.02 = 0.24 kvar(3)、平板式振動(dòng)器kx = 0.3 cos = 0.7 tg = 1.02pjs = 0.30.5 = 0.15 kwqjs = pjs tg=0.151.02 = 0.15 kvar (4)、鋼筋調(diào)直機(jī)kx = 0.3 cos = 0.7 tg = 1.02pjs = 0.34 = 1.2 kwqjs = pjs tg=1.21.02 = 1.22 kvar(5)、鋼筋切斷機(jī)kx = 0.3 cos = 0.7 tg = 1.02pjs = 0.
11、37 = 2.1 kwqjs = pjs tg=2.11.02 = 2.14 kvar(6)、鋼筋彎曲機(jī)kx = 0.3 cos = 0.7 tg = 1.02pjs = 0.33 = 0.9 kwqjs = pjs tg=0.91.02 = 0.92 kvar(7)、交流電焊機(jī)kx = 0.35 cos = 0.4 tg = 2.29將jc =50%統(tǒng)一換算到j(luò)c1 =100%的額定容量pn = sn cos = 90.4=3.6kwpe = n(jc/jc1)1/2pn = 1(0.5/1)1/23.6 = 2.55 kwpjs = kxpe =0.352.55 = 0.89kwqjs =
12、 pjs tg=0.892.29 = 2.04 kvar(8)、木工圓鋸kx = 0.3 cos = 0.6 tg = 1.33pjs = 0.33 = 0.9 kwqjs = pjs tg=0.91.33 = 1.2 kvar 接地裝置詳圖漏電保護(hù)器保護(hù): 用電線路中采用二級(jí)漏電保護(hù),前級(jí)應(yīng)采用漏電動(dòng)作電流大于50ma,動(dòng)作時(shí)間不大于0.1s的快速動(dòng)作電流型漏電保護(hù)器,末級(jí)應(yīng)采用不大于30ma(潮濕或有腐蝕性介質(zhì)不大于15ma)、動(dòng)作時(shí)間不大于0.1s的漏電保護(hù)器,漏電保護(hù)器在使用過(guò)程中應(yīng)定期由專人檢查,并將檢查結(jié)果記入電工巡檢記錄中,檢查發(fā)現(xiàn)不合格的應(yīng)立即更換。十、電氣設(shè)備的設(shè)置:(1)總
13、配電箱內(nèi)設(shè)600a的空氣開(kāi)關(guān)作隔離開(kāi)關(guān),由其引出7路主干線。(2)配電箱應(yīng)用不小于1.5mm厚的鐵皮制作,箱內(nèi)非絕緣配電板應(yīng)與箱體和pe線可靠連接,進(jìn)出電箱的電線一律由箱體下部開(kāi)口處引入引出,配電板上應(yīng)設(shè)置工作零線(n)接線排和保護(hù)零線接線排(pe),并明確標(biāo)注:n或pe。(3)各配電箱開(kāi)關(guān)箱,應(yīng)安裝端正,作好防雨設(shè)置,固定式電箱下口高1.31.5米,移動(dòng)式電箱下口高0.61.5米,并保證箱前通道暢通、無(wú)雜物。(4)配電箱與開(kāi)關(guān)箱距離不得30米,開(kāi)關(guān)箱與用電設(shè)備距離不得大于3米。十一、電氣設(shè)備操作與維修人員:(1)電工及維修人員必須持證上崗,嚴(yán)禁無(wú)證人員進(jìn)行電氣操作和維修工作。(2)各類用電人
14、員應(yīng)掌握安全用電基本知識(shí)和新用設(shè)備的基本性能。專業(yè)電氣作業(yè)人員應(yīng)佩戴相應(yīng)的勞動(dòng)保護(hù)用品。工作時(shí)發(fā)現(xiàn)問(wèn)題應(yīng)立即排除并向上級(jí)匯報(bào)。(3)嚴(yán)禁設(shè)備帶“病”工作。停用設(shè)備應(yīng)拉閘斷電上鎖。(4)搬運(yùn)設(shè)備必須切斷電源.十二、電氣設(shè)備的使用與維護(hù):(1)配電箱、開(kāi)關(guān)箱應(yīng)每月進(jìn)行一次定期檢查,發(fā)現(xiàn)問(wèn)題及時(shí)維修,維修時(shí)必須將前一級(jí)電箱的相應(yīng)電源開(kāi)關(guān)拉閘斷電,掛停電檢修標(biāo)志,并鎖好或派人看護(hù),嚴(yán)禁帶電作業(yè),對(duì)于漏電保護(hù)器動(dòng)作應(yīng)查明原因,排除故障后,方可再次送電。(2)一般場(chǎng)所的照明電壓為220v,環(huán)境潮濕和易觸的場(chǎng)所照明電壓不大于24v,行燈電壓不大于36v。十三、現(xiàn)場(chǎng)照明1照明器材使用的環(huán)境條件(1) 在正常的
15、空氣相對(duì)濕度時(shí)使用,可選用開(kāi)啟式照明。(2) 在潮濕或特別潮濕的場(chǎng)所,應(yīng)選用密閉型防水防塵照明器材或配有防水燈頭的開(kāi)啟式照明器。十四、避雷針裝置及其安裝1避雷針裝置由避雷針、導(dǎo)(防)雷引下線和接地裝置組成。2腳手架接地處理:在腳手架長(zhǎng)度不超過(guò)50m設(shè)置一接地點(diǎn),接地線采用截面不小于16mm2的鋁導(dǎo)線或截面不小于12mm2的銅導(dǎo)線,做好用焊接,焊接長(zhǎng)度為接地線直徑的6倍以上。十五安全用電措施:1技術(shù)交底制度: 開(kāi)工前應(yīng)由工程科在安全人員的監(jiān)督下,向有關(guān)人員進(jìn)行安全技術(shù)交底,詳細(xì)介紹臨時(shí)用電方案內(nèi)容,安全用電措施和注意事項(xiàng),完畢后履行簽字手續(xù)。2安全檢測(cè)制度:專業(yè)電工在工程技術(shù)人員的指導(dǎo)下對(duì)工作接地、重復(fù)接地、線路絕緣電阻進(jìn)行檢測(cè),以后每月定期檢測(cè),并做好檢測(cè)記錄。漏電保護(hù)器各技術(shù)參數(shù)由公司統(tǒng)一進(jìn)行檢測(cè)和維修,電工應(yīng)定期對(duì)試驗(yàn)按鈕進(jìn)行試驗(yàn),檢查是否動(dòng)作。3電氣維修制度:電氣故障應(yīng)由專人電工進(jìn)行維修,電工應(yīng)以予防為主,加強(qiáng)檢查及時(shí)發(fā)現(xiàn)和消除隱患,并建立維修記錄。4安全用電防火措施: 按總配電圖正確接線。電器電纜應(yīng)按設(shè)計(jì)要求安裝,各電器連接頭應(yīng)壓接牢固。施工現(xiàn)場(chǎng)應(yīng)建立防火檢查制度,加強(qiáng)領(lǐng)導(dǎo),配備相應(yīng)防火器材。使用電焊、氣焊時(shí)要執(zhí)行安全用火制度,并有專人監(jiān)護(hù)。十六、觸電與救護(hù)1人體觸電傷害事故的易發(fā)(1) 在保護(hù)措施不完善的情況下,易發(fā)生人體觸電傷害事故。(2) 施工人員違章操作時(shí)
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二四年度智慧城市建設(shè)新員工入職及城市規(guī)劃合同3篇
- 二零二五版13年物業(yè)管理租賃合同范本解讀2篇
- 買車補(bǔ)充協(xié)議及相關(guān)合同條款(2024版)
- 二零二四全國(guó)獨(dú)家總代理合同含客戶滿意度調(diào)查與服務(wù)3篇
- 大大一班數(shù)學(xué)試卷
- 不同位勢(shì)下擬線性薛定諤方程解的存在性問(wèn)題
- PARP抑制劑對(duì)骨肉瘤X射線-碳離子放療增敏和腫瘤免疫增效的機(jī)制研究
- 五元體系K+,NH4+-Cl-,H2PO4-,(NH2)2CO-H2O共結(jié)晶的研究
- 2025年度贍養(yǎng)老人醫(yī)療費(fèi)用分?jǐn)偧白优?zé)任合同
- 2025版城市配送水泥罐車運(yùn)輸及環(huán)保處理合同3篇
- 乳腺癌的綜合治療及進(jìn)展
- 【大學(xué)課件】基于BGP協(xié)議的IP黑名單分發(fā)系統(tǒng)
- 2025年八省聯(lián)考高考語(yǔ)文試題真題解讀及答案詳解課件
- 信息安全意識(shí)培訓(xùn)課件
- 2024年山東省泰安市初中學(xué)業(yè)水平生物試題含答案
- 美的MBS精益管理體系
- 中國(guó)高血壓防治指南(2024年修訂版)解讀課件
- 2024安全員知識(shí)考試題(全優(yōu))
- 法律訴訟及咨詢服務(wù) 投標(biāo)方案(技術(shù)標(biāo))
- 格式塔心理咨詢理論與實(shí)踐
- 英語(yǔ)六級(jí)詞匯(全)
評(píng)論
0/150
提交評(píng)論